1

FMV, Ledningscontainer AMF LEDNCO20PA - Utvärdering av klimatstyrning och komfort / FMV, Commande and Control Unit AMF LEDNCO20PA - Evaluation of climate

Johnsson, Anders, Sandén, Johan January 2004 (has links)
No description available.
2

Simulering av klimatstyrning i Härnevi kyrka : påverkan på fuktupplagringen i en medeltida stenvägg / Climate control simulation in Härnevi church : moisture storage analysis of a medieval stone wall

Thor, Henric, Jesper, Håkansson January 2018 (has links)
This thesis examines how the moisture content of a stone wall from the 15th century varies with different types of climate control. The simulations in this report is based on measured data from sensors placed inside and outside Härnevi Church north of Enköping. The measured data are processed to simulate different climate control strategies in the church porch. The simulated climate control strategies are temperature control and air-dehumidification, the systems are controlled against either a mold risk curve or a fixed maximum value for the relative humidity. The simulations are performed with the program WUFI Pro 6.1; which performs onedimensional hygrothermal calculations of building component crosssections and is an alternative to the traditional Glaser-Method.Many climate simulations have been performed, though only four are fully accounted for in this dissertation. Simulations that have not resulted in surface conditions below the mold risk curve LIM I has not been included in the investigation process. Simulation results are based on climate controls against "fixed relative humidity max 71%" and "mold risk curve LIM I-10 percentage points". The results show that the desorption process of the wall is similar to all four simulations but provides different absorption processes, control against the mould risk curve allows the wall a faster water content build up. The simulations show that control against the mould risk curve results in a greater moisture storage in the wall during the winter months; compared to control the climate against a constant relative humidity. During summertime there is no significant difference in moisture storage between the various climate control simulations. The operating time to control against the mould risk curve for one year is roughly 1000 hours less than control against constant relative humidity. When considering the results in this report together with Härnevi church's current heating system, this dissertation recommends a climate control based on temperature control against a mould risk curve. The results also show the importance of investigating the difference between the mold ratio in the air and on the surface of the wall to perform a proper and safe climate control.
3

Vidareutveckling av krav för klimatstyrning och konstruktion i SEP – Splitterskyddad enhetsplattform, Försvarets Materielverk / Further development of requirements for climate control and construction in SEP – Modular Armoured Tactical System, Defence Materiel Administration

de Verdier, Magnus January 2005 (has links)
No description available.
4

En brukbarhetsanalys av avancerad fastighetsautomation under förvaltningsskedet / An analysis of the serviceability of advanced Building Automation during the management stage

Esselin, Frida, Selimovic, Seherzada January 2015 (has links)
Avancerad fastighetsautomation intog marknaden under 2000-talets första år. Visionen var att skapa smarta byggnader där fastighetsövervakning, klimatstyrning och belysning sammankopplades mot en central huvuddator för att eliminera manuell styrning. Syftet med examensarbetet är att undersöka funktionalitet och reell brukbarhet hos ett av de första installationsobjekten, PostNords huvudkontor. Rapporten presenterar fastighetens övergripande funktioner samt analyserar hur systemstyrningen kan optimeras för bättre lönsamhet respektive komfort. Exemplifieringen påvisar generella risker och potential med avancerade styrsystem i förvaltningsskedet. Arbetet har begränsat sig till fastighetens kontorsytor som stället högst krav på inomhusklimat och användarvänlighet. För att nå uppsatt mål har litteraturstudier, intervjuer, egna observationer samt en genomgång av fastighetsdokumentation genomförts. Resultatet visar att den höga teknikgraden gjort förvaltarna beroende av inhyrd spetskompetens. Det avancerade språket har försvårat kommunikationen mellan parterna vilket begränsat möjligheten att optimera systemet. Förbättring av inomhusklimat och energiprestanda kan först ske när man förstår en helhet. Förvaltarna borde tillsätta en samlad kartläggning av hela systemet istället för att experimentera med ytterligare ny teknik. / Advanced building automation reached the market in the early 2000s. The vision was to create smart buildings where property surveillance, climate control and lightning where to be linked through a main computer to eliminate manual control. The purpose with this thesis is to investigate the functionality and real serviceability of one of the first objects of installation, the PostNord headquarters. This thesis presents the overall features of the real estate and also analyses how the control system can be optimized for higher profitability and comfort. The exemplification shows general risks and potential with advanced control systems in real estate management. This work is limited to the real estates office spaces that demand the highest standards of indoor environment and convenience. To reach set goal, studies of literature, interviews, observations and reviews of property documentation have been executed. The result shows that a high level of technical complexity has made the property managers dependent on hiring expert consultants. The advanced use of language has made the communication between the parts difficult, which has limited the opportunity to optimize the system. Improvement of indoor climate and energy efficiency can only be reached when the entire case is grasped. The real estate managers should start a complete mapping of the system instead of experimenting with additional technology.
5

