• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • Tagged with
  • 20
  • 12
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Funções estruturais e regulatórias das regiões N- e C-terminal da troponina I / Structural and Regulatory Functions of the NH2- and COOH-terminal Regions of Skeletal Muscle Troponin I

Farah, Chuck Shaker 13 June 1994 (has links)
O complexo troponina-tropomiosina regula a contração muscular esquelética e cardíaca. A ligação do cálcio nos sítios regulatórios localizados no domínio N-terminal da troponina C (TnC) induz uma mudança conformacional que remove a ação inibitória da troponina I (TnI) e inicia a contração muscular. Nós usamos fragmentos recombinantes da TnI e uma série de mutantes da TnC para estudar as interações estruturais e regulatórias das diferentes regiões da TnI com os domínios da TnC, TnT e actina-tropomiosina. Nossos resultados indicam que a TnI é organizada em regiões que apresentam funções estruturais e regulatórias e que se ligam de modo antiparalelo com os correspondentes domínios estruturais e regulatórios da TnC. Estudos funcionais mostram que a região inibitória (aminoácidos 103-116) em combinação com a região C-terminal da TnI (TnI103-182) pode regular a atividade ATPásica da acto-miosina de maneira dependente de Ca2+. A regulação não é observada com a região inibitória em combinação com a região N-terminal (TnI116) Estudos de ligação mostram que a região N-terminal da TnI (TnI1-98) interage com o domínio C-terminal da TnC na presença e na ausência de Ca2+ e também interage com a TnT. A região inibitória/C-terminal da TnI (TnI103-182) interage com o domínio N-terminal da TnC de maneira dependente de Ca2+. Baseados nestes resultados, propomos um modelo para a mudança conformacional induzida pelo Ca2+. Neste modelo, a região N-terminal da TnI está ligada fortemente com o domínio C-terminal da TnC na presença ou na ausência de Ca2+. As regiões inibitórias e C-terminal da TnI ligam-se à actina-tropomiosina na ausência de Ca2+ e nos domínios N-terminal e C-terminal da TnC na presença de Ca2+. / The troponin-tropomyosin complex regulates skeletal and cardiac muscle contraction. Calcium binding to the regulatory sites in the N-terminal domain of troponin C (TnC). induces a conformational change which removes the inhibitory action of troponin I (TnI) and initiates muscular contraction. We used recombinant TnI fragments and a series of TnC mutants to study the structural and regulatory interactions between different TnI regions and the domains of TnC, TnT and actin-tropomyosin. Our results indicate that TnI is organized into regions with distinct structural and regulatory functions which bind, in an antiparallel manner, with the corresponding structural and regulatory domains of TnC. Functional studies show that a fragment containing the inhibitory and C-terminal regions of TnI (TnIl03-182) can regulate the actomyosin ATPase in a Ca2+- dependent manner. Regulation was not observed with a fragment containing the N-terminal and inhibitory regions (TnIl-116). Binding studies show that the N-terminal region of TnI (TnI1-98) interacts with the C-terminal domain of TnC in the presence of Ca2+ or Mg2+. The inhibitory/C-terminal region of TnI (TnI103-182) binds to the N-terminal domain of TnC in a Ca2+-dependent manner. Based on these results, we propose a model for the Ca2+ -induced conformational change. In this model the N-terminal region of TnI is bound strongly to the C-terminal domain of TnC in the presence or absence of Ca2+. The inhibitory and C-terminal regions of TnI bind to actin-tropomyosin in the absence of Ca2+ and to tne N- and C-terminal domains of TnC in the presence of Ca2+.
12

Filamentos elásticos de elastolefina de alta durabilidad obtenidos a partir de copolímeros de bloque de etileno-octeno de baja densidad mediante la tecnología de polimerización por transferencia de cadena para aplicaciones en indumentaria de uso profesional

