• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 369
  • 168
  • Tagged with
  • 537
  • 535
  • 535
  • 520
  • 518
  • 516
  • 516
  • 43
  • 27
  • 26
  • 26
  • 24
  • 17
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Titerbestämning av anti-A och anti-B i trombocytenheter för transfusion över ABO gränsen : utvärdering av rutinanalys och utveckling av en screeningmetod / Anti-A and anti-B titers in platelets for transfusion across ABO : evaluation of a routine analyze and implementation of a screening method

Frohm, Hanna January 2018 (has links)
Trombocyter är suspenderade i plasma som innehåller antikroppar mot de blodgruppsantigen som saknas på erytrocyterna. För att minimera risken för en hemolytisk reaktion bestäms titern av anti-A och anti-B. Gelkortsteknik används för att detektera antikropp-antigensreaktioner och baseras på agglutinationer i en gel. Syftet med studien var att undersöka titern av anti-A och anti-B i trombocytenheter, samt att utvärdera en rutinanalys och utveckla en screeningmetod. I studien analyserades enheter av blodgrupp O och A. De kontrollerades mot anti-A och/eller anti-B både för IgG och IgM antikroppar. En screeningmetod utvecklades för att kunna screena O-enheterna och en gräns på 1:100 respektive 1:250 undersöktes. Resultatet kunde påvisa en stor skillnad i titer mellan O-och A-enheter. Titern skiljer sig signifikant beroende på om titern bestäms i plasma eller från den färdiga (utspädda) enheten. En screeningmetod på 1:100 påvisade att 86 % av enheterna hade bedömts som hög titer och en screeningmetod på 1:250 visade att andelen sjönk till 31 %. Geltekniken är en känslig metod och är beroende av kompetent personal vid avläsning. En del studier visar liknande resultat men andelen enheter med hög titer varierar och likaså metoder och titergräns. Detta påvisar svårigheterna i att bestämma en kritisk titer och att förutse risker hos patienten. Andra faktorer tros också kunna påverka riskerna. Införande av en screeningmetod på 1:250 kan öka antalet enheter som kan transfunderas över ABO-barriären. / Platelets are suspended in plasma containing antibodies to the blood group antigen missing on the erythrocytes. To minimize the risk of hemolytic reaction, the titrers of anti-A and anti-B are determined. The gel test is used to detect antibody-and antigen responses and is based on agglutinations in gel. The purpose was to investigate the titers of anti-A and/or anti-B in platelets. A routine analysis was evaluated and a screening method was implemented. In the study, units of blood group O and A were analyzed. They were checked against anti-A and anti-B for both IgG and IgM antibodies. A screening method was developed to screen the O-units and a limit of 1:100 and 1:250 was used. The results showed great difference in titers between O and A units. The titers differ significantly depending on whether the titers are determined in plasma or from the finished (diluted) unit. A screening method at 1:100 showed that 86 % of the units was rated as high titer while a screening method of 1:250 showed that this was reduced to 31 %. Gel technology is a sensitive method and is dependent on competent staff when reading the agglutinations. Some studies show similar results, but the proportion of high titer units, methods and critical titers varies. It proves the difficulty in determining a critical titer and predicting risks for the patient. Other factors are also believed to influence the risks. Implementation of a 1:250 screening method is believed to increase the number of units that can be transfused over the ABO barrier.
412

Utvärdering av en ny metod för utredning av stabil kranskärlssjukdom baserad på akustisk fonokardiografi / Evaluation of a new method for the investigation of stable coronary artery disease using acoustic phonocardiography

