• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 21
  • 5
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 107
  • 55
  • 52
  • 18
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise metabolômica e histomorfométrica do fígado de ratas adultas em modelo experimental da síndrome dos ovários policísticos induzida por exposição neonatal a esteroides sexuais / Metabolomic and histomorphometric analysis of the liver of rat models of polycystic ovary syndrome induced by neonatal exposure to sex steroids.

Anzai, Alvaro 11 August 2015 (has links)
A síndrome dos ovários policísticos (SOP) é um distúrbio endócrino complexo, associado a resistência insulínica, hiperinsulinemia, obesidade, acúmulo de gordura visceral e dislipidemia. Essas alterações podem levar a aumento de risco de doenças como \"diabetes mellitus\", doenças cardiovasculares, esteatose hepática ou até mesmo esteato-hepatite. Em ratas, o excesso de androgênios ou estrogênios no período neonatal induz a alterações metabólicas e reprodutivas similares às observadas na SOP em humanos. O objetivo deste estudo é analisar os efeitos da exposição neonatal à testosterona e ao estrogênio no fígado de ratas adultas. Para isso foram utilizadas 30 ratas, divididas em três grupos de 10 animais cada. Foi administrada por via subcutânea, entre 1 e 3 dias de vida, uma única dose dos seguintes compostos: 0,1 mL de óleo de oliva (veículo) - grupo Controle (n=10); propionato de testosterona (1,25 mg/0,1mL de veículo) - grupo Testosterona (n=10); benzoato de estradiol (0,5 mg/0,1mL de veículo) - grupo Estradiol (n=10), de acordo com o grupo a que pertenciam. Após cerca de 90 dias, os animais foram sacrificados, sendo retirados fragmentos do fígado que foram preparados para análise da metabolômica e da histomorfologia. Histologicamente, o fígado dos animais do grupo testosterona apresentaram maior infiltração gordurosa e infiltrado inflamatório; e do grupo estradiol apresentou hepatócitos binucleados, além do aumento do volume nuclear. Houve, no grupo testosterona modificações no perfil metabolômico ligadas a maior resistência à insulia e maior risco para diabete. O grupo exposto ao estrogênio apresentou alterações relacionadas ao metabolismo e síntese de lipídeos. Nossos resultados sugerem que os riscos metabólicos associados à SOP podem ter origem e mecanismos diferentes / Polycystic ovary syndrome (PCOS) is a complex endocrine disorder associated with insulin resistance, hyperinsulinemia, central obesity, accumulation of visceral fat and dyslipidemia. Those changes can lead to increased risk of diseases such as diabetes mellitus, cardiovascular disease, nonalcoholic fat liver disease or even nonalcoholic steatohepatitis. In rats, the excess of androgens or estrogens in the neonatal period leads to metabolic and reproductive alterations similar to those observed in SOP in humans. The objective of this study is to analyze the effects of exposure to neonatal testosterone and estrogen in the liver of adult rats. For this we used 30 female rats, sorted into three groups of 10 animals each. It was administered subcutaneously between 1 and 3 days of age a single dose of the following compounds: 0.1 mL olive oil (vehicle) - Control Group (n = 10); testosterone propionate (1.25 mg / 0.1 mL vehicle) - Testosterone (n = 10); estradiol benzoate (0.5 mg / 0.1 mL vehicle) - Estradiol group (n = 10). After 90 days, the animals were sacrificed, and the liver removed fragments were prepared for analysis of metabolomics and histomorphometry. Histologically, the testosterone group displayed greater fat deposition and higher degree of inflammatory infiltration. The estradiol group had binucleate hepatocytes and increased nuclear volume. Testosterone group showed changes in the metabolomic profile linked to increased insulin resistance and increased risk for diabetes mellitus. The group exposed to estrogen showed changes related to metabolism and synthesis of lipids. Our results indicate that the metabolic risks associated with PCOS may have origin and different mechanisms
72

Fotobiomodulação comparativa entre o laser e LED de baixa intensidade na angiogênese de feridas cutâneas de ratos / Comparative fotobiomodulation between the LED and low intensity laser in the angiogenisis of skin wounds in rats

