• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 64
  • 48
  • Tagged with
  • 195
  • 195
  • 145
  • 132
  • 128
  • 128
  • 54
  • 47
  • 47
  • 47
  • 46
  • 40
  • 30
  • 28
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Nanoparticules Chitosane-PEG-FA-ADN pour la thérapie génique non virale et application du gène de l’IL-1Ra dans un modèle expérimental d’arthrite rhumatoïde

Jreyssaty, Christian 04 1900 (has links)
La thérapie génique représente l'un des défis de la médecine des prochaines décennies dont la réussite dépend de la capacité d'acheminer l'ADN thérapeutique jusqu'à sa cible. Des structures non virales ont été envisagées, dont le chitosane, polymère cationique qui se combine facilement à l’ADN. Une fois le complexe formé, l’ADN est protégé des nucléases qui le dégradent. Le premier objectif de l'étude est de synthétiser et ensuite évaluer différentes nanoparticules de chitosane et choisir la mieux adaptée pour une efficacité de transfection sélective in vitro dans les cellules carcinomes épidermoïdes (KB). Le deuxième objectif de l'étude est d'examiner in vivo les effets protecteurs du gène de l'IL-1Ra (bloqueur naturel de la cytokine inflammatoire, l’Interleukine-1β) complexé aux nanoparticules de chitosane sélectionnées dans un modèle d'arthrite induite par un adjuvant (AIA) chez le rat. Les nanoparticules varient par le poids moléculaire du chitosane (5, 25 et 50 kDa), et la présence ou l’absence de l’acide folique (FA). Des mesures macroscopiques de l’inflammation seront évaluées ainsi que des mesures de concentrations de l’Interleukine-1β, Prostaglandine E2 et IL-1Ra humaine secrétés dans le sérum. Les nanoparticules Chitosane-ADN en présence de l’acide folique et avec du chitosane de poids moléculaire de 25 kDa, permettent une meilleure transfection in vitro. Les effets protecteurs des nanoparticules contenant le gène thérapeutique étaient évidents suite à la détection de l’IL-1Ra dans le sérum, la baisse d'expressions des facteurs inflammatoires, l’Interleukine-1 et la Prostaglandine-E2 ainsi que la diminution macroscopique de l’inflammation. Le but de cette étude est de développer notre méthode de thérapie génique non virale pour des applications cliniques pour traiter l’arthrite rhumatoïde et d’autres maladies humaines. / Considered to be one of the medical challenges of the coming decade, the success of gene therapy depends on the ability to deliver therapeutic DNA to target cells. Non-viral polymers, such as chitosan (Ch), a cationic polymer, can be easily combined with DNA. Once a complex is formed, DNA is protected from degradation by nucleases. The first objective of this study was to define the characteristics of the best-suited Ch nanoparticle for maximum selective transfection in human epidermoid carcinoma (KB) cells in vitro. Nanoparticles varied by the presence or absence of folic acid (FA) and Ch’s molecular weight (MW 5, 25 and 50 kDa). They were then selected and combined with interleukin-1 receptor antagonist (IL-1Ra) gene, a natural blocker of the inflammatory cytokine interleukin-1beta (IL-1β). The second objective was to inject these carriers by the hydrodynamic method in a rat model of adjuvant-induced arthritis and to evaluate the inhibitory effects of IL-1Ra against inflammation in vivo. Ch-DNA nanoparticles with FA and Ch25 demonstrated selective transfection and significantly increased it in KB cells in vitro. The inhibitory effects of IL-1Ra gene therapy in vivo were evident from lower expression levels of inflammatory factors (IL-1 and prostaglandin E2) and decreased macroscopic limb inflammation. The results also revealed the presence of human recombinant IL-1Ra protein in rat sera. Non-viral gene therapy with Ch-PEG-FA-DNA nanoparticles containing the IL-1Ra gene appears to significantly decrease inflammation in this experimental model of arthritis.
172

Conventional and Reciprocal Approaches to the Forward and Inverse Problems of Electroencephalography

