Deflections of reinforced concrete flat slabsEigelaar, Estee M. 03 1900 (has links)
Thesis (MScEng (Civil Engineering))--University of Stellenbosch, 2010. / ENGLISH SUMMARY: It is found that the serviceability limit state often governs the design of slender reinforced concrete
members. Slender flexural members often have a percentage tension reinforcement less than 1.0%
and an applied bending moment just above the point of first cracking. For such members, the
available methods to evaluate the serviceability conditions produce inadequate and unrealistic
results. The evaluation of the serviceability of a slender member includes the calculation of the
predicted deflection, either by empirical hand-calculation or analysing a finite element model, and
the verification using the span-to-effective-depth ratio.
The focus of the study is on flat slab structures. It investigates the different deflection prediction
methods and the span-to-effective-depth ratio verifications from various design standards. These
design standards include the ACI 318 (2002), the SABS 0100-1 (2000), the EC2 (2004) and the BS
8110 (1997). The background to the methods, as well as the parameters which influences the
deflection development for lightly reinforced members, are investigated in order to define the
limitations of the methods. As a result of the investigation of the deflection calculation methods, an
Alternative Approach is suggested and included in the comparisons of the various methods.
The deflection prediction methods and the span/effective depth verification procedures are
accurately formulated to predict the serviceability behaviour of beams. Additional approaches had
to be used to apply these methods to a two-dimensional plane such as that of a flat slab structure.
The different deflection prediction methods and the span/effective depth verification methods are
calculated and compared to the recorded data of seven experimental flat slab specimens as
performed by others. A study by Gilbert and Guo (2005) accurately recorded the flexural behaviour
of flat slab specimens under uniformly distributed loads for test periods up to 750 days. The
methods to evaluate the serviceability of a slender member were also applied to slab examples
designed using South African standards.
The study concludes by suggesting a suitable deflection prediction method for different parameter
(limitation) categories with which a slender member can comply to. The typical span/effective depth
ratio trend is also presented as the percentage tension reinforcement for a slender member changes. It is observed that the empirical hand-calculation methods present more reliable results
than those of the finite element models. The empirical hand-calculation methods are accurate
depending on the precision to which the slab was constructed relative to the actual slab design.
The comparison of the deflection methods with South African case studies identified the role played
by construction procedures, material parameters and loading history on slab behaviour. / AFRIKAANSE OPSOMMING: Die diensbaarheidstoestand is in baie gevalle die bepalende faktor vir die ontwerp van slank
gewapende beton elemente bepaal. Slank elemente, soos lig bewapende buigbare beton elemente,
het gewoonlik ‘n persentasie trekbewapening van minder as 1.0% en ‘n aangewende buigmoment
net wat net groter is as die punt waar kraking voorkom. Die metodes beskikbaar om die
diensbaarheid van sulke elemente te evalueer gee onvoldoende en onrealistiese resultate. Die
evaluering van die elemente in die diensbaarheidstoestand sluit in die bepaling van defleksies deur
berekening of die analise van ‘n eindige element model, en die gebruik van die span/effektiewe
diepte metode.
Die fokus van die studie is platbladstrukture. Die doel van die studie is om die verskillende metodes
vir die bereking van defleksie asook die verifikasie volgens span/effektiewe diepte metodes van die
verskillende ontwerp standaarde te ondersoek. Die ontwerp standaarde sluit die ACI 318 (2002),
SABS 0100-1 (2000), EC2 (2004) en die BS 8110 (1997) in. Die agtergrond van hierdie metodes is
ondersoek asook die parameters wat ‘n rol speel, sodat die beperkings van die metodes
geidentifiseer kan word. As ‘n gevolg van die ondersoek na die beperkings van die metodes, is ‘n
Alternatiewe Benadering voorgestel. Die Alternatiewe Benadering is saam met die metodes van die
ontwerpstandaarde gebruik om die verskille tussen die metodes te evalueer.
Die defleksievoorspelling en die span/effektiewe diepte verifikasie metodes is korrek geformuleer
om die diensbaarheid van balke te evalueer. Ander benaderings was nodig om die diensbaarheid van
blad blaaie te toets.
