• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 334
  • 16
  • 9
  • 9
  • 9
  • 9
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 359
  • 248
  • 94
  • 80
  • 69
  • 56
  • 54
  • 54
  • 51
  • 51
  • 50
  • 44
  • 43
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Resistência à flexão biaxial, rugosidade e dureza de zircônias monolíticas : efeito da infiltração de sílica pelo método sol-gel e da simulação do desgaste fisiológico /

Alves, Larissa Marcia Martins. January 2016 (has links)
Orientador: Renata Marques de Melo Marinho / Coorientador : Tiago Moreira Bastos Campos / Banca: Tarcísio José de Arruda Paes Júnior / Banca: Frederico dos Reis Goyatá / Resumo: Este estudo avaliou as propriedades mecânicas (resistência à flexão biaxial e dureza) e de superfície (rugosidade) da zircônia monolítica infiltrada com sílica, glazeada, ou polida. Foram confeccionados 198 discos de zircônia (14 mm de diâmetro, 1,2 mm de espessura). As amostras foram polidas com lixas de SiC #1200 e divididas em três grupos principais (n=66). No primeiro, os discos foram infiltrados com sílica, no segundo foram glazeados e no terceiro foram polidos com borrachas abrasivas. Após isso, foram divididos em dois subgrupos (n=33), nos quais somente um de cada tratamento foi submetido a simulação do desgaste fisiológico com esteatitas. Em seguida, as amostras foram submetidas a análises de rugosidade, dureza e ao ensaio de flexão biaxial (ISO 6872) em água. Também foram realizadas análises de difração de raios-X. Os valores de resistência (MPa) foram ranqueados e submetidos a análise de Weibull para cálculo de módulo e resistência característica dos materiais (IC 95%). As amostras também foram analisadas em microscopia eletrônica de varredura para a visualização do desgaste. Os difractrogramas mostraram que os tratamentos, glaze e infiltrado não induziram a transformação de fase, assim como o desgaste, porém o polimento induziu a formação de uma fase cúbica comprimida na superfície. A MEV mostrou as superfícies das amostras, com a formação de estrias nas amostras polidas, silicato de zircônia nas infiltradas e irregularidades nas glazeadas. Também foi possível veri... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the mechanical properties (biaxial flexural strength and hardness) and surface properties (roughness) of infiltrated, glazed or polished monolithic zirconia. 198 zirconia discs were prepared (14 mm diameter, 1,2 mm thickness). The specimens were polished with SiC abrasive paper #1200, and then specimens were divided into three main groups (n=66). In the first, the discs were infiltrated with silica, in the second were glazed and and in third were polished with abrasive rubbers. Thereon, were divided into two subgroups (n=33), in which only one group of each treatment was subjected to wear with steatite, in order to simulate the physiological wear. The specimens were then subjected to roughness analysis, hardness and biaxial bending test (ISO 6872) immersed in water. The groups were evaluated by x-ray diffraction (XRD). The strength values (MPa) were ranked and subjected to Weibull analysis to calculate the Weibull modulus and characteristic strength of the material (CI 95%). The samples were also analyzed by SEM to visualize the wear. In the XRD, it was showed that the treatments did not induce phase transformation as well as wear, however the polishing induced the formation of a compressed cubic phase on the surface. SEM showed the surfaces of the samples with grooves formation on polished, zirconium silicate on infiltrated and irregularities on glazed. It was also possible to verify the removal of surface treatment after simulated wear. The glaze showed... (Complete abstract click electronic access below) / Mestre
142

Avaliação da influência do material obturador na resistência de união de retentor intrarradicular pré-fabricado fixado com resina, em dentes fragilizados, por meio do teste de push-out e MEV / Evaluation of the influence of filling material in the bond strength of a fiber-reinforced post fixed with composite resin in weakened teeth, by push-out test and SEM

