• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 44
  • 44
  • 27
  • 22
  • 13
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Fraturas em crianças e adolescentes atendidos em hospital de trauma do Recife: associação com uso prévio de glicocorticoides?

MELO, Verônica Maria Pinho Pessôa 01 July 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2017-04-07T13:15:48Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Mestrado Verônica Melo CCS.pdf: 1393412 bytes, checksum: ba56180c890511d0089ae952978dcc15 (MD5) / Made available in DSpace on 2017-04-07T13:15:48Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Mestrado Verônica Melo CCS.pdf: 1393412 bytes, checksum: ba56180c890511d0089ae952978dcc15 (MD5) Previous issue date: 2016-07-01 / Introdução: o uso crônico de glicocorticoides é considerado a principal causa de osteoporose secundária e iatrogênica. Existem poucos estudos associando fraturas ao uso de glicocorticoides na faixa etária pediátrica. Eles poderiam ajudar na criação de abordagens preventivas e terapêuticas. Objetivos: avaliar se o uso de glicocorticoides, nos 12 meses precedentes, associou-se à ocorrência de fraturas em crianças e adolescentes; identificar a frequência de asma e outras doenças; comparar o perfil demográfico, o tipo de trauma, o índice de massa corpórea, a prática de exercício físico, a ingesta de leite e o tabagismo passivo domiciliar nos grupos com e sem fratura; verificar a frequência de deficiência de vitamina D. Métodos: no período de abril a outubro de 2015, um estudo tipo caso controle foi conduzido em crianças e adolescentes vitimadas por trauma, com e sem fratura, a partir da análise dos dados coletados. Resultados: foram estudados 104 pacientes, 50 com fratura e 54 com trauma, mas sem fratura. Ao todo, 80,4% eram meninos e 40,4% estavam na faixa etária de 10 a 14 anos. O uso prévio de glicocorticoides ocorreu em 15,4% do total, sem diferença estatisticamente significante entre os dois grupos. Entre 39 pacientes com fratura e que dosaram a vitamina D, 47,2% tinham níveis séricos < 30ng/ml. A prática de exercício físico associou-se a um aumento em 2,2 vezes no risco para fratura. Conclusões: este estudo não mostrou associação entre o uso prévio de glicocorticoides e a ocorrência de fraturas em crianças e adolescentes. A faixa etária de 10 a 14 anos, o trauma grave e o exercício físico associaram-se com um maior risco para fraturas. Cerca de metade de uma amostra dos pacientes com fratura apresentou níveis insuficientes/deficientes de vitamina D, mesmo em região tropical. / Introduction: Osteoporosis is not exclusive to older adults and manifests by fractures. Chronic glucocorticoid use is considered the main cause of secondary and iatrogenic osteoporosis. Few studies have related fractures to the use of glucocorticoids in children and adolescents. Such studies could be useful for the development of preventive and therapeutic strategies. Objectives: To assess whether glucocorticoid use in the past 12 months is associated with the occurrence of fractures in children and adolescents; to identify the frequency of asthma and other diseases; and to compare the demographic profile, type of trauma, body mass index, physical activity, milk intake, and household exposure to cigarette smoke of groups with and without fractures; to verify the frequency of vitamin D insufficiency/deficiency. Methods: A case-control study, conducted from April to October 2015, analyzed the data of trauma children and adolescents with and without fractures. Results: A total of 104 trauma patients were studied, 50 with and 54 without fractures. In all, 80.4% were males, and 40.4% were aged 10 to 14 years. Previous glucocorticoid use occurred in 15.4% of the sample, without significant difference between the groups. Of the 39 fracture patients with measured serum vitamin D levels, 47.2% had levels < 30ng/ml. Physical activity was associated with a 2.2-fold risk of fractures, but without significance in multivariate analysis. Conclusions: This study did not find an association between previous glucocorticoid use and the occurrence of fractures in children and adolescents. In 10- to 14-year-olds, severe trauma and physical activity were associated with higher risk of fractures. About half the fracture sample had insufficient/deficient vitamin D levels, despite residing in a tropical region.
22