Klimatstyrning – en branschanalys : Struktur och problemområden för energieffektivisering i fastighetssektorn / Indoor climate control – an industry analysis

Vallejo, Victor January 2011 (has links)
Energieffektivisering är en trend som för närvarande genomsyrar hela samhällsdebatten. Politiska reformer för energieffektivisering som genomförs på såväl lokal som global nivå påverkar även hur aktörer inom näringslivet fattar olika beslut. En sektor där påverkan varit speciellt stor är bygg- och fastighetssektorn, som bedöms stå för närmare 40 procent av samhällets energiförbrukning. Påtryckningar från myndigheter, hyresgäster och andra intressenter samt ett stigande energipris uppmanar många fastighetsägare att se över sina fastigheters energiåtgång vid drift och förvaltning. Samtidigt medför den snabba teknikutvecklingen inom byggnadsautomation för värme, ventilation och kyla att nyproducerade fastigheter idag har mycket stor effektiviseringspotential. Dessa förändringar ställer dock allt högre krav på fastighetsägarnas kompetens vid upphandling av klimattekniska installationer till fastigheterna. Syftet med undersökningen som presenteras i detta arbete har varit att utreda hur branschen för klimatstyrning av fastigheter är uppbyggd och kartlägga upplevda problem i dess struktur. Det empiriska materialet till undersökningen är hämtat från intervjuer med fastighetsägande kunder till företaget Styrvärden Q AB, ett företag i styr- och reglerbranschen. I rapportens slutsatser konstateras att branschen för klimatstyrning byggs upp huvudsakligen av fyra strategiska grupper som tillsammans formar en mycket statisk branschstruktur med strikt avgränsade ansvarsområden. Bland de identifierade branschproblemen återfinns en intressekonflikt mellan aktörer inom byggprojektledning respektive förvaltning, där byggaktörerna vill maximera projektvinsten medan förvaltningen främst bryr sig om driftekonomin. Ett annat problem som identifierats i branschstrukturen är bristfälliga kopplingar mellan projektering och installation, som ofta genomförs av två skilda aktörer. Ytterligare ett branschproblem är att dagens struktur försummar eftermarknadens betydelse, det vill säga marknaden för service och tjänster kopplade till klimatstyrningen. / Energy efficiency is a hot topic in the modern discourse concerning environmental and economic sustainability. The political measures taken on local and global levels affect society in general, and the industrial world in particular. One business sector that has been especially influenced by these trends is the building and construction sector, said to be responsible for about 40 percent of society’s energy consumption. Due to increasingly strict requirements from authorities, tenants and other stakeholders; property owners have begun to adjust their views and policies regarding energy management. Also, thanks to the rapid technological advances within building automation and HVAC-technologies (Heating, Ventilation and Air Conditioning); newly produced buildings obtain ever greater potential for energy conservation. At the same time, these changes set higher requirements for how property owners procure HVAC-systems for their buildings. The purpose of this dissertation has been to investigate the configuration of the so called indoor climate control industry and to identify perceived structural problems within it. The source material for the paper was acquired through a series of interviews in a market research study conducted on behalf of Styrvärden Q AB – a company in the building automation industry. The study concludes that the industry of indoor climate control consists of four strategic groups of players. Together they make up an industry characterized by great rigidity and inflexible zones of responsibility. One prominent industry problem is a conflict between construction project managers and property managers; project managers try to maximize the profit margin for separate projects while property managers mainly care about optimizing their buildings’ net operating income. Another industry problem consists of the weak link between system design and installation, as the two activities are generally carried out by separate contractors. Finally, one problem is found to be that today’s industry structure omits the significance of an aftermarket for maintenance and services related to the indoor climate control systems.
6

