AMDC : analisador microcontrolado de desfibriladores e cardioversoresPennafiel, Uilson Ruas 12 October 1998 (has links)
Orientação: Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T13:55:29Z (GMT). No. of bitstreams: 1
Pennafiel_UilsonRuas_M.pdf: 6494676 bytes, checksum: 09cddfa5838d480e65df632bfd390aaf (MD5)
Previous issue date: 1998 / Resumo: O funcionamento eficaz e seguro de equipamentos médicos, tais como desfibriladores e cardioversores, requer manutenção preventiva e corretiva que, em muitos casos, precisa ser realizada próximo à unidade hospitalar onde os equipamentos são utilizados. Este trabalho descreve o desenvolvimento de um analisador microcontrolado de desfibriladores e cardioversores, que atende aos requisitos de versatilidade de um instrumento de calibração, a um custo relativamente baixo. O analisador é portátil e auto-suficiente (pode ser alimentado e carrega automaticamente suas baterias) e mede os seguintes parâmetros do pulso desfibrilatório: 1) energia direta e reversa (em 4 escalas, variando de 2 a 1.000J); 2) amplitude máxima de tensão e corrente das parcelas positiva e negativa (até 6 kV); 3) taxas de subida tR, t50 e t10 da norma ANSI/AAMI-DF2 (de 100ms até 200 ms); e 4) duração (de 100ms até 200 ms). A forma de onda do pulso desfibrilatório é apresentada num display tipo LCD de 256x64 pixels e todos os parâmetros aferidos podem ser impressos ou transmitidos a um dispositivo de registro. Uma carga resistiva de entrada (de 25, 50, 75, 100 ou 125 O), selecionada pelo usuário operador, simula a impedância transtorácica do corpo humano. Para testar cardioversores, o analisador simula o complexo QRS ou aguarda um sinal de sincronismo externo para medir o tempo de resposta (atraso entre o sinal de sincronismo e a cardioversão). Ensaios em laboratório com instrumentos calibrados (osciloscópio e geradores) e com destibriladores / cardioversores demonstraram um bom desempenho do protótipo / Abstract: The effectiveness and safety of medical devices, such as defibrillators and cardioverters, require preventive maintenance and repair, which should be carried out in many instances near the hospital unit where the devices are being used. This work describes the development of a microcontrolled analyzer, which fulfills the requirements of a calibrating equipment, at a relatively low cost. The analyzer is powered by batteries, is self-sufficient and measures the following defibrillator output pulse parameters: 1) direct and reverse energy (four ranges, from 2 to 1,000J); 2) direct and reverse peak voltage and current (up to 6 kV); 3) ANSI/AAMI-DF2 tR, t50 and t10 rise rate (from 100ms to 200 ms); and 4) pulse width (from 100ms to 200ms). The defibrillating pulse waveform is shown on a 256x64-pixel LCD display. All measured parameters can be printed or transmitted to a record device. An internal resistive load (of 25, 50, 75, 100 or 125 O) simulates the transthoracic impedance of the human body. To test cardioverters, the analyzer simulates the QRS complex and measures the response time (delay between synchronous and cardioverter pulses). Laboratory tests performed with calibrated instruments (oscilloscope and generators) and field tests with different types of defibrillators have shown good performance of the prototype / Mestrado / Automação / Mestre em Engenharia Elétrica
|
12 |
Efeito sobre o metabolismo lipídico local e sistêmico da eletroestimulação de baixa frequência e da iontoforese dos ativos da curcuma longa em região abdominal / Cíntia Tais Polizer Zanin ; orientador, Percy Nohama, co-orientador ; Eneida Janiscki da LozzoZanin, Cíntia Taís Polizer January 2009 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2009 / Bibliografia: f. 75-87 / A estimulação elétrica de baixa freqüência atua diretamente estimulando a ação
lipolítica, destinada ao tratamento das adiposidades e acúmulos de ácidos graxos
localizados. A iontoforese é uma técnica terapêutica que consiste na administração de
drogas / The low-frequency electrical stimulation operates directly stimulating the lipolytic action,
for the treatment of adiposity and accumulation of fatty acids. The iontophoresis is a
therapeutic technique that consists of the administration of drugs in the
|
13 |
