• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 84
  • 68
  • 12
  • 6
  • 5
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 214
  • 74
  • 39
  • 30
  • 30
  • 25
  • 21
  • 19
  • 18
  • 16
  • 15
  • 14
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Estudo radiográfico das medidas da patela e do sulco troclear em cães toys hígidos e portadores de luxação patelar medial graus II e III / Radiographic study of the measures of the patella and the trochlear groove in toys healthy dogs and medial patellar luxation grades II and III carriers

OLIVEIRA, Graziela Kopinits de 22 January 2016 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2016-08-03T13:51:22Z No. of bitstreams: 1 Graziela Kopinits de Oliveira.pdf: 764547 bytes, checksum: 2a8e9f311235bc2f8df978f6a19f926d (MD5) / Made available in DSpace on 2016-08-03T13:51:22Z (GMT). No. of bitstreams: 1 Graziela Kopinits de Oliveira.pdf: 764547 bytes, checksum: 2a8e9f311235bc2f8df978f6a19f926d (MD5) Previous issue date: 2016-01-22 / Medial patellar dislocation is a common condition in small dogs and should be diagnosed and treated as early as possible in order to prevent further deformities and secondary osteoarthritis. The objective of this article was to study the measures and the anatomic relationships of the trochlear groove and patella in radiographic examinations of healthy dogs predisposed to medial patellar dislocation breeds, analyzing and comparing with the trochlear groove and patellar of patients with such disease. 40 knees of predisposed pure breeds dogs were used which were divided into two groups: group 1 (G1) consisting of 18 knees that do not show patellar dislocation and group 2 (G2) consisting of 22 knees showing patella in the medial grade II or III. Depth and width trochlear groove, height and thickness of the patella, a percentage of the patella in the groove, groove angle troclear were measured and calculated the ratios of patellar width and trochlear groove and depth of the trochlear groove and thickness of the patella. All parameters studied showed statistically significant differences, in comparison between healthy and affected dogs, compared to being evaluated by Student's t test. Through evaluation and measurements on radiographs G1 dogs, it were developed predictor formulas of broadening (Lsd = Lpp/0,89 – Lsp) and deepening (Psd = 0,65Ep –Psp) required the trochlear groove to perform trochleoplasty block. / Luxação medial da patela é uma afecção comum em cães de pequeno porte, devendo ser diagnosticada e tratada o mais cedo possível com objetivo de evitar maiores deformações e alterações articulares secundárias. O objetivo deste trabalho foi estudar as medidas e as relações anatômicas do sulco troclear e da patela através de exames radiográficos de cães sadios de raças predispostas à luxação patelar medial, analisando e comparando com o sulco troclear e patela de pacientes portadores desta enfermidade. Foram utilizados 40 joelhos de cães de raças predispostas que foram divididos em dois grupos, sendo o grupo 1 (G1) composto de 18 joelhos que não apresentavam luxação de patela e o grupo 2 (G2) composto de 22 joelhos que apresentem luxação de patela medial em graus II ou III. Foram realizadas mensurações de profundidade e largura do sulco troclear, altura e espessura da patela, percentual da patela dentro do sulco, ângulo do sulco troclear, sendo calculadas as razões entre largura patelar e do sulco troclear e profundidade do sulco troclear e espessura da patela. Todos os parâmetros estudados demonstraram diferença estatística significativa, na comparação entre cães sadios e portadores da afecção, ao serem avaliadas pelo teste t de Student. Através dessas medições realizadas nas radiografias dos cães do G1 foram desenvolvidas fórmulas preditivas do alargamento (Lsd = Lpp/0,89 – Lsp) e aprofundamento (Psd = 0,65Ep –Psp) do sulco troclear, para realização de trocleoplastia em bloco.
122

Técnica de interligação extracapsular femoro-fabelo-tibial na ruptura do ligamento cruzado cranial em cães – achados clínicos e radiográficos / Extracapsular femur-fabelo-tibial interconnection technique used in dogs with cranial cruciate ligament rupture – clinical and radiographic findings

