• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • Tagged with
  • 43
  • 21
  • 10
  • 10
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Aspectos radiológicos e dose de radiação em mamografia de mulheres com implantes mamários / Radiological aspects and radiation dose in augmentation mammography

Couto, Lilian Soares 23 February 2017 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-03-06T13:16:04Z No. of bitstreams: 2 Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-06T14:55:49Z (GMT) No. of bitstreams: 2 Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-06T14:55:49Z (GMT). No. of bitstreams: 2 Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-23 / The main test for early detection of breast cancer is mammography. In the last decade, there was a significant increase in the number of women undergoing mammography for screening of breast cancer and have breast implants. Despite the mammographic screening recommended for patients with implants, follow the same range as recommended for patients doesn’t have implants, routinely includes images with posterior displacement of the implant (ID), known as Eklund’s maneuver, adding four views in relation to who do not have it. This study aimed to evaluate the mammographic characteristics of the required views and the dose that these patients have received in the examination. Data collection was divided into two stages: the first, for radiological evaluation of images and the second for data collection of radiographic techniques for image production. The radiological evaluation was performed by radiologists, with experience in mammography reading, who independently answered a questionnaire about: 1) implant position, 2) overall improvement image, 3) amount of breast tissue seen in the maneuver in relation to the standard images, 4) if there were findings in the exams, e) which view these findings were seen. For the data of the mammographic techniques, from the records in the DICOM (Digital Imaging and Communications in Medicine) heading of each image were collected: voltage (kV) and current x time (mAs) emitted by the device, target/filter combination, breast thickness and mean glandular dose (DGM). The data were analyzed by means of statistical treatment. Regarding the radiological evaluation, the evaluators agreed that the amount of breast tissue in the in the ID views depends on the position of the implant and is smaller in the retroglandular position. There was a significant increase in the quality of the images with the displacement of the implant and there were no findings seen in the exams, which were not seen in those views. Regarding the radiation doses received by patients with implants, during the mammographic examination, the DGM exceeds the limit recommended by the agencies responsible for the protocols. This study suggests the need for continuity of the research, with an increase in the sample and optimization of the mammographic technique, in order to evaluate the risk benefit ratio of maintaining all views of augmentation mammograms. / O principal exame para detecção precoce do câncer de mama é a mamografia. Na última década, houve um crescimento expressivo do número de mulheres que realizam mamografia para o rastreamento do câncer de mama e possuem implantes mamários. Apesar do rastreamento mamográfico recomendado para as pacientes com implantes, seguir o mesmo intervalo que o preconizado para as pacientes que não possuem, inclui de rotina, imagens com deslocamento posterior do implante, conhecida como manobra de Eklund, adicionando-se quatro incidências em relação às que não possuem. Este trabalho propôs-se à avaliação das características mamográficas das incidências exigidas e da dose de radiação que estas pacientes têm recebido no exame. A coleta de dados foi dividida em duas etapas: a primeira, para avaliação radiológica das imagens e a segunda para levantamento dos dados das técnicas radiográficas para produção das imagens. A avaliação radiológica foi realizada por médicos radiologistas, com experiência em leitura de mamografias, que responderam de forma independente um questionário sobre: 1) posição do implante, 2) melhoria global em detalhe de imagem, 3) quantidade de tecido mamário visto na manobra de Eklund em relação as imagens padrões, 4) se houve alteração nos exames, e) em quais incidências estas alterações foram vistas. Para os dados das técnicas mamográficas, foram coletados, a partir dos registros no cabeçalho DICOM (Digital Imaging and Communications in Medicine) de cada imagem: tensão (kV) e corrente x tempo (mAs), combinação alvo/filtro, espessura da mama e dose glandular média (DGM). Os dados foram analisados por meio de tratamento estatístico. Em relação à avaliação radiológica, os avaliadores concordaram que a quantidade de tecido mamário nas imagens com deslocamento do implante, depende da posição em que o implante se encontra, sendo menor na posição retroglandular. Houve significativo aumento da qualidade das imagens com o deslocamento do implante e não houve nenhuma alteração vista nos exames, que não tenham sido visibilizadas nas imagens com a manobra. Quanto às doses de radiação recebidas pelas pacientes com implantes, durante o exame mamográfico, a DGM excede o limite preconizado pelas agências responsáveis pelos protocolos. Este estudo sugere a necessidade de continuidade da pesquisa, com incremento da amostra e otimização da técnica mamográfica, para que se possa avaliar, a relação benefício risco de se manter todas as incidências em mamografias de mulheres com implantes mamários.
22

Caracterização molecular de fibroblastos originários de tecido mamário neoplásico ou não e modificação do perfil gênico após interação com células epiteliais mamárias normais / The homeostasis of normal breast depends on interactions...

