• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 1
  • Tagged with
  • 48
  • 48
  • 42
  • 34
  • 25
  • 25
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação do músculo masseter através da eletromiografia de superfície após aplicação do laser de baixa potência em indivíduos submetidos à exodontia de terceiros molares inferiores retidos / Evaluation by surface electromyography of the masseter muscle after low-intensity laser therapy in patients undergoing extraction of retained inferior third molars

Sevilha, Fabio Moschetto 19 May 2014 (has links)
A cirurgia de terceiro molar é um dos procedimentos mais realizados na área de cirurgia e traumatologia bucomaxilofaciais, e buscando um aumento na velocidade da recuperação pós-cirúrgica, muitos recursos fisioterápicos são empregados, entre eles a laserterapia e o acompanhamento da evolução pode ser baseado em evidência clínica. Neste trabalho, foi proposto acompanhar a evolução pós-cirúrgica através da utilização do eletromiografia de superfície em dois grupos distintos: pacientes sem fisioterapia com laser no pós-operatório e pacientes tratados no pós-cirúrgico com laserterapia. Realizamos quatro tomadas, no pré-operatório, normalizando, e três no pósoperatório, 7, 14, 21 dias, em amostra de 60 pacientes. Observamos, que no sétimo dia no grupo onde houve a aplicação do laser de baixa intensidade 23,3% dos pacientes ja haviam recuperado sua atividade muscular do préoperatório contra apenas 3,3% do grupo controle, ja no décimo quarto dia 73,3% contra 6,7% do grupo controle e no vigésimo primeiro dia 80% contra 10% do grupo controle. Constatamos através da eletromiografia de superfície que a utilização do laser de baixa intensidade acelera significativamente a recuperação muscular pós-trauma cirúrgico / The surgery for extraction of the retained inferior third molar is one of the most commonly performed procedures in the field of maxillofacial surgery and traumatology. With the aim of accelerating the post-surgical recovery, many physiotherapy resources are employed, including laser therapy and its evolution was based on clinical evidence. In this study, we proposed to monitor the post-surgical evolution by using surface electromyography in two distinct groups of patients, treated or not with laser therapy postoperatively. In a sample of 60 patients, we held four evaluations: preoperatively, normalizing, and three times after surgery, at 7, 14, and 21 days postoperatively. On the seventh day, 23.3% of the patients in the group receiving low intensity laser had already regained their muscle activity as they presented preoperatively, versus only 3.3% of the control group. In the fourteenth day, this happened with 73.3% of treated patients versus 6.7% in the control group, and in the twenty-first day, 80% versus 10% in the control group. It was verified, by surface electromyography evaluation, that the use of low intensity laser significantly accelerates muscle recovery after surgical trauma
32

Efeito da Doença de Parkinson na eficiência dos ciclos mastigatórios / Effect of Parkinson\'s disease on the efficiency of masticatory cycles

Silva, Nayara Soares da 02 February 2018 (has links)
Doença de Parkinson é classificada como uma doença crônica degenerativa e progressiva, prevalecendo em indivíduos de 50 a 70 anos de idade, sendo mais comum no gênero masculino. Apresenta como principais sinais e sintomas o tremor ao repouso, bradicinesia, rigidez muscular e instabilidade postural, comprometendo a cadeia musculoesquelética. Esta pesquisa avaliou a eficiência dos ciclos mastigatórios por meio do envoltório linear do sinal eletromiográfico do músculo masseter, temporal e esternocleidomastoideo em indivíduos com doença de Parkinson. Foram selecionados 24 participantes na faixa etária entre 50 e 70 anos que foram distribuídos em dois grupos: com Doença de Parkinson (média ± DP 66,16 ± 3,37 anos, n=12) e sem Doença de Parkinson (média ± DP 65,83 ± 3,01 anos, n=12). O eletromiógrafo MyoSystem-I P84 foi utilizado para avaliar a eficiência dos ciclos mastigatórios na mastigação habitual e não habitual. Os dados foram tabulados e submetidos à análise estatística (teste t de student, p <= 0.05). Os resultados demonstraram que o grupo com a Doença de Parkinson apresentou aumento da atividade eletromiográfica durante os ciclos mastigatórios na mastigação não habitual com Parafilm M® sendo significativo para o músculo temporal direito (p = 0,01). Para a mastigação habitual de alimentos consistentes e macios houve uma maior ativação dos músculos mastigatórios e cervical para o grupo com a doença quando comparado ao grupo controle, sendo significativo para a mastigação habitual com amendoins o músculo temporal direito (p = 0,02), temporal esquerdo (p = 0,03), masseter direito (p = 0,01) e músculo esternocleidomastoideo direito (p = 0,001) e para a mastigação habitual com uvas passas o músculo temporal direito (p = 0,001), temporal esquerdo (p = 0,001), masseter direito (p = 0,001), masseter esquerdo (p = 0,03), esternocleidomastoideo direito (p = 0,001). Baseados nos resultados deste estudo pode-se concluir que em indivíduos com a Doença de Parkinson demonstrou menor eficiência na mastigação não habitual e habitual com alimentos consistentes e alimentos macios quando comparado ao grupo controle. / Parkinson\'s disease is classified as a chronic degenerative and progressive disease, prevalent in individuals from 50 to 70 years of age, being more common in the male gender. It presents as main signs and symptoms the tremor at rest, bradykinesia, muscular rigidity and postural instability, compromising the musculoskeletal chain. This research evaluated the efficiency of masticatory cycles by means of the linear envelope of the electromyographic signal of the masseter, temporal and sternocleidomastoid muscle in individuals with Parkinson\'s disease. Twenty-four participants in the age group between 50 and 70 years old were divided into two groups: Parkinson\'s disease (mean ± SD 66.16 ± 3.37 years, n = 12) and without Parkinson\'s disease (mean ± SD 65.83 ± 3.01 years, n=12). The MyoSystem-I P84 electromyograph was used to evaluate the masticatory cycling efficiency in habitual and non-habitual mastication. Data were tabulated and submitted to statistical analysis (student t test, p <= 0.05). The results showed that the group with Parkinson\'s Disease showed an increase in electromyographic activity during the masticatory cycles during non-habitual mastication with Parafilm M® being significant for the right temporal muscle (p = 0.01). For the usual mastication of consistent and soft foods, there was a greater activation of the masticatory and cervical muscles for the group with the disease when compared to the control group, being significant for the usual chewing with peanuts the right temporal muscle (p = 0.02), (p = 0.01) and right sternocleidomastoid muscle (p = 0.001) and for the habitual mastication with raisins the right temporal (p = 0.001), left temporal = 0.001), right masseter (p = 0.001), left masseter (p = 0.03), right sternocleidomastoid (p = 0.001). Based on the results of this study, it can be concluded that in individuals with Parkinson\'s disease, the efficiency of chewing is unusual and usual with consistent foods and soft foods when compared to the control group.
33