Finke, Stefan 03 1900 (has links)
Le problème inverse en électroencéphalographie (EEG) est la localisation de sources de courant dans le cerveau utilisant les potentiels de surface sur le cuir chevelu générés par ces sources. Une solution inverse implique typiquement de multiples calculs de potentiels de surface sur le cuir chevelu, soit le problème direct en EEG. Pour résoudre le problème direct, des modèles sont requis à la fois pour la configuration de source sous-jacente, soit le modèle de source, et pour les tissues environnants, soit le modèle de la tête. Cette thèse traite deux approches bien distinctes pour la résolution du problème direct et inverse en EEG en utilisant la méthode des éléments de frontières (BEM): l’approche conventionnelle et l’approche réciproque. L’approche conventionnelle pour le problème direct comporte le calcul des potentiels de surface en partant de sources de courant dipolaires. D’un autre côté, l’approche réciproque détermine d’abord le champ électrique aux sites des sources dipolaires quand les électrodes de surfaces sont utilisées pour injecter et retirer un courant unitaire. Le produit scalaire de ce champ électrique avec les sources dipolaires donne ensuite les potentiels de surface. L’approche réciproque promet un nombre d’avantages par rapport à l’approche conventionnelle dont la possibilité d’augmenter la précision des potentiels de surface et de réduire les exigences informatiques pour les solutions inverses. Dans cette thèse, les équations BEM pour les approches conventionnelle et réciproque sont développées en utilisant une formulation courante, la méthode des résidus pondérés. La réalisation numérique des deux approches pour le problème direct est décrite pour un seul modèle de source dipolaire. Un modèle de tête de trois sphères concentriques pour lequel des solutions analytiques sont disponibles est utilisé. Les potentiels de surfaces sont calculés aux centroïdes ou aux sommets des éléments de discrétisation BEM utilisés. La performance des approches conventionnelle et réciproque pour le problème direct est évaluée pour des dipôles radiaux et tangentiels d’excentricité variable et deux valeurs très différentes pour la conductivité du crâne. On détermine ensuite si les avantages potentiels de l’approche réciproquesuggérés par les simulations du problème direct peuvent êtres exploités pour donner des solutions inverses plus précises. Des solutions inverses à un seul dipôle sont obtenues en utilisant la minimisation par méthode du simplexe pour à la fois l’approche conventionnelle et réciproque, chacun avec des versions aux centroïdes et aux sommets. Encore une fois, les simulations numériques sont effectuées sur un modèle à trois sphères concentriques pour des dipôles radiaux et tangentiels d’excentricité variable. La précision des solutions inverses des deux approches est comparée pour les deux conductivités différentes du crâne, et leurs sensibilités relatives aux erreurs de conductivité du crâne et au bruit sont évaluées. Tandis que l’approche conventionnelle aux sommets donne les solutions directes les plus précises pour une conductivité du crâne supposément plus réaliste, les deux approches, conventionnelle et réciproque, produisent de grandes erreurs dans les potentiels du cuir chevelu pour des dipôles très excentriques. Les approches réciproques produisent le moins de variations en précision des solutions directes pour différentes valeurs de conductivité du crâne. En termes de solutions inverses pour un seul dipôle, les approches conventionnelle et réciproque sont de précision semblable. Les erreurs de localisation sont petites, même pour des dipôles très excentriques qui produisent des grandes erreurs dans les potentiels du cuir chevelu, à cause de la nature non linéaire des solutions inverses pour un dipôle. Les deux approches se sont démontrées également robustes aux erreurs de conductivité du crâne quand du bruit est présent. Finalement, un modèle plus réaliste de la tête est obtenu en utilisant des images par resonace magnétique (IRM) à partir desquelles les surfaces du cuir chevelu, du crâne et du cerveau/liquide céphalorachidien (LCR) sont extraites. Les deux approches sont validées sur ce type de modèle en utilisant des véritables potentiels évoqués somatosensoriels enregistrés à la suite de stimulation du nerf médian chez des sujets sains. La précision des solutions inverses pour les approches conventionnelle et réciproque et leurs variantes, en les comparant à des sites anatomiques connus sur IRM, est encore une fois évaluée pour les deux conductivités différentes du crâne. Leurs avantages et inconvénients incluant leurs exigences informatiques sont également évalués. Encore une fois, les approches conventionnelle et réciproque produisent des petites erreurs de position dipolaire. En effet, les erreurs de position pour des solutions inverses à un seul dipôle sont robustes de manière inhérente au manque de précision dans les solutions directes, mais dépendent de l’activité superposée d’autres sources neurales. Contrairement aux attentes, les approches réciproques n’améliorent pas la précision des positions dipolaires comparativement aux approches conventionnelles. Cependant, des exigences informatiques réduites en temps et en espace sont les avantages principaux des approches réciproques. Ce type de localisation est potentiellement utile dans la planification d’interventions neurochirurgicales, par exemple, chez des patients souffrant d’épilepsie focale réfractaire qui ont souvent déjà fait un EEG et IRM. / The inverse problem of electroencephalography (EEG) is the localization of current sources within the brain using surface potentials on the scalp generated by these sources. An inverse solution typically involves multiple calculations of scalp surface potentials, i.e., the EEG forward problem. To solve the forward problem, models are needed for both the underlying source configuration, the source model, and the surrounding tissues, the head model. This thesis treats two distinct approaches for the resolution of the EEG forward and inverse problems using the boundary-element method (BEM): the conventional approach and the reciprocal approach. The conventional approach to the forward problem entails calculating the surface potentials starting from source current dipoles. The reciprocal approach, on the other hand, first solves for the electric field at the source dipole locations when the surface electrodes are reciprocally energized with a unit current. A scalar product of this electric field with the source dipoles then yields the surface potentials. The reciprocal approach promises a number of advantages over the conventional approach, including the possibility of increased surface potential accuracy and decreased computational requirements for inverse solutions. In this thesis, the BEM equations for the conventional and reciprocal approaches are developed using a common weighted-residual formulation. The numerical implementation of both approaches to the forward problem is described for a single-dipole source model. A three-concentric-spheres head model is used for which analytic solutions are available. Scalp potentials are calculated at either the centroids or the vertices of the BEM discretization elements used. The performance of the conventional and reciprocal approaches to the forward problem is evaluated for radial and tangential dipoles of varying eccentricities and two widely different skull conductivities. We then determine whether the potential advantages of the reciprocal approach suggested by forward problem simulations can be exploited to yield more accurate inverse solutions. Single-dipole inverse solutions are obtained using simplex minimization for both the conventional and reciprocal approaches, each with centroid and vertex options. Again, numerical simulations are performed on a three-concentric-spheres model for radial and tangential dipoles of varying eccentricities. The inverse solution accuracy of both approaches is compared for the two different skull conductivities and their relative sensitivity to skull conductivity errors and noise is assessed. While the conventional vertex approach yields the most accurate forward solutions for a presumably more realistic skull conductivity value, both conventional and reciprocal approaches exhibit large errors in scalp potentials for highly eccentric dipoles. The reciprocal approaches produce the least variation in forward solution accuracy for different skull conductivity values. In terms of single-dipole inverse solutions, conventional and reciprocal approaches demonstrate comparable accuracy. Localization errors are low even for highly eccentric dipoles that produce large errors in scalp potentials on account of the nonlinear nature of the single-dipole inverse solution. Both approaches are also found to be equally robust to skull conductivity errors in the presence of noise. Finally, a more realistic head model is obtained using magnetic resonance imaging (MRI) from which the scalp, skull, and brain/cerebrospinal fluid (CSF) surfaces are extracted. The two approaches are validated on this type of model using actual somatosensory evoked potentials (SEPs) recorded following median nerve stimulation in healthy subjects. The inverse solution accuracy of the conventional and reciprocal approaches and their variants, when compared to known anatomical landmarks on MRI, is again evaluated for the two different skull conductivities. Their respective advantages and disadvantages including computational requirements are also assessed. Once again, conventional and reciprocal approaches produce similarly small dipole position errors. Indeed, position errors for single-dipole inverse solutions are inherently robust to inaccuracies in forward solutions, but dependent on the overlapping activity of other neural sources. Against expectations, the reciprocal approaches do not improve dipole position accuracy when compared to the conventional approaches. However, significantly smaller time and storage requirements are the principal advantages of the reciprocal approaches. This type of localization is potentially useful in the planning of neurosurgical interventions, for example, in patients with refractory focal epilepsy in whom EEG and MRI are often already performed.
173