Die onderskeie defleksievoorspelling en span/effektiewe diepte metodes is bereken vir sewe
eksperimentele plat blaaie soos uitgevoer deur ander navorsers. Gilbert and Guo (2005) het ‘n studie
uitgevoer waar die buigingsgedrag van die sewe plat blaaie, met ‘n uniforme verspreide las vir ‘n
toetsperiode van tot 750 dae, akkuraat genoteer is. Die metodes om die diensbaarheid van ‘n slank
element te toets, was ook op Suid-Afrikaanse blad voorbeelde getoets. Dit was gedoen om die Suid-
Afrikaanse ontwerp van ligte bewapende beton elemente te evalueer. Die gevolgetrekkings stel ‘n gepaste defleksie metode vir ‘n slank element vir verskillende beperking
kategorië voor. Dit is ook verduidelik hoe die tipiese span/effektiewe diepte verhouding met die
persentasie trek bewapening vir ‘n slank element verander. Dit is bevind dat die imperiese
handmetodes om defleksies te bereken, meer betroubaar as die eindige element modelle se
resultate is. Die imperiese handberekening metodes is akkuraat relatief tot hoe akkuraat die blad
konstruksie tot die blad ontwerp voltooi is.
‘n Vergelyking van defleksieberekening met Suid-Afrikaanse gevallestudies het die belangrikheid van
konstruksieprosedures, materiallparamteres and belastingsgeskiedenis geïdentifiseer.
|
12 |
Punção em lajes lisas de concreto armado com furo adjacente ao pilar e transferência de momento / Punching Shear In Reinforced Flat Slabs with Hole Adjacent to the Column and Moment TransferOLIVEIRA, Diorgenes Carvalho de 17 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:03:34Z (GMT). No. of bitstreams: 1
Dissertacao Diorgenes C de Oliveira.pdf: 4985818 bytes, checksum: 3bb65a23267322ba684300f2b7486ab1 (MD5)
Previous issue date: 2011-06-17 / The structural behavior and the ultimate punching shear resistance of internal reinforced concrete flat slab-column connections, with one hole adjacent to the column, with or without flexural moment transfer of the slab to the column was investigated. Main variables were: the existence whether or not hole, flexural reinforcement layout and ratio, the direction and sense of the moment transferred and the eccentricity of the load (M (moment transferred to column) / V (shear)) ratio at the connection - 0,50 m or 0,25 m.
Seven internal slab-column joining were tested and ultimate loads, cracking, deflections, concrete and reinforcement strains were analyzed. The existence of hole adjacent to the smaller column dimension, the hole dimension, flexural reinforcement rate and placing, the variation of relation Mu/Vu in function of the load, and, than, of eccentricity of the load, influenced the slabs behavior and rupture load. These influences were quantified.
Test results were compared with the estimations from CEB-FIP/MC1990, EC2/2004, ACI-318:2005 and NBR 6118:2003. ACI and EC2 presented most conservative estimates, although have presented some non conservative estimates. Brazilian NBR, even though being partly based in EC2, presented smaller conservative estimates and more non conservative estimates. A modification on all codes is proposed for taking in account the moment caused by the eccentricity at the critical perimeter for slabs with holes. / São investigados o comportamento estrutural e a resistência última à punção de ligações laje-pilar de regiões internas das lajes lisas, com um furo adjacente ao pilar, e com ou sem transferência de momento fletor da laje ao pilar. As principais variáveis foram: a existência ou não de furo, a taxa e a distribuição da armadura de flexão, a direção e o sentido do momento transferido e a excentricidade de carga (relação M(momento transferido ao pilar)/V(força cortante)) na ligação, igual a 0,50 m ou 0,25 m. Foram ensaiadas 7 (sete) ligações internas laje-pilar e analisados os resultados das cargas últimas, fissuração, deslocamento vertical, deformações das armaduras de flexão e do concreto.
A existência de furo adjacente ao menor lado do pilar, a taxa e a distribuição da armadura de flexão, a variação da relação Mu/Vu em função do carregamento, e, por conseguinte, da excentricidade, influenciaram o comportamento e a carga de ruptura das lajes. Essas influências foram quantificadas.
