1

Utvärdering av kalibreringsmetoder för modväxlande kammare / An Evaluation of Calibration Methods for Reverberation Chambers

Sandahl, Anna, Wilander, Maria January 2002 (has links)
Vår uppgift var att praktiskt genomföra och utvärdera två kalibreringsmetoder för modväxlande kammare hos Saab Avionics AB i Linköping. En metod som Saab Avionics använder och en metod enligt europeisk civil flygstandard, EUROCAE ED- 14D kapitel 20.6. Uppgiften löstes genom att utföra mätningar enligt de två kalibreringsmetoderna och därefter analysera mätdata i MatLab. Vi hann med att göra Saab Avionics kalibreringsmetod i samtliga mätpunkter som krävdes för utvärderingen, men bara drygt halva kalibreringen enligt europeisk civil flygstandard. Utifrån de mätningar vi gjort kan vi dra följande slutsatser: Båda kalibreringsmetoderna säger att Saab Avionics modväxlande kammare uppfyller respektive krav när den är olastad. Båda metoderna säger också att kammaren inte uppfyller kraven när den är lastad. Däremot visar Saab Avionics kalibreringsmetod inte samma resultat i alla demätpunkter vi jämfört när kammaren var lastad och den kan därför inte anses vara tillförlitlig i sin nuvarande form. Kalibreringsmetoderna kan inte anses likvärdiga som de ser ut idag. / Our assignment was to perform and evaluate two calibration methods for reverberation chambers at Saab Avionics AB in Linköping. One method used by Saab Avionics and one according to the standard EUROCAE ED-14D chapter 20.6. The problem was solved by performing measurements according to the two methods and evaluating the data using MatLab. We managed to carry out the Saab Avionics calibration method in all of the measuring points required for the evaluation, but only half of the calibration according to EUROCAE ED-14D. From the measurements that we have performed we can draw the following conclusions: Both of the calibration methods state that the Saab Avionics reverberation chamber fulfils the requirements when it is unloaded. Both of the methods also state that the chamber does not fulfil the requirements when it is loaded. However the Saab Avionics calibration method does not give the same result in all of the measuring points that we compared when the chamber was loaded and it can therefore not be considered to be reliable in its present form. The calibration methods cannot be considered to be equal as they are today.
2

Utvärdering av kalibreringsmetoder för modväxlande kammare / An Evaluation of Calibration Methods for Reverberation Chambers

Sandahl, Anna, Wilander, Maria January 2002 (has links)
<p>Vår uppgift var att praktiskt genomföra och utvärdera två kalibreringsmetoder för modväxlande kammare hos Saab Avionics AB i Linköping. En metod som Saab Avionics använder och en metod enligt europeisk civil flygstandard, EUROCAE ED- 14D kapitel 20.6. </p><p>Uppgiften löstes genom att utföra mätningar enligt de två kalibreringsmetoderna och därefter analysera mätdata i MatLab. </p><p>Vi hann med att göra Saab Avionics kalibreringsmetod i samtliga mätpunkter som krävdes för utvärderingen, men bara drygt halva kalibreringen enligt europeisk civil flygstandard. </p><p>Utifrån de mätningar vi gjort kan vi dra följande slutsatser: Båda kalibreringsmetoderna säger att Saab Avionics modväxlande kammare uppfyller respektive krav när den är olastad. </p><p>Båda metoderna säger också att kammaren inte uppfyller kraven när den är lastad. </p><p>Däremot visar Saab Avionics kalibreringsmetod inte samma resultat i alla demätpunkter vi jämfört när kammaren var lastad och den kan därför inte anses vara tillförlitlig i sin nuvarande form. Kalibreringsmetoderna kan inte anses likvärdiga som de ser ut idag. </p> / <p>Our assignment was to perform and evaluate two calibration methods for reverberation chambers at Saab Avionics AB in Linköping. One method used by Saab Avionics and one according to the standard EUROCAE ED-14D chapter 20.6. </p><p>The problem was solved by performing measurements according to the two methods and evaluating the data using MatLab. </p><p>We managed to carry out the Saab Avionics calibration method in all of the measuring points required for the evaluation, but only half of the calibration according to EUROCAE ED-14D. </p><p>From the measurements that we have performed we can draw the following conclusions: Both of the calibration methods state that the Saab Avionics reverberation chamber fulfils the requirements when it is unloaded. </p><p>Both of the methods also state that the chamber does not fulfil the requirements when it is loaded. </p><p>However the Saab Avionics calibration method does not give the same result in all of the measuring points that we compared when the chamber was loaded and it can therefore not be considered to be reliable in its present form. The calibration methods cannot be considered to be equal as they are today.</p>
3