Développement d'une nouvelle méthode de caractérisation tissulaire basée sur l'élastographie ultrasonore : application pour le dépistage précoce du cancer du sein

Ouared, Abderrahmane 09 1900 (has links)
Le cancer du sein est le cancer le plus fréquent chez la femme. Il demeure la cause de mortalité la plus importante chez les femmes âgées entre 35 et 55 ans. Au Canada, plus de 20 000 nouveaux cas sont diagnostiqués chaque année. Les études scientifiques démontrent que l'espérance de vie est étroitement liée à la précocité du diagnostic. Les moyens de diagnostic actuels comme la mammographie, l'échographie et la biopsie comportent certaines limitations. Par exemple, la mammographie permet de diagnostiquer la présence d’une masse suspecte dans le sein, mais ne peut en déterminer la nature (bénigne ou maligne). Les techniques d’imagerie complémentaires comme l'échographie ou l'imagerie par résonance magnétique (IRM) sont alors utilisées en complément, mais elles sont limitées quant à la sensibilité et la spécificité de leur diagnostic, principalement chez les jeunes femmes (< 50 ans) ou celles ayant un parenchyme dense. Par conséquent, nombreuses sont celles qui doivent subir une biopsie alors que leur lésions sont bénignes. Quelques voies de recherche sont privilégiées depuis peu pour réduire l`incertitude du diagnostic par imagerie ultrasonore. Dans ce contexte, l’élastographie dynamique est prometteuse. Cette technique est inspirée du geste médical de palpation et est basée sur la détermination de la rigidité des tissus, sachant que les lésions en général sont plus rigides que le tissu sain environnant. Le principe de cette technique est de générer des ondes de cisaillement et d'en étudier la propagation de ces ondes afin de remonter aux propriétés mécaniques du milieu via un problème inverse préétabli. Cette thèse vise le développement d'une nouvelle méthode d'élastographie dynamique pour le dépistage précoce des lésions mammaires. L'un des principaux problèmes des techniques d'élastographie dynamiques en utilisant la force de radiation est la forte atténuation des ondes de cisaillement. Après quelques longueurs d'onde de propagation, les amplitudes de déplacement diminuent considérablement et leur suivi devient difficile voir impossible. Ce problème affecte grandement la caractérisation des tissus biologiques. En outre, ces techniques ne donnent que l'information sur l'élasticité tandis que des études récentes montrent que certaines lésions bénignes ont les mêmes élasticités que des lésions malignes ce qui affecte la spécificité de ces techniques et motive la quantification de d'autres paramètres mécaniques (e.g.la viscosité). Le premier objectif de cette thèse consiste à optimiser la pression de radiation acoustique afin de rehausser l'amplitude des déplacements générés. Pour ce faire, un modèle analytique de prédiction de la fréquence de génération de la force de radiation a été développé. Une fois validé in vitro, ce modèle a servi pour la prédiction des fréquences optimales pour la génération de la force de radiation dans d'autres expérimentations in vitro et ex vivo sur des échantillons de tissu mammaire obtenus après mastectomie totale. Dans la continuité de ces travaux, un prototype de sonde ultrasonore conçu pour la génération d'un type spécifique d'ondes de cisaillement appelé ''onde de torsion'' a été développé. Le but est d'utiliser la force de radiation optimisée afin de générer des ondes de cisaillement adaptatives, et de monter leur utilité dans l'amélioration de l'amplitude des déplacements. Contrairement aux techniques élastographiques classiques, ce prototype permet la génération des ondes de cisaillement selon des parcours adaptatifs (e.g. circulaire, elliptique,…etc.) dépendamment de la forme de la lésion. L’optimisation des dépôts énergétiques induit une meilleure réponse mécanique du tissu et améliore le rapport signal sur bruit pour une meilleure quantification des paramètres viscoélastiques. Il est aussi question de consolider davantage les travaux de recherches antérieurs par un appui expérimental, et de prouver que ce type particulier d'onde de torsion peut mettre en résonance des structures. Ce phénomène de résonance des structures permet de rehausser davantage le contraste de déplacement entre les masses suspectes et le milieu environnant pour une meilleure détection. Enfin, dans le cadre de la quantification des paramètres viscoélastiques des tissus, la dernière étape consiste à développer un modèle inverse basé sur la propagation des ondes de cisaillement adaptatives pour l'estimation des paramètres viscoélastiques. L'estimation des paramètres viscoélastiques se fait via la résolution d'un problème inverse intégré dans un modèle numérique éléments finis. La robustesse de ce modèle a été étudiée afin de déterminer ces limites d'utilisation. Les résultats obtenus par ce modèle sont comparés à d'autres résultats (mêmes échantillons) obtenus par des méthodes de référence (e.g. Rheospectris) afin d'estimer la précision de la méthode développée. La quantification des paramètres mécaniques des lésions permet d'améliorer la sensibilité et la spécificité du diagnostic. La caractérisation tissulaire permet aussi une meilleure identification