• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 64
  • 48
  • Tagged with
  • 195
  • 195
  • 145
  • 132
  • 128
  • 128
  • 54
  • 47
  • 47
  • 47
  • 46
  • 40
  • 30
  • 28
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Suivi par élastographie ultrasonore après réparation endovasculaire d’anévrisme aorto-iliaque : étude de faisabilité in vivo

Bertrand-Grenier, Antony 12 1900 (has links)
No description available.
162

Développement d'indicateurs biomécaniques en manutention et leur application dans l'étude des différences entre les sexes lors de levers de charges en hauteur

Martinez, Romain 09 1900 (has links)
Les blessures musculo-squelettiques du membre supérieur représentent un problème de santé publique dans le secteur de la manutention. En plus d’affecter la qualité de vie du travailleur, ces lésions entraînent une perte de temps de travail et une augmentation des coûts de production. Alors que nous avons des évidences épidémiologiques que les femmes manutentionnaires sont plus nombreuses que les hommes à souffrir de douleurs à l’épaule, la littérature fait défaut d’indices biomécaniques qui expliquent l'origine de cette différence. L'objectif général de cette thèse était d'améliorer l'évaluation des techniques de manutention du membre supérieur, avec trois objectifs spécifiques : (1) développer des indices cinématiques, électromyographiques et musculo-squelettiques synthétiques pour évaluer et différencier des techniques de manutention du membre supérieur ; (2) développer un logiciel libre d'analyse biomécanique ; et (3) utiliser les indices et le logiciel développés pour décrire les différences biomécaniques entre des femmes et des hommes manutentionnaires. Nous avons récolté des données de cinématique, d'électromyographie et de force sur 30 femmes et 30 hommes réalisant une tâche de manutention qui consistait à déplacer une boîte de 6 et 12 kg entre la hauteur des hanches et la hauteur des yeux. À partir de ces données, nous avons développé des indicateurs synthétiques : un indicateur cinématique utile pour identifier des techniques de manutention problématiques et plus généralement les fonctions articulaires ; des indicateurs électromyographiques qui permettent d'estimer la quantité d'activation musculaire et la co-contraction musculaire ; et des indicateurs musculo-squelettiques qui permettent d'estimer les contraintes musculaires totales et les contraintes appliquées à l'articulation glénohumérale. Nous avons implémenté ces indicateurs avec pyomeca, notre logiciel libre d'analyse biomécanique. Mis à disposition de la communauté biomécanique, pyomeca supporte des tâches utiles dans le quotidien d'un chercheur biomécanique, mais également des routines biomécaniques plus avancées, axées sur la mécanique du corps rigide et le traitement de signal. Ce dernier se démarque des logiciels biomécaniques existants parce que c'est une solution libre, conviviale, spécialisée et sûre. Nous avons ensuite appliqué les indices synthétiques pour décrire les différences biomécaniques entre les femmes et les hommes participant à notre expérimentation. L'indicateur cinématique a montré que les femmes employaient une technique de manutention moins sécuritaire, avec une plus grande contribution glénohumérale, une faible contribution des membres inférieurs et une boite plus éloignée du tronc. Ces différences de technique se sont répercutées sur les indicateurs électromyographiques et musculo-squelettiques, avec des activations musculaires deux fois plus importantes comparativement aux hommes et une moindre stabilité de l'articulation glénohumérale. Ces différences pourraient contribuer à expliquer la prévalence de blessure du membre supérieur plus élevée chez les femmes manutentionnaires. Cette thèse a donc permis de développer des indicateurs synthétiques et un logiciel libre d'analyse biomécanique qui pourraient permettre aux ergonomes d'évaluer l'exposition aux risques de blessures du membre supérieur pendant une tâche de travail dynamique. Appliqués à une population spécifique, ces indicateurs suggèrent qu'il est crucial d'accorder une attention particulière au sexe pendant l'évaluation d'une tâche de travail au-dessus des épaules. / Work-related upper limb musculoskeletal disorders represent a public health challenge in the material handling industry. In addition to affecting the worker's quality of life, these injuries result in lost work time and increased production costs. While we have epidemiological evidence that more female material handlers suffer from shoulder pain than men, the literature is lacking biomechanical indicators that explain the origin of this difference. The general objective of this thesis was to improve the evaluation of upper limb handling techniques, with three specific objectives~: (1) to develop synthetic kinematic, electromyographic and musculoskeletal indicators to evaluate and differentiate upper limb handling techniques~; (2) to develop an open source biomechanical analysis software~; and (3) to use the developed indicators and software to describe the biomechanical differences between female and male workers. We collected kinematics, electromyography and force data on 30 women and 30 men performing a handling task that consisted in lifting a 6 and 12~kg box from hip to eye level. From these data, we developed synthetic indicators~: a kinematic indicator useful to identify poor handling techniques and more generally joint functions~; two electromyographic indicators to quantify the amount of muscle activation and muscle co-contraction~; and two musculoskeletal indicators to estimate total muscle stress and stress applied to the glenohumeral joint. We have implemented these indicators with pyomeca, our open-source biomechanical analysis software. Available to the biomechanical community, pyomeca provide basic operations useful in the daily workflow of a biomechanical researcher, but also more advanced biomechanical routines geared towards rigid body mechanics and signal processing. pyomeca stands from existing biomechanical software because it is an open-source, user-friendly, specialized and secure solution. We then applied our synthetic indicators to describe the biomechanical differences between the women and men participating in our experiment. The kinematic indicator showed that women used a poor handling technique, with a higher glenohumeral contribution, a low contribution from the lower limbs and a box further away from the trunk. These differences in technique affected the electromyographic and musculoskeletal indicators, with twice as much muscle activation compared to men and less glenohumeral stability. These results may contribute to the sex difference in the prevalence of upper limb musculoskeletal disorders. This thesis has enabled the development of biomechanical indicators and an open-source software that could allow ergonomists to assess the upper limb exposure during a dynamic lifting task. Applied to a specific population, these indicators argue for a careful consideration of sex during ergonomics intervention, particularly during overhead work.
163