BARAÚNA JÚNIOR, Durval 16 February 2006 (has links)
Submitted by (edna.saturno@ufrpe.br) on 2016-08-15T15:51:58Z No. of bitstreams: 1 Durval Barauna Junior.pdf: 734474 bytes, checksum: 741df0e4a7b2278f3858f4d6f5cb23db (MD5) / Made available in DSpace on 2016-08-15T15:51:58Z (GMT). No. of bitstreams: 1 Durval Barauna Junior.pdf: 734474 bytes, checksum: 741df0e4a7b2278f3858f4d6f5cb23db (MD5) Previous issue date: 2006-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Cranial cruciate ligament rupture (CCLR) is a common disease in dogs that cause joint instability resulting in lameness and rapid development of degenerative joint disease (DJD). The aim of this work was evaluate the results of a new technique of restoration of joint femur-fabelo-tibial stability for the treatment of spontaneous CCLR in dogs, using for this purpose clinical and radiographic features. Sixteen joint of fifteen dogs were operated, six male and nine female, with weight between 2.3 to 53.0 kg (median 8.4 kg) and age between 1 year and 10 months to 11years (mean 6.1± 2.8 years), miscellaneous breed and that the interval between the suspect of lesion by the owners and the surgical procedures varied between 3 to 365 days (mean 123 ±131.5 days), were submitted to the surgical correction though the extracapsular femur-fabelo-tibial interconnection technique. The tibial compression radiographs and the distal displacement of the popliteal sesamóide were 100 per cent efficient and sensitive to the diagnostic of CCLR. In anyone of the sixteen operated joint were observed difficulty or intra-operative complication. In 3 dogs were observed discreet instability (until 2mm) in the cranial drawer test and the tibial compression test, until 180 days; however these dogs didn’t show any damage in the functional evaluation in this period. In another three operated joints a discreet degree of cranial drawer remains until the 30º day, disappearing completely at 90 days. After 30 days of the surgery all the animals showed a improvement (P≤0.05) in the evaluated parameters, with progressive improvement until the 90 days after the surgical. There was no more change statistically significant, although observed clinical improvement until 180 days, when all the animals showed complete functional recovery. The increase (90 and 180 days) in the thigh perimeter weren’t statistically significant. Among 20 joints evaluated (operated or non operated) radiographically between 0 and 180 day, the evolution of degenerative changes was seen in 90 per cent of joints. It was possible conclude that the extracapsular femur-fabelo-tibial interconnection technique evaluated in this experiment is efficient in the immediate stabilization of joint with CCLR, offering functional recovery for reduce the cranial displacement and internal rotation of the tibia, however it not arrest the osteoarthritis progression. Secondarily it can be conclude that: the nylon strands despite its elasticity and plastic deformation can produce a discreet clinical instability, it continue been a good option for joint stabilization because of its low cost, feasibility of sterilization, no production of fistulous tracts and disposability of different diameters with variable resistance adequate for the animal size. Thick strands of difficult management can be arrest through by crimp clamp system with relative facility. Another important conclusion is that like the radiographic