• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Belysningsnivåer vid receptionsdiskar / Illumination levels at reception desks

Berg, Therese, Siljeskog, Adam January 2014 (has links)
Detta examensarbete undersöker hur belysningen vid receptionsdiskar faktiskt serut och hur personalen som arbetar där upplever den. Syftet med examensarbetetär att identifiera om det finns anledning att förändra de riktlinjer och rekommendationersom ställs på belysning på och omkring receptionsdiskar. På hotellen idag är oftast miljöerna dämpade och varierande då hotellens syfte äratt skapa en upplevelse för gästerna. Det har väckt ett intresse hos oss att undersökareceptionsdisken som är en viktig plats på hotellen. Vi har jämfört ”Ljus ochRums” rekommendationer (SIS, 2011) med faktiskt uppmätta ljusnivåer i fyra receptionsdiskaroch personalens upplevelse av hur det påverkar hur de kan utförasina dagliga arbetsuppgifter. De metoder vi har använt är ljusmätning, jämnhetsberäkning, visuell analys ochenkätundersökning. Ljusmätningarna utfördes på fyra olika hotell i Göteborg.Frågeformuläret vände sig till personalen på hotellen och handlade om deras upplevelseav ljuset på och omkring receptionsdisken. För att få en uppfattning ochövergripande förståelse utfördes en visuell analys på hotellen. Majoritet av personalen anser att belysningen var tillräcklig för att utföra sina arbetsuppgifter.Det är tydligt att ljuset uppfattas olika på de fyra receptionsdiskarnaberoende på hur hotellet är utformat och designat. / The purpose of this study is to identify if there is reason to change the requirementsand recommendations for illumination in reception desks areas. This studyexamines how lighting in reception desks areas actually is and how the staff perceivesthe lighting. Hotels today usually have subdued environments that vary according to the typeof experience intended for their guests. Our interest has been to explore the receptiondesks area as an important and separate element within the hotel. We havecompared “Ljus och Rum” recommendations (Swedish Standards Institute [SIS],2011) with actual measured light levels for four reception desks areas and examinedhow the staff perceives how the lighting affects their performance of dailytasks. The methods we have used are light measurement, evenness calculations, visualanalysis and surveys. Lighting measurements were performed at four differenthotels in Gothenburg. The questionnaire was directed to the hotel staff in order toascertain their perception of the lighting in and around the reception’s desks area.In order to get an impression of and gain an overall understanding for the lighting,a visual analysis was done at each hotel. The majority of the staff considers the lighting sufficient to perform their duties.It is clear that the lighting is perceived differently in each of the four hotels, dependingon how each hotel is formed and how the lighting is designed.
2

Ljusets påverkan på ljudnivån i ett klassrum i grundskolan

Sethberg, Frida, Wik, Nina January 2016 (has links)
A good work environment in school is crucial in order to effectively teach and learn. Two factors that have a strong impact on the environment in a classroom is the lighting and the sound level. Research has shown that both light and sound have an impact on the health, and while a lot of research has been done on the work environment and the impact by different factors, very few studies have focused on how light and sound affect each other. The purpose of this study is to shed light on how the lighting can affect the sound level in a classroom. The results of this study could be used as a reference as to how the lighting should be set up in order to creative the most effective work environment in a classroom. In order to study if the sound level changes depending on the lighting, a quantitative field experiment has been performed. The study took place in a classroom with 6th graders in primary school. During 12 weekdays over a period of 3 weeks, the decibel values were logged to find out whether the sound level changed. During the first week, the original lighting was used. During the second week, the light was dimmed, and during the third and final week, the light was unevenly spread out. The results show that the sound level is indeed affected by the lighting in the classroom. The unevenly spread out lighting setup with a focus on vertical surfaces resulted in the lowest sound level. One conclusion that can be drawn is that more focus on the ambient light affects the students positively. The most important conclusion is that a lighting setup with different luminaires and a variety of the light levels and spread depending of the time of the day and season, is affecting the sound level and work environment in the classroom in a positive way. / En bra arbetsmiljö i skolan är en viktig förutsättning för att kunna förmedla kunskap. Två parametrar som har stor betydelse i ett klassrum är belysningen och ljudnivån. Forskning visar att både ljus och ljud påverkar hälsan men trots mängden forskning gällande arbetsmiljön och dess påverkande parametrar finns det fåtal forskningar som studerar hur ljus och ljud påverkar varandra. Syftet med studien och denna rapport är att öka kunskapen om hur ljussättning kan påverka ljudnivån i ett klassrum i grundskolan. Studien kan användas som underlag för hur klassrum bör belysas för att påverka arbetsmiljön i ett klassrum. För att undersöka om ljudnivå förändras vid förändrad ljusnivå respektive förändrad ljusfördelning har ett kvantitativt fältexperiment utförts. Studien genomfördes i ett hemklassrum för årskurs 6 och under tolv veckodagar under tre veckors tid loggades decibelvärden. Under vecka 1 var klassrummets ursprungliga belysning kvar, under vecka 2 sänktes ljusnivån och sista veckan skapades en ojämn ljusfördelning. Resultaten visar att ljudnivån kan ändras i ett klassrum med hjälp av belysningen, och studien resulterade i att den ojämna belysningen med fokus på vertikala ytor och omfältsljuset gav den lägsta ljudnivån. Slutsatser som kan dras av resultaten är bland annat att mer fokus på omgivningsljuset påverkar elevernas välmående i en positiv riktning. Den viktigaste slutsatsen är ändå att en belysningslösning med tillgång till olika typer av armaturer och möjlighet att kunna variera både ljusnivå och ljusfördelning beroende på lektion och tid på dygnet och årstid bidrar till en bättre arbetsmiljö i klassrummet.
3