Patricia Bortman Rozenchan 05 April 2005 (has links)
A homeostase da mama normal depende das interações entre células epiteliais e o estroma a elas associado. Estudos anteriores mostraram que no carcinoma mamário o estroma é constituído por células com diferentes funções. Estes elementos do estroma incluem fibroblastos, os quais modulam o comportamento tumoral, fornecendo fatores de crescimento e componentes de matriz extracelular. Nosso objetivo foi investigar a expressão gênica diferencial entre fibroblastos derivados de tecido mamário neoplásico ou não neoplásico e analisar a influência de células epiteliais normais (MCF10A) no perfil de expressão gênica de fibroblastos obtidos de tecido mamário neoplásico. Culturas primárias de fibroblastos foram estabelecidas e a expressão de vimentina e actina de músculo liso foi positiva. Foi realizada a co-cultura destas células com separação por insertos, o que permite a passagem de fatores solúveis, e o RNA foi extraído. Após a amplificação do RNAm foram sintetizadas sondas de cDNA, as quais foram marcadas com fluorocromos conjugados a deoxinucleotídeo, hibridizadas competitivamente sobre lâminas de vidro contendo 4.608 ORESTES criadas no Instituto Ludwig de Pesquisa sobre o Câncer/FAPESP e os sinais fluorescente gerados foram quantificados. Após a normalização destes dados, os genes diferencialmente expressos, com False Discovery Ratio (FDR) menor que 0,05, foram selecionados para análises posteriores. Encontramos 283 genes diferencialmente expressos em fibroblastos derivados de tecido mamário neoplásico quando comparados àqueles derivados de tecido mamário não-neoplásico. Dentre estes genes, 187 foram quantitativamente regulados negativamente (com variação de expressão de 1,05 a 4,14) contra 96 regulados positivamente (variação de expressão de 1,17 a 7,73). A maioria destas alterações foram relacionadas ao transporte entre membranas, transdução de sinal e biosíntese. Estes resultados podem sugerir uma redução na expressão gênica durante o processo de transformação. Após a co-cultura com células MCF10A, encontramos 566 genes diferencialmente expressos nos fibroblastos derivados de tecido mamário neoplásico, 323 foram regulados negativamente (expressão variando de 1,09 a 10,62) e 243 regulados positivamente (variação de expressão de 1,03 a 16,62). A influência das células MCF10A na expressão gênica destes fibroblastos pôde ser vista através da desregulação da expressão de genes relacionados com a proliferação celular, adesão, apoptose e sobrevivência. / The homeostasis of normal breast depends on interactions between epithelial cells and their associated stroma. Previous studies indicated that in breast cancer carcinoma, tumor associated stromal cells with different functions appear to be emerged. These stromal elements include fibroblasts which modulate tumor behavior providing various growth factors and extracellular matrix components. Our aim was to evaluate the differential gene expression between fibroblasts derived from mammary tissue neoplasic or not and to analyze the influence of normal epithelial cells (MCF10A) on gene expression profile of fibroblasts obtained from neoplasic mammary tissue. Fibroblast primary cultures were established and expression of vimentin and smooth cell actin was positive. Co-culture of these cell types separated by inserts, which allow the passage of soluble factors, was done and total RNA was extracted. After mRNA amplification using a template-switching prime, cDNA probes were synthesized, labeled with fluorochrome conjugated deoxynucleotide, a competitive hybridization was undertaken onto cDNA microarray glass slides in which 4,608 ORESTES (open reading frame expressed sequence tags) from Instituto Ludwig de Pesquisa sobre o Câncer/FAPESP bank were spotted and fluorescent signals were quantified. After normalization, the differentially expressed genes, at a False Discovery Ratio (FDR) less then 0.05, were selected for further analysis. We found 283 differentially expressed genes in fibroblasts obtained from neoplasic mammary tissue when compared with non neoplasic derived fibroblasts. Among these genes, 187 were quantitatively down regulated (fold ranging from 1.05 to 4.14) against 96 up regulated (fold ranging from 1.17 to 7.73). The majority of alterations were related to membrane transport, signaling transduction and biosynthesis. Overall these results could suggest a reduced gene expression along transformation process After coculture with MCF10A cells, we found 566 differentially expressed genes in neoplasic mammary tissue derived fibroblasts, 323 were down regulated (fold ranging from 1.09 to 10.62) and 243 up regulated (fold ranging from 1.03 to 16.62). MCF10A influence in mammary tissue neoplasic derived fibroblasts gene expression could be seen trough the deregulation of expression of some genes possibly related cell proliferation, adhesion, apoptosis and survival.
23

Análise da expressão de receptor de estrógeno e da distribuição de macrófagos nos tumores mamários caninos /