Cid Alonso Manicardi 11 March 2010 (has links)
Normalmente, a restauração de dentes tratados endodonticamente e com extensa destruição corono-radicular é um desafio para o clínico. Devido à facilidade de manipulação, resinas compostas fotoativadas têm se apresentado como boa opção para o reforço intrarradicular destes dentes, antes da fixação de pinos. O objetivo desta pesquisa foi avaliar ex vivo a possível interferência de materiais obturadores no reforço interno de raízes fragilizadas restauradas com pinos de fibra e resina composta, por meio do teste de push-out e posterior análise da interface dentina/resina/cimento/pino em microscopia eletrônica de varredura (MEV). Cinquenta caninos superiores tiveram suas coroas removidas e o remanescente dental padronizado em 17 mm de comprimento. Após o preparo mecânico-químico, os espécimes foram distribuídos em um grupo controle (n=10) (preparo normal para pino e sem obturação prévia do canal) e um grupo experimental (n=40). Os espécimes do grupo experimental tiveram suas raízes fragilizadas com brocas diamantadas, de forma a apresentar folga circunferencial de aproximadamente 1,0 mm entre o pino e a estrutura dentinária circundante. Em seguida, os espécimes fragilizados foram redistribuídos em quatro subgrupos (n=10) de acordo com o tipo de material obturador: (G1) Endofill + guta-percha; (G2) AH Plus + guta-percha; (G3) Epiphany + guta-percha; (G4): Epiphany + Resilon. Após 24 h, todos os canais foram preparados em 12 mm. A dentina intrarradicular foi então condicionada com ácido fosfórico a 32% (15s), lavada com água deionizada (30s) e secada com pontas de papel absorvente. A seguir, fina camada de um sistema adesivo de 3 passos (All Bond 2) foi aplicada à dentina com pontas microbrush. Para o reforço das raízes, cada canal foi preenchido com uma resina dual Bis-Core e um pino de fibra (DT Light Post) inserido em toda a extensão do preparo. A fotopolimerização foi feita através do pino por 20 s, com a ponta do fotopolimerizador disposta perpendicularmente a ele. Decorridas 24 h, os espécimes foram seccionados transversalmente em fatias de 1 mm de espessura. A resistência de união foi avaliada por meio do teste de push-out e as falhas observadas em estereomicroscópio. Os espécimes foram avaliados quali-quantitativamente em MEV quanto à interface adesiva, presença de camada híbrida e densidade dos tags. A análise estatística da resistência de união dos materiais, em MPa, após o teste de push-out, revelou diferença entre o grupo controle (15,4 ± 6,91) e os grupos experimentais (GI - 11,41 ± 4,66; GII - 9,97 ± 3,41; GIII - 10,12 ± 4,18; e GIV - 9,0 ± 4,17) (ANOVA, post-hoc Tukey test, p<0,05). Contudo, não houve diferença entre os terços as regiões analisadas dentro de cada grupo (p>0,05). Houve maior ocorrência de falhas adesivas tanto no grupo controle quanto nos experimentais. Em MEV, a análise quantitativa mostrou formação de camada híbrida, tags de resina e ramificações laterais em todas as regiões analisadas. Dentro das limitações do presente estudo, concluiu-se que a obturação prévia do canal radicular reduziu a resistência de união do material de reforço intrarradicular, sem diferença estatística entre os tipos de cimentos testados. / The restoration of endodontically treated teeth commonly presents a challenge in cases of extensive crown-root destruction. Due to their ease of handling, lightactivated composite resins present a better option for intracanal reinforcement before the use of a fiber posts. The aim of this ex vivo study was to evaluate the influence of filling materials in the root reinforcement of weakened experimentally roots restored with composed resin and quartz fiber post by means of push-out bond strength evaluation and scanning electronic microscopy (SEM) analysis of the dentin/resin/cement/post interface. The crowns of 50 upper maxillary canines were removed and the length of roots standardized in 17 mm. After root canal preparation, the specimens were randomly divide into one control (n=10) (normal post preparation with no previous filling) and one experimental groups (n=40). All specimens in the experimental group had their canals enlarged in such a way as to produce a circumferential space of approximately 1.0 mm between the fiber post and the circumjacent dentine walls, using diamond tips. Then, the specimens of the experimental group were subdivided into four subgroups (n=10), according to the filling materials: (G1) Endofill + gutta-percha; (G2) AH Plus + gutta-percha; (G3) Epiphany + gutta-percha; (G4): Epiphany + Resilon. After 24 h of the root canal filling, the canals of all specimens were prepared into 12 mm. The intracanal dentine was etched with 32% phosphoric acid (15s), rinsed with deionised water (30s) and gently dried with absorbent paper points. A 3-step etch-and-rinse adhesive system (All Bond 2) was applied to the slightly moist dentine with disposable microbrush tips. For root reinforcement, each canal was bulk filled with a translucent composite resin (Bis-Core) and a fiber post (DT Light Post) was centrally inserted into the resin mass along the whole post space extension. Light-curing was performed with a conventional device by placing the tip perpendicularly through the post for 20s. After 24 h of the post cementation, the specimens were sectioned perpendicularly to its long axis in 3 slices, with 1 mm of thickness. The bond strength was performed by the push-out test and, after dislodgments, the failures were observed in the stereomicroscope. The specimens were processed for SEM analysis to observe bonding interface formation, hybrid layer quality and resin tag density using a fourstep scale method. The statistical analysis of the bond strength, in MPa, after the push-out test, indicated difference between control (15,4 ± 6,91) and experimental groups (GI - 11.41 ± 4.66; GII - 9.97 ± 3.41; GIII - 10.12 ± 4.18; e GIV - 9.0 ± 4.17) (ANOVA, post-hoc Tukey test, p<0,05), but not between the evaluated regions (p>0.05). The adhesive failures were frequent in the weakened groups as either in the control group. In SEM, the qualitative analysis showed formation of hybrid layer, resin tags and lateral branches in all the analyzed regions, independently of the group. The quantitative analysis (Kruskal-Wallis test, &alpha;=0.05) indicated that previous root canal filling did not influence in the hybrid layer and resin tags formation. Within the limitations of this study, it may be concluded that previous root canal filling have reduced the bond strength in the weakened group, but the type of sealer did not influence in the results.
143

