• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 349
  • 349
  • 218
  • 216
  • 46
  • 35
  • 34
  • 29
  • 26
  • 26
  • 25
  • 24
  • 23
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Adrenoleucodistrofia cerebral ligada ao x

Ono, Sergio Eiji 28 May 2013 (has links)
Resumo: OBJETIVO: o padrão-ouro em exames de imagem para avaliar a adrenoleucodistrofia ligada ao X é o escore de Loes, baseado na localização, alterações de sinais e grau de atrofia. Os objetivos deste estudo foram avaliar como os parâmetros do tensor de difusão correlacionam com o escore de Loes e avaliar se poderiam indicar alterações estruturais precoces. PACIENTES E MÉTODOS: as medidas do tensor de difusão foram obtidas em 9 locais pré-estabelecidos da substância branca, bilateralmente, em 30 exames de 14 pacientes com adrenoleucodistrofia ligada ao X. Os escores individuais de fração de anisotropia e difusibilidades média, radial e axial foram obtidos como uma simples soma das 18 medidas e estatisticamente correlacionadas com o escore de Loes correspondente. Um grupo controle de 28 pacientes masculinos foi avaliado para estabelecer escores do tensor de difusão pareados por idade. Análises estatísticas intra e interobservador foram feitas. RESULTADOS: os escores do tensor de difusão apresentam forte correlação com o escore de Loes segundo o coeficiente de Pearson (r), com valores de -0,86; 0,89; 0,89 e 0,84 para escores de fração de anisotropia e difusibilidades média, radial e axial (p < 0,01). A análise estatística intra e interobservador dos escores dos tensores de difusão para pacientes com adrenoleucodistrofia e no grupo controle indicam um método robusto. A análise da mudança nas medidas do tensor de difusão no estágio inicial da doença indica que os valores de difusibilidades média e radial podem ajudar a predizer a progressão da doença. CONCLUSÃO: os escores de parâmetros do tensor de difusão poderiam ser usados como um adjunto ao escore de Loes, auxiliando no monitoramento da doença e alertando uma possível progressão do escore de Loes na faixa de interesse para decisões terapêuticas.
22

Recirculação sanguínea em hemodiálise : estudo comparativo em três métodos de acesso vascular

Oliveira, Rubens Marona de January 1984 (has links)
Analisaram-se alguns problemas associados ao uso do acesso vascular em hemodiálise, revisando-se os vários métodos de utilização do acesso vascular, suas indicações, vantagens e desvantagens. Destacou-se a importância da recirculação sanguínea, bem como suas causas e conseqüências. Efetuaram-se, no transcorrer do estudo, 85 determinações da porcentagem de reeirculação sanguínea, durante 30 sessões de hemodiálise, utilizando a dosagem da uréia sanguínea. Foram realizadas 29 determinações da porcentagem de recirculação com uso de duas agulhas, 28 com cânula única de dupla luz coaxial em fístula arteriovenosa e 28 determinações com cateter de luz única em veia cava superior. Verificou-se diferença significativa nas determinações, quando comparadas as médias das porcentagens de recirculação obtidas com acesso vascular por duas agulhas com as médias obtidas no acesso por cânula de dupla luz coaxial em fístula arteriovenosa. Também ocorreu diferença significativa entre as médias das porcentagens de recirculação, quando comparou-se o acesso vascular por duas agulhas em fístula arteriovenosa com o acesso cateter de luz única conectado a equipamento ciclador, em veia cava superior. Não se demonstrou diferença significativa entre as médias das porcentagens de recirculação obtidas com cânula de dupla luz coaxial em fístula arteriovenosa e cateter de luz única em veia cava superior. Observou-se que a porcentagem de recirculação não está significativamente relacionada com a distância entre as agulhas colocadas em fístula arteriovenosa, em diálises por duas agulhas. Por outro lado, não houve correlação significativa entre porcentagem de recirculação e número de reutilização dos dialisadores, em qualquer dos grupos analisados. No estudo do decaimento da uréia, constatou-se não haver diferença entre os decaimentos, quando comparadas as diálises efetuadas com cânula de dupla luz coaxial e aquelas realizadas com duas agulhas em fístula arteriovenosa. Houve diferença significativa nos decaimentos, quando comparadas diálises efetuadas com duas agulhas e cateter de luz única, bem como quando comparadas diálises com cânula de dupla luz coaxial e cateter de luz única.
23