Melo, Tawane Agda Lopes de January 2019 (has links)
Orientador: Maria Cecília Rui Luvizotto / Coorientador: Heitor Flávio Ferrari / Banca: Daniela Bernadete Rozza / Banca: Livia Castanhas Breganó / Resumo: O tumor mamário canino (TMC) é a neoplasia que mais comumente acomete cadelas idosas não castradas. Na análise histopatológica, 41 a 53% dos TMCs são classificados como malignos. Os receptores de estrógeno α (REα) são receptores nucleares importantes na transcrição de fatores e transdução de sinais hormonais, considerados um dos fatores prognósticos para o tumor mamário humano, participam de forma ativa na carcinogênese mamária. Durante o desenvolvimento do TMC, macrófagos teciduais compõe o microambiente tumoral, com a função de estimular a angiogênese, aumentando a possibilidade de metástases, sendo fundamental para o prognóstico de neoplasia mamária na cadelae na mulher. O objetivo deste trabalho foi pesquisara expressão e a provável correlação de REα com a distribuição de macrófagos tumorais (TAMs) em TMCs por meio de imunohistoquímica. Foram analisados 40 tumores mamários malignos, classificados histologicamente em quatro grupos distintos e um grupo controle composto por 08 glândulas mamárias caninas sem alteração anatomopatológica e seus respectivos linfonodos regionais. Os resultados mostraram que a imunomarcação positiva ao REα variou de um a três casos dentre os grupos histológicos estudados, havendo nestes, menor número de metástase para linfonodo. A positividade para os TAMs mostrou associação com o tipo histológico, variando de moderada a acentuada nos carcinomas mamários de alto grau histológico que apresentaram necrose, invasão linfática e formação tubular. Não ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The canine mammary tumor (CMT) is the neoplasia that most commonly affects uncastrated elderly female dogs. On histopathological analysis, 41 to 53% of CMTs are classified as malignant. Estrogen receptors α (REα) are important nuclear receptors for transcription factors and signal transduction of hormones, considered prognosis factor for breast cancer in human, and recognized as actively involved in breast carcinogenesis. During the development of mammary cancer in canine species, macrophages composes the tumor microenvironment, stimulating angiogenesis, facilitating the local dissemination of neoplastic cells and increasing the possibility of metastasis, being fundamental for mammary neoplasia prognosis in dogs and women. This study aimed to evaluate the expression and the probable correlation of REα with the distribution of tumor associated macrophages (TAMs) in CMTs by immunohistochemistry. Forty CMTs were analyzed histologically in four distinct groups and a control group composed of eight canine mammary glands without alteration anatomopathological and their respective regional lymph nodes. The results showed that the REα positive immunostaining varied from one to three cases among the histological groups studied, and there was less lymph node metastasis. The positivity for TAMs showed a positive correlation with the histological type, ranging from moderate to severe in mammary carcinomas of high histological grade that presented necrosis, lymphatic invasion and tubular ... (Complete abstract click electronic access below) / Mestre
24

Segmentação de imagens ultrassonográficas para detecção de nódulos / Segmentation of ultrasound images to detect nodules

