• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 24
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 126
  • 45
  • 23
  • 22
  • 18
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

AVALIAÇÃO DE PROPRIEDADES DE UNIÃO DE ADESIVOS UNIVERSAIS AO CANAL RADICULAR PREPARADO COM DIFERENTES INSTRUMENTOS ROTATÓRIOS / Evaluation of bonding properties of universal adhesives to root canal prepared with different rotary instruments

Bakaus, Thaís Emanuelle 16 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:01Z (GMT). No. of bitstreams: 1 Thais Bakaus.pdf: 1611331 bytes, checksum: 4d80c0ed64cbca5d883bbdad39b16c0d (MD5) Previous issue date: 2016-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this study was to evaluate the influence of a rotating device used to prepare the root canal in the adhesion of glass fiber posts and evaluate different bonding strategies using universal adhesive systems. One hundred human premolars were used, which had their crowns removed and their roots endodontically treated. Initially, the roots were divided into four groups, according to a combination of the factors: a rotating device used to prepare the root canal - carbide bur (CB) and diamond bur (DB) and cementation system (universal adhesive system associated with its respective resin cement - Single Bond Universal / RelyX ARC (SB) and Prime&Bond elect / Enforce (PB). They were then divided into subgroups according to the bonding strategy: Self-etch (SE) or Etch-and-rise (E&R). Eight teeth per group were evaluated in bond strength (BS) by the push-out test and 4 in nanoleakage teeth (NL) by scanning electron microscopy (SEM), and the roots for these tests were transversely sectioned in 6 slices. The data of BS and NI for each cementation system were subjected to 2-way ANOVA and Tukey (α = 0.05). For BS, only the major factors were significant (p <0.05), and for both cementation systems, the highest BS values were observed for the preparation with DB compared to the CB and SE adhesion strategy compared with E&R. Likewise, the interaction was not significant for NL (p> 0.05). For the cementation system PB, the lowest values were observed for groups using DB compared to the CB and SE adhesion strategy compared to E&R. For the SB cementation system, only the rotating device main factor was significant (p = 0.01), whereas the DB resulted in lower average nanoleakage compared to the CB. It can be concluded that to improve the adhesion of glass fiber posts to root canal, diamond bur should be used to prepare the root canal; and, in general, universal adhesive systems must be used in self-etch mode to obtain satisfactory results on intracanal adhesion. / Avaliou-se a influência do instrumento rotatório utilizado para preparo do conduto radicular na adesão de pinos de fibra de vidro e diferentes estratégias de adesão utilizando sistemas adesivos universais. Foram utilizados 100 pré-molares inferiores humanos, os quais tiveram suas coroas removidas e suas raízes tratadas endodonticamente. Inicialmente, as raízes foram divididas em quatro grupos, de acordo com a combinação dos seguintes fatores: instrumento rotatório utilizado para preparo do conduto radicular - broca carbide (BC) e ponta diamantada (PD) e sistema de cimentação (sistema adesivo universal associado com seu respectivo cimento resinoso) - Single Bond Universal/RelyX ARC (SB) e Prime&Bond elect/Enforce (PB). Foram divididos então em subgrupos de acordo com a estratégia de adesão: Self-etch (SE) ou Etch-and-rinse (E&R). Oito dentes por grupo foram avaliados em resistência de união (RU) pelo teste de push-out e 4 dentes em nanoinfiltração (NI) por microscopia eletrônica de varredura (MEV), sendo que para esses testes as raízes foram seccionadas transversalmente em 6 fatias. Os dados de RU e NI para cada sistema de cimentação foram submetidos à ANOVA 2 fatores e Tukey (α=0,05). Para RU, apenas os fatores principais foram significativos (p < 0,05), sendo que para ambos os sistemas de cimentação maiores valores de RU foram observados para o preparo radicular com PD em comparação com a BC e para a estratégia de adesão SE comparada a E&R. Da mesma maneira, a interação não foi significativa para NI (p > 0,05). Para o sistema de cimentação PB menores valores foram observados para os grupos que utilizaram PD em comparação com a BC e para a estratégia de adesão SE em comparação com a E&R. Para o sistema de cimentação SB, apenas o fator principal instrumento rotatório foi significante (p = 0,01), sendo que a PD resultou em menores médias de nanoinfiltração em comparação com a BC. Pode-se concluir que para melhorar a adesão de pinos de fibra de vidro ao canal radicular pontas diamantadas devem ser utilizadas para o preparo do conduto radicular; e, de maneira geral, os sistemas adesivos universais devem ser utilizados na maneira self-etch para obterem resultados satisfatórios de adesão intracanal.
82