Shapers, Brokers and Doers : The Dynamic Roles of Non-State Actors in Global Climate Change Governance / Formare, Mäklare och Görare : Icke-Statliga Aktörers Dynamiska Roller i den Globala Klimatstyrningen

Nasiritousi, Naghmeh January 2016 (has links)
Non-state actors, such as international environmental organisations, business associations and indigenous peoples organisations, increasingly take on governance functions that can influence the delivery of global public goods. This thesis examines the roles of these actors in the field of global climate change governance. Specifically, the thesis examines why and how non-state actors are involved in global climate change governance, the governance activities that they may perform and are perceived to perform, and their views on climate change solutions. The thesis also discusses the implications of their roles for how authority is shared between states and non-state actors in global climate change governance. The research questions are addressed by triangulating several empirical methods. The results show that the roles of non-state actors are continuously evolving and depend on the changing nature of relations between state and non-state actors as well as efforts by non-state actors to expand their policy space by justifying and seeking recognition for their participation. Moreover, the findings point to the importance of differentiating between groups of non-state actors, as they represent diverse interests and have different comparative advantages across governance activities. Which non-state actors participate and to what extent therefore has implications for the effects of their involvement in global climate change governance. On the basis of a systematic assessment of a set of non-state actors, this thesis concludes that the key role-categories of non-state actors in global climate change governance are broadly: shapers of information and ideas, brokers of knowledge, norms and initiatives, and doers of implementing policies and influencing behaviours. Different non-state actors carry out activities within these role-categories to different extents. In addition to the empirical mapping of the roles of non-state actors in global climate change governance, this thesis contributes to two strands in the literature: one theoretical focusing on the authority and legitimacy of non-state actors in global environmental governance, and the other methodological, offering a toolbox that combines survey data with qualitative methods. / Icke-statliga aktörer, exempelvis internationella miljöorganisationer, näringslivsorganisationer och ursprungsbefolkningsorganisationer, fyller alltmer framträdande funktioner i den globala klimatstyrningen. Dessa organisationer kan därmed påverka utformningen av globala kollektiva nyttigheter. Denna avhandling undersöker dessa aktörers roller inom den globala klimatstyrningen. Avhandlingen utforskar varför och på vilket sätt icke-statliga aktörer deltar i den globala klimatstyrningen, uppfattningar om vilka styraktiviteter de utför, och ifall de bidrar till en mer pluralistisk syn på klimatproblematikens lösningar. I avhandlingen diskuteras vilka konsekvenser de icke-statliga aktörernas roller har för hur auktoritet delas mellan stater och icke-statliga aktörer i den globala klimatpolitiken. Forskningsfrågorna behandlas genom att triangulera flera empiriska metoder. Resultaten från dessa undersökningar visar att de icke-statliga aktörernas roller utvecklas kontinuerligt och att dynamiken dels beror på den skiftande relationen mellan statliga och icke-statliga aktörer, dels på de icke-statliga aktörernas egna ansträngningar att öka sitt politiska handlingsutrymme och få erkännande för sitt deltagande. Dessutom pekar resultaten på vikten av att skilja mellan olika grupper av icke-statliga aktörer, eftersom de representerar skilda intressen och har komparativa fördelar i olika styraktiviteter. En konsekvens av detta är att det spelar roll vilka grupper av icke-statliga aktörer som ges tillträde till den internationella klimatdiplomatin. Baserat på en systematisk  bedömning av vad några av de icke-statliga aktörerna anses göra, dras slutsatsen att de viktigaste rollkategorierna som icke-statliga aktörer har är: formare av information och idéer, mäklare av kunskap, normer och initiativ, och görare genom att bidra till implementering och påverka beteenden, men att olika icke-statliga aktörer utför dessa roller i olika utsträckning. Utöver den empiriska kartläggningen av icke-statliga aktörers roller i den globala klimatstyrningen, bidrar avhandlingen dels till den teoretiska litteraturen kring icke-statliga aktörers auktoritet och legitimitet inom den globala miljöstyrningen, dels metodologiskt genom att utveckla analysverktyg som kombinerar enkätdata med kvalitativa metoder.
7