Verdú Blasco, Pau 29 October 2010 (has links)
En la actualidad el mercado carece de prendas elásticas para uso profesional puesto que los elastanos habitualmente utilizados son inestables frente a altas temperaturas y químicos agresivos, e.g. termofijado, mantenimiento de indumentaria industrial etc. Recientemente se han venido utilizado filamentos olefínicos obtenidos a partir de copolímeros al azar de etileno-octeno (Dow XLA fibers producidos por The Dow Chemical Company). Aunque más resistentes a las temperaturas debido a la reticulación, su bajo punto de fusión, alrededor de 50ºC, limita el comportamiento elástico en tejidos pesados y tupidos para indumentaria profesional. La investigación tiene por objeto la obtención de monofilamentos elásticos a partir copolímeros de bloque de etileno-octeno (cuyo punto de fusión es más elevado) y con éstos, tejidos para indumentaria profesional que ofrezcan mayor fuerza de encogimiento a las temperaturas típicas de los pre-tratamientos, tintura y acabado (50ºC-120ºC). El objetivo es hacer que los tejidos encojan más durante las operaciones en húmedo bajo temperatura para mejorar así su elasticidad y aumentar el peso en comparación con los tejidos actuales manufacturados con los convencionales copolímeros homogéneos de etileno-octeno reticulados Los tejidos deberán garantizar las siguientes propiedades durante todo su ciclo de vida: estabilidad dimensional, relación elasticidad-crecimiento mejorado, resistencia química, resistencia térmica, durabilidad ante los lavados industriales y un mejor confort termofisiológico y sensorial. / Due to the lack of stability of elastane based materials against high temperatures and harsh chemicals, e.g. thermofixation and professional wear maintenance, elastic garments with elastane content are not yet fully commercial products. The Dow Chemical Company has recently commercialized a random ethylene-octene copolymer based fiber named Dow XLA fiber. Despite its higher temperature resistance as one of the crosslinking effects, its very low melting point, around 50ºC, establishes some limitations in elasticity such in heavy weight and high densely woven fabric cases typically found in professional wear applications. The target for the investigation is to produce block ethyleneoctene copolymer based filaments in which the melting point is supposed to be higher than in random copolymer materials. Different workwear fabrics will be manufactured with yarns containing such elastic filaments. It is supposed these fabrics to show high shrinkage forces even at dyeing and finishing temperatures, (50ºC-120ºC). The goal is to produce fabrics with superior shrinkage performance in order to achieve an excellent elastic power and the final desired fabric weight. Properties such as dimensional stability, stretch and growth ratio, temperature and chemical resistance and durability against industrial laundering should not be affected by the passage of the time. To validate this point these properties will be measured in the fabrics off loom and after the garment cycle life. These fabrics are also supposed to show better thermophysiological and sensorial properties than random copolymer fiber based textiles
13

Tubula??es de PRFV com adi??o de areia quartzosa visando sua aplica??o na ind?stria do petr?leo