Corazza, Adalberto Vieira 12 December 2005 (has links)
Os diodos emissores de luz – Light Emitting Diodes – (LEDs) são uma fonte de luz que estão sendo introduzidas comercialmente, mas com discreta base científica nesta modalidade fototerapêutica. O presente estudo comparou os efeitos angiogênicos da luz laser coerente e colimada à luz LED ausente de coerência e colimação em feridas induzidas em ratos, com fluências diferentes. O modelo experimental consistia da indução de uma ferida circular no quadríceps de 120 ratos, utilizando um “punch" com 15 mm de diâmetro. Os animais foram divididos aleatoriamente em 5 grupos: laser (660 nm) e LED (635 nm), sendo cada um ajustado a 5 J/'CM POT.2' e 20 J/'CM POT.2', além do controle. Após 6 horas da indução das feridas, os grupos tratados recebiam aplicação pontual de contato, e irradiados a cada 24 horas. A angiogênese foi analisada por meio da histomorfometria (H.E), e a contração das feridas pelo software de planimetria, sendo estudados os resultados no 3º, 7º, 14º e 21º dias pós-lesão. Os achados da análise histológica no 3º dia foram determinantes para induzir uma grande eficiência na proliferação de vasos sanguíneos dos grupos tratados em relação ao controle, demonstrando uma taxa próxima da constante no 7º dia, e com discreto aumento no 14º dia, porém com destaque para a tecnologia LED a 5 J/'CM POT.2' (p '< OU =' 0,05). No 21º dia, os grupos fototratados com fluência de 5 J/'CM POT.2' apresentavam valores estatísticos com maior eficiência na angiogênese quando comparados com o grupo laser a 20 J/'CM POT.2, sugerindo que fluências elevadas podem induzir um processo do tipo saturação. Não ocorreu diferença da neovascularização no centro e nas margens da ferida (p '< OU =' 0,05), sugerindo que ocorria uma fotobiomodulação de toda a lesão, favorecendo o crescimento homogêneo dos vasos sanguíneos. Tanto o laser quanto o LED não apresentaram resultados significativos na redução da área das feridas. As fototerapias a laser e LED de baixa intensidade sugeriram que a coerência e a colimação não eram fatores decisivos para induzir alterações nas funções celulares, e sim a banda de absorção do espectro eletromagnético. Ambas as fontes de luz vermelha ajustadas a fluências de 5 J/'CM POT.2' podem demonstrar resultados expressivos no estímulo angiogênico em pele lesada / The light emitting diodes (LEDs) are a source of light that have been commercially introduced, but still with a lack in its scientific basis in this phototherapeutic modality. The present study compared the angiogenics effects of the laser and LED illumination in induced wounds in rat, with fluencies different. The experimental model consisted of the induction of a circular wound on the quadriceps of 120 rats, using a “punch" with 15 mm diameter. Animals were divided randomyzed in 5 groups: laser and LED each device with a dosage of 5 J/'CM POT.2' and 20 J/'CM POT.2', and control. After 6 hours of the induction of the wounds, the treated groups received contact of punctual application, and irradiated every 24 hours. The angiogenesis was studied through the histomorphometric (H.E) and the wounds contraction was photographed and analyzed in the planimetrical software in the 3rd, 7th, 14th and 21st lesion induced days. The discoveries of the histological analysis in the 3rd day revealed larger efficiency in the proliferation of the blood vessels in all irradiated groups in comparison to controls, being a rate near of the constant in the 7th day, following to discreet improves in the 14th, even so with prominence for the LED with 5 J/'CM POT.2'. In the 21st day, the groups phototreatment with fluence of 5 J/'CM POT.2' showed similar statistically values in the larger efficiency in the angiogenesis, when to compare to laser with 20 J/'CM POT.2', suggesting high fluencies can induced a saturation process. The average of the area reduction of the wound didn't present similar statistician values of the treated groups in relation to the control (p '< OU =' 0,05). The phototherapeutic laser and LEDs of low intensity they suggested that the coherence and the collimation were not decisive factors to induce alterations in the cellular functions, but the band of the spectrum electromagnetic. The both red source of light agreements to fluencies of the 5 J/'CM POT.2', they can demonstrate expressive results in the incentive ulcerated skin angiogenic
73

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Dantas, Carolina Delmondes Freitas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
74

Avaliação da qualidade óssea da tíbia de ratas submetidas à hipoatividade através da suspensão pela cauda e tratadas com exercícios de natação / Assessment of the tibia bone quality in rats subjected to hypoactivity by tail suspension and treated with swimming exercises