tibial compression test, the orthopedic evaluation with tibial compression test and cranial drawer test is 100 per cent efficient in the diagnosis of CCLR, in dogs. / A ruptura do ligamento cruzado cranial (RLCC) é uma afecção comum em cães, geradora de instabilidade do joelho, resultando em claudicação e rápido desenvolvimento de doença articular degenerativa. O objetivo deste trabalho foi avaliar os resultados de uma nova técnica de reconstituição da estabilidade da articulação femoro-tíbio-patelar, como forma de tratamento da RLCC espontânea em cães, utilizando para isto avaliações clínicas e radiográficas. Foram operados 16 joelhos de 15 cães afetados, sendo seis machos e nove fêmeas, com peso variando entre 2.3 a 53.0 kg (mediana 8.4 kg), idades entre um ano e 10 meses a 11 anos (média 6.1 ± 2.8 anos), de raças variadas e onde o intervalo entre a suspeita da lesão por parte dos proprietários e os procedimentos cirúrgicos variaram entre três a 365 dias, (média 123 ± 131.5 dias), que foram submetidos à correção cirúrgica através da técnica de interligação extracapsular femoro-fabelo-tibial. O exame radiográfico sob teste de compressão tibial e a avaliação do deslocamento distal do sesamóide do poplíteo foram 100% eficientes e sensíveis, para o diagnóstico da RLCC. Em nenhum dos 16 joelhos operados foram observadas dificuldades ou complicações trans-operatórias. Em três cães foi observada instabilidade discreta (até 2mm) no movimento de gaveta cranial (MGC) e no teste de compressão tibial, até 180 dias; entretanto estes cães não apresentaram prejuízos na avaliação funcional neste mesmo período. Em outros três joelhos operados um grau discreto de MGC permaneceu até o trigésimo dia desaparecendo completamente no retorno aos 90 dias. Aos 30 dias após a cirurgia todos os animais apresentavam uma melhora (P≤ 0.05) nos parâmetros avaliados, com progressão da melhora até os 90 dias após a cirurgia, a partir daí não houve mais modificação estatisticamente significante, embora tenha sido observada melhora clínica até os 180 dias, quando todos os animais apresentaram plena recuperação funcional. Os incrementos (90 e 180 dias) no perímetro da coxa não foram estatisticamente significantes. Dos 20 joelhos avaliados (operados e não operados) radiograficamente nos dias zero e 180, a evolução das alterações degenerativas foi observada em 90% destes. Foi possível concluir que a técnica de interligação extracapsular femoro-fabelo-tibial avaliada neste experimento é eficiente na estabilização imediata da articulação com RLCC, oferecendo recuperação funcional ao reduzir o deslocamento cranial e a rotação interna da tíbia, porém que não impede a progressão da osteoartrite. Secundariamente pode-se concluir que: o fio de náilon, apesar da sua elasticidade e deformação plástica poder produzir uma discreta instabilidade clinica, este continua sendo uma boa opção para estabilização articular em virtude do seu baixo custo, facilidade de esterilização, não produzir tratos fistulosos, possuir diferentes diâmetros com resistências variadas adequadas ao tamanho do animal. Fios grossos de difícil manuseio podem ser presos através de grampos tubulares com relativa facilidade. Outra conclusão importante é que assim como o exame radiográfico sob o teste de compressão tibial, o exame ortopédico com testes de compressão tibial e de movimento de gaveta cranial é 100% eficiente no diagnóstico da RLCC, em cães.
123