Estudo comparativo do desempenho de diferentes eletrodos ventriculares no seguimento a médio prazo pós-implante de marcapasso

Sales, Marcela da Cunha January 2008 (has links)
INTRODUÇÃO: O número de implantes de marcapassos vem crescendo consideravelmente e também a utilização de eletrodos de fixação ativa eluídos com corticóides. No entanto, dados prospectivos do desempenho destes eletrodos a médio e longo prazo são, ainda, bastante restritos. OBJETIVOS: O objetivo principal deste estudo é determinar a estabilidade dos parâmetros elétricos ao longo do tempo (limiares de estimulação, medidas de sensibilidade e de impedância) para dois eletrodos ventriculares diferentes, ambos eluídos com corticóide, sendo um de fixação ativa e um de fixação passiva e compará-los entre si. Também queremos determinar o momento em que há estabilização destas medidas. PACIENTES E MÉTODOS: Pacientes com indicação de implante de marcapasso foram alocados em dois grupos: Grupo A – implante de eletrodo ventricular de fixação ativa (Setrox S-Biotronik) e Grupo P – implante de eletrodo ventricular de fixação passiva (Selox ST-Biotronik), ambos eluídos com corticóides. Foram realizadas medidas de parâmetros elétricos durante o implante, 48h, 15d, 30d, 60d, 90 e 180d: medidas de sensibilidade, impedância e de limiares de estimulação com diferentes larguras de pulso (0,2, 0,4 e 0,5ms). RESULTADOS: Foram incluídos, de forma não randomizada, 55 pacientes, com idade média de 72 ± 9 anos, sendo 31(56,36%) do sexo masculino. A principal indicação de implante foi Bloqueio Átrio-Ventricular de 3º grau (31 pacientes - 56,36%). Características clínicas basais foram iguais nos dois grupos. Análise das medidas de parâmetros elétricos: Sensibilidade ventricular (onda R): Não houve diferença entre as medidas feitas nos diferentes tempos em cada grupo (grupo A, P=0,314 e grupo P, P=0,327 entre os diversos tempos). Também não houve diferença entre as curvas dos dois grupos entre si (P=0,78 para as comparações entre as curvas). Medidas de impedância do eletrodo ventricular: Nos dois grupos (A e P) houve diminuição significativa das impedâncias em 48h e 15d (P<0,0001 e P=0,007 respectivamente). A partir de 15 dias, as curvas das impedâncias dos dois grupos estabilizaram, não havendo mais diferença significativa entre os valores médios. Na comparação entre os valores de impedância das duas curvas, o grupo P teve valores significativamente mais elevados em todos os momentos em que houve medição (P=0,01). Medidas dos limiares de estimulação ventricular: os grupos A e P tiveram achados semelhantes para as medidas com as diferentes larguras de pulso: em 48hs houve uma leve tendência de queda do limiar sem significância estatística, seguida de uma elevação importante (com significância estatística). A partir dos 15 dias, houve estabilização dos limiares de estimulação para os dois grupos, sem mudanças significativas até o final do acompanhamento. Não houve diferença na comparação das curvas dos dois grupos. CONCLUSÕES: Os eletrodos testados de fixação ativa e passiva eluídos com corticóides apresentaram parâmetros de sensibilidade e limiares de estimulação semelhantes entre si, enquanto que o eletrodo passivo apresentou-se com impedâncias maiores em todas as medidas. Para os dois eletrodos houve alterações significativas de limiares e impedância até 15 dias pós-implante seguido de estabilização até o final do período. Estes achados podem ter implicações na seleção do eletrodo, no agendamento das revisões e na programação do marcapasso.
24

Estudo comparativo entre a ultra-sonografia transvaginal e a transabdominal no crescimento folicular ovariano

