• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 316
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 318
  • 207
  • 65
  • 64
  • 61
  • 56
  • 54
  • 53
  • 49
  • 47
  • 47
  • 45
  • 42
  • 37
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Comparação biomecânica do canto póstero-lateral do joelho com e sem reconstrução: estudo em cadáveres / Biomechanic comparison of posterolateral corner of the knee with and without reconstruction. Study in cadavers

José Wilson Serbino Junior 26 July 2007 (has links)
O objetivo desta dissertação foi avaliar biomecanicamente o papel da aplicação de uma técnica cirúrgica utilizando os tendões dos músculos semitendíneo e grácil na reconstrução anatômica de lesão criada no canto póstero-lateral do joelho. Foram estudados 10 joelhos de cadáveres nas situações intacto, lesado, parcialmente reconstruído e reconstruído. As principais estruturas do canto póstero-lateral do joelho foram seccionadas para criar o padrão de lesão. Os momentos de força aplicados foram 2 N.m e 5 N.m, com o joelho a 0º, 30º, 60º ou 90º de flexão. Foi também calculada a rigidez do joelho em cada uma das situações nas diferentes posições testadas. Os ensaios foram realizados em dispositivo criado no Laboratório de Biomecânica LIM-41 da Faculdade de Medicina da USP, e os dados de deformação angular foram obtidos através de programa de fotogoniometria. Os resultados obtidos foram submetidos a análise estatística pela Análise de Variância para Experimento em Blocos Aleatorizados e os tratamentos foram comparados entre si pelo método de Scheffé. Foi possível concluir que: 1) A técnica empregada não corrigiu completamente o aumento da rotação externa. 2)A técnica empregada restaurou a estabilidade em varo. / The purpose of this study was to evaluate the application of a surgical technique for anatomical reconstruction of the structures from the posterolateral corner of the knee. We tested 10 cadaver knees with intact, ruptured, partially reconstructed and reconstructed ligaments. The main posterolatreal structures were cut to produce a lesion pattern. The applied force moments were of 2 N.m and 5 N.m with the knee flexed to 0, 30, 60 and 90 degrees. The stiffness of the knee in each of these situations at the studied angles was also determined. The assays were carried through in a device created at the Laboratory of Biomechanics LIM-41 from of the University of São Paulo School of Medicine. Data from the angular deformation were obtained through a photographic measurement aided by computer software. The results were submitted to ANOVA and the treatments had been compared using statistical method of Scheffé. It was possible to conclude that: 1) The technique employed wasn?t able to restore normal external rotation. 2) The technique employed restored varus stability.
162

Análise cinemática da articulação do joelho durante a marcha hemiparética / Análise cinemática da articulação do joelho durante a marcha hemiparética

Paulo Roberto Garcia Lucareli 02 July 2004 (has links)
Ainda não há consenso entre os diversos estudiosos do tema sobre as variáveis cinemáticas das articulações durante a marcha hemiparética e uma das articulações mais discutidas é o joelho: como as principais alterações se comportam ao longo do ciclo de marcha e se a velocidade da marcha modifica os padrões de mobilidade das articulações. O objetivo deste estudo foi avaliar as variáveis encontradas na cinemática angular da articulação do joelho e descrever as alterações encontradas na marcha hemiparética oriunda de acidente vascular cerebral. Participaram deste estudo 66 pacientes adultos de ambos os sexos com diagnóstico de seqüela de acidente vascular cerebral isquêmico com hemiparesia direita ou esquerda. Todos os participantes foram submetidos a avaliação tridimensional da marcha com o sistema Vicon 370 e os valores da cinemática angular da articulação do joelho foram selecionados para análise. Os resultados foram distribuídos em quatro grupos formados de acordo com a mediana da velocidade de marcha e lado do acometimento. As características clínicas relevantes encontradas e que devem ser levadas em consideração no momento da escolha da melhor conduta de tratamento demonstram no apoio alteração importante no mecanismo de resposta a carga e hiperextensão do joelho no apoio simples. Na fase de balanço redução do pico de flexão e amplitude de movimento do joelho. Há semelhança na cinemática angular da articulação do joelho durante a marcha hemiparética oriunda de acidente vascular cerebral, mas, não foi encontrado um padrão definido para esta articulação na população avaliada / There is still no consensus among the different specialists on this subject on the kinematics variation during the hemiparetic gait, and one of the most frequently discussed joints is the knee: the way the main changes take place during the gait cycle, and whether the gait velocity changes the patterns of joint mobility. This study aims at evaluating the variables found in the angular kinematics of the knee articulation and at describing the alteration found in the hemiparetic gait resulting from cerebrovascular accident. This study comprised 66 adult patients, both gender with diagnosis of a sequel resulting from ischemical cerebrovascular accident with both right and left hemiparesis. All the participants were submitted to three-dimensional gait evaluation with Vicon 370 and the values of the angular kinematics of the joint knee were selected for analysis. The results were distributed in four groups formed in agreement with the medium of the gait speed and side taken. The clinical relevant characteristics found and that should be taken into account when choosing the best treatment demonstrate, in the stance, an important mechanism of loading response and, in the simple stance, knee hyperextension. In the swing phase, reduction of the peak flexion and movement amplitude of the knee. We believe that our findings presented here may aid the conduct when facing these patients in the sense of preventing the occurrence of problems found, and also in the attempt of finding the origin of these problems
163

Análise cinemática do tronco, quadril e joelho durante a realização de diferentes tarefas funcionais para avaliação do valgo dinâmico / Kinematic analysis of the trunk, hip and knee during the execution of different tasks to evaluate the functional dynamic valgus