Os resultados experimentais foram comparados com os estimados pelas normas: CEB-FIP/MC1990, EC2/2004, ACI-318:2005 e NBR 6118:2003. O ACI e o EC2 apresentaram estimativas mais conservadoras, embora tenham apresentado algumas estimativas contra a segurança. A NBR 6118:2003, apesar de baseada em parte no EC2, apresentou estimativas menos conservadoras e com um número maior de estimativas contra a segurança. Recomenda-se que todas as normas passem a considerar o momento causado pela excentricidade do perímetro crítico em lajes com furos e, neste sentido, foram apresentadas propostas de modificações para todas as normas estudadas.
|
13 |
Estudio numérico parametrizado del punzonamiento en losas de hormigón armado. Evaluación del refuerzo estructuralNavarro Menargues, Miguel 06 September 2018 (has links)
En el presente trabajo se aborda la tesis “Estudio paramétrico con FEM del refuerzo a punzonamiento de losas de hormigón armado”. Se trata de todo lo relacionado con el fenómeno resistente de punzonamiento en estructuras, especialmente en forjados construidos mediante hormigón armado. Se trata de cuatro apartados bien diferenciados. En este, el primero, se desarrolla la síntesis de la tesis, donde se marcan unos objetivos, seguido de una explicación detallada y descripción de este fenómeno mediante su estado del arte, que abarca el grueso de éste primer apartado, en el cual se describen, entre otros aspectos, las diferentes patologías producidas por el punzonamiento y casos de sucesos catastróficos que provocaron, la historia de los forjados y los principales estudios llevados a cabo sobre este fenómeno, y acabando con las principales resultados y conclusiones de la tesis. Después, el segundo y tercer apartado contienen los artículos publicados y no publicados, respectivamente, por capítulos. Por último, se desarrollan las conclusiones en el último y cuarto apartado.
|
14 |
Punção em lajes-cogumelo de concreto de alta resistência reforçado com fibras de aço / Punching shear in high-strength concrete flat slabs reinforced with steel fibreZambrana Vargas, Elioth Neyl 16 June 1997 (has links)
Neste trabalho investiga-se o comportamento resistente de lajes-cogumelo de concreto armado, analisando-se as possibilidades de melhoria de desempenho com relação ao fenômeno de punção, pelo emprego de concreto de alta resistência, pelo reforço com fibras de aço e pelo uso de armaduras transversais de combate à punção, através de ensaios de modelos de lajes-cogumelo quadradas que representam a ligação laje-pilar para o caso do pilar interno. Apresenta-se também uma revisão de conhecimentos sobre as lajes-cogumelo, o seu comportamento estrutural com ênfase no fenômeno da punção, e os principais conceitos sobre os concretos de alta resistência e os compósitos constituídos de matriz de cimento reforçada com fibras. Doze modelos de laje-cogumelo foram ensaiados com diferentes combinações de concreto de alta resistência, concreto de resistência convencional, armadura transversal e volume de fibras (0%, 0,75% e 1,5%). Um acréscimo significativo de resistência à punção foi observado, devido ao uso de concreto de alta resistência e à adição de fibras. A combinação de concreto de alta resistência com 1,5% de volume de fibras e armadura transversal proporcionaram o dobro de aumento na resistência à punção em relação ao modelo de concreto convencional sem armadura transversal e sem adição de fibras. A adição de fibras é a suposta responsável por cerca de 50% de acréscimo de resistência e o aumento da ductilidade. Outras comparações incluindo as previsões teóricas (Texto Base da NB1/94, CEB/90, AGI 318/89 e EUROCODE N.2) são comentadas. / This work investigates the behavior of reinforced concrete flat slabs, analysing the possibility of performance improvement, in relation to punching shear phenomenon, regarding to the use of high strength concrete, the addition of steel fibres and the use of transversal steel reinforcement against punching shear, through tests of flat slab square models that represent the slab-column connection, for the case of an interior column. lt introduce a revision of knowledge of flat slabs, their structural behavior with emphasis on the punching shear phenomenon, and the main concepts about high strength concretes and the composites made of cement matrix reinforced with fibres. Twelve flat slab models were tested in different combinations of high strength concrete, ordinary strength, shear reinforcement and steel fibre volume fraction (0%, 0,75% e 1,5%). A significant increase in the punching shear strength was observed, either due to the use of high strength and the addition of steel fibres. The combination of high strength concrete with 1,5% fibre volume fraction and shear reinforcement provide twice the punching shear resistance of an ordinary concrete strength model without shear reinforcement and without fibre. Fibre addition is supposed to be responsible by about 50% of the resistance improvement and the increase of ductility. Other comparisons including theoretical previsions (Texto Base da NB1/94, CEB/90, ACI 318/89 e EUROCODE N.2) are commented.