du type de lésion (malin ou bénin) ainsi que son évolution. Cette technique aide grandement les cliniciens dans le choix et la planification d'une prise en charge adaptée. / Breast cancer is the most frequent cancer in women and the leading cause of death for women between 35 and 55 years old. In Canada, more than 20,000 new cases are diagnosed each year. Most of the previous works have shown that life expectancy is closely related to the precocity of diagnosis. Current diagnostic imaging methods such as mammography, sonography, MRI present limitations such as irradiation (mammography), low specificity and low resolution (sonography) and high cost (MRI). For example, about 95% of abnormalities detected by mammography are proven to be benign lesions after complementary examinations (biopsy). Sonography is useful as a complementary examination but the low resolution of its images, its low specificity (54% for women less than 50 years) and its operator dependent interpretation seriously limit the use of this modality alone. MRI is a non-invasive technique with a relatively high sensitivity (86% for women below 50 years), but its limitations are the high cost and the waiting time for medical examination, which dedicate it as a monitoring technique in high-risk patients. It is therefore necessary to examine new noninvasive and cost effective methods. In this context, dynamic elastography is a promising approach. It is an emerging quantitative medical imaging technique inspired from palpation and based on the determination of elastic properties (stiffness) of tissues. This thesis aims the development of a novel dynamic ultrasound elastography method for early detection of breast lesions. One of the main problems of dynamic elastography techniques using remote palpation (acoustic radiation force) is the strong attenuation of shear waves. After few wavelengths of propagation, displacement amplitudes considerably decrease and their tracking becomes difficult even impossible. This problem greatly affects biological tissue characterization. Moreover, these techniques give only the information about elasticity while recent studies show that some benign lesions have the same elasticity as malignant lesions which affect the specificity of these techniques and motivate investigation of other physical parameters (e.g. viscosity). The first objective of this thesis is to optimize the acoustic radiation force using frequency adaptation to enhance the amplitude of displacements. An analytical model has been developed to predict the optimal frequency for the generation of the radiation force. Once validated on phantoms (in vitro), this model was used for the prediction of the optimal frequencies for the generation of the radiation force in tissue mimicking phantoms and ex vivo human breast cancer samples obtained after total mastectomy. Gains in magnitude were between 20% to158% for in vitro measurements on agar-gelatin phantoms, and 170% to 336% for ex vivo measurements on a human breast sample, depending on focus depths and attenuations of tested samples. The signal-to-noise ratio was also improved by more than four folds with adapted sequences. We conclude that frequency adaptation is a complementary technique that is efficient for the optimization of displacement amplitudes. This technique can be used safely to optimize the deposited local acoustic energy, without increasing the risk of damaging tissues and transducer elements. In the second part of this thesis, a prototype of an ultrasound probe for the generation of a specific type of adaptive shear waves called ''adaptive torsional shear waves'' has been developed. The goal was to use the optimized radiation force (developed in the first part) to generate adaptive torsional shear wave, and prove their utility in improving the amplitude of displacement. During their inward propagation, the amplitude of displacement generated by torsional shear waves was enhanced and the signal to noise ratio improved due to the constructive interferences. Torsional shear waves can also resonate heterogeneities which further enhance the displacement contrast between suspicious masses and its surrounding medium. Finally, in the context of assessment of mechanical proprieties of tissue, the last step of this thesis is to develop an inverse problem based on the propagation of adaptive torsional shear waves to estimate the viscoelastic parameters. A finite element method (FEM) model was developed to solve the inverse wave propagation problem and obtain viscoelastic properties of interrogated media. The inverse problem was formulated and solved in the frequency domain and its robustness was evaluated. The proposed model was validated in vitro with two independent rheology methods on several homogeneous and heterogeneous breast tissue mimicking phantoms over a broad range of frequencies (up to 400Hz). The obtained results were in good agreement with reference rheology methods with discrepancies between 8% and 38% for shear modulus and from 9% to 67% for loss modulus. The robustness study showed that the proposed inverse problem solution yielded a good estimation of the storage (19%) and loss moduli (32%) even with very noisy signals.
174