Análise mecânica e fotoelástica de quatro diferentes métodos de fixação em fraturas de corpo mandibular / Mechanical and photoelastic analysis of four different fixation methods for mandibular body fractures

Rodrigues, Danillo Costa, 1981- 24 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T15:32:49Z (GMT). No. of bitstreams: 1 Rodrigues_DanilloCosta_D.pdf: 786712 bytes, checksum: 20e5c6c3c2775a5b2c547eae752381d0 (MD5) Previous issue date: 2014 / Resumo: O propósito do presente estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fotoelástica, quatro métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de poliuretano e resina fotoelástica. O trabalho foi dividido em quatro grupos: O grupo I, foi fixado com duas placas do sistema 2,0mm, uma na zona de tensão e outra na zona de compressão mandibular. No grupo II, utilizou-se uma placa do sistema 2,0mm na zona central da mandíbula e uma barra de Erich na zona dentada. O grupo III, foi fixado com uma placa do sistema 2,4mm na zona de compressão e uma barra de Erich na zona dentada. E no grupo IV, foi empregada uma placa do sistema 2,0mm na zona de tensão e uma placa do sistema 2,4mm na zona de compressão. Os métodos de fixação utilizados em cada grupo foram semelhantes em ambos os testes. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®. Os valores foram analisados pelo teste de Shapiro-Wilk. Em seguida, foi aplicada a Análise de Variância (ANOVA), Kruskal-Wallis e posteriormente, o teste de Tukey e Mann-Whitney com correção de Bonferroni. Para a análise do teste fotoelástico, as hemimandíbulas em resina fotoelástica foram fotografadas quando a máquina de ensaio registrou o deslocamento final de 3mm e as franjas formadas no substrato foram avaliadas de forma qualitativa. Os resultados dos testes mecânicos indicaram que o grupo II apresentou menor resistência, seguido dos grupos I, IV e III. O teste fotoelástico confirmou a maior formação de tensão no grupo de menor resistência mecânica. Dessa forma concluiu-se que em fraturas lineares de corpo de mandíbula a utilização de placa do sistema 2,4mm apresentou maior resistência e que o emprego de apenas uma placa do sistema 2,0mm na zona central apresentou maior tensão / Abstract: The purpose of this study was to evaluate comparatively through linear load testing and photoelastic analysis, four methods of fixation in simulated fractures on polyurethane hemimandibles body and photoelastic resin. The study was divided into four groups: Group I was fixed with two plates of 2.0 mm system, one in the tension zone and another in compression zone. In Group II, it was used a 2.0 mm plate in the neutral zone and an Erich bar. Group III was fixed with a 2.4 mm plate in the compression zone and an Erich bar. The group IV was employed a 2.0 mm plate in tension zone and a 2.4 mm plate in the compression zone. The fixation methods used in each group were similar in both tests. Linear load testing was performed using an Instron® mechanical universal testing machine. After the tests, the values were analyzed by the Shapiro-Wilk test, Analysis of Variance (ANOVA), Kruskal -Wallis test and subsequently the Tukey test, and Mann-Whitney test with Bonferroni correction. For the analysis of photoelastic test, the hemimandibles were photographed in photoelastic resin when the testing machine recorded the final displacement of 3mm and the fringes formed on the substrate were evaluated qualitatively. The results of mechanical tests indicated that the group II had lower resistance, followed by the groups I, III and IV. The photoelastic test confirmed the increased formation of tension in the group of lower mechanical strength. Thus, it was concluded that in linear mandibular body fracture using the system board 2.4 mm presented more resistance and the use of only one 2.0 mm plante in the central area of the mandible showed higher tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
23

Análise da resistência mecânica e fractográfica de placas de titânio do sistema 1,5mm e dois métodos de fixação em fraturas simuladas em corpo de hemimandíbula de alumínio / Mechanical and fractographic analysis of 1,5mm titanium platesin two methods of fixation in simulated body fractures of aluminum hemimandibles

