• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 862
  • 15
  • 9
  • 8
  • 8
  • 8
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 888
  • 550
  • 358
  • 160
  • 158
  • 157
  • 155
  • 125
  • 122
  • 114
  • 111
  • 106
  • 100
  • 90
  • 87
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Estudo da filtração de fluidos reticulados em simulações fisicas de fraturamento hidraulico

Grothe, Vinicius Perrud 02 April 2000 (has links)
Orientador: Paulo Roberto Ribeiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-26T01:53:08Z (GMT). No. of bitstreams: 1 Grothe_ViniciusPerrud_M.pdf: 13157053 bytes, checksum: ca5b5de3f1248bcda2acaf689c74a79c (MD5) Previous issue date: 2000 / Resumo: A perda de fluido por filtração é um dos aspectos fundamentais no projeto e na execução de operações de fraturamento hidráulico. Este trabalho teve como objetivos: o estudo da filtração associada à propagação de fraturas hidráulicas geradas em laboratório; e a comparação entre dois métodos para a determinação de coeficientes de filtração (análises de NoIte e de curvas de volume de filtrado vs. tempo). Foram utilizados corpos de prova de rocha sintética e géis reticulados com diferentes concentrações de polímero. O simulador fisico é constituído por uma estrutura de reação projetada para corpos de prova cúbicos (lOxlOxIO) cm3, os quais foram submetidos a um estado tridimensional de tensões. Foram usadas diferentes vazões de injeção com o objetivo de investigar o efeito do cisalhamento sobre o coeficiente global de filtração. Foram geradas fraturas radiais horizontais com diâmetros próximos, recorrendo-se ao controle do tempo de propagação. Coeficientes de filtração obtidos via análise de Noite foram comparados com coeficientes provenientes de células de filtração estática, considerando-se condições experimentais similares. Os resultados foram discutidos, concluindo-se que a simulação fisica de fraturamento constitui uma ferramenta útil para a avaliação da eficiência de fluidos e que também pode fornecer estimativas de coeficientes de filtração. A metodologia utilizada no trabalho consistiu numa técnica relativamente simples para a comparação da eficiência de diferentes géis de fraturamento / Abstract: The fluid loss plays an important role in the design and placement of hydraulic fracturing treatments. The main objectives of this work were: the study of the fluid loss associated with the propagation of hydraulic fractures generated at laboratory; and the comparison of two distinct methods for estimating leakoff coefficients (NoIte analysis and the filtrate volume vs. square root oftime plot). Synthetic rock samples were used as well as crosslinked fluids in different polymer concentrations. The physical simulations comprised the confinement of cubic rock samples, (10x10xl0) cm3, in a load cell for the application of an in situ stress field. Different flow rates were employed in order to investigate shear effects on the overallleakoff coefficient. Horizontal radial fractures were hydraulically induced with approximate diameters, what was accomplished by controlling the injection time. Overall leakoff coefficients determined by means of NoIte analysis were compared to coefficients obtained from static filtration tests, considering similar experimental conditions. The research results indicated that the physical simulation of hydraulic fracturing may be regarded as an useful tool for evaluating the efficiency of fracturing fluids and that it can supply reliable estimates of fluid loss coefficients. The experimental methodology applied in this work turned out to be a considerably simple technique which allowed comparisons of fracturing gels pursuing different leakoff properties / Mestrado / Mestre em Engenharia de Petróleo
412

Estudo de tensões residuais em policarbonato moldado por injeção

Angelini, Joceli Maria Giacomini 20 December 1999 (has links)
Orientador: Lucia Helena Innocentini Mei / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-26T08:06:51Z (GMT). No. of bitstreams: 1 Angelini_JoceliMariaGiacomini_D.pdf: 3402380 bytes, checksum: 10d439c2c31170c351752786f195bcf1 (MD5) Previous issue date: 1999 / Resumo: O objetivo deste trabalho é mostrar os resultados encontrados nos estudos de tensão e deformação de amostras de policarbonato (PC) moldadas por injeção. A determinação quantitativa da tensão residual, neste polímero amorfo, era um desafio. Para isto, vários estudos foram conduzidos e algumas técnicas foram utilizadas. Corpos de prova de tração e impacto, com e sem tratamento térmico de alívio de tensões ("annealing") foram acompanhados por luz polarizada para comparação das linhas de tensão antes e após relaxação de tensões. O ensaio de impacto foi realizado com posterior análise do mecanismo de fratura. A aplicação da teoria do mecanismo de fratura elástico linear (MFEL) foi realizada e a tensão crítica, (sigma c, determinada. Foram realizados os ensaios de tração com os corpos de prova apropriados, em três diferentes velocidades, na temperatura ambiente; o módulo de Young, assim obtido, foi utilizado para cálculos posteriores de tensão e deformação. A técnica de Microscopia Eletrônica de Varredura (MEV) foi utilizada para analisar a superfície de fratura dos corpos-de-prova. Após os ensaios de tração, a estrutura diamante foi encontrada, inédita para policarbonato, mesmo à temperatura ambiente. Em pesquisa bibliográfica, até então, isto somente tinha sido encontrado para altas temperaturas. Espectroscopia Raman e Microscopia Óptica acoplada foram utilizadas, para microcorpos -de-prova de tração, sendo esta a aplicação pioneira a polímeros sem carga, para medidas de tensão e deformação. Corpos-de-prova em curvatura ou flexão também foram estudados. Foi tentada a construção de uma curva de calibração de tensão medida com "micro strain gage" ou micro-extensômetro, para baixa deformação, versus "shift" ou a alteração no espectro Raman.Medidas de deformação, por deslocamento na microscopia óptica, também foram tentadas, mas não houve significativas alterações nos comprimentos de onda das absorções Raman, nos espectros obtidos. Os melhores resultados na Espectroscopia Raman foram obtidos com aplicação de carga; por este meio, a posição do pico no espectro foi medida em função da força aplicada em uma determinada área, ou tensão. A faixa de carga aplicada foi no mesmo nível da tensão residual medida anteriormente pelo método do "hole drilling strain gage" para produtos de policarbonato [2]. As tensões residuais, tensões internas, tensões de moldagem, diferentes formas de tensões congeladas, tensões de tração, tensões de compressão, enfim, todas fazem parte do contexto total de tensão-deformação. Estes conceitos, bem como o acompanhamento de fissuras e trincas, devem também ser utilizados em estudos de termo e fotodegradações / Abstract: The aim of this work is to show the studies that have been made and the results found in stress and deformation of polycarbonate injection moulded sample. The quantitative evaluation of the residual stress in this amorphous polymer, was an challenge. For this, a lot of studies have been made and some techniques have been employed. The dumb-bell and impact test specimens, with and without "annealing", were followed by polarized light to compare the stress lines, before and after stress relaxation. The impact test has been made with later fracture mechanism analyses. The application of the linear elastic fracture mechanics (LEFM) theories have been made and the critical stress, sigma c, have been calculated. With the dumb-bell specimens, had been made in the tensile test at three different rates, at room temperature; the Young's Modulus here obtained was used for later calculations of stress and strain. Scanning electron microscopy (SEM) has been used for to see the fracture surface of the samples. After the tensile tests, the diamond structure had been found even at room temperature; in literature survey, until now, this only was found at high temperature. Raman spectroscopy and optical microscopy technique has been useful in micro dumb-bell specimens, to evaluation of stress, in one first application to polymers without fillers. Samples in bending state have been also studied. It was try to make the calibration curve of strain measured with strain-gauge, for low strain, versus the shift in Raman spectra. The measurement of strain, by displacement in optical microscope, also was tried, but no significally shift in Raman wave number was obtained. The best results have been got with application of load; in this way, the Raman spectral peak position have been measured in function of applied load in one determined area, or stress. The applied load range was in the same level of the residual stress measured earlier by the hole drilling strain gage method, for polycarbonate products. The residual stress, and ali kinds of stress citation, were understood in the whole of stress strain approach and this concept and evaluation of crazes and cracks should to be also used in thermal and photo degradation studies / Doutorado / Ciencia e Tecnologia de Materiais / Doutor em Engenharia Química
413