Barros, Gustavo de Ara?jo 19 January 2007 (has links)
Made available in DSpace on 2014-12-17T14:58:25Z (GMT). No. of bitstreams: 1 GustavoAB.pdf: 2461248 bytes, checksum: 0536be02b6961005820ca67a7e2765de (MD5) Previous issue date: 2007-01-19 / Fillers are often added in composites to enhance performance and/or to reduce cost. Fiberglass pipes must meet performance requirements and industrial sand is frequently added for the pipe to be cost competitive. The sand is added to increase pipe wall thickness, thus increase pipe stiffness. The main goal of the present work is to conduct an experimental investigation between pipes fabricated with and without de addition of sand, to be used in the petroleum industry. Pipes were built using E-glass fibers, polyester resin and siliceous sand. The fabrication process used hand lay up and filament winding and was divided in two different parts: the liner and the structural wall. All tested pipes had the same liner, but different structural wall composition, which is the layer where siliceous sand may be added or not. The comparative investigation was developed considering the results of longitudinal tensile tests, hoop tensile tests, hydrostatic pressure leak tests and parallel-plate loading stiffness tests. SEM was used to analyze if the sand caused any damage to the glass fibers, during the fabrication process, because of the fiber-sand contact. The procedure was also used to verify the composite conditions after the hydrostatic pressure leak test. The results proved that the addition of siliceous sand reduced the leak pressure in about 17 %. In the other hand, this loss in pressure was compensated by a stiffness increment of more than 380 %. MEV analyses show that it is possible to find damage on the fiber-sand contact, but on a very small amount. On most cases, the contact occurs without damage evidences. In summary, the addition of sand filler represented a 27.8 % of cost reduction, when compared to a pipe designed with glass fiber and resin only. This cost reduction combined to the good mechanical tests results make siliceous sand filler suitable for fiberglass pressure pipes / Cargas de adi??o s?o utilizadas com freq??ncia, em materiais comp?sitos, para atingir propriedades mec?nicas requeridas por normas e para redu??o de custos. As tubula??es em pl?stico refor?ado com fibras de vidro (PRFV), utilizadas para aplica??es com altas press?es, devem atender a requisitos m?nimos de projeto estabelecidos em normas. Para tanto, a areia vem sendo utilizada como carga de adi??o, no sentido de manter os tubos em PRFV competitivos no mercado. A areia ? adicionada para aumentar a espessura da parede, aumentando com isso a rigidez. Este trabalho teve como principal objetivo analisar a influ?ncia da areia nas propriedades mec?nicas de tubula??es de PRFV, visando sua aplica??o na ind?stria do petr?leo e do g?s, atrav?s de ensaios comparativos entre tubos com e sem a adi??o de areia. Os tubos foram fabricados com fibras de vidro tipo E na forma de fios cont?nuos e manta, resina poli?ster ortoft?lica e areia quartzosa. A fabrica??o foi realizada em duas etapas distintas, sendo a primeira camada do tubo denominada de barreira qu?mica (processo de lamina??o manual) e a segunda camada denominada estrutura (fabricada pelo processo de filamento cont?nuo). A areia ? adicionada no tubo juntamente com as camadas de filamento cont?nuo e, portanto, ? um constituinte da estrutura do tubo. A an?lise comparativa foi conduzida atrav?s de ensaios de tra??o axial e ircunferencial, press?o hidrost?tica e rigidez, al?m de an?lises com microsc?pio eletr?nico de varredura (MEV). Foram avaliadas as for?as resultantes de ruptura e o m?dulo de elasticidade circunferencial, al?m da rigidez. As an?lises com MEV foram conduzidas para verificar a presen?a de danos causados as fibras, durante o processo de fabrica??o, e para verificar as condi??es do laminado ap?s os ensaios de press?o hidrost?tica. Os resultados mostraram que a adi??o de areia causou uma redu??o na press?o de ruptura do tubo de 17 %. Por?m esta perda foi compensada pelo grande acr?scimo na rigidez que foi da ordem de 380 % . As an?lises no MEV mostraram que ocorrem danos durante o processo de fabrica??o, mas em quantidades muito pequenas. Na maioria dos casos o contato areia/fibras ocorre sem evid?ncias de danos. Em resumo, a areia representa uma redu??o de 27,8 % no custo final do tubo, que somado aos bons resultados obtidos nos ensaios mec?nicos, faz deste material uma excelente op??o de carga de adi??o para tubula??es de PRFV utilizadas com altas press?es
14

Construção de um espectrômetro de absorção atômica e estudos de formação e evolução da nuvem atômica com atomização eletrotérmica em sistema de duplo filamento de tungstênio / Construction of an atomic absorption spectrometer and studies on the formation and evolution of the atomic cloud with electrothermal atomization in a double tungsten coil system