Ramos, Paula Zitko Alves 14 April 2010 (has links)
O câncer de mama é um dos maiores problemas de saúde para a população feminina, devendo ser encarado como um importante problema de saúde pública. A ultrassonografia é considerada o método mais efetivo na complementação de diagnóstico de doenças mamárias, porém a forma de aquisição desse método diagnóstico degrada a imagem sob diversas formas, destacando-se o ruído speckle, o qual deixa a imagem com aspecto granulado, dificultando assim a separabilidade entre os objetos da cena. Este trabalho apresenta uma técnica automática para segmentação de nódulos mamários em imagens de ultrassom. O algoritmo permite a extração das bordas nodulares, permitindo assim a obtenção de parâmetros clínicos utilizados no diagnóstico mamário. Todo o processo se baseia em três etapas: minimização do ruído speckle, aumento de contraste da imagem e por fim, a segmentação. A técnica utilizada para minimização do ruído speckle baseia-se na Wavelet da família Symlet; técnicas para aumento de contraste na imagem são aplicadas para a segmentação. A partir daí, é aplicado o algoritmo de segmentação Asterisco, originalmente proposto para a detecção de microcalcificações em mamografias por raios X, e que mostrou também eficiência para os objetivos deste trabalho. A técnica Asterisco em conjunto com as de pré-processamento (minimização de ruído e aumento de contraste) produziu taxa de sensibilidade na detecção de nódulos da ordem de 90%. Em relação à qualidade da segmentação, a técnica apresentada neste trabalho também se mostrou satisfatória, superior às técnicas testadas, de acordo com a análise feita pelo cálculo de coeficientes de correlação de Pearson. É possível concluir que o sistema desenvolvido neste trabalho pode constituir-se numa ferramenta eficaz de segmentação de nódulos mamários em imagens de ultrassom, auxiliando o conjunto de informações disponíveis para um classificador automático em esquemas CAD em mamografia. / Breast cancer is one of the main health problems of the female population and should be faced as an important public health care issue. The ultrasound scanning is considered the most effective in complementary method of breast diagnosis. Nevertheless, the acquisition format of this sort degrades the images in various ways, being the speckle noise of noticeably influence once it leaves the image with grainy aspect. Therefore, the separability between objects of the scene is hindered. This work presents an automatic technique of ultrasound image segmentation of breast lumps. The algorithm allows the extraction of the nodular edges permitting the clinical parameters to be obtained for the breast diagnosis. All the process is based on three steps: speckle noise minimization, image contrast intensification and finally the segmentation. The technique used on the speckle noise minimization is based on the Wavelet transform of the Symlet family; image contrast intensifications are applied for the segmentation. Thereafter the algorithm of segmentation Asterisco is applied, which is originally proposed to detect micro calcifications in X-ray mammography, and has also shown efficiency regarding the goals of the present work. The Asterisco technique along with the pre processing techniques (noise minimizing and contrast intensification) produced sensitivity rate in nodule detection by 90%. With regard to the segmentation quality, the presented technique has also proved to be satisfactory as it has superior quality to the ones tested according to the analysis made by the Pearson\'s correlation coefficients calculation. Thus, it is possible to conclude that the system, which has been developed in this work, can constitute an efficient breast lumps segmentation tool so as to aid the set of available information to an automatic classifier in mammography CAD schemes.
25

Redução da biocarga e garantia de esterilidade em implantes mamários de silicone / Bioburden reduction and sterility assurance in silicone gel breast implants

Santos, Glaucia Cristina Mello 16 December 2009 (has links)
Os implantes mamários de silicone constituem-se em biomateriais os quais têm sido amplamente utilizados em cirurgias para reconstituição da mama após ocorrência de câncer, acidentes, correção do tamanho dos seios quando há uma diferença de volume entre eles, ou até mesmo, para o aumento do tamanho da mama por motivos estéticos. Com o intuito de conferir segurança em sua aplicação, intimamente ligada à saúde dos pacientes, grande atenção tem sido dada aos processos de esterilização aplicados a biomateriais. Ao avaliar o processo produtivo de implantes mamários de silicone, um dos processos de esterilização mais comumente empregados é o calor seco, que necessita de elevadas temperaturas por longo tempo para o sucesso da esterilização. A exposição do implante a tais condições potencialmente pode ocasionar alterações de suas características. De outro lado, uma etapa preliminar do processo produtivo do implante é a vulcanização, que consiste no aquecimento do implante a temperaturas da ordem de 165 ± 5°C por aproximadamente 9 horas. Considerando tempo e temperatura empregados nesta etapa, o objetivo deste estudo foi avaliar a carga microbiana dos implantes mamários de silicone antes do processo de vulcanização, assim como o decaimento da carga microbiana neste processo e também confirmar a esterilidade do gel contido internamente à membrana. Desta forma, foi possível observar que o nível de contaminação microbiana dos implantes gelatinosos é relativamente baixo e que a vulcanização foi um processo que possibilitou a inativação de até 108 esporos, a concentração de esporos mais alta utilizada no estudo. Os resultados mostraram que a vulcanização possibilitou não só a redução da carga microbiana, mas também consiste em mecanismo para garantir a esterilidade do gel interno ao produto. Desta forma, o processo esterilizante final teve como contribuição elevar o Nível de Garantia de Esterilidade (SAL ou Sterility Assurance Level), condição interessante ao se considerar a tendência de adoção da liberação paramétrica, assim como o conceito de validação combinado bioburden/indicador biológico em vez de sobre-morte. Avaliação complementar foi feita ao quantificar endotoxina nos implantes antes e após o processo de esterilização (calor seco e óxido de etileno), verificando-se que os processos considerados não alteram significativamente a quantidade de endotoxina. Ainda assim, em todas as situações foram obtidos níveis aceitáveis, conforme USP 31. / Silicone breast implants consist of biomaterials widely used in breast reconstitution surgeries after the occurrence of cancer, accidents, breast size correction (in case of different volume between both breasts)or in mammary augmentation for esthetic reasons. With a view to confer security in its application, directly related to patients health, great attention has been given to sterilization processes applied to biomaterials. Among these, dry heat is one of the most often employed. For a successful sterilization, it requires high temperatures for a long period, what may give rise to alteration of the implant characteristics. On the other hand, a preliminary stage of the implant production process is vulcanization, which consists of heating the implant to 165 ± 5°C for approximately 9 hours. Taking into account the time and temperature used in this stage, the aim of this work was to evaluate the bioburden of silicone breast implants prior to the vulcanization process and the decline in bioburden due to this process, and to confirm the sterility of the gel contained in the membrane. This study led us to the conclusion that the level of microbial contamination of gel implants is relatively low, and that vulcanization allowed for the inactivation of up to 100 million spores, the highest concentration of spores used in this study. The results obtained showed that vulcanization enabled not only the reduction of the microbial load, but also guaranteed the sterility of the gel inside the product. Thus, the final sterilizing process contributed to an increase in the Sterility Assurance Level, an interesting phenomenon if we consider the tendency toward adoption of parametric release and the concept of a combined validation bioburden/biological indicator rather than overkill. Complement evaluation was made measuring endotoxins in the implants before and after the sterilization process (dry heat and ethylene oxide), verifying that the considered processes do not modify the amount of endotoxin significantly, as expectation. Still thus, in all the situations had been gotten acceptable levels, as USP 31.
26