Modelagem de problemas da mecanica da fratura e propagação de trincas em fadiga / Modelling problems of fracture mechanics and fatigue crack propagation

Sato, Marcel 14 August 2018 (has links)
Orientador: Paulo Sollero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T01:32:47Z (GMT). No. of bitstreams: 1 Sato_Marcel_M.pdf: 15643379 bytes, checksum: 9ad3608b9de1e264891ac44ce87bbb5a (MD5) Previous issue date: 2009 / Resumo: Este trabalho apresenta uma ferramenta para modelar a propagação de múltiplas trincas por fadiga em modo misto para materiais isotrópicos, utilizando o Método dos Elementos de Contorno Dual. Este método é utilizado para realizar uma análise de tensões e deformações no sólido, de modo a proporcionar resultados confiáveis para o campo elástico na região ao redor da trinca. À partir destes resultados, os fatores de intensidade de tensão são obtidos utilizando-se a técnica da Integral J, realizando-se o desacoplamento dos modos através da decomposição do campo elástico em seus componentes simétricos e anti-simétricos. Os fatores de intensidade de tensão são utilizados para calcular o ângulo de propagação e tamanho de incremento pelo método da Mínima Densidade de Energia de Deformação. A vida em fadiga é obtida pela integração direta da expressão da Lei de Paris, modificada pelo modelo de fechamento de trinca. O algoritmo é validado com resultados experimentais para dois problemas envolvendo fratura em modo misto e fadiga. Em ambos os testes, foi utilizada a técnica de Correlação de Imagens Digitais para monitorar a propagação das trincas por fadiga e técnicas de processamento de imagens foram empregadas para analisar os resultados / Abstract: This work presents a tool to model problems of multiple site fatigue crack propagation in isotropic materials under mixed mode conditions, using the dual boundary element method. This method is used to make an analysis of tensions and deformations in the solid, providing reliable results for the elastic field in the region near the crack tip. The stress intensity factors are obtained using the J-integral technique and they are decoupled with a procedure based on the decomposition of the elastic field into its symmetric and anti-symmetric components. The crack propagation angle and the increment size are calculated through the minimum strain energy density criterion. The fatigue life is obtained through the integration of the Paris law expression modified by the crack closure model. The validation of the algorithm is made with experimental results for two mixed mode fracture problems with fatigue. In both cases, the digital image correlation technique was used to monitor the fatigue crack propagation during the tests and digital image processing techniques were used to analyze the result / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
414

Influencia do uso de lubrificantes no processo de estampagem profunda com chapas espessas de aço / Influence of the lubricant use in the process of deep drawing with thick steel sheeet metals