Jora, Manassés Zuliani, 1987- 25 August 2018 (has links)
Orientadores: Celio Pasquini, Joaquim de Araújo Nóbrega / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-25T12:04:34Z (GMT). No. of bitstreams: 1 Jora_ManassesZuliani_M.pdf: 4929889 bytes, checksum: f8da5d6a35fbac5ae2d05d997971561a (MD5) Previous issue date: 2013 / Resumo: A espectrometria de absorção atômica com atomização eletrotérmica (ET AAS) é adequada para a determinação de metais e semimetais, apresentando alta sensibilidade. Dentre os atomizadores eletrotérmicos, os fornos de grafite destacam-se por sua boa seletividade, exigência de pequenos volumes de amostra e baixos limites de detecção (i.e. 'mu'g L-1). Porém, esses atomizadores requerem fontes de alta potência (i.e. superiores a 2 kW), sistema de resfriamento e, ainda, apresentam alto custo. Como alternativa, o uso de superfícies metálicas têm sido objeto de pesquisa desde 1970. Dentre todos os metais empregados na fabricação de superfícies metálicas e utilizados para os estudos em ET AAS, o tungstênio é o que vem apresentando maior aplicação. Porém, a espectrometria de absorção atômica baseada em atomizadores de filamento de tungstênio (WC AAS) apresenta vários desafios relacionados ao entendimento da geração da nuvem atômica e dos efeitos de interferência observados. Dessa maneira, neste trabalho construiu-se um espectrômetro de absorção atômica com duplo filamento de tungstênio (DWC AAS), com duas configurações, uma empregando como sistema de detecção um sistema echelle/detector de carga acoplada intensificado (ICCD) e outra um sistema filtro óptico-acústico sintonizável (AOTF)/fotomultiplicadora. Essas duas configurações do equipamento foram empregadas em estudos de formação e evolução da nuvem atômica de elementos com características voláteis e refratárias (i.e. Pb e Cr). Além disso, estudou-se o efeito de Na, K, Ca e Mg, em três diferentes concentrações (i.e. 1, 10 e 100 mg L-1) sobre os perfis das nuvens atômicas de Pb e Cr. Esse estudo foi conduzido de tal forma que interferências em fase condensada e gasosa puderam ser avaliadas. Além disso, o equipamento foi empregado em medidas de temperatura na superfície do filamento e na fase gasosa / Abstract: Electrothermal atomic absorption spectrometry (ET AAS) is suitable for determination of metals and semimetals with high sensitivity. Among the existing electrothermal atomizers, graphite furnace stands out due to its selectivity, requirement of low volume of sample and low limits of detection (i.e. 'mu'g L-1). Notwithstanding, these atomizers present high cost and requires high power power supply (i.e. above 2 kW) and a cooling system. Alternatively, metallic surfaces have been studied since 1970. Among all metals employed as atomizers in ET AAS studies, tungsten has presented the best results and has found many analytical applications. However, tungsten coil atomic absorption spectrometry (WC AAS) presents several challenges related to understanding the atomic cloud generation and interferences effects. Thus, in this work, a double tungsten coil atomic absorption spectrometer (DWC AAS), with two different configurations was constructed. In one configuration, a detection system based on echelle/intensified charge-coupled device (ICCD) is employed and, in the other, an acousto-optic tunable filter (AOTF)/photomultiplier detection system is used. Both configurations were employed in the atomic cloud generation and evolution studies of Pb and Cr. Furthermore, interferences on the atomic cloud profile of Pb and Cr caused by Na, K, Ca and Mg, at three different concentrations (i.e. 1, 10 and 100 mg L-1), were studied. This study helped to evaluate the effect of condensed and gas phase interferences. Additionally, the equipment was employed to perform measures of surface and gas phase temperatures / Mestrado / Quimica Analitica / Mestre em Química
15

Funções estruturais e regulatórias das regiões N- e C-terminal da troponina I / Structural and Regulatory Functions of the NH2- and COOH-terminal Regions of Skeletal Muscle Troponin I

