• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 349
  • 349
  • 218
  • 216
  • 46
  • 35
  • 34
  • 29
  • 26
  • 26
  • 25
  • 24
  • 23
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Fumo e permeabilidade de pequenas vias aéreas em jovens não-pneumopatas

Pereira, Rosemary Ricarda Petrik January 1975 (has links)
Resumo não disponível
62

Estudo comparativo das caracter?sticas cl?nicas e de indicadores de qualidade no tratamento dial?tico cr?nico em uma unidade de hemodi?lise privada do sul do Brasil

R?hsig, Vania 29 August 2011 (has links)
Made available in DSpace on 2015-04-14T13:35:17Z (GMT). No. of bitstreams: 1 434139.pdf: 857675 bytes, checksum: 88f7f7c2e97aef43ae427ecc117c13c3 (MD5) Previous issue date: 2011-08-29 / Este estudo busca comparar os indicadores de qualidade do tratamento dial?tico de pacientes em programa cr?nico de hemodi?lise em uma unidade privada do sul do Brasil com os indicadores de qualidade nacionais e tamb?m com os obtidos em pa?ses desenvolvidos. Foram coletados dados demogr?ficos, doen?as de base, acesso vascular e dados laboratoriais de pacientes que realizaram terapia de substitui??o da fun??o renal, na modalidade de hemodi?lise na unidade de di?lise do Hospital Moinhos de Vento (HMV), dados coletados e divulgados pelo Censo da Sociedade Brasileira de Nefrologia de 2007 e foram utilizados os dados do estudo Dialysis Outcomes and Practice Patterns Study 3. Os pacientes em programa cr?nico de hemodi?lise do HMV possuem diferentes caracter?sticas demogr?ficas, utilizam com maior freq??ncia o cateter venoso central como acesso vascular para hemodi?lise, possuem uma ferritina com maior concentra??o assim como maior freq??ncia de sorologia positiva para o virus da hepatite C. Quanto a adequa??o do tratamento dial?tico(Kt/V, albumina e hemoglobina), n?o houve diferen?as na compara??o com os indicadores do Brasil e dos pa?ses desenvolvidos
63

Estudo comparativo dos inibidores benzotriazol e tolitriazol na oxidação de materiais ferrosos em meio de ácido sulfúrico / Comparative study of benzotriazole and tolitriazole inhibitors in the oxidation of ferrous materials in sulfuric acid medium