Redução da biocarga e garantia de esterilidade em implantes mamários de silicone / Bioburden reduction and sterility assurance in silicone gel breast implants

Glaucia Cristina Mello Santos 16 December 2009 (has links)
Os implantes mamários de silicone constituem-se em biomateriais os quais têm sido amplamente utilizados em cirurgias para reconstituição da mama após ocorrência de câncer, acidentes, correção do tamanho dos seios quando há uma diferença de volume entre eles, ou até mesmo, para o aumento do tamanho da mama por motivos estéticos. Com o intuito de conferir segurança em sua aplicação, intimamente ligada à saúde dos pacientes, grande atenção tem sido dada aos processos de esterilização aplicados a biomateriais. Ao avaliar o processo produtivo de implantes mamários de silicone, um dos processos de esterilização mais comumente empregados é o calor seco, que necessita de elevadas temperaturas por longo tempo para o sucesso da esterilização. A exposição do implante a tais condições potencialmente pode ocasionar alterações de suas características. De outro lado, uma etapa preliminar do processo produtivo do implante é a vulcanização, que consiste no aquecimento do implante a temperaturas da ordem de 165 ± 5°C por aproximadamente 9 horas. Considerando tempo e temperatura empregados nesta etapa, o objetivo deste estudo foi avaliar a carga microbiana dos implantes mamários de silicone antes do processo de vulcanização, assim como o decaimento da carga microbiana neste processo e também confirmar a esterilidade do gel contido internamente à membrana. Desta forma, foi possível observar que o nível de contaminação microbiana dos implantes gelatinosos é relativamente baixo e que a vulcanização foi um processo que possibilitou a inativação de até 108 esporos, a concentração de esporos mais alta utilizada no estudo. Os resultados mostraram que a vulcanização possibilitou não só a redução da carga microbiana, mas também consiste em mecanismo para garantir a esterilidade do gel interno ao produto. Desta forma, o processo esterilizante final teve como contribuição elevar o Nível de Garantia de Esterilidade (SAL ou Sterility Assurance Level), condição interessante ao se considerar a tendência de adoção da liberação paramétrica, assim como o conceito de validação combinado bioburden/indicador biológico em vez de sobre-morte. Avaliação complementar foi feita ao quantificar endotoxina nos implantes antes e após o processo de esterilização (calor seco e óxido de etileno), verificando-se que os processos considerados não alteram significativamente a quantidade de endotoxina. Ainda assim, em todas as situações foram obtidos níveis aceitáveis, conforme USP 31. / Silicone breast implants consist of biomaterials widely used in breast reconstitution surgeries after the occurrence of cancer, accidents, breast size correction (in case of different volume between both breasts)or in mammary augmentation for esthetic reasons. With a view to confer security in its application, directly related to patients health, great attention has been given to sterilization processes applied to biomaterials. Among these, dry heat is one of the most often employed. For a successful sterilization, it requires high temperatures for a long period, what may give rise to alteration of the implant characteristics. On the other hand, a preliminary stage of the implant production process is vulcanization, which consists of heating the implant to 165 ± 5°C for approximately 9 hours. Taking into account the time and temperature used in this stage, the aim of this work was to evaluate the bioburden of silicone breast implants prior to the vulcanization process and the decline in bioburden due to this process, and to confirm the sterility of the gel contained in the membrane. This study led us to the conclusion that the level of microbial contamination of gel implants is relatively low, and that vulcanization allowed for the inactivation of up to 100 million spores, the highest concentration of spores used in this study. The results obtained showed that vulcanization enabled not only the reduction of the microbial load, but also guaranteed the sterility of the gel inside the product. Thus, the final sterilizing process contributed to an increase in the Sterility Assurance Level, an interesting phenomenon if we consider the tendency toward adoption of parametric release and the concept of a combined validation bioburden/biological indicator rather than overkill. Complement evaluation was made measuring endotoxins in the implants before and after the sterilization process (dry heat and ethylene oxide), verifying that the considered processes do not modify the amount of endotoxin significantly, as expectation. Still thus, in all the situations had been gotten acceptable levels, as USP 31.
27