Alterações das atividades eletromiográficas dos músculos masseter e temporal anterior após desprogramação neuromuscular da mandíbula de acordo com a filosofia de Roth / Changes of the electromyographics activities of the masseter and anterior temporal muscles after the mandibular neuromuscular deprogramming according to Roth’s philosophy

Santos, Helena Márcia Guerra dos 07 July 2006 (has links)
As atividades eletromiográficas dos músculos masseter e temporal anterior foram avaliadas em amostra constituída por 37 indivíduos assintomáticos, com maloclusão de Classe I divididos em dois grupos - Experimental e Controle. O grupo Experimental foi composto por 23 indivíduos, sendo 14 do gênero masculino e 9, do feminino, com média de idade de 23 anos e 7 meses, e foi submetido à desprogramação neuromuscular, com o uso de placa oclusal, pelo período médio de 6 meses e 3 dias. O grupo Controle foi formado por 14 indivíduos, sendo 11 do gênero feminino e 3, do masculino, com média de idade de 25 anos e 11 meses, e não fez uso de placa oclusal, nem foi submetido a qualquer intervenção oclusal, no período médio de observação de 8 meses e 10 dias. Os registros eletromiográficos foram realizados por meio de eletrodos bipolares de superfície durante o repouso mandibular e o apertamento oclusal máximo, em dois momentos - T1 e T2. Os valores obtidos foram mensurados pelo cálculo do \"Root Mean Square\" (RMS) e expressos em microvolts (&#956;V). Os índices de assimetria e atividade foram calculados em porcentagem (%). Os dados foram analisados estatisticamente por meio dos testes ANOVA e Bonferroni, considerando-se o nível de significância de 5%. Os resultados mostraram que no grupo Experimental, após o uso da placa oclusal, ocorreu redução significante das atividades eletromiográficas de repouso, assim como aumento significante da atividade eletromiográfica em apertamento oclusal máximo. O grupo controle não mostrou qualquer diferença estatisticamente significante entre os momentos. Os índices de assimetria mostraram que, no repouso mandibular, os músculos do lado esquerdo foram mais ativos. Os índices de atividade mostraram que o músculo temporal anterior apresenta maior contribuição relativa, quando comparado ao masseter, no repouso mandibular. Ambos os índices não sofreram alterações significantes entre os momentos estudados, nos dois grupos. / The electromyographic activity of the muscles masseter and temporal (anterior part) was evaluated in a sample of 37 asymptomatic subjects with Class II malocclusion. They were divided in two groups - experimental and control. The experimental group consisted of 23 subjects, 14 males and 9 females, mean age 23y 7m. This group was neuromuscularly deprogrammed with the use of occlusal splints during a mean period of 6 months and 3 days. The control group was formed by 14 individuals, 3 males and 11 females, mean age 25y 11m. This group did not wear occlusal splint nor suffered any occlusal intervention for a mean observation period of 8 months and 10 days. The electromyographic recordings were accomplished by means of surface bipolar electrodes. The recordings were taken at two different moments - T1 and T2, at mandibular rest position and maximal occlusal clenching. The obtained values were measured by the calculating \"Root Mean Square\" (RMS) and they were expressed in microvolts (&#1094;V). The asymmetry and activity indexes were calculated in percentage (%). The data was statistically evaluated by ANOVA and Bonferroni`s tests, considering the level of significance of 5%. The results showed that in the group that wore the occlusal splint occurred a significant reduction of the eletromyographics activities at rest position, as well as a significant increase of the electromyographics activities at maximal occlusal clenching. The control group did not show any significant change in the observated period. The asymmetry indexes showed at mandibular rest, that the left side muscles were more actives. The activity indexes also showed that the temporal muscle presents a relative greater contribution for the maintenance of the rest mandibular position. The indexes - asymmetry and activity - did not present significant changes between the moments for both groups.
34