Chuck Shaker Farah 13 June 1994 (has links)
O complexo troponina-tropomiosina regula a contração muscular esquelética e cardíaca. A ligação do cálcio nos sítios regulatórios localizados no domínio N-terminal da troponina C (TnC) induz uma mudança conformacional que remove a ação inibitória da troponina I (TnI) e inicia a contração muscular. Nós usamos fragmentos recombinantes da TnI e uma série de mutantes da TnC para estudar as interações estruturais e regulatórias das diferentes regiões da TnI com os domínios da TnC, TnT e actina-tropomiosina. Nossos resultados indicam que a TnI é organizada em regiões que apresentam funções estruturais e regulatórias e que se ligam de modo antiparalelo com os correspondentes domínios estruturais e regulatórios da TnC. Estudos funcionais mostram que a região inibitória (aminoácidos 103-116) em combinação com a região C-terminal da TnI (TnI103-182) pode regular a atividade ATPásica da acto-miosina de maneira dependente de Ca2+. A regulação não é observada com a região inibitória em combinação com a região N-terminal (TnI116) Estudos de ligação mostram que a região N-terminal da TnI (TnI1-98) interage com o domínio C-terminal da TnC na presença e na ausência de Ca2+ e também interage com a TnT. A região inibitória/C-terminal da TnI (TnI103-182) interage com o domínio N-terminal da TnC de maneira dependente de Ca2+. Baseados nestes resultados, propomos um modelo para a mudança conformacional induzida pelo Ca2+. Neste modelo, a região N-terminal da TnI está ligada fortemente com o domínio C-terminal da TnC na presença ou na ausência de Ca2+. As regiões inibitórias e C-terminal da TnI ligam-se à actina-tropomiosina na ausência de Ca2+ e nos domínios N-terminal e C-terminal da TnC na presença de Ca2+. / The troponin-tropomyosin complex regulates skeletal and cardiac muscle contraction. Calcium binding to the regulatory sites in the N-terminal domain of troponin C (TnC). induces a conformational change which removes the inhibitory action of troponin I (TnI) and initiates muscular contraction. We used recombinant TnI fragments and a series of TnC mutants to study the structural and regulatory interactions between different TnI regions and the domains of TnC, TnT and actin-tropomyosin. Our results indicate that TnI is organized into regions with distinct structural and regulatory functions which bind, in an antiparallel manner, with the corresponding structural and regulatory domains of TnC. Functional studies show that a fragment containing the inhibitory and C-terminal regions of TnI (TnIl03-182) can regulate the actomyosin ATPase in a Ca2+- dependent manner. Regulation was not observed with a fragment containing the N-terminal and inhibitory regions (TnIl-116). Binding studies show that the N-terminal region of TnI (TnI1-98) interacts with the C-terminal domain of TnC in the presence of Ca2+ or Mg2+. The inhibitory/C-terminal region of TnI (TnI103-182) binds to the N-terminal domain of TnC in a Ca2+-dependent manner. Based on these results, we propose a model for the Ca2+ -induced conformational change. In this model the N-terminal region of TnI is bound strongly to the C-terminal domain of TnC in the presence or absence of Ca2+. The inhibitory and C-terminal regions of TnI bind to actin-tropomyosin in the absence of Ca2+ and to tne N- and C-terminal domains of TnC in the presence of Ca2+.
16

Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in waters

Antonio, Rosana Fernandes 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
17

Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in waters

Rosana Fernandes Antonio 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
18

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens / Development of analytical methods employing optical emission spectrometry to evaluate the level of elemental contaminants in samples of different origins