Ana Cristina Corrêa Cervi 24 January 2017 (has links)
Um dos fatores que podem contribuir para as lesões na articulação do joelho é a incapacidade do indivíduo em manter durante atividades funcionais, um bom alinhamento entre os segmentos corporais tais como tronco, quadril e joelho. Na maioria das vezes o aumento do valgo dinâmico de joelho é apontado como um fator etiológico de lesões nessa articulação e sua identificação precoceé importante, bem como de outros fatores biomecânicos. Os testes funcionais para avaliação do valgo são importantes ferramentas para analisar o alinhamento dinâmico entre os segmentos corporais, porém ainda não há na literatura subsídios cinesiológicos que comparem a amplitude articular do joelho, quadril e tronco nas principais tarefas funcionais e utilizadas na prática clínica. Da mesma forma, a relação da cinemática desses segmentos com o torque dos músculos estabilizadores do quadril e joelho ainda é controverso. Objetivos: Comparar os valores angulares dados pela cinemática de tronco, quadril e joelho em cinco diferentes tarefas funcionais utilizadas para avaliação do valgo dinâmicoe correlacionar com o pico de torque de joelho e quadril. Materiais e Métodos: 30 voluntários saudáveis sem historia de dor ou disfunção em membros inferiores, de ambos os sexos (15 homens e 15 mulheres) com idade de 18 a 35 anos realizaram os testes de força muscular isométrica para todos os grupos musculares de joelho e quadril utilizando o Dinamômetro isocinéticoBiodex®. Entre 3 a 7 dias após o teste de força muscular foi realizada a análise cinemática de tronco, quadril e joelho utilizando o Sistema VICON (Centennial, CO, EUA) durante a realização de cinco diferentes tarefas funcionais para avaliação do valgo dinâmico de joelho, sendo elas: descida de degrau, singlelegstepdown, agachamento unipodal, aterrissagem unipodal, drop vertical jump. Resultados: A tarefa dedrop vertical jump apresentou os maiores valores de pico de valgo(média: 20,1º p<=0,04), rotação interna de joelho(média: 9,7º p<=0,003), flexão de quadril(média: 38,8º p<=0,001) e menores valores de rotação de tronco (média: 0,07º p<=0,009). A tarefa de single legstepdown apresentou maiores valores de flexão de tronco (média: 10,2º p<=0,002) em relação às outras tarefas funcionais. Foi observada uma correlação negativa e fraca do pico de torque de rotadores externos de quadril e inclinação ipsilateral de tronco(R= - 0,36; p=0,049) na tarefa de descida de degrau. Não houve evidências de correlação entre o pico de torque de abdutores, adutores, rotadores internos,rotadores externos, flexores, extensores de quadril e flexores e extensores de joelho com a cinemática de joelho, quadril e tronco nas tarefas funcionais de agachamento unipodal, aterrissagem unipodal, drop vertical jump e singlelegstepdown. Conclusão:A compreensão das variáveis cinesiológicas de joelho, quadril e troncoé fundamental para direcionar o clínico na escolha do teste funcional para avaliação do valgo dinâmico.Todas as tarefas analisadas são efetivas para avaliar o valgo dinâmico, porém adrop vertical jumpparece demandar mais estratégias de joelho e quadril, e a tarefasingle legstepdown apresentou maiores alterações cinesiológicasde tronco. Além disso, o pico de torque de quadril e joelho não exerceu influência no desempenho dos testes em indivíduos saudáveis / One of the factors that can contribute to injuries in the knee joint is the individual\'s inability to maintain an alignment between the body segments such as trunk, hip and knee during functional activities. Most of the time the dynamic knee valgus has been suggested as an etiologic factor that contributefor this joint injuries and early identification along with biomechanical factors associated with knee joint injuries is important. The functional tests for knee valgus evaluation are important tools for assessing the dynamic alignment between body segments, but there is no kinesiological subsidies in the literature that compare knee, hip and trunk in most of the described functional tasks used in the clinical practice and their relationship with the hip and knee strengthin healthy subjects. This study aimsto compare the angle values by the trunk, hip and knee kinematics in five different functional tasks used to evaluate the dynamic valgus and correlate this with the muscle\'s torque of the hip and knee. A sample of 30 healthy volunteers (15 men and 15 women) aged 18 to 35, with no history of pain or dysfunction in the lower limbs, performed a isometric muscle strength tests for all theknee and hip groups muscles using an isokinetic dynamometer Biodex®. Between 3 and 7 days after the muscle strength testing trunk, hip and knee kinematic analysis was performedduring five different functional tasks for evaluating the dynamic knee valgus using the Vicon system (Centennial, CO, USA).The functional tests were: stair descent, single-leg step down, single leg squat, single leg landing, drop vertical jump. ANOVA repeated measures was used to verify the differencesin the tasks for knee, hip and trunk kinematics and Pearson\'s correlation was used to verify correlations between hip and knee muscle\'s torque and knee, hip and trunk kinematics. The drop vertical jump task showed the highest peak values of valgus (average: 20.1º p<=0,04), internal rotation of the knee (average: 9,7º p<=0,003), hip flexion (mean: 38,8º p<=0,001) and lower trunk rotation values (mean 0,07º p<=0,009). The single leg step down task showed greater trunk flexion values (mean: 10,2º p<=0,002) in relation to all functional tasks. It was observed a negative and weak correlation of thehip external rotators torque and ipsilateral trunk lean (R = - 0.36, p = 0.049) in stair descent task. There was no evidence of correlation between peak torque of the hip abductors, adductors, internal rotators, external rotators, flexors and extensors and flexors, extensors of the knee with knee, hip and trunk kinematics in the single leg squat, landing, drop vertical jump and single-leg step down. For choosing a functional task to evaluate the dynamic valgus is crucial to the clinicians understand the kinesiological variables of knee, hip and trunk. All assessed tasks are effective to evaluate the dynamic knee valgus, although the drop vertical jump task requires more adjustments in the knee and hip, and the single leg step down task has higher kinesiological changes in the trunk.In addition, knee and hip peak of torque had no influence on the performance of the tests in healthy individuals
164

Análise cinemática e baropodométrica de tornozelo e pé durante diferentes tarefas funcionais para avaliação do valgo dinâmico de joelho / Kinematic analysis of the ankle and foot during different functional tasks to evaluate the dynamic value of knee