Kurashova, Elena January 2018 (has links)
Kranskärlssjukdom (CAD) är en av de vanligast förekommande kardiovaskulära sjukdomarna och en av de dominerande dödsorsakerna hos äldre människor världen över. För att bekräfta diagnos och bedöma sjukdomens svårighetsgrad används idag flera diagnostiska strategier. Ökade hälsokostnader och lång kö för undersökningar väcker oro hos både patienter, läkare och myndigheter. Behovet av en enkel, säker och kostnadseffektiv metod som kan hjälpa till i utredning av CAD är stor. Det danska företaget Acarix utarbetade en ny apparat, CADScor®-system, som använder en icke-invasiv och strålningsfri metod för att utesluta stabil CAD baserad på akustisk fonokardiografi. Apparaten spelar in koronarblåsljud, vilket uppstår vid stenos i kranskärl, och beräknar patientens risk för CAD. Syftet med den här studien var att utvärdera metoden, testa CADScor® och beräkna apparatens sensitivitet, specificiteten samt positivt och negativt prediktivt värde (PPV och NPV). Tjugo patienter med misstänkt stabil CAD undersöktes med CADScor®-system och deras CAD-resultat jämfördes med resultatet efter myokardscintigrafi. Beräkningar visade att apparatens sensitivitet är 80 %, specificitet 60 %, PPV 40 % och NPV 90 %. Resultatet innebär att sannolikheten är 90 % för att en patient som fick CAD-score ≤ 20 är frisk. Det är tillräckligt högt för att använda CADScor® i klinisk praxis för patienter med låg risk för CAD. / Coronary artery disease (CAD) is one of the most common cardiovascular diseases and one of the dominant causes of death in older people worldwide. In order to confirm diagnosis and assess the severity of the disease, several diagnostic strategies are being used today. Increased health costs and long queues for investigations raise concerns among patients, medical doctors and authorities. A simple, safe and cost-effective method that can assist in the investigation of CAD is of major importance. The Danish company Acarix developed a new device, CADScor® system, which uses a non-invasive and radiation-free method to exclude stable CAD based on acoustic phonocardiography. The device records intracoronary murmurs, resulting from coronary stenosis, and calculates the patient's risk of CAD. The purpose of this study was to evaluate the method, test CADScor® and calculate the device's sensitivity, specificity and positive and negative predictive value (PPV and NPV). Twenty patients with suspected stable CAD were examined with CADScor® systems, and their CAD results were compared to the result after myocardial perfusion scan. Calculations showed that the device's sensitivity is 80 %, specificity 60 %, PPV 40 % and NPV 90 %. The result means that the probability is 90 % that a patient who has a CAD score ≤ 20 is healthy. It is high enough to use CADScor® in clinical practice for patients with low risk for CAD.
413

Jämförelse av två enzyme-linked immunosorbent assays : mätning av diabetesspecifika autoantikroppar i en adult population / Comparison of two enzyme-linked immunosorbent assays : measurement of diabetes-specific autoantibodies in an adult population

Gashi Krasniqi, Lauresha January 2018 (has links)
Typ- 1 diabetes (T1D) är en autoimmun sjukdom med insulinbrist orsakad av nedbrytning av insulinproducerande betaceller i pankreas. Fyra olika antikroppar har identifierats som är riktade mot betacellsspecifika antigen; insulinautoantikroppar (IAA), glutamic acid decarboxylase antibodies (GADA), islet antigen2-antikroppar (IA-2A) och antikroppar riktade mot zinktransportören 8 (ZnT8A). I denna studie gjordes en jämförelse av metoderna 2screen islet cell autoantibody ELISA-kit (RSR, Cardiff, UK) och 3screen islet cell autoantibody ELISA- kit (RSR, Cardiff, UK), vars brunnar är coatade med GAD65/IA-2 antigen respektive GAD65/IA-2/ZnT8 antigen, för att undersöka ifall dessa båda kit ger jämförbar sensitivitet och specificitet i en adult population av nydebuterade patienter med T1D och friska vuxna blodgivare. RSR 2screen erhöll 1 % högre specificitet (98 %) jämfört med RSR 3screen (97 %) vid samma sensitivitet (92 %) och rekommenderas i första hand för screening av autoantikroppar i en population av vuxna patienter med ökad risk för T1D och friska vuxna blodgivare. / Type- 1 diabetes (T1D) is an autoimmune disease with insulin deficiency caused by degradation of insulin- producing betacells in pancreas. Four different autoantibodies that target beta- cell specific antigenes have been identified: insulinautoantibodies (IAA), glutamic acid decarboxylase antibodies (GADA), islet antigen2-antibodies (IA-2A) and antibodies against zinktransporter 8 (ZnT8A). In this study, a comparison between 2screen islet cell autoantibody ELISA-kit (RSR, Cardiff, UK) coated with GAD65/IA-2 and 3screen islet cell autoantibody ELISA- kit (RSR, Cardiff, UK) coated with GAD65/IA-2/ZnT8, was performed to investigate whether results from these two kits provide comparable sensitivity and specificity in an adult population of new onset patients with T1D and healthy adults. RSR 2screen obtained 1 % higher specificity (98 %) in comparison to RSR 3screen (97 %) on the same sensitivity (92 %) and is recommended primarily for screening of autoantibodies in a population of adult patients at increased risk for T1D and healthy adults blood donors.
414