Ensaio de fadiga e resistência ao impacto para avaliação de conformidade de implantes mamários

Cé, Nataly Araújo January 2013 (has links)
A partir de um alerta internacional emitido pelas autoridades sanitárias francesas no ano de 2010 com respeito a altas taxas de ruptura de implantes mamários da marca Poly Implant Prothèse (PIP), a Agência de Vigilância Sanitária brasileira (ANVISA) suspendeu a importação, distribuição, comércio e uso destes implantes no país. Visando manter a qualidade destes produtos no mercado brasileiro, a partir de março de 2012 – conforme publicado pelo Instituto Nacional de Metrologia (INMETRO) – foi instituída a certificação compulsória dos implantes mamários e em seguida definidos os ensaios através dos quais os implantes mamários devem ter sua conformidade avaliada, sendo esses ensaios mecânicos e químicos. Este trabalho apresenta o desenvolvimento de equipamentos e metodologia para avaliação da conformidade de dois ensaios mecânicos em implantes mamários: ensaio de fadiga e ensaio de resistência ao impacto. Duas normas foram utilizadas para o processo de acreditação: ISO 14607 – Non - active surgical implants – Mammary implants – Particular Requirements, e ABNT NBR ISO 14607 – Implantes cirúrgicos não ativos – Implantes mamários – Requisitos particulares. Os equipamentos utilizados foram desenvolvidos e construídos ao longo do desenvolvimento deste estudo e os testes foram realizados em implantes mamários da marca PIP obtidos junto a ANVISA. A primeira etapa consistiu em organizar os documentos necessários para acreditação junto ao INMETRO e, após, ensaios os ensaios foram realizados. Ao todo trinta e cinco implantes foram ensaiados – 31 na primeira parte do trabalho e 04 na segunda – e analisados em lupa para verificação de defeitos causados pelos testes como: fraturas, cortes, alteração de forma, entre outros. Os equipamentos e metodologia desenvolvida atendem os requisitos de ambas as normas e permitem avaliação de conformidade de próteses mamárias comercializadas no país, no que diz respeito ao ensaio de fadiga e resistência ao impacto. / Due an international alert issued by French authorities in 2010 regarding high rupture rate of breast implants related to Poly Implant Prothèse (PIP), the Brazilian Health Surveillance Agency has suspended the importation, distribution, commercialization and use of these implants into Brazil. In order to maintain the quality of these products in Brazilian market, on March 2012 – according published by National Institute of Metrology – it has been decided for compulsory certification of breast implants and then defined the tests through which these products have to be submitted for its conformity assessment, being these mechanical and chemical tests. This dissertation evaluates the development and methodology for conformity assessment of two mechanical tests on breast implants: fatigue and impact resistance test. The process was based on two standards: ISO 14607 and ABNT NBR ISO – Non - active surgical implants – Mammary implants – Particular Requirements. The equipment used was developed in the laboratory during the realization of this study and the tests were performed on implants produced by PIP provided by National Sanitary Surveillance Agency. It started with the organization of the documents to be sent to National Institute of Metrology, in order to ask the accreditation and then tests were performed. Thirty five implants were tested – 31 on first part of the work and 04 on the second one – and then analyzed to detect any anomaly that could be considered a defect such as: rupture, cuts, shape alteration, etc. The equipment and methodology has met the requirements from both standards and enable conformity assessment of breast implants commercialized in Brazil, regarding to fatigue and impact resistance tests.
28

Perfil hormonal e avaliação ultrassonográfica hemodinâmica da glândula mamária de búfalas em diferentes categorias