Studie om individers kontrastkänslighet och preferenser för horisontell och vertikal belysningsstyrka / A Study about individual contrast sensitivity and preferences for horizontal and vertical lighting intensity

Folkesson, Phliip, Kjellström, Andreas January 2009 (has links)
<p>The purpose of this study is to survey and evaluate if the individual contrast sensitivity and preferences for horizontal and vertical lighting level correspond to the values that standard SS-EN 12464-1 recommends for the workplace- and surrounding light levels.</p><p>This study examines if lighting should be adapted after the individuals’ need or if a general value can be found that will cover every individuals’ need for a workplace and surrounding light level. This study also examines if parameters like sex, age and/or glasses/lenses have an effect on the amount of lighting that the test subjects need. Lastly we compared the values concerning the relationship between workplace- and surrounding light levels with standard SS-EN 12464-1’s recommendations.</p><p>The study is carried out with an experimental design that surveys 220 test subjects who were chosen by a selection of convenience. The test subjects did perform a test where they estimated their individual need for lighting in office environments regarding lighting for workplace and its surroundings. Every test subject carried out the test where they repeated the same attempt three times, to establish if the individual lighting need oscillated or if it was constant, whereupon the results were analyzed, compiled and compared to standard SS-EN 12464-1.</p><p>The results show that the minim- and maxim value for the test subjects is between 70 – 4300 lux. The result varies with different parameters such as sex, age and glasses/lenses. We could also state that the relationship between workplace- and surrounding light levels is slightly higher than what standard SS-EN 12464-1 recommends, which should be taken into consideration when planning future lighting constructions.</p><p>Based on the results in this study, our conclusion is that standard SS-EN 12464-1 does not cover the needs on the comfort levels that the test subjects indicated. The values that the test subjects indicated differ from the values that standard SS-EN 12464-1 recommends.</p><p>Since there is a huge spread of the experienced need for lighting between individuals and age groups, we draw the conclusion that general values of measure can’t be applied as a standard on neither workplace- nor surrounding light levels. To fulfill the needs that users have, the lighting construction should be adapted for the individual and give a lighting flood that will fill the individual needs for workplace lighting.</p>
4

Studie om individers kontrastkänslighet och preferenser för horisontell och vertikal belysningsstyrka / A Study about individual contrast sensitivity and preferences for horizontal and vertical lighting intensity

Folkesson, Phliip, Kjellström, Andreas January 2009 (has links)
The purpose of this study is to survey and evaluate if the individual contrast sensitivity and preferences for horizontal and vertical lighting level correspond to the values that standard SS-EN 12464-1 recommends for the workplace- and surrounding light levels. This study examines if lighting should be adapted after the individuals’ need or if a general value can be found that will cover every individuals’ need for a workplace and surrounding light level. This study also examines if parameters like sex, age and/or glasses/lenses have an effect on the amount of lighting that the test subjects need. Lastly we compared the values concerning the relationship between workplace- and surrounding light levels with standard SS-EN 12464-1’s recommendations. The study is carried out with an experimental design that surveys 220 test subjects who were chosen by a selection of convenience. The test subjects did perform a test where they estimated their individual need for lighting in office environments regarding lighting for workplace and its surroundings. Every test subject carried out the test where they repeated the same attempt three times, to establish if the individual lighting need oscillated or if it was constant, whereupon the results were analyzed, compiled and compared to standard SS-EN 12464-1. The results show that the minim- and maxim value for the test subjects is between 70 – 4300 lux. The result varies with different parameters such as sex, age and glasses/lenses. We could also state that the relationship between workplace- and surrounding light levels is slightly higher than what standard SS-EN 12464-1 recommends, which should be taken into consideration when planning future lighting constructions. Based on the results in this study, our conclusion is that standard SS-EN 12464-1 does not cover the needs on the comfort levels that the test subjects indicated. The values that the test subjects indicated differ from the values that standard SS-EN 12464-1 recommends. Since there is a huge spread of the experienced need for lighting between individuals and age groups, we draw the conclusion that general values of measure can’t be applied as a standard on neither workplace- nor surrounding light levels. To fulfill the needs that users have, the lighting construction should be adapted for the individual and give a lighting flood that will fill the individual needs for workplace lighting.
5