The neurobiology underlying personality traits and conflict behavior : Examining the similarities in brain regions between agreeableness, aggression and dominating conflict style

Kralj, Andrea January 2018 (has links)
Conflicts are part of our everyday life and the field of psychology describes how specific personality traits relate to specific conflict styles. However, the question remaining is why these relations exist? Recently, personality neuroscience has begun pinning down the neurobiology of personality traits, providing a deeper understanding of the human behavior. The present thesis utilizes the Five Factor Model (FFM; Costa & McCrae, 1990) of personality to investigate the neurobiology underlying the inverse relation between the specific personality trait of Agreeableness and dominating conflict style (a conflict management style characterized by aggressiveness, authoritarianism and/or need for dominance). Agreeableness overlaps both empathy and aggression which can work as each other’s opposites in explaining conflict behaviors. The goal of the thesis was to investigate whether the inverse relation between Agreeableness and dominating conflict style can be explained by brain regions. Brain regions such as the medial prefrontal cortex and regions involving anterior cingulate appear to be the most prominent neurobiology describing the relation. Serotonin is the neural substance involved in most cortical and subcortical brain structures and it also regulates the suppression of aggression, making it an important substance both within Agreeableness and the preference for dominating conflict style. The thesis will sum up with a discussion including some limitations within the research and further aspects such the consequences of the findings will be discussed.
415

En jämförelse mellan transthorakal och transesofageal ekokardiografi : Metod att föredra vid undersökning av Staphylococcus aureus-endokardit / A comparison between transthoracic and transesophageal echocardiography : Method to prefer when examining Staphylococcus aureus-endocarditis

Erlandsson, Gabrielle, Johansson, Karin January 2018 (has links)
Syftet med studien var att jämföra hur väl transthorakal (TTE) och transesofageal ekokardiografi (TEE) kompletterar varandra vid diagnosticering av Staphylococcus Aureus (S. aureus) -endokardit (SAE). S. aureus är en av de ledande bakterierna inom vårdrelaterade infektioner. SAE blir vanligare, något forskare relaterar till att fler invasiva ingrepp görs. TTE är förstahandsalternativet för att besvara alternativt dementera frågeställningen och följs ofta av en TEE som bidrar till förbättrad bildkvalité och möjlighet att visualisera mindre strukturer. På Skaraborgs sjukhus i Skövde (SkaS) anses TEE-undersökningarna många gånger genomförs i onödan då få endokarditer hittas. Studien var jämförande med en kvantitativ ansats. Materialet har samlats in på kliniskt fysiologiskt laboratorium i Skövde. Det resulterade i elva deltagare. Båda könen inkluderades, patienter under 18 år exkluderades. Resultatet visade att fyra endokarditer diagnostiserades. Streptococcus Sanguinus var den bakterie som orsakade flest endokarditer medan S. aureus inte orsakade någon endokardit. Fem av elva patienter hade någon form av riskfaktor för endokardit. Fem av elva patienter blododlades positivt för S. aureus. Hygienen vid undersökningstillfällena, framförallt TEE är viktig då 80 % av vårdpersonalen kan vara bärare av S. aureus. TTE- och TEE-undersökningen kompletterar varandra. Kombinationen av undersökningarna gör resultatet tillförlitligt. TEE är därför av värde vid endokarditfrågeställning. / The purpose was to compare how transthoracic (TTE) and transesophageal echocardiography (TEE) complement each other in the diagnosis of Staphylococcus Aureus (S. aureus)-Endocarditis (SAE). S. aureus is one of the leading bacteria in health-related infections. SAE becomes more common, which researchers associate with more invasive interventions. TTE is a first step to confirm or rule out endocarditis and often followed by TEE-examination. At Skaraborg Hospital in Skövde (SkaS), the TEE-survey is considered unnecessary many times when not finding enough endocarditis. The study was a comparative study with quantitative approach, where the material was collected at clinical physiological laboratory at SkaS, Skövde, which resulted in eleven participants. Both sexes were included, patients below 18 years were excluded. Results showed that four endocarditis was diagnosed. Streptococcus Sanguinus was the bacterium that caused most endocarditis while S. aureus did not cause endocarditis. Five of eleven patients had some form of risk factor for endocarditis. Five of eleven patients were positive for S. aureus. Hygiene at the examinations, especially TEE is important because 80 % of healthcare professionals could be carriers of S. aureus. The TTE and TEE survey complement each other. Carrying out the surveys together is what makes the diagnosis safe.
416