Rodrigues, Danillo Costa, 1981- 23 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:35:55Z (GMT). No. of bitstreams: 1 Rodrigues_DanilloCosta_M.pdf: 1685806 bytes, checksum: 0e90fd8fb32a562bcf7161f1f78bfab7 (MD5) Previous issue date: 2013 / Resumo: O presente estudo teve como propósito analisar a resistência mecânica de duas marcas de fixação do sistema 1,5mm através de teste mecânico de carregamento linear em dois métodos de fixação em modelos de hemimandíbulas de alumínio com fraturas simuladas e realizar análise fractográfica. Foi realizada a confecção de quatro estruturas de alumínio semelhantes a hemimandíbula, sendo utilizada duas hemimandíbulas para cada grupo de estudo. As mesmas foram fixadas com placas e parafusos das marcas Tóride® e Traumec®. No grupo I foi empregada uma placa reta de titânio de quatro furos na zona de compressão e outra na zona de tensão mandíbular; e no grupo II, foi empregada apenas uma placa reta de quatro furos na zona neutra. Para os testes mecânicos, foi utilizada a máquina para ensaio universal mecânica Instron® modelo 4411 até ocorrer a falha total do sistema de fixação (fratura da placa). Em seguida, as amostras foram submetidas a análises fractográficas das superfícies fraturadas com microscópio eletrônico de varredura FEI®. Foi aplicada a Análise de Variância (ANOVA) dois fatores e o teste de Tukey com significância de 5%. A fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01) em relação ao grupo de apenas uma placa, independente da marca comercial. A marca Tóride® apresentou média de deslocamento de pico maior que as placas Traumec® quando avaliadas nos grupos com uma placa e extensão de carga no deslocamento de 5mm. As amostras romperam por sobrecarga dúctil, por falha mecânica caracterizada por dano alveolar / Abstract: The purpose of this study was to analyze the mechanical strength of two brands of 1.5 mm system fixation through mechanical linear load test in two fixation methods in aluminum hemimandibles with simulated body fractures and perform fractographic analysis of the samples. Four aluminum structures similar to hemimandibles were fabricated with a linear sectioning simulating a fracture of mandibular body and two hemimandibles were used in each group for posterior fixation with plates and screws with two national brands: Toride® and Traumec®. The group I was fixed with a straight titanium plate with four holes in the compression zone and another one in the tension zone. Group II was fixed with a straight plate with four holes in the neutral zone. For mechanical testing, a universal mechanical testing Instron ® Model 4411 was used and the test was made until final failure of the system (fracture plate). Then, the samples were submitted to fractographic analysis through a scanning electron microscope FEI ®. A analysis of variance (ANOVA) Two-way and Tukey test with 5% significance (?= .05) were applied for statistical analysis. The fixation method with two straight plates showed a higher load resistance (p<0.01) when compared to the group of only one plate, regardless of the brand. The brand Toride® showed an average of peak displacement higher than Traumec® when the groups with only one plate with the extension of 5mm were evaluated. All the samples fractured by ductile overload, characterized by alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
24

Resistencia a flexão de fixação em osteotomia de costela bovina, variando o numero, a localização e a extensão das placas

Trivellato, Alexandre Elias 12 April 2001 (has links)
Orientador: Luis Augusto Passeri / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-31T15:14:06Z (GMT). No. of bitstreams: 1 Trivellato_AlexandreElias_D.pdf: 3724190 bytes, checksum: f29e801dbdb08b31267899c2943a54d9 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a estabilidade da fixação promovida por placas e parafusos de titânio do sistema de 2,0 mm, realizada em osteotomia de costela bovina submetidas ao teste de resistência à flexão variando o número, a extensão e a localização das placas. Do teste de resistência à flexão, foram obtidos valores de carga aplicada e de deslocamento na área da osteotomia. Os valores foram avaliados por meio do teste de Tukey em nível de significância de 5%. Na carga aplicada foi observado melhor comportamento quando da utilização de duas placas de seis furos ou duas placas sendo uma de seis furos na base e de quatro furos na região superior. Em seguida, de duas placas de quatro furos e, em ordem decrescente, mas sem variação quanto ao tamanho das placas, por uma na porção superior e finalmente por uma na base. Quanto ao deslocamento, não houve variação pela extensão da placa, onde o menor valor foi observado para uma placa na posição superior e o pior com uma placa em borda inferior, não havendo diferença com duas placas relacionadas ao maior ou ao menor deslocamento / Abstract: The aim of this study was to evaluate the stability fixation promoted by titanium plates and screws of 2.0mm system. It was done in vitro by using 2.0mm system in osteotomies carried out in bovine ribs thereafter submitted to bending test changing the number, the extension, and the location of the plates. From bending tests were obtained the load applied and the gap between the superior cortices of bone in the osteotomy area. The values were compared through Tukey test with 5% of significance. Considering the applied load, the best results were seen when either two 6-hole plates or a combination of 6 hole and 4-hole were used, the former in the basis and the later superiorly. Those were followed by the results obtained with using two 4-hole plates. Lower applied loads were obtained, despite of the size, using only one plate superiorly and only one in the basis. Related to gap between the superior cortices of bone there was no influence of the plate extension, and the lower value was obtained with one plate superiorly and the higher was obtained with one plate in the basis / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
25