Magalhães, Jose Antonio de Azevedo January 1989 (has links)
Resumo não disponível.
25

Mediadores inflamatórios no transtorno bipolar

Brietzke, Elisa Macedo January 2010 (has links)
Objetivos: Comparar os níveis séricos de citocinas entre voluntários saudáveis e em pacientes bipolares tipo 1 em mania, depressão e eutimia. Comparar os níveis séricos de quimiocinas entre voluntários saudáveis e pacientes bipolares tipo 1 em eutimia. Metodologia: Sessenta e um pacientes bipolares foram recrutados para a avaliação dos níveis séricos de citocinas. Desses, 24 estavam eutímicos, e 23 e 24 estavam em mania e depressão, respectivamente. Este grupo foi comparado a outro, composto por 25 voluntários saudáveis. As seguintes citocinas foram exainadas através de citometria de fluxo: TNF-alfa, IL-2, IL-4, IL-6, IL-10, IFN-gama e comparadas entre os grupos. Além dessa análise, 30 pacientes bipolares tipo 1 foram comparados a igual número de voluntários saudáveis para estudar os níveis séricos das seguintes quimiocinas: CCL2, CCL3, CCL8, CCL 9, CCL10, CCL11 e CCL24, dosadas através de ELISA sandwich. Resultados: Duarnte a mania, as citocinas pró-inflamatórias IL-2, IL-4 e IL-6 estavam elevadas nos pacientes com TB em comparação com o grupo de voluntários saudáveis. Já os pacientes em episódio depressivo, apresentavam somente elevação da IL-6. Não houve modificação dos níveis de citocinas nos pacientes eutímicos, exceto pelo aumento da IL-4. Quanto as quimiocinas, enquanto os níveis séricos de CXCL10 estavam elevados nos pacientes bipolares, os níveis de CCL24 estavam diminuídos. / Objectives: Compare serum levels of cytokines between healthy volunteers and patients with bipolar disorder type 1 in mania, depression and euthymia. Compare serum levels of chemokines between healthy volunteers and bipolar patients in euthymia. Methods: Sixty-one bipolar patients were recruited for assessment of serum cytokine levels. Of these, 14 were in euthymic state, 23 and 24 were in manic and depressive episodes, respectively. A healthy comparison group included 25 healthy volunteers. Cytokines involved in Th1/Th2 balance, such as TNF- , IL-2, IL-4, IL-6, IL-10, IFN- , were examined by flow cytometry. In addition, serum chemokine levels of 30 euthymic patients with BD type I and 30 healthy volunteers were investigated and compared. The chemokines assessed were CCL2, CCL3, CCL8, CCL 9, CCL10, CCL11, and CCL24. Results: During mania, proinflammatory cytokines, IL-2, IL-4 and IL-6, were increased in comparison with healthy subjects. Patients in depressive episode showed only increased IL-6 levels. There were no significant differences in cytokine levels between patients in remission and healthy subjects, except for IL-4. Regarding chemokines, patients with BD showed significant differences in chemokine levels when compared with healthy subjects. While serum levels of CXCL10 were increased, CCL24 levels were lower in bipolar patients when compared with controls. There was no statistical difference in the serum levels of CCL2, CCL3, CCL24, CXCL9, and CXCL11 between patients and controls.
26

Estudo comparativo entre as tecnicas de voltametria em pulso diferencial, Espectrofotometria no ultravioleta e visivel e Cromatografia liquida de alta eficiencia como metodologias analiticas no doseamento da substancia quimica Paracetamol

Santos, Luciana Oliveira dos. January 2003 (has links)
Mestre -- Instituto Nacional de Controle de Qualidade em Saude, Rio de Janeiro, 2003.
27