"Estudos do desenvolvimento e caracterização das ligas Cu-Ni-Pt e Cu-Ni-Sn para fins eletro-eletrônicos" / STUDIES OF THE DEVELOPMENT AND CHARACTERIZATION OF THE Cu-Ni-Pt AND Cu-Ni-Sn ALLOYS FOR ELETRO-ELECTRONIC USES

Luis Carlos Elias da Silva 04 October 2006 (has links)
O Cu e suas ligas têm diferentes aplicações na sociedade moderna devido as excelentes propriedades elétricas, condutividade térmica, resistência à corrosão dentre outras propriedades. Estas aplicações podem ser em válvulas, tubulações, panelas para absorção de energia solar, radiadores para automóveis, condutores de corrente e eletrônico, elementos de termostatos e partes estruturais de reatores nucleares, como, por exemplo, bobinas para campo toroidal para um reator de fusão nuclear. Dentre as ligas utilizadas em reatores nucleares, podemos destacar Cu-Be, Cu-Sn e Cu-Pt. O Ni e o Co, freqüentemente são adicionados às ligas de Cu para que a solubilidade seja deslocada para temperaturas mais elevadas com relação aos sistemas binários de Cu-Sn e Cu-Pt. A adição de Ni-Pt ou Ni-Sn ao Cu em porcentagens iguais ou inferiores a 1,5 % aliado a tratamentos termos-mecânico alteram as propriedades do Cu. Estudamos neste trabalho sete diferentes ligas: três ligas de Cu-Ni-Pt 1 (97,99 % Cu - 1,55 % Ni - 0,46 % Pt), 2 (99,33 % Cu - 0,23 % Ni -0,43 % Pt) 3 (98,01 % Cu - 0,48 % Ni - 1,51 % Pt); três ligas de Cu-Ni-Sn 4 (98,31% Cu - 1,12 % Ni - 0,58 % Sn), 5 (98,79 % Cu – 0,57 % Ni - 0,65 % Sn), 6 (98,39% Cu – 0,46 % Ni – 1,16 % Sn) e Cu eletrolítico 0 (0,0058 % Pb - 0,0007 % Fe - 0,0036 % Ni - 0,0024 % Ag). As referentes ligas foram desenvolvidas a partir de um forno a arco voltaico e passaram por tratamentos termo-mecânicos pré-determinados. As microestruturas foram analisadas diretamente por microscopia óptica e microscopia eletrônica de varredura / EDS e indiretamente por medidas de dureza Vickers e condutividade elétrica. O objetivo deste trabalho, portanto, foi observar e constatar os efeitos da mudança da microestrutura em relação às propriedades dureza e condutividade elétrica. / The Cu and its alloys have different applications in the owed modern society the excellent electric properties, thermal conductivity, resistance to the corrosion and other properties. These applications can be in valves, pipes, pots for absorption of solar energy, radiators for automobiles, current driver, electronic driver, thermostats elements and structural parts of nuclear reactors, as, for example, reels for field toroidal for a reactor of nuclear coalition. The alloys used in nuclear reactors, we can highlight Cu-Be, Cu-Sn and Cu-Pt. Ni and Co frequently are added to the Cu alloys so that the solubility is moved for temperatures more elevated with relationship to the binary systems of Cu-Sn and Cu-Pt. The addition of Ni-Pt or Ni-Sn to the Cu in the same or inferior percentages to 1,5% plus thermomechanical treatments changes the properties of the copper. We studied the electric conductivity and hardness Vickers of the Cu-Ni-Pt and Cu-Ni-Sn and compared with the electrolytic Cu. In the proposed flowcharts, breaking of the obtaining of the ingot, we proceeded with thermo mechanical treatments.
144

Avaliação da resistência à corrosão e das propriedades mecânicas da junta soldada de aço inoxidável duplex / Evaluation of the corrosion resistance and the mechanical properties in duplex stainless steel joint