Amélioration de la géométrie des modèles musculosquelettiques de l'épaule

Hoffmann, Marion 09 1900 (has links)
Pour mieux comprendre et traiter les troubles musculosquelettiques présents à l’épaule, une meilleure connaissance de la contribution et de la fonction de chaque muscle de l’articulation glénohumérale est nécessaire. L’analyse des forces musculaires et articulaires est une étape importante pour comprendre les mécanismes de blessures et les pathologies. Ces forces musculaires peuvent être estimées de façon non invasive grâce à des modèles musculosquelettiques. Le défi est de prédire de façon physiologique les trajectoires musculaires et les bras de levier afin de s’assurer d’avoir une cohérence des forces musculaires dans les modèles musculosquelettiques. L’objectif de cette thèse était d’améliorer la géométrie musculaire des modèles musculosquelettiques de l’épaule en passant par plusieurs méthodes différentes d’implémentation des trajectoires musculaires. À cet égard, nos objectifs spécifiques étaient de : (1) améliorer la géométrie musculaire des modèles multicorps rigides grâce à l’implémentation de contraintes transverses; (2) évaluer la fiabilité d’un modèle éléments finis pour l’estimation des bras de levier et (3) tester la sensibilité de la prédiction des bras de levier aux incertitudes sur les zones d’insertions musculaires; (4) établir une base de données de bras de levier 3D pour des mouvements de grande amplitude; (5) quantifier de façon expérimentale les changements architecturaux des muscles entre l’état au repos et différents niveaux de contraction isométrique. (1) Deux modèles multicorps rigides de la coiffe des rotateurs ont été développés : un modèle classique intégrant une représentation des lignes d’action en 1D et un modèle possédant des contraintes transverses entre les lignes d’action permettant une représentation 2D. La représentation 2D avec des contraintes transverses permet une représentation plus physiologique des trajectoires musculaires et des bras de levier que les modèles classiques 1D. Toutefois, lors de mouvement allant au-delà de 90° d’élévation du bras, lorsque les points d’origine et d’insertion se rapprochent, les bras de levier et les longueurs musculaires sont mal estimés, car le modèle ne prend pas en compte les déformations du volume musculaire. (2) Un modèle éléments finis a été développé à partir de données d’imagerie médicale. Ce modèle permet une estimation des bras de levier fidèle aux données d’IRM. Contrairement aux modèles multicorps rigides, notre modèle élément finis rend compte du fait qu’un même muscle peut avoir plusieurs actions selon la position de sa ligne d’action par rapport au centre de rotation de l’articulation. (3) Le modèle a également servi à faire une étude de sensibilité des bras de levier : les zones d’insertion des différents muscles de la coiffe des rotateurs et du deltoïde ont été déplacées et les bras de levier associés calculés. Les résultats montrent qu’une variation de 10 mm des points d’insertion sur la tête humérale peut amener un muscle à changer de fonction (par exemple adduction plutôt que d’abduction). (4) Une collecte de données expérimentales effectuées sur quatre épaules a permis de collecter les bras de levier du deltoïde et des muscles de la coiffe des rotateurs pour des mouvements de grande amplitude. Ces résultats permettent de mieux comprendre le rôle des muscles de l’articulation glénohumérale lors de la réalisation de différents mouvements. Le deltoïde antérieur a une grande action en flexion et en adduction; le deltoïde moyen est un fort abducteur; le deltoïde postérieur agit en extension. Contrairement au deltoïde, l’infra-épineux et le petit rond ont principalement une fonction de rotateur externe. (5) Une collecte de données impliquant 14 sujets a été réalisée dans le but de quantifier les changements de géométrie musculaire et d’angle de pennation associés à la contraction pour les muscles du biceps, triceps et deltoïde. Les angles de pennation ont été obtenus grâce à un système d’échographie et les changements de géométrie externe des muscles ont été mesurés grâce à un capteur de structure. Les résultats montrent que les changements architecturaux pour les muscles étudiés se produisent principalement entre 0 et 25% de contraction maximale volontaire (aucune différence significative observée entre 25 et 50%). Le muscle le plus affecté par les changements architecturaux est le biceps. Cette thèse a évalué différentes approches de modélisation de la géométrie musculaire : l’approche la plus bio-fidèle étant finalement la modélisation par éléments finis, car elle permet de prendre en compte les interactions entre les structures et les déformations musculaires. De plus, nous avons montré l’importance d’estimer avec rigueur les paramètres d’entrée (zones d’insertions musculaires) des modèles et de bien évaluer la bio-fidèlité des modèles développés avant de les utiliser dans des contextes cliniques. Dans ce but, de nouvelles données ont été acquises en termes de déformations musculaires et d’angle de pennation pour permettre l’évaluation de modèle intégrant de l’activation musculaire. / Understanding and treating musculoskeletal disorders of the shoulder requires additional knowledge of the contribution and function of each muscle of the glenohumeral joint. The analysis of muscle and joint forces is an important step in understanding injury mechanisms and pathologies. These muscle forces can be estimated non-invasively using musculoskeletal models. The challenge is to physiologically predict muscle trajectories and moment arms to ensure consistency of muscle forces in musculoskeletal models. The aim of this thesis was to improve muscle geometry in musculoskeletal models of the shoulder by testing several different techniques for implementing muscle trajectories. Our specific objectives were to: (1) improve muscle geometry of rigid multibody models by using transverse constraints; (2) assess the reliability of a finite element model for estimating moment arms and (3) evaluate the sensitivity of moment arm predictions to uncertainties in muscle insertion areas; (4) create a database of 3D moment arms for movements with high ranges of motion; (5) experimentally quantify muscles’ architectural changes between resting state and different levels of isometric contractions. (1) Two rigid multibody models of the rotator cuff were developed: a classic model representing muscles with lines of action in 1D and a 2D model with transverse constraints between lines of action of a single muscle. The 2D model (with transverse constraints) gives a more physiological representation of muscle trajectories and moment arms than the classical 1D model. However, for arm movements beyond 90° of elevation, when the origin and insertion points get closer, moment arms and muscle lengths are misestimated due to the mode’s inability to account for muscle volume deformations. (2) A finite element model of the glenohumeral joint was developed based on medical imaging. Moment arms were computed and compared to the literature and MRI data. Our finite element model produces moment arms consistent with the literature and MRI data. Unlike rigid multibody models, our finite element model accounts for the fact that one muscle can have several actions depending on the position of its line of action relative to the centre of rotation of the joint. (3) The model was used to study moment arm sensitivity: insertion areas of rotator cuff muscles and the deltoid were moved, and associated moment arms have been computed. Results showed that a 10 mm variation in insertion points on the humeral head could cause a muscle to change function (for example performing adduction rather than abduction). (4) The 3D moment arms were assessed on four post-mortem human surrogates during movements with high ranges of motion. Results of the study gave us a better understanding of muscle functions during different movements. The main findings of the study were that the anterior deltoid was the largest flexor and had an adduction component, the median deltoid was a strong abductor, and the posterior deltoid acted in extension. Unlike the deltoid, the infraspinatus and teres minor were the largest external rotators of the shoulder. (5) Experimental measurements were performed on 14 subjects in order to quantify changes in muscle geometry and pennation angles associated with different levels of contraction for the biceps, triceps and deltoid. Pennation angles were measured on subjects using a portable ultrasound system. External muscle deformations were measured with an iPad equipped with a structure sensor. Changes in muscle architecture for the biceps, triceps and deltoid during isometric contractions occurred mostly between 0 and 25% of maximal voluntary contraction (no significant difference was observed between 25 and 50%). Changes were higher for the biceps than other muscles. This thesis evaluated different approaches to model muscle geometry: the approach leading to the most physiological result was the finite element model due to modeling of the interactions between structure and muscle deformations. Additionally, we demonstrated the importance of rigorously estimating input parameters (muscle insertion areas) and of properly evaluating the bio-fidelity of the models developed before using them in clinical contexts. New data was acquired regarding muscle deformations and pennation angles to evaluate models integrating muscle activation.
164