Aplicação do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico / Applications of Farc Protocol of TMD treatment with occlusal splint and electromuographic control

Silva, Carolina Amorim Vieira e 10 January 2008 (has links)
A eletromiografia de superfície (EMG) pode ser considerada atualmente um instrumento muito útil, que permite a avaliação quantitativa da musculatura de pacientes com desordem temporomandibular (DTM). O propósito do presente estudo foi aplicar e analisar os efeitos do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico, comparando os dados da avaliação, de 15 pacientes com DTM, classificados segundo o RDC / TMD, antes e após o tratamento; os resultados da EMG obtidos antes, durante e após o uso da placa por 45 dias, pelo grupo com DTM; e comparando os resultados da EMG de uma população com DTM antes e após o tratamento com placa, com um grupo controle. O exame eletromiográfico dos músculos masseter e temporal anterior foi realizado na primeira sessão de avaliação (Etapa 1), após 1 semana (Etapa 2) e após 5 semanas (Etapa 3) de tratamento, servindo para verificar a estabilidade da placa e a evolução da atividade muscular. As ondas da EMG foram analisadas, por meio do software, e os seguintes índices de EMG foram computados: coeficiente de porcentagem de sobreposição (POC) dos músculos masseter e temporal; coeficiente de torque (TORS); índice de assimetria (ASIM), índice de atividade (ATTIV) e o total da atividade elétrica (IMP). Para os dados expressos em nível intervalar de mensuração, foi empregada estatística não-paramétrica, sendo empregado o teste de Wilcoxon para dados pareados nas análises intra-grupo (entre as etapas). Os dados em nível de razão, foram analisados por meio de estatística paramétrica, sendo empregados para as análises intra-grupo o teste t para dados pareados, para as análises entre grupos o teste t para amostras independentes. O nível de significância estabelecido foi de 5%. Após o tratamento, foi encontrada diferença estatística na capacidade de abertura da boca, assim como na remissão da dor a palpação de grande parte da musculatura avaliada e na ATM. Foi obtida diferença significante no valor de POC do masseter e de IMP, imediatamente após o primeiro ajuste da placa. Quando comparada a etapa 1, sem a placa, com a etapa 2, com a placa ajustada, foi obtida diferença significante nos valores de POC do masseter, de ASIM e de IMP. Houve diferença significante entre as etapas 1, sem placa, e a etapa 3, com placa, nos valores de POC dos músculos masseter e temporal, de ASIM, ATTIV e IMP. Durante todo o tratamento não houve diferença significativa nos índices de EMG dos exames realizados sem a placa. Houve diferença estatística entre os grupos DTM e controle no início e ao final do tratamento, sendo observada diferença significante nos valores de EMG para POC de ambos os músculos e ATTIV. A placa oclusal, embora não tenha mostrado mudanças permanentes, mostrou ser efetiva para promover equilíbrio das atividades da EMG durante seu uso, e eficiente no alívio dos sintomas. Os parâmetros de pesquisa com EMG permitiram seu uso no âmbito cientifico na identificação do desequilíbrio neuromuscular, desta forma este instrumento de avaliação permitiu analisar e avaliar de forma objetiva as diferentes etapas de um tratamento tradicional para DTM na prática odontológica e diferenciar pacientes com DTM de indivíduos assintomáticos. / Surface electromyography (EMG) can currently be considered a very useful instrument which allows a quantitative assessment of masticatory muscles in patients with temporomandibular dysfunction (TMD). The purposes of this study was to apply FARC Protocol of TMD treatment with occlusal splint and electromyographic control, correlating the clinical assessment data before and after the treatment with an occlusal splint for a group of 15 patients with TMD, classified according to the RDC / TMD; comparing the results obtained with EMG, before and after treatment with an occlusal splint; comparing the EMG results for this group suffering from TMD and an asymptomatic control group. The electromyographic examination of the masseter and the anterior temporal muscles was carried out in the first assessment session (Phase 1), after one week (Phase 2) and after five weeks (Phase 3) of treatment, aiming at verifying the stability of the splint and the evolution of the muscular activity. The EMG waves were analyzed using the software, and the following EMG indices were calculated: percentage overlapping coefficient (POC) of the masseter and anterior temporal muscles; torque coefficient (TORS); asymmetry index (ASIM); activity index (ATTIV) and the total electrical activity (IMP). For data expressed at measurement interval levels, nonparametric statistics were adopted, using the Wilcoxon test for the paired data in the intra-group analysis (among the phases). Data at ratio level were analyzed through parametric statistical means: paired data t test for intra-group analysis, independent sample t test for among-group analysis. The significance level was established at 5%. After treatment, a statistical significance was found in mouth opening, as well as in the remission in the pain at palpation of a significant portion of the assessed muscles and the TMJ. A significant difference was obtained for the masseter POC and IMP, immediately after the first splint adjustment. When comparing the first phase, without the splint, to the second phase, with the first splint adjustment, a significant difference was observed in the values for masseter POC, ASIM and IMP. There was a significant difference between phase 1, without the splint, and phase 3, with the adjusted splint, for masseter and temporal POC values, ASIM, ATTIV, and IMP. Throughout the entire treatment, there were no significant differences concerning the EMG index in the examinations performed without the splint. There was a statistical significance between the TMD and the control groups in the beginning and in the end of the treatment, with significant differences observed in POC values for both muscles and ATTIV. The occlusal splint, without provoking permanent changes, proved effective to promote the balance of electromyographic activities during its use, and efficient in relieving the symptoms. The EMG parameters allow its scientific use in identifying neuromuscular unbalance, and as such, this assessment tool allowed an objective analysis and evaluation of the different phases of the traditional treatment for TMD in dentistry, differentiating patients with TMD and asymptomatic individuals.
35