Prevalência de alterações ósseas e risco de fraturas em pessoas vivendo com HIV/Aids em uso crônico de antirretrovirais

Vidal, Vânia Vieira de Melo Fagundes. January 2017 (has links)
Orientador: Lenice do Rosário Souza / Banca: André Pentean Trindade / Banca: Cilmery Suemi Kurokawa / Banca: Érika Ferrari Rafael da Silva / Banca: Mariangela Ribeiro Resende / Resumo: O uso da terapia antirretroviral (TARV) tem aumentado a sobrevida com melhora da qualidade de vida das pessoas vivendo com HIV/Aids (PVHA), o que também tem resultado em maior expectativa de vida. A infecção crônica pelo HIV e seu tratamento prolongado têm sido associados a diversas complicações ou eventos tardios, tais como, doenças metabólicas, cardiovasculares e renais, anormalidades na densidade mineral óssea (DMO) e osteoporose. Assim, o uso crônico da TARV tem demonstrado alta prevalência de deficiência de vitamina D, maior declínio da DMO e aumento do risco de fraturas de quadril, coluna vertebral e punhos, que têm sido relacionados principalmente ao uso de efavirenz, tenofovir e/ou inibidores de protease. Objetivos: estimar a prevalência e os fatores de risco das alterações ósseas e de fraturas, pela ferramenta FRAX, verificando a interferência da TARV sobre o nível sérico da vitamina D e na DMO em portadores do HIV. Casuística e métodos: foram estudadas 160 PVHA, com idades acima de 20 anos, de ambos os sexos, que atenderam aos critérios de inclusão para o estudo. Tratouse de estudo observacional realizado no Serviço de Ambulatórios Especializados de Infectologia "Domingos Alves Meira", Botucatu/SP. Foram incluídos pacientes adultos, com idade de 20 anos ou mais, em uso ou não de TARV e excluídos gestantes e mulheres menopausadas, além de indivíduos com diagnóstico de hipogonadismo. Prontuários médicos além de questionário específico foram utilizados para... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of antiretroviral therapy (ART) has increased survival and improved quality of life for people living with HIV/Aids (PLWH), this therapy has also resulted in longer life expectancy. Chronic HIV infection and its prolonged treatment have been associated with various complications or late events, such as metabolic, cardiovascular and renal diseases, abnormalities in bone mineral density (BMD), and osteoporosis. Thus, chronic usage of ART, has caused high prevalence of vitamin D deficiency, greater decline in BMD, and increased risk of hip, spine and fist fractures, that has been mainly related to use of efavirenz, tenofovir and/or protease inhibitors. Objectives: To estimate the prevalence and risk factors of bone alterations and fractures using the fracture risk assessment tool (FRAX), to verify the interference of ART on the serum level of vitamin D and in BMD among HIV patients. Casuistry and methods: 160 PLWH were studied, of both sexes, with ages over 20 years, who meet inclusion criteria for the study. This observational study was performed at the Domingos Alves Meira Department of Specialized Ambulatory Infectology (SAEI-DAM) - Botucatu/SP/Brazil. The study included adult patients, aged 20 years or older, in regular use of ART or not; pregnant, menopausal women and individuals who had been diagnosed with hypogonadism were excluded. Medical records and a specific questionnaire were used to obtain demographic data, information on life habits, family and individual histories of bone fractures and antiretroviral uses. Serum dosages were measured, with chemiluminescence for vitamin D and parathyroid hormone and dry chemistry for calcium, phosphorus and alkaline phosphatase, CD4+ T lymphocyte counts were made using flow cytometry, HIV viral load determinations were taken using real-time PCR and sandwich enzyme linked immunosorbent assay (ELISA Kit Elabscience) was used for a ... (Complete abstract click electronic access below) / Doutor
26