Cunha, Maico Taras da 26 August 2003 (has links)
Foi feito um estudo comparativo da ação inibidora dos compostos benzotriazol (BTAH) e tolitriazol (TTAH) sobre a oxidação de metais ferrosos e sobre a reação H+/H2, sobre ferro, em meios de ácido sulfúrico. Foram estudados, como metais ferrosos, o ferro puro (99,9% de pureza), em meio de H2SO4 0,5molL-1, o aço carbono 1008, em H2SO4 0,5mol L-1e o aço inoxidável 304, em meio de H2SO4 4,5 mol L-1. Foram empregadas, como técnicas, medidas de potencial de circuito aberto em função do tempo, ensaios gravimétricos, curvas de polarização potenciostáticas, voltametria linear com eletrodo parado e com eletrodo de disco rotativo, cronoamperometria, espectroscopia por impedância eletroquímica, espectroscopia Raman e microscopia eletrônica de varredura (MEV). Os compostos BTAH e TTAH atuaram como inibidores para os três materiais ferrosos estudados. No caso do aço carbono 1008 e do aço inoxidável 304, os efeitos dos dois inibidores se comparam e, para uma concentração igual a 1,0 x 10-2 mol L-1 apresentam uma eficiência máxima de 98%, verificada por técnicas estacionárias e não estacionárias. O TTAH, em mais baixa concentração, se mostrou melhor inibidor para o aço carbono, enquanto para o aço inoxidável 304 foi tão bom inibidor quanto o BTAH. Análise das superfícies por MEV mostrou que os inibidores não impedem a dissolução das inclusões presentes nos aços estudados, permitindo o ataque localizado no entorno das mesmas, no caso do aço 304. Os compostos BTAH e TTAH se mostraram inibidores menos efetivos para o ferro, com eficiências comparáveis e iguais a 60% na concentração mais elevada estudada, 1,0 x 10-2 mol L-1 . O estudo da oxidação do ferro, na região de Tafel, empregando impedância eletroquímica, mostrou que o BTAH e o TTAH atuam de forma comparável, formando um complexo com o intermediário Fe (II) adsorvido. Ensaios por espectroscopia Raman in situ revelaram que há formação de complexos de ferro com o BTAH e TTAH. Os resultados de impedância eletroquímica, juntamente com os de espectroscopia Raman do complexo Fe(II)BTA sólido levaram à conclusão de que o filme inibidor sobre ferro é o próprio complexo Fe(II)BTA. Estudos de polarização catódica sobre ferro, em meio desaerado, mostraram que tanto o BTAH quanto o TTAH inibem a reação H+/H2, através da formação de um filme que obedece à isoterma de adsorção de Langmuir. Valores de ΔGº de adsorção sugerem que a adsorção é de natureza química, o que foi confirmado por espectroscopia Raman. Estudos empregando voltametria de baixa velocidade de varredura, com eletrodo de disco rotativo, mostraram que a ação inibidora é favorecida pelo maior transporte de massa à superfície do eletrodo de ferro. Os resultados de impedância permitiram sugerir dois diferentes mecanismos para a ação dos inibidores sobre o processo de oxidação do ferro em meio de ácido sulfúrico. / A comparative study of the inhibitor behavior of benzotriazol (BTAH) and tolitriazol (TTAH) over the oxidation of ferrous metals and over the reaction H+/H2, over iron in sulfuric acid media has been performed. The ferrous metals studied were pure Iron (99.9% purity) and carbon steel 1008, both in 0.5 mol.L-1 H2SO4 and 304 stainless steel in 4.5 mol.L-1 H2SO4. The techniques employed were, open circuit potential vs. time, gravimetry, potentiostatic polarization curves, linear voltammetry with both stationary and rotating disk electrodes, chronoamperometry, electrochemical impedance spectroscopy, Raman spectroscopy and scanning electron microscopy (SEM). BTAH and TTAH have shown to act as inhibitors for the three studied ferrous metals. The inhibiting effect of these compounds was analogous for both carbon steel 1008 and 304 stainless steel. Furthermore stationary and non-stationary techniques have shown that both inhibitors exhibited the maximum of efficiency (98%) in 1.0 x 10-2 mol.L-1. For the lowest studied concentration, TTAH exhibited a better inhibiting effect over the carbon steel, while for the 304 stainless steel TTAH and BTAH presented the same inhibiting efficiency. SEM Analysis of the surfaces showed that the inhibitors do not avoid the dissolution of the inclusions that exist in the studied steels, instead, for 304 stainless steel they permit a localized attack on the contour of the inclusions. Both BTAH and TTAH have shown a less effective inhibitory effect for iron with 60% of efficiency for the highest studied concentration (1.0 x 10-2 mol.L-1). The study of the oxidation of iron performed on the Tafel region by electrochemical impedance spectroscopy showed that both BTAH and TTAH act similarly, forming a complex with the adsorbed intermediary Fe(II). Raman spectroscopy measurements performed in situ indicated the formation of iron complexes with BTAH and TTAH. The analysis of the results obtained for the complex Fe(II)BTA with both electrochemical impedance spectroscopy and Raman spectroscopy techniques revealed that this complex forms the inhibitor film. Cathodic polarization studies performed for iron in dearated media showed that both BTAH and TTAH forma film that obeys to the Langmuir adsorption isotherm on the iron surface which inhibits the H+/H2 reaction. Furthermore ΔGº adsorption values suggest that the adsorption is chemical in nature which was confirmed by Raman spectroscopy. Low rate voltammetry studies performed with rotating disk electrode, showed that the inhibitory effect is favored by the mass transport towards the iron electrode surface. From the impedance spectroscopy results two different mechanisms could be proposed to the inhibitor effect over the process of iron oxidation in sulfuric acid media.
64