Développement de timbres de microaiguilles polymériques superabsorbantes pour le prélèvement indolore de liquide interstitiel dermique

Laszlo, Elise 08 1900 (has links)
Le liquide interstitiel est aujourd’hui considéré comme un candidat prometteur comme alternative, ou complément, à l’analyse sanguine pour la quantification de biomarqueurs. Localisé notamment dans la peau, sa composition demeure peu décrite dans la littérature. Cela peut s’expliquer par le fait que le prélèvement de liquide interstitiel reste problématique. En effet, les méthodes d’extraction actuelles sont chronophages, douloureuses et conduisent au prélèvement de volumes très faibles ne permettant pas toujours une analyse subséquente. L’utilisation de timbres de microaiguilles conçus en hydrogel superabsorbant représente une solution indolore, rapide et efficace pour le prélèvement du liquide interstitiel. Un premier type de timbre a été conçu par photopolymérisation, un processus de fabrication caractérisé par sa rapidité. Ce type de timbre de microaiguilles présente une capacité d’absorption très élevée et peut trouver une application dans l’élaboration des profils protéomique, métabolomique et lipidomique du liquide interstitiel dermique. Le second type de timbres de microaiguilles est obtenu par chauffage d’une formulation contenant des polymères superabsorbants. Ce procédé s’avère plus long mais conduit à un hydrogel superabsorbant riche en groupements chimiques permettant d’envisager une fonctionnalisation pour la capture et la détection in situ de biomarqueurs spécifiques du liquide interstitiel dermique. In fine, les timbres de microaiguilles développés pourraient donc permettre d’approfondir notre connaissance de la composition du liquide interstitiel; mais laissent également entrevoir la possibilité de développer des dispositifs médicaux portables permettant le diagnostic, ou la surveillance, rapide et indolore de certaines pathologies. Ces dispositifs pourraient diminuer les coûts normalement associés à ces pratiques et améliorer la prise en charge des patients. C’est le cas notamment de l’insuffisance cardiaque, dont la gestion pourrait être considérablement facilitée par le suivi à domicile du biomarqueur NT-proBNP. / Nowadays, interstitial fluid is considered a valid alternative for blood analysis and biomarker monitoring. However, its composition is scarcely described in the literature. Notably located in the skin, its collection remains a challenge as current methods are time-consuming, painful and the extracted volume limits subsequent analysis. Here we put forward the use of superabsorbant hydrogel-based microneedle patches to enable a painless, rapid and efficient sampling of dermal interstitial fluid. A first kind of microneedle patch was obtained using UV-curing, a rapid fabrication process. This type of microneedle patch enables the collection of a high volume of liquid and can therefore be utilized for subsequent proteomic, metabolomic and lipidomic analyses of the dermal interstitial fluid that had been extracted in a painless fashion. The second class of microneedle patch developed was fabricated from superabsorbant polymers using heating. Although time consuming, this process produced hydrogel-based microneedle patches that could be functionalized for the in situ detection of specific biomarkers in the dermal interstitial fluid. In fine, the aforementioned microneedle patches have the potential to broaden our understanding of the interstitial fluid composition, as well as be integrated in novel portable biosensing devices for a rapid and painless diagnosis, or for the monitoring of certain medical conditions. For example, quantifying the NT-proBNP biomarker in the dermal interstitial fluid could significantly improve the quality of life of heart failure patients.
165