Silva, Adriana Valadares da 21 February 2014 (has links)
O osso requer que alguns de seus elementos detectem estímulos mecânicos e os transformem em sinais celulares adequados para que o tecido ósseo possa manter a eutrofia e adaptar-se às solicitações mecânicas a que é submetido. Assim, a estrutura óssea pode torna-se mais resistente quando a demanda mecânica aumenta e, da mesma forma, menos resistente em condições de hipoatividade como imobilizações, sequelas motoras, repouso prolongado ou em ambientes de microgravidade como as experimentadas por astronautas. Dessa interação podem resultar ossos com massa diminuída, o que caracteriza situações de osteopenia ou osteoporose. Uma das indicações do exercício de natação é estimular e manter o trofismo do tecido ósseo. No entanto, a relação entre natação e qualidade óssea em pessoas com osteopenia, não foi suficientemente estudada de forma a embasar recomendações clínicas. Assim, o objetivo desta pesquisa foi investigar a eficácia da natação na recuperação da qualidade óssea avaliada em tíbias de ratas com osteopenia induzida por suspensão dos membros posteriores. Foram utilizadas 50 ratas da raça Wistar divididas em cinco grupos experimentais (n=10/grupo); dois controles e três experimentais. Houve um grupo suspenso pela cauda durante 21 dias consecutivos (S) e seu controle que permaneceu em gaiolas comuns pelo mesmo período (CI). No grupo suspenso e treinado os animais permaneceram em suspensão durante 21 dias, e depois foram submetidos a 20 sessões de natação (ST). No grupo suspenso não treinado os animais foram suspensos por 21 dias e soltos em gaiolas comuns por 30 dias (SNT). No grupo controle II as ratas foram observadas em gaiolas comuns por 51 dias, sem intervenção (CII). A avaliação da qualidade óssea foi feita pela densitometria (DXA) e ensaio mecânico realizados na tíbia direita e histomorfometria da região metafisária proximal da tíbia esquerda. Para análise estatística todos os valores foram considerados diferentes significativamente em p<0,05. Os ensaios mecânicos mostraram que, para o grupo S os valores de força máxima (-14,03%, p=0,0003), rigidez (-21,68%, p=0,0055), DMO (-17,62%, p=0,019) e percentual de osso trabecular (-57,2%, p=0,0001), diminuíram significativamente em comparação com o grupo CI. A comparação das propriedades mecânicas simultâneas entre os grupos avaliados após 51 dias (STxCIIxSNT) mostrou diferença estatística significante entre os grupos para força máxima de (p=0,0014), rigidez (p=0,0010), DMO (p= 0,0095) e percentual de osso trabecular (p<0,0001). O grupo ST apresentou aumento significativo na força máxima (+10,23%, p<0,05), rigidez (+21,91%, p<0,001), DMO (+9,46%, p<0,05) e percentual de osso trabecular (+48,82%, p<0,001) em comparação com o grupo SNT. Na comparação dos grupos SNT e CII também houve diminuição significativa (-14,4%, p<0,05) para força máxima, rigidez (-25,21%, p<0,005), DMO (-13,34%, p<0,05) e percentual de osso trabecular (-52,06%, p<0,001). Finalmente, a comparação entre os grupos ST e CII não apresentou diferença estatística significante (p>0,05) para os valores de força máxima, rigidez, DMO e percentual de osso trabecular. Em relação à análise histológica qualitativa o grupo S apresentou ossos com características histológicas condizentes com osteopenia, com trabéculas ósseas bem mais delgadas em quantidade muito menor tanto na epífise quanto na metáfise, quando comparado ao grupo CI. O grupo suspenso apresentou ainda, diminuição na espessura do tecido ósseo compacto e redução significativa na quantidade de tecido esponjoso em sua porção mais interna. A espessura do tecido ósseo compacto se mostrou similar nos diferentes grupos (ST, SNT e CII). Todavia, a espessura e a quantidade de trabéculas do osso esponjoso diferiram expressivamente nos diferentes grupos. O grupo ST apresentou uma aparente maior quantidade de trabéculas ósseas, bastante delgadas, ao passo que o grupo CII apresentou, comparativamente, uma menor quantidade de trabéculas bem mais espessas. Comparado a estes últimos, o grupo SNT apresentou uma menor quantidade de trabéculas com delgada espessura. Com a suspensão por três semanas os parâmetros mostraram que houve deterioração da qualidade óssea expressa pela diminuição da densidade mineral óssea, enfraquecimento mecânico do osso e perda de massa óssea trabecular. A quantidade de osso trabecular na região metafisária foi o parâmetro mais afetado pela hipoatividade, mas também o elemento que apresentou a resposta mais rápida para a atividade motora. A conclusão foi que a natação reverteu mais rapidamente a deterioração osteopênica causada pela hipoatividade, com recuperação completa da qualidade óssea. / The bone is able to detect mechanical stimuli and to transform them into cell response so that the bone tissue can maintain its health and to adapt to different mechanical demands (mechanotransduction). Thus, the bone structure become more resistant when the mechanical solicitations are increased and, conversely, less resistant when in hypoactivity conditions as occurring during immobilizations, in locomotor sequela, prolonged bed rest or in a microgravity environment as experienced by astronauts. In general, hypoactivity leads the bone to develop a decreased and deteriorated mass, thus characterizing conditions of osteopenia or osteoporosis. Thus, physical activity such as swimming is indicated as one of the factors that contribute to the bone health. However, the relation between swimming and bone quality in individuals with osteopenia has not been sufficiently studied to fully support clinical recommendations. So, the aim of this study was to investigate the effectiveness of swimming in recovering bone quality evaluated in osteopenic tibias of rats that spent three weeks in hindlimb suspension. Fifty Wistar rats were used and divided into five groups (n = 10/group); two control and three experimental groups. There was a group suspended by the tail for 21 consecutive days (S) and its control kept in regular cages for the same period (CI). In the suspended and trained group, animals were suspended for 21 consecutive days and then underwent a 20 swimming sessions (ST). In the suspended, not trained group, animals were suspended for 21 days and released in regular cages for 30 days (SNT). In the control group II rats were kept in regular cages for 51 days without intervention (CII). The bone quality was assessed by densitometry (BMD), bending mechanical testing and histomorphometry. Statistical significance was set at p<0.05. Mechanical tests showed that for the suspended group there was a decrease of the maximum force (-14.03%, p = 0.0003), stiffness (-21.68%, p = 0.0055), BMD (-17.62 %, p = 0.019) and the percentage of trabecular bone (-57.2%, p = 0.0001) in comparison with the control group. Comparison among the groups after 51 days (STxCIIxSNT) showed statistically significant differences between groups for maximum force (p = 0.0014), stiffness (p = 0.0010), BMD (p = 0. 0095) and the percentage of trabecular bone (p<0.0001). The suspended and trained group showed a significant increase in maximum force (+10.23%, p <0.05), stiffness (+21.91%, p<0.001), BMD (+9.46%, p<0.05) and the percentage of trabecular bone (+48.82%, p <0.001) compared to the suspended and not trained group. When the suspended but not trained group was compared to control CII, there was also a significant decrease (- 14.4%, p<0.05) for maximum force, stiffness (-25.21%, p<0.005), BMD (-13.34%, p<0.05) and the percentage of trabecular bone (-52.06%, p<0.001). Finally, the comparison between group suspended and trained ad its control and CII showed no statistically significant difference (p>0.05) for all the parameters. Considering the qualitative histological analysis, suspended group presented bones with histological characteristics consistent with osteopenia, with thinner trabecular bone and in much less quantity both in the epiphysis and in the metaphysis. The suspended and trained group had a higher quantity of trabecular bone, with thinner trabeculae, while the CII group showed a comparatively smaller amount of much thicker trabeculae. Compared to the latter, the suspended and not trained group had an apparent smaller amount of trabeculae with a thinner thickness. In conclusion, the three week suspension caused a marked deterioration of the tibia bone tissue that was completely reverted by swimming and partially reverted with spontaneous cage activities taking in consideration all the parameters analyzed.
75