Resistência das vias aéreas : técnica do interruptor versus pletismografia : uma nova abordagem

Gritti, Leandro Antonio January 2010 (has links)
Fundamentação: A resistência das vias aéreas (Rva) é a diferença de pressão entre o alvéolo e a boca dividida pela taxa de fluxo. Este parâmetro pode ser obtido pela pletismografia, técnica mais complexa e disponível em poucos centros. O método do interruptor (Rint) é simples, de fácil execução, exigindo pouca colaboração, portátil, baixo custo relativo à pletismografia. Em crianças há valores de referência e correlação com a técnica pletismográfica. Em adultos existem poucos dados de correlação. Objetivo: Avaliar a concordância da Rva pelo método do Rint com o método pletismográfico. Método: As medidas de Rint foram feitas na expiração, em posição sentada, com clipe nasal e suporte das bochechas. O exame pletismográfico foi realizado da maneira habitual. Realizamos medidas de comparação entre os métodos antes e após a administração inalatória de broncodilatador. Resultados: Analisamos um total de 87 pacientes de 18 a 82 anos de idade, sendo 52,5% mulheres. Houve concordância entre os métodos (r=0,8 e ICC=0,8) para pacientes com VEF1% ≥ 60. O Rint também teve boa concordância com a pletismografia no diagnóstico de aumento da resistência das vias aéreas, notadamente para medidas de Rint ≥4 cm/H2O/L/s (RV >8 e índice Kappa 0,73). Conclusão: O presente estudo identificou que a concordância entre o Rint e a pletismografia é boa em indivíduos menos graves (VEF1%≥60). A concordância no diagnóstico de aumento ou normalidade da Rva entre os dois métodos foi forte. O Rint é um método potencialmente útil na prática assistencial em adultos.
65

Teste do suor para diagnóstico de fibrose cística: comparação do teste clássico com o teste simplificado / Sweat test for the diagnosis of cystic fibrosis: comparison between the classic and a simplified test