|
15 |
Punção em lajes-cogumelo de concreto de alta resistência reforçado com fibras de aço / Punching shear in high-strength concrete flat slabs reinforced with steel fibreElioth Neyl Zambrana Vargas 16 June 1997 (has links)
Neste trabalho investiga-se o comportamento resistente de lajes-cogumelo de concreto armado, analisando-se as possibilidades de melhoria de desempenho com relação ao fenômeno de punção, pelo emprego de concreto de alta resistência, pelo reforço com fibras de aço e pelo uso de armaduras transversais de combate à punção, através de ensaios de modelos de lajes-cogumelo quadradas que representam a ligação laje-pilar para o caso do pilar interno. Apresenta-se também uma revisão de conhecimentos sobre as lajes-cogumelo, o seu comportamento estrutural com ênfase no fenômeno da punção, e os principais conceitos sobre os concretos de alta resistência e os compósitos constituídos de matriz de cimento reforçada com fibras. Doze modelos de laje-cogumelo foram ensaiados com diferentes combinações de concreto de alta resistência, concreto de resistência convencional, armadura transversal e volume de fibras (0%, 0,75% e 1,5%). Um acréscimo significativo de resistência à punção foi observado, devido ao uso de concreto de alta resistência e à adição de fibras. A combinação de concreto de alta resistência com 1,5% de volume de fibras e armadura transversal proporcionaram o dobro de aumento na resistência à punção em relação ao modelo de concreto convencional sem armadura transversal e sem adição de fibras. A adição de fibras é a suposta responsável por cerca de 50% de acréscimo de resistência e o aumento da ductilidade. Outras comparações incluindo as previsões teóricas (Texto Base da NB1/94, CEB/90, AGI 318/89 e EUROCODE N.2) são comentadas. / This work investigates the behavior of reinforced concrete flat slabs, analysing the possibility of performance improvement, in relation to punching shear phenomenon, regarding to the use of high strength concrete, the addition of steel fibres and the use of transversal steel reinforcement against punching shear, through tests of flat slab square models that represent the slab-column connection, for the case of an interior column. lt introduce a revision of knowledge of flat slabs, their structural behavior with emphasis on the punching shear phenomenon, and the main concepts about high strength concretes and the composites made of cement matrix reinforced with fibres. Twelve flat slab models were tested in different combinations of high strength concrete, ordinary strength, shear reinforcement and steel fibre volume fraction (0%, 0,75% e 1,5%). A significant increase in the punching shear strength was observed, either due to the use of high strength and the addition of steel fibres. The combination of high strength concrete with 1,5% fibre volume fraction and shear reinforcement provide twice the punching shear resistance of an ordinary concrete strength model without shear reinforcement and without fibre. Fibre addition is supposed to be responsible by about 50% of the resistance improvement and the increase of ductility. Other comparisons including theoretical previsions (Texto Base da NB1/94, CEB/90, ACI 318/89 e EUROCODE N.2) are commented.
|
16 |
The effect of pre-stressing location on punching shear capacity of concrete flat slabsVosoughian, Saeed January 2019 (has links)
Implementing pre-stressing cables is a viable option aiming at controlling deformation and cracking of concrete flat slabs in serviceability limit state. The pre-stressing cables also contribute to punching shear capacity of the slab when they are located in vicinity of the column. The positive influence of pre-stressing cables on punching capacity of the concrete slabs is mainly due to the vertical component of inclined cables, compressive in-plane stresses and counter acting bending moments near the support region. The method presented in Eurocode 2 to determine the punching capacity of the pre-stressed concrete flat slabs considers the in-plane compressive stresses but totally neglects the effect of counter acting moments. The effect of vertical forces introduced by inclined cables is only considered when they are within the distance 2d from the face of the column. This area is called basic control area in the Eurocode 2. In this master thesis nonlinear finite element analysis is carried out to study the effect of pre-stressing cables on punching shear capacity of concrete slabs respecting the distance of cables from the face of the column. To attain this objective, the concrete damage plasticity model is implemented to model the concrete. The results indicate that until the distance of 6d from the face of the column the contribution of pre-stressing cables in punching shear capacity of slabs is significant. Furthermore, comparing the numerical results with the punching shear capacity of slabs predicted by Eurocode 2 reveals that Eurocode tremendously underestimates the punching shear capacity when the cables are located outside the basic control area.