Higa, Silvia Midori 16 December 2015 (has links)
Submitted by Caroline Periotto (carol@ufscar.br) on 2016-09-19T13:35:21Z No. of bitstreams: 1 TeseSMH.pdf: 4755044 bytes, checksum: 3c6412cd47f4445b6a4040b82210ea48 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-20T17:58:01Z (GMT) No. of bitstreams: 1 TeseSMH.pdf: 4755044 bytes, checksum: 3c6412cd47f4445b6a4040b82210ea48 (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-09-20T17:58:12Z (GMT) No. of bitstreams: 1 TeseSMH.pdf: 4755044 bytes, checksum: 3c6412cd47f4445b6a4040b82210ea48 (MD5) / Made available in DSpace on 2016-09-20T17:58:22Z (GMT). No. of bitstreams: 1 TeseSMH.pdf: 4755044 bytes, checksum: 3c6412cd47f4445b6a4040b82210ea48 (MD5) Previous issue date: 2015-12-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / The corrosion resistance and mechanical properties of hardness and toughness of a welded joint multipass duplex stainless steel have been evaluated under the condition with post-weld heat treatment and as-welded. The microstructure along the weld varied as a function of the thermal cycles of the welding process. The heat affected zone (HAZ) showed a higher amount of ferrite and larger grain size. The weld metal (WM) showed more refined microstructure, given by the metal composition of addition used. The parent metal (PM) has not microstructural changes to be far to the fusion zone. The results obtained in electrochemical tests, immersion and mechanical showed that the HAZ presented the pitting potential less noble and higher degree of sensitization in relation to WM and PM. The higher hardness and lower toughness were observed in WM due to the refined microstructure. It was also observed that the post-weld heat treatment reduced the hardness and increased toughness over the joint, reducing the difference of values of these mechanical properties between different regions of the weld. In the corrosion resistance, the effect of the heat treatment was observed in the reduction of the degree of sensitization of the HAZ, it is not significant in pitting potential. The highest rate of corrosion in the welded joint was obtained in the condition as-welded, and observed an attack in the HAZ region. Considering the degree of sensitization and the rate of corrosion of the HAZ, we investigated the presence of precipitates in the region by means of scanning electron microscopy (SEM) and transmission (TEM) with a qualitative chemical analysis and semi-quantitative for energy dispersive X - ray (EDS). The results showed the presence of chi phase, sigma and secondary austenite responsible for the sensitization of the joint as-welded. / A resistência à corrosão e as propriedades mecânicas de dureza e de tenacidade de uma junta soldada multipasses de aço inoxidável duplex foram avaliadas na condição sem e com tratamento térmico pós-soldagem. A microestrutura ao longo da junta soldada variou em função dos ciclos térmicos do processo de soldagem. A zona termicamente afetada (ZTA) apresentou maior quantidade de ferrita e maior tamanho de grão. O metal de solda (MS) apresentou microestrutura mais refinada, dada pela composição do metal de adição utilizado. O metal de base (MB) não sofreu alterações microestruturais por estar distante à zona de fusão. Os resultados obtidos nos ensaios eletroquímicos, de imersão e mecânicos mostraram que a ZTA apresentou o potencial de pites menos nobre e maior grau de sensitização em relação ao MB e ao MS. A maior dureza e menor tenacidade foram observadas no MS em função da microestrutura refinada. Observou-se também que o tratamento térmico pós-soldagem reduziu a dureza e aumentou a tenacidade ao longo da junta, reduzindo a diferença dos valores dessas propriedades mecânicas entre as diferentes regiões da junta soldada. Na resistência à corrosão, o efeito do tratamento térmico foi observado na redução do grau de sensitização da ZTA, não sendo significativo no potencial de pites. A maior taxa de corrosão foi obtida na junta soldada sem tratamento térmico pós-soldagem, sendo observado um ataque na região da ZTA. Considerando o grau de sensitização e a taxa de corrosão da ZTA, investigou-se a presença de precipitados nessa região, por meio de microscopia eletrônica de varredura (MEV) e de transmissão (MET), com análise química qualitativa e semi-quantitativa por energia dispersiva de raios – X (EDX). Os resultados mostraram a presença da fase chi, sigma e austenita secundária, responsáveis pela sensitização da junta sem tratamento térmico pós-soldagem.
145

Ação do peróxido de hidrogênio 35% sobre a morfologia do esmalte e sua interferência do processo des-remineralização: estudo in situ

