• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 187
  • 187
  • 187
  • 187
  • 146
  • 143
  • 141
  • 34
  • 32
  • 27
  • 22
  • 17
  • 16
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Efeitos do uso de aditivo no leite humano cru da própria mãe em recém-nascidos pré-termo de muito baixo peso / Effects of the use of additive in the raw human milk of mothers of very low birth weight preterm newborns

Evelyn Conti Martins 01 December 2008 (has links)
A nutrição do recém-nascido pré-termo de muito baixo peso representa um desafio para a equipe multiprofissional devido a condições especiais, como o metabolismo acelerado, diminuição das reservas orgânicas, maior risco de complicações associadas à imaturidade do sistema digestivo e a capacidade reduzida de adaptação frente a situações de sobrecarga hidro-eletrolítica. A preocupação com a nutrição do pré-termo justifica-se pela necessidade de promover velocidade de crescimento físico e desenvolvimento semelhantes à da vida intra-uterina. Objetivos: a) Geral; comparar o ganho ponderoestatural e a freqüência de complicações clínicas em recém-nascidos prétermo com peso inferior a 1500g, alimentados exclusivamente com leite humano cru da própria mãe, com e sem a suplementação de aditivo, até atingirem o peso de 1800g; b)Específicos: descrever e comparar o ganho pondero-estatural e a freqüência de complicações clínicas em recém-nascidos pré-termo com peso inferior a 1500g, alimentados exclusivamente com leite humano cru da própria mãe, com e sem a suplementação de aditivo, até atingirem o peso de 1800g. Métodos: Ensaio clínico prospectivo randomizado duplo-cego em 40 recém-nascidos pré-termo com peso de nascimento inferior a 1500g internados em unidade de terapia intensiva neonatal no período de agosto de 2005 a abril de 2007. Para detectar a diferença de 3,0g/Kg/dia no ganho de peso, com desvio padrão de 4,0g/Kg/dia com nível de significância de 5% e poder de teste de 80%, foi calculada uma amostra com 20 neonatos em cada grupo (controle e intervenção). Na análise estatística foram utilizados o teste exato de Fisher, t de Student, Kolmogorov-Smirnov e teste não paramétrico de Mann Whitney. Resultados: O ganho ponderal nos recém-nascidos pré-termo de muito baixo peso que receberam leite humano cru da própria mãe com aditivo foi de 24,4g/dia e de 21,2g/dia no grupo que recebeu leite humano (p=0,075). Com relação ao comprimento, houve aumento de 1,09 cm/semana no grupo que recebeu leite humano cru da própria mãe com aditivo e 0,87cm/semana no grupo que recebeu leite humano puro (p=0,003). Quanto às complicações clínicas, não houve diferença significante com relação à intolerância digestiva, distensão abdominal, hipernatremia e episódios de infecção. Conclusões: A suplementação de aditivo no leite humano cru da própria mãe, na concentração de 5%, após a oferta hídrica da dieta atingir 100ml/Kg/dia e até o recém-nascido apresentar peso de 1800g, proporcionou ganho ponderal médio diário superior ao obtido no grupo controle, embora sem diferença significante. Houve aumento significativo do comprimento em relação ao grupo controle. Não foram observadas complicações clínicas relacionadas ao uso de aditivo no leite humano cru da própria mãe do recém-nascido pré-termo. / The nutrition of very low birth weight preterm newborns represents a challenge for a multiprofessional team due to special conditions, such as accelerated metabolism, reduction of organic reserves, higher risk of complications associated to the immature digestive system, and reduced capacity of adaptation in face of hydroelectrolytic overload situations. The concern with the preterm infant nutrition is justified by the need of promoting physical growth velocity and development similar to those in the intrauterine life. Objectives: a) General: to compare the ponderal-stature gain and the frequency of clinical complications in preterm newborns weighting less than 1500g, exclusively fed with their own mothers raw human milk with or without additive until reaching 1800g; b) Specific: to describe and compare the ponderal-stature gain and the frequency of clinical complications in preterm newborns weighting less than 1500g, exclusively fed with their own mothers raw human milk with or without additive until reaching 1800g. Methods: Prospective double-blind randomized controlled trial in 40 preterm newborns with birth weight lower than 1500g hospitalized in neonatal intensive care unit from August 2005 to April 2007. In order to detect the difference of 3.0g/Kg/day in the gain of weight, with standard deviation of 4.0g/Kg/day, significance level of 5% and power of test of 80%, a sample with 20 newborns in each group (control and intervention) was calculated. In the statistical analysis, Fisher exact test, t of Student, Kolmogorov-Smirnov test and Mann Whitney non-parametric test were utilized. Results: The ponderal gain in very low birth weight preterm newborns who have received raw human milk of their own mothers with additive was 24.4g/day and 21.2g/day in the group receiving human milk (p=0.075). In regard to the stature, there was an increase of 1.09 cm/week in the group receiving human milk of their own mothers with additive and 0.87cm/week in the group receiving pure human milk (p=0.003). As for clinical complications, there was no significant difference in regard to digestive intolerance, abdominal distension, hypernatremia and episodes of infection. Conclusions: The supplementation of additive in the own mother human milk, in the concentration of 5%, after the diet hydric offer supply reaches 100 ml/Kg/day and until the newborn weights 1800g, has allowed a daily average ponderal gain higher than that obtained in the control group, although with no significant difference. There was a significant increase of stature in regard to the control group. No clinical complications regarding the use of additive in the raw human milk of preterm newborns own mothers were observed.
92