Ana Claudia Veras Mattar 08 June 2010 (has links)
INTRODUÇÃO: apesar da identificação de mais de 1500 mutações para o gene CFTR (cystic fibrosis transmembrane conductance regulator), o teste do suor ainda é o teste diagnóstico para Fibrose Cística (FC). O teste quantitativo de iontoforese por pilocarpina (TQIP) é o padrão-ouro para coleta do suor e análise do cloro, mas está sujeito a erros se não for realizado por técnicos qualificados. Embora a técnica de coleta do suor pelo sistema macroduct® e análise pela condutividade seja simples e tenha boa correlação com os níveis de cloro em estudos prévios, a mesma ainda é considerada como um teste de triagem para FC. O melhor ponto de corte para confirmar ou afastar a FC pelo método da condutividade deve ser ainda estabelecido. OBJETIVOS: comparar os valores de cloro no suor obtidos pelo teste quantitativo da iontoforese pela pilocarpina (teste clássico) com os valores de condutividade do suor obtido pelo sistema de coleta por macroduct® (teste simplificado) em pacientes com e sem FC e em uma amostra aleatória de pacientes em investigação para FC. O custo e o tempo despendidos na execução de cada teste foram também analisados na fase inicial do estudo. MÉTODOS: o teste do suor, pelas duas técnicas, foi realizado simultaneamente em pacientes com e sem FC e posteriormente em pacientes em investigação diagnóstica da doença no período de fevereiro/2006 a outubro/2008. Os pontos de corte para a condutividade para excluir ou diagnosticar FC foram < 75 e ? 90 mmol/L, respectivamente, e para o teste clássico cloro ? 60 e > 60 mmol/L. Na fase inicial da pesquisa (casos com e sem FC) foram utilizadas tabelas de contingência para os cálculos de sensibilidade (S), especificidade (E), valor preditivo positivo (VPP) e negativo (VPN), além do teste exato de Fisher para avaliar a associação entre os testes e a presença ou ausência de FC. Na amostra aleatória de pacientes usou-se a curva ROC também para os cálculos de S, E, VPP e VPN e também para calcular a área sob a curva entre os testes, e, em ambas as fases da pesquisa, para avaliar sua acurácia. Os respectivos intervalos de confiança de 95% (IC95%) também foram analisados. Para avaliação da concordância entre os testes, na amostra aleatória de pacientes, utilizou-se o coeficiente de kappa e o teste de McNemar. Aplicou-se o teste de Wilcoxon para se comparar os tempos na execução de cada teste, sendo considerados significativos quando p<0,05. RESULTADOS: 52 pacientes com FC (29M/23F; 1,5 a 18,2 anos) realizaram o teste do suor pelas duas técnicas, apresentando valores medianos de cloro e condutividade no suor de 114 e 122 mmol/L, respectivamente. A condutividade foi ? 95 mmol/L em todos os pacientes, conferindo ao teste 100% de sensibilidade (IC95%: 93,1 a 100%). Cinquenta pacientes sem FC (24M/26F; 0,5 a 12,5 anos) apresentaram valores medianos de cloro e condutividade no suor de 15,5 e 30 mmol/L, respectivamente. Em todos os casos a condutividade foi < 70 mmol/L, conferindo ao teste 100% de especificidade (IC95%: 92,9 a 100%). Foram então realizados 918 testes nos pacientes em investigação para FC, mas, em 180, as amostras foram inadequadas. Dos 738 testes realizados pelas duas técnicas, em 714 pacientes se afastou a FC, encontrando-se mediana de cloro de 11 mmol/L (variação: 3 a 137 mmol/L) e de condutividade de 25 mmol/L (variação: 14 a 138 mmol/L). Foram confirmados 24 pacientes com FC, encontrando-se uma mediana de cloro de 87 mmol/L (variação: 54 a 132 mmol/L) e de condutividade de 103 mmol/L (variação: 50 a 126 mmol/L). Pela curva ROC, com valores de condutividade > 90 mmol/L, obteve-se S= 83,3%, E= 99,7%, VPP= 90,9% e VPN= 99,4% para o diagnóstico de FC. Com valores de condutividade < 75 mmol/L praticamente se pôde excluir o diagnóstico de FC (VPN=99,7%; IC95%:99,0-100%). Houve excelente concordância entre o teste clássico e o simplificado, tanto pelo valor de kappa (0,934; IC95% 0,86 a 1,009), quanto pelo teste de McNemar (p=1,0000). O tempo despendido na execução dos testes foi significativamente menor com o teste simplificado (p<0,0001) e o custo do método simplificado foi discretamente inferior. CONCLUSÕES: o teste da condutividade do suor, seja em pacientes com diagnóstico previamente conhecido (com ou sem FC) ou quando realizado aleatoriamente, mostrou resultados superponíveis ao teste clássico e foi capaz de diferenciar pacientes com e sem FC. O teste simplificado apresentou alta sensibilidade e especificidade