Avaliação eletromiografica de musculos da mastigação em pacientes portadores de maloclusão tratados com ortopedia funcional dos maxilares / Electromyographic assessmet of mastication muscles form patiets with malocclusions attended by functional maxilary orthopedics

Sakai, Eduardo 14 August 2018 (has links)
Orientador: Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T20:04:47Z (GMT). No. of bitstreams: 1 Sakai_Eduardo_D.pdf: 1729453 bytes, checksum: 9d79d689e7942338b5e9324dedb601c5 (MD5) Previous issue date: 2006 / Resumo: Selecionou-se 164 voluntários, e a coleta dos sinais eletromiográficos realizou-se bilateralmente dos músculos temporal porção anterior, masseter e supra-hióideos, em 19 voluntários que atenderam aos critérios de inclusão à amostra. Os equipamentos utilizados foram o módulo condicionador de sinais da Lynx Eletronics Ltda. com oito canais, modelo EMG 1000; Placa Conversora A/D, modelo CAD 12/32 da Lynx Eletronics Ltda. 16 bites; Software AqDAnalysis 4,18 da Lynx Eletronics Ltda.; Software Lynx BioInspector 1,8r; eletrodos de superfície passivos (Ag/AgCl) da Noraxon Dual Electrodes (USA); eletrodos de referência descartável com Gel auto adesivo da Kendall Meditrace (Ag/AgCl) - Canadá (eletrodo terra); Computador Pentium IV Intel 650MHz, com HD de 80 GB, memória RAM de 512 MB. A calibração da freqüência foi de 2000 Hz, com 2048 amostras por canal e tempo de 1,024 segundo, e a regulagem dos filtros passam - alta (20 Hz) e passa - baixa (1000 Hz). Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital. / Abstract: Growth, development and correct Stomatognatic System functioning can interact by a positive way or not; it could be positive if happened by natural way (without professional action) or by any kind of preventive or corrective treatment. The Functional Maxillary Orthopedics under Neuro Oclusal Rehabilitation point of view, used resources that could give conditions to the System to gain physiological normality by itself using stimulus and not inducing it to treatments objectives that don¿t should a good performance for functions, especially mastication using both sides, under physiologic way, maintaining the integrity of all system. A hundred sixty four volunteers were selected, and the electromyographic signals registration was done in 19 volunteers witch obey to criteria inclusion. The equipment used was a signal conditioner ( Lynx Eletronics Ltda ,Brazil).,with 8 channels, model EMG 1000; Converser plate A/D,model CAD 12/32 ( Lynx Eletronics Ltda,Brasil) with 16 bites; Software AqDAnalysis 4,18 ( Lynx Eletronics Ltda.,Brazil); Software Lynx BioInspector 1,8r; active surface electrodes (Ag/AgCl) (Noraxon Dual Electrodes, USA), dischargeable reference electrodes with adhesive gel ( Kendall Meditrace (Ag/AgCl) , Canada) ;Computer Pentium IV Intel 650MHz, HD 80 GB, RAM 512 MB. The frequency calibration was 2000 Hz, with 2048 sample by channel and 1,024 second, low-pass filter in 20 Hz and high-pass in 100 Hz. Note: The complete abstract is available with the full electronic document. / Doutorado / Anatomia / Doutor em Biologia Buco-Dental
124