Dantas, Ariane January 2016 (has links)
Orientador: Eunice Oba / Resumo: O objetivo do presente trabalho foi delinear parâmetros hemodinâmicos e avaliar sua relação com os principais hormônios envolvidos na mamogênese de búfalas mestiças Murrah em diferentes estágios fisiológicos. Utilizou-se 24 animais separados de acordo com a categoria (n= 6): bezerras, novilhas, gestantes e lactantes, com idades iniciais de zero, 12, 24 e 48 meses, respectivamente, criadas extensivamente. Realizou-se a cada 28 dias, ultrassonografia Doppler, colheita de sangue e pesagem, durante um ano (bezerras e novilhas) e 10 meses (gestantes e lactantes). Foram determinados os índices de resistividade (IR) e pulsatilidade (IP) e o diâmetro interno (DI) das artérias mamárias pela ultrassonografia. Foram mensuradas as concentrações plasmáticas de progesterona (P4), fator semelhante a insulina tipo I (IGF-I), insulina (IN), hormônio do crescimento (GH) e estradiol (17β-E2). Utilizou-se ANOVA com medidas repetidas, correlação de Spearman e regressão não linear múltipla, considerando nível de significância de 0,05. Nas bezerras e novilhas, houve redução de IR e IP e aumento do DI (P<0,0001) do primeiro ao último mês de avaliação, contudo, não houve diferença estatística para os índices hemodinâmicos entre as artérias mamárias cranial e caudal. Nas bezerras, detectou-se correlação do IR com o IP (r= 0,94; P<0,0001) e com o DI (r= -0,98; P<0,0001) e também, do IP com o DI (r= -0,98; P<0,0001). Nas novilhas o IR também correlacionou-se com o IP (r= 0,99; P<0,000... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to delineate hemodynamic parameters and toevaluate its relationship with key hormones involved in mammogenesis ofcrossbred Murrah buffaloes in different physiological stages. We used 24 animalsdivided according to the category (n= 6): calves, heifers, pregnant and lactatingfemales with early ages of zero, 12, 24 and 48 months, respectively, raisedextensively. Every 28 days, Doppler ultrasound examinations, blood analysis andweighing were held over one year (for calves and heifers) and over 10 months(for pregnant and lactating females). There were determined resistivity index (RI)and pulsatility index (PI) and internal vessel diameter (ID) of the mammaryarteries by ultrasound. Plasma concentrations of progesterone (P4), insulin-likegrowth factor 1 (IGF-I), insulin (IN), growth hormone (GH) and estradiol (17β-E2)were measured. We used repeated measures ANOVA, Spearman correlationand non-linear multiple regression considering 0.05 significance level. In calvesand heifers, a reduction of RI and PI and increased ID (P<0.0001) from first tolast month's assessment, however, there was no statistical difference inhemodynamic indices between the cranial and caudal mammary arteries. Allheifers, RI correlation was detected with PI (r= 0.94; P<0.0001), and ID (r= -0.98;P<0.0001) and also PI with ID (r= -0.98; P<0.0001). In heifers RI also correlatedwith PI (r= 0.99; P<0.0001) and DI (r= -0.95; P<0.0001) and PI with the ID... (Complete abstract click electronic access below) / Doutor
29

Ensaio de fadiga e resistência ao impacto para avaliação de conformidade de implantes mamários

Cé, Nataly Araújo January 2013 (has links)
A partir de um alerta internacional emitido pelas autoridades sanitárias francesas no ano de 2010 com respeito a altas taxas de ruptura de implantes mamários da marca Poly Implant Prothèse (PIP), a Agência de Vigilância Sanitária brasileira (ANVISA) suspendeu a importação, distribuição, comércio e uso destes implantes no país. Visando manter a qualidade destes produtos no mercado brasileiro, a partir de março de 2012 – conforme publicado pelo Instituto Nacional de Metrologia (INMETRO) – foi instituída a certificação compulsória dos implantes mamários e em seguida definidos os ensaios através dos quais os implantes mamários devem ter sua conformidade avaliada, sendo esses ensaios mecânicos e químicos. Este trabalho apresenta o desenvolvimento de equipamentos e metodologia para avaliação da conformidade de dois ensaios mecânicos em implantes mamários: ensaio de fadiga e ensaio de resistência ao impacto. Duas normas foram utilizadas para o processo de acreditação: ISO 14607 – Non - active surgical implants – Mammary implants – Particular Requirements, e ABNT NBR ISO 14607 – Implantes cirúrgicos não ativos – Implantes mamários – Requisitos particulares. Os equipamentos utilizados foram desenvolvidos e construídos ao longo do desenvolvimento deste estudo e os testes foram realizados em implantes mamários da marca PIP obtidos junto a ANVISA. A primeira etapa consistiu em organizar os documentos necessários para acreditação junto ao INMETRO e, após, ensaios os ensaios foram realizados. Ao todo trinta e cinco implantes foram ensaiados – 31 na primeira parte do trabalho e 04 na segunda – e analisados em lupa para verificação de defeitos causados pelos testes como: fraturas, cortes, alteração de forma, entre outros. Os equipamentos e metodologia desenvolvida atendem os requisitos de ambas as normas e permitem avaliação de conformidade de próteses mamárias comercializadas no país, no que diz respeito ao ensaio de fadiga e resistência ao impacto. / Due an international alert issued by French authorities in 2010 regarding high rupture rate of breast implants related to Poly Implant Prothèse (PIP), the Brazilian Health Surveillance Agency has suspended the importation, distribution, commercialization and use of these implants into Brazil. In order to maintain the quality of these products in Brazilian market, on March 2012 – according published by National Institute of Metrology – it has been decided for compulsory certification of breast implants and then defined the tests through which these products have to be submitted for its conformity assessment, being these mechanical and chemical tests. This dissertation evaluates the development and methodology for conformity assessment of two mechanical tests on breast implants: fatigue and impact resistance test. The process was based on two standards: ISO 14607 and ABNT NBR ISO – Non - active surgical implants – Mammary implants – Particular Requirements. The equipment used was developed in the laboratory during the realization of this study and the tests were performed on implants produced by PIP provided by National Sanitary Surveillance Agency. It started with the organization of the documents to be sent to National Institute of Metrology, in order to ask the accreditation and then tests were performed. Thirty five implants were tested – 31 on first part of the work and 04 on the second one – and then analyzed to detect any anomaly that could be considered a defect such as: rupture, cuts, shape alteration, etc. The equipment and methodology has met the requirements from both standards and enable conformity assessment of breast implants commercialized in Brazil, regarding to fatigue and impact resistance tests.
30