Uso do decanoato de nandrolona no tratamento da não união óssea em fraturas do rádio - estudo experimental em coelhos (oryctolagus cuniculus) /

Dissenha, Adrielly January 2019 (has links)
Orientador: Bruno Watanabe Minto / Resumo: O objetivo da pesquisa foi avaliar a eficácia do Decanoato de Nandrolona (DN) em fraturas do rádio após indução da não união óssea por defeito segmentar. Foram utilizados 47 coelhos, da raça Nova Zelândia Branco, com peso médio de 3,8 kg, divididos aleatoriamente em grupos de 8 animais. Os grupos Controle Machos (GCM) e Controle Fêmeas (GCF) foram submetidos à eutanásia aos 45 dias, os grupos Nandrolona Machos (GNM) e Nandrolona Fêmeas (GNF) tratados com aplicações semanais de DN na dose de 10mg/kg, via intramuscular (IM) durante 4 semanas. Os Grupos Placebo Machos (GPM) e Grupo Placebo Fêmeas (GPF), tratados com aplicações semanais de NaCl 0,9% (IM), durante o mesmo período. Foi realizado exame radiográfico após a cirurgia e aos 15, 30, 45, 60, 75 e 90 dias. Os animais dos grupos GNM, GNF, GPM e GPF foram submetidos à eutanásia aos 90 dias. Realizou-se exame de densitometria óssea do rádio dissecado após a eutanásia em todos os grupos, bem como análise histológica. Para as variáveis não-paramétricas utilizou-se o teste de Kruskal-Wallis. Para as variáveis paramétricas foi utilizado o teste Shapiro-Wilk, ambos a 5% de significância. Radiograficamente, os grupos tratados com DN apresentaram média de escore superior aos demais grupos na formação de calo ósseo. Na análise densitométrica, também foi observada uma melhora significativa ao parâmetro de composição mineral óssea (BMC) nos grupos GNM e GNF. Os machos apresentaram maiores médias para os parâmetros conteúdo mineral ósse... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
27

Caracterização miofuncional clínica e eletromiográfica de pacientes adultos com trauma de face / Oral-motor and electromyographic caracterization of patients submitted to open and closed reductions for facial fractures