Gonçalves, Daniel Araujo [UNESP] 08 July 2016 (has links)
Submitted by Daniel Araujo Gonçalves null (daniel.araujogoncalves@gmail.com) on 2016-08-01T13:43:54Z No. of bitstreams: 1 Goncalves_Tese_versão_final.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-02T19:00:04Z (GMT) No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) / Made available in DSpace on 2016-08-02T19:00:04Z (GMT). No. of bitstreams: 1 goncalves_da_dr_ilha.pdf: 3648542 bytes, checksum: 7acd793a874f48c8a008a28e1e550948 (MD5) Previous issue date: 2016-07-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, energético, cerveja, whiskey e cachaça. Não foi necessária preparação da amostra, a não ser uma simples diluição em HNO3 1% v v-1. A eficiência do SDA foi avaliada por experimentos de adição e recuperação e os resultados foram comparados com os métodos tradicionais de calibração externa (EC), o padrão interno (IS) e adição de padrão (AS). As recuperações médias por SDA para vários elementos avaliadas neste trabalho foram entre 90 e 99%. Para o método tradicional de adições padrão, por exemplo, as recuperações médias entre 101 e 122% foram obtidos para os mesmos analitos e amostras. No quarto estudo um MIP OES (MP-AES, Agilent 4200) foi utilizado para a determinação de Cd, Cr, Cu, Ni e Pb na matriz de óleo fusel onde emprega-se a calibração externa preparada em solução de 1% HNO3 e 1-propanol. Soluções contendo 5 e 50% da matriz v v-1 foram diluidas em 1-propanol e solução de óleo fúsel puro foram analisados. Não foram observados efeitos de matriz quando empregou-se a calibração com soluções de 1-propanol mesmo para determinações na amostra não diluída, com recuperações entre 90-109%. Os LODs para Cd, Cr, Cu, Ni e Pb em 1-propanol foram de 0,03; 0,009; 0,01; 0,007 e 0,04 mg L-1, respectivamente. O procedimento descrito para o MIP OES é uma abordagem simples, exata e precisa para rastrear análise de elementos de óleo fúsel. / In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample preparation except a simple dilution in HNO3 1% v v-1 . The efficiency of the SDA was evaluated by experiments of addition and recovery, and the results were compared with the traditional methods of external calibration (EC), the internal standard (IS) and addition of default (AS). Average recoveries for SDA to various elements evaluated in this study were between 90 and 99%. For the traditional method of standard additions, for example, the average recoveries between 101 and 122% were obtained for the same analytes and samples. In the fourth study a MIP OES (MP-AES, Agilent 4200), was used for the determination of Cd, Cr, Cu, Ni e Pb in the array of fusel oil where is used the external calibration solution prepared 1% HNO3 and1-propanol. Solutions containing 5 and 50% of the matrix v v-1 were dissolved in 1-propanol and fusel oil pure solution were analyzed. Matrix effects were not observed when it was calibration with 1-propanol solutions even for undiluted sample determinations, with recoveries between 90 - 109%. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol were of 0,03; 0,009; 0,01; 0,007 and 0,04 mg L-1 , respectively. The procedure described for MIP OES is a simple, accurate and precise approach to trace elements analysis of fusel oil. / CAPES PDSE: 99999.002566/ 2014-01
19

Desenvolvimento de métodos analíticos empregando à espectrometria de emissão óptica para avaliação dos níveis de contaminantes elementares em amostras de diversas origens /