LJUSFÄRGMÄTTNADENS PÅVERKAN PÅ ENERGIEFFEKTIVITET OCH TRYGGHETSKÄNSLA / INCREASED LIGHT COLOR SATURATIONS EFFECT ON ENERGY EFFICACY AND FEELING OF SAFTEY

Jidberg, Hugo, Schön, Elias January 2023 (has links)
The high electricity prices are a talked about issue in today's society where many peoplefind themselves in a critical situation as a result of them. In a more long-termperspective, Sweden faces a goal of a comprehensive transformation of the energysystem. Lighting is a contributing factor to the energy system and energy use. Light inthe form of lighting is important for the visibility of objects and the surroundings, whichis a contributing factor to safety in society.The stock market price for electricity prices in December 2022 shows a sharp risethroughout Sweden and the forecast for today's electricity prices continues to rise(Konsumenternas, 2022). Energy consumption has a direct correlation to electricitycosts and dimmed LED light sources lead to lower energy consumption (Jägerbrand,2011). An important aspect in how the sense of safety, security and architecture isemphasized is the color rendering and light level of the lighting. A study carried out byMinchen et al (2020) proves that a light source with an increased color saturation and alower used illuminance can give rise to an equivalent visibility of a board as a lightsource with lower color saturation and higher illuminance.The aim is to identify and describe previous areas of knowledge about the colorsaturation and color reproduction of light sources. Tentative theory must be tested tosee if future outcomes can be predicted with the aim of lowering the light level andenergy consumption through increased color saturation and its impact on visibility andperceived safety.In order to achieve the aim and answer the study's questions, a literature search has beencarried out, in both primary and secondary sources, with keywords and search stringsin the scientific database Web of science together with the help of the snowball methodand snowball technique. In addition, available light source data from light sourcesuppliers has been analyzed to investigate the correlation between energy consumptionand color saturation. In order to further investigate the subject and answer the questions,an experiment was carried out with two different lighting scenarios of a modeled tunnel.During the experiment, participants contributed quantitative and qualitative data byanswering questionnaires for these scenarios.The study shows that light color saturation has an impact on the energy efficiency oflight sources and that different interpretations of how light color saturation and lightlevel affect the perceived visibility. The study indicates that a lower light level can beapplied without negatively affecting safety if other factors for the environment are takeninto account, where one of the contributing factors may be light color saturation. / De höga elpriserna är en omtalad fråga i dagens samhälle där många befinner sig i enkritisk situation till följd av dem. I ett mer långsiktigt perspektiv står Sverige inför ettmål till en omfattande omställning av energisystemet. Belysning är en bidragande faktortill energisystemet och energianvändningen. Ljus i form av belysning är viktig försynbarheten till objekt och omgivningen som är en bidragande faktor till tryggheten isamhället.Börspriset för elpriser i december 2022 visar en kraftig stigning i hela Sverige ochprognosen för dagens elpriser fortsätter att stiga (Konsumenternas, 2022).Energiförbrukningen har en direkt korrelation till elkostnaderna och dimrade LEDljuskällorleder till lägre energiförbrukning (Jägerbrand, 2011). En viktig aspekt i hurkänslan av trygghet, säkerhet och arkitektur framhävs är belysningens färgåtergivningoch ljusnivå. En studie utförd av Minchen et al (2020) påvisar till att en ljuskälla meden ökad färgmättnad och en lägre använd belysningsstyrka kan ge upphov till enlikvärdig synbarhet av en tavla som en ljuskälla med lägre färgmättnad och högrebelysningsstyrka.Syftet är att identifiera och beskriva tidigare kunskapsområden om ljuskällorsfärgmättnad och färgåtergivning. Tentativ teori ska prövas till om framtida utfall kanförutsägas i syfte att sänka ljusnivån och energiförbrukningen genom en ökadfärgmättnad och dess påverkan på synbarheten och den upplevda tryggheten.För att uppnå syftet och besvara studiens frågeställningar har en litteratursökninggenomförts, i både primära och sekundära källor, med nyckelord och söksträngarvetenskapliga databasen Web of science tillsammans med hjälp av snöbollsmetodenoch snöbollsteknik. Därtill har tillgänglig ljuskälledata från ljuskälleleverantöreranalyserats för att undersöka korrelation mellan energiförbrukning och färgmättnad.För att vidare undersöka ämnet och besvara frågeställningarna genomfördes ettexperiment med två olika belysnings-scenarion av en modellerad tunnel. Underexperimentet bidrog deltagarna med kvantitativa och kvalitativa data genom att besvaraenkäter till dessa scenarion.Studien visar att ljusfärgmättnaden har en påverkan på ljuskällors energieffektivitet ochatt olika tolkningar hur ljusfärgmättnad och ljusnivå påverkar den upplevdasynbarheten. Studien indikerar att en lägre ljusnivå kan appliceras utan att påverkatryggheten negativt om andra faktorer för omgivningen tas i beaktning, där en av dombidragande faktorerna kan vara ljusfärgmättnad.

Page generated in 0.0268 seconds