Reabilitação em cães com atrofia muscular induzidaSouza, Soraia Figueiredo de [UNESP] 02 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:08Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-02-02Bitstream added on 2014-06-13T20:01:40Z : No. of bitstreams: 1
souza_sf_dr_jabo.pdf: 2488552 bytes, checksum: d73363ffa31e0435be147582710b8e53 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Avaliou-se a resposta de diferentes protocolos fisioterapêuticos em cães após a indução de atrofia muscular por meio da imobilização do joelho por 30 dias. Os grupos foram denominados grupo C ou controle, grupo M (massagem e movimentação passiva), grupo E (massagem, movimentação passiva e eletroterapia), grupo H (massagem, movimentação passiva e hidroterapia em esteira aquática) e grupo EH (massagem, movimentação passiva, eletroterapia e hidroterapia em esteira aquática). Foram mensurados, os graus de claudicação, amplitude articular, circunferência da coxa, variação sérica das enzimas creatina-quinase e lactato-desidrogenase, bem como a morfometria muscular das fibras de contração rápida e contração lenta do músculo vasto lateral marcadas pela técnica de imunoistoquímica. Os cães do grupo H apresentaram retorno mais precoce à função do membro pélvico direito, mostrando que a hidroterapia pode ser beneficamente empregada para a recuperação em cães claudicantes. A fisioterapia reduziu a contratura articular. Verificou-se maior recuperação da área transversal das fibras musculares de contração lenta e rápida nos cães submetidos à eletroterapia aos 60 dias de pós-operatório. De acordo com os resultados encontrados, foi possível concluir que as modalidades terapêuticas de massagem, movimentação passiva da articulação, estimulação elétrica neuromuscular e hidroterapia por caminhada em esteira aquática aceleram a recuperação clínica em cães com atrofia muscular induzida / The response to different physiotherapeutic protocols was evaluated in dogs with muscle atrophy induced by a 30-day-long immobilization of the stifle joint. The animals were divided in groups namely: C (control), M (massage and passive range of motion), E (massage, passive range of motion and neuromuscular electrical stimulation), H (massage, passive range of motion and hydrotherapy in underwater treadmill), and EH group (massage, passive range of motion, neuromuscular electrical stimulation and hydrotherapy in underwater treadmill). The degree of lameness, range motion, thigh circumference, range of serum creatine kinase (CK) and lactate dehydrogenase (LDH) were then evaluated, as well as the morphometry of fast- and slow-twitch muscle fibers of the vastus lateralis by immunohistochemistry. Group H dogs regained function of the right hind limb faster than the other groups. This result shows that hydrotherapy helped in the recovery process of lame dogs. Physiotherapy reduced the joint contracture. There was a higher recovery rate of cross-sectional area of slow-twitch and fast-twitch muscle fibers and thigh circumference in dogs submitted to neuromuscular electrical stimulation at 60 days post-surgery. According to these results, it was possible to conclude that therapeutics modalities such as massage, passive range of motion of the joint, neuromuscular electrical stimulation and hydrotherapy by walking on underwater treadmill accelerate clinical recovery in dogs with induced muscle atrophy
|
14 |
Efeito da estimulação elétrica de alta voltagem no processo inflamatórioOrtiz, Maria Cristina Sandoval 16 April 2009 (has links)
Made available in DSpace on 2016-06-02T20:18:10Z (GMT). No. of bitstreams: 1
2334.pdf: 2125906 bytes, checksum: c4e6c6beeb6952220467b64ed76dc7d0 (MD5)
Previous issue date: 2009-04-16 / Inflammation is the response of protection of the body to an aggression in order to obtain the healing. This process makes part of many diseases attended by physical therapist, however
when it is increased, limits the fast recovery of the patient. High voltage pulsed current (HVPC) is one of the modalities used to interview of inflammatory process; the type of