Analyses biomécaniques de l'interaction acrobate-équipement de cirque dans la performance acrobatique en planche coréenne

Cossin, Marion 10 1900 (has links)
La planche coréenne est une discipline de cirque exigeante d’un point de vue technique. Il s’agit d’une longue planche à bascule sur laquelle deux acrobates, placés à chaque extrémité, se catapultent continuellement pour effectuer des sauts acrobatiques. Les acrobates utilisent une technique spécifique pour le décollage et l’atterrissage. La planche coréenne, comme tout équipement de cirque, n’a pas de standard de fabrication et il existe une grande variété de planches. Les acrobates, les entraîneurs et les concepteurs d'équipements bénéficieraient d’avoir plus d'informations sur la biomécanique de la performance et sur la mécanique de la planche, afin d'améliorer le développement des techniques acrobatiques et la conception des planches. L’objectif de la thèse était de mieux comprendre l’interaction entre l’équipement de cirque et la performance acrobatique en planche coréenne. À cet égard, les quatre objectifs spécifiques étaient de : (1) Établir l’influence de la hauteur de saut, du participant, de la planche et de la technique de réception sur les forces d’impact et les taux de chargement; (2) Quantifier l’influence de plusieurs facteurs biomécaniques cinématiques sur la hauteur de saut; (3) Déterminer la différence de contribution musculaire et de durée des phases du mouvement entre acrobates débutants et acrobates élites; et (4) Caractériser mécaniquement différentes planches et mettre en évidence la contribution du renvoi de flexion de la planche sur la hauteur de sauts. Cette thèse présente l’ensemble des travaux effectués pour lier les caractéristiques de la planche au mouvement de l’acrobate. En effet, le mouvement de l’acrobate, sauter à grande hauteur, génère des forces élevées sur la planche lors de la réception, ce qui met en mouvement la planche. L’équipement ensuite permet un transfert de force vers l’acrobate qui s’élance. Finalement, ce dernier doit utiliser une technique optimale avec une synchronisation et une contribution musculaire précis, afin de gagner une hauteur suffisante pour la performance. Nos différentes études ont permis de montrer que le facteur qui influence le plus les forces d’impact et le taux de chargement lors de la réception est la hauteur de saut (40% d’influence relative). La force maximale mesurée est de 13.5 fois le poids corporel de l’acrobate, ce qui peut représenter un risque de blessure. La hauteur de saut est en majorité influencée par la vitesse verticale du centre de masse de l’acrobate-partenaire qui se réceptionne, de la vitesse verticale de la planche et de l’amplitude des hanches lors du décollage. Ces deux derniers paramètres peuvent être contrôlés par les acrobates ou les concepteurs de planche coréenne. Nous démontrons, de plus, que les acrobates débutants sont plus longs dans la préparation au décollage, le décollage et l’atterrissage comparativement aux acrobates experts. Cependant, il n’y avait pas de différence claire entre les débutants et les professionnels quant à l’activité musculaire lors du décollage et atterrissage, ce qui indique que la temporalité est sûrement plus importante que l’activité musculaire. Nous trouvons aussi que le renvoi de flexion (énergie élastique de la planche) est non négligeable (46 % d’influence relative) et contribue donc à la hauteur de saut. Finalement, le paramètre mécanique le plus important pour quantifier et comparer les planches est la raideur. Les quatre planches de l’étude ont une raideur qui varie entre 12.2 kN/m et 19.6 kN/m. Ce paramètre peut probablement guider les futures conceptions de planche. Collectivement, ces quatre études mettent en évidence que la synchronisation temporelle du mouvement des acrobates et du mouvement de la planche est l’élément crucial dans cette discipline. / Korean teeterboard is a technically demanding circus discipline. The apparatus resembles a seesaw, and two acrobats take turns jumping vertically, performing complex acrobatic figures and landing back on the apparatus. Acrobats use a specific technique during take-off and landing. Furthermore, like most circus equipment, there are no standards regarding the design of the teeterboard and there is a wide variety of teeterboards. Acrobats, trainers and equipment’s designers would benefit to know more about the relationship between the biomechanics of the performance and the mechanics of the board. This understanding would help improving acrobatic techniques and optimize the design of teeterboards. The purpose of the thesis was to better understand the interaction between the circus equipment and the acrobats’ performance in Korean teeterboard. To this end, this thesis was divided into four specific goals: (1) Define the influence of the jump height, the teeterboard and the landing technique on impact forces and loading rates; (2) Quantify the influence of various kinematic factors to the jump height; (3) Determine the differences between expert and novice acrobats with respect to muscular contribution and duration of the phases of the movement ; and, (4) mechanically characterize different types of teeterboards and highlight the contribution of the recoil effect to the jump height. This thesis covers the work carried out to link the characteristics of the teeterboard to the movement of the acrobat. The movement of the acrobat, i.e., jumping at high height, generates high forces during landing, which set in motion the board. The equipment then enables the transfer of this force to the other acrobat taking-off. This acrobat should use an optimal technique with a precise timing and muscular contribution, to gain sufficient height for their performance. This body of work demonstrated that the most important factor influencing the impact forces and loading rates was jump height (40% of relative influence). Maximal recorded force was 13.5 times the acrobat’s bodyweight, raising concerns about risk of injury. Jump height was mainly influenced by the vertical velocity of the center of mass of the acrobat landing, the vertical velocity of the teeterboard and the hip range of motion at take-off. The last two parameters can be controlled by acrobats, trainers, or designers of Korean teeterboard. We also found that novice acrobats are longer in the following phases: preparation for take-off, take-off, and landing. However, there was no clear difference in muscular amplitude during take-off and landing between novice and professional acrobats. This indicates that timing may be more important than muscular amplitude. We showed that recoil effect (elastic strain energy of the board) strongly contributed to the jump height (46% of relative influence). Finally, the most important mechanical parameter to quantify and compare teeterboards was the stiffness. The stiffness of the four teeterboards analyzed in this study ranged from 12.2 kN/m to19.6 kN/m. This result can guide future designs of teeterboard. The results from this thesis highlight the fact that temporal synchronization of the movement from both acrobats and the movement of the board is crucial in this discipline.
166