Silva, Marco Fabricio Lopes Pereira da 14 August 2018 (has links)
Orientador: Sergio Tonini Button / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T01:25:30Z (GMT). No. of bitstreams: 1 Silva_MarcoFabricioLopesPereirada_M.pdf: 6009072 bytes, checksum: 9390e6123ad97adcd3ad0d0f7f347dc6 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste trabalho foi avaliar a influência da lubrificação sobre os esforços do processo e produto durante o embutimento profundo de corpos com chapas metálicas, conforme ABNT NBR 5906: 1984 grau EPA de espessura 3,5mm e entender as causas da fratura no produto durante o embutimento sobre condições específicas de processo. Ocorrências de defeitos como trincas, acabamentos indesejáveis, estrangulamentos, entre outros, em componentes estampados desse gênero e nessa ordem de espessura, justificam avaliar como o lubrificante atua sobre as características do processo de embutimento e quais são seus efeitos sobre as características dimensionais do produto. Para avaliar a ocorrência da fratura dos corpos de prova, foi realizado o primeiro conjunto de experimentos (sem lubrificantes) planejados pelo método fatorial, com a intenção de selecionar os corpos de prova para a segunda fase de experimentos. Os resultados foram coletados e analisados, podendo-se concluir nessa primeira fase que a probabilidade de fraturar o corpo de prova é maior em função do diâmetro externo do blanque do que em função do raio da ferramenta e que, a partir dos testes estatísticos não foi evidenciada a influência do prensa chapa sobre a probabilidade de fraturar o corpo de prova. Também nota-se que a não atuação do prensa chapa favorece a diminuição da força máxima de embutimento pela maior influência do raio da ferramenta. Quanto à ocorrência da fratura dos corpos de prova no segundo conjunto de experimentos planejados pelo método fatorial, com o objetivo de avaliar o desempenho de cinco lubrificantes, verificou-se que não houve influência da lubrificação sobre os resultados de fratura. Novamente foi identificada a relação com o raio da ferramenta (R) e com a atuação do prensa chapa, reforçando a hipótese de sensibilidade do produto em função da geometria da ferramenta. Avaliando-se os tipos de lubrificantes sobre a estricção da parede do produto em pontos específicos, observou-se uma deformação significativa quanto comparada com os resultados sem a aplicação de lubrificantes. Os cinco lubrificantes selecionados para os ensaios não minimizaram o efeito de fraturas nos corpos de prova, porém foi evidenciado efeito nos esforços de embutimento, destacando-se dos demais o lubrificante semi-sintético Extrudoil 319 HT. / Abstract: The objective of this work was to evaluate the influence of the lubrication on the process and product during the deep drawing of metallic cups, as Brazilian standard ABNT NBR 5906:1984, degree EPA to thickness 3,5mm and to understand the causes of the cracking during deep drawing, on specific conditions of this process. Occurrences of defects as crack, undesirable finishing, necking, among others, in stamped components in this level of thickness, justify evaluating the lubricant on the characteristics of the deep drawing process and the effect on the dimensional characteristics of the product. To evaluate the occurrence of cracking in the cups, it was planned the first set of experiments (without lubricant) with the factorial design, to select the cups for the second phase of experiments. The results had been collected and analyzed, being able to conclude in this first phase that the probability to crack the cup is bigger in function of the external diameter of blank, in function of the diameter of the tool, and according to the statistical tests, there were not evidences of the influence of the blank holder on the probability for cracking. Also without the blank holder there was a reduction of the maximum force of deep drawing because the biggest influence of the diameter of the tool. To evaluate the occurrence of cracking of the cups a second phase of experiments was planned with the factorial design, with the objective to evaluate the performance of five lubricants. It was verified that there was not influence of the lubrication on the cracking results; however it was again identified the relation with the diameter of the tool and with the performance of the blank holder, strengthening the hypothesis of sensitivity of the product in function of the geometry of the tool. Evaluating the five lubricants influence on the reduction of area of the cup wall in specific points, it was observed a significant deformation when compared with the results without lubricant. The five lubricants selected for the tests had not minimized the effect of cracking, however evidenced the effect in the deep drawing load, being the semi-synthetic lubricant Extrudoil 319 HT the best of these five lubricants. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
415

Resistência à fratura de dentes que receberam restaurações adesivas de resina composta e porcelana / Fracture resistance of adhesively restored teeth with composite resin and ceramic restorations

Paulo Henrique Perlatti D'Alpino 21 December 2000 (has links)
Avaliou-se a resistência à fratura de dentes pré-molares superiores que receberam diferentes preparos cavitários (classe II-MOD) e restaurações diretas e indiretas de resina composta e restaurações indiretas de porcelana. Cinqüenta e seis dentes recém extraídos, hígidos, foram selecionados e divididos em 7 grupos: Grupo 1- hígidos, controle, não recebeu qualquer tratamento; Grupo 2- preparo cavitário com broca carbide n.º 245, produzindo cavidades retentivas, com ângulos internos arredondados, profundidade de 2 mm, abertura de istmo de metade da distância intercuspídea, caixa proximal com parede axial de 2 mm de extensão e 1,5 mm de profundidade, abertura de metade da dimensão vestíbulo-lingual, não sendo restaurado; Grupo 3 - recebeu somente preparo cavitário com ponta diamantada n.º 2136, produzindo cavidades com paredes divergentes para oclusal, ângulos internos arredondados, com as mesmas dimensões do preparo anterior, não sendo restaurado; Grupo 4 - recebeu o mesmo preparo que o grupo 2 e restaurou-se com resina composta aplicada na forma direta (Single Bond - 3M/ Z-250 – 3M); Grupo 5 - recebeu o mesmo preparo do grupo 3 e restaurou-se com resina indireta (Single Bond 3M/ Rely X- 3M/ Artglass-Kulzer); Grupo 6 - recebeu o mesmo preparo que o grupo 3, sendo restaurado com resina composta indireta (Single Bond 3M/ Rely X- 3M/ Targis- Ivoclar); Grupo 7 - mesmo preparo que o grupo 3, restaurado com restaurações indiretas de porcelana (Single Bond 3M; Rely X- 3M/ IPS Empress - Ivoclar). Submeteu-se os corpos de prova a testes de compressão axial, com um cilindro de aço (8 mm de diâmetro), acoplado a uma máquina de ensaios universal (Kratos), a uma velocidade de 0,5 mm/min, até que houvesse fratura de cúspide. Os valores obtidos foram os seguintes (em kgf): Grupo 1- 193,93 ± 24,46; Grupo 2- 108,56 ± 21,39; Grupo 3- 95,43 ± 17,73; Grupo 4- 147,65 ± 32,63; Grupo 5- 184,15 ± 56,49; Grupo 6- 183,81 ± 31,95; Grupo 7- 181,12 ± 40,49. Observou-se que os preparos cavitários reduziram significantemente a resistência dos dentes; não houve diferença significante na resistência dos dentes quando se comparou os diferentes tipos de preparo cavitário; os materiais restauradores contribuíram para que esses valores aumentassem, não se observando diferença estatística entre os grupos 4, 5, 6 e 7 e o grupo controle; houve um aumento significante na resistência quando se comparou os grupos 5, 6 e 7 (restaurações indiretas) em relação ao grupo 3 (preparado e não restaurado), o mesmo não sendo observado com o grupo 4 (restauração direta) em relação ao grupo 2 (preparado e não restaurado). / The purpose of this study was to evaluate the fracture resistance of teeth restored with direct and indirect restorations of composite resin and restored with indirect ceramic restorations. Fifty-six maxillary premolar teeth were selected and divided at random into seven groups; Group 1 (control): intact teeth; Group 2: MOD cavity preparations, ½ intercuspal distance, with rounded internal angles, convergent walls, unrestored; Group 3: MOD cavity preparations, ½ intercuspal distance, divergent walls; Group 4: same preparation as group 2, restored with direct composite resin (Single Bond/ Filtek Z250); Group 5: same as group 3, restored with indirect composite resin (Artglass-Kulzer/Single Bond/ Rely X); Group 6: same as group 3, restored with indirect composite resin (Targis-Ivoclar/ Single Bond/ Rely X); Group 7: same as group 3, restored with indirect ceramic restoration (IPS Empress – Ivoclar/ Single Bond/Rely X). The specimens were subject to a compressive axial load in a Universal testing machine at 0.5 mm/min by means of a steel bar (8 mm in diameter). The mean fracture strength obtained was (kgf): Group 1: 193,93 ± 24,46; Group 2: 108,56 ± 21,39 ; Group 3: 95,43 ± 17,73; Group 4: 147,65 ± 32,63; Group 5: 184,15 ± 56,49; Group 6: 183,81 ± 31,95; Group 7: 181,12 ± 40,49. There were no significant (p< 0.05) differences between intact teeth and teeth restored with indirect restorations. These results suggest that prepared teeth were significantly weaker than control group; teeth restored with direct and indirect composite resins were significantly more resistance to fracture than were similarly prepared but unrestored teeth. Restoring teeth with direct composite restoration increased the fracture resistance in relation to the control group, but was unable to strengthen them compared with unrestored teeth. These results showed that a bonded indirect restoration could be an ideal option for restoring teeth weakened by wide cavity preparation.
416