Efeitos da suplementação de creatina combinada ou não ao treinamento físico em mulheres idosas: estudo clínico, randomizado, duplo-cego, controlado por placebo / Effects of creatine supplementation combined or not with exercise training in older women: a clinical, randomized, double-blind , placebo-controlled trial

Andre Regis Macedo 11 December 2014 (has links)
INTRODUÇÃO: O envelhecimento cada vez maior da população mundial é responsável pelo aumento na prevalência de sarcopenia, osteoporose e incapacidade física em indivíduos idosos mais vulneráveis. OBJETIVOS: Avaliar a eficácia da suplementação de creatina (CR), associada ou não ao treinamento de resistência ou força (RT) em mulheres idosas. MÉTODOS: 60 mulheres voluntárias acima de 60 anos de idade, sedentárias, participaram do estudo clínico randomizado, duplo-cego, controlado por placebo, durante 24 semanas, divididas em quatro grupos : placebo (PL), com suplementação de creatina (CR), placebo com treinamento de resistência (PL + RT) e suplementação de creatina com treinamento de resistência (CR + RT). As voluntárias foram avaliadas antes e depois de 24 semanas de intervenção. A força muscular foi avaliada por testes de uma repetição máxima (1RM). Outras variáveis foram incluídas como massa magra apendicular, massa óssea, marcadores de metabolismo ósseo e testes de capacidade física funcional. RESULTADOS: As alterações no teste de 1RM leg press foram significantemente maiores no grupo CR + RT (+ 19.9%) do que os grupos PL (+ 2.4%) e CR (+ 3.7%), mas não no grupo PL + RT (+ 15%) (p = 0.002, p = 0.002, e p = 0.357, respectivamente). O grupo CR + RT também demonstrou ganhos superiores no teste de 1RM supino (+ 10%) quando comparado com o grupo PL (- 3.1%, p = 0.03). Os grupos PL, CR, e PL + RT tiveram mudanças comparáveis no 1RM supino. O grupo CR + RT (+ 1.31%) apresentou melhora significativa na massa magra apendicular em relação aos grupos PL (- 1.2%), CR (+ 0.3%), e PL + RT (- 0.2%) (p < 0.05). Os grupos CR e PL + RT obtiveram ganhos comparáveis na massa magra apendicular (p = 0.62), porém superiores aos observados no grupo PL. Massa gorda, massa óssea e marcadores séricos de metabolismo ósseo não obtiveram diferenças significativas entre os grupos (p > 0.05). CONCLUSÕES: Suplementação de creatina a longo prazo combinado com treinamento de resistência pode melhorar massa magra / INTRODUCTION: The increasing aging of the world population is responsible for the increase in the prevalence of sarcopenia, osteoporosis and physical disability in vulnerable elderly. OBJECTIVES: The aim of this study was to examine the efficacy of creatine supplementation, associated or not with resistance training, in vulnerable older women. METHODS: Sixty subjects were assigned to compose a 24-week, double-blind, randomized, placebo controlled trial, and were divided into 4 groups : placebo (PL), creatine supplementation (CR), placebo with resistance training (PL + RT), and creatine supplementation with resistance training (CR + RT). The subjects were assessed at baseline (Pre) and after 24 weeks (Post). The primary outcome was muscle strength, as assessed by one-maximum (1-RM) tests. Secondary outcomes included appendicular lean mass, bone mass, biochemical bone markers, and physical function tests. RESULTS: The changes in 1-RM leg press were significantly greater in the CR + RT group (+ 19.9%) than in PL (+ 2.4%) and the CR groups (+ 3.7%), but not than in the PL + RT group (+ 15%) (p = 0.002, p = 0.002, and p = 0.357, respectively). The CR + RT group also showed superior gains in 1-RM bench press (+ 10%) when compared with the PL group (- 3.1%, p = 0.03). The PL, CR and PL + RT had comparable changes in 1-RM bench press. The CR + RT group (+ 1,31%) showed greater appendicular lean mass accrual than the PL (- 1,2%), the CR (+ 0.3%), and the PL + RT groups (- 0.2%) (p <0.05). The CR and the PL + RT groups experienced comparable gains in appendicular lean mass (p = 0.62), but superior to those seen in the PL group. Fat mass, bone mass and serum bone markers did not significantly differ between the groups (p > 0.05). CONCLUSIONS: Long-term creatine supplementation combined with resistance training can improve appendicular lean mass and muscle function, but not bone mass, in older vulnerable women
93

Suplementação de creatina associada ao treinamento fisíco em mulheres com osteoartrite de joelho: estudo clínico aleatorizado, duplo-cego, controlado por placebo / Creatine supplementation associated with resistance training in women with knee osteoarthritis: randomized, double-blind, placebo-controlled clinical trial