stimulation is considered monophasic pulsed that produces a high-driving voltage 150 V, but the total current (average) delivered to the tissue per second does not exceed 1.2 to 1.5mA. There are many studies that evaluate the effect of HVPC in swelling, but the major part was made in animal models and only one in human beings was found in the review of the literature. The results of the studies in animals had showed the effectiveness of HVPC in reduction of edema, but the study in human only showed clinical differences not statistically significant. Additionally, the action mechanism of HVPC is unknown and some hypotheses have been proposed for explaining its effect. The objective of this study was evaluate the effectiveness of HVPC in the inflammation process, both in humans and animals in a submotor level, 100pps of frequency and 45min of treatment. We made a controlled and randomized clinical trial in subjects with lateral sprain of ankle measuring pain, edema, range of mobility and some parameters of the gait comparing three groups: control group (CG) with standard physical therapy, HVPC(-) with standard physical therapy plus HVPC negative polarity and HVPC(+) with standard physical therapy plus HVPC positive polarity. There was not difference between the study groups, but the clinical results suggested that HVPC(-) could contribute to accelerate the recovery of inflammatory process. Second, an experimental study was done in animals evaluating pain, edema, serum histamine and albumin and the cartilage, comparing a control group, a inflammation group with HVPC(-), a inflammation group with HVPC placebo and the last group only with HVPC(-). We did not find differences between the groups in the variables, only observed the lowest cellularity in the cartilage of inflammation group+HVPC(-) and lowest optical density in inflammation group+HVPC
placebo. These results are a contribution for the understanding of the biophysical agent used in the physical therapy, however is necessary more clinical studies including higher sample size, in order to demonstrate the effects of HVPC on the inflammation process. / A inflamação é uma resposta de proteção para livrar o organismo da causa da agressão e de suas conseqüências, para poder alcançar a reparação. Este processo apresenta-se em muitas das enfermidades atendidas pelos fisioterapeutas, mas às vezes sua exacerbação pode limitar a recuperação do sujeito. Uma das formas de tratamento do processo inflamatório é a estimulação elétrica de alta voltagem (EEAV). Este tipo de estimulação é caracterizada por um pulso monofásico pico duplo que gera voltagens superiores a 150V, mas com uma corrente total (média) liberada ao tecido que não excede 1,2 a 1,5mA. Vários estudos foram feitos para avaliar o efeito da EEAV no edema, mas a maioria deles foram realizados em modelos animais, sendo encontrado apenas um estudo em humanos na literatura. Os resultados dos trabalhos em animais têm mostrado a efetividade da EEAV na diminuição do edema contrastando com o estudo em humanos, o qual somente mostrou diferenças clinicas, mas não estatísticas. Adicionalmente, ainda não se conhece o mecanismo de ação da EEAV e têm sido propostas varias hipóteses para explicar este efeito. O objetivo do estudo foi determinar a efetividade da EEAV na inflamação em animais e em humanos utilizando um
nível de amplitude submotor, freqüência de 100pps e 45min de tratamento. Foi feito um ensaio clínico controlado e aleatorizado em sujeitos com entorse lateral de tornozelo
mensurando dor, edema, arco de mobilidade e alguns parâmetros da marcha, comparando três grupos: grupo controle (GC) com fisioterapia convencional; grupo com fisioterapia convencional mais EEAV polaridade negativa e o último grupo com fisioterapia convencional mais EEAV polaridade positiva. Não foram encontradas diferenças estatísticas entre os grupos de estudo, somente diferenças em aspectos clínicos sugerindo uma possível contribuição da EEVA com polaridade negativa na resolução do processo inflamatório. Em uma segunda etapa foi feito um estudo experimental em animais avaliando dor, edema, histamina e albumina séricas e a cartilagem. Os grupos foram: um grupo controle, um inflamado e tratado com EEAV(-), um inflamado e que recebeu EEAV placebo e mais um grupo somente tratado com EEAV(-). Não foram encontradas diferenças entre os grupos nas variáveis mensuradas, mas observou-se menor celularidade na cartilagem dos animais inflamados+EEAV(-) e menor densidade óptica no grupo inflamado+EEVA placebo. Estes resultados são uma contribuição para a validação de um agente biofísico utilizado na fisioterapia, mas precisa-se realizar mais estudos clínicos com amostras maiores para conhecer os reais efeitos da EEAV no processo inflamatório.