Diego José Argenton Telarolli 26 May 2017 (has links)
O valgo dinâmico de joelho é amplamente relacionado à disfunção e ao mau alinhamento postural e membros inferiores. No entanto, não está estabelecido como o valgo dinâmico de joelho está associado às adaptações cinemáticas de tornozelo e pé e ao comportamento das cargas plantares durante atividades funcionais. Objetivo: Comparar a amplitude articular de dorsiflexão do tornozelo, adução e abdução de retropé, pronação e supinação de subtalar, bem como avaliar a área e a pressão plantar total e do mediopé em diferentes tarefas funcionais utilizadas na avaliação do valgo dinâmico de joelho em indivíduos clinicamente saudáveis de ambos os sexos a partir da avaliação cinemática e baropodométrica. O objetivo foi correlacionar o valor do pico de valgo dinâmico de joelho com as amplitudes de tornozelo, com a área e pressão plantar do pé nestas tarefas. Materiais e métodos: Foram incluídos 30 voluntários sem histórico de lesão ou trauma nos membros inferiores, sendo 15 homens e 15 mulheres. Os voluntários tiveram o membro inferior dominante avaliado na realização de cinco diferentes tarefas funcionais: descida de degrau, single leg step down, agachamento unipodálico, aterrissagem unipodálica e drop vertical jump. Para a avaliação cinemática foi utilizado o sistema Vicon (Centennial, CO, EUA) com um total de 34 marcadores refletivos bilateralmente, para observação das variáveis cinemáticas tridimensionais de joelho, tornozelo e pé. A área e a pressão plantar foram obtidas do Baropodômetro Matscan System (Tekscan®. South Boston, MA, EUA). Para as análises dos dados cinemáticos e baropodométricos foram considerados o momento do pico de valgo de joelho nas diferentes tarefas funcionais realizadas. Resultados: As amplitudes de dorsiflexão de tornozelo (P = 0,489), adução e abdução do retropé (P = 0,0791), pronação e supinação de retropé (P = 0,163) e pronação e supinação da articulação subtalar (P = 0,305) não foram diferentes entre nenhuma das tarefas realizadas. Quanto as variáveis de área e pressão plantar total do pé, as tarefas de agachamento unipodálico e a descida de degrau apresentaram os maiores valores em comparação as tarefas de aterrissagem unipodálica (p = 0,005 e 0,027; ES = 0,66), drop vertical jump (p = 0,001 e p = 0,001; ES = 0,38) e single leg step down (p = 0,01 e p = 0,007; ES = 0,43). Os menores valores foram observados na tarefa de drop vertical jump com diferenças observadas para todas as tarefas (p<0,05). Já para as variáveis de pressão plantar do mediopé, a maior pressão foi observada na tarefa de descida de degrau que foi diferente de todas as tarefas (p<0,005), exceto a tarefa de agachamento unipodálico (p=0,13 es= 0,306) e as menores pressões foram encontradas na tarefa do drop vertical jump que apresentou diferenças para a tarefa de agachamento unipodálico (p=0,028 es= 0,485), aterrissagem unipodálica (p=0,006 es= 0,687) e descida de degrau (p=0,001 es= 0,257), porém não apresentou diferenças quando comparada a tarefa de single leg step down (p=0,374 es= 0,170). As variáveis de pico de valgo dinâmico de joelho apresentaram baixa correlação com as variáveis de pronação da articulação subtalar, área e pressão total e do mediopé. Conclusão: As tarefas funcionais avaliadas não apresentam diferença na cinemática de tornozelo e pé. A tarefa de descida de degrau levou a uma maior área de contato e maior pressão plantar do pé e a tarefa de drop vertical jump apresentou menor área de contato e menor pressão plantar do pé. Não houve correlação do pico de valgo dinâmico de joelho, com as amplitudes de tornozelo e pé, bem como a área e a pressão plantar do pé. / Dynamic knee valgus is largely related to the dysfunction and poor postural alignment of this articulation. However, isn\'t established how dynamic knee valgus can be associated with ankle and foot kinematic adaptations and the behavior of the plantar loads during functional activities. Objective: To compare the joint amplitude of ankle dorsiflexion, adduction and abduction of rearfoot, pronation and supination of midfoot, as well as to evaluate the total and midfoot area and pressure in different functional tasks used in the evaluation of dynamic knee valgus in clinically healthy individuals of both sexes from the kinematic and baropodometric evaluation. Besides that, the goal was to correlate the value of the dynamic knee valgus peak with the ankle amplitudes, with the foot area and foot pressure in these tasks. Materials and methods: It included 30 volunteers with no history of injury or trauma in the lower limbs, 15 men and 15 women. The volunteers had the dominant lower limb evaluated in performing five different functional tasks: step descent, single leg step down, single leg squat, unipodal landing and drop vertical jump. For the kinematic evaluation, the Vicon system (Centennial, CO, USA) with a total of 34 markers were used bilaterally to observe the three-dimensional knee, ankle and foot kinematics variables. The area and plantar pressure were obtained from the Matscan System Baropodometer (Tekscan®, South Boston, MA, USA). For the analysis of the kinematic and baropodometric data, the moment of the knee valgus peak was considered in the different functional tasks performed. Results: Results: The amplitudes of ankle dorsiflexion (P = 0.489), adduction and abduction of the rearfoot (P = 0.0791), pronation and supination of the rearfoot (P = 0.163) and pronation and supination of the subtalar joint (P = 0.305) did not Were different between any of the tasks performed. Regarding the variables of area and total foot pressure of the foot, the tasks of unipodal squatting and stair descent presented the highest values in comparison to the tasks of unipodal landing (p = 0.005 and 0.027; ES = 0.66), drop vertical jump (P = 0.001 and p = 0.001, ES = 0.38) and single leg step down (p = 0.01 and p = 0.007, ES = 0.43). The lowest values were observed in the drop vertical jump task with differences observed for all tasks (p <0.05). For the midfoot plantar pressure variables, the greatest pressure was observed in the task of stair descent that was different from all tasks (p <0.005), except for the one-legged squat task (p = 0.13 and 0.306) (P = 0.028 es = 0,485), unipodal landing (p = 0,006 es = 0,687), and lowering of the step (p = 0.001 es = 0.257), but did not present differences when compared to single leg step down task (p = 0.344 es = 0.170). The variables of dynamic knee dynamic valgus presented a low correlation with the variables of pronation of the subtalar joint, area and total pressure and midfoot.Conclusion: The functional tasks evaluated don\'t present differences in ankle and foot kinematics. The task of step descent led to a greater area of contact and greater plantar pressure and the task of drop vertical jump had a lower area of contact and lower foot pressure of the foot. There was not a correlation of the dynamic knee valgus peak with the ankle and foot amplitudes, as well as foot area and pressure.
165