Manoel Tavares Neves Júnior 18 May 2011 (has links)
INTRODUÇÃO: O fortalecimento do quadríceps em pacientes com osteoartrite (OA) de joelho está associado à redução da dor, independência para caminhar e melhora funcional, salientando o papel dos exercícios físicos no tratamento dessa doença. Portanto, procedimentos capazes de aumentar os efeitos do exercício sobre força e função muscular podem ser potencialmente terapêuticos nesses pacientes. OBJETIVOS: Demonstrar a eficácia da suplementação de creatina associada ao treinamento de força (TF) no tratamento da OA de joelho. MÉTODOS: Mulheres entre 50 e 65 anos de idade com OA de joelho foram suplementadas com CR (20 g/d por 7 dias e depois 5 g/d até o fim do estudo) ou placebo (PL) e submetidas a um programa de TF por 12 semanas. Antes e após esse período, foram realizadas avaliações de capacidade física funcional (desfecho primário), dor, qualidade de vida, força muscular, composição corporal e função renal. RESULTADOS: Houve significante melhora da capacidade física funcional aferida pelo teste de levantar e sentar em 30 segundos (desfecho primário) apenas no grupo CR (P = 0,006). Além disso, foi observado efeito de interação entre grupos (CR PRÉ: 15,7 ± 1,4, CR PÓS: 18,1 ± 1,8; PL PRÉ: 15,0 ± 1,8, PL PÓS: 15,2 ± 1,2; P = 0,004). O grupo CR também apresentou melhora nos domínios de capacidade física funcional (P = 0,005) e de rigidez (P = 0,024) do Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), no índice algofuncional de Lequesne (P = 0,01) e na massa magra de membros inferiores mensurada pela densitometria de dupla emissão com fonte de raios X (P = 0,04). Em ambos os grupos houve redução da dor, tanto pela escala visual numérica quanto pelo domínio de dor do WOMAC (P < 0,05). De forma similar, houve aumento da força muscular pelo teste de 1 repetição máxima (P = 0,005), sem diferença entre grupos (P = 0,81). Não houve alteração na depuração de 51Cr-EDTA (CR PRÉ: 86,16 ± 14,36, PÓS: 87,25 ± 17,60 mL/min/1,73 m2; PL PRÉ: 85,15 ± 8,54, PÓS: 87,18 ± 9.64 mL/min/1,73 m2; P = 0,81), bem como em qualquer outro parâmetro de função renal avaliado (dosagem sérica de creatinina e ureia, depuração estimada de creatinina, dosagem de creatinina, ureia, albumina e proteína na urina de 24 horas e cálculo da razão albumina/creatinina na urina de 24 horas). CONCLUSÃO: A suplementação de CR melhora capacidade física funcional, qualidade de vida e massa magra de membros inferiores em mulheres com OA de joelho submetidas ao treinamento de força sem afetar a função renal / INTRODUCTION: Strengthening of the quadriceps muscle in patients with knee osteoarthritis (OA) is related to walking self-efficacy, reduced pain, and improved function, stressing the role of strengthening exercises in the treatment of this disease. Therefore, procedures capable of enhancing the exercise effects on muscle strength and function may be potentially therapeutic for knee OA patients. OBJECTIVES: To demonstrate the efficacy of creatine (CR) supplementation associated with strengthening exercises in knee OA. METHODS: Women aged 50 to 65 years with knee OA were allocated to receive either CR (20 g/d for one week and 5 g/d thereafter) or placebo (PL) and were enrolled in a lower limb resistance training program. They were assessed at baseline (PRE) and after 12 weeks (POST). The primary outcome was the physical function as measured by the timed-stands test. Secondary outcomes included pain, quality of life, muscle strength, body composition and renal function. RESULTS: Physical function was significantly improved only in the CR group (P = 0.006). Additionally, a significant betweengroup difference was observed (CR PRE: 15.7 ± 1.4, POST: 18.1 ± 1.8; PL PRE: 15.0 ± 1.8, POST: 15.2 ± 1.2; P = 0.004). The CR group also presented improvements in the subscales of physical function (P = 0.005) and stiffness (P = 0.024) of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Additionally, only the CR group presented a significant improvement in quality of life assessed by the Lequesne Index (P = 0.01) and in lower limb lean mass measured by dual X-ray absorptiometry (P = 0.04). Both CR and PL groups demonstrated significant reductions in pain assessed by the visual numeric scale and by the WOMAC subscale of pain (P < 0.05). Similarly, a main effect for time revealed an increase in muscle strength by the leg press 1 repetition maximum (P = 0.005) with no significant differences between groups (P = 0.81). Renal function measured by 51Cr-EDTA clearance was not different between groups (CR PRE: 86.16 ± 14.36, POST: 87.25 ± 17.60 mL/min/1.73 m2; PL PRE: 85.15 ± 8.54, POST: 87.18 ± 9.64 mL/min/1.73 m2; P = 0.81). Other kidney function parameters (serum creatinine and urea, estimated creatinine clearance and 24h-urinary creatinine, urea, albumine, protein and albumin:creatinine ratio) were also unchanged. CONCLUSION: CR supplementation improves physical function, quality of life, and lower limb lean mass in postmenopausal women with knee OA undergoing strengthening exercises and this supplementation does not affect renal function
94

Adiponectina modifica a resposta à suplementação de ômega-3 em humanos com fatores de risco cardiovascular / Adiponectin modifies the response to omega-3 suplementation in persons with cardiovascular risk factors.