|
17 |
Estabilidade em edifícios de concreto armado com pavimentos em lajes planas.Cicolin, Luiz Antonio Betin 24 August 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:08Z (GMT). No. of bitstreams: 1
1616.pdf: 4035803 bytes, checksum: 02081aa2752efe82918a70652eda7c2e (MD5)
Previous issue date: 2007-08-24 / This present work covers possible manners of evaluating steel concrete frames designed for
multiple flooring buildings as far as instability and necessity of second order efforts are
concerned. Starting from single floor projects with simple flat slab frame, models with
different numbers of floors are considered. The models do not use large rigidity elements
such as staircases and lift shafts. The modeling used in this piece adopts simplified criteria
for vertical action dimensioning, forming frames with flat slab layers taken as low height
beams. These models are evaluated. Based on the results, the work analyzes the
application validity of criteria to dismiss consideration of the NBR6118:2003 code
presented second order global effort, and compares this against the P-∆ process utilization.
Results both with and without inverted beams at the periphery are compared. / O presente trabalho aborda maneiras possíveis de avaliar estruturas de concreto armado
destinadas a edifícios de múltiplos pavimentos quanto à instabilidade e necessidade de
considerações de esforços de segunda ordem. A partir de plantas simples de estruturas em
lajes planas, são considerados modelos com diferentes números de pavimentos. Os modelos
não utilizam elementos de grande rigidez, como poços de elevadores e escadas. A
modelagem utilizada adota os critérios simplificados para dimensionamento às ações
verticais, formando pórticos com faixas de lajes admitidas como vigas de pequena altura.
Estes modelos são avaliados. A partir dos resultados, analisa- se a validade a aplicação dos
critérios para dispensa de consideração dos esforços globais de segunda ordem
apresentados na NBR6118:2003, e se compara com a utilização do processo P-∆. São
comparados resultados para estruturas com e sem utilização de vigas invertidas na periferia.
|
18 |
Contribuição ao projeto e execução de lajes lisas nervuradas pré-fabricadas com vigotas treliçadasAvilla Junior, Jovair 18 February 2010 (has links)
Made available in DSpace on 2016-06-02T20:09:13Z (GMT). No. of bitstreams: 1
3338.pdf: 4319897 bytes, checksum: 32b80c93c455c298962c6b33fd51002a (MD5)
Previous issue date: 2010-02-18 / The big surge in use of systems for flat slabs gave up the search for freedom in the definition and organization of architectural interior spaces in buildings. The design and construction of buildings on flat slabs, which allow great mobility in defining the internal space of the building and reducing its height. The slabs with prefabricated trussed beams using forms lost in blocks of expanded polystyrene (EPS) or removable forms, brought new perspectives to the design of flat slabs, allowing greater spans with low deadweight. The precast elements are lightweight, easy handling, transport and assembly, and require the use of molds and special equipment and requires little bracing. Computer programs have emerged in recent years provide more refined calculations that predict the behavior of the structure in service with greater precision. This way the designers have increased security in systems design less common as flat slabs ribbed, without internal beams, capitals and even edge beams. In Brazil the predominant culture in the design and implementation of flat slabs is given by the system option molded on site. The objectives of this study are: to seek answers to the prevailing cultural behavior, and to compare their advantages and disadvantages when compared with cast on site, presenting the normative regulations and simplified calculation method according to ABNT NBR 6118:2003, provide subsidies for the project and implementation of flat slabs with ribbed prefabricated trussed beams, provide a calculation method for the infinitely rigid diaphragm; present a real case study as a comparison of costs. / O grande impulso na utilização dos sistemas de lajes lisas deu-se pela busca de liberdade na definição e organização arquitetônica de espaços