Harry Potter och Hemligheterna bakom adaptionen : En semiotisk analys om hur Harry Potter som karaktär översatts från bok till film i ”Hemligheternas Kammare”

Qvarnström, Julia January 2016 (has links)
Syftet med denna uppsats är att undersöka hur Harry Potter som karaktär framställs i boken Harry Potter och Hemligheternas Kammare i jämförelse med filmadaptionen med samma namn. Genom en semiotisk analys på två nivåer granskas karaktären för att se på vilka sätt karaktären Harry Potters personliga egenskaper och tankar har översatts och ändrats i förflyttningen från bok till film. I slutdiskussionen visas att Harry Potter har förändrats något i adaptionen, men hans personlighet framställs i slutändan mycket som densamma. Att karaktären innehar samma personlighet och påvisar samma egenskaper är viktigt för att adaptionen ska fungera och gör att själva berättelsen i adaptionen inte måste vara fullt trogen till originalet för att ge samma bild.
4

Användande av myocardial performance index vid bedömning av vänster och höger kammares systoliska och diastoliska funktion / Assessment of systolic and diastolic function in both ventricles with myocardial performance index

Lundqvist, Michelle January 2023 (has links)
Vid en ekokardiografisk undersökning läggs fokus främst på klaffunktion, hjärtrumsstorlek och vänstersidans systoliska funktion. Vänstersidans diastoliska funktion har dock börjat få större betydelse, men upplevs ofta vara svårbedömd. Höger kammare har en komplex anatomi med ett trabekulerat myokardie och är otillgängligt placerad i bröstkorgen, vilket gör den svårare att bedöma än vänster kammare. 1995 publicerades ett index för bedömning av hjärtats kombinerade systoliska och diastoliska funktion, myocardial performance index (MPI). Syftet med studien var att undersöka om MPI kan vara en användbar och kompletterande metod vid bedömning av systolisk och diastolisk funktion i höger respektive vänster kammare. I den aktuella studien ingick 33 personer i åldrarna 21–80. MPI beräknades med pulsad vävnadsdoppler under en hjärtcykel. MPI jämfördes mot traditionella ekokardiografiska mätmetoder som speglar systolisk och diastolisk funktion för vänster respektive höger kammare. Normalfördelnings-, korrelations- och överrensstämmelseanalyser utfördes. För vänstersidig kammarfunktion sågs en signifikant korrelation mellan MPI och MAPSE. Ingen eller dålig överensstämmelse sågs mellan MPI och samtliga traditionella mätmetoder för systolisk funktion. För högersidig kammarfunktion sågs en starkt signifikant korrelation mellan MPI och FAC samt TAPSE. Mindre god överensstämmelse sågs mellan högersidans MPI och FAC samt TAPSE. För MPI och E/e’ sågs ingen signifikant korrelation hos vare sig vänster eller höger kammare och en sämre överensstämmelse än om klassificeringen hade gjorts rent slumpmässigt. Användbarheten av MPI för bedömning av vänster kammarfunktion anses, baserat på aktuell studie, vara låg. MPI kan vara användbart vid bedömning av höger kammares systoliska funktion, men inte avseende diastolisk funktion.
5

Vem vill bygga 100 000 000 lägenheter? : En studie om den politiska debatten i riksdagens första kammare kring SOU 1965:32 och den svenska bostadspolitiken.