Compartimentos da matéria orgânica do solo, agregação, mecanismos de proteção e sequestro de carbono influenciados pela calagem superficial em sistema plantio direto

Briedis, Clever 14 June 2010 (has links)
Made available in DSpace on 2017-07-25T19:29:44Z (GMT). No. of bitstreams: 1 Clever Briedis.pdf: 1258130 bytes, checksum: ffdbaa47bb93b2258b4ff51d6b50f9ad (MD5) Previous issue date: 2010-06-14 / Liming is the most often practice used to neutralize soil acidity, and also promotes chemical changes that can alter the soil organic matter (SOM) pools and the mechanisms of flocculation, formation and stabilization of macro-and microaggregates. The objective of this study was to evaluate carbon sequestration, in the whole and in the aggregates samples, and the changes in the SOM pools affected by liming in a long-term no-tillage. The experiment was conducted in an Oxisol, located in Ponta Grossa, PR. The experimental design was a randomized complete block, arranged as split plot with three replications. The main plot consisted of dolomite lime applied on the soil surface at a 0 or 6 Mg ha-1 in 1993, and 0 or 3 Mg ha-1 in 2000 in plots previously with and without lime, and the treatments was assigned as: 0+0, 6+0, 0+3 and 6+3 Mg ha-1. The subplots were represented by sampling depth and consist of 0-2.5, 2.5-5, 5-10 and 10-20 cm layer. The soil samples were taken in September 2008 and the total organic carbon (TOC) was analyzed in the whole sample, in the aggregates and in the particulate organic carbon (POC) and in the fraction associated with minerals carbon (OCAM). Aggregates of 8-19 mm, in the 0-2.5 cm layer were analyzed by using scan microscope spectrometer X-ray (EDS) for elemental analysis of carbon (C) and calcium (Ca). Liming promoted accumulation of TOC mainly in the layer 0-2.5 cm. The TOC stocks at 0-20 cm were 49.9, 52.9, 52.7 and 57.5 Mg ha-1 for 0+0, 6+0, 0+3, 6 +3 treatments, respectively. Stocks in the SOM fractions were also increased with liming. The increase in POC stock was close relationship (R2 = 0.98, P = 0.011) with the C accumulated input through crop residue, which was higher in plots that were limed. A positive correlation was found between TOC and C extracted in hot water (CHW), total polysaccharides (TP) and labile (LP). Correlations also showed that TOC had a closer relationship with POC than with OCAM, suggesting a greater influence on the labile fraction of TOC increase with liming. In aggregate, the effect of liming in TOC accumulation was mainly in 0-2.5 cm depth. The treatments with liming showed high mean weight diameter (MWD), which provided a large stock of TOC in the 8-19 mm aggregate size. A higest proportion of large aggregates with liming was closely correlated with the TOC content of whole sample. The highest liming dosis resulted in both COP and in OCAM, in the largest class of aggregates. The proportion of POC average of the treatments in relation to OCAM, this class of aggregates, has decreased in depth, and were 18, 13, 10 and 8% at depths of 0-2.5, 2.5-5, 50-10 and 10-20, respectively. Elemental analysis of C and Ca showed a positive correlation of those elements contained in a section of clay from the center of 8-19 mm aggregates. The results suggest that application of lime in soil with clay fraction dominated by kaolinite, brings benefits to structuring and