Análise cinemática e eletromiográfica de testes funcionais de instabilidade dinâmica de joelho / Kinematic and electromyographic analysis in functional testing of dynamic knee instability

Fábio Pamplona Mariano 08 April 2016 (has links)
O objetivo da presente dissertação foi avaliar e comparar o comportamento da movimentação do joelho, nos testes Drop Vertical Jump (Drop), Single Hop (Hop), Triple Hop (Triplo), Cross-over Hop (Cross), Six-Meter Timed Hop (6M) e Sidestep Cutting (Sid), através de análises cinemáticas das rotações e velocidades angulares do joelho, e pela co-ativação muscular do membro inferior, em jogadoras de handebol. O desenho experimental da pesquisa foi um estudo transversal, na qual foram avaliadas 12 participantes (idade média de 21,2±2,4 anos, massa corporal média de 68,9±10,3kg e estatura média de 1,70±0,04m). Antes das avaliações, todas foram demarcadas com 25 marcadores retrorefletivos em proeminências ósseas de interesse. Além disso, foram acoplados 10 sensores de eletromiografia (EMG) (EMG TrignoTM Wireless System), nas musculaturas do reto femoral, bíceps femoral e glúteo médio. Após foram aplicados os seis testes funcionais, em três tentativas válidas com o membro dominante. Os dados da cinemática foram obtidos pelo sistema de captura de movimento VICON (Centennial, CO, EUA) e analisados por rotinas desenvolvidas no software MatLab (Mathworks Inc., Natick, MA, USA). Os ângulos de rotação do joelho, especificamente o valgo do joelho, foram obtidos pelos Ângulos de Euler. Já as velocidades angulares escalares foram geradas pelo quatérnion unitário. E por último, as razões de co-ativação entre o reto femoral/bíceps femoral (RB) e reto femoral/glúteo médio (RG) foram através do sinal da integral normalizada da EMG. A partir disso, foram traçados os momentos das variáveis em cada teste avaliado. Para os ângulos de valgo foram extraídos os valores no contato inicial (CI), 40 e 100 ms após o CI, na flexão máxima (Flexmax) e no valgo máximo do joelho (Valgomax). Para as velocidades angulares foram os mesmos instantes, mais o momento de velocidade positiva (Velpos) e velocidade negativa (Velneg). Para as co-ativações foram os mesmos instantes dos ângulos, mais o momento da força pico de reação do solo (FPRS), por duas plataformas de força (Columbus, EUA). Nos ângulos de valgo houve interação [F(2,220)=11,456; p<0,001] na comparação (momento x testes) revelando diferenças significativas nas comparações pareadas. No CI, no 100ms e na Flexmax o Sid apresentou diferença para quase todos os outros testes, assim como o Drop na Flexmax. Nas velocidades angulares houve interação [F(30,330)=14,476; p<0,001] com diferenças significativas nas comparações pareadas. Nos instantes de 40ms, 100ms, Velpos e Velneg o Drop apresentou diferença para quase todos os testes, assim como o 6M apontou diferença para todos os outros testes no 100ms e Velneg. Houve ainda relação moderada: do Cross no momento de Valgomax nas variáveis ângulo de valgo e a velocidade angular (p=0,032); do Sid no momento 40ms nas variáveis do ângulo de valgo e a coativação RB (p=0,015); e no Hop no momento 100ms nas variáveis de ângulo de valgo e a coativação RG (p=0,029). Contudo, pode-se concluir que os testes funcionais de instabilidade dinâmica do joelho para as variáveis cinemáticas apresentam comportamentos específicos. Além disso, ficou demonstrado que o aumento do valgo do joelho no Cross é influenciado pela rapidez da velocidade angular. Podemos concluir ainda, que a adaptação neuromuscular RB, no Sid - 40ms, sofre a influência direta do ângulo de valgo, e que o sinergismo de RG, no Hop - 100ms, é fundamental para o controle do ângulo de valgo do joelho / The objective of this thesis was evaluate and compare the knee movement behavior, in the tests Drop Vertical Jump (Drop), Single Hop Test (Hop), Triple Hop Test (Triple), Cross-over Hop Test (Cross), Six-Meter Timed Hop Test (6M) e Sidestep Cutting (Sid), through rotation and knee angular speed kinematic analysis, and by the low member muscles co-activation, in female handball players. The experimental research design was a cross-sectional in which were evaluate 12 participants in the average age of 21.2±2.4, average body mass of 68.9±10.3kg and average height of 1.70±0.04m. Before the evaluation all made a 5 minutes warm-up and marked with 25 reflective markers in bony prominences of interest for further kinematic analysis. Besides that, where attached 10 electromyography sensors (EMG TrignoTM Wireless System), recto-femoral muscles, femoral biceps and gluteus medium. After the volunteer preparation where evaluated the six functional tests Drop, Hop, Triple, Cross, 6M and Sidestep Cutting in three valid attempts with the dominant limb. The kinematic data where obtained by the movement capture system VICON (Centennial, CO, EUA) and analyzed by the developed routines using the software MatLab (Mathworks Inc., Natick, MA, USA). The knee rotation angle, specifically the knee valgus, where generated by the sequences of Euler rotation angle. The scalar angular speeds where drawn by unitary quaternion. Finally, the co-activation ratios between the recto-femoral/femoral biceps (RB) and recto-femoral/gluteus medium (RG) where normalized integral sign by EMG. From this where set the variables moments in each evaluated test. To the valgus angle where extracted the initial contact values (CI) through a force platform (Columbus, EUA), 40ms and 100ms after the CI, in maximum flexion (Flexmax) and maximum knee valgus (Valgomax). To angular speeds where the same moments plus the positive speed momentum (Velpos) and negative speed momentum (Velneg). To the co-activation where used the same angle moments plus the moment of force peak ground reaction (FPRS). In the valgus angle there was interaction [F(2,220)=11,456; p<0,001] comparing (moment x tests) revealing significant differences in pairwise comparison. In CI, on 100ms and Flexmax the Sid presented difference to all most all the other tests likewise the Drop on Flexmax. In the angular speed there was the interaction [F(30,330)=14,476; p<0,001] with significant differences in pairwise comparison. In the moment 40ms, 100ms, Velpos and Velneg the Drop presented differences to all most all the other tests likewise the 6M pointed differences to all the other 100ms and Velneg tests. There was also a moderated relation from: Cross in the Valgomax moment in valgus angle variables and angle speed (p=0,032); Sid in 40ms moment the valgus angle variables and the co-activation (p=0,015); Hop in 100ms moment the valgus angles variables and co-activation RG (p=0,029). We can conclude that the knee dynamics instability functional tests in the dynamic valgus critical moments analysis, show that the valgus angle variables and angular velocity specific behaviors in the tests applied. Besides that was established that the knee valgus increase in Cross is influenced by the speed of angular velocity. Also can be concluded that the neuromuscular adaptation RB in SID - 40ms, has a direct influence of valgus angle and the synergism of Hop - 100ms, is fundamental to the knee valgus angle control
166