Estimation des forces musculaires du membre supérieur humain par optimisation dynamique en utilisant une méthode directe de tir multiple

Bélaise, Colombe 07 1900 (has links)
No description available.
175

Analyse, caractérisation et classification de signaux foetaux

Voicu, Iulian 13 December 2011 (has links) (PDF)
Cette thèse s'inscrit dans le domaine biomédical, à l'interface entre l'instrumentation et le traitement du signal. L'objectif de ce travail est d'obtenir, grâce à une mélange de différentes informations, un monitorage de l'activité du fœtus (rythme cardiaque et mouvements fœtaux) pour apprécier son état de bien-être ou de souffrance, et ceci aux différents stades de la grossesse. Actuellement, les paramètres qui caractérisent la souffrance fœtale, issus du rythme cardiaque et des mouvements fœtaux, sont évalués par le médecin et ils sont réunis dans le score de Manning. Deux inconvénients majeurs existent: a) l'évaluation du score est trop longue puisqu'elle dure 1 heure; b) il existe des variations inter et intra-opérateur conduisant à différentes interprétations du bilan médical de la patiente. Pour s'affranchir de ces désavantages nous évaluons le bien-être fœtal d'une façon objective, à travers le calcul d'un score. Pour atteindre ce but, nous avons développé une technologie ultrasonore multi-capteurs (12 capteurs) permettant de recueillir une soixantaine de (paires de) signaux Doppler en provenance du cœur, des membres inférieurs et supérieurs. Dans cette thèse notre première contribution s'appuie sur la mise en œuvre de nouveaux algorithmes de détection du rythme cardiaque (mono-canal et multi-canaux). Notre deuxième contribution concerne l'implémentation de deux catégories de paramètres basés sur le rythme cardiaque : a) la classes des paramètres "traditionnels" utilisés par les obstétriciens et évalués aussi dans le test de Manning (ligne de base, accélérations, décélérations); b) la classe des paramètres utilisés par les cardiologues et qui caractérisent la complexité d'une série temporelle (entropie approximée, entropie échantillonnée, entropie multi-échelle, graphe de récurrence, etc.). Notre troisième contribution consiste également à apporter des modifications notables aux différents algorithmes du calcul des mouvements fœtaux et des paramètres qui en découlent comme : le nombre de mouvements, le pourcentage du temps passé en mouvement par un fœtus, la durée des mouvements. Notre quatrième contribution concerne l'analyse conjointe du rythme cardiaque et des mouvements fœtaux. Cette analyse nous conduit alors à l'identification de différents états comportementaux. Le développement ou le non-développement de ces états est un indicateur de l'évolution neurologique du fœtus. Nous proposons d'évaluer les paramètres de mouvements pour chaque état comportemental. Enfin, notre dernière contribution concerne la mise en œuvre de différents scores et des classifications qui en découlent. Les perspectives directes à donner à ce travail concernent l'intégration des scores ou paramètres les plus pertinents dans un dispositif de surveillance à domicile ou bien dans un dispositif de monitorage clinique.
176

Déconvolution aveugle parcimonieuse en imagerie échographique avec un algorithme CLEAN adaptatif

Chira, Liviu Teodor 17 October 2013 (has links) (PDF)
L'imagerie médicale ultrasonore est une modalité en perpétuelle évolution et notamment en post-traitement où il s'agit d'améliorer la résolution et le contraste des images. Ces améliorations devraient alors aider le médecin à mieux distinguer les tissus examinés améliorant ainsi le diagnostic médical. Il existe déjà une large palette de techniques "hardware" et "software". Dans ce travail nous nous sommes focalisés sur la mise en oeuvre de techniques dites de "déconvolution aveugle", ces techniques temporelles utilisant l'enveloppe du signal comme information de base. Elles sont capables de reconstruire des images parcimonieuses, c'est-à-dire des images de diffuseurs dépourvues de bruit spéculaire. Les principales étapes de ce type de méthodes consistent en i) l'estimation aveugle de la fonction d'étalement du point (PSF), ii) l'estimation des diffuseurs en supposant l'environnement exploré parcimonieux et iii) la reconstruction d'images par reconvolution avec une PSF "idéale". La méthode proposée a été comparée avec des techniques faisant référence dans le domaine de l'imagerie médicale en utilisant des signaux synthétiques, des séquences ultrasonores réelles (1D) et images ultrasonores (2D) ayant des statistiques différentes. La méthode, qui offre un temps d'exécution très réduit par rapport aux techniques concurrentes, est adaptée pour les images présentant une quantité réduite ou moyenne des diffuseurs.
177

Conventional and Reciprocal Approaches to the Forward and Inverse Problems of Electroencephalography