Estudo comparativo da espessura do músculo masseter em seres humanos através de exames de tomografia computadorizada e ultrassonografia / Comparative study of the thickness of the masseter muscle in human beings with exams of computerized tomography scan and ultrasonography

Pastore, Gabriel Pires 01 February 2005 (has links)
A articulação tempo-mandibular vem sendo cada vez mais motivo de interesse e pesquisa por parte dos cirurgiões-dentistas, a gama de exames que favorecem o diagnostico dessas patologias é vasta, porém alguns exames são inacessíveis ao paciente ou de difícil interpretação pelo profissional. Neste estudo realizamos o estudo comparativo do músculo masseter em 14 voluntários que foram submetidos a exames de tomografia computadorizada e ultra-sonografia, para mensuração do diâmetro transverso do citado músculo em diferentes posições. Os resultados indicam diferença estatisticamente significante quando comparadas às diferenças da espessura do masseter pelos métodos citados. A realização do exame de ultra-sonografia deve ser realizado de forma criteriosa, seus valores apresentam-se específicos e quando comparados aos valores obtidos na tomografia computadorizada podem traduzir dados importantes para o diagnóstico. A ultra-sonografia como método de diagnóstico para a ATM acrescenta dados que facilitam o diagnóstico precoce lesões que acometem a musculatura mastigatória, além de ser um exame de baixo custo, alta especificidade, não invasivo e realizado em tempo real / The temporo mandibular joint it is being more and more reason interest for researches on the part of the dentistry, the range of exams that favor it I diagnose of those pathologies it is vast, however some exams are inaccessible to the patient or of difficult interpretation for the professional. In this study we accomplished the comparative study of the masseter muscle in 14 volunteers that they were submitted to exams of computerized tomography scan and ultrasonography, for measured of the cross section of the mentioned muscle in different positions. The results indicate difference significant when compared to the differences of the thickness of the masseter by the mentioned methods. The accomplishment of the ultrasonography exam should be accomplished in a discerning way, your values come specific and when compared to the values obtained in the computerized tomography scan they can translate important data for the diagnosis. The ultrasonography as diagnosis method for temporo mandibular joint increases data that facilitate the diagnosis precocious lesions that attack the Thickness musculature, besides being a low cost exam, high specifity, non invasive and accomplished in real time
36

Alterações morfológicas e funcionais no sistema estomatognático decorrentes da ataxia espinocerebelar - análise eletromiográfica, eficiência mastigatória, espessura muscular e força de mordida molar máxima / Morphological and functional changes in the stomatognathic system due to spinocerebellar ataxia - electromyographic analysis, masticatory efficiency, muscle thickness and maximum molar bite force

Ferreira, Bruno 26 January 2018 (has links)
A ataxia espinocerebelar é um transtorno neurológico que se manifesta em vias motoras com perda de coordenação dos movimentos, nistagma, distúrbios no controle postural, da marcha, e disfagia. Este estudo teve como objetivo analisar a atividade eletromiográfica, eficiência mastigatória, espessura dos músculos temporal e masseter e força de mordida molar máxima de indivíduos com ataxia e indivíduos que não apresentavam comprometimentos neurológicos. Foram selecionados 28 indivíduos com idade média de 45± 3 anos, de ambos os gêneros, distribuídos em dois grupos pareados: com ataxia (n=14; GA) e sem a doença, controle (n=14; GC). Os músculos temporais e masseteres bilateralmente foram avaliados com as seguintes ferramentas: eletromiografia de superfície nas condições clínicas que exigiram controle postural da mandíbula e mastigação; ultrassonografia, nas condições de repouso e máxima intercuspidação habitual e avaliação da força de mordida molar máxima (direita e esquerda). Os resultados da eletromiografia normalizada, ultrassonografia e força de mordida molar máxima, foram analisados por meio do teste t para amostras independentes considerando valor p<=0,05. Os resultados evidenciaram maior atividade eletromiográfica dos músculos temporais e masseteres em todas as condições posturais da mandíbula para o grupo GA, com diferença significante para o músculo temporal direito (p=0,01) e temporal esquerdo (p=0,05) em protrusão; lateralidade direita (p=0,02) e lateralidade esquerda (p=0,01). Na mastigação, o grupo GA apresentou menor eficiência dos ciclos mastigatórios, com diferença significante para todos os músculos avaliados (p=0,00). Na espessura muscular observou-se maior espessura nos músculos temporais e masseteres para o grupo GA em todas as condições clínicas, exceto para o músculo masseter direito em repouso que apresentou valores semelhantes ao GC, não havendo diferença estatística significante. Quanto à força de mordida molar máxima, o GA apresentou menor média em ambos os lados com diferença estatística significante (p<=0,05). Este estudo sugere que o sistema estomatognático de indivíduos com ataxia apresentam alterações morfológicas e funcionais, principalmente na atividade eletromiográfica, eficiência mastigatória e força de mordida molar máxima. / Spinocerebellar ataxia is a neurological disorder manifested in motor functions with loss of coordination of movements, nystagmus, disorders in postural control, gait and dysphagia. This study aimed to analyze the electromyographic activity, masticatory efficiency, temporal and masseter muscle thickness and maximal molar bite force of individuals with ataxia and individuals who did not present neurological impairments. We selected 28 individuals with the average age of 45± 3 years, of both genders, distributed in two matched groups: with ataxia (n=14; AG) and without the disease, control (n=14; CG). The temporal muscles and masseters were evaluated bilaterally with the following tools: surface electromyography in clinical conditions that required postural control of the mandible and mastication; ultrasonography, in the conditions of rest and maximum habitual intercuspation and evaluation of the maximum molar bite force (right and left). The results of normalized electromyography, ultrasonography and maximum molar bite force were analyzed statistically by t-test for independent samples considering value p<=0.05. The results showed a higher electromyographic activity of the temporal muscles and masseters in all postural conditions of the mandible for the AG group, with a significant difference for the right temporal (p=0.01) and left temporal muscle (p=0.05) on protrusion; right laterality (p=0.02) and left laterality (p=0.01). In chewing, the AG group presented lower efficiency of the masticatory cycles, with a significant difference for all muscles evaluated (p=0.00). Regarding muscle thickness, a greater thickness was observed in the temporal and masseter muscles for the AG group in all clinical conditions, except for the right masseter muscle at rest, which presented values similar to the CG, with no statistically significant difference. Regarding the maximum molar bite force, AG presented lower average on both sides with a significant statistical difference (p<=0.05). This study suggests that the stomatognathic system of individuals with ataxia presents morphological and functional alterations, mainly in the electromyographic activity, masticatory efficiency and maximum molar bite force.
37