Gonçalves, Daniel Araujo. January 2016 (has links)
Orientador: Mirian Cristina dos Santos / Resumo: Neste trabalho foram desenvolvidos quatro métodos analíticos visando a determinação de elementos químicos em diversas amostras. O primeiro estudo consistiu na determinação de Cr e Mn em placentônios provenientes de bovinos por espectrometria de emissão atômica em filamento de tungstênio (WC AES). O tempo de integração de sinal para 30 ms, proporcionou LOD 45 vezes menor para Mn e 150 vezes menor para Cr com relação a 500 ms. Testes de adição e recuperação apresentaram desvio padrão (SD) de ± 0,02 mg L-1 e recuperações de 91 a 102%. No segundo foram realizadas quantificações de Cr em cápsulas medicinais produzidas na China, a WC AES. A faixa linear de trabalho para determinação de Cr por WC AES foi de 10-100 μg L-1. Os limites de detecção foram de 3 μg L-1, o que possibilitou determinações em um nível 28 vezes menor que o valor máximo de Cr recomendado em medicamentos pela Farmacopeia Americana (USP). A precisão (% RSD) foi calculada na faixa de 5,2 – 7,4% e não foram significativamente diferentes através da aplicação de um teste ANOVA fator único a nível de confiança de 95% (p > 0,05) quando comparados com a técnica de Espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). No terceiro estudo, um Espectrometro de Emissão Óptica com plasma induzido por micro-ondas – MIP OES (MP-AES, Agilent 4200), foi usado em combinação com o método de análise por diluição de padrão (SDA) para determinar Al, Cr, Co, Cu, Fe, Mn, Ni e Zn em amostras de café, chá verde, ene... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work were developed four analytical methods for the determination of chemical elements in several samples. The first study consisted in determination of Cr and Mn in placenton from bovine animals by Atomic emission spectrometry in tungsten filament (WC AES). Signal integration time for 30 ms, provided LOD 45 times lower for Mn and 150 times lower for Cr with respect to 500 ms. Addition and recovery tests presented standard deviation (SD) of ± 0,02 mg L-1 and recoveries of 91 to 102%. In the second were carried out baseline measurements of Cr in medicinal capsule produced in China by WC AES. The linear range for determination of Cr by WC AES was 10 - 100 μg L-1 . The limits of detection were 3 μg L-1 , which allowed determinations in a level 28 times smaller than the maximum value of Cr recommended medicines for the U.S. Pharmacopeial Convention (USP). The precision (% RSD) was estimated in the range of 5,2 – 7,4% and were not significantly different by applying a test ANOVA single factor at the level of confidence 95% (p > 0,05) when compared with Optical emission spectrometry with inductively coupled plasma (ICP OES). In the third study, a Spectrometer of Optical Emission plasma induced by microwave – MIP OES (MP-AES, Agilent 4200), was used in combination with the method of analysis for standard dilution (SDA) to determine Al, Cr, Co, Cu, Fe, Mn, Ni e Zn in samples of coffee, green tea, energetic, beer, whiskey and cachaça brazilian. It didn't require sample prepara... (Complete abstract click electronic access below) / Doutor
20

Caracterização Funcional e Determinação da Estrutura Tridimensional por Cristalografia de Raios X da Proteína RecA de Herbaspirillum seropedicae