|
15 |
Efeitos do campo eletromagnético de 27,12 MHz emitido por equipamento de ondas curtas na espermatogênese de ratos wistar adultosPEDROSA, Márcio Botelho 06 August 2015 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2016-05-20T12:31:27Z
No. of bitstreams: 1
Marcio Botelho Pedrosa.pdf: 1800527 bytes, checksum: 11a367f2109b6bdb35c4c412d6888313 (MD5) / Made available in DSpace on 2016-05-20T12:31:27Z (GMT). No. of bitstreams: 1
Marcio Botelho Pedrosa.pdf: 1800527 bytes, checksum: 11a367f2109b6bdb35c4c412d6888313 (MD5)
Previous issue date: 2015-08-06 / The advancement of technology and the significant increase in radio networks and telecommunications, causes, increasingly, people are exposed and immersed in electromagnetic fields, the effects appear to be controversial and parameter-dependent, and short-term can not represent an imminent risk when applied in a controlled manner, however, as these will behave with the immersion chronic forms in our daily lives is inconclusive and without sufficient studies. On the other hand, the short-wave electromagnetic fields (27.12 MHz) represent an alternative in treatment with electrotherapies for pains and inflammatory processes that affect millions of people worldwide. This work conducted application of short wave field into three groups of Wistar rats divided by daily exposure times of 15, 30 and 60 consecutive days and controls was studied the effects of electromagnetic fields may generate the testes and on spermatogenesis. With such irradiation observed changes primarily on Leydig cells and a variation in testosterone dose between groups, as well as a reduction in long-term prostate weight. Although no alterations in testicular weights and no indication of lesions histopathology with optical microscopy. / O avanço da tecnologia e o aumento significativo das redes de radiofrequências e telecomunicações, faz com que, cada vez mais, as pessoas fiquem expostas e imersas em campos eletromagnéticos, cujos efeitos aparentam ser controversos e parâmetro-dependentes, e a curto prazo podem não representar um risco iminente quando aplicados de forma controlada, no entanto, como estes comportar-se-ão com a imersão de formas crônicas em nosso cotidiano é inconclusivo e sem estudos suficientes. Por outro lado, os campos eletromagnéticos de ondas curtas (27,12 MHz) representam uma alternativa nos tratamentos com eletroterapias para algias e processos inflamatórios, que atingem milhares de pessoas pelo mundo. Este trabalho realizou aplicação do campo de ondas curtas em três grupos de ratos wistar divididos pelos tempos de exposição diário em 15, 30 e 60 dias consecutivos e seus controles, foi estudado os efeitos que os campos eletromagnéticos podem gerar nos testículos e sobre a espermatogênese. Com esta irradiação observou-se mudanças principalmente sobre as células de Leydig e uma variação na dosagem de testosterona entre os grupos, bem como uma diminuição do peso da próstata a longo prazo. Embora não tenham ocorridas alterações nos pesos testiculares e nenhum indicativo de lesões na análise histopatológica com a microscopia óptica.