HbA1c – En jämförelse mellan två nya analysmetoder gentemot en befintlig

Marrouki, Gabi January 2018 (has links)
Glykerat hemoglobin, HbA1c, är en indikation på genomsnittligt glukosvärde. HbA1c används vid diagnostisering av diabetes men också uppföljning av diagnostiserade diabetiker. Uppföljningen visar hur väl diabetiker förhåller sig till kost men också medicinering. Informationen av patientens HbA1c värde spelar en stor roll i vidare behandlingar. Analysmetoden HbA1c är inte helt standardiserad vilket har medfört att flera analysmetoder utvecklats för HbA1c. Syftet med denna studie var att undersöka om en enzymatisk, Direct enzymatic HbA1c eller immunologisk analysmetod, Hemoglobin A1c kan lösa problemet med hemoglobin-variationer vid analys av HbA1c som idag analyseras med HPLC som rutin på klinisk kemi-laboratorium i Västerås. Genomförandet gjordes på två instrument, TOSOH G7 och AU 680. TOSOH:s värden (HPLC) användes vid jämförelse av de två analysmetoderna på AU680. Förberedelse och behandling, såsom hemolysering, skedde innan proven sattes i instrumentet AU680. Resultatet (n=134) visade att analysmetoden Hemoglobin A1c förhöll sig väl till HPLC analysmetod (R 2=0,98) jämfört med vad analysmetoden Direct enzymatic HbA1c gjorde (R2=0,86). Likartade resultat kunde observeras för Hemoglobin A1c (R2=0,98) och Direct enzymatic Hba1c (R2=0,95) då bara patientprov med hemoglobin-varianter analyserades (n=10). Mann-Whitney’s U-test vid analys av hemoglobin varianter med Hemoglobin A1c visade en tendens till signifikant skillnad gentemot HPLC analysen (p=0,051; n=34). Fel reagens erhölls från reagenstillverkaren gällande Direct enzymatic, Detta kan förklara det erhållna resultatet och kräver fler analyser med korrekta reagens. Hemoglobin A1c bör även undersökas vidare med mer omfattande provmaterial för möjlig standardisering i rutin hos KKTM i Västerås. / Glycated hemoglobin, HbA1c, is an indication of average long-term glucose. HbA1c is used as a diagnostic method for diabetes but also as a follow-up for diagnosed diabetics. Follow-ups shows how well a diabetic relates to diet but also medication. The information of the patient's HbA1c value plays an important factor in further treatments. The analysis method for HbA1c is not standardized, which has resulted in several analysis methods developed for HbA1c. The purposes of this study were to investigate whether an enzymatic, Direct enzymatic HbA1c or immunological assay method, Hemoglobin A1c, can solve the problem of hemoglobin variations in the analysis of HbA1c, which is currently analyzed by HPLC as a routine at the clinical chemistry laboratory in Västerås The implementation was performed on two instruments, TOSOH G7 and AU 680. The values from TOSOH (HPLC) were used for comparison of the two analysis methods applied on the AU680. Preparation and treatment, such as hemolysis, occurred before putting the samples into the AU680 instrument. The result showed that the Hemoglobin A1c assay method was well-matched with HPLC assay (R2 = 0.98) in comparison to that of the Direct enzymatic HbA1c assay method (R2 = 0.86). Similar results could be observed for Hemoglobin A1c (R2 = 0.98) and Direct Enzyme HbA1c (R2 = 0.95) when only samples from patients with hemoglobin variants were analyzed (n=10). Solely analysis of hemoglobin variants with Hemoglobin A1c showed a boundary case for a significant difference compared to HPLC analysis (P = 0.051; n=134). Incorrect reagents were obtained from the reagent manufacturer in the case of Direct enzymatic. This can explain the results obtained. Hemoglobin A1c should also be investigated with more extensive test materials for possible standardization in the routine of KKTM in Västerås.
417