Nilsson, Linnea January 2023 (has links)
No description available.
6

Paddle stirrer to a reverberation chamber

Mastrorilli, Andrea, Holmgren, Josefin January 2019 (has links)
Halmstad University is currently equipped with an Echo-free chamber to perform EMC testing, but no reverberation chamber. The construction of a paddle stirrer to be utilized in Halmstad University would drastically reduce the time required to perform EMC testing, since reverberation chambers are more efficient than Echo-free chambers for these kind of tests. The goal of this project was to design and develop a paddle stirrer structure and a control system able to rotate the stirrer to specific repeatable absolute angles with an accuracy of a tenth of a degree,holding a mass up to 70kg and rotating a mass up to 20 kg distributed on a 1x1m surface. To achieve this goal the system has been designed using a metal base structure, bearings to hold the lower shaft in its axes reducing its friction, a stepper motor connected to the gears to increase its holding torque, a magnetic rotary encoder and a control system with a double feedback from interrupts and from the encoder to improve the accuracy and reliability of the system. The resultis a completely working prototype, which fulfils all the requirements except for the speed. The target speed has not been achieved due to the insufficient holding torque of the available stepper motor. / Halmstad Högskola är för närvarande utrustad med en Ekofri kammare för att utföra EMCtestning, men ingen modväxlande kammare. Konstruktionen av en paddle-omrörare för användning i Halmstad Högskola skulle drastiskt minska tiden som krävs för att utföra EMC-testning, eftersom modväxlande kammaren är effektivare än en ekofri kammare för dessa typer av tester.Målet med detta projekt var att designa och utveckla en paddle-omrörare, både strukturen samt ett styrsystem som kan rotera den till specifika repeterbara absoluta vinklar med en noggrannhet av en tiondel av en grad, hantera en massa upp till 70 kg och rotera en massa upp till 20 kg fördelad på en 1x1m yta. För att uppnå detta mål har systemet konstruerats med en basstruktur gjord av metall, lager har placerats i axeln för att reducera friktion, en stegmotor är anslutentill kugghjul för att öka vridmomentet, en magnetisk roterande sensor och ett styrsystem med en dubbel återkoppling från interrupts och från sensorn för att förbättra systemets noggrannhet och tillförlitlighet. Resultatet är en helt fungerande prototyp som uppfyller alla krav, förutom hastigheten. Målhastigheten har inte uppnåtts på grund av otillräckligt vridmoment hos stegmotorn.
7

Whole-body SAR measurements of 5G mmW base stations in a reverberation chamber / Helkroppsbaserade SAR-mätningar i en modväxlande kammare av 5G-basstationer i millimetervågsområdet

Eilers Bischoff, Jens January 2022 (has links)
This study presents a method for measurement of whole-body average specific absorption rate (WBSAR) of a millimeter wave (mmWave) antenna in a reverberation chamber. The method takes advantage of multiple radiated power measurements to estimate the power absorbed in a phantom placed in front of the antenna. The first set of measurements is a total radiated power estimation of the antenna. The second set measures the radiated power from the combined antenna and phantom system. By taking the difference between the two measurements, the power absorbed in the phantom and hence WBSAR, which is defined as the total power absorbed in a body divided by the whole-body mass, can be estimated. This method builds on previous reverberation chamber techniques and improves them by isolating only the power absorbed from direct illumination corresponding to a realistic exposure environment of mmWave antennas with high directivity. Verification has been performed by comparing measurements of a horn antenna with a simulation. The difference between measurements and simulation has been found to be less than 1 dB, while the maximum measurement uncertainty was estimated to be 1.1 dB. With the developed method, WBSAR measurements of an Ericsson 5G mmWave base station has been conducted. In 2020 the International Commission on Non-Ionizing Radiation Protection (ICNIRP) published new guidelines for radio frequency electromagnetic fields containing limitations for WBSAR up to 300 GHz. Since these guidelines are new there is currently no standardized measurement method to assess WBSAR in the mmWave frequency ranges. Therefore, the proposed method could be of interest for standardization institutions. / I denna studie presenteras en metod för att i en modväxlande kammare mäta helkroppsbaserad specifik absorptionshastighet (whole-body average specific absorption rate, WBSAR) för en antenn i millimetervågsområdet. Metoden använder mätningar av utstrålad effekt i två situationer, utan och med en helkroppsmodell (fantom). Först mäts den utstrålade effekten från antennen utan fantom, sedan mäts den när fantomen är placerad framför antennen. Differensen mellan de två mätningarna ger den absorberade effekten i fantomen, vilken kan användas för att bestämma WBSAR genom att dela med massan. Metoden bygger på tidigare tekniker för modväxlande kammare och utvecklar dem genom att isolera effekten absorberad från direkt exponering. På så sätt ger metoden realistiska resultat för starkt riktade millimetervågsantenner. Verifikation har utförts genom att jämföra mätningar av en hornantenn med simuleringar vid 28 GHz. Skillnaden mellan de mätta och simulerade värdena var mindre än 1 dB och med en uppskattad maximal mätosäkerhet på 1.1 dB. Med den utvecklade metoden mättes WBSAR för en Ericsson 5G basstation vid frekvensen 28 GHz. År 2020 publicerade ICNIRP nya riktlinjer för exponering för radiofrekventa elektromagnetiska fält som inkluderar begränsningar av WBSAR vid frekvenser upp till 300 GHz. Eftersom dessa riktlinjer är nya finns nuvarande ingen standardiserad metod för att mäta WBSAR i millimetervågsområdet. Metoden kan därför vara av intresse för standardiseringsorganisationer
8