Silva, Amanda Pagliotto da 03 December 2015 (has links)
Objetivo: realizar a caracterização do sistema miofuncional orofacial de indivíduos adultos com fraturas de face, que foram submetidos à procedimentos cirúrgicos distintos para a correção das fraturas (redução aberta e fechada). Métodos: 57 participantes divididos em três grupos: G1- composto por 19 indivíduos submetidos a redução aberta de pelo menos uma das fraturas faciais; G2- composto por 19 indivíduos submetidos a redução fechada da fratura; GC - 19 indivíduos voluntários saudáveis, sem alterações no sistema miofuncional orofacial. Todos os participantes foram submetidos à avaliação que consistiu na aplicação de um protocolo clínico para a avaliação da motricidade orofacial, a amplitude dos movimentos mandibulares e a avaliação da musculatura mastigatória por meio da eletromiografia de superfície (EMGs). Resultados: os resultados indicaram que para avaliação clínica da motricidade orofacial, ambos os grupos com fratura de face se diferenciaram do grupo controle, apresentando prejuízo na mobilidade dos órgãos fonoarticulatórios e nas funções de mastigação e deglutição. Os grupos com fratura de face não se diferenciaram neste item da avaliação. Quanto às medidas de amplitude mandibular, os grupos com fratura de face também se diferenciaram do grupo controle, apresentando maior restrição da mobilidade mandibular. Nesta etapa da avaliação, o grupo submetido à redução fechada da fratura apresentou maior amplitude de movimentos, se comparado ao grupo submetido à redução aberta da mesma, principalmente para a medida de abertura oral máxima. Na avaliação eletromiográfica dos músculos mastigatórios, o grupo submetido à redução aberta da fratura apresentou menor ativação muscular se comparado aos demais grupos. Ambos os grupos com fraturas de face se diferenciaram significantemente do grupo controle quando considerado o índice de assimetria do músculo masseter, apresentando funcionamento muscular mais assimétrico na tarefa de máxima intercuspidação dentária. Conclusão: Os pacientes com trauma de face apresentam alterações significativas em postura, mobilidade, funções orofaciais, amplitude mandibular e na atividade eletromiográfica. O tipo de tratamento médico não influenciou os resultados da funcionalidade muscular no período de até seis meses após a correção da fratura / Purpose: to characterize the oral-motor sytem of adults with facial factures, comparing the performance of individuals submitted to open and closed surgical treatment. Methods: 57 adults divided into three groups: G1 - 19 individuals submitted to open surgery for the correction of at least one of the facial fractures; G2 - 19 individuals submitted to closed surgery for the correction of facial fractures; GC - 19 voluntary healthy individuals, with no alterations of the orofacial myofunctional system. All participants underwent the same assessment: clinical assessment of the orofacial myofunctional system; evaluation of the mandibular range of movements; and surface electromyography (sEMG) of the masticatory muscles. Results: the results indicated that both groups with facial fractures presented significant differences when compared to the control group, in terms of the mobility of the oral-motor organs, mastication and swallowing. However, the groups with facial fractures did not differ in performance. Regarding the measurements obtained for the mandibular movements, both groups with facial fractures presented significant differences when compared to the control group, indicating greater restrictions in mandibular movements. The group submitted to closed surgery presented better range of movements when compared to the group submitted to open surgery, especially when considering the measurement of maximal mandibular opening. When analyzing the results of the sEMG, the group submitted to open surgery presented lower muscle activation when compared to the other two groups. Both groups with facial fractures differed significantly from the control group when considering the index of asymmetry for the masseter muscle, presenting a more asymmetrical muscle function during the task of maximum voluntary teeth clenching. Conclusion: Patients with facial trauma present significant deficits in posture, mobility and function of the oral motor system. The type of medical treatment did not have an influence on the results of muscle function during the first six months after fracture reduction
28

Caracterização miofuncional clínica e eletromiográfica de pacientes adultos com trauma de face / Oral-motor and electromyographic caracterization of patients submitted to open and closed reductions for facial fractures