Milena Maria de Araújo Lima Barbosa 27 March 2015 (has links)
INTRODUÇÃO: Ácidos graxos ômega-3 (-3) apresentam características cardioprotetoras e seu baixo consumo tem sido associado ao aumento da resistência insulínica e à baixa concentração de adiponectina no sangue. OBJETIVO: Testar se a suplementação com -3 melhora o perfil cardiometabólico em humanos com fator de risco cardiovascular e se a concentração basal de adiponectina modifica a resposta a essa suplementação. MÉTODOS: Neste ensaio clínico, duplo-cego, placebo-controlado e paralelo, distribuímos aleatoriamente 80 indivíduos nos grupos -3 (suplementado com 3,0 g/dia de óleo de peixe, contendo 37 por cento de ácido eicosapentaenoico [EPA] e 23 por cento de ácido docosahexaenoico [DHA]) e placebo (3,0 g/dia de óleo de girassol, contendo 65 por cento de ácido linoleico), ambos suplementados durante dois meses. Avaliamos concentração sérica de adiponectina e leptina, perfil lipídico e de apolipoproteínas, LDL eletronegativa, marcadores inflamatórios (interleucinas 2, 4, 6, 8 e 10, MCP1, IFN- e TNF-) e metabolismo glicídico (glicose e insulina), adotando nível de significância de 5 por cento . RESULTADOS: No momento basal, os grupos -3 e placebo foram semelhantes quanto ao sexo, idade (média de 52,0 anos), raça, estado civil, trabalho, escolaridade e renda. Após intervenção, o grupo -3 aumentou a concentração sérica de adiponectina. No geral, as citocinas apresentaram redução após intervenção em ambos os grupos; IL-10 foi a única cuja concentração média aumentou, no grupo -3, mas, sem diferença significativa entre os grupos. Ao estratificar os indivíduos do grupo -3 segundo concentração basal de adiponectina, aqueles com menores concentrações tiveram maior redução de colesterol total, LDL, LDL/HDL, LDL/Apo B e LDL(-). Indivíduos que apresentaram maior variação da concentração de adiponectina reduziram a glicemia. CONCLUSÕES: A suplementação com -3 melhora o perfil cardiometabólico e aumenta a concentração sérica de adiponectina em indivíduos com fatores de risco cardiovascular. Indivíduos com baixa concentração basal de adiponectina são mais beneficiados pela ingestão desses ácidos graxos. / BACKGROUND: Omega-3 fatty acids (-3) have shown cardioprotective characteristics and their low consumption has been associated with increased insulin resistance and low blood concentration of adiponectin. OBJECTIVE: To analyze if -3 supplementation improves cardiometabolic profile in humans with cardiovascular risk factor and if adiponectin concentration at baseline level modifies the response to this supplementation. METHODS: In this double-blind, placebo-controlled, clinical trial, we randomized 80 subjects into two groups: -3 (supplemented with 3.0g/day of fish oil containing 37 per cent eicosapentaenoic acid [EPA] and 23 per cent docosahexaenoic acid [DHA]) and placebo (3.0g/day of sunflower oil containing 65 per cent linoleic acid). Both groups received supplementation for two months. At baseline period and after eight weeks of intervention, we evaluated serum adiponectin and leptin, lipid profile and apolipoproteins, electronegative LDL, inflammatory markers (interleukin 2, 4, 6, 8 and 10, MCP1, IFN- and TNF-) and glucose metabolism (glucose and insulin). The significance level was set at p <0.05. RESULTS: At baseline period, -3 and placebo groups were similar regarding sex, age (mean age of 52.0 years), race, marital status, occupation, education and income. After supplementation, -3 group presented an increased serum adiponectin. In general, for both -3 and placebo groups, the concentration of cytokines decreased after intervention IL-10 was the only cytokine that increased the concentration; however, -3 group showed similar variations when compared to the placebo group. After -3 group were stratified by adiponectin concentration at baseline, we observed that individuals with lower adiponectin concentration had a higher reduction of total cholesterol, LDL, LDL/HDL, LDL/Apo B and LDL (-). Individuals who had a higher variation of adiponectin concentration presented reduced blood glucose. CONCLUSIONS: -3 supplementation improves cardiometabolic profile and increases serum adiponectin in people with cardiovascular risk factors. Individuals with low basal concentration of adiponectin are more benefited by the intake of these fatty acids.
95

Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte III: avaliação da função mastigatória / Simplified versus conventional method for complete denture fabrication for application in public health. Part III: Assessment of masticatory function

Cunha, Tatiana Ramirez 13 December 2011 (has links)
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém é importante que a mastigação não sofra influências deletérias. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a performance e a habilidade mastigatórias. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais duplas. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=17), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=18), que recebeu próteses confeccionadas de forma convencional. Após 3 meses da instalação das próteses, a performance mastigatória foi avaliada por um método colorimétrico, utilizando duas biocápsulas como alimento teste, após 20 e 40 ciclos mastigatórios, e a habilidade mastigatória dos participantes foi avaliada por meio de questionário (Questionário HM) e escala visual analógica (EVA). Foi feita referência dos resultados a um grupo de participantes dentados, Grupo DN (n=17). Os três grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). A performance mastigatória foi similar nos grupos C e S e representou 31% daquela encontrada no grupo DN. A habilidade mastigatória foi semelhante para S e C independente do método de análise, sendo que algumas questões do questionário HM, analisadas isoladamente, tiveram maior ocorrência de respostas favoráveis para o primeiro. Conclui-se que métodos simplificados de confecção de próteses totais são capazes de reabilitar a mastigação de maneira comparável ao método convencional, tanto fisiologicamente como segundo as percepções do paciente. / Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones and mastication should not be further impaired. Therefore, this study aimed to compare a simplified method and a conventional protocol for complete denture fabrication, in terms of masticatory performance and ability. A sample was formed by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two groups: Group S (n=17), which received dentures fabricated by a simplified method, and Group C (n=18), which received conventionally fabricated dentures. After 3 months following insertion, masticatory performance was evaluated by means of a colorimetric assay based on chewing two capsules as test food during 20 and 40 cycles. Masticatory ability was assessed by means of a questionnaire (HM) with dichotomous answers and a single question answered by means of a visual analogue scale (VAS). A third group (DN, n=17) formed by dentate volunteers served as an external comparator. Results for the three groups were compared by means of statistical tests suitable for the distribution of data (&alpha;=5%). Groups C and S presented similar masticatory performance which corresponded to 31% of group DN. Results for masticatory ability showed similarity between S and C, regardless of the assessment method, though some isolate items of the HM questionnaire showed more favorable results for the first group. It can be concluded that simplified methods for complete denture fabrication are able to restore masticatory function to a level comparable to the conventional protocol, physiologically and according to patient perceptions.
96