Inneklimatet på Skoklosters slott : en studie av ett klimatexperiments första år

Justin Moll, Adam January 2014 (has links)
Inneklimatet på Skoklosters slott är på vissa håll problematiskt. Mögelangrepp förekommer i somliga rum, främst sådana som är belägna i norrläge och därmed lite kallare än övriga rum. För att finna en lösning på mögelproblemen inleddes våren 2013 ett treårigt experiment vars syfte var att utröna om mögelproblemen skulle kunna undvikas med aktiv klimatstyrning, vilket inte funnits innan experimentet. Tre olika klimatstyrningsanläggningar installerades i tre rum på slottet, samtidigt som mätningar gjordes i referensrum utan aktiva åtgärder. De tre klimatstyrningsanläggningarna som valdes ut var avfuktning, skyddsvärme och fuktstyrd ventilation. I mars 2014 avslutades första året av experimentet.Ur mögelrisksynpunkt har inneklimatet i nästan alla rum, både försöks- och referensrum, varit relativt godartat. Sämst inneklimat uppmättes i skyddsvärmerummet, vilket förmodligen beror på rummets egna förutsättningar snarare än skyddsvärmen. Bäst inneklimat hade rummet med den fuktstyrda ventilationen, som gav ett oväntat bra resultat och dessutom var den av klimatstyrningsanläggningarna som var mest i bruk. Det är emellertid för tidigt att med säkerhet säga vilken av anläggningarna som vore bäst för slottet.Vid en diskussion om de antikvariska konsekvenserna av en genomgripande installation av en klimatstyrninganläggning blev slutsatsen att det för slottets kulturhistoriska värde vore gynnsamt att göra en genomgripande installation ifall detta skulle innebära att slottets samlingar kunde behållas på plats. Rummens olika fysiska och kulturhistoriska förutsättningar kräver dock att individuella utformningar undersöks, vilket innebär att det kan bli aktuellt med en kombination av olika klimatstyrningsanläggningar. / The indoor climate of Skokloster palace is not without problems. There have been mould growth in some rooms, mainly those who are facing north and therefore are colder than other rooms. To find a solution for the problems with mould growth, a three-year long experiment was initiated in the spring of 2013. Its purpose was to examine if mould growth could be avoided with active climate control, which had not been tested previously in the palace. Three different climate control systems were installed in three rooms, and meanwhile the indoor climate of three rooms without active climate control was logged. The three climate control systems chosen were dehumidification, conservation heating, and humidity controlled ventilation. The first year of the experiment ended in March 2014.The climate in nearly all rooms was acceptable in a mould risk perspective. The room with conservation heating had the least suitable climate, which probably is explained by the condition of the room itself rather than the effects of the conservation heating. The room with humidity controlled ventilation hade the best climate during the year, and the ventilation system had the most uptime of the climate control systems. It is however too early to tell which system might be the best after only one year.When discussing what consequences a thorough installation of a climate control system might have on the cultural heritage values of Skokloster palace, the conclusion was that it would be favourable to install active climate control – if that allowed the collections of Skokloster to remain in the building. Due to the different physical and cultural conditions of the palace’s rooms, it will be necessary to find tailored solutions for climate control systems. In order to do that, a combination of different climate control systems might be worth looking into. / Spara och bevara - Energimyndighetens forskningsprogram för energieffektivisering i kulturhistoriskt värdefulla byggnader