Leite, Wellington Claiton 06 September 2016 (has links)
Made available in DSpace on 2017-07-21T19:25:54Z (GMT). No. of bitstreams: 1 Wellington Claiton Leite.pdf: 3789073 bytes, checksum: f4c16b4260fbd54f4eada652038ae5bc (MD5) Previous issue date: 2016-09-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The bacterial RecA protein plays a role in the complex system of DNA damage repair. In the presence of ATP, RecA proteins polymerize onto single-strand DNA (ssDNA) as righthanded helical nucleoprotein laments, and catalyze strand exchange reaction between the ssDNA and homologous double-strand DNA (dsDNA) molecules. These activities are supported or stimulated by accessory proteins, as the single-stranded binding protein (SSB).Here, we report a functional and structural characterization of the Herbaspirillum seropedicae RecA protein (HsRecA).We report the crystal structure of HsRecA-ADP/ATP complex to 1.7 Å of atomic resolution. HsRecA protein contains a small N-terminal domain, a central core ATPase domain and a large C-terminal domain, similarly to homologous RecA proteins. Comparative structural analysis showed that the N-terminal polymerization motif of archaeal and eukaryotic RecA family proteins are also present in bacterial RecAs. The bacterial polymerization motif contains the sequence SV/IMR/KLG which interacts with the core ATPase domain residues DNLLLV/CS. In the inactive RecA, it is a loop - strand interaction, respectively, while in the active RecA it becomes a dyad strand. In both RecA forms, the polymerization motif seems to stabilize the subunitsubunit interface by hydrophobic interactions. The methionine of this motif may play an important role in the stability and formation of a right-handed helical nucleoprotein lament. The ATPase activity and the structure of the nucleoprotein lament of HsRecA and Escherichia coli RecA (EcRecA) were analyzed in the presence and absence of SSB. When SSB was added after RecA+ssDNA, HsRecA and EcRecA showed similar ATPase activity and nucleolament structure. However, when SSB was either not included or it was added before RecA+ssDNA, the HsRecA showed higher ATPase activity and formed longer nucleoprotein laments than EcRecA. Thus, HsRecA protein is more ecient at displacing SSB from ssDNA than EcRecA protein. HsRecA promoted DNA exchange more eficiently: a greater yield of nicked circular products were obtained in a shorter time. Reconstruction of electrostatic potential from the hexameric structure of HsRecAADP/ ATP revealed a high positive charge along the inner side, which is consistent with the fact that ssDNA binds inside the filament. It may explain the enhance capacity of HsRecA protein to bind ssDNA, forming a contiguous nucleoprotein filament, displace SSB and promote eficiently the DNA strand exchange reaction. Keywords: RecA, Crystallography, RecA nucleoprotein filament, ATPase activity, DNA strand exchange, crystal structure, structural analysis. / A proteína RecA bacteriana desempenha um importante papel no complexo sistema de reparo de danos ao DNA. Na presença de ATP, a proteína RecA se auto-polimeriza sobre o DNA simples ta (ssDNA) (do inglês single-strand DNA (ssDNA)) como um lamento de nucleoproteína helicoidal, cataliza a reação de troca de fitas entre as moléculas ssDNA e a ta de DNA dupla fita homóloga (dsDNA) (do inglês double-strand DNA (dsDNA)). Estas atividades são suportadas ou estimuladas por proteínas acessórias, como a proteína ligadora de ssDNA SSB (do inglês single-stranded binding protein (SSB)). Neste trabalho é apresentado a caracterização estrutural e funcional da proteína RecA da bactéria Herbaspirillum seropedicae. A estrutura tridimensional do complexo HsRecA-ADP/ATP foi resolvida numa resolução 1,7 Å. A estrutura monomérica da proteína HsRecA consiste em um pequeno domínio N-terminal, um domínio central contendo um sitío ATPásico e e um grande domínio C-terminal, similar com proteínas RecAs homólogas. Análises estruturais comparativas mostraram que o motivo de polimerização da região N-terminal de proteí- nas da familia RecA que incluem archaea e eucariotos, também está presente na proteína RecA bacteriana. O motivo de polimerização da região N-terminal de bactérias contêm a sequência de resíduos (Serina, Valina ou Isoleucina, Metionina, Arginina ou Lisina, Leucina, Glicina) que interage com a sequência de resíduos do core ATPásico (Aspartato, Asparagina, Leucina, Leucina, Leucina, Valina, Cisteína, Serina). Na proteína RecA inativa esta interação é do tipo loop - strand, respectivamente, enquanto na proteína RecA ativa essa interação se torna uma dupla -strand. Em ambas formas da RecA, o motivo de polimerização parece estabilizar a interface subunidade-subunidade por interações hidrofóbicas. No motivo N-terminal a presença de uma Metionina altamente conservada talvez desempenha um importante papel na estabilidade e formação do lamento de nucleoproteína. A atividade ATPásica e a estrutura do lamento de nucleoproteína da proteína HsRecA e da Escherichia coli RecA (EcRecA) foram analisadas na presença e ausência da proteína SSB. Quando a SSB foi adicionada após RecA+ssDNA, as proteínas HsRecA e EcRecA mostraram similar atividade ATPásica e estrutura de nucleo lamento. Entretanto, quando a SSB não estava incluída ou quando adicionada anteriormente a adição RecA+ssDNA, a proteína HsRecA mostrou maior atividade ATPásica e formou maiores lamentos de nucleoproteína que a proteína EcRecA. Ainda, a proteína HsRecA é mais eficiente em deslocar a SSB do ssDNA que a proteína EcRecA. A proteína HsRecA também promove a reação de troca de fitas mais eficientemente: uma maior quantidade de produtos duplex substrato convertido em duplex circular foram obtidos em um curto intervalo de tempo. A reconstrução do potencial eletrostático da estrutura hexamérica da proteína HsRecA revelou uma maior densidade de cargas positivas no seu interior, que é consistente com o fato que o ssDNA ligar-se internamente ao filamento hexamérico. Isto talvez possa explicar capacidade melhorada da proteína HsRecA ligar-se ao ssDNA, formando um continuo filamento de nucleoproteína, deslocando a SSB e ainda promovendo de forma eficiente a reação de trocas de fitas.

Page generated in 0.0748 seconds