promotes an increase of C in the whole sample and in aggregates. / A calagem é a prática mais utilizada para neutralizar a acidez do solo, porém promove também modificações químicas capazes de alterar os compartimentos da matéria orgânica do solo (MOS) e mecanismos de floculação, formação e estabilização de macro e microagregados. O objetivo desse trabalho foi avaliar o seqüestro de carbono, na amostra integral e nos agregados, e as alterações nos compartimentos da MOS afetados por calagem superficial em sistema plantio direto de longa duração. O experimento foi conduzido em um Latossolo Vermelho textura média, no município de Ponta Grossa, PR. O delineamento experimental foi o de blocos completos ao acaso em parcelas subdivididas, com três repetições. As parcelas consistiram da aplicação de calcário dolomítico na superfície do solo na dose de 0 ou 6 Mg ha-1 em 1993, e dose de 0 ou 3 Mg ha-1 em 2000 nas parcelas previamente com e sem calcário, compondo os tratamentos: 0+0; 6+0; 0+3 e 6+3 Mg ha-1. As subparcelas foram constituídas pelas profundidades de coleta, sendo realizadas em 0-2,5, 2,5-5, 5-10 e 10-20 cm de profundidade. As coletas de solo foram realizadas em setembro de 2008 e analisados os conteúdos de carbono orgânico total (COT) na amostra total, nos agregados e nas frações particulada (COP) e associada aos minerais (COAM) da matéria orgânica do solo (MOS). Agregados de 8-19 mm, da camada 0-2,5 cm, foram analisados através do uso de espectrômetro de dispersão de raios X (EDS) para a análise elementar de carbono (C) e cálcio (Ca). A calagem promoveu acúmulo de COT, principalmente na camada 0-2,5 cm. Os estoques de COT na camada de 0-20 cm foram 49,9, 52,9, 52,7 e 57,5 Mg ha-1 para os tratamentos 0+0, 6+0, 0+3 e 6+3, respectivamente. Os estoques nas frações da MOS também foram aumentados com a calagem. O aumento no estoque de COP foi estreitamente relacionado (R2=0,98; P=0,011) com a adição acumulada de C via resíduo cultural, a qual foi mais elevada nas parcelas que receberam calagem. Houve correlação positiva entre COT e carbono em água quente (CAQ), polissacarídeos totais (PT) e lábeis (PL). Correlações também demonstraram que o COT teve relação mais estreita com o COP do que com COAM, sugerindo maior influência da fração lábil no aumento de COT com a calagem. Nos agregados, a calagem proporcionou acúmulo de COT principalmente na profundidade de 0-2,5 cm. A calagem aumentou o diâmetro médio ponderado (DMP), proporcionando grande estoque de COT na classe de agregado 8-19 mm. A elevada proporção de agregados grandes nos tratamentos com calagem foi estreitamente correlacionado com o conteúdo de COT da amostra integral. A maior dose de calcário proporcionou aumento no estoque de COT tanto em COP quanto em COAM, visto principalmente na maior classe de agregados. A proporção de COP em relação ao COAM, na média dos tratamentos, nessa classe de agregados, diminuiu em profundidade, ficando em torno de 18, 13, 10 e 8 % nas profundidades de 0-2,5, 2,5-5, 5-10 e 10-20, respectivamente. Análise elementar de C e Ca demonstraram correlação positiva dos dois elementos contidos em uma secção da fração argila do centro de agregados de 8-19 mm. A aplicação de calcário, em solo dominado na fração argila por caulinita, traz benefícios à estruturação e promove aumento de C na amostra integral e nos agregados.
83

Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromium

Luciana Mara Negrão Alves 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental &ldquo;SR&rdquo; . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150&mu;m) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100&mu;m) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
84

Caracterização físico-química e analítica de fibras capilares e ingredientes cosméticos para proteção / Analytical and physical chemistry characterization of hair fibers and cosmetic ingredients for protection

Lima, Cibele Rosana Ribeiro de Castro 12 April 2016 (has links)
Com o aumento dos tratamentos químicos e/ou físicos nos cabelos aos quais são realizados mediante o uso de dispositivos térmicos, há uma maior preocupação a respeito dos danos causados aos cabelos por estes tipos de tratamentos. O conhecimento dos efeitos, benefícios e/ou malefícios, de ingredientes cosméticos em cabelos torna-se necessário, pois facilita a busca por produtos baseada no tipo de cabelo. O principal objetivo do trabalho foi a caracterização físico-química, analítica e térmica de mechas de cabelo de diferentes etnias (caucasiano, oriental e afro-étnico virgem e brasileiro virgem e descolorido) antes e após o uso de ingredientes cosméticos seguido de um tratamento térmico (utilizando piastra) e intercalando com lavagens. O estudo das amostras de cabelo e de uma amostra de queratina animal envolveu a utilização das técnicas de TG/DTG, DSC, análise elementar, FTIR, MEV e técnicas de avaliação de eficácia, como tensão/deformação, penteabilidade e quebra por escovação. A partir da TG/DTG, foi possível avaliar as etapas de decomposição térmica das amostras de cabelo virgem e de queratina animal e estas apresentaram um comportamento térmico semelhante entre si. O estudo cinético não isotérmico por TG mostrou que, dos diferentes tipos de amostras de cabelo virgem, o afro-étnico apresentou menor estabilidade térmica e o oriental foi o mais estável termicamente. Os resultados de DSC corroboraram os obtidos por TG, demonstrando que a amostra de cabelo afro-étnico apresentou temperatura de desnaturação térmica das cadeias de &#945;-queratina menor (TD = 223&#176;C) do que as amostras dos outros tipos de cabelo (TD = 236&#176;C). As mechas de cabelo virgem e clareadas foram tratadas com formulações cosméticas contendo silicones e avaliadas quanto a eficiência destes na proteção térmica dos cabelos. Algumas delas mostraram eficiência na proteção térmica das cadeias de &#945;-queratina, diminuindo o seu grau de desnaturação. Foi possível observar que a associação do calor da piastra com as lavagens sucessivas causou danos tanto à cutícula (conforme resultados de FTIR e MEV), como também, ao córtex dos cabelos (conforme resultados de DSC). Em alguns casos, os danos causados foram tão graves que as camadas mais superficiais da cutícula sofreram descamações. O estudo mostrou, também, que a eficiência da proteção térmica nos cabelos depende do tipo da formulação cosmética em que estes protetores estão incorporados e do estado em que os cabelos se encontram. A DSC permitiu a avaliação da modificação termicamente induzida das cadeias de &#945;-queratina e sua posterior desnaturação. O estudo envolvendo a associação das diferentes técnicas apresentou-se viável na avaliação tanto dos danos causados aos cabelos quanto na eficiência dos ingredientes cosméticos na proteção térmica dos mesmos. / With the increase of chemical and/or physical hair treatments, there is an increased concern about the damage caused by the continued use of thermal equipment. This is due to products identified as \"progressive brush\", widely used by individuals of various types of hair, in order to straighten them that are employed with the mandatory use of piastra. Thus, knowledge about the effects, benefits and/or detriments, of cosmetic ingredients in hair of different ethnic groups becomes necessary because it facilitates the search for products based on the type of hair. The main objective this work was the physicochemical, analytical and thermal characterization of hair samples of different ethnic groups (caucasian, oriental, african-ethnic and brazilian type II) before and after the use of cosmetic ingredients followed by heat treatment, using piastra, interleaved by washes. For such purpose, it was used the TG/DTG, DSC, EA, FTIR, SEM and techniques for evaluation of effectiveness as stress/strain and combing. By TG/DTG, it was possible to evaluate the thermal decomposition events of hair and animal keratin samples and these showed a similar thermal behavior between them. The TG-non isothermal kinetic study showed that, from the different types of virgin hair samples, the african-ethnic hair samples had the lowest thermal stability and oriental hair samples were more thermally stable. The DSC results confirm the results obtained by TG, demonstrating that african-ethnic hair samples had thermal denaturation temperature of &#945;-keratin chains (TD = 223&#176;C) lower than the samples from other types of hair (TD = 236&#176;C). The virgin and bleached hair tresses were treated with cosmetic formulations containing silicones and evaluated the efficiency of the thermal protection of the hair. Some of the formulations tested have shown to be efficient as to its protective effect on the degradation of the &#945;-keratin chains, decreasing the degree of denaturation. It was observed that the combination of the heat of piastra with successive washes caused damage to the hair cuticle (according to the IR and SEM results) as well as the cortex of hair (according DSC results). In some cases, the damage was so severe that the most superficial layers of the cuticle suffered flaking. The study also showed that the efficiency of the thermal protection in the hair depends on the type of cosmetic formulation that these protectors are incorporated and the condition of the hair. DSC technique allowed monitoring of the thermally induced modification of the &#945;-keratin chains and subsequent denaturation. The study of the combination of all the techniques, as presented, is feasible in measuring damage to hair and the efficiency of cosmetic ingredients in protecting them.
85

Estudo estrutural de compósitos de matriz polimérica reforçados com fibras de juta

Almeida, Nuno Miguel Bastos de January 2012 (has links)
Tese de Mestrado Integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2012
86

Análise de uma nova ponta ultrassônica para agitação do irrigante em preparos retrógrados / Assessment of a new ultrasonic tip for irrigant agitation in root-end cavity preparations