Análise eletromiográfica do músculo masseter em recém-nascidos a termo durante sucção no seio materno, mamadeira e copo / Electromyographic analysis of the masseter muscle in newborns during suction in breast, bottle and cup feeding

França, Ellia Christinne de Lima 02 December 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-10-14T20:24:00Z No. of bitstreams: 2 Dissertação - Ellia Christinne de Lima França - 2013.pdf: 2174155 bytes, checksum: 514acbbd5493b1455db408ce9110387f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-16T18:00:36Z (GMT) No. of bitstreams: 2 Dissertação - Ellia Christinne de Lima França - 2013.pdf: 2174155 bytes, checksum: 514acbbd5493b1455db408ce9110387f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-16T18:00:36Z (GMT). No. of bitstreams: 2 Dissertação - Ellia Christinne de Lima França - 2013.pdf: 2174155 bytes, checksum: 514acbbd5493b1455db408ce9110387f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-12-02 / The literature on orofacial muscle activity in infant feeding with the use of alternative methods for breastfeeding is scarce. When breastfeeding is difficult or impossible during the neonatal period, an analysis of muscle activity can help determine the best method for substituting it to promote the child’s development. The aim of this study was to analyze the electrical activity of the masseter muscle using surface electromyography during suction in term newborns by comparing breastfeeding, bottle and cup feeding. We conducted an observational, cross-sectional analytical study, in the rooming in care at the Materno Infantil Hospital of Goiânia-Goiás. Was carried out on healthy, clinically stable term infants. Muscle activity was analyzed using surface electromyography during breastfeeding, bottle and cup feeding. Root mean square averages (RMS) recorded in microvolts were transformed into percentages (normalization) of the reference value. The three groups were compared by ANOVA; the “stepwise” method of the multiple linear regression analysis tested the model which best defined the activity of the masseter muscle in the sample at a significance level of 5%. Participants were 81 newborns aging 1.4±0.8 days of life,equally distributed among the three groups. RMS values were lower in the bottle (44.2±14.1%) than in the breast feeding (58.3±12.7%) (p=0.003, ANOVA); cup feeding (52.5±18.2%) did not differ (p>0.05). For one gram increase in weight, RMS would increase by 0.010 units. Bottle/cup feeding would reduce RMS by 10.392 units, comparing to breastfeeding. Masseter activity was significantly higher in breastfed newborns, compared to bottle-fed newborns, which presented the lowest RMS values. Masseter activity during cup-feeding stayed in-between breast and bottle feeding, and did not significantly differ from both groups. Cup/bottle feeding significantly predicted a decreased in RMS, compared to breastfeeding. / A literatura sobre a atividade da musculatura orofacial na alimentação de bebês com o uso de métodos alternativos ao aleitamento materno é escassa. A análise da atividade muscular pode ajudar a definir o melhor método substituto do aleitamento materno quando este está dificultado ou impedido no período neonatal, visando beneficiar o desenvolvimento da criança. O objetivo deste trabalho foi analisar a atividade elétrica do músculo masseter por meio da eletromiografia de superfície durante sucção nos recém-nascidos a termo comparando aleitamento materno, mamadeira e copo. Realizou-se um estudo observacional, analítico transversal, no Alojamento Conjunto do Hospital Materno Infantil de Goiânia-Goiás. Incluiuse recém-nascidos saudáveis, a termo, clinicamente estáveis. Avaliou-se a atividade muscular por meio de eletromiografia de superfície durante aleitamento materno, alimentação com mamadeira ou com copo. As médias de root meant square (RMS) registradas em µV foram transformadas em valores percentuais (normalização) do valor de referência. Os três grupos foram comparados por ANOVA; análise de regressão linear múltipla, método “stepwise”, testou o modelo que melhor definisse a atividade do músculo masseter na amostra estudada; observou-se nível de significância de 5%. Participaram 81 recém-nascidos 1,4 ± 0,8 dias de vida, distribuídos igualmente entre os três grupos. Os valores encontrados da atividade do músculo masseter em RMS foram menores em alimentação por mamadeiras (44,2 ± 14,1%) do que no aleitamento materno (58,3 ± 12,7%) (p = 0,003, ANOVA); a alimentação por copo (52,5 ± 18,2%) não diferiu (p> 0,05). Para um aumento de peso em gramas, o valor de RMS aumentaria 0.010 unidades. Alimentação por mamadeira / copo reduziria RMS por 10,392 unidades, em comparação com a amamentação. A maior média percentual da atividade do músculo masseter foi significativamente maior nos recémnascidos amamentados, em comparação com recém-nascidos alimentados por mamadeira, que apresentou os menores valores de RMS. A média percentual da atividade do músculo masseter durante a alimentação por copo ficou entre as médias encontradas no aleitamento materno e na mamadeira, e não diferiu significativamente entre os dois grupos. Copo / mamadeira predisseram significativamente a diminuição da atividade do músculo, em comparação com a amamentação.
38