e houve excelente concordância entre os testes. O tempo de execução foi mais rápido e o custo inferior ao teste clássico. / INTRODUCTION: despite the identification of over 1500 CFTR (cystic fibrosis transmembrane conductance regulator) gene mutations, the sweat test is still the diagnostic test for cystic fibrosis (CF). The quantitative pilocarpine iontophoresis test (QPIT) is the gold-standard method for collection of sweat and chloride analyses, but is subjected to errors if not performed by qualified technicians. Although the technique using the macroduct system for sweat collection and the conductivity analysis is simpler and has good correlation with chloride levels in previous studies, it is still considered a screening test for CF. The best cut-off point of sweat conductivity to confirm or rule out CF must yet be established. OBJECTIVES: to compare the sweat chloride values obtained by the quantitative pilocarpine iontophoresis test (classic test) with sweat conductivity analysis obtained by the macroduct (simplified test) in patients with a confirmed CF diagnosis, in patients without CF and in a random sample of patients being investigated for CF. The cost and time spent to perform each test were also analysed in the initial phase of the study. METHODS: both techniques of sweat test were simultaneously performed initially in patients with CF, afterwards in patients in whom CF had been ruled out and finally in patients referred for a sweat test between February 2006 and October 2008. The cut-off values for sweat conductivity to exclude or diagnose CF were = 90 mmol/L and for the QPIT were sweat chloride ? 60 e > 60 mmol/L, respectively. Contingency tables were used in the initial phase of the study (cases with or without CF) for calculation of sensitivity (Se), specificity (Sp), positive (PPV) and negative predictive value (NPV) and Fisher\'s exact test was used to assess the association between the tests and the presence or absence of CF. ROC curve was used in the random sample of patients also for calculation of Se, Sp, PPV and NPV and also to calculate the area under the curve between both tests in both phases of the study to assess their accuracy. The respective 95% confidence intervals (95%CI) were also analysed. Kappa coefficient and McNemar tests were used for evaluation of agreement between the tests in the random sample of patients. Wilcoxon test was used to compare the time spent to perform each test, with the significant difference set at p < 0.05. RESULTS: in 52 CF patients (29M/23F, age range 1.5 to 18.2y) the median value of sweat Cl and conductivity were 114 and 122 mmol/L, respectively. All patients had sweat conductivity values above 95 mmol/L (100% sensitivity; 95%CI: 93.1 to 100%). In 50 patients without CF (24M/26F, age range 6m to 12.5y) the median value of sweat Cl and conductivity were 15.5 and 30 mmol/L, respectively. All patients had conductivity values bellow 70 mmol/L (100% specificity; 95%CI: 92.9 to 100%). Nine hundred and eighteen tests were then performed in patients being investigated for CF but 180 had inadequate samples. Of the 738 tests performed with both techniques in 714 CF was ruled out, with median values of sweat Cl of 11 mmol/L (range: 3 to 137 mmol/L) and of conductivity of 25 mmol/L (range: 14 to 138 mmol/L). Twenty four patients had a diagnosis of CF presenting a median sweat Cl of 87 mmol/L (range: 54 to 132 mmol/L) and a median conductivity value of 103 mmol/L (range: 50 to 126 mmol/L). The ROC curve showed that with a conductivity value > 90 mmol/L sensitivity of 83.3%, specificity of 99.7%, PPV of 90.9% and NPV of 99.4% was obtained to diagnose CF. The best conductivity cut-off value to exclude CF was < 75 mmol/L (NPV=99.7%; IC95%:99.0-100%). Good agreement were observed between the tests (kappa: 0.934; IC95% 0.86 a 1.009; McNemar test: p=1.0000). The time spent to perform the tests was significantly lower with the simplified test (p<0.0001) and the cost was slightly lower with the conductivity test. CONCLUSIONS: sweat conductivity performed in patients with a known CF or non-CF diagnosis or randomly applied in subjects referred for a sweat test showed similar results as the classic test and could differentiate patients with or without CF. Conductivity test had a high sensitivity and specificity and good agreement was observed between the techniques. The time spent to perform the tests was lower with the simplified test, as well as the cost.
66