Valencia, Yahir Muñoz 13 March 2019 (has links)
O objetivo desde estudo foi avaliar a eficiência de remoção de smear layer e a influência da resistência de união de cimentos de silicato de cálcio de um novo inserto ultrassônico para agitação do irrigante em preparos retrógrados. Metodologia Foram selecionados 112 caninos unirradiculados, que foram formatados e obturados de forma convencional com a subsequente ressecção apical. Seguidamente, foram conformados 4 grupos de avaliação, ultra-som/solução salina; convencional/solução salina; ultra-som/EDTA17% e convencional/EDTA17%. Para analisar a remoção do smear layer, 72 espécimes foram divididos em 4 grupos (n=18), e retroprepararados utilizando uma ponta ultrassônica. Os espécimes foram clivados, obtendo-se dois segmentos iguais (mesial e distal). Os segmentos retrocavitários foram observados através da microscopia eletrônica de varredura (MEV), a partir de três regiões representativas a 250x, obtendo-se imagens correspondentes à pré-irrigação. Posteriormente, foram executados os protocolos de irrigação e novamente obtidas imagens representativas da pós-irrigação. Para o teste de push-out, 40 dentes alocados em 4 grupos (n=10) foram empregados, conforme os diferentes protocolos de irrigação previamente mencionados. Os espécimes foram retrobturados e a obtenção dos corpos-de-prova realizada a partir de um novo seccionamento apical de 2mm±0.1 de cada espécime. A resistência de união foi determinada por meio de uma máquina de ensaios mecânicos e o tipo de falha foi determinado por meio de MEV. Os dados foram comparados por meio dos testes de Kruskal-Wallis e Dunn para a remoção de smear layer e ANOVA e Tukey no teste de push-out. Resultados O grupo ultrassom/EDTA17% removeu significativamente uma maior quantidade do smear layer, observando-se uma maior porcentagem de túbulos dentinários abertos em comparação com os outros grupos (P < 0.05). Na resistência de união, o grupo ultrasom/ EDTA17% mostrou os maiores valores na resistência de união (6.42±0.69) seguido pelos grupos convencional/EDTA17%, ultra-som/solução salina e convencional/solução salina respectivamente (P < 0.05). O padrão de falha adesivo foi o mais predominante, enquanto que no grupo ultrassom/EDTA17% foi preponderantemente mista (8/10). Conclusões O novo inserto ultrassônico para ativação do irrigante promoveu uma maior remoção de smear layer além de favorecer maior resistência de união do material retrobturador às paredes dentinárias em preparos retrógrados, principalmente se associado ao EDTA17%. / To evaluate the smear layer removal capacity and its influence on the bond strength of a calcium silicate-based cement of a new ultrasonic tip for irrigant agitation in rootend cavity preparations. Methods: One hundred and twelve maxillary and mandibular canines were chemomechanically instrumented, root filled and the root apexes resected. Specimens were randomly distributed into 4 experimental groups: ultrasonic/saline solution; conventional/ saline solution; ultrasonic/EDTA 17% and conventional/EDTA solution 17%. The analysis of the smear layer removal employed seventy-four specimens divided into 4 groups (n=18), and the retrograde cavities were prepared using an ultrasonic tip. Next, the specimens were split longitudinally and obtained two halves (mesial and distal). Scanning electron microscopy (SEM) was used to examine and score the internal surfaces for dentinal tubule opening before and after to perform the irrigation protocols. Images were taken at three representative areas with a magnification of 250x. The push-out test employed forty specimens allocated in four groups (n=10), according to the different irrigation protocols previously described. The specimens were retrofilled, sectioned perpendicularly and obtained apical slices at 2mm±0.1 from the apex. Each disc/dentin/retrofilling material was placed in a testing machine for the bond strength measurement and the failure mode was observed by SEM. The smear layer removal data were analysed and compared using Kruskal-Wallis and Dunn. Push-out data were analysed using ANOVA and Tukey\'s test. Results The ultrasonic/EDTA 17% group removed the smear later more effectively, and showed the best tubule opening condition than the others three groups. (P < 0.05). Ultrasonic/EDTA 17% group demonstrated the highest mean bond strength values (6.42±0.69) compared with conventional/EDTA, ultrasonic/saline solution and conventional/saline solution, respectively (P < 0.05). Most failure modes were predominantly adhesive (55%), whereas in the ultrasonic/EDTA 17% group was mixed (80%). Conclusion The new ultrasonic tip for irrigant agitation showed higher percentage of smear layer removal and improved the push-out bond strength of the retrograde root filling to the root-end dentine surfaces, mainly when associated to EDTA 17%.
87

Mesure des observables de polarisation dans la photoproduction des mésons pseudoscalaires à GRAAL