Efeito da Doença de Parkinson na força de mordida, atividade eletromiográfica e espessura dos músculos masseter, temporal e esternocleidomastoideo / Effect of Parkinson\'s disease on bite force, electromyographic activity and thickness of the masseter, temporal and sternocleidomastoid muscles

Edson Donizetti Verri 01 December 2017 (has links)
Doença de Parkinson é um distúrbio neurológico, crônico e progressivo que promove alterações motoras com acometimento funcional da musculatura estriada esquelética. Este estudo avaliou a força de mordida molar, atividade eletromiográfica e espessura dos músculos temporal, masseter e esternocleidomastoideo de indivíduos com e sem a doença de Parkinson. Participaram 24 indivíduos, faixa etária entre 50 e 70 anos, distribuídos em dois grupos: com a doença de Parkinson, seguindo os estágios I e III de incapacidade da escala de Hoehn e Yahr, média ± DP 66,16 ± 3,37; n = 12 (GP) e sem a doença, média ± DP 65,83 ± 3,01; n = 12 (GC). Foi utilizado o dinamômetro digital Kratos na análise da força de mordida molar máxima direita e esquerda. O eletromiógrafo MyoSystem BR1 foi usado para captação do sinal eletromiográfico nas condições posturais da mandíbula em repouso, lateralidade direita e esquerda, protrusão, apertamento dental em contração voluntária máxima com e sem Parafilm M®. A imagem da espessura muscular foi mensurada por meio do ultrassom Sono Site Titan nas condições de repouso e apertamento dental em contração voluntária máxima. Os dados obtidos foram tabulados e submetidos à análise estatística (SPSS 21.0, teste t de student; p &le;0,05). A atividade eletromiográfica e espessura muscular revelaram diferenças significantes em quase todos os músculos durante as condições posturais mandibulares entre GP e GC (p&le;0,01 e p&le;0,05). Essas diferenças também foram observadas na força de mordida molar máxima direita e esquerda (p&le;0,01). O GP apresentou maior atividade EMG, maior espessura dos músculos temporais, menor espessura dos músculos masseteres e esternocleidomastoideos e menor força de mordida molar máxima. O entendimento de que a doença de Parkinson está associada com a função prejudicada do sistema estomatognático é extremamente importante para os profissionais da área da saúde na tomada de decisões relacionadas ao tratamento funcional reabilitador. / Parkinson\'s disease is a neurological, chronic and progressive disorder that promotes motor alterations with functional impairment of the skeletal striated musculature. This study evaluated the molar bite strength, electromyographic activity, and thickness of the temporal, masseter and sternocleidomastoid muscles of individuals with and without Parkinson\'s disease. Twenty-four individuals, aged between 50 and 70 years old, were divided into two groups: with Parkinson\'s disease, following stages I and III of Hoehn and Yahr disability, mean ± SD 66.16 ± 3.37; n = 12 (GP) and without the disease, mean ± SD 65.83 ± 3.01; n = 12 (GC). The Kratos digital dynamometer was used to analyze the maxillary right and left molar bite force. The MyoSystem BR1 electromyograph was used to capture the electromyographic signal at postural conditions of the resting mandible, right and left laterality, protrusion, maximum voluntary contraction, with and without Parafilm M®. The image of muscular thickness was measured by means of the Sono Site Titan ultrasound in the conditions of rest and dental tightening in maximum voluntary contraction. Data were tabulated and submitted to statistical analysis (SPSS 21.0, student t-test; p&le;0.05). The electromyographic activity and muscle thickness revealed significant differences in almost all muscles during mandibular postural conditions between PG and CG (p&le;0.01 and p&le;0.05). These differences were also observed in the right and left maximal molar bite force (p&le;0.01). The PG presented higher EMG activity, a greater thickness of the temporal muscles, lower thickness of the masseter and sternocleidomastoid muscles, and a lower maxillary bite force. The understanding that Parkinson\'s disease is associated with the impaired function of the stomatognathic system is extremely important for health professionals in making decisions related to functional rehabilitative treatment.
39

Aplicação do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico / Applications of Farc Protocol of TMD treatment with occlusal splint and electromuographic control