Mediadores inflamatórios no transtorno bipolar

Brietzke, Elisa Macedo January 2010 (has links)
Objetivos: Comparar os níveis séricos de citocinas entre voluntários saudáveis e em pacientes bipolares tipo 1 em mania, depressão e eutimia. Comparar os níveis séricos de quimiocinas entre voluntários saudáveis e pacientes bipolares tipo 1 em eutimia. Metodologia: Sessenta e um pacientes bipolares foram recrutados para a avaliação dos níveis séricos de citocinas. Desses, 24 estavam eutímicos, e 23 e 24 estavam em mania e depressão, respectivamente. Este grupo foi comparado a outro, composto por 25 voluntários saudáveis. As seguintes citocinas foram exainadas através de citometria de fluxo: TNF-alfa, IL-2, IL-4, IL-6, IL-10, IFN-gama e comparadas entre os grupos. Além dessa análise, 30 pacientes bipolares tipo 1 foram comparados a igual número de voluntários saudáveis para estudar os níveis séricos das seguintes quimiocinas: CCL2, CCL3, CCL8, CCL 9, CCL10, CCL11 e CCL24, dosadas através de ELISA sandwich. Resultados: Duarnte a mania, as citocinas pró-inflamatórias IL-2, IL-4 e IL-6 estavam elevadas nos pacientes com TB em comparação com o grupo de voluntários saudáveis. Já os pacientes em episódio depressivo, apresentavam somente elevação da IL-6. Não houve modificação dos níveis de citocinas nos pacientes eutímicos, exceto pelo aumento da IL-4. Quanto as quimiocinas, enquanto os níveis séricos de CXCL10 estavam elevados nos pacientes bipolares, os níveis de CCL24 estavam diminuídos. / Objectives: Compare serum levels of cytokines between healthy volunteers and patients with bipolar disorder type 1 in mania, depression and euthymia. Compare serum levels of chemokines between healthy volunteers and bipolar patients in euthymia. Methods: Sixty-one bipolar patients were recruited for assessment of serum cytokine levels. Of these, 14 were in euthymic state, 23 and 24 were in manic and depressive episodes, respectively. A healthy comparison group included 25 healthy volunteers. Cytokines involved in Th1/Th2 balance, such as TNF- , IL-2, IL-4, IL-6, IL-10, IFN- , were examined by flow cytometry. In addition, serum chemokine levels of 30 euthymic patients with BD type I and 30 healthy volunteers were investigated and compared. The chemokines assessed were CCL2, CCL3, CCL8, CCL 9, CCL10, CCL11, and CCL24. Results: During mania, proinflammatory cytokines, IL-2, IL-4 and IL-6, were increased in comparison with healthy subjects. Patients in depressive episode showed only increased IL-6 levels. There were no significant differences in cytokine levels between patients in remission and healthy subjects, except for IL-4. Regarding chemokines, patients with BD showed significant differences in chemokine levels when compared with healthy subjects. While serum levels of CXCL10 were increased, CCL24 levels were lower in bipolar patients when compared with controls. There was no statistical difference in the serum levels of CCL2, CCL3, CCL24, CXCL9, and CXCL11 between patients and controls.
28

Resposta do GH ao teste de estimulação com clonidina em pacientes com a síndrome dos ovários policísticos

Comim, Fabio Vasconcellos January 2003 (has links)
Resumo não disponível.
29

Análise morfométrica da parede arterial após o implante de stent em aorta abdominal de suínos : estudo comparativo entre stents metálicos não recobertos e recobertos com politetrafluoroetileno / Morphometric analysis of the arterial wall after stent deployment in the pig aorta : comparative study between naked and PTFE covered stainless steel stents