Finke, Stefan 03 1900 (has links)
Le problème inverse en électroencéphalographie (EEG) est la localisation de sources de courant dans le cerveau utilisant les potentiels de surface sur le cuir chevelu générés par ces sources. Une solution inverse implique typiquement de multiples calculs de potentiels de surface sur le cuir chevelu, soit le problème direct en EEG. Pour résoudre le problème direct, des modèles sont requis à la fois pour la configuration de source sous-jacente, soit le modèle de source, et pour les tissues environnants, soit le modèle de la tête. Cette thèse traite deux approches bien distinctes pour la résolution du problème direct et inverse en EEG en utilisant la méthode des éléments de frontières (BEM): l’approche conventionnelle et l’approche réciproque. L’approche conventionnelle pour le problème direct comporte le calcul des potentiels de surface en partant de sources de courant dipolaires. D’un autre côté, l’approche réciproque détermine d’abord le champ électrique aux sites des sources dipolaires quand les électrodes de surfaces sont utilisées pour injecter et retirer un courant unitaire. Le produit scalaire de ce champ électrique avec les sources dipolaires donne ensuite les potentiels de surface. L’approche réciproque promet un nombre d’avantages par rapport à l’approche conventionnelle dont la possibilité d’augmenter la précision des potentiels de surface et de réduire les exigences informatiques pour les solutions inverses. Dans cette thèse, les équations BEM pour les approches conventionnelle et réciproque sont développées en utilisant une formulation courante, la méthode des résidus pondérés. La réalisation numérique des deux approches pour le problème direct est décrite pour un seul modèle de source dipolaire. Un modèle de tête de trois sphères concentriques pour lequel des solutions analytiques sont disponibles est utilisé. Les potentiels de surfaces sont calculés aux centroïdes ou aux sommets des éléments de discrétisation BEM utilisés. La performance des approches conventionnelle et réciproque pour le problème direct est évaluée pour des dipôles radiaux et tangentiels d’excentricité variable et deux valeurs très différentes pour la conductivité du crâne. On détermine ensuite si les avantages potentiels de l’approche réciproquesuggérés par les simulations du problème direct peuvent êtres exploités pour donner des solutions inverses plus précises. Des solutions inverses à un seul dipôle sont obtenues en utilisant la minimisation par méthode du simplexe pour à la fois l’approche conventionnelle et réciproque, chacun avec des versions aux centroïdes et aux sommets. Encore une fois, les simulations numériques sont effectuées sur un modèle à trois sphères concentriques pour des dipôles radiaux et tangentiels d’excentricité variable. La précision des solutions inverses des deux approches est comparée pour les deux conductivités différentes du crâne, et leurs sensibilités relatives aux erreurs de conductivité du crâne et au bruit sont évaluées. Tandis que l’approche conventionnelle aux sommets donne les solutions directes les plus précises pour une conductivité du crâne supposément plus réaliste, les deux approches, conventionnelle et réciproque, produisent de grandes erreurs dans les potentiels du cuir chevelu pour des dipôles très excentriques. Les approches réciproques produisent le moins de variations en précision des solutions directes pour différentes valeurs de conductivité du crâne. En termes de solutions inverses pour un seul dipôle, les approches conventionnelle et réciproque sont de précision semblable. Les erreurs de localisation sont petites, même pour des dipôles très excentriques qui produisent des grandes erreurs dans les potentiels du cuir chevelu, à cause de la nature non linéaire des solutions inverses pour un dipôle. Les deux approches se sont démontrées également robustes aux erreurs de conductivité du crâne quand du bruit est présent. Finalement, un modèle plus réaliste de la tête est obtenu en utilisant des images par resonace magnétique (IRM) à partir desquelles les surfaces du cuir chevelu, du crâne et du cerveau/liquide céphalorachidien (LCR) sont extraites. Les deux approches sont validées sur ce type de modèle en utilisant des véritables potentiels évoqués somatosensoriels enregistrés à la suite de stimulation du nerf médian chez des sujets sains. La précision des solutions inverses pour les approches conventionnelle et réciproque et leurs variantes, en les comparant à des sites anatomiques connus sur IRM, est encore une fois évaluée pour les deux conductivités différentes du crâne. Leurs avantages et inconvénients incluant leurs exigences informatiques sont également évalués. Encore une fois, les approches conventionnelle et réciproque produisent des petites erreurs de position dipolaire. En effet, les erreurs de position pour des solutions inverses à un seul dipôle sont robustes de manière inhérente au manque de précision dans les solutions directes, mais dépendent de l’activité superposée d’autres sources neurales. Contrairement aux attentes, les approches réciproques n’améliorent pas la précision des positions dipolaires comparativement aux approches conventionnelles. Cependant, des exigences informatiques réduites en temps et en espace sont les avantages principaux des approches réciproques. Ce type de localisation est potentiellement utile dans la planification d’interventions neurochirurgicales, par exemple, chez des patients souffrant d’épilepsie focale réfractaire qui ont souvent déjà fait un EEG et IRM. / The inverse problem of electroencephalography (EEG) is the localization of current sources within the brain using surface potentials on the scalp generated by these sources. An inverse solution typically involves multiple calculations of scalp surface potentials, i.e., the EEG forward problem. To solve the forward problem, models are needed for both the underlying source configuration, the source model, and the surrounding tissues, the head model. This thesis treats two distinct approaches for the resolution of the EEG forward and inverse problems using the boundary-element method (BEM): the conventional approach and the reciprocal approach. The conventional approach to the forward problem entails calculating the surface potentials starting from source current dipoles. The reciprocal approach, on the other hand, first solves for the electric field at the source dipole locations when the surface electrodes are reciprocally energized with a unit current. A scalar product of this electric field with the source dipoles then yields the surface potentials. The reciprocal approach promises a number of advantages over the conventional approach, including the possibility of increased surface potential accuracy and decreased computational requirements for inverse solutions. In this thesis, the BEM equations for the conventional and reciprocal approaches are developed using a common weighted-residual formulation. The numerical implementation of both approaches to the forward problem is described for a single-dipole source model. A three-concentric-spheres head model is used for which analytic solutions are available. Scalp potentials are calculated at either the centroids or the vertices of the BEM discretization elements used. The performance of the conventional and reciprocal approaches to the forward problem is evaluated for radial and tangential dipoles of varying eccentricities and two widely different skull conductivities. We then determine whether the potential advantages of the reciprocal approach suggested by forward problem simulations can be exploited to yield more accurate inverse solutions. Single-dipole inverse solutions are obtained using simplex minimization for both the conventional and reciprocal approaches, each with centroid and vertex options. Again, numerical simulations are performed on a three-concentric-spheres model for radial and tangential dipoles of varying eccentricities. The inverse solution accuracy of both approaches is compared for the two different skull conductivities and their relative sensitivity to skull conductivity errors and noise is assessed. While the conventional vertex approach yields the most accurate forward solutions for a presumably more realistic skull conductivity value, both conventional and reciprocal approaches exhibit large errors in scalp potentials for highly eccentric dipoles. The reciprocal approaches produce the least variation in forward solution accuracy for different skull conductivity values. In terms of single-dipole inverse solutions, conventional and reciprocal approaches demonstrate comparable accuracy. Localization errors are low even for highly eccentric dipoles that produce large errors in scalp potentials on account of the nonlinear nature of the single-dipole inverse solution. Both approaches are also found to be equally robust to skull conductivity errors in the presence of noise. Finally, a more realistic head model is obtained using magnetic resonance imaging (MRI) from which the scalp, skull, and brain/cerebrospinal fluid (CSF) surfaces are extracted. The two approaches are validated on this type of model using actual somatosensory evoked potentials (SEPs) recorded following median nerve stimulation in healthy subjects. The inverse solution accuracy of the conventional and reciprocal approaches and their variants, when compared to known anatomical landmarks on MRI, is again evaluated for the two different skull conductivities. Their respective advantages and disadvantages including computational requirements are also assessed. Once again, conventional and reciprocal approaches produce similarly small dipole position errors. Indeed, position errors for single-dipole inverse solutions are inherently robust to inaccuracies in forward solutions, but dependent on the overlapping activity of other neural sources. Against expectations, the reciprocal approaches do not improve dipole position accuracy when compared to the conventional approaches. However, significantly smaller time and storage requirements are the principal advantages of the reciprocal approaches. This type of localization is potentially useful in the planning of neurosurgical interventions, for example, in patients with refractory focal epilepsy in whom EEG and MRI are often already performed.
178