Amanda Pagliotto da Silva 03 December 2015 (has links)
Objetivo: realizar a caracterização do sistema miofuncional orofacial de indivíduos adultos com fraturas de face, que foram submetidos à procedimentos cirúrgicos distintos para a correção das fraturas (redução aberta e fechada). Métodos: 57 participantes divididos em três grupos: G1- composto por 19 indivíduos submetidos a redução aberta de pelo menos uma das fraturas faciais; G2- composto por 19 indivíduos submetidos a redução fechada da fratura; GC - 19 indivíduos voluntários saudáveis, sem alterações no sistema miofuncional orofacial. Todos os participantes foram submetidos à avaliação que consistiu na aplicação de um protocolo clínico para a avaliação da motricidade orofacial, a amplitude dos movimentos mandibulares e a avaliação da musculatura mastigatória por meio da eletromiografia de superfície (EMGs). Resultados: os resultados indicaram que para avaliação clínica da motricidade orofacial, ambos os grupos com fratura de face se diferenciaram do grupo controle, apresentando prejuízo na mobilidade dos órgãos fonoarticulatórios e nas funções de mastigação e deglutição. Os grupos com fratura de face não se diferenciaram neste item da avaliação. Quanto às medidas de amplitude mandibular, os grupos com fratura de face também se diferenciaram do grupo controle, apresentando maior restrição da mobilidade mandibular. Nesta etapa da avaliação, o grupo submetido à redução fechada da fratura apresentou maior amplitude de movimentos, se comparado ao grupo submetido à redução aberta da mesma, principalmente para a medida de abertura oral máxima. Na avaliação eletromiográfica dos músculos mastigatórios, o grupo submetido à redução aberta da fratura apresentou menor ativação muscular se comparado aos demais grupos. Ambos os grupos com fraturas de face se diferenciaram significantemente do grupo controle quando considerado o índice de assimetria do músculo masseter, apresentando funcionamento muscular mais assimétrico na tarefa de máxima intercuspidação dentária. Conclusão: Os pacientes com trauma de face apresentam alterações significativas em postura, mobilidade, funções orofaciais, amplitude mandibular e na atividade eletromiográfica. O tipo de tratamento médico não influenciou os resultados da funcionalidade muscular no período de até seis meses após a correção da fratura / Purpose: to characterize the oral-motor sytem of adults with facial factures, comparing the performance of individuals submitted to open and closed surgical treatment. Methods: 57 adults divided into three groups: G1 - 19 individuals submitted to open surgery for the correction of at least one of the facial fractures; G2 - 19 individuals submitted to closed surgery for the correction of facial fractures; GC - 19 voluntary healthy individuals, with no alterations of the orofacial myofunctional system. All participants underwent the same assessment: clinical assessment of the orofacial myofunctional system; evaluation of the mandibular range of movements; and surface electromyography (sEMG) of the masticatory muscles. Results: the results indicated that both groups with facial fractures presented significant differences when compared to the control group, in terms of the mobility of the oral-motor organs, mastication and swallowing. However, the groups with facial fractures did not differ in performance. Regarding the measurements obtained for the mandibular movements, both groups with facial fractures presented significant differences when compared to the control group, indicating greater restrictions in mandibular movements. The group submitted to closed surgery presented better range of movements when compared to the group submitted to open surgery, especially when considering the measurement of maximal mandibular opening. When analyzing the results of the sEMG, the group submitted to open surgery presented lower muscle activation when compared to the other two groups. Both groups with facial fractures differed significantly from the control group when considering the index of asymmetry for the masseter muscle, presenting a more asymmetrical muscle function during the task of maximum voluntary teeth clenching. Conclusion: Patients with facial trauma present significant deficits in posture, mobility and function of the oral motor system. The type of medical treatment did not have an influence on the results of muscle function during the first six months after fracture reduction
29

Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis / Comparative study of osteosynthesis of ankle with conventional and bioabsorbable implants

Gaiarsa, Guilherme Pelosini 06 March 2013 (has links)
O padrão ouro no tratamento cirúrgico das fraturas de tornozelo são as sínteses metálicas, sejam de titânio ou aço. Os implantes bioabsorvíveis foram desenvolvidos para evitar o efeito do stress shielding, ou escudo de carga, e a retirada de material de síntese. O uso de materiais absorvíveis é bem documentado, e com bons resultados em grande número de fraturas craniofaciais. O objetivo deste estudo foi comparar os resultados funcionais de fraturas de tornozelo tratadas com placas metálicas e absorvíveis. Os pacientes foram randomizados e seguidos de forma prospectiva em dois grupos, metálico e absorvível. No período pós operatório imediato os pacientes foram imobilizados com tala gessada por uma semana, substituída por órtese removível por mais 4 semanas. Carga parcial foi autorizada com 3 semanas, e carga total com 6 semanas. Dezenove pacientes foram seguidos por nove meses, e avaliados radiográfica e funcionalmente aos 6 e 9 meses. Todos consolidaram entre 8 e 12 semanas. A recuperação funcional foi similar nos dois grupos. Aos 6 meses, três pacientes no grupo metálico queixaram-se de problemas locais, e tiveram seus implantes removidos. Um paciente do grupo absorvível teve uma deiscência da sutura, tratado com boa evolução. Aos 9 meses foi aplicado o escore da AOFAS para todos os pacientes. Os resultados funcionais foram semelhantes nos dois grupos, após a retirada de implante de três pacientes no grupo metálico. Os implantes absorvíveis permitiram resultados clínicos e funcionais semelhantes aos metálicos em fraturas de tornozelo / The current gold standard fixation system for surgical ankle fractures are the metallic implants, steel or titanium made. Resorbable implants have been developed to avoid stress shielding and a new surgery for implant removal, common with metal implants. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures, with good results. The purpose of this study was to compare the outcome of ankle fractures using biodegradable and metal plates. Patients were randomly and prospectively treated with resorbable or metal fixation system. Post-operatively, the ankle was immobilized with a plaster cast for 1 week, removable cast for other 4 weeks. Half and full weight bearing were allowed at weeks 3 and 6. nineteen patients were followed for 9 months. Functional recovery was similar in both groups at 6 and 9 months, three patients in metal group complained implant-related problems, and had their implants removed, and one in resorbable had an acute dehiscence, solved with surgical debridement and closure. At 6 and 9 months, the AOFAS score was applied for all patients. The functional results were similar in both groups. Implant removal was necessary in three patients from the metallic group. The resorbable plate provided qualitatively similar fracture healing results as the metal plate
30