Arruda, Alex Mendez de [UNESP] 11 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-11Bitstream added on 2014-06-13T18:51:39Z : No. of bitstreams: 1 arruda_am_me_araca.pdf: 646025 bytes, checksum: 136184311e9ba76436388867a2d8dcc5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho analisou in situ o efeito de um clareador a base de peróxido de hidrogênio a 35%, na microdureza superficial em esmalte bovino. Para tanto, 100 fragmentos dentais com dimensões de 4x4x2mm, foram polidos e submetidos à leitura inicial de microdureza Knoop. Foram selecionados os 44 fragmentos com microdureza mais próxima da mediana e estas unidades experimentais foram aleatoriamente divididas em grupos de 4 elementos que foram adaptados a aparelhos moveis usados por 11 indivíduos. Os voluntários foram orientados a utilizar o dispositivo durante todo o dia, com exceção dos momentos destinados à alimentação, higienização e às sessões clareadoras. Metade dos fragmentos de cada dispositivo foi submetida a uma sessão de clareamento (3 aplicações de 15 minutos) por semana, durante 14 dias, totalizando 3 sessões clareadoras. Os fragmentos não clareados permaneceram no dispositivo sem sofrer qualquer tipo de influência do clareador. Durante o uso do aparelho os fragmentos dentais foram submetidos ao acúmulo bacteriano, sendo gotejada uma gota da solução de sacarose a 20% em cada bloco, oito vezes ao dia, visando aumentar o desafio cariogênico. Após 7 dias, do término dos tratamentos foi realizada nova análise da microdureza e os valores foram submetidos à Análise de Variância ao nível de 5%. Pôde-se observar diminuição nos valores de microdureza, tanto para o grupo clareado (média: 238,9 – 179,4), quanto para o grupo controle (média: 237,3 – 191,7), sendo as médias mais baixas encontradas no grupo clareado. Concluiu-se que o tratamento clareador com peróxido de hidrogênio a 35% potencializou a redução da microdureza em dentes submetidos ao desafio cariogênico / This in situ study analyzed the effect of bleaching using 35% hydrogen peroxide on the enamel microhardness. Therefore, 100 dental fragments with dimensions of 4x4x2mm, were polished and subjected to the initial reading of microhardness. We selected 44 fragments presenting microhardness data similar to the mean value and these experimental units were randomly divided into groups of four elements that have been adapted in mobile devices to be worn by 11 volunteers. They were instructed to use the device throughout the day, except in meal times, cleaning and whitening sessions. Bleaching procedures were performed in half of the fragments placed on each device (3 applications of 15 minutes) per week for 14 days, totalizing 3 whitening sessions. Unbleached fragments remained on the device without suffering any kind of influence of the bleaching agent. While using the appliance, dental fragments were lead to bacterial colonization; sine a 20% sucrose solution was dripped eight times a day, aiming to increase the cariogenic challenge. After seven days of the end of the treatment, microhardness \analysis was performed. Data were submitted to ANOVA and Fisher's test at 5%. It was observed a decrease in microhardness values for both bleached group (mean: 238.9 to 179.4) and control group (mean: 237.3 to 191.7), besides that, the lowest values were verified in the bleached groups. It was concluded that bleaching using 35%hydrogen peroxide potentiated the reduction in microhardness in teeth submitted to cariogenic challenge
146

Influência do selante de superfície em propriedades físicas e mecânicas de resinas compostas submetidas a envelhecimentos artificiais

Catelan, Anderson [UNESP] January 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 catelan_a_me_araca.pdf: 509697 bytes, checksum: 775138bff151daa12592bcd4fc83894b (MD5) / O propósito deste estudo foi avaliar a influência do selante de superfície (Biscover LV, Bisco) na microdureza Knoop, rugosidade de superfície e alteração de cor de resinas compostas microhíbridas e nanoparticulada submetidas a envelhecimentos artificiais. Cem espécimes foram confeccionados para cada resina composta, Supreme XT (3M/Espe), Vit-l-escence (Ultradent) e Opallis (FGM). Após 24h, as superfícies das amostras foram polidas e o selante foi aplicado em 50 amostras de cada compósito. A rugosidade de superfície (Ra) foi determinada com um perfilômetro (SJ-400, Mitutoyo) e cut-off de 0,25mm; a microdureza Knoop foi avaliada em um microdurômetro (HMV-2000, Shimadzu), com carga de 50g durante 15s; e a análise cromática inicial foi avaliada de acordo com o sistema CIE L*a*b* em espectrofotômetro de reflexão (UV-2450, Shimadzu). Após as avaliações iniciais, 10 espécimes de cada grupo foram envelhecidos durante 252h em câmara de envelhecimento acelerado de UV (EQUV, Equilam) ou imersos por 4 semanas em uma das três soluções corantes (refrigerante de cola, suco de laranja ou vinho tinto) ou água destilada como controle. Após os envelhecimentos, as propriedades testadas foram re-avaliadas. Os dados de microdureza, rugosidade, alteração de cor foram analisados pela ANOVA e teste de Fischer (α=0,05). Os envelhecimentos artificiais causaram mudanças de cor em todos os grupos e diminuíram os valores de microdureza para todos os materiais, exceto para os compósitos Vit-l-escence e Supreme XT selados, mas não alteraram os valores de rugosidade. O armazenamento em água destilada teve o menor efeito sobre a microdureza e os menores valores de ΔE comparado com os outros processos de envelhecimento (p<0,05). Os materiais selados apresentaram os menores valores de rugosidade e microdureza comparados aos compósitos não selados. Independente do material estudado... / The purpose of this study was to evaluate the influence of surface sealant (Biscover LV, Bisco) on the Knoop microhardness, surface roughness and color alteration of microhybrids and nanofilled composite resins submitted to artificial aging. One hundred specimens were made for each of the composite resins; Supreme XT (3M/Espe), Vit-l-escence (Ultradent) and Opallis (FGM). After 24h, the samples’ surfaces were polished and sealant was applied to 50 samples of each composite. The surface roughness (Ra) was determined using a perfilometer (SJ-400, Mitutoyo) and cut-off of 0.25mm; the Knoop microhardness was evaluated in a microdurometer (HMV-2000, Shimadzu), with 50g load during 15s; and the initial chromatic analysis was evaluated in accordance with CIE L*a*b* system in reflection spectrophotometer (UV-2450, Shimadzu). After the initial evaluations, 10 specimens of each group were aged during 252h in a UV-accelerated aging chamber (EQUV, Equilam) or immersed for 4 weeks in one of three staining solutions (cola soft drink, orange juice or red wine) or distilled water as control. After aging, the properties tested were reevaluated. The microhardness, surface roughness and color alteration data were analyzed by ANOVA and Fischer’s test (α=0.05). The artificial aging caused color changes in all the groups and decreased the microhardness values for all the materials, except for the Vit-l-escence and Supreme XT sealed composites, but had no effect on the roughness values. The storage in distilled water had the least effect on microhardness and resulted in the lowest values of TE compared with other aging processes (p<0.05). The sealed materials presented the lowest values of surface roughness and microhardness compared to the unsealed composites. Regardless of the material studied, the red wine solution demonstrated the highest level of staining (p<0.0001). Intermediate ΔE values were... (Complete abstract click electronic access below)
147