Avaliação da estabilidade postural em indivíduos portadores de hiperextensão dos joelhos / Evaluation of postural stability in subjects with knee joint hyperextension

Cassio Marinho Siqueira 14 August 2008 (has links)
Acredita-se que o alinhamento postural interfira no controle postural. Entretanto, a literatura científica a respeito desta interação é escassa e controversa. Alguns autores relataram baixa ou nenhuma correlação entre alinhamento e controle postural enquanto outros autores relataram alta correlação. Esta questão foi abordada através da avaliação da estabilidade postural em indivíduos portadores de hiperextensão dos joelhos, uma alteração do alinhamento postural predominantemente do plano sagital e que, portanto, deve interferir principalmente no deslocamento ântero-posterior do centro de pressão (CP). Além disto, esta condição postural pode ter implicações funcionais e está relacionada a um maior risco de lesões do joelho. Os objetivos deste trabalho foram avaliar os efeitos do desalinhamento postural do joelho sobre a estabilidade postural através de parâmetros do centro de pressão e os efeitos da perturbação visual e proprioceptiva sobre o alinhamento postural dos joelhos durante a postura bípede quieta. Dados cinemáticos foram adquiridos a partir do lado direito de 23 mulheres adultas, jovens e saudáveis enquanto permaneciam em postura bípede quieta sobre uma plataforma de força modelo AMTI. Três tentativas de 30 segundos foram efetuadas em cada uma de quatro condições sensoriais nas quais os sujeitos permaneciam de pé diretamente sobre a plataforma de força (PLAT) ou sobre uma placa de espuma posicionada sobre a plataforma de força (ESPUMA) com os olhos abertos (OA) ou fechados (OF). Os sujeitos foram enquadrados nos grupos Sujeito- Hiperestendido (n=14) e Sujeito-Alinhado (n=9) de acordo com o alinhamento dos joelhos na avaliação postural tradicional e a análise dos dados cinemáticos foi efetuada. Uma vez que o ângulo dos joelhos variou através das tentativas em condições com distúrbios sensoriais, uma nova classificação dos grupos baseada no ângulo dos joelhos de cada tentativa foi efetuada para a análise dos dados cinéticos. Três grupos foram utilizados nesta análise: Grupo Tentativa-Alinhada, Grupo Tentativa-Hiperestendida e Grupo Tentativa-Ajustada, este último compreendendo as tentativas em que o ângulo do joelho permanecia o tempo todo inferior a 180o, mas de sujeitos inicialmente classificados como tendo joelhos hiperestendidos. Os resultados mostram que o Grupo Sujeito-Hiperestendido teve uma clara tendência a flexionar e aumentar a amplitude de movimento dos joelhos a medida que o desafio ao equilíbrio aumentou. A comparação dos dados cinéticos entre os grupos mostrou diferenças significativas na velocidade média de deslocamento do CP nas condições PLAT/OA e ESPUMA/OF. Conclui-se que os indivíduos com hiperextensão dos joelhos respondem aos distúrbios sensoriais com flexão e aumento da amplitude de movimento dos joelhos. E, mesmo quando apresentam ângulos dos joelhos similares aos dos sujeitos com joelhos alinhados, apresentam maior atividade regulatória da postura representada pela maior velocidade média do CP. / Postural alignment is thought to affect postural control. Data describing the relationships between postural alignment and stance stability are scarce and controversial. Some authors reported no correlation or low correlation between postural alignment and stance stability while others reported high correlations. This matter was approached by evaluating stance stability in individuals with hyperextended knees which is a condition with functional implications and related to an increased risk of knee injuries. Also, this condition is mainly a sagittal plane misalignment that might affect predominantly the center of pressure displacement in anterior-posterior axis. The purpose of this study was to evaluate the effects of postural misalignment of knees in stance stability and the effects of sensorial disturbances on knee postural alignment. Kinematic data were collected from the right side of 23 healthy female adults while quietly standing on an AMTI force plate. Three trials of 30 seconds were performed in each of four conditions when subjects stood directly on the force plate (PLATE) or on a slab of foam (FOAM) with eyes open (EO) or eyes closed (EC). Subjects were classified into Aligned-Subjects Group (n=9) and Hyperextended-Subjects Group (n=14) based on traditional postural evaluation, and kinematic analysis was performed. Because knee angles changed throughout trials in conditions with sensorial disturbances, a new classification of groups based on knee angles in each trial was needed in order to analyze kinetic variables. Three groups were used in this analysis: Aligned-Trials Group, Hyperextended-Trials Group and Adjusted-Trials Group. The latter contained the trials in which knee angles were lower than 180o of subjects that showed initially hyperextended knees. Results show that the hyperextended group had a clear tendency to flex their knees and to increase knee motion as balance challenge increased. Comparison of center of pressure (COP) variables among the groups showed differences in mean velocity in the PLATE/EO and FOAM/EC conditions. It was concluded that subjects with knee hyperextension exhibited a motor strategy by flexing their knees in challenging conditions and even when showing knee angles similar to those of aligned subjects, their stance stability showed a higher mean velocity of COP
167