internos em edifícios. O projeto e execução de edificações em lajes lisas, permitem grande mobilidade na definição do espaço interno do edifício e na redução da sua altura final. As lajes pré-fabricadas com vigotas treliçadas que utilizam fôrmas perdidas em blocos de Poliestireno Expandido (EPS) ou fôrmas removíveis trouxeram novas perspectivas ao projeto de lajes lisas, permitindo vãos maiores com baixo peso próprio. Os elementos pré-moldados são leves, de fácil manuseio, transporte e montagem, dispensam o uso de fôrmas e equipamentos especiais e requerem pouco escoramento. Programas computacionais surgidos nos últimos anos propiciam cálculos mais refinados que permitem prever o comportamento em serviço da estrutura com maior precisão. Dessa maneira, os projetistas têm maior segurança no projeto de sistemas menos usuais, como lajes lisas nervuradas, sem vigas internas, capitéis e até mesmo vigas de borda. No Brasil, a cultura predominante no projeto e execução de lajes lisas se dá pela opção do sistema moldado no local. Nestes termos, os objetivos do presente trabalho são: buscar respostas para o comportamento cultural predominante; comparar suas vantagens e desvantagens em relação aos sistemas moldados no local; apresentar as regulamentações normativas e o método de cálculo simplificado segundo a ABNT NBR 6118:2003; fornecer subsídios para o projeto e execução das lajes lisas nervuradas pré-fabricadas com vigotas treliçadas; apresentar um método de cálculo para o diafragma infinitamente rígido e apresentar um estudo de caso real como comparativo de custos.
|
19 |
Comparação experimental entre tipos de armadura de cisalhamento para combate à punção em lajes cogumelo de concreto armado: Stud rails e Double headed studs / Comparison between experimental types of shear reinforcement to combat punch mushroom slabs of concrete, "Stud rails" and "Double headed studs"RODRIGUES, David Rosa 29 September 2009 (has links)
Made available in DSpace on 2014-07-29T15:03:41Z (GMT). No. of bitstreams: 1
David Rosa Rodrigues.pdf: 6647846 bytes, checksum: 0949b9b9e50ce27a724b92ea2943c5d1 (MD5)
Previous issue date: 2009-09-29 / This research presents the results of an experimental comparison between the types of shear reinforcement "stud rails" and "double headed studs" to combat the punching shear of a reinforced concrete flat slabs. It also presents a comparison of experimental results with those provided under the ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 and NBR 6118:2003. The motivation was to investigate the efficiency of these shear reinforcement for the differences between them.
It was tested six slabs of concrete to concentric load, with dimensions of 2400 mm x 2400 mm x 150 mm. It was concreted a column of section 500 mm x 200 mm to 850 mm total height next to the slab. The main variables were the type of shear reinforcement "stud rails" x "double headed studs, the "studs" diameter and the shear reinforcement area per layer. The slabs were tested until the failure.
It was monitored the deflection, reinforcement deformation of bending and shear. All slabs failed by punching with internal surface rupture. The experimental results after being compared with the expected standard in each individual calculation showed conservative values.
Slabs of Group 1 with "stud rails" presented failed loads greater than those in Group 2 with "double headed studs. Codes/standards 318/2005 ACI, CEB-FIP MC/1990, EUROCODE 2 / 2004 and NBR 6118:2003 safely predict the failed loads of all slabs.
The base of the shear reinforcement type "stud rails" moving inside the column may have reduced the failed load of the slab L3.
Shear reinforcement type stud rails it is easer of assembly and play than the type double headed studs . / Esta pesquisa apresenta os resultados de uma comparação experimental entre os tipos de armadura de cisalhamento stud rails e double headed studs para combate à punção em lajes cogumelo de concreto armado. Apresenta, também, uma comparação dos resultados experimentais com os previstos segundo o ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 e a NBR 6118:2003. A motivação foi investigar a eficiência destas armaduras de cisalhamento a procura de diferenças entre elas.