Biocompatibilité des nanoparticules de chitosane-siRNA in vitro pour la thérapie génique

Rondon-Cavanzo, Elsa-Patricia 08 1900 (has links)
Le chitosane est un polysaccharide naturel, généralement reconnu pour sa biocompatibilité et biodégradabilité. Sa notoriété se doit non seulement à la diversité de ses applications biomédicales, mais aussi à la disponibilité des groupes fonctionnels qui permettent la modification de ses caractéristiques physicochimiques. Dans le contexte de la thérapie génique, le chitosane est reconnu pour son potentiel en tant que nanovecteur, pour transporter du matériel génique à l’intérieur des cellules. Notre laboratoire a mis au point la synthèse d’un diéthylaminoéthyl-chitosane-polyéthylène glycol-acide folique (DEAE12-CH-PEG-FA2), qui a déjà démontré sa capacité de transfection in vitro sur plusieurs lignées cellulaires et son potentiel thérapeutique en tant que nanoparticule dans un modèle animal d’arthrite. Ces résultats prometteurs ont encouragé la suite de nos recherches. Ainsi, l’évaluation des propriétés cytotoxiques et hémotoxiques de notre chitosane modifié et de ses nanoparticules s’est avérée une étape essentielle pour continuer vers une potentielle application clinique. Étant donné les résultats contradictoires des rapports sur les caractéristiques hémocompatibles de ce polymère, en plus du manque de témoins d’interférence, de l’absence de données sur le niveau de contamination aux endotoxines des formulations et l’hétérogénéité des protocoles expérimentaux dans la littérature, nous avons employé les lignes directrices de l’ISO, l’ASTM et le NCL pour estimer son profil toxicologique. Dans cette étude, nous avons approfondi les connaissances sur l'hémocompatibilité des nanoparticules de DEAE12-CH-PEG-FA2/siRNA dans un cadre contrôlé et informatif. Cette évaluation a montré une faible réponse hémolytique et d’agrégation plaquettaire, et aucun effet sur le système du complément et sur le temps de coagulation du plasma. Également, la mesure du niveau de radicaux libres (ROS et NO) n’a pas décelé une réponse biologique reliée au stress oxydatif. Cependant, la viabilité cellulaire et le niveau de libération de la lactate déshydrogénase (LDH) ont révélé une relation en fonction de la concentration, du temps d’exposition et du type cellulaire étudié. Enfin, l’expression de cytokines telles que le TNF-α, l’IL-6, l’IL-4 et l’IL-10 ont été comparables à ceux du témoin négatif, le PBS. Dans cette quête de l’estimation des propriétés biocompatibles de notre chitosane, notre projet s’est dirigé vers l’étude des mécanismes moléculaires. C’est ainsi que nous avons étudié les voies de signalisation reliées aux récepteurs de surface cellulaire susceptibles de reconnaître le chitosane, notamment le récepteur toll-like 4 (TLR-4) et les récepteurs de lectine de type C (CLR). Nos données révèlent que les nanoparticules de DEAE12-CH-PEG-FA2/siRNA, à différentes concentrations et à différentes périodes d’incubation, n’activent pas les voies de signalisation des IKK/NF-κβ, MAPKs, AKT et SYK. Ces résultats ont été supportés par l’absence d’une réponse pro-inflammatoire mesurée à partir de l’expression de médiateurs clés comme le TNF-α, IL-1β, IL-6, COX-2 et iNOS. Au vu de nos découvertes, nous pouvons déduire le potentiel d’innocuité de notre chitosane modifié (DEAE12-CH-PEG-FA2), indispensable pour son application dans la thérapie génique. Également, nous suggérerons la possibilité que des récepteurs cellulaires qui n’ont pas encore été identifiés soient impliqués dans la reconnaissance et l’internalisation du chitosane, ce qui mérite la réalisation d’études plus approfondies. / Chitosan is a natural polysaccharide, generally known for its biocompatibility and biodegradability. Its notoriety is due not only to the diversity of its biomedical applications but also to the presence of functional groups in its chain, which allow the modification of its physiochemical properties. In gene therapy applications, chitosan is known for its potential as a nanovector to transport genetic material to cells. Our laboratory has synthesized a modified-chitosan diethylaminoethyl-chitosan-polyethylene glycol-folic acid (DEAE12-CH-PEG-FA2), which has already shown in vitro transfection efficiency in several cell lines and a therapeutic potential as a nanoparticle in an animal arthritis model. These promising results encouraged further research. Thus, the evaluation of the cytotoxic and hemotoxic properties of our modified chitosan and its nanoparticles became an essential step to continue towards potential clinical applications. Given the existing contradictory outcomes about the hemocompatible characteristics of this polymer, as well as the lack of interference controls, the absence of data on endotoxin levels in nanoformulations and the diversity of the experimental protocols, we used ISO, ASTM and NCL’s guidelines to estimate its toxicological profile. In this study, we discovered new information about DEAE12-CH-PEG-FA2/siRNA nanoparticle hemocompatibility, in a controlled and informative framework. This evaluation showed low hemolytic properties, low platelet aggregation capacity with no effect on the complement and coagulation systems. Moreover, detection of free radical levels (ROS and NO) did not show a biological response related to oxidative stress. Nevertheless, cell viability and the levels of lactate dehydrogenase (LDH) release revealed concentration-, incubation time- and cell-dependent outcomes. Regarding cytokine expression, TNF-α, IL-6, IL-4 and IL-10 levels were equivalent to those of the negative control, PBS. In the quest to evaluate the biocompatible properties of chitosan, our project focused on the study of its molecular mechanisms. Therefore, we studied signaling pathways related to receptors that have been associated to chitosan recognition such as toll-like receptor 4 (TLR-4) and C-type lectin receptors (CLRs). Our data revealed that DEAE12-CH-PEG-FA2/siRNA nanoparticles, at the studied concentrations and time courses, did not activate the IKK/NF-κB, MAPKs, AKT nor SYK signaling pathways. These results were supported by the absence of an inflammatory response measured by the expression of key mediators such as TNF-α, IL-1β, IL-6, COX-2 and iNOS. In view of our findings, we deduced the safety potential of our modified chitosan (DEAE12-CH-PEG-FA2) which is mandatory for gene therapy applications. Moreover, we suggest the involvement of unidentified cellular receptors in the recognition and uptake of chitosan which warrant further investigation.
167