Estudo comparativo da viabilidade miocárdica em áreas dissinérgicas ao ecocardiograma basal : cintilografia tomográfica com Tecnécio 99m-mibi sob baixa dose de Dobutamina versus Tálio em repouso-redistribuição

Pilger Filho, Egon Pedro January 2000 (has links)
A cintilografia com radioisótopos em repouso tem despertado muito interesse nos últimos anos para pesquisa da viabilidade miocárdica na disfunção isquêmica avançada do VE, porque esta pode ser reversível e porque há melhora prognóstica neste contexto. O objetivo desse trabalho é buscar identificar a acurácia da cintilografia tomográfica Tc-99m-Sestamibi, sob a infusão de dobutamina em baixa dose. Foram protocolados trinta pacientes que sofreram um infarto do miocárdio com padrão “Q”, com dissinergia ao ecocardiograma, e submetidos a estudos perfusionais em dias diferentes, com Tc-99m-Sestamibi − dobutamina e Tl-201 em repouso-redistribuição 4 horas, usado como padrão ouro. Não ocorreram complicações com nenhum paciente submetido ao protocolo do estudo. Os resultados revelaram: sensibilidade = 85%, especificidade = 87%, valor preditivo positivo = 96%, valor preditivo negativo = 65 % e acurácia de = 85,2%. A razão de probabilidade positiva foi de 6,68 e a razão de probabilidade negativa de 0,17. Confrontando-se nossos dados com uma metanálise de resultados para o Tc-99m-Sestamibi em repouso, a sensibilidade no presente estudo foi 85% vs. 81% e a especificidade de 87% vs. 60%. Em relação aos dados da literatura para Tl-201: 85% vs. 90% e 87% vs. 54%, sensibilidade e especificidade, respectivamente. Em conclusão, o Tc-99m-Sestamibi sob a infusão de dobutamina parece ser um método promissor para detectar viabilidade superior a esta modalidade de cintilografia em repouso, com valores preditivos comparáveis à literatura disponível para esse mesmo método: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, para acurácia, valor preditivo positivo e valor preditivo negativo, respectivamente. / Rest isotopic scintigraphy has been evoked much interest in the last years for myocardial viability search on severe ischemic ventricular dysfunction, because improvement of function can bring a better outcome to this subset of acute myocardial infarction (MI) survivors. This study was designed to search to identify accuracy of 99m-Tc sestamibi − low dose dobutamine SPECT scintigraphy in a single injection rest protocol examination. Thirty patients with previous Q wave (MI), with basal echocardiographic demonstration of rest dyssynergia and coronary artery related significant obstruction, were submitted to perfusion studies, on a different day basis, with 99m-Tc-sestamibi − dobutamine and 201-Th rest-redistribution, utilized as gold standard. There were not complications with any patient submitted to this study protocol. The results showed sensitivity = 85%, specificity = 87%, positive predictive value = 96%, negative predictive value = 65% and accuracy = 85.2%. The positive likelihood ratio was 6.68 and the negative likelihood ratio 0.17. When our results were confronted with a metanalysis 99m-Tc sestamibi at rest (our results being firstly showed), sensitivity was 85% vs. 81%, specificity 87% vs. 60%, respectively. In relation to literature data for 201-Thallium were 85% vs. 90% e 87% vs. 54%, for sensitivity, specificity, respectively. In conclusion, 99m-Tc sestamibi-low dose dobutamine seems to be a promising test to detect viability, superior to that modality of rest perfusion, with predictive values comparable to the available literature for this methodology: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, results for accuracy, positive predictive value and negative predictive value, respectively.
67

Análise morfométrica digital na parede aórtica de suínos após implante de stents não revestidos versus stents revestidos com dacron / Digital morphometric analysis on the aortic wall of pigs after implants of non coated stents versus coated stents with dacron