Jämförelse av två diffusionskapacitetsmetoder : en pilotstudie / Comparison of two diffusing capacity methods : -a pilot study

Johansson, Elin January 2017 (has links)
Pulmonary function testing is an important part when it comes to evaluating patients with or at risk for lung diseases. Measurement of the diffusing capacity with carbon monoxide (DLCO) of the lung is a very important parameter and reflects how well the gas exchange work. Traditionally the DLCO have been measured by the single breath (SB) method which requires a forcefully inhalation and a 10 second breath-hold. Not all patients are able to perform the method due to illness or related problems therefore it would be favourable if the ward could change to an easier method called intrabreath (IB). The IB method is not depending on a breath-holding manoeuvre, which should make it easier to perform. Eleven volunteers participated in the study. They all performed both DLCO techniques, starting with the SB followed by IB. The DLCO, when determined with the IB technique, had an excellent correlation to the SB technique. However, the IB systematically showed a lower value for DLCO, and can therefore not use the same references as SB. Before the ward can change from the SB- to the IB- method there are needs for further studies. New studies should include more volunteers so more trustworthy reference values can be made, they should also include sick patients as a check-up for the new reference values. For the moment the ward have to stay with the SB method.
418

Jämförande studie av vänster kammarvolymer och vänster kammarmassa hos hjärtsviktspatienter med bevarad ejektionsfraktion och friska kontroller / A comparative study of left ventricular volumes and left ventricular mass in heart failure patients with preserved ejection fraction and healthy controls

Svensson, Lisa January 2017 (has links)
Hjärtsvikt är en hjärt-kärlsjukdom som drabbar allt fler människor i världen. Varje år söker ungefär en miljon patienter i U. S. A vård för symptom för hjärtsvikt. Kronisk hjärtsvikt delas in efter ejektionsfraktion, bevarad och reducerad. Vid bevarad ejektionsfraktion är det ofta en sämre fyllnad av vänster kammare. Magnet resonans tomografi (MR) är en undersökningsmetod som använder kroppens egna vätejoner för att skapa en bild med hjälp av ett starkt magnetfält och anses vara ”gold standard” för att mäta hjärtats volymer och massa. Syftet med den här studien var att jämföra vänster kammarvolymer, massa och funktion hos hjärtsviktspatienter med bevarad ejektionsfraktion och friska kontroller. Sju patienters och åtta friska kontrollers hjärtan undersöktes med magnetkamera på Skånes Universitetssjukhus i Lund. Bilderna analyserades genom manuell utlinjering av vänster kammare. Ingen statistiskt signifikant skillnad mellan grupperna kunde visas. I motsats med tidigare studier visade den nuvarande studien ingen skillnad i vänster kammarvolymer, massa och funktion. Dock kan den nuvarande studien anses vara begränsad på grund av det låga antalet patienter och kontroller. / Heart failure is a cardiovascular disease which affects more and more people in the World. Every year, approximately one million patients in the United States seek care for symptoms of heart failure. Chronic heart failure is categorized by ejection fraction, preserved or educed ejection fraction. In preserved ejection fraction it is common with a reduced filling of the left ventricle. Magnet resonance imaging (MR) is a test method which uses the hydrogen ions in the body to create an image using a magnetic field and is considered a “gold standard” to measure the heart volumes and mass. The aims of this study were to compare left ventricular volumes, mass and function in heart failure patients with preserved ejection fraction and healthy controls. The hearts of seven patients and eight healthy controls were examined in a magnetic camera at Skåne’s University Hospital in Lund. The images were analyzed by manual delineation of the left ventricle. No statistical significant difference could be demonstrated between the groups. In contrast with earlier studies this study did not show any difference in left ventricular volumes, mass and function. However, the current study is limited due to the low number of patients and controls.
419