Relação interarcos em pacientes com FLPUC submetidos à queiloplastia neonatal versus queiloplastia em fase convencional com e sem ortopedia infantil / Dental arch relationships in patients with unilateral cleft lip and palate (UCLP) undergoing early lip repair versus late repair with and without infant orthopedics

Thalita Varela Galassi 05 August 2016 (has links)
Objetivo: comparar a relação interarcos de 112 indivíduos com FLPUC submetidos a queiloplastia neonatal versus em fase convencional, com e sem ortopedia infantil, aplicando-se o índice oclusal de Goslon/5 anos em fotografias intrabucais, obtidas entre 6 e 12 anos de idade. Desenho: estudo retrospectivo de coorte. Local: dois centros de reabilitação do Brasil. Participantes: três grupos tratados com distintos protocolos: grupo I: queiloplastia neonatal (1 a 15 dias) + OI (ortopedia Infantil); grupo II: queiloplastia (3 a 12 meses) + OI; grupo III: queiloplastia (3 a 6 meses), sem OI. Intervenções: o grupo I (n=35) e grupo III (n=58) foram operados pelo mesmo cirurgião, enquanto que o grupo II (n=19) por 4 cirurgiões. Método: para comparação entre os grupos foi utilizado o teste qui-quadrado e para a comparação dos índices oclusais médio intergrupos foi aplicado o ANOVA, Kruskal Wallis (p<0,05). Resultados: a concordância interexaminadores (acima 0,70) e intra (acima de 0,60) foi dada pela estatística kappa. O grupo I apresentou maior percentual de índice 5. O grupo II apresentou o maior percentual de índice 1 e o grupo III apresentou o menor percentual de índice 5 (p=0,029). As estatísticas com os índices agrupados em 1+2 e 4+5 não demonstraram diferenças entre os 3 grupos (p=0,142). O índice oclusal médio em cada grupo apresentou diferenças significativas entre os grupos I (4,0) e III (3,0) (p=0,022). Conclusão: os resultados demonstraram que em relação ao crescimento maxilomandibular, a queiloplastia em fase neonatal com OI (grupo I) apresentou-se menos favorável quando comparada aos outros dois grupos operados a partir dos três meses. O grupo II, operados mais tardiamente de lábio e palato com OI apresentou crescimento favorável enquanto que o grupo III sem OI presentou a menor quantidade de casos com prognóstico ortodôntico-cirúrgico. Considerando a variabilidade e limitações da amostra sugerimos mais trabalhos que envolvam centros que utilizam os protocolos com e sem ortopedia infantil, de preferência de forma prospectiva e randomizada. / Objective: to compare the outcomes of early versus conventional cheiloplasty with and without infant orthopedics (IO) by assessment of dental arch relationships in individuals with non-syndromic complete UCLP, analyzed by the occlusal index for intraoral photographs rating. Design: retrospective cohort study. Setting: two cleft palate centers from Brazil. Participants: three groups treated by different protocols, as follows; Group I: early cheiloplasty (1 to 15 days) + infant IO; Group II: cheiloplasty (3 to 12 months) + IO; Group III: cheiloplasty (3 to 6 months) without IO and palatoplasty (12 to 18 months). Interventions: Individuals in Group I (n=35) and Group III (n=58) were operated by a single surgeon each, while individuals in group II (n=19) were operated by 4 surgeons. The 112 intraoral photographs of individuals of all groups, obtained between 6 and 12 years of age, were assessed by the occlusal index. Main outcome measures: the groups were compared by the chi-square test, and the mean occlusal indices between groups were compared by ANOVA and Kruskal Wallis tests (p<0.05). Results: intrarater (above 0.70) and interrater (above 0.60) was performed by kappa statistics. Group I presented highest percentage of score 5, Group II exhibited highest percentage of score 1, and Group III presented the lowest percentage of score 5 (p=0.029). Analysis grouping scores 1+2 and 4+5 did not reveal statistically significant differences between the 3 groups (p=0.142). The mean occlusal index for each group showed significant differences between groups I (4.0) and III (3.0) (p=0.022). Conclusions: early cheiloplasty with IO (grupo I) was less favorable for maxilomandibular growth compared to the other two groups operated at later ages. Group II, comprising cheiloplasty and palatoplasty at later stages + IO exhibited favorable growth, while group III without IO showed the least amount of orthodontic surgical cases prognosis. Considering the variability and limitation of the present sample, further prospective and randomized studies are warranted.
125