Dutra, Clandio de Freitas January 2001 (has links)
Os stents são dispositivos intravasculares implantados com o objetivo de dilatar ou fixar a placa de colesterol contra a parede arterial. O objetivo avaliar dois tipos de stents de aço inoxidável, um recoberto com poliéster (dacron) e outro não recoberto, implantados na aorta infra-renal de suínos jovens, foram avaliados por morfometria digital para medir o espessamento intimal. Foi realizado um estudo experimental randomizado, separados em dois grupos(stents não revestidos e revestidos com dacron) e duas fases (I e II). Oito stents recobertos com dacron e oito stents de aço inoxidável (30mm de extensão e 8 mm de diâmetro), não revestidos, foram implantados através de abordagem retroperitoneal na aorta infrarenal normal de 16 suínos normolipêmicos. Para a passagem do sistema de implante, foi necessário uma pequena arteriotomia na aorta distal (fase I). Após quatro semanas, a aorta com os stents foram removidas em monoblocos (fase II). Os valores de hematimetria e do lipidograma foram coletados nas duas fases e não apresentaram alterações que pudessem influenciar o estudo. Amostras de tecido dos sítios de fixação (proximal e distal) dos stents foram retiradas, confeccionadas lâminas, que foram coradas pelas técnicas de hematoxilina e eosina de Verhoeff e enviadas para análise morfométrica digital. A camada intima distal não apresentou diferença estatística significativa. A camada média proximal das porções proximal e da porção distal não apresentaram diferença entre os grupos. Os dois tipos de stents apresentaram 100% de perviedade, boa biocompatibilidade e boa incorporação a parede aórtica de suínos normolipêmicos. A camada íntima proximal do grupo de stents revestidos com dacron apresentou espessura maior do que os stents não revestidos, mas com significância estatísitica limítrofe. / Stents are intravascular devices implanted with the objective of dilating or fixing the cholesterol plate against the arterial wall. To evaluate, by digital morphometry, the intimal thickening after the placement of two different kinds of stents: polyester covered stainless steel stents (Dacron) and non-covered stents implanted in young pigs’ infrarenal aortas. The stents were made at the Biotransformation Laboratory of Federal University of Rio Grande do Sul. The experiment was performed at the Biotério of University of Caxias do Sul, carried out on two separate groups of pigs. Eight polyester-covered stainless steel stents (Dacron) and eight stainless steel stents (30-mm long, 8-mm diameter) were deployed through extraperitoneal approach in the normal infrarenal aorta of 16 normolipemic pigs. To allow the passage of the delivery system, a small arteriotomy was performed (phase I). After four weeks, the aorta with the stent was removed en bloc. (phase II). The values of the hematimetric and lipid analysis did not show any changes that could influence the study. Tissue samples of the fixing sites (proximal and distal) of the stents were taken. Microscope slices were prepared and submitted to Verhoeff’s hematoxilin and eosin techniques and sent to morphometric analysis.The intima immediately proximal to the device was thicker in the group of covered stents with marginal significance. The distal intimal layer, proximal medial layer of the proximal portion and distal portion did not present statistical difference between the two groups. Patency was 100% in both groups of these normolipemic pigs. After four weeks the intimal layer immediately proximal to the covered stents was ticker when compared to uncovered stents, but this had a borderline significance. The intimal layer distal to covered stents and the media proximal or distal to the devices had similar morphometric features when covered and uncovered stents where compared.
68

Gravidez na adolescência : como se configura no Brasil e em Portugal?