Avaliação dos fatores associados à extrusão meniscal no compartimento femorotibial medial na presença e na ausência da carga corpórea / Evaluation of the factors associated with meniscal Medial femorotibial compartment in the presence and absence of body weight

Everaldo Gregio Júnior 03 February 2016 (has links)
Introdução: As alterações meniscais causadas por lesões degenerativas ou traumáticas podem levar a importantes alterações na estrutura dos mesmos. Pouco se sabe sobre o efeito direto da carga corpórea nos compartimentos femorotibiais sobre os diferentes graus de extrusão meniscal. Objetivos: Avaliar a extrusão meniscal no compartimento femorotibial medial, nas posições em decúbito e ortostática, por meio da ultrassonografia (US). Avaliar o desempenho da US na avaliação meniscal na posição em decúbito, usando a ressonância magnética (RM) como padrão de referência. Material e Métodos: 104 indivíduos com dor crônica no joelho realizaram exames de ultrassonografia e ressonância magnética. Dois radiologistas avaliaram a extrusão meniscal por US e RM e a graduaram:0 (< 2 mm), 1 (>= 2 mm and < 4 mm), and 2 (>= 4 mm).Um avaliador realizou a mensuração da extrusão meniscal dos indivíduos nas posições em decúbito dorsal e ortostática, e para avaliar os efeitos dessas medidas foi utilizada a correlação intraclasse (CIC) e teste pareado de Wilcoxon. Para comparar os resultados obtidos pela mensuração entre grupos com presença e ausência de lesão foi utilizado o teste T não pareado, com p <0,05 considerado como significativo. Resultados: Houve concordância substancial entre os examinadores quando comparadas a avaliação entre US e RM (CIC: 0,73 e 0,70). O US mostrou excelente sensibilidade (95% e 96%, cada examinador) e boa especificidade (82% e 70%, cada examinador). Houve diferença significativa dos valores médios de extrusão meniscal entre as posições em decúbito e ortostase (p = 0,0002). Todos os meniscos com extrusão >= 3 mm pela US apresentavam lesão meniscal confirmada pela RM (p< 0,0001). Conclusão: A avaliação de extrusão meniscal via US mostra excelente desempenho diagnóstico. Há variação na extrusão do menisco medial entre as posições decúbito e ortostase, com maior extrusão na posição ereta. / Background: Meniscal abnormalities related to degenerative or traumatic lesions may lead to significant changes in meniscal structure. There is lack knowledge about the direct effect of weight bearing in femorotibial compartments on the diverse meniscal extrusion levels. Objectives: To evaluate meniscal extrusion on medial femorotibialcompartmentby ultrasonography (US), both in dorsal decubitus and orthostatic positions. To evaluate US performance inassessment of meniscus in dorsal decubitus, using magnetic resonance (MR) as a standard method. Material andMethods: A total of 104 subjects with chronic pain on the knee underwent US and MR. Meniscal extrusion was assessed by two radiologists using US and RM, being graded as: 0 (< 2 mm), 1 (>= 2 mm and < 4 mm), and 2 (>= 4 mm). One radiologist performed measurements of meniscal extrusion of the participants in dorsal decubitus and orthostatic positions. Intra-class coefficient (ICC) and Wilcoxon paired t-test were used to analyze the effects of such measurements. To compare data from groups with and without lesions we used non-paired t-test was used, with values of p < 0,05considered to be significant. Results: There was substantial agreement between readers when US and MR evaluations were compared (ICC: 0,73 e 0,70). US showed excellent sensitivity (95% e 96%, each reader) and good specificity (82% e 70%, each reader). There was significant difference onmedium values of meniscal extrusion regarding dorsal decubitus and orthostatic positions (p = 0,0002). All subjects that presented meniscal extrusion >= 3 mm on US had meniscal lesion confirmed by RM (p < 0,0001). Conclusion: US has an excellent diagnostic performance in assessment of meniscal extrusion. Meniscal extrusion varies from dorsal decubitus and orthostatic positions, being higher while in upright position.
168

Protocolo de captação, processamento e transplante de enxertos osteocondrais homólogos a fresco na articulação do joelho / Protocol of procurement, processing and transplantation of fresh osteochondral allografts in the knee joint