Carolina Amorim Vieira e Silva 10 January 2008 (has links)
A eletromiografia de superfície (EMG) pode ser considerada atualmente um instrumento muito útil, que permite a avaliação quantitativa da musculatura de pacientes com desordem temporomandibular (DTM). O propósito do presente estudo foi aplicar e analisar os efeitos do protocolo FARC de tratamento de DTM com placa oclusal e controle eletromiográfico, comparando os dados da avaliação, de 15 pacientes com DTM, classificados segundo o RDC / TMD, antes e após o tratamento; os resultados da EMG obtidos antes, durante e após o uso da placa por 45 dias, pelo grupo com DTM; e comparando os resultados da EMG de uma população com DTM antes e após o tratamento com placa, com um grupo controle. O exame eletromiográfico dos músculos masseter e temporal anterior foi realizado na primeira sessão de avaliação (Etapa 1), após 1 semana (Etapa 2) e após 5 semanas (Etapa 3) de tratamento, servindo para verificar a estabilidade da placa e a evolução da atividade muscular. As ondas da EMG foram analisadas, por meio do software, e os seguintes índices de EMG foram computados: coeficiente de porcentagem de sobreposição (POC) dos músculos masseter e temporal; coeficiente de torque (TORS); índice de assimetria (ASIM), índice de atividade (ATTIV) e o total da atividade elétrica (IMP). Para os dados expressos em nível intervalar de mensuração, foi empregada estatística não-paramétrica, sendo empregado o teste de Wilcoxon para dados pareados nas análises intra-grupo (entre as etapas). Os dados em nível de razão, foram analisados por meio de estatística paramétrica, sendo empregados para as análises intra-grupo o teste t para dados pareados, para as análises entre grupos o teste t para amostras independentes. O nível de significância estabelecido foi de 5%. Após o tratamento, foi encontrada diferença estatística na capacidade de abertura da boca, assim como na remissão da dor a palpação de grande parte da musculatura avaliada e na ATM. Foi obtida diferença significante no valor de POC do masseter e de IMP, imediatamente após o primeiro ajuste da placa. Quando comparada a etapa 1, sem a placa, com a etapa 2, com a placa ajustada, foi obtida diferença significante nos valores de POC do masseter, de ASIM e de IMP. Houve diferença significante entre as etapas 1, sem placa, e a etapa 3, com placa, nos valores de POC dos músculos masseter e temporal, de ASIM, ATTIV e IMP. Durante todo o tratamento não houve diferença significativa nos índices de EMG dos exames realizados sem a placa. Houve diferença estatística entre os grupos DTM e controle no início e ao final do tratamento, sendo observada diferença significante nos valores de EMG para POC de ambos os músculos e ATTIV. A placa oclusal, embora não tenha mostrado mudanças permanentes, mostrou ser efetiva para promover equilíbrio das atividades da EMG durante seu uso, e eficiente no alívio dos sintomas. Os parâmetros de pesquisa com EMG permitiram seu uso no âmbito cientifico na identificação do desequilíbrio neuromuscular, desta forma este instrumento de avaliação permitiu analisar e avaliar de forma objetiva as diferentes etapas de um tratamento tradicional para DTM na prática odontológica e diferenciar pacientes com DTM de indivíduos assintomáticos. / Surface electromyography (EMG) can currently be considered a very useful instrument which allows a quantitative assessment of masticatory muscles in patients with temporomandibular dysfunction (TMD). The purposes of this study was to apply FARC Protocol of TMD treatment with occlusal splint and electromyographic control, correlating the clinical assessment data before and after the treatment with an occlusal splint for a group of 15 patients with TMD, classified according to the RDC / TMD; comparing the results obtained with EMG, before and after treatment with an occlusal splint; comparing the EMG results for this group suffering from TMD and an asymptomatic control group. The electromyographic examination of the masseter and the anterior temporal muscles was carried out in the first assessment session (Phase 1), after one week (Phase 2) and after five weeks (Phase 3) of treatment, aiming at verifying the stability of the splint and the evolution of the muscular activity. The EMG waves were analyzed using the software, and the following EMG indices were calculated: percentage overlapping coefficient (POC) of the masseter and anterior temporal muscles; torque coefficient (TORS); asymmetry index (ASIM); activity index (ATTIV) and the total electrical activity (IMP). For data expressed at measurement interval levels, nonparametric statistics were adopted, using the Wilcoxon test for the paired data in the intra-group analysis (among the phases). Data at ratio level were analyzed through parametric statistical means: paired data t test for intra-group analysis, independent sample t test for among-group analysis. The significance level was established at 5%. After treatment, a statistical significance was found in mouth opening, as well as in the remission in the pain at palpation of a significant portion of the assessed muscles and the TMJ. A significant difference was obtained for the masseter POC and IMP, immediately after the first splint adjustment. When comparing the first phase, without the splint, to the second phase, with the first splint adjustment, a significant difference was observed in the values for masseter POC, ASIM and IMP. There was a significant difference between phase 1, without the splint, and phase 3, with the adjusted splint, for masseter and temporal POC values, ASIM, ATTIV, and IMP. Throughout the entire treatment, there were no significant differences concerning the EMG index in the examinations performed without the splint. There was a statistical significance between the TMD and the control groups in the beginning and in the end of the treatment, with significant differences observed in POC values for both muscles and ATTIV. The occlusal splint, without provoking permanent changes, proved effective to promote the balance of electromyographic activities during its use, and efficient in relieving the symptoms. The EMG parameters allow its scientific use in identifying neuromuscular unbalance, and as such, this assessment tool allowed an objective analysis and evaluation of the different phases of the traditional treatment for TMD in dentistry, differentiating patients with TMD and asymptomatic individuals.
40