"Estudo comparativo da resistência às forças de compressão de uma coroa metalocerâmica fraturada e reparada com resina composta híbrida fotopolimerizável com um dente natural permanente e com uma coroa metalocerâmica íntegra" / Comparative study of the resistance to compression forces of a fractured metal ceramic crown and repaired with composite resin with a non-fractured metal ceramic crowns and a permanent natural tooth

Antonio Ruy Chaves Filho 28 November 2001 (has links)
As porcelanas odontológicas têm sido dos materiais restauradores estéticos aqueles que mais têm evoluído nos últimos anos. Tradicionalmente, elas são friáveis e incapazes de suportar deformações estruturais quando submetidas a stress. Quando usadas na construção de próteses parciais fixas, uma subestrutura metálica é necessária para impedir que se fraturem sob esforços oclusais. Forças de compressão aplicadas em uma porcelana suportada por metal, de tal forma que não seja possível a sua flexão, poderão ser suportadas em elevadas magnitudes. Entretanto, falhas podem acontecer manifestando-se normalmente por fraturas que exigem a intervenção do clínico no sentido de corrigi-las. Diversos são os métodos propostos para o reparo destas fraturas e as pesquisas desenvolvidas no sentido de se avaliar a união dos materiais restauradores às porcelanas. Neste trabalho, foi feita uma análise das possíveis causas de fratura das cerâmicas, os métodos de reparo indicados, materiais empregados para tal e a eficiência dos sistemas indicados frente às variáveis que envolvem o procedimento restaurador da porcelana. A proposta foi avaliar a resistência máxima às forças de compressão de reparos de fraturas de porcelana realizados com uma resina composta híbrida fotopolimerizável, empregando cargas estáticas comparando-a com a resistência de coroas metalocerâmicas íntegras e dentes naturais permanentes, usados como grupo controle. Os resultados mostraram que frente às forças de compressão aplicadas, a coroa metalocerâmica íntegra e o dente natural não apresentaram diferença estatisticamente significante. A coroa metalocerâmica reparada apresentou menor resistência que a coroa / The odontologic porcelains have been out of the esthetic restorative materials those, which have developed the most in the last years. Traditionally, they are brittle and unable to bear structural deformations when submitted to stress. When used in the building of partial fixed prothesis, one metallic framework is needed to avoid them to fracture under occlusal efforts. Forces of compression enforced on a metal supported porcelain in a way, which is not possible to bend, they could be beared in high magnitudes. However, failures can happen normally revealing themselves through fractures, which demand the intervention of the clinician in order to evaluate the association of the restorative materials to porcelains. In this study na analysis has been made of the possible causes of fractures of the ceramics, the indicated repairing methods, the materials used for it and, the efficiency of the variables, which involves the restorative procedure of the porcelain. The aim was evaluate the utmost resistance to the forces of compression in repairs of fractures of porcelain made with a light-cured hybrid composite resin, using static loads and comparing it with the resistance of the nonfractured metal ceramic crowns and permanent natural human teeth, used as control group The results have shown that in the presence of the compression forces loaded to non-fractured metaloceramic crown and the natural tooth have not exhibited statistically meaningful difference. The repaired metaloceramic crown has exhibited less resistance than the non-fractured metaloceramic one. However, there has not been statistically meaningful difference to the permanent natural tooth
417

Estudo comparativo entre a Via Lateral de Hardinge e o Acesso Minimamente Invasivo para o tratamento de fraturas intertrocantéricas com o Dynamic Hip Screw