Nanoparticules Chitosane-PEG-FA-ADN pour la thérapie génique non virale et application du gène de l’IL-1Ra dans un modèle expérimental d’arthrite rhumatoïde

Jreyssaty, Christian 04 1900 (has links)
La thérapie génique représente l'un des défis de la médecine des prochaines décennies dont la réussite dépend de la capacité d'acheminer l'ADN thérapeutique jusqu'à sa cible. Des structures non virales ont été envisagées, dont le chitosane, polymère cationique qui se combine facilement à l’ADN. Une fois le complexe formé, l’ADN est protégé des nucléases qui le dégradent. Le premier objectif de l'étude est de synthétiser et ensuite évaluer différentes nanoparticules de chitosane et choisir la mieux adaptée pour une efficacité de transfection sélective in vitro dans les cellules carcinomes épidermoïdes (KB). Le deuxième objectif de l'étude est d'examiner in vivo les effets protecteurs du gène de l'IL-1Ra (bloqueur naturel de la cytokine inflammatoire, l’Interleukine-1β) complexé aux nanoparticules de chitosane sélectionnées dans un modèle d'arthrite induite par un adjuvant (AIA) chez le rat. Les nanoparticules varient par le poids moléculaire du chitosane (5, 25 et 50 kDa), et la présence ou l’absence de l’acide folique (FA). Des mesures macroscopiques de l’inflammation seront évaluées ainsi que des mesures de concentrations de l’Interleukine-1β, Prostaglandine E2 et IL-1Ra humaine secrétés dans le sérum. Les nanoparticules Chitosane-ADN en présence de l’acide folique et avec du chitosane de poids moléculaire de 25 kDa, permettent une meilleure transfection in vitro. Les effets protecteurs des nanoparticules contenant le gène thérapeutique étaient évidents suite à la détection de l’IL-1Ra dans le sérum, la baisse d'expressions des facteurs inflammatoires, l’Interleukine-1 et la Prostaglandine-E2 ainsi que la diminution macroscopique de l’inflammation. Le but de cette étude est de développer notre méthode de thérapie génique non virale pour des applications cliniques pour traiter l’arthrite rhumatoïde et d’autres maladies humaines. / Considered to be one of the medical challenges of the coming decade, the success of gene therapy depends on the ability to deliver therapeutic DNA to target cells. Non-viral polymers, such as chitosan (Ch), a cationic polymer, can be easily combined with DNA. Once a complex is formed, DNA is protected from degradation by nucleases. The first objective of this study was to define the characteristics of the best-suited Ch nanoparticle for maximum selective transfection in human epidermoid carcinoma (KB) cells in vitro. Nanoparticles varied by the presence or absence of folic acid (FA) and Ch’s molecular weight (MW 5, 25 and 50 kDa). They were then selected and combined with interleukin-1 receptor antagonist (IL-1Ra) gene, a natural blocker of the inflammatory cytokine interleukin-1beta (IL-1β). The second objective was to inject these carriers by the hydrodynamic method in a rat model of adjuvant-induced arthritis and to evaluate the inhibitory effects of IL-1Ra against inflammation in vivo. Ch-DNA nanoparticles with FA and Ch25 demonstrated selective transfection and significantly increased it in KB cells in vitro. The inhibitory effects of IL-1Ra gene therapy in vivo were evident from lower expression levels of inflammatory factors (IL-1 and prostaglandin E2) and decreased macroscopic limb inflammation. The results also revealed the presence of human recombinant IL-1Ra protein in rat sera. Non-viral gene therapy with Ch-PEG-FA-DNA nanoparticles containing the IL-1Ra gene appears to significantly decrease inflammation in this experimental model of arthritis.
179