Novel, universal electrochemical DNA-based signaling mechanisms for molecular detection in a drop of blood

Zhu, Guichi 10 1900 (has links)
Une percée majeure aura lieu dans le domaine de la santé lorsque les patients pourront surveiller les molécules indicatives de leurs conditions médicales dans le confort de leur salon. L’efficacité d’une telle stratégie a déjà été validée par des millions de patients diabétiques via l’utilisation du glucomètre. Toutefois, des technologies de détection similaires restent à être développées pour améliorer le traitement de d’autres maladies chroniques. Les capteurs électrochimiques à base d’ADN (capteurs eDNA) ont récemment attiré beaucoup d’attention grâce à leur capacité à détecter plusieurs marqueurs moléculaires dans le sang tout en utilisant un dispositif bon marché et facile d’utilisation. Dans ce type de capteurs, l’ADN est typiquement employé comme élément de reconnaissance ou pour concevoir le mécanisme de signalisation permettant de capturer des cibles moléculaires spécifiques et traduire cet événement de liaison en un signal électrochimique. Des défis particuliers, toutefois, limitent toujours la commercialisation des capteurs eDNA. Par exemple, la plupart de ces capteurs produisent encore d’importantes variations non spécifiques du courant électrique lorsque plongés dans un échantillon de sang. De plus, ces capteurs demeurent sensibles au processus de fabrication et au vieillissement, et nécessitent des modifications chimiques complexes et un long processus d’optimisation pour leur mise au point. L’objectif principal de ma thèse consiste à régler ces limitations via le développement de nouveaux mécanismes de signalisation plus performants. Dans le chapitre 2, nous introduisons un nouveau type de capteurs eDNA basé sur l’hybridation d’ADN que nous avons nommé « essaie d’hybridation électrochimique par encombrement stérique et inhibition rédox (eSHRI) ». Ce mécanisme de signalisation potentiellement universel intègre trois niveaux d’encombrement stérique et un nouveau mécanisme d’inhibition rédox par contact. Nous avons démontré que le eSHRI peut détecter et quantifier de faibles concentrations (nanomolaire) de protéines dans une goutte de sang en moins de 3 min via une diminution de signal électrique allant jusqu’à -93.6 ± 1.36 % du signal initial. De plus, l’essai d’hybridation eSHRI demeure essentiellement indépendant de la densité du brin de capture à la surface de l’électrode et donc insensible aux variations lors de la fabrication et du vieillissement du capteur. Malgré ses caractéristiques impressionnantes, le eSHRI requiert généralement des modifications chimiques complexes pour attacher l’élément de reconnaissance et l’élément rédox à la même extrémité du brin d’ADN. Ainsi, dans le chapitre 3, nous avons développé un nouveau mécanisme de signalisation potentiellement universel, l’essaie de barrière moléculaire, qui nécessite uniquement une modification par brin d’ADN. Dans cet essai, l’élément de reconnaissance et l’élément rédox sont respectivement conjugués à l’ADN de capture (surface de l’électrode) et l’ADN de signalisation (libre en solution). L’essai fonctionne via la formation d’une barrière moléculaire utilisant l’analyte à détecter, une protéine. Lorsque cette dernière se lie à la surface du capteur, cela réduit l’efficacité d’hybridation entre l’ADN de signalisation et l’ADN de capture. En utilisant ce nouveau capteur, nous avons démontré la détection de deux protéines, la streptavidine et un anticorps, directement dans une goutte de sang. Ces dernières années, les anticorps à base d’ADN, nommés aptamères, ont considérablement augmenté notre capacité à détecter des analytes cliniquement pertinents. Toutefois, les capteurs eDNA à base d’aptamères nécessitent un long processus de développement et d’optimisation, et demeurent très dépendants de la densité de surface tout en présentant d’importantes variations de signal lorsqu'ils sont déployés dans le sang. Dans le chapitre 4, nous introduisons un essai simple, hautement modulable et universel qui emploie une chimie dynamique constitutionnelle (CDC) cinétiquement programmée. Cet essai fonctionne en programmant la cinétique de trois réactions concurrentes permettant la détection moléculaire directement dans une goutte de sang. Nous avons démontré que cet essai est potentiellement universel en détectant quantitativement quatre marqueurs moléculaires : la quinine, l’ATP, la thrombine et la PDGF. Nous avons également démontré le potentiel de ce nouveau capteur en exécutant un suivi direct de la quinine dans le sang de souris vivantes. En sommes, nous croyons que ces nouveaux mécanismes de signalisation permettent de résoudre les principales limitations des capteurs eDNA actuels et présentent toutes les caractéristiques pour être développés en dispositifs commercialisables analogues aux glucomètres. / A breakthrough will occur in the healthcare system when patients are allowed to monitor blood molecules indicative of their condition in the comfort of their home. Such an objective has already been realized for diabetic patients through the development of the glucometer. Similar sensors urgently need to be developed to improve the monitoring and treatment of other chronic conditions. Electrochemical DNA-based sensors (eDNA sensors) have recently attracted increasing attention due to their ability to detect multiple blood markers using low-cost and easy-to-use devices. In eDNA sensors, DNA is typically employed either as a recognition element or to design a signaling mechanism that captures specific target molecules and transduces this binding event into an electrochemical signal. Specific challenges, however, limit the commercialization process of eDNA sensors. For example, most eDNA sensors exhibit strong baseline drift when employed in blood, remain sensitive to fabrication processes and aging, and require complex chemical modification and time-consuming optimization processes. The main objective of my Ph.D. project was to solve these limitations through the development of novel improved signaling mechanisms. Chapter 2 introduces a novel hybridization-based eDNA sensing architecture called electrochemical steric hindrance and redox inhibition (eSHRI) hybridization assay. This potentially universal signaling mechanism integrates three levels of steric hindrance and a novel contact redox inhibition mechanism. We have shown that eSHRI can detect low nanomolar concentrations of protein analytes in a drop of blood in less than 3 min with up to -93.6 ± 1.36 % in signal gain. Moreover, the eSHRI hybridization assay remains primarily independent of the sensor density on the surface of the electrode and thus insensitive towards variations in fabrication or aging time. Despite its impressive characteristics, eSHRI may see its universality limited by the complicated chemical modifications required to attach both the recognition element and the redox molecule on the same extremity of a DNA strand. In response, in chapter 3, we develop a novel, potentially universal signaling mechanism, the molecular barrier-based assay, that only requires a single modification of its DNA strands. In this assay, the recognition element and redox molecule are conjugated to the surface-attached capturing DNA and the free-moving signaling DNA. The assay works by having the protein analytes create a molecular barrier upon binding to the sensor surface, reducing the hybridization efficiency between the capturing DNA and the signaling DNA. Using this novel sensor, we have demonstrated the detection of two proteins, streptavidin and antibody, directly in a drop of blood. DNA-based antibodies, called aptamers, have drastically expanded our ability to detect a large proportion of clinically relevant analytes in recent years. However, the development of aptamer-based eDNA sensors still requires a long optimization process, remains highly dependent on specific surface densities, and displays significant signal drift when deployed in the blood. In response, we present in chapter 4 a simple, highly modular, universal assay that employs kinetically programmed constitutional dynamical chemistry (CDC). This assay works by programming the kinetics of three competing reactions to enable molecular detection directly in a drop of blood. We show that this assay is potentially universal by demonstrating the quantitative detection of four molecular markers: quinine, adenosine triphosphate (ATP), thrombin, and platelet-derived growth factor (PDGF). We further show the point-of-care potential of this new sensor by performing direct quinine monitoring in living mouse blood. Overall, we believe that these new sensing mechanisms solve the main weaknesses of current eDNA sensors and display all the characteristics required for the development of commercialized devices analogous to glucose meters.
168