Abreu, Eduardo Lima de, +5592984173208 12 September 2018 (has links)
Submitted by Eduardo Abreu (edmanaus@ufam.edu.br) on 2018-10-26T00:56:34Z No. of bitstreams: 4 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação.pdf: 1954872 bytes, checksum: b56ba2eefe6fa7643e129c6ca637b65c (MD5) Ata de defesa.pdf: 1221470 bytes, checksum: f23ff5f8f826754d96247c601a70d8ec (MD5) Carta para Autodepósito.pdf: 512686 bytes, checksum: 8ec68a1ea2fba104fa19e660b12a3db5 (MD5) / Approved for entry into archive by PPGRACI Cirurgia (ppgraci@ufam.edu.br) on 2018-10-26T05:48:21Z (GMT) No. of bitstreams: 4 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação.pdf: 1954872 bytes, checksum: b56ba2eefe6fa7643e129c6ca637b65c (MD5) Ata de defesa.pdf: 1221470 bytes, checksum: f23ff5f8f826754d96247c601a70d8ec (MD5) Carta para Autodepósito.pdf: 512686 bytes, checksum: 8ec68a1ea2fba104fa19e660b12a3db5 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2018-10-26T12:33:33Z (GMT) No. of bitstreams: 4 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação.pdf: 1954872 bytes, checksum: b56ba2eefe6fa7643e129c6ca637b65c (MD5) Ata de defesa.pdf: 1221470 bytes, checksum: f23ff5f8f826754d96247c601a70d8ec (MD5) Carta para Autodepósito.pdf: 512686 bytes, checksum: 8ec68a1ea2fba104fa19e660b12a3db5 (MD5) / Made available in DSpace on 2018-10-26T12:33:33Z (GMT). No. of bitstreams: 4 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertação.pdf: 1954872 bytes, checksum: b56ba2eefe6fa7643e129c6ca637b65c (MD5) Ata de defesa.pdf: 1221470 bytes, checksum: f23ff5f8f826754d96247c601a70d8ec (MD5) Carta para Autodepósito.pdf: 512686 bytes, checksum: 8ec68a1ea2fba104fa19e660b12a3db5 (MD5) Previous issue date: 2018-09-12 / Background: Intertrochanteric fractures are a public health problem, frequently high in the elderly. It is an ideally surgical teatment condition which makes this, a disease associed associated with serious morbidity. The technique fixation must be reproducible, less agressive, with low medical complication rates and good functional results. The Dynamic Hip Screw (DHS) system is one of several implants options used worldwide for the treatment of these fractures, and its installation through MIPO approach (Minimally Invasive Plate Osteosynthesis) is poorly documented in world literature. Objectives: The objective of this study is to compare the fixation techniques of intertrochanteric fractures with DHS, using the Hardinge approach and a minimally invasive approach, while assessing pain levels, hematimetric loss, inflammatory alterations, as well as evaluating functional aspects in the immediate post-operative follow-up. Method: This is a randomized, double-blind clinical trial in which 70 patients underwent osteosynthesis by the DHS system. The patients were divided into a test group, in which the approach used was MIPO and one control, with the Hardinge approach. The MIPO’s group showed a lower degree of postoperative pain, compared to the group treated with the Hardinge approach. Results: The Hardinge approach group presented an elevation of approximately 2 points on the pain scale in the immediate post-operative follow-up, while the patients in the test group showed a drop of 3 points on this scale (p <0.01). This result was reflected in the lower consumption of opioid medication. Elevation of the operated limb in the immediate postoperative follow-up was achieved by 73% of the patients in the test group and by only 18% of the control group. Patients submitted to the minimally invasive treatment also had a lower rate of hematimetric loss. The intertrochantericfracturefixation using the DHS system, through a minimally invasive approach, was superior to the treatment with the traditional Hardinge approach. The patients presented lower hematimetric loss (p <0.01) and the degree of postoperative pain was considerably lower (p<0.01). Conclusions: Because this is a treatment associated with serious morbidity, a less aggressive surgical option during the procedure of the intertrochanteric fractures, should be considered. The minimally invasive approach was superior to the traditional Hardinge approach and should therefore be a trend in the treatment of these fractures. / Justificativa: As fraturas intertrocantéricas são um problema de saúde pública, com frequência elevada na população idosa. É uma condição de tratamento idealmente cirúrgico, o que faz dessa doença uma entidade de grave morbidade. A técnica escolhida para a fixação dessas fraturas deve ser reprodutível, pouco agressiva, com baixas taxas de complicações e bons resultados funcionais. O sistema Dynamic Hip Screw (DHS) é uma das várias opções de síntese utilizadas em todo mundo para o tratamento dessas fraturas, e sua instalação através de acesso cirúrgico minimamente invasivo (MIPO – Minimally Invasive Plate Osteossynthesis) é pouco documentada na literatura mundial. Objetivos: O objetivo do estudo é comparar as técnicas de fixação de fraturas intertrocantéricas, tratadas com o DHS, através das vias de acesso lateral de Hardinge e minimamente invasiva, avaliando o grau de dor, a perda hematimétrica, as alterações inflamatórias, bem como avaliar os aspectos funcionais no seguimento pós-operatório imediato (POI). Método: Trata-se de um ensaio clínico randomizado, duplo cego, no qual 70 pacientes foram submetidos à osteossíntese pelo sistema DHS. Os pacientes foram divididos em um grupo teste, em que a via de acesso utilizada foi a MIPO e um controle, com a via de Hardinge. O grupo submetido ao tratamento pela via MIPO apresentou menor grau de dor pós-operatória, em comparação ao grupo tratado pela via de Hardinge. Resultados: Os pacientes operados pela via de Hardinge apresentaram uma elevação de aproximadamente 2 pontos na escala de dor, no POI, enquanto os pacientes do grupo teste apresentaram queda de 3 pontos nessa escala (p<0,01). Esse resultado refletiu-se no menor consumo de medicação opioide pelo grupo teste. Nos exames físicos realizados no POI, 59% dos pacientes do grupo teste conseguiram sentar-se com leve auxílio, no leito, contra 18% do grupo controle. A elevação do membro operado no POI foi conseguida por 73% dos pacientes do grupo teste e por apenas 18% do grupo controle. Os pacientes submetidos ao tratamento pela via minimamente invasiva também apresentaram uma menor taxa de perda hematimétrica (p<0.01). A fixação das fraturas intertrocantéricas com o sistema DHS instalado por via minimamente invasiva mostrou-se superior ao tratamento com a via de acesso tradicional de Hardinge. Os pacientes apresentaram menor perda hematimétrica (p<0,01) e o grau de dor pós-operatória foi consideravelmente menor (p<0,01). Conclusões: Por se tratar de um tratamento com importante morbidade, a menor agressividade cirúrgica na fixação das fraturas intertrocantéricas deve ser considerada e a via de acesso minimamente invasiva mostrou-se superior à via tradicional de Hardinge, devendo, portanto, ser uma tendência no tratamento dessas fraturas.
418