Die Wirkung von systemisch appliziertem rekombinantem speziesspezifischem Wachstumshormon auf den Knochenumbau am Achsenskelett

Funk, Julia Franziska 27 October 2004 (has links)
Die Auswirkung der systemischen Applikation von 100µg/kg/KG rekombinantem speziesspezifischem Wachstumshormon (GH) über 26 Tage auf den Knochenumbau des Yucatan-Minischweins wurde an Wirbelkörpern, Beckenkämmen und Rippen histomorphometrisch untersucht. Der Einfluss der Distraktionsosteogenese auf die Mineralappositionsrate wurde ermittelt. 24 Tiere wurden an der linken Tibia osteotomiert, ein Fixateur externe wurde zur Distraktionsosteogenese von 2mm/d angelegt. 12 Tiere erhielten Wachstumshormon, 12 Placebo. Eine polychrome Fluoreszenzmarkierung wurde i.v. appliziert. Post mortem wurden Schnitte und Dünnschliffe der genannten Knochen angefertigt. Mittels Bildanalysesystem erfolgte die histomorphometrische Auswertung anhand der Parameter Knochendichte, Porosität, Trabekeldicke, Trabekelumbauparameter und Mineralappositionsrate (MAR). Signifikante Veränderungen durch Wachstumshormongabe konnten gezeigt werden. Unterschiede zwischen den Lokalisationen traten auf. So war die Knochendichte der GH-Tiere an Wirbelkörpern und Rippen signifikant geringer als in der Placebogruppe, kein signifikanter Unterschied zeigte sich am Beckenkamm. An allen 3 Lokalisationen war in der Wachstumshormongruppe eine signifikant erhöhte kortikale Porosität zu finden. Nur am Wirbelkörper waren die trabekuläre Knochendichte und die Trabekeldicke bei den GH-Tieren signifikant geringer als bei den Kontrolltieren. Die Knochenresorption war in der GH-Gruppe am Beckenkamm signifikant erhöht. Die Formation war bei den GH-Tieren sowohl iliakal als auch vertebral signifikant erhöht. Insgesamt ergab sich damit ein signifikant verminderter Anteil an ruhender Oberfläche bei den GH-Tieren. In ihrer Ausprägung waren diese Parameter zwischen Wirbel und Beckenkamm signifikant verschieden. Die MAR war in der GH-Gruppe signifikant höher als in der Placebogruppe, außerdem war sie während der Distraktionsphase signifikant höher als während der Konsolidierungsphase. Vergleicht man die Parameter mit Angaben aus der Literatur, kann bestätigt werden, dass die hier verwendeten Messmethoden geeignet sind, und dass das Yucatan-Minischwein ein geeignetes Modell zur Klärung von Fragestellungen der Knochenbiologie auch im Hinblick auf den Vergleich zum Menschen darstellt. / The effect of systemic application of 100 µg/kg recombinant species specific growth hormone (GH) on the bone remodelling of 24 Yucatan mini pigs for a duration of 26 days was evaluated on vertebral body, iliac crest, and rib. The influence of distraction osteogenesis on the mineral apposition rate (MAR) was examined. 24 animals were osteotomized at the left tibia and treated with an external fixator for distraction osteogenesis of 2 mm/d. 12 of them received GH, the others placebo. A sequential polychrome fluorescent labelling was applied. After sacrifice thin and ground sections were manufactured. Using an image analysis system, a histomorphometrical evaluation was performed by means of bone density, porosity, trabecular thickness, trabecular remodelling parameters, and mineral apposition rate (MAR). Significant changes after GH application were visible. Differences between the locations were found. The bone density of vertebrae and ribs of the treatment group was significantly lower than that of the placebo group, whereas no difference was seen in the iliac crest biopsies. All 3 locations showed a significantly higher cortical porosity in the GH group. The trabecular bone density and the trabecular thickness were significantly decreased only in the vertebral bodies of the treatment group. The bone resorption was significantly elevated in the iliac crests of the GH group. The bone formation was increased in the iliac crest as well as in the vertebrae of the GH treated animals. Therefore, the resting surface was significantly decreased in the GH group. The extent of these effects was significantly different between iliac crest and vertebral body. The MAR was significantly higher in the GH group and during distraction osteogenesis. Compared to results of other study groups these parameters validate the methods of measurement and show that the Yucatan mini pig is a suitable model for research concerning bone biology, especially concerning the comparison with human parameters.
76