Calvat, P. 08 January 1997 (has links) (PDF)
L'expérience de physique nucléaire GRAAL installée à Grenoble auprès du synchrotron européen (ESRF) produit, par rétrodiffusion Compton, un faisceau de gammas polarisés linéairement ou circulairement. <br /><br />Les caractéristiques d'un tel faisceau rendent possible l'étude des réactions de photoproduction de mésons pseudoscalaires (pion, eta, kaon) dont certains aspects théoriques sont explicités dans le cadre de cette thèse. <br /><br />Une description précise des programmes d'analyse permet de comprendre le traitement complet des informations depuis l'acquisition des données jusqu'à la présentation des premiers résultats expérimentaux sur l'asymétrie Sigma du faisceau pour les réactions gamma + p -> p + X (X = pi, eta) dans le domaine d'énergie situé entre 700 et 1100 MeV. <br /><br />Des méthodes d'extraction des observables de polarisation de la réaction gamma + p -> K+ + Lambda ont été mises au point à partir de la simulation Monte Carlo. La reproduction précise des trois observables de simple polarisation (P, Sigma, T) et des quatre observables de double polarisation faisceau-recul (Ox, Oz, Cx, Cz), pour un ensemble de données correspondant à 100000 réactions gamma + p -> K+ + Lambda, montre que ces quantités peuvent être mesurées dans l'expérience GRAAL.
88

Biological effects of high energy radiation and ultra high dose rates

Zackrisson, Björn January 1991 (has links)
Recently a powerful electron accelerator, 50 MeV race-track microtron, has been taken into clinical use. This gives the opportunity to treat patients with higher x-ray and electron energies than before. Furthermore, treatments can be performed were the entire fractional dose can be delivered in parts of a second. The relative biological effectiveness (RBE) of high energy photons (up to 50 MV) was studied in vitro and in vivo. Oxygen enhancement ratio (OER) of 50 MV photons and RBE of 50 MeV electrons were investigated in vitro. Single-fraction experiments, in vitro, using V-79 Chinese hamster fibroblasts showed an RBE for 50 MV x-rays of approximately 1.1 at surviving fraction 0.01, with reference to the response to 4 MV x- rays. No significant difference in OER could be demonstrated. Fractionation experiments were carried out to establish the RBE at the clinically relevant dose level, 2 Gy. The RBE calculated for the 2 Gy/fraction experiments was 1.17. The RBEs for 20 MV x-rays and 50 MeV electrons were equal to one. In order to investigate the validity of these results, the jejunal crypt microcolony assay in mice was used to determine the RBE of 50 MV x-rays. The RBE for 50 MV x-rays in this case was estimated to be 1.06 at crypt surviving fraction 0.1. Photonuclear processes are proposed as one possible explanation to the higher RBE for 50 MV x-rays. Several studies of biological response to ionizing radiation of high absorbed dose rates have been performed, often with conflicting results. With the aim of investigating whether a difference in effect between irradiation at high dose rates and at conventional dose rates could be verified, pulsed 50 MeV electrons from a clinical accelerator were used for experiments with ultra high dose rates (mean dose rate: 3.8 x 10^ Gy/s) in comparison to conventional (mean dose rate: 9.6 x 10"^ Gy/s). V-79 cells were irradiated in vitro under both oxic and anoxic conditions. No significant difference in relative biological effectiveness (RBE) or oxygen enhancement ratio (OER) was observed for ultra high dose rates compared to conventional dose rates. A central issue in clinical radiobiological research is the prediction of responses to different radiation qualities. The choice of cell survival and dose response model greatly influences the results. In this context the relationship between theory and model is emphasized. Generally, the interpretations of experimental data are dependent on the model. Cell survival models are systematized with respect to their relations to radiobiological theories of cell kill. The growing knowledge of biological, physical, and chemical mechanisms is reflected in the formulation of new models. This study shows that recent modelling has been more oriented towards the stochastic fluctuations connected to radiation energy deposition. This implies that the traditional cell survival models ought to be complemented by models of stochastic energy deposition processes at the intracellular level. / <p>S. 1-44: sammanfattning, s. 47-130: 5 uppsatser</p> / digitalisering@umu
89

Beyond the adiabatic model for the elastic scattering of composite nuclei

Summers, Neil Christopher January 2001 (has links)
No description available.
90

A High-Energy, Ultrashort-Pulse X-Ray System for the Dynamic Study of Heavy, Dense Materials

Gibson, D J January 2004 (has links)
Thesis (Ph.D.); Submitted to Univ. of California, Davis, CA (US); 17 Sep 2004. / Published through the Information Bridge: DOE Scientific and Technical Information. "UCRL-TH-207378" Gibson, D J. 09/17/2004. Report is also available in paper and microfiche from NTIS.

Page generated in 0.0307 seconds