Étude du comportement électromécanique du ventricule gauche canin sous différents modes de stimulation

Vo Thang, Thanh-Thuy 02 1900 (has links)
La thérapie de resynchronisation cardiaque (CRT) est un traitement qui diminue la mortalité et améliore la qualité de vie des patients atteints d’insuffisance cardiaque et présentant un dyssynchronisme de la contraction ventriculaire gauche. Malgré le succès de cette thérapie, plus de 30% des patients ne présentent pas l’amélioration désirée. Plusieurs études portant sur le synchronisme électrique ou mécanique de la contraction ont été effectuées mais peu d’entres elles se sont attardées sur le couplage électromécanique à l'échelle macroscopique. Ce projet a comme objectif d’observer le comportement électromécanique des ventricules canins en présence d’un resynchronisateur cardiaque. Un logiciel a été développé pour permettre l’analyse des informations provenant de la cartographie endocardique sans contact et de la ventriculographie isotopique tomographique chez 12 sujets canins insuffisants. Pour observer la réponse mécanique suite à l’activation électrique, nous avons premièrement recalé les surfaces issues des 2 modalités. Ensuite, nous avons défini les limites du cycle cardiaque, analysé les signaux électriques et les courbes de déplacement de la paroi endocardique. Le début de la contraction est défini par un déplacement radial de 10% vers le centre du ventricule. Les résultats démontrent que la durée d’activation du ventricule gauche et la largeur du QRS augmentent en présence d’une stimulation externe et que les délais électromécaniques sont indépendants dans les modes de stimulation étudiés (sinusal, LVbasal, RVapex ou BIV) avec une moyenne de 84,56±7,19 ms. Finalement, nous avons noté que la stimulation basolatérale procure une fonction cardiaque optimale malgré une durée prolongée du QRS. / Cardiac Resynchronization Therapy (CRT) is known to decrease mortality rate and improve the quality of life for patients suffering from heart failure with left ventricular contraction dyssynchrony. However, it has been shown that 30% of patients do not respond to this therapy. Many studies have investigated the electrical or mechanical synchronism of contraction but few have studied the activation contraction coupling on a macroscopic level. The objective of this study is to observe the left ventricle’s electromechanical behaviour under biventricular stimulation. A software has been developed to analyse the data coming from non-contact mapping and blood pool SPECT for 12 dogs with heart failure. In order to observe the mechanical response following an electrical activation, we have registered 3D surfaces generated by the 2 modalities. Afterward, we defined the cardiac cycle limits, and we analyzed electrical signals as well as endocardial wall displacement curves where the onset of contraction was defined as a 10% inward radial displacement. Results show that both duration of left ventricular activation and QRS increase with pacing and that electromechanical delays are independent of stimulation mode (mean value 84,56 ± 7,19 ms). Finally, we observed that basolateral stimulation shows the best improvement for left ventricular function while presenting a long QRS duration.
169