Foram ensaiadas seis lajes maciças de concreto armado à punção centrada, com dimensões 2400 mm x 2400 mm x 150 mm. Foi concretado junto à laje um pilar de seção 500 mm x 200 mm com altura total 850 mm. As principais variáveis foram o tipo de armadura de cisalhamento: stud rails x double headed studs , o diâmetro dos studs e a área de armadura de cisalhamento por camada. As lajes foram ensaiadas até a ruptura.
Foram monitoradas as flechas, deformações da armadura de flexão e cisalhamento. Todas as lajes romperam por punção com superfície de ruptura interna. Os resultados experimentais após serem comparados com os esperados segundo cada norma de cálculo apresentaram valores conservadores.
As lajes do Grupo 1 com stud rails apresentaram cargas de ruptura maiores que as do Grupo 2 com double headed studs . Os códigos/normas ACI 318/2005, CEB-FIP MC/1990, EUROCODE 2/2004 e a NBR 6118:2003 previram com segurança as cargas de ruptura de todas as lajes.
A base da armadura de cisalhamento tipo stud rails avançando dentro do pilar pode ter reduzido a carga de ruptura da Laje L3.
A armadura de cisalhamento tipo stud rails apresenta maior facilidade de montagem e execução que a tipo double headed studs .
|
20 |
Inverkan av placering av spännkablar pågenomstansningskapacitet hos armeradebetongplattor / Influence of Post-Tensioned Reinforcement Distribution on Punching Shear Capacity of RC SlabsTran, David, Correa, Sebastian January 2018 (has links)
På grund av bostadsbristen de senaste åren har byggbranschen varit tvungen att möta den höga efterfrågan på bostäder. Ett sätt att underlätta det tryck som skapats på grund av den höga efterfrågan är att rekonstruera byggnader avsedda för annan användning än bostäder till bostadshus. Ett problem som har uppstått vid ombyggnation av till exempel ett kontorshus som består av spännarmerade pelardäck, är känsligheten för nya hål som krävs för nya installationer som går igenom de efterspända bjälklagen (bestående av betongplattor). Problematiken består av att håltagningar som vanligtvis är lokaliserade nära pelarna måste göras på ett större avstånd från pelaren på grund av de spännkablar som går över och nära plattans pelaranslutning. Efterspända kablar är normalt sett belägna över plattans pelaranslutning enligt dagens dimensioneringsnormer för att bidra till plattornas genomstansningskapacitet.I detta examensarbete undersöktes det om det finns vetenskapligt stöd för att flytta kablarna till en längre distans från pelaren (än vad normerna rekommenderar) med hänsyn till genomstansningskapaciteten, och därmed förenkla vid en potentiell ombyggnation.Huvudsyftet med arbetet var att med hjälp av en litteraturstudie samt beräkningar jämföra ett experiment som utförts av Ghassem Hassanzadeh och Håkan Sundquist vid KTH 1997- 1998 (som visade att kablar på ett längre avstånd från pelaren ger ett visst bidrag till betongplattans genomstansningskapacitet) med dagens normer samt nyare studier. Dagens dimensioneringsnormer inkluderar inte bidraget till kapaciteten när spännkablarna placeras utanför det så kallade grundkontrollsnittet (området som undersöks vid dimensionering enligt normerna).Ett annat syfte med detta examensarbete var att studera och uppdatera de beräknade resultaten (enligt dåtidens normer) från studien. Denna rapport uppdaterar studien genom att undersöka rådande normernas beräknade resultat samt jämföra med liknande tester från andra forskare. Dimensioneringsnormerna som undersöktes var Eurokod 2, ACI 318 och MC2010Som del av litteraturstudien redovisas även en liknande försökserie från Portugal av A. Pinho Ramos, Valter J.G. Lúcio & Duarte M.V Faria samt en sammanställning av olika försök som genomfördes i Schweiz av Clément T, Ramos A.P, Fernández Ruiz M, Muttoni A. Sammanställning i Schweiz beräknade genomstansningskapaciteten för 74 olika plattor där plattorna från försöket vid KTH finns med. Den här studien tyder på att dagens dimensioneringsnormer har en säkerhetsmarginal vid approximationer (vid både normalfall och vid flytt av kablar), men att det fortfarande saknas tillräckliga belägg för att rättfärdiga en flytt av spännkablar.Rapporten är skriven för CBI Betonginstitutet där G. Hassanzadeh har varit handledare.
|