Influência da temperatura sobre a microdureza de uma resina composta fotoativada com luz halógena e Leds

Cáceres Benítez, Pablino [UNESP] 31 August 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-08-31Bitstream added on 2014-06-13T19:51:22Z : No. of bitstreams: 1 caceresbenitez_p_me_arafo.pdf: 539913 bytes, checksum: 4b2674880d3cfaa5af955bceb1ed75eb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo desta pesquisa foi avaliar a influência de várias temperaturas sobre os valores de microdureza de topo e base de uma resina composta fotopolimerizável comercialmente disponível, variando o tipo de fonte de luz (LEDs e lâmpada halógena). As temperaturas testadas foram 25, 35, 45, 55, 65, 80, 90 e 100º C. A resina composta utilizada foi a Z100 (3M). Com o auxílio de uma matriz metálica foram confeccionados 3 corpos-de-prova de 2 mm de espessura e 9,8 mm de diâmetro para cada temperatura. Os corpos-de-prova foram polimerizadas LEDs (60 s) ou lâmpada halógena (40 s) enquanto eram submetidas às diferentes temperaturas, após a polimerização as amostras foram armazenadas a seco, em estufa a 37º C. Após 24 horas as amostras foram submetidas ao teste de microdureza Vickers no topo e na base. Baseados nos resultados conclui-se que com a elevação da temperatura aumentou o valor da dureza Vickers com correlação linear positiva e com ambos aparelhos; o valor da dureza de topo foi sempre superior à dureza de base independentemente da fonte de luz ou temperaturas empregadas; o aparelho de luz halógena só se mostrou superior à fonte de LEDs na região de base dos corpos-de-prova. / The aim of this research was to evaluate the influence of several temperatures on the microhardness values of top and base of a light curing composites resin commercially available, varying the type of light source (LEDs and halogen lamp). The tested temperatures were 25, 35, 45, 55, 65, 80, 90 and 100º C. The composite resin used was Z100 (3M). With the aid of a metallic mould were made three samples of 2 mm of thickness and 9,8 m diameter for each temperature. The samples were light cure while they where submitted to the different temperatures with LEDs (60 s) and halogen lamp (40 s), after the polymerization the samples were dry stored in a stove at 37º C. After 24 hours, the samples were submitted to the Vickers microhardness test in the top and in the base. Based on the results it was concluded that with the elevation of the temperature increased the Vickers hardness value with positive linear correlation on both devices. The hardness value of the top was always superior to the base hardness, independently of the light source or used temperatures. The halogen lamp source was superior to the source of LEDs in the area of base of the samples.
148

Avaliação da dureza e do grau de conversão de uma resina composta em função do pré-tratamento térmico e da fonte de luz fotopolimerizadora