Protocolo de captação, processamento e transplante de enxertos osteocondrais homólogos a fresco na articulação do joelho / Protocol of procurement, processing and transplantation of fresh osteochondral allografts in the knee joint

Luís Eduardo Passarelli Tirico 07 April 2015 (has links)
O tratamento das lesões condrais e osteocondrais do joelho em pacientes jovens ainda permanece um desafio para os médicos ortopedistas. As técnicas de reparo destas lesões atualmente disponíveis no Brasil, como desbridamento, microfraturas e transplante osteocondral autólogo são insuficientes nos tratamentos das lesões condrais e osteocondrais maiores do que 4 cm2. O transplante osteocondral homólogo a fresco (TOF) na articulação do joelho vem sendo usado em outros países com excelentes resultados. Até o presente momento não existem relatos da utilização desta técnica no Brasil, fato que dificulta o tratamento de pacientes jovens ativos que necessitam de reparo biológico. Foram incluídos neste estudo oito pacientes de 15 a 45 anos portadores de lesões osteocondrais maiores que 4 cm2. Os enxertos a fresco foram obtidos de doadores de órgãos, sendo a articulação do joelho captada sem violação da cápsula articular e transportada ao Banco de Tecidos para processamento. O pareamento doador e receptor foi realizado conforme o tamanho, a localização e a prioridade em lista de espera de acordo com os tecidos captados, sendo os mesmos armazenados no meio de preservação Ham F-12 - GIBCO com glutamax (Invitrogen, Life Technologies, Estados Unidos) e com antibióticos. O procedimento cirúrgico foi realizado pelas técnicas de cilindro osteocondral e de superfície, sendo fixados quando necessário. Os pacientes foram avaliados através dos questionários de IKDC objetivo, IKDC subjetivo, KOOS e índice de Merle D\'Aubigne e Postel modificado. Foram realizados oito TOFs de março a outubro de 2012. A média de idade dos pacientes transplantados foi de 30,1 anos (17- 44 anos) e a média da área transplantada foi de 10,6 cm2 (4,6 - 22,4 cm2). O intervalo médio em dias entre captação e transplante foi de 15,3 (14 - 16 dias) e o número médio de cirurgias prévias ao TOF foi de 2 cirurgias (0-4 cirurgias). A pontuação na escala de IKDC objetiva no pré-operatório foi B em 12%, C em 25% e D em 63% dos pacientes; e 12% A e 88% B aos 18 meses de pós-operatório. A média da pontuação da escala IKDC subjetiva pré-operatória foi de 31,99 ± 13,4 e de 81,84 ± 9,25 em 18 meses de pós-operatório, e da escala KOOS pré-operatória foi de 46,8 ± 20,9 e de 89,58 ± 7,06 em 18 meses de pós-operatório, com melhora significativa ao longo do tempo (p < 0,01) pela análise da variância. A média da pontuação pelo índice de Merle D\'Aubigne e Postel modificado foi de 8,75 ± 2,25 no pré-operatório e de 16,75 ± 2,19 em 18 meses de pós-operatório. O resultado do teste de Friedman para amostras não-paramétricas demonstrou melhora significativa ao longo do tempo (p < 0,01). A padronização da captação, processamento e transplante de enxertos osteocondrais a fresco na articulação do joelho depende de um banco de tecidos altamente especializado e leva a excelentes resultados no tratamento de lesões osteocondrais grandes, sendo atualmente uma boa alternativa de tratamento biológico para pacientes jovens no Brasil / Treatment of chondral and osteochondral lesions of the knee in young patients is still a challenge for Orthopedic Surgeons. The techniques available nowadays in Brazil, as debridement, microfracture and autologous osteochondral transplantation are insufficient for the treatment of chondral and osteochondral lesions larger than 4 cm2. Fresh osteochondral allografts on the knee joint have been used in other countries with great success. Until the present days there are no reports of the utilization of this technique in Brazil, a fact that creates boundaries for the treatment of young active patients that need cartilage repair treatment. Eight patients with age ranging from 15 to 45 years old and osteochondral lesions larger than 4 cm2 were included in this study. Fresh grafts were obtained from organ donors and the knee joint was harvest without violation of synovium capsule and then was transported to the tissue bank for processing. Donor and receptor tissue matching occurred according to size, localization and priority on waiting list and tissue was preserved in Ham F-12 - GIBCO media with glutamax (Invitrogen, Life Technologies, United States) and antibiotics. Surgical procedure was achieved with osteochondral plugs or shell techniques, with additional fixation when needed. Patients were evaluated with IKDC objective, IKDC subjective, KOOS and modified Merle D\'Aubigne-Postel outcome scores. Eight fresh osteochondral allografts were performed from march to october, 2012. The average age was 30.1 years old (17-44) and mean graft surface area was 10.6 cm2 (4.6 - 22.4 cm2). Average time from harvest to transplantation was 15.3 days (14-16 days) and mean number of previous surgical procedures was 2 (0 - 4 procedures). Pre-operative objective IKDC score was B in 12%, C in 25% and D in 63% and was A in 12% and B in 88% in 18 months follow-up. Pre-operative IKDC subjective and KOOS score were 31.99 ± 13.4 and 46.8 ± 20.9; and in 18 months follow-up were 81.84 ± 9.25 and 89.58 ± 7.06, respectively, with a significant increase along time on variance analysis (p < 0.01). Pre-operative mean modified Merle D\'Aubigne-Postel scores were 8.75 ± 2.25 and 16.75 ± 2.19 in 18 months follow-up. Non-parametric Friedman test analysis showed a significant progression in follow-up (p < 0.01). Standards of procurement, processing and utilization of fresh osteochondral allografts in the knee joint relay on a high specialized tissue bank and promote excellent results on the treatment of large osteochondral lesions, being a good alternative of a biologic repair for young patients in Brazil
126

Avaliação estrutural do osso terceiro metacarpiano equino frente à implantação de biopolímero à base de mamona / Structural evaluation of the third metacarpal bone against the implantation of biopolymer based on castor oil