Dei Schirò, Eva Diniz Bensaja January 2009 (has links)
O presente estudo teve como objectivo investigar as características biosociodemográficas associadas à gravidez durante a adolescência. Para isso foram realizados dois estudos: um quantitativo (N = 452) e outro qualitativo (N = 8). No primeiro investigou-se a gravidez em adolescentes brasileiros de 10 cidades (n = 226) na relação com a escola, trabalho, família e amigos. Foram, também, investigados aspectos da vida sexual e da utilização de métodos contraceptivos. Essas mesmas variáveis foram analisadas num grupo de comparação sem a experiência de gravidez (n = 226), pareados pelas variáveis sexo, idade e cidade. Os resultados obtidos revelaram a ausência de diferenças significativas para a escolaridade e o trabalho (p>0,05). Contudo verificou-se que os adolescentes com experiência de gravidez tinham um maior número de reprovações e estudavam mais no turno da noite. As diferenças entre os grupos foram obtidas na utilização de contracepção, na relação com a família e amigos. O grupo com experiência de gravidez demonstrou ter uma menor utilização de métodos contraceptivos, em comparação ao outro grupo. Além disso, revelou um menor nível de apoio e confiança na sua família, assim como, revelou ter menos amigos. No segundo estudo foram investigadas qualitativamente as mesmas variáveis do Estudo I, em adolescentes grávidas no Brasil (n = 4) e em Portugal (n = 4). A gravidez surgiu em relações estáveis e foi descrita como um acontecimento importante, mesmo quando inesperado. Muitas das adolescentes entrevistadas já não frequentavam a escola e desenvolviam uma actividade de trabalho. O contexto social de desenvolvimento sobressaiu como um factor importante para a emergência da gravidez durante a adolescência. Face ao exposto considerou-se que os resultados qualitativos corroboraram aqueles que foram obtidos de forma quantitativa. / The aim of this study was to investigate biosociodemographic characteristics associated with adolescent pregnancy. For that reason, two different studies were performed: a quantitative (N = 452) and a qualitative (N = 8). Firstly, it was investigated pregnancy among Brazilian adolescents of 10 cities of the country (n = 226) and their relationship with school, work, family and friends. Secondly, it was investigated characteristics of their sexual life and contraceptive use. These same variables were examined at one equivalent group - without pregnancy experience (n = 226). These samples were paired according to sex, age and city. The results revealed that there were not significant differences between groups, regarding education and work (p>0,05). Although, it was observed that group with pregnancy experience had more failed results at school and studied more at night shift. The use of contraceptive methods and the relationship with family and friends was an intergroup difference. In the group with pregnancy experience, precarious use of contraceptive methods was presented in comparison with the other group. Moreover this group revealed a worse level of support and confidence in their family and reported to have fewer friends. In the Study II, it was investigated, based on qualitative methods, the same variables of the Study I, regarding pregnant adolescents in Brazil (n = 4) and in Portugal (n = 4). Pregnancy appeared during stable relationships, and it was described as an important life event, even when unexpected. Some adolescents did not go to school when they got pregnant, and entered in a labour activity. The social context of development appeared as an important factor to the emergence of adolescence pregnancy. The results that derived from qualitative analysis corroborated those obtained from quantitative ones.
69

"Perfil comportamental e competência social de crianças e adolescentes filhos de mulheres com esquizofrenia" / Behavior profile and social competence of children and adolescentes of schizophrenic mothers

Gutt, Elisa Kijner 14 December 2005 (has links)
Este estudo teve como objetivo avaliar o perfil comportamental e a competência social de crianças e adolescentes, filhos de mulheres com esquizofrenia, e compará-los com crianças da mesma faixa etária e sexo, filhos de mulheres sem transtorno mental grave. Para a avaliação das crianças e adolescentes foram utilizados o Inventário de Comportamentos para Infância e Adolescência (Child Behavior Checklist- CBCL) e o Inventário de Comportamentos Auto-Referidos para Adolescentes (Youth Self Report- YSR). Os filhos de mulheres com esquizofrenia apresentaram maior proporção de problemas de internalização e de problemas com o pensamento, principalmente para as crianças que moravam com a mãe com esquizofrenia, quando comparados a crianças e adolescentes do grupo comparativo com mães sem transtornos mentais / The objective of this study was to evaluate the behavior profile and social competence of children and adolescents of schizophrenic mothers, and compare it with children of the same age and gender of mothers without any severe mental disorder. To evaluate children and adolescents the Child Behavior Checklist (CBCL) and Youth Self Report (YSR) were used. The children of schizophrenic mothers had a higher proportion of internalizing problems and of thought problems, mostly for children living with their schizophrenic mothers, when compared to children and adolescents of mothers without any psychiatric disorder
70

Avaliacao da efetividade do protocolo de acompanhamento odontologico dos radioacidentados com o cesio-137 em Goiania-Goias, no periodo de 1988-2001

Wascheck, Carla de Camargo. January 2002 (has links) (PDF)
Especialista -- Universidade Federal de Goias. Faculdade de Odontologia, Goiania, 2002.

Page generated in 0.0974 seconds