Comparação das características clínicas, bioquímicas e da análise histomorfométrica de biópsias ósseas de pacientes com doença renal crônica em diálise com e sem fratura / Comparison of clinical, biochemical and histomorphometric analysis of bone biopsies in dialysis patients with and without fractures

Santos, Melissa Fernanda Pinheiro 06 July 2017 (has links)
INTRODUÇÃO: Os distúrbios minerais e ósseos (DMO) da doença renal crônica (DRC) estão associados ao aumento do risco de fratura, estudos relatam cerca de 3% de fraturas neste grupo de pacientes, e as mesmas ocorrem mais precocemente quando comparadas à população geral, ou seja, 16 e 13 anos antes para homens e mulheres, respectivamente. A melhora no tratamento do DMO ainda não impactou na diminuição das fraturas, assim a melhor compreensão da fisiopatologia das mesmas provavelmente contribuiria para novas abordagens terapêuticas. OBJETIVOS: avaliar informes de fraturas, de ossos longos, de um banco de biopsias ósseas de pacientes com DRC em hemodiálise, e comparar, as características clínicas, bioquímicas e os resultados da análise histomorfométrica do osso trabecular e cortical desses pacientes com o de outros sem fraturas, pareados para idade, sexo e tempo de hemodiálise. Avaliamos também, por imunohistoquimica, a expressão de proteínas envolvidas na formação (SOST) e na mineralização óssea (DMP1, MEPE) de ambos os grupos. MÉTODOS: dezessete pacientes com fratura e igual número de controles foram estudados. RESULTADOS: A prevalência de fraturas foi de 5,5 fraturas/1000 pacientes ano a maioria deles tinha menos de 60 anos e tempo em hemodiálise inferior a 10 anos. Quanto a analise dos dados bioquímicos somente os níveis de fósforo sérico foram significativamente mais baixos nos pacientes com fratura comparada aos controles. Os resultados da análise histomorfométrica revelaram que a totalidade dos pacientes com e sem fratura apresentava doença de alta remodelação e nos fraturados detectamos menor volume e espessura trabecular, maior superfície osteóide, menor superfície de reabsorção além de menor superfície mineralizante, taxa de formação e maior tempo de intervalo para mineralização óssea quando comparados aos controles. Não encontramos diferenças na análise da espessura e porosidade cortical entre os dois grupos e a expressão da DMP1 no osso cortical foi menor e da SOST no osso trabecular foi maior nos pacientes fraturados comparados aos controles além de se associarem com parâmetros estruturais, de formação, de reabsorção e de mineralização. CONCLUSÕES: No banco de informes de biópsias ósseas analisado, encontramos alta prevalência de pacientes com fratura. Os pacientes com e sem fratura apresentavam doença de alta remodelação, porém os fraturados apresentavam maior comprometimento da microarquitetura óssea assim como menor formação e maior defeito de mineralização quando comparados aos pacientes sem fratura. A expressão de proteínas ósseas envolvidas na formação e mineralização óssea se correlacionaram com parâmetros envolvidos na remodelação óssea / INTRODUCTION: Mineral and bone disorders (BMD) of chronic kidney disease (CKD) are associated with increased risk of fracture. Studies report about 3% of fractures in this group of patients, and these occur earlier than in the general population, namely 16 and 13 years earlier for men and women, respectively. Improvement in BMD treatment has not yet impacted reduction of fractures, therefore a better understanding of the pathophysiology of fractures would probably contribute to new therapeutic approaches. OBJECTIVES: evaluate report of long bone fractures from a bank of bone biopsies from patients with CKD on hemodialysis, and compare clinical and biochemical characteristics as well as the results of the histomorphometric analysis of trabecular and cortical bone of these patients with that of others without fractures, paired for age, gender, and time on hemodialysis. We also evaluated the expression of proteins involved in formation (SOST) and bone mineralization (DMP1, MEPE) of both groups by immunohistochemistry. METHODS: seventeen patients with fracture and an equal number of controls were studied. RESULTS: The prevalence of fractures was 6%, the majority of the patients were less than 60 years old, and the time on hemodialysis was less than 10 years. Regarding the analysis of the biochemical data, only serum phosphorus levels were significantly lower in patients with fracture compared to controls. Results of the histomorphometric analysis revealed that all the patients with and without fracture had high turnover disease, and in the fractured ones we detected a smaller trabecular volume and thickness, greater osteoid surface, and smaller surface of resorption in addition to smaller mineralizing surface, formation rate and longer time interval for bone mineralization when compared to controls. We did not find differences in the analysis of thickness and cortical porosity between the two groups; the DMP1 expression in the cortical bone was smaller and the SOST in the trabecular bone was higher in the fractured patients compared to that of controls, besides being associated with structural parameters, formation, reabsorption and mineralization. CONCLUSIONS: In the database of analyzed bone biopsies, we found low prevalence of patients with fracture. Patients with and without fracture had high turnover disease, but the fractured ones presented more impaired bone microarchitecture as well as lower formation and greater mineralization defect when compared to the patients without fracture. The expression of bone proteins involved in bone formation and mineralization correlated with parameters involved in bone remodeling
77