Saade, Esther Gomes [UNESP] 18 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-18Bitstream added on 2014-06-13T20:12:01Z : No. of bitstreams: 1 saade_eg_me_arafo.pdf: 674732 bytes, checksum: 3bfed6ac99e5345683bc3cdd8c9e6925 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse trabalho foi investigar a influência do pré-aquecimento da resina composta anterior à fotopolimerização, sobre suas propriedades físicas e mecânicas como: o grau de conversão e dureza. As amostras foram fotopolimerizadas com uma unidade de luz halógena de quartzo-tungstênio (QTH) e uma unidade diodos emissores de luz azul (LED) por 40 s. Os compules de resina composta híbrida foram pré-aquecidos no dispositivo denominado Calset. A conversão dos monômeros a polímeros foi determinada através do FTIR-ATR. A propriedade de dureza foi avaliada no Microdurômetro MMT-3 Microhardness Tester equipado com o diamante Vickers. Para o teste de dureza Vickers cinco amostras para cada grupo (4 mm de diâmetro e 2 mm de espessura) foram confeccionadas com a resina composta pré-aquecida nas seguintes temperaturas: 37ºC, 54ºC e 60ºC (n=5). As amostras foram submetidas ao teste de dureza Vickers imediatamente após a sua confecção. Foram efetuadas 4 medidas no topo e 4 na base de cada amostra. De acordo com a interação entre as duas unidades de luz e o aumento de temperatura da resina composta, os resultados indicam que somente a unidade de luz influenciou nas médias dos valores de dureza Vickers. A unidade LED apresentou valores de dureza mais homogêneos entre o topo e a base da resina composta, evidenciando uma polimerização mais uniforme. O preaquecimento da resina composta não apresentou diferenças estatisticamente significativas nos valores de dureza. Para a avaliação do grau de conversão foram confeccionadas 5 amostras (4 mm de diâmetro e 2 mm de espessura) para cada grupo, utilizando a unidade QTH e LED, e a resina composta nas seguintes temperaturas: 25ºC (temperatura ambiente), 37ºC, 54ºC e 60ºC (n=40). Após a confecção as amostras foram preparadas para a análise do grau de conversão através do FTIR-ATR. Segundo os resultados conclui-se que não houve diferenças estatisticamente significativas. / The aim of this study was to evaluate the physics and mechanical properties of the pre-heating of the composite resin photo-activated. The samples were photo-activated with a light-curing unit QTH and LED for 40 s. The compules of hybrid composite resin for anterior restorations were pre-heated in the device called “Calset”. The monomer conversion was analyzed using the FTIR-ATR. The hardness property was evaluated with microdurometer MMT-3 equipped with diamond Vickers. Five samples were made for each group (4 mm in diameter and 2 mm in thickness) which the composite resin were pre-heated at temperatures three: 37°, 54° and 60°C. Immediately were submitted to hardness test, which the top and bottom surfaces of the samples took, place an impression for quadrant. According to the interaction between both light-curing units and the increase of the temperature of composite resin, the results showed that only lightcuring unit influenced the hardness average values. The LED light showed a cure homogeneous across the surface of the composite resin and good values of Vickers hardness. The pre-heating of composite resins prior to cure did not show statistically significant differences in the hardness values. For to evaluate the degree of conversion, five samples were made (4 mm in diameter and 2 mm in thickness) for each group using light-curing unit QTH and LED, with the composite resin pre-heated at temperatures of 25ºC (room temperature), 37ºC, 54ºC and 60ºC and analyzed in the spectrophotometer. No significant differences were found in the degree of conversion of the composite resin cured with QTH or LED and to different pre-heating of the composite resin. In this study, any evidence was found that type of light-curing unit used and pre-heating of composite resin could improve the degree of conversion.
149

Clareamento com peróxido de hidrogênio a 35% ativado por diversas fontes de energia: análise térmica e microdureza do esmalte

Kabbach, William [UNESP] 01 April 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-01Bitstream added on 2014-06-13T18:20:14Z : No. of bitstreams: 1 kabbach_w_me_arafo.pdf: 487757 bytes, checksum: 39ad2a660914605ee0e6795c22edba78 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi avaliar in vitro a variação de temperatura e a microdureza Knoop superficial do esmalte durante o processo de clareamento dental com peróxido de hidrogênio a 35% sob irradiação da luz halógena com o comprimento de onda de 400 a 500nm (HL), luz emitida por diodo com comprimento de onda de 460 de 480 (LED) e laser de diodo (DL) de alta intensidade e comprimento de onda de 810nm, em dentes humanos extraídos. Inicialmente investigou-se a variação de temperatura superficial através da termografia de infravermelho e a temperatura do interior da câmara pulpar por meio de termopares em incisivos inferiores humanos, quando submetidos ao clareamento dental com peróxido de hidrogênio a 35% nas cores vermelha (HP) e verde (HPM) irradiados por: HL e LED. Quatro grupos (n=10) foram divididos de acordo com o gel clareador e a fonte de luz. Os resultados foram submetidos à análise de variância e teste de Tukey (p < 0,05). Os valores médios e desvios padrão do aumento de temperatura dentro da câmara pulpar com a HL foram de 4.4 ± 2.1 °C para HP, e 4.5 ± 1.2 °C para HPM; enquanto que nos grupos usando LED, foram 1.4 ± 0.3 °C para HP, e 1.5 ± 0.2 °C para HPM. Para todas as temperaturas superficiais a variação máxima dos grupos irradiados com HL foi 6.5 ± 1.5 °C para HP, e 7.5 ± 1.1 °C usando HPM; enquanto para os grupos usando LED, foram 2.8 ± 0.7 °C usando HP, e 3 ± 0.8 °C para HPM. Não houve diferença estatística entre o aumento da temperatura pulpar e superficial entre os grupos usando os diferentes géis (p < 0,05). As médias de temperatura foram significativamente maiores para os grupos usando HL quando comparados com aqueles irradiados com LED (p < 0,05). Ainda foi investigada a variação de temperatura superficial e assim determinado o tempo de demora para ser atingida a variação crítica de temperatura... / The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using...(Complete abstract, click electronic access below)
150