Ensaio de fadiga e resistência ao impacto para avaliação de conformidade de implantes mamários

Cé, Nataly Araújo January 2013 (has links)
A partir de um alerta internacional emitido pelas autoridades sanitárias francesas no ano de 2010 com respeito a altas taxas de ruptura de implantes mamários da marca Poly Implant Prothèse (PIP), a Agência de Vigilância Sanitária brasileira (ANVISA) suspendeu a importação, distribuição, comércio e uso destes implantes no país. Visando manter a qualidade destes produtos no mercado brasileiro, a partir de março de 2012 – conforme publicado pelo Instituto Nacional de Metrologia (INMETRO) – foi instituída a certificação compulsória dos implantes mamários e em seguida definidos os ensaios através dos quais os implantes mamários devem ter sua conformidade avaliada, sendo esses ensaios mecânicos e químicos. Este trabalho apresenta o desenvolvimento de equipamentos e metodologia para avaliação da conformidade de dois ensaios mecânicos em implantes mamários: ensaio de fadiga e ensaio de resistência ao impacto. Duas normas foram utilizadas para o processo de acreditação: ISO 14607 – Non - active surgical implants – Mammary implants – Particular Requirements, e ABNT NBR ISO 14607 – Implantes cirúrgicos não ativos – Implantes mamários – Requisitos particulares. Os equipamentos utilizados foram desenvolvidos e construídos ao longo do desenvolvimento deste estudo e os testes foram realizados em implantes mamários da marca PIP obtidos junto a ANVISA. A primeira etapa consistiu em organizar os documentos necessários para acreditação junto ao INMETRO e, após, ensaios os ensaios foram realizados. Ao todo trinta e cinco implantes foram ensaiados – 31 na primeira parte do trabalho e 04 na segunda – e analisados em lupa para verificação de defeitos causados pelos testes como: fraturas, cortes, alteração de forma, entre outros. Os equipamentos e metodologia desenvolvida atendem os requisitos de ambas as normas e permitem avaliação de conformidade de próteses mamárias comercializadas no país, no que diz respeito ao ensaio de fadiga e resistência ao impacto. / Due an international alert issued by French authorities in 2010 regarding high rupture rate of breast implants related to Poly Implant Prothèse (PIP), the Brazilian Health Surveillance Agency has suspended the importation, distribution, commercialization and use of these implants into Brazil. In order to maintain the quality of these products in Brazilian market, on March 2012 – according published by National Institute of Metrology – it has been decided for compulsory certification of breast implants and then defined the tests through which these products have to be submitted for its conformity assessment, being these mechanical and chemical tests. This dissertation evaluates the development and methodology for conformity assessment of two mechanical tests on breast implants: fatigue and impact resistance test. The process was based on two standards: ISO 14607 and ABNT NBR ISO – Non - active surgical implants – Mammary implants – Particular Requirements. The equipment used was developed in the laboratory during the realization of this study and the tests were performed on implants produced by PIP provided by National Sanitary Surveillance Agency. It started with the organization of the documents to be sent to National Institute of Metrology, in order to ask the accreditation and then tests were performed. Thirty five implants were tested – 31 on first part of the work and 04 on the second one – and then analyzed to detect any anomaly that could be considered a defect such as: rupture, cuts, shape alteration, etc. The equipment and methodology has met the requirements from both standards and enable conformity assessment of breast implants commercialized in Brazil, regarding to fatigue and impact resistance tests.

Page generated in 0.072 seconds