UTFÖRANDE AV EJEKTIONFRAKTIONSMÄTNING MED HJÄLP AV SIMPSON METOD AV EN STUDENT OCH EN ERFAREN BIOMEDICINSK ANALYTIKER / PERFORMANCE OF EJECTION FRACTION MEASURMENT WITH SIMPSON METHOD BY A STUDENT AND AN EXPERIENCED BIOMEDICIAL SCIENTIST.

Flamarz, Diana January 2020 (has links)
Echocardiography examination is an important and familiar method for heart`s examination. Echocardiography is used to assess the function of the heart during to check the heart disease. In an echocardiography examination, the heart´s flow rates, contractility (pumping capacity), wall thickness, and inner diameter can be examined. All these examinations are done with the help of evolution of the ultrasonic waves that the ultrasonic transducer sends out and receives. The transducer consists of piezoelectric crystals that can both transmit and receive ultrasonic waves with frequencies exceeding 20 kHz. The purpose of the study is to compare the measurement of the left ventricular ejection fraction (LVEF) between an experienced biomedical scientist (BMA) and a student. In addition to see how the image quality affects the result. The measurement was performed by using the Simpson method. The result was analyzed by using with a static method. The results were analyzed by using a paired t-test to see if there is any significant difference between the performance of a BMA and a student. The measurement was performed on apical 4-chamber and apical 2-chamber image. The study included 30 patients, both heart -healthy and cardiac patients of the genders. The result showed that there is a significant difference in the performance of LVEF- measurements between BMA and student, with lower values measured by the student. / Ekokardiografiundersökning är en viktig och vanlig metod vid undersökning av hjärtat. Ekokardiografi används för att bedöma hjärtats funktion vid utredning av hjärtsjukdomar. Vid en ekokardiografiundersökning kan hjärtats flödeshastigheter, kontraktilitet (pumpförmåga), väggtjocklek, och innerdiameter undersökas. Alla dessa undersökningar görs med hjälp av tolkning av ultraljudsvågorna som ultraljudsgivaren skickar ut och tar emot. Givaren består av piezoelektriska kristaller som kan både sända och tar emot ultraljudsvågor med frekvens på över 20 kHz. Syftet med denna studie är att jämföra mätningen av den vänstra ventrikulära ejektionsfraktion (LVEF) mellan en erfaren biomedicinsk analytiker (BMA) och en student samt att se hur bildkvalitén påverkar resultatet. Mätningen utfördes med Simpsons- metoden. Resultatet analyserades med hjälp av en statistisk metod. Resultatet analyserades med hjälp av parat t-test för att se om det finns någon signifikant skillnad mellan utförandet av en BMA och en student. Mätningen utfördes på apikala 4-kammarbilder och apikala 2-kammarblider. Studien inkluderade 30 patienter, både hjärtfriska och hjärtsjuka patienter av både könen. Resultatet visade att det finns en signifikant skillnad i utförande av LVEF- mätningar mellan BMA och student, med lägre uppmätta värden av studenten.
9

Simpsons biplan metod jämfört med Philips Heart Model vid bestämning av vänsterkammares ejektionsfraktion / Simpson’s biplane method compared to the Philips Heart Model when determining the left ventricular ejection fraction