Luís Eduardo Passarelli Tirico 07 April 2015 (has links)
O tratamento das lesões condrais e osteocondrais do joelho em pacientes jovens ainda permanece um desafio para os médicos ortopedistas. As técnicas de reparo destas lesões atualmente disponíveis no Brasil, como desbridamento, microfraturas e transplante osteocondral autólogo são insuficientes nos tratamentos das lesões condrais e osteocondrais maiores do que 4 cm2. O transplante osteocondral homólogo a fresco (TOF) na articulação do joelho vem sendo usado em outros países com excelentes resultados. Até o presente momento não existem relatos da utilização desta técnica no Brasil, fato que dificulta o tratamento de pacientes jovens ativos que necessitam de reparo biológico. Foram incluídos neste estudo oito pacientes de 15 a 45 anos portadores de lesões osteocondrais maiores que 4 cm2. Os enxertos a fresco foram obtidos de doadores de órgãos, sendo a articulação do joelho captada sem violação da cápsula articular e transportada ao Banco de Tecidos para processamento. O pareamento doador e receptor foi realizado conforme o tamanho, a localização e a prioridade em lista de espera de acordo com os tecidos captados, sendo os mesmos armazenados no meio de preservação Ham F-12 - GIBCO com glutamax (Invitrogen, Life Technologies, Estados Unidos) e com antibióticos. O procedimento cirúrgico foi realizado pelas técnicas de cilindro osteocondral e de superfície, sendo fixados quando necessário. Os pacientes foram avaliados através dos questionários de IKDC objetivo, IKDC subjetivo, KOOS e índice de Merle D\'Aubigne e Postel modificado. Foram realizados oito TOFs de março a outubro de 2012. A média de idade dos pacientes transplantados foi de 30,1 anos (17- 44 anos) e a média da área transplantada foi de 10,6 cm2 (4,6 - 22,4 cm2). O intervalo médio em dias entre captação e transplante foi de 15,3 (14 - 16 dias) e o número médio de cirurgias prévias ao TOF foi de 2 cirurgias (0-4 cirurgias). A pontuação na escala de IKDC objetiva no pré-operatório foi B em 12%, C em 25% e D em 63% dos pacientes; e 12% A e 88% B aos 18 meses de pós-operatório. A média da pontuação da escala IKDC subjetiva pré-operatória foi de 31,99 ± 13,4 e de 81,84 ± 9,25 em 18 meses de pós-operatório, e da escala KOOS pré-operatória foi de 46,8 ± 20,9 e de 89,58 ± 7,06 em 18 meses de pós-operatório, com melhora significativa ao longo do tempo (p < 0,01) pela análise da variância. A média da pontuação pelo índice de Merle D\'Aubigne e Postel modificado foi de 8,75 ± 2,25 no pré-operatório e de 16,75 ± 2,19 em 18 meses de pós-operatório. O resultado do teste de Friedman para amostras não-paramétricas demonstrou melhora significativa ao longo do tempo (p < 0,01). A padronização da captação, processamento e transplante de enxertos osteocondrais a fresco na articulação do joelho depende de um banco de tecidos altamente especializado e leva a excelentes resultados no tratamento de lesões osteocondrais grandes, sendo atualmente uma boa alternativa de tratamento biológico para pacientes jovens no Brasil / Treatment of chondral and osteochondral lesions of the knee in young patients is still a challenge for Orthopedic Surgeons. The techniques available nowadays in Brazil, as debridement, microfracture and autologous osteochondral transplantation are insufficient for the treatment of chondral and osteochondral lesions larger than 4 cm2. Fresh osteochondral allografts on the knee joint have been used in other countries with great success. Until the present days there are no reports of the utilization of this technique in Brazil, a fact that creates boundaries for the treatment of young active patients that need cartilage repair treatment. Eight patients with age ranging from 15 to 45 years old and osteochondral lesions larger than 4 cm2 were included in this study. Fresh grafts were obtained from organ donors and the knee joint was harvest without violation of synovium capsule and then was transported to the tissue bank for processing. Donor and receptor tissue matching occurred according to size, localization and priority on waiting list and tissue was preserved in Ham F-12 - GIBCO media with glutamax (Invitrogen, Life Technologies, United States) and antibiotics. Surgical procedure was achieved with osteochondral plugs or shell techniques, with additional fixation when needed. Patients were evaluated with IKDC objective, IKDC subjective, KOOS and modified Merle D\'Aubigne-Postel outcome scores. Eight fresh osteochondral allografts were performed from march to october, 2012. The average age was 30.1 years old (17-44) and mean graft surface area was 10.6 cm2 (4.6 - 22.4 cm2). Average time from harvest to transplantation was 15.3 days (14-16 days) and mean number of previous surgical procedures was 2 (0 - 4 procedures). Pre-operative objective IKDC score was B in 12%, C in 25% and D in 63% and was A in 12% and B in 88% in 18 months follow-up. Pre-operative IKDC subjective and KOOS score were 31.99 ± 13.4 and 46.8 ± 20.9; and in 18 months follow-up were 81.84 ± 9.25 and 89.58 ± 7.06, respectively, with a significant increase along time on variance analysis (p < 0.01). Pre-operative mean modified Merle D\'Aubigne-Postel scores were 8.75 ± 2.25 and 16.75 ± 2.19 in 18 months follow-up. Non-parametric Friedman test analysis showed a significant progression in follow-up (p < 0.01). Standards of procurement, processing and utilization of fresh osteochondral allografts in the knee joint relay on a high specialized tissue bank and promote excellent results on the treatment of large osteochondral lesions, being a good alternative of a biologic repair for young patients in Brazil
169

Importância dos diferentes estabilizadores estáticos póstero-laterais do joelho: estudo biomecânico / The role of the different static stabilizers of the posterolateral corner of the knee: a biomechanical study

Rodrigo Campos Pace Lasmar 09 May 2006 (has links)
O objetivo deste trabalho foi avaliar a importância relativa dos diferentes estabilizadores estáticos do canto póstero-lateral do joelho. Para isso foram utilizados 10 joelhos de cadáveres que foram submetidos a testes biomecânicos com a aplicação de forças para a deformação em varo e em rotação externa. Os joelhos foram testados em quatro situações diferentes e sempre na mesma seqüência: com a articulação íntegra, após a secção do ligamento colateral lateral, após a secção do ligamento colateral lateral e do complexo poplíteo-fibular (tendão do poplíteo + ligamento poplíteo-fibular) e após a secção do ligamento colateral lateral, do complexo poplíteo-fibular e da cápsula póstero-lateral. Os testes foram feitos com os joelhos em extensão, em 30 e em 60 graus de flexão. Os parâmetros estudados foram a deformação angular e a rigidez durante a aplicação do momento de flexão (varo) de 15 N.m e do momento de torção (rotação externa) de 6 N.m. A análise estatística foi realizada com o teste de comparações múltiplas de Tukey. Através da análise dos resultados obtidos com os testes biomecânicos e comparando os valores obtidos nas quatro situações estudadas entre si, foi possível interpretar a função específica de cada estrutura do canto póstero-lateral do joelho, em cada ângulo de flexão testado. Neste estudo, o ligamento colateral lateral foi importante na estabilização do joelho para o varo em extensão, em 30 e em 60 graus de flexão. O complexo poplíteo-fibular foi a estrutura mais importante na estabilização do joelho para a rotação externa, dentre as estruturas avaliadas, atuando em todos os ângulos de flexão testados. Além disto, complexo poplíteo-fibular foi importante na estabilização para o varo quando o joelho se encontrava em 30 e em 60 graus de flexão. Já a cápsula póstero-lateral foi importante na estabilização para o varo e para a rotação externa quando o joelho se encontrava em extensão, perdendo sua função à medida que o joelho foi flexionado. Em 30 graus de flexão, a cápsula póstero-lateral foi importante apenas para a estabilização em varo do joelho. / The purpose of this study was to evaluate, in cadaver knees, the relative importance of the different static stabilizers of the posterolateral corner of the knee. Tests were performed with the application of a varus and external rotation force to the knee in extension, 30 and 60 degrees of flexion, using 10 cadaver knees. The forces were applied initially to an intact knee and then repeated after a selective sectioning of the ligaments: section of the lateral collateral ligament; section of the lateral collateral ligament and the popliteofibular complex; and section of the lateral collateral ligament, the popliteofibular complex and the posterolateral capsule. The parameters studied were the angular deformity and rigidity while the knees were being submitted to a 15 newton-meter varus torque and a 6 newton-meter external tibial torque. Statistical analysis was performed using the ANOVA and Tukey tests. Our findings showed that the lateral collateral ligament was important in varus stability at 0, 30 and 60 degrees; the popliteus-fibular complex was the most important structure in external rotation stability at all angles of flexion and was also important for varus stability at 30 and 60 degrees; the posterolateral capsule was important for varus stability at 0 and 30 degrees, and for external rotation stability in extension.
170