Sinais clínicos de fratura da base do crânio e seu desempenho no diagnóstico dessa lesão / Clinical signs associated with skull base fracture and its performance on the diagnosis of this injury.

Cibele Andres Solai 17 July 2013 (has links)
Introdução: A fragilidade dos sinais clínicos de fratura de base do crânio (FBC) para o diagnóstico dessa lesão, contraposta pela relevância atribuída a esses sinais, motivou a atual investigação, tendo em vista, sobretudo, a importância do diagnóstico dessa fratura nas intervenções iniciais ao doente traumatizado. Objetivos: Descrever o desempenho dos sinais clínicos de FBC para o diagnóstico dessa lesão; verificar o desempenho do hematoma periorbital e/ou rinorreia para diferenciar a fratura de fossa anterior das demais fraturas da base do crânio; descrever o tempo pós-trauma de aparecimento dos sinais clínicos em vítimas com e sem FBC; descrever o desempenho dos sinais de FBC na identificação precoce desse tipo de lesão; verificar a associação entre a presença de sinais clínicos de FBC e as variáveis idade do paciente e gravidade do trauma craniencefálico (TCE). Método: Estudo prospectivo do tipo follow up realizado por meio de observação estruturada de vítimas de TCE até 48 horas após trauma. Foram estudados indivíduos com idade 12 anos, com TCE contuso, atendidos na Unidade de Emergência Cirúrgica da Casa de Saúde Santa Marcelina entre agosto de 2012 e janeiro de 2013. Essa investigação foi focada nos sinais de FBC clássicos, apreciados rotineiramente na prática assistencial: hematoma periorbital, hematoma retroauricular, otorreia e rinorreia. Nas análises, o padrão-ouro para diagnóstico de FBC foi a tomografia computadorizada ou a visualização direta dessa fratura em cirurgia. Para avaliar o desempenho dos sinais clínicos de FBC, foi calculado seu valor preditivo positivo (VPP) e negativo (VPN), a sensibilidade, a especificidade e a acurácia. O teste quiquadrado foi aplicado para verificar as associações entre as variáveis. Resultados: A casuística foi composta de 136 vítimas com TCE, das quais 28 tiveram FBC. Os sinais clínicos de FBC observados nas primeiras 48 horas pós-trauma apresentaram VPP = 25,7%, VPN = 94,3%, sensibilidade de 92,8%, especificidade de 30,5% e acurácia de 43,4%. Quando detectados na primeira hora, os sinais clínicos tiveram o seguinte desempenho: VPP = 27,1%, VPN = 86,4%, sensibilidade de 67,8%, especificidade de 52,8% e acurácia de 55,9%. Vítimas com e sem FBC tiveram evidências clínicas desse tipo de fratura após a primeira hora do trauma, 21,0% entre 1 e 6 horas e 9,0% após 6 horas. Entre os indivíduos com FBC e sinais clínicos, 26,9% tiveram manifestação mais tardia desse tipo de lesão. A presença de sinais clínicos de FBC em vítimas de TCE se associou com a sua gravidade (p = 0,041 e 0,002), porém não esteve relacionada com a idade (p = 0,350). Nas vítimas com FBC, as evidências clínicas específicas de lesão de fossa anterior tiveram acurácia de 53,6%, VPP = 42,8%, VPN = 85,5%, sensibilidade de 90,0% e especificidade de 33,3%. Conclusão: Os resultados do atual estudo contraindiciam a valorização dos sinais de FBC na decisão do uso da via nasal para introdução de cateter e cânulas no atendimento inicial da vítima de trauma, visto que é baixa a acurácia desses sinais, sua presença tem pouco valor clínico e a ausência apresenta bom valor preditivo tardiamente. / Introduction: The fragility of the clinical signs for skull base fracture (SBF) diagnosis and, on the other hand, the importance attributed to these signals motivated this research, especially because of the importance of the fracture diagnosis in the first interventions on the trauma patient. Objectives: To describe the performance of clinical signs on the SBF diagnosis; to verify the performance of periorbital hematoma and/or rhinorrhea to differentiate a anterior fossa fracture from other skull base fractures; to describe the trauma clinical signs onset in victims with or without SBF; to describe the signs performance in the early identification of SBF; to verify the association between SBF clinical signs and age of the patient and severity of head injury (SHI) variables. Methods: Prospective follow-up conducted through structured observation of skull brain trauma (SBT) victims within 48 hours after trauma. The study was about subjects aged 12 years with blunt SBT, treated at the Emergency Surgical Unit at the Santa Marcelina Hospital between August 2012 and January 2013. This investigation was focused on classical SBF signs routinely examinated in healthcare practice: periorbital hematoma, retroauricular hematoma, otorrhea and rhinorrhea. In the analysis, the gold standard for SBF diagnosis was computed tomography or direct visualization of the fracture on surgery. To evaluate the performance of SBF clinical signs, it was calculated its positive predictive value (PPV) and negative predictive value (NPV), sensitivity, specificity and accuracy. The chi-square test was used to assess relationships between variables. Results: The sample consisted of 136 SBT victims, 28 of whom had SBF. Clinical signs of SBF observed in the first 48 hours post-trauma showed PPV 25.7%, NPV 94.3%, sensitivity 92.8%, specificity 30.5% and accuracy 43.4%. When detected in the first hour, the clinical signs performed as follows: PPV 27.1%, NPV 86.4%, sensitivity 67.8%, specificity 52.8% and accuracy 55.9%. Victims with or without SBF showed clinical evidence of this kind of fracture after the first hour of injury, 21,0% between 1 and 6 hours and 9,0% after 6 hours. Among individuals with SBF and clinical signs, 26.9% had a later manifestation of this lesion. The presence of SBF clinical signs in SBT was associated with severity (p = 0.041 and 0.002), but was not related with age (p = 0.350). In victims with SBF, specific clinical evidence of anterior fossa injury had an accuracy of 53.6%, PPV 42.8%, NPV 85.5%, sensitivity 90,0% and specificity 33.3%. Conclusion: The results of this study contraindicated the recovery of SBF signs in the decision of the nasal cannula use and catheter placement in the initial care of the trauma victim, since the accuracy of these signals is low, their presence has little clinical value and the absence has good predictive value later.
419