Kassem, Sara January 2021 (has links)
Introduktion: Vänsterkammarens ejektionsfraktion (VKEF) är ett central mått på systolisk funktion i vänster kammare och är en av de mest betydelsefulla parametrar vid ekokardiografiska undersökningar. Idag är Simpson biplan metoden den mest använda metoden för bestämning av ejektionsfraktionen. Vid ekokardiografiska undersökningar sänder givaren med piezoelektriska kristaller ut ultraljudsvågor med en frekvens över 20 000 Hz. Ljudvågorna som skickas ut i kroppen reflekteras och sedan återvänder de till givaren för att skapa en bild. Denna studie jämför den tvådimensionella (2D) ultraljudsmetoden Simpsons biplan med Philips Heart Model som är en automatiserad tredimensionella (3D) funktion för bedömning av VKEF.  Material och metod: I studien inkluderades 31 hjärtfriska försökspersoner mellan åldrarna 21-64. Det samlades in bilder på apikala 4- och 2 kammarbilder från alla försökspersoner där Simpsons biplan metoden användes för att beräkna ejektionsfraktion. Apikala 4-kammarbilder samlades in för att beräkna ejektionsfraktionen med Philips Heart Model 3D funktion.  Resultat: Resultatet från denna studie visade att det inte föreligger någon signifikant skillnad mellan Simpsons biplan metoden och Philips Heart Model metoden för bestämning av ejektionsfraktion. Båda metoderna visade likvärdiga mätresultat.  Diskussion: Philips Heart Model metoden är en relativ ny funktion som använder sig av artificiell intelligens för att analysera 3D bilder. Philips Heart Model metoden är en säker funktion att använda då de flesta studier bevisar likvärdiga och säkra mätresultat i jämförelse med andra metoder.  Konklusion: Enligt denna studie ger Philips Heart Model funktionen likvärdiga mätresultat av vänsterkammarens ejektionsfraktion i jämförelse med Simpsons biplan. / Introduction: Simpson’s biplane method is the most used method for determining the left ventricular ejection fraction (LVEF) in echocardiographic examinations. Ejection fraction is a central measurement of the heart's global systolic function. The probe with piezoelectric crystals emits ultrasound waves with a frequency above 20,000 Hz. The sound waves that are sent out into the body are reflected and then return to the probe to create an image. This study compares the two-dimensional (2D) ultrasound Simpson's biplane method with the Philips Heart Model method, which is an automated three-dimensional (3D) function for assessment of LVEF.                                                                                                                          Material and method: 31 subjects with no recorded heart pathologies between the ages of 21-64 were included in the study. Apical 4- and 2-chamber images were collected from the test subjects, where the Simpson's biplane method was applied to calculate the ejection fraction. 2D apical 4-chamber images were collected to convert to 3D and used to calculate the ejection fraction with the Philips Heart Model.    Results: The results of this study showed that there is no significant difference between the Simpson’s biplane method and the Philips Heart Model method for determining ejection fraction.    Discussion: The Philips Heart Model method is a relatively new feature that uses artificial intelligence to analyze 3D images. The Philips Heart Model method is a reliable feature to use as most studies have proven similar and reliable measurements when comparing it with other methods for determining LVEF.    Conclusion: According to this study, the Philips Heart Model feature provides equivalent measurements in comparison with the manual method Simpson's biplane.
10

Development of a Novel Method for Automotive On-board Transmitter EMC Immunity Testing / Utveckling av en Immunitetsmetod för Elektromagnetisk Kompatibilitetstestning vid Simulering av Strålningskälla i Fordon

Holm, Ludvig January 2023 (has links)
As the automotive industry advances through technology integration, components are designed to operate at increasingly higher frequencies. Consequently, there will be an increasing demand for automotive electromagnetic compatibility (EMC) testing. Testing and certification institutes, such as RISE Research Institutes of Sweden AB, thus face an urgent need to develop innovative solutions that can effectively address this growing demand. This master thesis work concerns one EMC test method in particular - the On-board Transmitter (OBT). This is a test which mainly serves to test the immunity of vehicles to electromagnetic disturbances originating from hand-held devices. The conventional test is performed in an anechoic chamber and the methodology requires a substantial amount of time. The intent with this work is thus to evaluate the potential of a novel OBT method where the concept of a reverberating chamber is applied inside the vehicle compartment. Initially, the conventional method was examined from two mock-ups of idealized cases, and it was observed that the electromagnetic field in the near-field region of the transmitter is highly erratic. It was also concluded that the test setup is particularly sensitive to the polarization of the transmitter. With these findings in mind, the accuracy of the conventional method was deemed questionable. Evaluation of the proposed Reverberating On-board Transmitter (ROBT) method proved that the electromagnetic environment inside the vehicle did not resemble a perfect reverberation chamber. Which was expected as the absorbing material such as seating and upholstery likely prevents a field distribution similar to that in a reverberation chamber. Still, the intent of the project was to find a test method superior to the conventional method and it can be stated that the ROBT method is an adequate option due to its capacity to expose the electronics to isotropic radiation. This was found from two measures which this thesis introduces: expected isotropicity eiso, a relative measure of the electric field components and DDoF, a quantification of the spatial distribution inside a reverberation chamber. / EMC VERifiering av Autonoma fordon i modväxlad kammare (EMCVERA)