Sobredentaduras mandibulares retidas por mini implantes: um ensaio clínico randomizado (parte I) / Mandibular overdentures retained by conventional or mini implants: a randomized clinical trial (parte I)

Ribeiro, Adriana Barbosa 13 January 2015 (has links)
A retenção de próteses totais removíveis por mini-implantes é uma modalidade de tratamento relativamente recente, com potencial de minimizar o trauma pós-operatório e reduzir custos associados. Este estudo buscou comparar a qualidade de vida relacionada à saúde bucal e satisfacão do paciente, bem como dor e desconforto pós-operatórios, decorrentes da instalação de mini-implantes (dois ou quatro) ou dois implantes de dimensões regulares para a retenção de sobredentaduras mandibulares. Cento e vinte participantes edentados (media etária 59,5±8,5 anos) foram alocados aleatoriamenteem três grupos conforme o tratamento recebido: (GI) quatro mini-implantes, (GII) dois mini-implantes, ou (GIII) dois implantes regulares. Sete dias após a instalação dos implantes, os participantes responderam questões (Escala visualanalógica - EVA de 100 mm) referentes à dor, edema e desconforto durante mastigação, fala e higiene, considerando as experiências vividas durante os períodos avaliados. Antes das intervenções e passados 3 e 6 meses da instalação das sobredentaduras, a qyalidade de vida relacionada à saúde bucal foi avaliada por meio do questionário OHIP-EDENT, e a satisfação analisada por perguntas específicas respondidas emu ma EVA de 100 mm. Os grupos foram comparados por meio de ANOVA para dois fatores ou Equações de Estimação Generalizadas (EEG) (&alpha;=0,05). Todos os participantes (GI: 38; GII: 42; GIII: 40) foram analisados após sete dias da instalação dos implantes instalação para dor e desconforto pós-operatório, e 112 responderam às questões sobre qualidade de vida relacionada à saúde bucal e satisfação de paciente. Ao 6º dia, GI sentiu dor significantemente maior que GII e GIII. GI também notou maior dificuldade para a prática de higiene oral que GIII durante o 1º dia. Não houve diferença significante entre os grupos para outras questões e períodos. Os achados para o OHIP-EDENT indicam que tanto os grupos tratados com dois ou quatro mini-implantes levaram a uma maior QVSB, comparados aos implantes convencionais. Aos três e seis meses, encontramos que os três grupos tratados com quatro mini-implantes estavam mais satisfeitos que os que receberam dois implantes convencionais e dois mini-implantes resultaram em valores intermediários. Conclui-se que o uso de quatro mini-implantes induz maior dor pós-operatória ao sexto dia que a inserção de dois mini-implante ou implantes convencionais, bem como higiene oral mais difícil ao primeiro dia. Além disso, o tratamento com sobredentaduras retidas por mini-implantes é comparável ao padrão de tratamento para o edentulismo, de acordo com as perspectivas do paciente. O tratamento por dois ou quatro mini-implantes alcança resultados similares ou mesmo discretamente superiores em termos de qualidade de vida relacionada à saúde bucal ou satisfação do paciente, comparado aos implantes convencionais / The retention of removable dentures by mini-implants is a relatively recent treatment modality, and may lead to minimal postoperative trauma and reduced costs. This study aimed to compare oral health-related quality of life and patient satisfaction, as well as postoperative pain and discomfort, following the insertion of mini-implants (two or four) or two standard-size implants for the retention of mandibular overdentures. One hundred and twenty edentulous participants (mean age 59.5±8.5 years) were randomly allocated into three groups according to received treatment: (GI) four mini-implants, (GII) two mini-implants, or (GIII) two standard implants. Seven days after implant insertion, patients answered questions (100-mm VAS Visual Analog Scale) relating to pain, swelling, and discomfort with chewing, speech and hygiene, considering their experiences during the 1st and 6th day. Before the interventions and after 3 and 6 months following insertion, OHRQoL was evaluated by means of the OHIP-EDENT questionnaire and patient satisfaction was analyzed by a specific questionnaire answered on a 100-mm VAS. Groups were compared by two-way ANOVA or Generalized Estimating Equations (GEE) (&alpha;=0.05). All participants (GI: 38; GII: 42; GIII: 40) were analyzed after seven days of postoperative pain and discomfort, and 112 answered questions regarding oral health-related quality of life and patient satisfaction. At the 6th day, GI felt significantly higher pain than GII and GIII. GI also reported more difficulty in performing oral hygiene practices than GIII during the 1st day. There was no significant difference between groups for the other questions and periods. The findings from OHIP-EDENT indicate that both two and four mini-implants led to better OHRQoL, compared to two conventional implants. At three and six months, we found that the group treated with four mini-implants was more satisfied than the two conventional implants and two mini-implants was presented intermediate values. It can be concluded that the use of four mini-implants induces more intense postoperative pain at the 6th day than the insertion of two mini- or conventional fixtures, as well as more difficult oral hygiene on the 1st day. Furthermore, the treatment by mini-implant overdentures is comparable to the standard of care for edentulism, according to the patient perspective. Treatment by either two or four mini-implants achieve similar or even slightly better OHQoL and satisfaction compared to two conventional implants
97