Correlations between anthropometricmeasurements, fasting-insulin andrespiratory quotent in obese children

Gustafsson, Felicia January 2015 (has links)
The number of obese children has increased with almost 100 % in a few decades. Deceases like insulin-resistance and type-2 diabetes often comes with overweight and worldwide research to prevent and cure these complications is constantly approaching. This study provides with greater knowledge of what correlations there are between anthropometric measurements, insulin resistance and respiratory quotient.For this study, data from 83 children and teenagers was included. The medical records from their first visit to the pediatric science unit at Uppsala University Hospital was used. To measure basal metabolic rate (BMR), indirect respiratory calorimetrics was used to measure the respiratory ratio at rest and fasting (RQ-BMR), and blood samples were collected to analyze fs-(fasting) insulin. The anthropometric measurements that were taken were waist, waist-height-ratio (WtHR), waist-hip ratio (WHR), waist-hip-height ratio (WHtR), waist circumference (AC), waist circumference-height ratio (ACHR), sagittal abdominal diameter (SAD) and Sagittal abdominal diameter-height ratio (SADHR).Correlations between fs-insulin and WHtR, WCHR, SAD and SADHR was found for the whole group of participators in this study. The strongest correlation was to WHtR for boys and SAD for girls. The RQ-BMR correlated the best with SADHR and ACHR. No correlations between RQ-BMR were found specifically for boys or girls.
420

Visualisering av amyloider och patogenes i skadad näthinna

Persson, Daniel January 2017 (has links)
Ansamling av amyloid beta (Aβ) i de extracellulära miljöerna är associerad till många svåra sjukdomar som Alzheimers och ålders-relaterad makuladegeneration (AMD). Amyloider karaktäriseras av att de är olösliga, toxiska mot neuron och orsakar därför svår skada. AMD är den ledande orsaken till blindhet och irreversibelt förlorande av skarp syn då Aβ manifesterar i makula. I AMD orsakar Aβ inflammatorisk aktivitet där det retinala pigmentepitelet bryts ned och ljuskänsliga fotoreceptorer dör genom apoptos. Idag lever ca 150 miljoner människor med AMD där mänga har svårt att utföra vardagliga uppgifter till följd av förlust av skarp syn. Idag är Kongo röd en av de vanligaste metoderna för att visualisera amyloider in vitro. Den patogenes som orsakas av amyloider kan analyseras med immunofluorescens och immunohistokemi. Syftet med studien var att undersöka förekomst av amyloider i samband med celldöd i näthinna från gris, undersöka den patogenes som amyloider orsakar med immunofluorescens och immunohistokemi, samt undersöka om det finns korrelation mellan amyloider och celldöd. Resultatet visade att amyloider var förekommande i näthinnan och hade orsakat celldöd och ansamling av aggresomer. Amyloider och den patologi som orsakats kunde visualiseras i det yttre lagret av näthinnan. / Deposition of amyloid beta (Aβ) in the extracellular environment are associated to some severe diseases, like Alzheimer’s disease and age-related macular degeneration (AMD). Amyloids are characterized by insolubility, toxicity towards neuron and are there-for damaging to tissues. AMD is the primary cause of blindness and irreversible loss of central vision through manifestation of Aβ in the macula. In AMD, Aβ drives an inflammatory action that degenerates the retinal pigment epithelium and cause atrophy of photoreceptors. Today ~150 million people live with AMD where many find difficulties performing everyday tasks due to loss of sharp vision. Congo red is a gold standard for visualizing amyloids in vitro and the pathogenesis caused by amyloids can be analyzed by immunofluorescence and immunohistochemistry. The purpose of this study was to show the presence of amyloids relating to cell death in pig retina, show the pathogenesis caused by amyloids by using immunofluorescence and immunohistochemistry, and investigate whether there is correlation between amyloids and cell death. The result showed that amyloids were present in the retina and caused cell death and gathering of aggresomes. Amyloids and the caused pathology could be visualized in the outer layer of the retina.

Page generated in 0.0932 seconds