Avaliação eletromiográfica do músculo masseter nos pacientes portadores de fratura de face / The electromyographic study of masseter muscle in patients with facial fracture

Gabriel Denser Campolongo 16 April 2012 (has links)
Este estudo analisou por meio de um eletromiógrafo de superfície as atividades dos músculos masseteres, direito e esquerdo, de 30 pacientes com diagnóstico de fratura de ossos da face, com uma média de 1,33 fraturas por paciente, em quatro momentos, no pré-operatório e nos pós-operatórios equivalentes ao 7°, 30° e 60° dias posteriores à cirurgia. Considerou-se o valor de cada medida, a média entre três contrações máximas isométricas voluntárias de duração de cinco segundos cada uma. Os paciente foram agrupados de acordo com o diagnóstico da fratura, sendo com fratura da mandíbula 50%, fratura do zigomático 33%, fratura da maxila 10% e com fraturas associadas 6,7%. Os pacientes apresentaram menor atividade dos músculo masseter no período pré-operatório, quando comparado a valores considerados normais, em todos os grupos de fraturas, seguida de queda acentuada no pós operatório de 07 dias, sendo que todos os grupos apresentaram recuperação da atividade em 60 dias, porém abaixo do valor normal encontrado na literatura. Os valores médio observados foram em ordem decrescente: fratura de zigomático, fratura de mandíbula, fratura de maxila e fraturas associadas. As fraturas de mandíbulas unilaterais apresentaram maiores valores que as fraturas bilaterais na maioria dos tempos. Houve diferença altamente significante na comparação da evolução da atividade do músculo masseter direito e esquerdo para as fraturas de mandíbula e de zigomático, sendo que na comparação par a par houve diferença significante entre a maioria dos grupos. / This study analyzed using a surface electromyographic activity of the masseter muscles, right and left, of 30 patients with fractures of facial bones, with an average of 1.33 fractures per patient, four times, the pre-operative and postoperative equivalent to the 7th, 30th and 60th days after surgery. It was considered the value of each measurement, the average of three isometric maximum voluntary contractions for five seconds each. Patients were grouped according to the diagnosis of fracture, 50% of the mandible fracture, 33% of the zygomatic fracture, 10% of maxilla fracture and 6,7% with associated fractures. The patients showed lower activity of the masseter muscle in the preoperative period, when compared to normal values in all groups of fractures, followed by a sharp drop in the postoperative period of 07 days, and all groups showed a recovery of activity in 60 days, but below the normal value found in the literature. The average values were observed in decreasing order: zygomatic fracture, mandible fracture, maxilla fracture and associated fractures. The unilateral jaw fractures showed higher values than the bilateral fractures in most of the times. There was a highly significant difference in comparing the evolution of the activity of the masseter muscle right and left to the mandibular and zygomatic fractures, if compared pairwise significant difference between most groups.
420

Desenvolvimento de métodos alternativos para a avaliação da resistência à fratura por fluência de resinas de polietileno utilizadas para a extrusão de tubos de água. / Development of alternative methods to the assessment of the creep fracture resistance of polyethylene resins used for the extrusion of water pipes.