Estudo clínico randomizado em chagásicos submetidos à terapia de ressincronização cardíaca (TRC - Chagásico) / Randomized clinical study in Chagas disease undergoing cardiac resynchronization therapy (CRT - Chagas` Disease)

Lourenço, Uelra Rita 12 May 2016 (has links)
INTRODUÇÃO: A terapia de ressincronização cardíaca(TRC) tem se mostrado alternativa eficiente para pacientes com Insuficiência Cardíaca (IC) em uso terapia medicamentosa otimizada, com fração de ejeção reduzida e QRS largo. Apesar dos resultados positivos em pacientes de diversas etiologias, dados a despeito do efeito dessa terapia na cardiopatia chagásica são extremamente raros na literatura. OBJETIVOS: Avaliar a evolução clínica e funcional de pacientes chagásicos submetidos à terapia de ressincronização cardíaca, por meio de estudo clínico randomizado. CASUÍSTICA E MÉTODOS: Foram incluídos pacientes com cardiopatia chagásica, em Classe funcional II, III ou IV da NYHA, em uso de terapia medicamentosa otimizada, fração de ejeção <= 35% e duração do QRS largo. O presente estudo clínico é prospectivo, de intervenção, randomizado, cego, com crossover e comparou as respostas clínicas e funcionais após duas fases: período de 2 meses com a TRC ligada e período de 2 meses com a TRC desligada. As variáveis analisadas foram distância percorrida no teste de caminhada de 6 minutos, classe funcional (NYHA), pontuação no teste de qualidade de vida do questionário de Minnesota, pontuação no teste de capacidade funcional no questionário SF 36, pico de extração de oxigênio no teste cardiopulmonar e fração de ejeção do ventrículo esquerdo. RESULTADOS: Foram randomizados 34 pacientes sendo que seis não conseguiram completar as duas fases do estudo. A média da distância percorrida no Teste de Caminhada de 6 minutos foi 60 metros maior no grupo TRC ligada (500,3 versus 439,8 metros; p<0,01), o teste de Qualidade de Vida (Questionário de Minnesota) apresentou escores estatisticamente melhores nos pacientes com TRC ligada (diferença entre os dois grupos de 12,2 pontos, p<0,05). A Capacidade Funcional avaliada pelo questionário SF 36 apresentou resultado a favor da TRC ligada (p<0,01). De modo semelhante, a Classe Funcional (NYHA) média foi significativamente inferior neste grupo (p<0,05). As variáveis estudadas no Teste Cardiopulmonar e os parâmetros Ecocardiográficos não atingiram diferenças com significância estatística entre os dois grupos. CONCLUSÃO: Os resultados encontrados neste estudo suportam o valor terapêutico da TRC em indivíduos com insuficiência cardíaca de etiologia chagásica com QRS largo. A estimulação biventricular promoveu melhora significativa dos sintomas, qualidade de vida, capacidade funcional e da distância percorrida no teste de caminhada. Estudos subsequentes são necessários para avaliação dos efeitos clínicos a longo prazo e o impacto em mortalidade desta modalidade terapêutica nos pacientes com cardiopatia chagásica. / BACKGROUND: Cardiac Resynchronization Therapy (CRT) has been shown one effective alternative for patients under optimal medical therapy, reduced ejection fraction (EF) and wide QRS. Despite the positive results in patients of several etiologies, data from this therapy in Chagas heart disease are extremely rare in the literature. OBJECTIVES: To evaluate the clinical and functional results of Chagas patients undergoing CRT through a randomized clinical trial. METHODS: There were included patients with Chagas cardiomyopathy, functional class II, III or IV of NYHA, under optimal drug therapy, EF <= 35% and wide QRS. This prospective, randomized, blinded, crossover study compared the clinical and functional responses after two phases: a two-month period of CRT-on and a two-month period of CRT-off. The outcomes analyzed were: walked distance in 6 minutes, functional class (NYHA), quality of life by the Minnesota Living with Heart Failure Questionnaire score, functional capacity by the questionnaire SF 36 score, Oxygen Extraction Peak in Cardiopulmonary Test and EF of the Left Ventricle. RESULTS: Thirty four patients were randomized but six patients failed to complete both study periods. The average distance walked in 6 minutes was 60 meters higher in CRT-on group (500.3 vs. 439.8 meters, p <0.01), the Quality of Life (Minnesota Questionnaire) showed scores significantly better in patients with CRT- on (difference of scores between the two groups: 12.2, p <0.05). The functional capacity assessed by the SF-36 questionnaire showed better results in favor of CRT-on group (p <0.01). Similarly, the functional class (NYHA) was significantly lower in this group (p <0.05). The variables studied in Cardiopulmonary Testing and Echocardiographic parameters did not reach statistical significance between the two groups. CONCLUSION: The results of this study support the therapeutic value of CRT in patients with heart failure due to Chagas disease with wide QRS. The biventricular pacing significantly improved symptoms, quality of life, functional capacity and the distance walked in 6 minutes. Further studies are needed to evaluate the clinical long-term effects and the impact on mortality of this therapeutic modality in patients with Chagas heart disease.
98