Quantificação do potencial osteogênico in vivo do osso autógeno + células osteoblásticas carreadas por uma biocerâmica composta de hidroxiapatita e fosfato tricálcio-&beta;: Estudo qualitativo e quantitativo em microscopia de luz e eletrônica de varredura / Quantification of the osteogenic potential in vivo of autogenous bone + osteoblastic cells carried by a bioceramic consisting of hydroxyapatite and &beta;-tricalcium phosphate: A qualitative and quantitative study by light and scanning electron microscopy

Rander Moreira Macedo 21 June 2013 (has links)
Durante e após o processo de reparo alveolar pós-extração, ocorre certa remodelação óssea com reduções dimensionais deste tecido podendo comprometer a terapia em implantodontia. A fim de preservar/reconstruir tal tecido, vários métodos são propostos usando diferentes tipos de biomateriais e técnicas, os quais demonstram capacidade em formar osso. O osso autógeno ainda é considerado a referência padrão como enxerto ósseo, devido ao seu potencial osteogênico, osteoindutor e osteocondutor, mas morbidade relativa a este é conhecida. Por isso algumas biocerâmicas têm sido utilizadas, pois são sintéticas, biocompatíveis e com boas propriedades osteopreenchedoras, mas com baixa osteogenicidade. A engenharia tecidual óssea constituída de células tronco mesenquimais diferenciadas em osteoblastos é uma estratégia para o fornecimento adicional celular ao defeito ósseo em reconstrução. O objetivo deste estudo foi qualificar e quantificar a reparação óssea após o enxerto de uma associação de osso autógeno e células osteoblásticas carreadas por uma biocerâmica em defeitos ósseos produzidos pela extração dentária. Os animais foram divididos de acordo com o material implantado no alvéolo dentário pós-extração em: Controle (c), osso autógeno (oa), células osteoblásticas (co), biocerâmica (bc), osso autógeno + células osteoblásticas (oa+co), osso autógeno + biocerâmica (oa+bc), biocerâmica + células osteoblásticas (bc+co), e biocerâmica + células osteoblásticas + osso autógeno (bc+co+oa). O sacrifício ocorreu aos 7, 21 e 42 dias pós-cirurgia e as amostras teciduais foram processadas para análise em microscopia de luz e eletrônica de varredura. Através de um sistema de análise de imagens foi avaliado a qualidade dos biomateriais implantados e o volume de osso, biocerâmica, conjuntivo e coágulo no defeito ósseo. Os resultados qualitativos revelaram que a biocerâmica implantada foi biocompatível e estava intimamente unida ao osso. O uso das células osteoblásticas, do osso autógeno ou da biocerâmica não desencadearam reações imunogênicas, de corpo estranho ou formação tumoral. Histometricamente as células osteoblásticas carreadas pela biocerâmica mostraram um preenchimento ósseo 19,0% maior do que quando não carreadas. A associação biocerâmica/células osteoblásticas + osso autógeno promoveu, aos 7 dias, uma deposição óssea 56,52% mais efetiva nos arredores do biomaterial do que a enxertia da biocerâmica isoladamente (1%). Conclui-se que a biocerâmica em questão pode ser um viável carreador às células osteoblásticas a serem enxertadas em sítios de reconstrução óssea, e que este composto híbrido recebe um efeito sinérgico quando da associação ao osso autógeno, sendo capaz desta forma de acelerar o processo de neoformação óssea principalmente nos períodos iniciais da reparação alveolar. / During and after the process of alveolar repair post-extraction, bone remodeling occurs with certain dimensional reductions of this tissue that can compromise the therapy in implantology. In order to preserve/reconstruct such tissue, various methods are proposed using different types of biomaterials and techniques which demonstrate the capacity to form bone. The autogenous bone is still regarded as the gold standard bone graft, due to their osteogenic, osteoinductive and osteoconductive potential, but morbidity is known about it. Therefore some bioceramics have been used, as they are synthetic, biocompatible and with good properties of bone fill, but with low osteogenic potential. The bone tissue engineering consists of mesenchymal stem cells differentiated into osteoblasts is a strategy for providing additional cell in the bone defect reconstruction. The aim of this study was to qualify and quantify bone healing after grafting of an association of autogenous bone and osteoblastic cells carried by a bioceramic in bone defects produced by tooth extraction. The animals were divided according to the implanted material in dental socket after extraction: Control (c), autogenous bone (ab), osteoblastic cells (oc), bioceramic (bc), autogenous bone + osteoblastic cells (ab+oc), autogenous bone + bioceramic (ab+bc), bioceramic + osteoblastic cells (bc+oc), and bioceramic + autogenous bone + osteoblastic cells (bc+oc+ab). The animals were sacrificed at 7, 21 and 42 days post-surgery and tissue samples were processed for light microscopy and scanning electron microscopy. Through an image analysis system the quality of implanted biomaterials and the volume of bone, bioceramic, conjunctive tissue and blood clot was evaluated inside the bone defect. Qualitative results revealed that the grafted bioceramic was biocompatible and intimately bonded with the bone. The use of osteoblastic cells, autogenous bone or bioceramic didnt trigger immunogenic reactions, foreign body or tumor formation. Histometrically, the osteoblast cells carried by bioceramic showed a bone filling 19.0% higher than when not carried. The bioceramic/osteoblastic cells + autogenous bone association promoted, at 7 days, a bone deposition 56.52% more effective around the biomaterial than the grafting of bioceramic alone (1%). It was concluded that the bioceramic in question may be a viable carrier to osteoblastic cells to be grafted on sites of bone reconstruction, and this hybrid compound receives a synergistic effect when associated to autogenous bone, thus being able to accelerate the bone formation especially in the early periods of alveolar repair.
78