Grudtner, Marco Aurelio January 2001 (has links)
O espessamento intimal e a reestenose que ocorrem após os procedimentos de angioplastia transluminal percutânea e/ou o implante de stents representam uma causa freqüente de falência destes procedimentos. O principal achado patológico responsável pela reestenose parece ser a hiperplasia intimal, já que o dispositivo intravascular é resistente ao remodelamento arterial geométrico. O propósito deste estudo é avaliar, através da morfometria digital, o espessamento intimal presente nas regiões da parede arterial imediatamente proximal e distal ao implante de um stent metálico em configuração em “Z “ não recoberto ou recoberto com PTFE. Vinte e cinco suínos de raça mista, com seis a dez semanas de idade, pesando em média 20 kg foram divididos em três grupos. No grupo I, cinco animais foram submetidos à exposição cirúrgica retroperitoneal da aorta abdominal, aortotomia e manipulação com uma bainha introdutora de 12 F. O grupo II incluiu dez animais que foram submetidos ao implante de um stent metálico auto-expansível não recoberto. No grupo III, incluindo também dez animais, foram implantados stents recobertos com PTFE. Após quatro semanas, todos os animais foram sacrificados e o segmento aorto-ilíaco foi removido. Quatro animais foram excluídos do estudo por trombose da aorta (um animal do grupo II e três animais do grupo III). Para a análise morfométrica foram utilizados os testes não paramétricos de Wilcoxon e de Kruskal-Wallis, para as comparações, respectivamente, no mesmo grupo e entre os grupos. Foi adotado o nível de significância de 5% ( p< 0,05). Quando os espécimes da parede arterial, imediatamente proximal e distal aos stents foram comparados, nenhuma diferença estatisticamente significativa foi encontrada entre as áreas luminal, intimal, média ou índice intimal em cada grupo. Na comparação entre os grupos, as áreas intimal, média e o índice intimal não demonstraram variação estatisticamente significativa. Foram identificadas diferenças entre os grupos quanto às áreas luminais proximais (p = 0,036) e distais (p=0,044). Pelo teste de comparações múltiplas para Kruskal-Wallis (Teste de Dunn) identificou-se diferença significativa entre os grupos I e II. Entretanto, quando estas variáveis foram controladas pelo fator peso (relação área luminal/peso) a diferença não foi mais observada. Concluímos que, após quatro semanas, stents recobertos com PTFE induzem um espessamento intimal justa-stent similar ao observado com stents não recobertos ou com a simples manipulação arterial com uma bainha introdutora. Neste modelo experimental suíno, de curto seguimento, o revestimento com PTFE não foi responsável por adicional espessamento intimal. / Intimal thickening and restenosis occurring after angioplasty and/or stent deployment constitutes a frequent determinant of failure of these procedures. The main pathologic finding responsible for restenosis seems to be intimal hyperplasia, since the intravascular device is resistant to geometric arterial wall remodeling. The purpose of this study is to evaluate, by means of digital morphometry, the intimal thickening present in the regions of the arterial wall proximal and distal to the implant of a naked or PTFE covered stainless steel Z stent. Twenty five crossbred pigs, 6 to 10 weeks old, weighing between 14 and 32 kg (average= 20 kg) kg were divided in three groups. Group I included five animals that were submitted to retroperitoneal exposure of the aorta, aortotomy and simple insertion of a 12 F sheath. Group II included those animals in which a naked stent was deployed. Finally, in group III included the use of a PTFE covered stent. After four weeks, all animals were submitted to euthanasia and the aorto-iliac segment was removed. Four animals were excluded from the study due to aortic thrombosis (one from group II and three from group III). Morphometric analysis was performed using the non-parametric Wilcoxon and Kruskal-Wallis tests to compare data within the group, and across groups, respectively. When specimens of the arterial wall immediately proximal and distal to the stents were compared, no statistically significant difference could be established regarding luminal, intimal and media areas or intimal index. It was not possible to find significant differences between the intimal and medial areas or the intimal index. According to the Kruskal-Wallis test, a significant difference between proximal (p=0,036) and distal (p=0,044) luminal areas was observed between groups. The Dunn test identified differences between groups I and II. However, when these variables were corrected regarding the weight factor (luminal area/ weight index) this difference was no longer seen. We conclude that, after four weeks, covered PTFE stents generate an intimal thickening similar to uncovered stents or simple catheter manipulation. In this experimental model, the PTFE material was not responsible for additional intimal thickening during this limited period of time.
30

Resposta do GH ao teste de estimulação com clonidina em pacientes com a síndrome dos ovários policísticos

Comim, Fabio Vasconcellos January 2003 (has links)
Resumo não disponível.

Page generated in 0.0995 seconds