Tratamento da hipersensibilidade dentinária com verniz de fluoreto de sódio a 5% terapia com laser de baixa intensidade e aplicação associada : estudo clínico, controlado, randomizado, duplo cego, boca dividida. /

Paixão, Aline Kataki. January 2018 (has links)
Orientador: Andrea Carvalho De Marco / Coorientador: Dimas Renó de Lima / Banca: Symone Cristina Teixeira / Banca: Cibelle Barbosa Lopes / Resumo: A hipersensibilidade dentinária é uma das complicações mais comuns entre os pacientes após o tratamento periodontal. Recentemente a terapia com o uso de laser de baixa intensidade foi introduzida como uma nova modalidade de tratamento e tem proporcionado resultados benéficos. Foi realizado um estudo clínico controlado, randômico, duplo-cego, de boca dividida com o objetivo de comparar a efetividade do uso do verniz tópico Fluoreto de sódio 5%, do Laser GaAlAs 780 nm e da combinação do Fluoreto de sódio 5% e o Laser GaAlAs 780 nm para o tratamento de hipersensibilidade dentinária. Os Grupos foram divididos em Grupo Controle (C), Grupo Fluoreto de sódio 5% (F), Grupo Laser GaAlAs 780 nm (LLLT), e o Grupo Fluoreto de sódio 5% + Laser GaAlAs 780 nm (F+LLLT). A aplicação do verniz foi realizada com pinceis do tipo "microbrush", e para cada elemento dental cinco pontos receberam a LLLT, com dose de 52,5 J/cm2 (70mW e 30 segundos) ou 2,1 J por ponto; 6 segundos por ponto. A hipersensibilidade primária foi registrada pela escala analógica visual (VAS: 0-10) para quantificar a dor subjetiva após estímulo com "spray de gelo" no baseline, e após o tratamento nos intervalos de 24 horas e 30 dias. Todos os dados foram analisados estatisticamente pela análise de variância ANOVA. Para cada um dos três tempos de avaliação foi efetuada uma comparação entre os 4 grupos (por meio da ANOVA oneway) com complementação pelos testes de Tukey e Bartlett a fim de verificar as diferenças estatísticas e... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dentin hypersensitivity is one of the most common complications among patients after periodontal treatment. Recently the low level laser therapy has been introduced as a new treatment modality and has provided beneficial results. A split-mout, double-blind, randomized, controlled clinical trial was conducted with the aim of compare the effectiveness of the topical varnish 5% Sodium Fluoride, Laser GaAlAs 780 nm and the combination of 5% Sodium Fluoride and the Laser GaAlAs 780 nm for the treatment of dentin hipersensitivity. The groups were divided in Control Group (C), Sodium Fluoride at 5% Group (F), Laser Group GaAlAs 780 nm (LLLT), and Sodium Fluoride at 5% Group + GaAlAs Laser 780 nm (F + LLLT). The application of the varnish was realized with "microbrush", and for each dental element, five points was received LLLT. The dose was 52.5 J / cm2 (70mW and 30 seconds) or 2.1 J per point, 6 seconds per point. Primary hypersensitivity was be recorded by visual analogue scale (VAS: 0-10) to quantify subjective pain after the stimulus with "ice spray" at baseline, and after treatment at 24-hour and 30-day intervals. All data was analyzed statistically by analysis of variance ANOVA. For each of the three evaluation times a comparison was made between the 4 groups (through the oneway ANOVA) with complementation by the Tukey's and Bartlett's tests in order to verify the statistical differences between groups. The level of significance will be 5%. After statistical analysis the resul... (Complete abstract click electronic access below) / Mestre
99

Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte II: qualidade de vida associada à saúde bucal, satisfação do paciente, qualidade das próteses / Simplified versus conventional method for complete denture fabrication for application in public health. Part II: oral health related quality of life, patient satisfaction and denture quality

Romulo Rocha Regis 19 July 2012 (has links)
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém com menor gasto de tempo e recursos, sem representar prejuízos aos usuários. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a qualidade de vida associada à saúde bucal (QVSB), a satisfação dos pacientes e qualidade das próteses. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais bimaxilares. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=19), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=20), que recebeu próteses confeccionadas de forma convencional. Antes dos tratamentos e após 3 e 6 meses da instalação das próteses, a QVSB foi avaliada por meio do questionário OHIPEDENT e a satisfação dos usuários por meio de um questionário específico e escala visual analógica. A qualidade das próteses foi avaliada após 3 meses por um especialista. Os dois grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). A QVSB e qualidade das próteses foram similares nos grupos C e S. Não houve diferença entre os grupos quanto à satisfação geral avaliada pelos dois questionários. Diferenças em relação à satisfação dos usuários com aspectos específicos das próteses só ocorreram na avaliação dos 3 meses, não persistindo na segunda avaliação. Conclui-se que métodos simplificados são capazes de produzir próteses totais de qualidade comparável às geradas por métodos convencionais, influenciando a QVSB e a satisfação de seus usuários de forma similar. / Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones albeit the lesser use of time and resources, without disadvantage to the denture wearer. Thus, the purpose of this study was to compare a simplified method for complete denture fabrication to a conventional protocol in a randomized controlled trial in terms of oral health quality of life (OHRQoL), patient satisfaction and denture quality. A sample was created by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two study groups. Group S (n=19), which received dentures fabricated by a simplified method, and Group C (n=20), which received conventionally fabricated dentures. Before the interventions and after 3 and 6 months following insertion, OHRQoL was evaluated by means of OHIP-EDENT questionnaire and patient satisfaction was analyzed by a visual analogue scale and a specific questionnaire. Denture quality was assessed 3 months after delivery by a prosthodontist. Groups were compared by means of statistical tests suitable for the distribution of data (&alpha;=5%). Groups presented no difference for OHRQoL, denture quality and patient general satisfaction. Differences regarding to patient satisfaction with specific aspects of the dentures were found after 3 months, but were insignificant at 6 months. It was concluded that the simplified method is able to produce complete dentures of a quality comparable to those produced by the conventional protocol, influencing the OHQoL and satisfaction of their wearers similarly
100