Microscopie par génération de second harmonique résolue en polarisation : développements théoriques et expérimentaux et application à l'imagerie de la microstructure du tendon pendant des essais mécaniques.

Gusachenko, Ivan 29 October 2012 (has links) (PDF)
Le collagène est une protéine de structure majeure qui forme diverses organisations macromoléculaires dans les tissus, et est responsable des propriétés biomécaniques de la plupart des organes. La génération de seconde harmonique (SHG) est une technique d'imagerie adaptée pour sonder l'organisation fibrillaire du collagène. Ce travail vise à implémenter et à caractériser la SHG résolue en polarisation (PSHG), et à coupler cette technique à des essais biomécaniques pour obtenir des informations structurelles multi échelles sur les tissus collagéniques. Nous avons d'abord étudié les effets optiques linéaires qui influencent l'imagerie P-SHG dans les tissus anisotropes denses tels que les tissus collagéniques. Nous avons développé un modèle théorique qui prend en compte la biréfringence, la di-atténuation et le mélange de polarisation, et nous avons obtenu un excellent accord avec nos mesures P-SHG dans le tendon de queue de rat. De plus, nous avons effectué des simulations numériques de la propagation du faisceau d'excitation et de la formation du signal SHG dans le tendon et la cornée. Ces simulations ont confirmé le rôle crucial de la biréfringence en P-SHG. Nous avons ensuite mis en place un dispositif expérimental combinant des essais mécaniques avec l'imagerie SHG. Cela a permis de visualiser la morphologie du tendon à l'échelle micrométrique pendant les essais mécaniques macroscopiques. Nos résultats ont montré que l'imagerie SHG sous traction permet d'élucider le lien entre la réponse macroscopique des tissus et leur structure microscopique. Enfin, nous avons développé un modèle théorique pour relier l'anisotropie du signal P-SHG à l'ordre orientationnel submicrométrique des harmonophores dans le tissu. Nous avons testé ce modèle par des mesures P-SHG sur un tendon soumis à une élongation croissante. Nous avons alors caractérisé avec succès les variations d'organisation des fibrilles dans le tendon en fonction de l'élongation.
180

Commande optimale appliquée aux systèmes d'imagerie ultrasonore

Ménigot, Sébastien 12 December 2011 (has links) (PDF)
Les systèmes d'imagerie médicale ultrasonore ont considérablement amélioré le diagnostic clinique par une meilleure qualité des images grâce à des systèmes plus sensibles et des post-traitements. La communauté scientifique de l'imagerie ultrasonore a consenti à un très grand effort de recherche sur les post-traitements et sur le codage de l'excitation sans s'intéresser, outre mesure, aux méthodes de commande optimale. Ce travail s'est donc légitimement tourné vers les méthodes optimales basées sur l'utilisation d'une rétroaction de la sortie sur l'entrée. Pour rendre applicable ces méthodes, ce problème complexe de commande optimale a été transformé en un problème d'optimisation paramétrique sous-optimal et plus simple. Nous avons appliqué ce principe au domaine de l'imagerie ultrasonore : l'échographie, l'imagerie harmonique native et l'imagerie harmonique de contraste avec ou sans codage de la commande. La simplicité de l'approche nous a permis, par une modification de la fonction de coût, de l'adapter à l'imagerie harmonique. Cette adaptation montre que la méthode peut être appliquée à l'imagerie ultrasonore en générale. Aujourd'hui, les enjeux de l'imagerie ultrasonore portent non seulement sur les traitements des excitations ou des images mais aussi sur les capteurs. Ce point nous a conduit naturellement à rechercher la commande optimale des transducteurs capacitifs (cMUT) afin de les adapter à une utilisation plus large en imagerie ultrasonore codée. Nos méthodes de compensation et de codage par commande optimale procurent des résultats très prometteurs qui vont au delà de nos espérances. Le champ d'applications de nos méthodes de codage optimal est large et nous n'en voyons pas forcément encore toutes les limites. L'atout majeur de nos approches est leur simplicité d'utilisation et d'implémentation. En effet, elles ne nécessitent pas d'informations a priori difficilement accessibles sur les outils utilisés ou milieux explorés. Notre système s'adapte automatiquement aux variations qui peuvent être liées au vieillissement du capteur ou à la modification du milieu exploré.

Page generated in 0.1191 seconds