|
16 |
A corrente aussie apresenta algum efeito na nocicepção e função motora em modelo animal de dor articular inflamatória? / Does aussie current has any effect on nociception and motor function in animal model of inflammatory pain?Silva, Mayara Tavares da 23 February 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / Introduction: Electrical stimulation, a non-pharmacological resource, has been widely used for pain relief. The aussie current has presented analgesic potential effect, however, its form of action is still hypothetical. Objective: to evaluate the effect of aussie current on nociception and motor behavior in an animal model of inflammatory joint pain. Methods: 36 male Wistar rats were used and the inflammation was induced in the knee by intra-articular injection of a mixture of 3% carrageenan and 3% kaolin. The animals, randomly distributed, were separated into six groups: four groups were treated with aussie current with high or low intensity combined with high or low frequency, burst duration of 4 ms and burst frequency of 50 Hz for 20 minutes; negative control group was remained anesthetized during this same period and the positive one was treated with morphine (5 mg/kg), each group consisting of 6 animals. Primary, secondary and thermalv hiperalgesy, as well as the exploratory locomotor activity of the animals were evaluated. A single investigator performed all assessments, in addition to being masked, and the therapist did not interfere in the assessments. The results were expressed as mean ± SEM. Differences between the groups were related by the two-way ANOVA with the post hoc Tukey test. Values of p <0.05 were considered significant. Results: There was a significant reduction of the deep mechanical threshold 24 hours after induction of inflammation when compared to baseline in all groups (p <0.002). No significant differences were observed in the post-treatment evaluations with the aussie current at moments 0h, 2h, 4h, 6h immediately after the first application and after repeated applications for five consecutive days, only the morphine treated group presented reduction of hyperalgesia (p <0.02). Conclusion: the aussie current did not show antinoceptive effect in animal model of inflammatory pain. / Introdução: A estimulação elétrica, um recurso não-farmacológico, tem sido bastante utilizada para alívio da dor. A corrente aussie tem apresentado potencial efeito analgésico, porém, sua forma de ação tem sido pouco estudada. Objetivo: Avaliar o possível efeito da corrente aussie na nocicepção e no comportamento motor em modelo animal de dor articular inflamatória. Métodos: Foram utilizados 36 ratos Wistar machos e a inflamação foi induzida no joelho pela injeção intra-articular de uma mistura de 3% de carragenina e 3% de caolina. Os animais, distribuídos aleatoriamente, foram separados em seis grupos: quatro grupos tratados com a corrente aussie com alta ou baixa intensidade combinada com alta ou baixa frequência, duração de burst de 4 ms e a frequência em burst de 50 Hz, durante 20 minutos; grupo controle negativo que permaneceu anestesiado durante esse mesmo período e o positivo tratado com morfina (5 mg/kg) sendo cada grupo composto por 6 animais. Foram avaliadas hiperalgesia primária, secundária e térmica, além da atividade locomotora exploratória dos animais. Um único pesquisador realizou todas as avaliações, além de ter sido mascarado, e o aplicador da terapia não interferiu nas avaliações. Os resultados foram expressos em média +/- EPM. Diferenças entre os grupos foram analisadas pela ANOVA de duas vias com o teste post hoc de Tukey. Valores de p<0,05 foram considerados significativos. Resultados: Houve redução significativa do limiar mecânico profundo 24 horas após indução da inflamação quando comparado ao momento basal em todos os grupos (p<0,002). Não foram observadas diferenças significativas nas avaliações de hiperalgesia primária, secundária e térmica, nem da atividade locomotora exploratória pós-tratamento com a corrente aussie nos momentos 0, 2, 4 e 6 h imediatamente após a primeira aplicação e após aplicações repetidas por cinco dias consecutivos, apenas o grupo tratado com morfina apresentou redução dessas variáveis avaliadas. Conclusão: A corrente aussie não mostrou efeito antinoceptivo em modelo animal de dor inflamatória. / Aracaju