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Carolina Delmondes Freitas Dantas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
79

Estudo comparativo dos efeitos do ultra-som e do laser de baixa intensidade no reparo ósseo de tíbia de rato / Comparative study of ultra-sound and low intensity laser therapy effects on bone healing in rats tibia

Lirani, Ana Paula Rebucci 24 March 2004 (has links)
Vários estudos têm avaliado os efeitos do ultra-som e da radiação laser de baixa intensidade separadamente no reparo ósseo. No entanto, são escassas as comparações entre estas duas modalidades terapêuticas. Este estudo teve por objetivo avaliar e comparar, através de análise histomorfométrica e ensaio mecânico de flexão em três pontos, as conseqüências que estes agentes físicos podem trazer ao reparo do tecido ósseo em osteotomias transversais experimentais em tíbias de ratos. Foram utilizados 48 ratos com fratura cirúrgica unilateral parcial do terço superior de tíbia. Os animais foram divididos em três grupos de 16 animais. Em um grupo, o membro fraturado foi tratado com ultra-som pulsado de baixa intensidade (freqüência de 1,5 MHz, ciclo de trabalho 1:4, intensidade SATA 30 mW/centímetro quadrado) em sessões de 20 minutos, 5 vezes por semana, em 12 dias de tratamento. Em um segundo grupo, o membro fraturado foi tratado com laser As-Ga-Al (112,5 J/centímetro quadrado, 780 nm, 30 mW) em sessões de 2,5 minutos, 5 vezes por semana, em 12 dias de tratamento. O terceiro grupo serviu de controle, sendo submetido à mesma cirurgia na tíbia direita mas não recebeu qualquer tratamento. No ensaio mecânico, a carga no limite máximo suportada pelo grupo tratado com laser foi significantemente maior (p < 0,05) que os grupos tratado com ultra-som e controle. Na análise histomorfométrica, o grupo tratado com laser apresentou significância estatística quanto ao número e superfície de osteoblastos e volume e superfície de osteóide e o grupo ultra-som obteve significância para as superfícies de reabsorção e de osteoclastos. Pode-se concluir que o ultra-som acelerou o reparo ósseo (em relação ao grupo controle) por viabilizar mais rapidamente a fase de reabsorção, enquanto que a terapia laser foi capaz de acelerar ainda mais este processo por já promover predomínio de formação óssea no décimo nono dia pós-cirúrgico no modelo experimental utilizado neste estudo / Many studies have assessed the effects of ultra-sound and low intensity laser therapy separatedly in bone repair. However, the comparison between these two therapeutic modalities is rare. The objective of this study was to verify and compare, through histomorphometrical analysis and a three-point bending test, the consequences of these physical agents on bone healing in animals. 48 male Wistar rats were used with tibial bone partial osteotomy, divided into 3 groups of 16. In one group, rats had their fractured limb treated with GaAIAs laser (780 nm, 30 mW, 112,5 J/square contimeter) in 12 five times-a-week sections. In another group, rats were treated with low intensity pulsed ultra-sound (1,5 MHz, 30 mW/square centimeter) in 12 five times-a-week sections too. In a third group, animals were taken as control, being submitted to the same osteotomy but receiving no treatment. After 19 days the tibias were extracted and half of them were submitted to a three-point bending test and the other half to histomorphometric analysis. During the bending test, the maximum load at failure of the tibia in the laser group was significantly higher (p<0.05). Histomorphometry showed statistical significance in osteoblasts number and surface and osteoid volume and surface for the laser group, and eroded and osteoclasts surfaces for the ultra-sound group. Ultra-sound was able to enhance bone healing (compared to control group) by speeding up the reabsorption phase, while low intensity laser therapy could accelerate this process even more by promoting mostly new bone formation 19 days after osteotomy in this experimental model
80