Educação a distância na qualificação do cuidado da asma em atenção primária : ensaio clínico randomizado em cluster - RESPIRANET

Roman, Rudi January 2017 (has links)
Asma é uma doença crônica, de alta prevalência, importante causa de morbidade, responsável por gastos diretos e indiretos significativos. Apesar do cuidado padrão para esta doença estar bem consolidado em diretrizes clínicas baseadas em evidências, frequentemente seus portadores não recebem os cuidados indicados. A qualidade da assistência dispensada pelos profissionais da atenção primária é tanto problema quanto solução. Modelos de cuidados adaptados a doenças crônicas e iniciativas de educação em saúde correspondem a estratégias utilizadas para incremento de qualidade assistencial. As novas tecnologias de informação e comunicação têm encurtado progressivamente as distâncias entre as pessoas. Em saúde, têm sido utilizadas como ferramentas valiosas na disseminação de conhecimentos. Apesar da ampla disponibilidade e utilização, os recursos educativos mediados por tecnologias de informação e comunicação – teleducação – ainda carecem de evidências de maior rigor científico. Objetivo: avaliar a efetividade clínica de uma intervenção multifacetada educativa a distância sobre asma para profissionais da atenção primária à saúde. Método: ensaio clínico randomizado em cluster com 71 equipes de saúde do interior do Rio Grande do Sul. Foram indicados pela totalidade das equipes 443 pessoas com diagnóstico de asma elegíveis para acompanhamento no estudo. As equipes do grupo intervenção (n = 34) participaram de um programa de 3 sessões interativas online e receberam materiais educativos. As equipes do grupo controle (n = 37) não sofreram intervenção. Sobrecarga de sintomas nos últimos 14 dias, controle da asma no último mês, necessidade de consulta não programada nos últimos 6 meses e uso de corticosteroide inalatório preventivo nos últimos 6 meses foram avaliados nas pessoas indicadas pelas equipes na linha de base e 6 meses após a intervenção. Resultados: a assiduidade geral das equipes de saúde às sessões interativas online foi de 50%. Ambos grupos apresentaram melhora dos desfechos clínicos e menor uso de corticosteroide inalatório no seguimento. Exposição a intervenção educacional esteve associada a razões de chances com melhores desfechos clínicos, entretanto com significância estatística limítrofe. Não foram observadas diferenças no uso de corticosteroides inalatórios preventivos entre os grupos. Conclusão: a intervenção em educação a distância demonstrou potencial apesar da baixa assiduidade das equipes sob intervenção. O modelo proposto é factível e reprodutível. Integração com o sistema de registro clínico pode potencializar os resultados. A implementação de estratégias de aperfeiçoamento profissional em caráter institucional deve ser orientada pelas melhores evidências. / Asthma is a high prevalence chronic disease and an important cause of morbidity, responsible for significant direct and indirect health expenses. Although the standard care for this condition is well established in evidence-based clinical guidelines, often patients do not receive the indicated treatment. The quality of care delivered by primary care professionals is both a problem and a solution. Models of care adapted to chronic diseases and health education initiatives are strategies used to increase care quality. New information and communication technologies have progressively shortened distances between people. In healthcare, they have been used as a valuable tool for knowledge dissemination. Despite widespread availability and use, educational resources mediated by information and communication technologies still lack evidence of greater scientific rigor. Objective: to evaluate the clinical effectiveness of a multifaceted distance educational intervention on asthma for primary health care professionals. Methods: cluster randomized clinical trial with 71 health teams from country towns of Rio Grande do Sul. The teams identified a total of 443 persons diagnosed with asthma who were eligible for follow-up in the study The teams in the intervention group (n = 34) participated in a program of 3 interactive online sessions and received educational materials. There was no intervention in the control group teams (n = 37). Symptoms overload in the last 14 days, control of asthma in the last month, need for unplanned consultation in the last 6 months and use of preventive inhaled corticosteroids in the last 6 months were evaluated in the individuals indicated by the teams at the baseline and 6 months after the intervention. Results: The general assiduity of health teams to online interactive sessions was 50%. Both groups showed improved clinical outcomes and used less inhaled corticosteroids at follow-up. Exposure to educational intervention was associated with better clinical outcomes odds ratios, however, with borderline statistical significance. No differences were observed in the use of preventive inhaled corticosteroids between groups. Conclusion: The distance education intervention showed potential despite the low attendance of the intervention teams. The proposed model is feasible and reproducible. Integration with the clinical record system can boost results. The implementation of professional development strategies should be guided by the best evidence in an institutional setting. / Telemedicina

Page generated in 0.0948 seconds