|
17 |
Efeito de eletroestimulação sobre o processo de reparo de cavidade ossea cirurgica, com ou sem enxerto osseo. Estudo histologico em calvaria de coelhoSilva, Claudia Jordão 02 December 1996 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T20:50:26Z (GMT). No. of bitstreams: 1
Silva_ClaudiaJordao_M.pdf: 4090867 bytes, checksum: bfd1ff3ed0e4830528fe82ad6f674596 (MD5)
Previous issue date: 1996 / Resumo: O propósito deste trabalho foi avaliar histologicamente o processo de reparo de defeitos ósseos, criados cirurgicamente em calvária de coelho, com ou sem enxerto ósseo e submetidos ou não a eletroestimulação. Foram utilizados 18 coelhos, sendo que cada um deles recebeu duas osteotomias na calvária. Na osteotomia do osso parietal direito o fragmento removido foi imediatamente reposicionado, sendo que no parietal esquerdo o fragmento foi desprezado. Os animais dos grupos tratados receberam a eletroestimulação por uma hora, durante 21 dias. Já os animais do grupo controle foram submetidos as mesmas condições de stress, porém com o aparelho desligado. Os períodos de sacrifício foram as quatro, oito e quinze semanas, compreendendo seis animais sacrificados em cada período. A análise dos espécimes sob a microscopia óptica revelou neoformação óssea em todos os animais. Nos animais com enxerto ósseo houve uma reparação mais acentuada quando comparados com o grupo sem enxerto. A eletroestimulação parece ter alterado o processo de reparo ósseo de maneira discreta / Abstract: The purpose of this research was to histologicalIy evaluate the healing process in bone defects surgically created in calvaria of rabbits, with or without bone grafts under the action of eletrotherapy or not. It were utilized 18 rabbits with 2 perfurations in each calvaria. In the right parietal bone perforation the fragment removed was immediately grafted in its place. lu the left parietal bone the fragment was thrown away. The animais in the treated group received 1 hour of eletrotherapy dayly, during 21 days. The animals in the control group were submitted to the same stress conditions, but the stimulator was turned off. The sacrifice periods were 4, 7 and 15 weeks, with 6 sacrificed animais in each group. The analysis of the specimens under optical microscopy revealed bone formation in all animals. In the animals with the bone grafted there was a more noticeable healing when compared to the animais in the control group. With regard the electrotherapy it seems to affect the bone healing mildly / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
18 |
Estimulação do nervo tibial posterior no tratamento da bexiga hiperativa / Transcutaneous posterior tibial nerve stimulation for the treatment of overactive bladder syndromeMarques, Andrea de Andrade 05 July 2008 (has links)
Orientador: Viviane Herrmann Rodrigues / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T00:13:29Z (GMT). No. of bitstreams: 1
Marques_AndreadeAndrade_D.pdf: 1123882 bytes, checksum: 0d246b4e1e0c7351ce6062d29d3ff7ca (MD5)