Monitoramento do fenômeno de queima no processo de retificação de aços por meio de sinais de vibração e análise de tempo e frequência / Grinding burn monitoring of steels by means of vibration signals and time-frequency analysis

Alexandre, Felipe Aparecido 22 January 2018 (has links)
Submitted by FELIPE APARECIDO ALEXANDRE null (felipeapalexandre@hotmail.com) on 2018-02-16T11:26:48Z No. of bitstreams: 1 Dissertação_Felipe_Qualificação (11) _Final.pdf: 5928771 bytes, checksum: 0ce0605e4ba1d5f813dc040262d8115f (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-02-16T18:33:06Z (GMT) No. of bitstreams: 1 alexandre_fa_me_bauru.pdf: 5928771 bytes, checksum: 0ce0605e4ba1d5f813dc040262d8115f (MD5) / Made available in DSpace on 2018-02-16T18:33:06Z (GMT). No. of bitstreams: 1 alexandre_fa_me_bauru.pdf: 5928771 bytes, checksum: 0ce0605e4ba1d5f813dc040262d8115f (MD5) Previous issue date: 2018-01-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os processos de usinagem são de extrema importância para a fabricação de peças mecânicas, muitas das quais exigem alta precisão dimensional e geométrica. A retificação, dentro dos pro-cessos de usinagem, é um processo de acabamento amplamente utilizado na indústria sendo uma das últimas fases na cadeia de usinagem. Devido à sua posição na cadeia de usinagem, é essencial que o processo de retificação seja controlado, visando a detecção e até mesmo a pre-venção de falhas, pois a peça neste estágio possui alto valor agregado. O fenômeno de queima é uma das piores falhas que pode ocorrer na retificação de aços. Desta forma, um sistema de monitoramento capaz de identificar a ocorrência deste fenômeno, além de detectar o momento do início do mesmo, é de grande importância. Nesse contexto, esse trabalho propõe um método para detecção do fenômeno de queima e o momento de sua ocorrência no processo de retifica-ção de aços ABNT 1045 e VC131 com rebolo de óxido de alumínio. Para tal, um acelerômetro foi fixado no suporte das peças e um sensor de potência foi instalado no sistema. Ambos sinais foram amostrados por um osciloscópio a uma taxa de 2 MHz. Técnicas de processamento digital de sinais, tais como a transformada rápida de Fourier (Fast Fourier Transform - FFT), trans-formada de Fourier de tempo-curto (Short Time Fourier Transform -STFT), densidade espectral de potência – (Power Density Spectral - PSD) e índices de danos (RMSD e CCDM) foram aplicadas. Para melhor fundamentar o estudo, testes de dureza, inspeção visual e metalografia foram executados. Os resultados mostram que o método é confiável no que tange a identificação do fenômeno de queima, ou seja, se houve ou não queima na superfície da peça. Em relação a identificação do momento que se inicia a queima na superfície da peça, o método apresenta melhores resultados para o aço ABNT 1045. Assim, estudos complementares devem ser efetu-ados em trabalhos futuros para que o método possa ser estendido para outros materiais com maior acurácia. / The machining processes are of extreme importance for the manufacture of mechanical parts, many of which require high dimensional and geometric precision. Grinding, within the machin-ing processes, is a finishing process widely used in the industry and it is generally the last stage of manufacture chain. Thus, it is essential to control the grinding process, aiming at the detec-tion and even the prevention of failures, since the part in this stage has high added value. The grinding burn is one of the worst failures that can occur in the grinding of steels. In this way, a monitoring system capable of identifying the occurrence of the workpiece burn in addition to detect the onset moment is of great importance. This work proposes a method to detect the workpiece burn and the moment at which it has occurred in grinding of steels SAE 1045 and VC131 with aluminum oxide grinding wheel. An accelerometer was attached to the parts holder and a power sensor was installed in the system. Both signals were acquired by an oscilloscope at a rate of 2 MHz. Digital signal processing techniques such as Fast Fourier Transform (FFT), Short Time Fourier Transform (STFT), Power Density Spectral (PSD) and damage indices (RMSD – root mean square deviation and CCDM – correlation coefficient deviation metric) were applied. To better support the study, hardness tests, visual inspection and metallography were performed. The results show that the method is reliable to identify the burning phenome-non, that is, whether there was grinding burn on the workpiece surface. Regarding the identifi-cation of the grinding burn onset, the method presented better results for the ABNT 1045 steel. Thus, complementary studies should be carried out in future works so that the method can be extended to other materials with greater accuracy.

Page generated in 0.0611 seconds