Fabiano Moreno Peres 23 August 2005 (has links)
O polietileno tem sido muito empregado em transmissão de água potável, particularmente em ramais prediais. Este polímero apresenta vantagens em relação a seus concorrentes, como flexibilidade, baixo preço, facilidade de instalação e resistência à corrosão. Os tubos fabricados com polietileno de alta densidade –PEAD, como o material é genericamente conhecido na indústria de saneamento básico no Brasil - são suscetíveis de apresentar falhas em serviço por fratura em fluência, as quais provocam vazamentos e perdas de água e incorrem em maiores custos de manutenção. Os principais fatores que influenciam a vida dos tubos de polietileno são: material, meio, condições de carga e técnicas de instalação. A busca de melhores materiais tem levado a indústria petroquímica ao contínuo desenvolvimento de novas resinas, com maior resistência às falhas, que ocorrem através do crescimento lento de trincas. Essa resistência à falha em serviço dos tubos geralmente é avaliada através de ensaios de resistência à pressão hidrostática interna de longa duração, realizados em diferentes temperaturas. Nestes ensaios observa-se que o PEAD apresenta comportamento dúctil (acompanhado de significativa deformação plástica) e falha em menor período de tempo a níveis elevados de tensão, enquanto que em níveis mais baixos de tensão o material apresenta falhas com aparência frágil - sem deformação plástica visível apreciável - após longos períodos de tempo. As falhas em serviço são predominantemente deste último tipo. Esta transição 'dúctil-frágil' no comportamento do material, pelo menos ao nível da falha macroscópica, é muito importante e precisa ser bem compreendida pois pode abreviar a vida útil do tubo através de falhas precoces. Dados de tensão circunferencial versus tempo de ruptura dos tubos podem ser plotados em escala bi-logarítmica, formando o que se conhece na prática industrial por 'curva de regressão', a qual é linear, com inclinação negativa e com maior inclinação (em módulo) na região correspondente às falhas do modo frágil. Dessa forma, a transição 'dúctil-frágil' apresenta-se na 'curva de regressão' como um ponto de inflexão. A tensão de transição dúctil-frágil é característica de uma dada formulação (composto) e não é facilmente determinada em ensaios conduzidos à temperatura ambiente. Apesar de sua ampla aceitação na indústria os testes de resistência à pressão hidrostática interna de longa duração devem ser criticados pois são muito longos, caros e pouco práticos para efeito de controle de qualidade dos tubos de polietileno. Além disso, a maioria dos dados são coletados a altas pressões internas (ou seja, na região 'dúctil') para economizar tempo, enquanto que os tubos operam na região 'frágil'. A filosofia desses testes, como empregados na indústria, também implica que o tempo de falha é uma propriedade do material, enquanto que fatores extrínsecos, como defeitos introduzidos durante a instalação, podem reduzir o tempo de nucleação da fratura, levando à falha precoce. O crescente emprego de tubos de polietileno em sistemas de distribuição de água, além de outras aplicações, como em sistemas de gás, requer o desenvolvimento de novos métodos de avaliação de desempenho, que levem em conta não apenas o tempo de falha como também os mecanismos de fratura. Busca-se desenvolver métodos de laboratório, de curta duração, para se estabelecer o comportamento dos tubos a longo prazo, principalmente para prevenir falhas precoces, do tipo frágil, dentro do período de vida útil esperado. A mecânica da fratura é justamente a disciplina que estuda o comportamento dos materiais na presença de trincas. Neste sentido duas abordagens são propostas no presente trabalho: 'Ramp Test' e o método do Trabalho Essencial de Fratura. O método do 'ramp test' permite estimar a tensão crítica correspondente à transição dúctil-frágil da 'curva de regressão' a partir de ensaios simples de tração. Por outro lado, o método do Trabalho Essencial de Fratura permite estimar diretamente as partes essencial e não essencial do trabalho específico de fratura. São analisadas cinco resinas provenientes de fornecedores tradicionais de matérias-primas para a produção de tubos de polietileno e duas outras resinas, desenvolvidas para outros fins. Os resultados permitem concluir que os ensaios propostos são viáveis como substitutos ou complementares ao ensaios de resistência à pressão hidrostática na avaliação da tendência de tubos de polietileno apresentarem falhas em serviço. / Polyethylene has been largely used in potable water distribution systems, mainly in service lines. This polymer offers many advantages over its competitors: flexibility, low cost, ease installation and corrosion resistance. Pipes made with high density polyethylene – HDPE, the generic designation of the material in the sanitation industry in Brazil – fail in service by fracture due creep, giving rise to leakage and water losses, resulting in higher maintenance costs. Main factors that affect the service life of polyethylene pipes are: material, environment, load and settlement. The search for improved materials leads the petrochemical industry to the continuous development of new resins, with increased resistance to failure, which occurs via slow crack growth. This resistance to in-service failure is usually measured in long-term hydrostatic strength tests, at different temperatures. In these tests HDPE behaves like ductile material (followed by significant plastic deformation) and fails in lower period of time under high stress levels, whereas under lower stress levels it fails in a brittle-like mode - with no visible permanent plastic deformation - after longer times. Failures in service are mainly brittle-like. This ductile-fragile transition in the behavior of the material at least at macroscopic scale, is very important and must be well understood, because it can abbreviate the service life of the tube, through early failure. Time-stress failure data can be ploted in bi-log scale to form what is known in the industrial praxis as regression curve, which is linear, with negative slopes, and a larger slope in modulus for the brittle-like fracture mode. In this way, the ductile-fragile transition appears as a point of inflection. The 'ductile-to-brittle' transition stress is claracteristic of a given formulation and is not easily determined in tests conducted at room temperatures. In spite of its widespread acceptance in the industry, the long-term hydrostatic strength test must be criticized because it has long duration, is expensive and not practical for pipes’ quality control. Beside that, most of the data are collected at high inner pressures to save time, while the tube is expected to operate in the 'brittle-like' region. The philosophy of these tests, as used in the industry, also implies that the time-to-failure is a material property, while extrinsic factors may shorten the fracture nucleation time, leading to a premature failure. The rising use of polyethylene pipes in water distribution systems, beside other applications as in gas systems, requires the development of new performance evaluation methods, that take into account not the time to failure but also the fracture mechanisms. It is desirable for developing short-term laboratory tests to establish the long-term behavior of pipes, to prevent premature brittle-like failures in the desired service life. Fracture mechanics is just the subject which studies the behavior of materials in the presence of cracks. In this way, two approaches are suggested for the present work : 'ramp test' and the Essential Work of Fracture method. The 'ramp test' method allows to estimate the critical stress that corresponds to the ductile-brittle transition in the regression curve using standard tensile test samples. On the other hand, the Essential Work of Fracture allows a direct estimation of the essential and the non-essential parts of the specific work of fracture. Five different resins for production of polyethylene pipes obtained from traditional raw material suppliers and two other resins designed for other purposes are analysed. The results allow to conclude that the suggested tests are feasible as substitutes or complementaries to the long-term hydrostatic stress tests to evaluate the tendency of the polyethylene pipes to present service failures.

Page generated in 0.0748 seconds