Previous issue date: 2008 / Resumo: Introdução: Bexiga Hiperativa é uma síndrome de alta prevalência, caracterizada por urgência miccional, com ou sem incontinência de urgência, geralmente acompanhada por freqüência e noctúria, em pacientes sem infecções ou outras patologias. O tratamento conservador tem sido recomendado como primeira linha para o tratamento da Bexiga Hiperativa. Entre os diferentes recursos fisioterapêuticos disponíveis, a eletroestimulação vem sendo utilizada há cerca de 30 anos com bons resultados, principalmente através de eletrodos intracavitários. Objetivo: avaliar os efeitos da eletroestimulação transcutânea no nervo tibial
posterior para o tratamento da Bexiga Hiperativa. Metodologia: Foram selecionadas 43 pacientes e divididas em dois grupos: grupo I (estímulo) recebeu a eletroestimulação durante 30 minutos, duas vezes por semana, por quatro semanas, utilizando corrente transcutânea, bifásica (alternada) com largura de pulso de 200 microssegundos, a uma freqüência de estímulo de 10Hz, com variação
de intensidade e freqüência (VIF) através de um canal e dois eletrodos. A intensidade foi mantida imediatamente abaixo do limiar motor. O grupo II (controle) foi submetido ao mesmo protocolo, porém sem passagem de corrente elétrica. Foram realizadas oito sessões. As medidas de avaliação incluíram exame urodinâmico e diário miccional, realizados antes e após o tratamento. Resultados: Houve diferença estatística entre o grupo estímulo e o grupo controle ao final do tratamento com relação à freqüência urinária (p=0,0001) e noctúria (p=0,0186). Com relação à urgência miccional, a diferença encontrada entre os grupos após o tratamento foi de p=0,05, apresentando melhora de 3,5 (DP +/- 3,9) para 1,5 (DP +/- 1,5) episódios ao dia. Houve melhora significativa nos episódios de Incontinência Urinária de Esforço (IUE) no grupo estímulo, quando comparadas ao grupo controle (p=0,0273). Não houve alteração significativa nos episódios de incontinência por urgência. A capacidade cistométrica máxima apresentou aumento significativo no grupo estímulo, variando em média de 322,9ml para 381,0ml (p=0,0328). Não foram observadas alterações significativas com relação ao primeiro desejo miccional. Em quatro casos do grupo estímulo e cinco casos do grupo controle houve desaparecimento das contrações não inibidas do detrusor. Nas pacientes em que as contrações não inibidas do detrusor se mantiveram (n=14), não foram observadas alterações significativas com relação à intensidade da contração ou volume infundido, quando comparados grupo controle e grupo estímulo. Conclusões: A eletroestimulação transcutânea do nervo tibial posterior demonstrou trazer benefícios às pacientes com Bexiga Hiperativa, trazendo melhora para alguns dos parâmetros objetivos e subjetivos da síndrome / Abstract: Introduction: Overactive Bladder (OAB) is a prevalent syndrome characterized by miccional urgency, with or without urge-incontinence, usually with frequency and noctúria, in patients without infection or other pathologies. Conservative management has been recomended as first-line treatment for OAB. Among the different physiotherapeutic resources available, electrical stimulation has been used for about 30 years with good results, mainly with intra-cavitary probes. Objective: to evaluate the effects of transcutaneous electrical nerve stimulation of the posterior tibial nerve in the treatment of the OAB. Methodology: A total of 43
women were selected and divided into two different groups: Group I (Stimulation) received electrical stimulation during 30 minutes, twice a week, during 4 weeks, using a TENS current, biphasic (alternating) with a pulse duration of 200 microseconds, stimulation frequency of 10Hz, with VIF (variation of intensity and frequency) through one channel and two electrodes. The intensity level was kept immediately under the motor threshold. Group II (Control) was submitted to the same protocol, but without electrical stimulation. Eight sections were done. Outcome measures included urodynamics exam and voiding diary before and after de treatment.