Avaliação isocinética do joelho após reconstrução bicruzado em dois tempos / Isokinetic knee evaluation after two stages bicruciate reconstruction

Takaes, Igor Giglio, 1978- 24 August 2018 (has links)
Orientador: Sérgio Rocha Piedade / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T00:56:21Z (GMT). No. of bitstreams: 1 Takaes_IgorGiglio_D.pdf: 3495607 bytes, checksum: 997a8e42e41218f941a9801fb74230d6 (MD5) Previous issue date: 2013 / Resumo: INTRODUÇÃO: A Avaliação pós-operatória das lesões ligamentares do joelho realizada por escores clínicos, na maioria das vezes, privilegia a análise subjetiva e não fornece dados do equilíbrio muscular. A dinamometria isocinética fornece dados objetivos do déficit e equilíbrio muscular do joelho e aprimora a análise e a interpretação dos resultados pós-operatórios. OBJETIVOS: Avaliar o equilíbrio funcional do joelho pela dinamometria após reconstrução do complexo bicruzado e sua correlação com escores clínicos. MATERIAL E MÉTODOS: Foram avaliados 21 pacientes (16 homens e 05 mulheres), com idade media de 33 anos, IMC médio de 26,2 ± 3.4. Todos os pacientes foram submetidos à reconstrução cirúrgica do LCP e do LCA em dois tempos, com intervalo médio de 03 meses entre os procedimentos. Com tempo mínimo de 01 ano de pós-operatório, foi realizada a análise isocinética dos joelhos e aplicado o escore de Lysholm, Tegner e SF-36. Os testes isocinéticos foram conduzidos a 05 repetições nas velocidades de 60º/s e 180º/s e 15 repetições a 300º/s. RESULTADOS: A média do escore de Lysholm foi 82,6 ± 16,9 pontos, enquanto o escore de Tegner apresentou redução de 38,6% comparada ao nível pré-lesão. Foram obtidos os seguintes valores médios no SF- 36 nos itens: capacidade funcional (70,71); limitação por aspectos físicos (58,33); dor (73,79); aspectos gerais de saúde (80,71); vitalidade (72,0); aspectos sociais (85,12); aspectos emocionais (85,7); e saúde mental (76,76). Na avaliação isocinética, o lado operado apresentou déficit de torque extensor médio de 20 % a 60º/s, 15% a 180º/s e 14% a 300º/s, enquanto no torque flexor o déficit médio foi de 11% a 60º/s, 12% a 180º/s e 12% a 300º/s. Embora tenha sido registrado menor valor médio de torque nos joelhos operados comparado aos joelhos controle, não houve diferenças estatísticas com relação ao equilíbrio funcional do joelho (isquiotibiais/quadríceps). CONCLUSÃO: Os resultados isocinéticos da reconstrução do complexo bicruzado realizada em dois tempos evidenciaram déficit do torque extensor e flexor no lado operado. Embora, nenhum paciente tenha retornado ao nível pré-lesão, o equilíbrio funcional do joelho (flexor-extensor) pode ter contribuído para avaliação subjetiva regular nos escores clínicos / Abstract: INTRODUCTION: Postoperative evaluation of knee ligament injuries made by clinical scores, in most cases, favors the subjective analysis of the data and does not provide muscular balance. Isokinetic dynamometry provides torque deficit and knee muscle balance and thus enhances analysis and interpretation of clinical results after surgery. OBJECTIVES: To assess the functional balance of the knee after bicruciate reconstruction and its correlation with clinical scores. MATERIALS AND METHODS: We evaluated 21 patients (16 men and 05 women), mean age 33 years, mean BMI of 26.2 ± 3.4. All patients underwent surgical reconstruction of the PCL and ACL in two stages, with a mean interval of 03 months between the procedures. With a minimum of one year postoperatively, the analysis was performed isokinetic knee and applied the Lysholm score, Tegner and SF-36. The isokinetic tests were conducted to 05 repetitions at 60°/s and 180°/s and 15 repetitions at 300°/s. RESULTS: The Lysholm score was 82.6 ± 16.9 points and Tegner scores showed a deficit of 38,6% compared to pre-injury level. We obtained the following average values in items of SF-36: functional capacity (70.71); limitations due to physical aspects (58.33); pain (73.79), general health (80.71), vitality 72, social aspects (85.12), emotional aspects (85.7) and mental health (76.76). In isokinetic evaluation, the deficit of the operated quadriceps average torque was 20% at 60 º/s, 180°/s at 15% and 14% up to 300°/s, while the average flexor torque deficit was 11% at 60°/s, 12% at 180°/s and 12% at 300º /s. Although, it was registered that operated knees presented a minor mean values of torque compared to the control knees, no difference was founded to the knee functional balance (hamstrings/quadriceps). CONCLUSION: The results of isokinetic bicruciate reconstruction, performed at two stages, showed a deficit of extensor and flexor torque in the operated side. Although no patient has returned to pre-injury level, the functional balance of the knee (flexor-extensor) may have contributed to the good subjective Lysholm score / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências

Page generated in 0.2527 seconds