Production de la voix : exploration, modèles et analyse/synthèse

Hézard, Thomas 09 December 2013 (has links) (PDF)
Ce travail porte sur l'étude de la production de la voix. L'objectif principal est de proposer des solutions pour son analyse-synthèse qui permettent une large représentation de la diversité des signaux biométriques (observés en pratique) dans le cadre du paradigme source-filtre ou de modèles physiques simplifiés. L'étude est menée selon trois axes : l'exploration de l'activité laryngée, la modélisation de la phonation et l'analyse-synthèse sonore. Après une description de l'appareil phonatoire et de modèles d'analyse-synthèse actuels, la première partie s'intéresse à l'exploration de signaux biométriques. A partir du recensement des dispositifs actuels, nous proposons un outil de synchronisation qui révèle la complexité du mouvement 3D des plis vocaux. Une étude comparative avec un système acoustique à valve humaine similaire (lèvres d'un tromboniste) est menée et le développement d'un nouvel outil combinant deux techniques récentes d'imagerie électrique est proposé. Dans la deuxième partie, deux algorithmes d'analyse sont proposés pour un modèle source-filtre fondé sur une représentation tous-pôles causale-anticausale du signal vocal. Un calcul du cepstre complexe est proposé, garantissant l'holomorphie sur une couronne de convergence dans le domaine en Z. Cet outil est alors exploité pour la séparation de la source et du filtre. Enfin, des représentations paramétriques des signaux d'aire glottique sont exploitées pour piloter des modèles à géométrie forcée. Un modèle de synthèse, inspiré du modèle source-filtre mais intégrant l'effet du couplage entre la glotte et le conduit vocal, et des avancées sur la modélisation de conduit vocal à profil régulier sont présentées.
170

Techniques de spectroscopie proche infrarouge appliquées à la quantification de paramètres hémodynamiques

Auger, Héloïse 08 1900 (has links)
Ce mémoire est séparé en deux volets, tous deux axés sur la spectroscopie proche infra-rouge (NIRS) pour la quantification des paramètres hémodynamiques. La NIRS est principalement basée sur la mesure des coefficients d'absorption (μa) et de dispersion (μs’) des tissus afin de retrouver les concentrations d'oxy- et de déoxyhémoglobine dans le sang. L'imagerie à l'aide de la NIRS est basée sur le parcours des photons à travers le tissu biologique à différentes longueurs d'onde du spectre proche infra-rouge. Le premier appareil de NIRS dont il sera question est un appareil de spectroscopie résolue dans le temps. Ce type de système retrouve des concentrations absolues d'hémoglobine à l'aide d'un bandeau placé sur la peau d’un sujet, dans ce cas-ci sur le front. Le modèle d’analyse des données permet la séparation des contributions extra-cérébrales et cérébrales aux données. Cette méthode fournit des données plus exactes sur la saturation en oxygène du cerveau, par rapport à un modèle homogène où le signal est contaminé par les couches superficielles. Une étude sur les changements hémodynamiques cérébraux de jeunes adultes pendant une activité physique a été réalisée, et l’article en détaillant les résultats est transcrit au chapitre 2. Le chapitre 3 comprend un retour sur cette étude et aborde les possibilités de travaux futurs. La seconde partie de mes travaux s’est déroulée sous forme de stage en entreprise durant l’été 2016. Sous la supervision de Dennis Hueber, Ph. D., et Beniamino Barbieri, Ph. D., j’ai effectué des recherches portant sur un appareil de NIRS manufacturé par la compagnie ISS Inc. et dont un prototype se trouve actuellement dans le laboratoire de mon superviseur Mathieu Dehaes, Ph. D. Cet appareil combine deux modalités d’imagerie optique, soit la NIRS dans le domaine des fréquences et la spectroscopie de corrélation diffuse. Le chapitre 4 détaille les tâches que j’ai réalisées durant ce temps, de même que les résultats des analyses que j’ai effectuées. / This master’s thesis is separated in two phases, both focused on near infrared spectroscopy for the quantification of hemodynamic parameters. NIRS is based on the measure of absorption (μa) and scattering (μs’) coefficients of tissues in order to recover the oxy- and deoxyhemoglobin concentrations in the blood. Its results are based on the photon propagation in tissue at different near-infrared wavelengths. The first NIRS system used during my studies is a time-resolved spectroscopy system. This device allowed us to retrieve absolute hemoglobin concentrations using a headband placed over the subject’s skin and centered on their forehead. The data analysis model which we used allowed us to separate extra-cerebral and cerebral contributions of the signal. This method yielded quantitative absolute measures of cerebral oxygen saturation as opposed to the traditional homogenous model where the signal is contaminated by superficial layers. A study on cerebral hemodynamic changes in young adults during exercise was conducted, and the published article detailing its results is transcribed in Chapter 2. Chapter 3 includes a review of this study and discusses potential future works. The second part of my research consisted in an industrial internship during the summer of 2016. Under the supervision of Dennis Hueber, Ph. D., and Beniamino Barbieri, Ph. D., I have worked on a NIRS device manufactured by ISS Inc., a prototype of which is currently in the laboratory of my supervisor Mathieu Dehaes, Ph. D. This device combines two NIRS modalities: frequency-domain NIRS and diffuse correlation spectroscopy. Chapter 4 details the work I have performed at ISS and the results of my research and analysis.

Page generated in 0.0733 seconds