Taxa de alimentação para juvenis de pirapitinga criados em hapas / Feeding rate of youth for pirapitinga created in hapas

Zarpellon, Idayana 19 October 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-03-10T18:32:43Z No. of bitstreams: 2 Dissertação - Idayana Zarpellon - 2015.pdf: 1299703 bytes, checksum: 695f80e09eb68cc4574a5e0bcd34a197 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-03-14T14:26:40Z (GMT) No. of bitstreams: 2 Dissertação - Idayana Zarpellon - 2015.pdf: 1299703 bytes, checksum: 695f80e09eb68cc4574a5e0bcd34a197 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-03-14T14:26:40Z (GMT). No. of bitstreams: 2 Dissertação - Idayana Zarpellon - 2015.pdf: 1299703 bytes, checksum: 695f80e09eb68cc4574a5e0bcd34a197 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-10-19 / This study was conducted in order to evaluate the effect of different feeding rates on growth performance, economic evaluation, morphometric characteristics and blood biochemistry of pirapitinga (Piaractusbrachypomus) in ponds during rearing. The experiment was conducted in the Fish Farming Sector of the Department of Animal Science School of Veterinary and Animal Science at UFG in the period from February to April, for 60 days. It was used 100 juveniles pirapitinga with an average weight of 328.81 ± 25.55 grams, randomly assigned in 20 hapas of 1 m³ installed in excavated tank of 200 m² in density of 05 juveniles / m³. The experimental design was randomized blocks, with five treatments, T1 0.7% of biomass; T2 1.4% of biomass; T3 2.1% of biomass; T4-2,8% of biomass; T5- 3.5% of biomass; with four replications, totaling 20 experimental units. Fish were fed with commercial feed containing 32% CP and grain size of 2-4 mm, twice a day, at 9 am and at 5 pm. The supply of feed was based on the percentage of biomass, so it was done a biometrics fortnightly from start to end of the experiment. The variables of productive performance were analyzed; economic evaluation; chemical composition of the carcass; blood chemistry ehistomorfometria gut: villi height. Data were subjected to analysis of polynomial regression and variance, and, in case of statistical differences, the average comparison test SNK (5%). The final individual weight and weight gain, showed a quadratic relation, in function of the increasing feed levels and their maximum points were checked feed rates de2,77% and 2.78% biomass per day, respectively. It was concluded that the feeding rate of 2.1% biomass per day resulted in a better performance and economic result and shorter ether extract to pirapitinga created during rearing in excavated tank. / Este trabalho foi desenvolvido com o intuito de avaliar o efeito de diferentes taxas de alimentação sobre o desempenho zootécnico, avaliação econômica, características morfométricas e bioquímica sanguínea da pirapitinga (Piaractus brachypomus) em tanques escavados durante a recria. O experimento foi conduzido no Setor de Piscicultura do Departamento de Zootecnia da Escola de Veterinária e Zootecnia da UFG no período de fevereiro a abril, com duração de 60 dias. Foram utilizados 100 juvenis de pirapitinga com peso médio de 328,81±25,55 gramas, distribuídos aleatoriamente em 20 hapas 1 m³ instaladas em tanque escavado de 200 m² na densidade de 05 juvenis/m³. O delineamento experimental utilizado foi blocos ao acaso, com cinco tratamentos, T1- 0,7% da biomassa; T2- 1,4% da biomassa; T3- 2,1% da biomassa; T4-2,8% da biomassa; T5- 3,5% da biomassa; com quatro repetições, totalizando 20 unidades experimentais. Os peixes foram alimentados com ração comercial contendo 32%PB e granulometria de 2-4 mm, duas vezes ao dia, às 9h e 17 h. O fornecimento de ração foi realizado com base na porcentagem da biomassa, por isso, foram realizadas biometrias quinzenais do início ao final do experimento. Foram analisadas as variáveis de desempenho produtivo; avaliação econômica; composição química da carcaça; bioquímica sanguínea e histomorfometria de intestino: altura de vilos. Os dados foram submetidos à análise de regressão polinomial e de variância, e, em caso de diferença estatística, ao teste de comparação de média SNK (5%). O peso final e ganho de peso individual, apresentaram relação quadrática, em função do aumento do nível de arraçoamento e seus pontos de máxima foram verificados com as taxas de alimentação de 2,77% e 2,78%, da biomassa ao dia, respectivamente. Conclui-se que a taxa de alimentação 2,1% da biomassa ao dia, proporcionou melhores desempenhos produtivos e econômicos e menor teor de extrato etéreo, para pirapitingas criadas durante a recria em tanque escavado.

Page generated in 0.0912 seconds