Estudo comparativo entre as osteossínteses de tornozelo com implantes convencionais e bioabsorvíveis / Comparative study of osteosynthesis of ankle with conventional and bioabsorbable implants

Guilherme Pelosini Gaiarsa 06 March 2013 (has links)
O padrão ouro no tratamento cirúrgico das fraturas de tornozelo são as sínteses metálicas, sejam de titânio ou aço. Os implantes bioabsorvíveis foram desenvolvidos para evitar o efeito do stress shielding, ou escudo de carga, e a retirada de material de síntese. O uso de materiais absorvíveis é bem documentado, e com bons resultados em grande número de fraturas craniofaciais. O objetivo deste estudo foi comparar os resultados funcionais de fraturas de tornozelo tratadas com placas metálicas e absorvíveis. Os pacientes foram randomizados e seguidos de forma prospectiva em dois grupos, metálico e absorvível. No período pós operatório imediato os pacientes foram imobilizados com tala gessada por uma semana, substituída por órtese removível por mais 4 semanas. Carga parcial foi autorizada com 3 semanas, e carga total com 6 semanas. Dezenove pacientes foram seguidos por nove meses, e avaliados radiográfica e funcionalmente aos 6 e 9 meses. Todos consolidaram entre 8 e 12 semanas. A recuperação funcional foi similar nos dois grupos. Aos 6 meses, três pacientes no grupo metálico queixaram-se de problemas locais, e tiveram seus implantes removidos. Um paciente do grupo absorvível teve uma deiscência da sutura, tratado com boa evolução. Aos 9 meses foi aplicado o escore da AOFAS para todos os pacientes. Os resultados funcionais foram semelhantes nos dois grupos, após a retirada de implante de três pacientes no grupo metálico. Os implantes absorvíveis permitiram resultados clínicos e funcionais semelhantes aos metálicos em fraturas de tornozelo / The current gold standard fixation system for surgical ankle fractures are the metallic implants, steel or titanium made. Resorbable implants have been developed to avoid stress shielding and a new surgery for implant removal, common with metal implants. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures, with good results. The purpose of this study was to compare the outcome of ankle fractures using biodegradable and metal plates. Patients were randomly and prospectively treated with resorbable or metal fixation system. Post-operatively, the ankle was immobilized with a plaster cast for 1 week, removable cast for other 4 weeks. Half and full weight bearing were allowed at weeks 3 and 6. nineteen patients were followed for 9 months. Functional recovery was similar in both groups at 6 and 9 months, three patients in metal group complained implant-related problems, and had their implants removed, and one in resorbable had an acute dehiscence, solved with surgical debridement and closure. At 6 and 9 months, the AOFAS score was applied for all patients. The functional results were similar in both groups. Implant removal was necessary in three patients from the metallic group. The resorbable plate provided qualitatively similar fracture healing results as the metal plate

Page generated in 0.0421 seconds