Results: There was statistical difference between Control and Stimulation group at the end of the treatment regarding to daytime urinary frequency (p=0.0001), and noctúria (p=0.0186). Regarding to urgency symptom, the difference found between the groups before and after treatment was p=0.05, improving from 3.5 (SD +/- 3.9) to 1.5 (SD +/- 1.5) episodes per day. There was improvement of stress urinary incontinence episodes in the Stimulation Group when compared to Control Group (p=0.0273). We didn¿t find statistical difference of urgeincontinence symptoms between the groups, before and after the treatment. The maximal cystometric capacity increased statistically at Stimulation Group increasing from 322.9ml to 381.0ml in media (p=0.0328). We didn¿t find difference between Stimulation and Control Group regarding first desire to void. In 4 cases from Stimulation Group and 5 cases from the Control Group, involuntary detrusor contraction (IDC) disappeared. Patients who maintained IDC (n=14), we didn¿t
find statistical difference regarding the intensity of the contraction or bladder volume at first contraction when compared Control and Stimulation Group. Conclusion: Transcutaneous posterior tibial nerve stimulation proved to be beneficial to patients with OAB, improving objective and subjective parameters / Doutorado / Ciencias Biomedicas / Doutor em Tocoginecologia
|
19 |
Efeitos da eletroestimulação neuromuscular no musculo tibial anterior de pacientes hemipareticos espasticosNunes, Ligia Christina Borsato Guimarães 15 July 2004 (has links)
Orientador: Antonio Augusto Fasolo Quevedo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T23:45:03Z (GMT). No. of bitstreams: 1
Nunes_LigiaChristinaBorsatoGuimaraes_M.pdf: 1112094 bytes, checksum: e491810518ee66305badb8d9c43312c2 (MD5)
Previous issue date: 2004 / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
|
20 |
Reabilitação em cães com atrofia muscular induzida /Souza, Soraia Figueiredo de. January 2010 (has links)
Resumo: Avaliou-se a resposta de diferentes protocolos fisioterapêuticos em cães após a indução de atrofia muscular por meio da imobilização do joelho por 30 dias. Os grupos foram denominados grupo C ou controle, grupo M (massagem e movimentação passiva), grupo E (massagem, movimentação passiva e eletroterapia), grupo H (massagem, movimentação passiva e hidroterapia em esteira aquática) e grupo EH (massagem, movimentação passiva, eletroterapia e hidroterapia em esteira aquática). Foram mensurados, os graus de claudicação, amplitude articular, circunferência da coxa, variação sérica das enzimas creatina-quinase e lactato-desidrogenase, bem como a morfometria muscular das fibras de contração rápida e contração lenta do músculo vasto lateral marcadas pela técnica de imunoistoquímica. Os cães do grupo H apresentaram retorno mais precoce à função do membro pélvico direito, mostrando que a hidroterapia pode ser beneficamente empregada para a recuperação em cães claudicantes. A fisioterapia reduziu a contratura articular. Verificou-se maior recuperação da área transversal das fibras musculares de contração lenta e rápida nos cães submetidos à eletroterapia aos 60 dias de pós-operatório. De acordo com os resultados encontrados, foi possível concluir que as modalidades terapêuticas de massagem, movimentação passiva da articulação, estimulação elétrica neuromuscular e hidroterapia por caminhada em esteira aquática aceleram a recuperação clínica em cães com atrofia muscular induzida / Abstract: The response to different physiotherapeutic protocols was evaluated in dogs with muscle atrophy induced by a 30-day-long immobilization of the stifle joint. The animals were divided in groups namely: C (control), M (massage and passive range of motion), E (massage, passive range of motion and neuromuscular electrical stimulation), H (massage, passive range of motion and hydrotherapy in underwater treadmill), and EH group (massage, passive range of motion, neuromuscular electrical stimulation and hydrotherapy in underwater treadmill). The degree of lameness, range motion, thigh circumference, range of serum creatine kinase (CK) and lactate dehydrogenase (LDH) were then evaluated, as well as the morphometry of fast- and slow-twitch muscle fibers of the vastus lateralis by immunohistochemistry. Group H dogs regained function of the right hind limb faster than the other groups. This result shows that hydrotherapy helped in the recovery process of lame dogs. Physiotherapy reduced the joint contracture. There was a higher recovery rate of cross-sectional area of slow-twitch and fast-twitch muscle fibers and thigh circumference in dogs submitted to neuromuscular electrical stimulation at 60 days post-surgery. According to these results, it was possible to conclude that therapeutics modalities such as massage, passive range of motion of the joint, neuromuscular electrical stimulation and hydrotherapy by walking on underwater treadmill accelerate clinical recovery in dogs with induced muscle atrophy / Orientador: João Guilherme Padilha Filho / Coorientador: Vera Maria Villamil Martins / Banca: André Luís Selmi / Banca: Marcelo Meller Alievi / Banca: Paola Castro Moraes / Banca: Renée Laufer Amorim / Doutor
|