FADIGA MUSCULAR: ANÁLISE DOS MÚSCULOS ORBICULARES DA BOCA E MASTIGATÓRIOS DE CRIANÇAS DE 6 A 12 ANOS DE IDADE / MUSCLE FATIGUE: ANALYSIS OF THE ORBICULARIS ORIS MUSCLES AND MASTICATORY MUSCLES OF CHILDREN 6 TO 12 YEARS OF AGE

Stella, Angela Ruviaro Busanello 22 April 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This research aimed to study the fatigue of the orbicularis oris muscles and masticatory muscles, by analyzing the median frequency of the electromyographic signal, considering the breathing mode, the facial growth pattern and age. Also aimed to compare fatigue by electromyographic evaluation with referred fatigue time by children. For this purpose, were selected 70 children between six and 12 years old, of both sexes, that suited the study criteria. Underwent speech, cephalometric, otorhinolaringology, dentistry and body mass index. Electromyographic evaluation was performed in two evaluation protocols. Protocol of the orbicularis oris muscles, children should hold dumbbells lip 40, 60 and 100gr as well as lip exerciser until the feeling of fatigue these muscles. As for the masticatory muscles, the children should chewing gum portion and positioned bilaterally in the oral cavity to the feeling of fatigue these muscles. Subsequently, the median frequency analysis was performed on four different times for each musculature, 5, 10, 15 and 20 seconds for the orbicularis oris muscle, and 15, 30 , 45 and 60 seconds for the masticatory muscles. Were also recorded the referred fatigue time to as fatigue by children. Data were analyzed by ANOVA - repeated measures (post - hoc Tukey), Kruskal-Wallis test and Mann- Whitney U test. As results showed that: the orbicularis oris muscles showed a significant decrease in the median frequency farrowing the five seconds of activity, but regardless of the comparison between groups; when were made these comparison, muscles studied, in their respective protocols, showed no significant decrease; the reported time to the feeling of muscles orbicularis oris fatigue was lower in mouth breathers and children of age group one. When comparing orbicularis oris and masticatory muscles fatigue by electromyography and the reporting of children, in all groups, the perception occurred after the decrease of the median frequency. Thus, it is concluded that the physiological fatigue of the muscles was not influenced by breathing mode, the facial growth pattern, the association of them and age group, but the perception of muscles orbicularis oris fatigue was influenced by the breathing mode and age. The physiological fatigue of the orbicularis oris muscles preceded the reporting of fatigue time. Although there was no physiological fatigue for masticatory muscle, occurred the reporting of fatigue these muscles. / Esta pesquisa teve como objetivo estudar a fadiga dos músculos orbiculares da boca e mastigatórios, por meio da análise da frequência mediana do sinal eletromiográfico, considerando o modo respiratório, o padrão facial de crescimento e a faixa etária. Ainda objetivou comparar a fadiga pela avaliação eletromiográfica com o tempo de fadiga referido pelas crianças. Para tanto, foram selecionadas 70 crianças entre seis e 12 anos de idade, de ambos os sexos, que se adequaram aos critérios do estudo. As mesmas passaram por avaliação fonoaudiológica, cefalométrica, otorrinolaringológica, odontológica e de índice de massa corporal. Foi realizada avaliação eletromiográfica em dois protocolos de avaliação. Para protocolo dos músculos orbiculares da boca, as crianças deveriam sustentar halteres labiais de 40, 60 e 100gr, bem como exercitador labial, até a sensação de fadiga desta musculatura. Já para os mastigatórios, deveriam mascar goma em porção padronizada e posicionada bilateralmente na cavidade oral até a sensação de fadiga. Posteriormente foi realizada a análise da frequência mediana, em quatro tempos para cada musculatura, 5, 10, 15 e 20 segundos para os músculos orbiculares da boca e 15, 30, 45 e 60 segundos para os mastigatórios. Também foi registrado o tempo de fadiga referido pelas crianças. Os dados foram analisados pelos testes ANOVA - medidas repetidas (post-hoc Tukey), teste Kruskal-Wallis e teste U de Mann-Whitney. Como resultados observou-se que: os músculos orbiculares da boca demonstraram decréscimo significativo da frequência mediana a parir dos cinco segundos de atividade, mas independentemente da comparação entre os grupos; quando realizada a comparação entre os grupos, os músculos estudados não demonstraram decréscimo significativo; o tempo relatado para a sensação de fadiga muscular dos orbiculares da boca foi menor nos respiradores orais e nas crianças da faixa etária um. Ao comparar a fadiga muscular, pela eletromiografia e pelo relato das crianças, em todos os grupos a percepção ocorreu após o decréscimo da frequência mediana. Assim, conclui-se que a fadiga fisiológica dos músculos avaliados não sofreu influência do modo respiratório, padrão facial de crescimento, da associação dos mesmos e da faixa etária, mas a percepção da fadiga dos músculos orbiculares sofreu influência do modo respiratório e da faixa etária. A fadiga fisiológica dos músculos orbiculares precedeu o relato do tempo de fadiga. Embora não tenha ocorrido a fadiga mastigatória fisiológica, ocorreu o relato de fadiga desta musculatura.

Page generated in 0.0838 seconds