Mariana Baroni Selim 23 January 2014 (has links)
Uma série de novas estratégias vem sendo desenvolvidas com o objetivo de otimizar a reparação óssea, pois os métodos atualmente disponíveis em ortopedia humana e veterinária não apresentam resultados plenamente satisfatórios. Inúmeros pesquisadores dedicam-se ao desenvolvimento e estudo da compatibilidade de novos implantes com o propósito de acelerar a reparação óssea. O polímero a base de óleo de mamona tem chamado atenção para a sua aplicação como substituto ósseo, pois é um produto natural, biocompatível e com propriedades estruturais semelhantes às do tecido ósseo. Seis equinos foram submetidos à ostectomia na superfície diafisária dorsal de seus terceiros metacarpianos. Uma das falhas ósseas foi preenchida com o polímero a base de mamona e o outra, no membro contralateral permaneceu sem preenchimento, atuando como controle. Os animais foram acompanhados por um período de 120 dias após o procedimento através de monitoramento radiográfico da densidade óssea. Após este período, realizou-se biópsia para avaliação histológica por microscopias de luz e eletrônica de varredura. A densitometria óptica revelou valores médios de 14,17mmAl ± 1,722 e 16,33mmAl ±1,633 (p=0,027) para os grupos polímero e controle, respectivamente. A microscopia óptica de luz demonstrou maior porcentagem de tecido ósseo neoformado no grupo controle (50,15% ±14,83) quando comparado ao grupo polímero (26,94% ±12,06), com p0,0001. No entanto, a microscopia eletrônica de varredura permitiu observar que a qualidade do tecido ósseo formado na presença do biomaterial foi mantida. Além disso, não foram observadas reações adversas ao biomaterial, como a formação de tecido cicatricial ou reações de corpo estranho, levando a conclusão de que a poliuretana de óleo de mamona pode ser considerada adequada ao preenchimento de falhas ósseas em equinos, uma vez que desmonstrou compatibilidade e osteocondutividade. / A series of new strategies have been developed in order to optimize bone repair, because the methods currently available for human and veterinary orthopedics have no fully satisfactory results. Many researchers have dedicated to develop and study the compatibility of new implants in order to accelerate bone repair. The polymer of castor oil have drawn attention for its application as a bone substitute because it is a natural, biocompatible and have structural properties similar to bone tissue. Six horses were submited to ostectomy on the dorsal surface of its third metacarpal bone. One of the bone defects was filled with polymer of castor oil and the other remained unfilled, as a control group. The animals were followed for a period of 120 days after the procedure by monitoring radiographic bone density. After this period, a biopsy was performed for histological evaluation by light and scanning electron microscopy. The optical densitometry revealed medium values of 14.17mmAl ± 1.722 and 16.33mmAl ± 1.633 (p = 0.027) for the polymer and control groups, respectively. The light microscopy showed a higher percentage of new bone formation in the control group ( 50.15% ± 14.83 ) than in the polymer group ( 26.94 % ± 12.06 ) , with p 0.0001. However, scanning electron microscopy allowed to observe that the quality of bone formation tissue in the presence of biomaterial was maintained. Furthermore, there were no adverse reactions to biomaterial, such as scar formation or as a foreign body reaction, allowing to conclude that the polymer of castor oil can be considered suitable to fill bone defects in horses, since it demonstrated compatibility and osteoconductivity.
127

Avaliação da interação biológica entre polímero de poliuretana de mamona acrescido de carbonato de cálcio e tecido ósseo de equinos / Biocompatibility of castor oil-calcium carbonate polymer with the equine bone tissue

Fernanda Silveira Nóbrega 06 June 2014 (has links)
A reconstrução anatômica de fraturas em ossos longos em equinos é um grande desafio para o Médico Veterinário. Na tentativa de melhorar os resultados da técnica, estabilizando e preenchendo áreas onde houve perda óssea, o uso de substitutos ósseos, entre eles os biomateriais, vêm apresentando bons resultados. Os polímeros podem ser uma opção viável, funcional e economicamente, de substituto ósseo para aplicação em ortopedia de equinos. O objetivo deste estudo foi avaliar o comportamento biológico do equino frente à implantação de polímero de poliuretana de mamona acrescido de carbonato de cálcio após implante em osso III metacarpiano. Seis equinos hígidos foram submetidos à ostectomias unicorticais de 13mm de diâmetro na região proximal da superfície dorsal do III metacarpiano. Em seguida, de forma randômica, foi implantado o polímero de mamona em um membro torácico. No membro contralateral, foi reproduzida a técnica, porém a falha foi mantida sem preenchimento, servindo como controle do remodelamento ósseo. Todos os animais foram submetidos à avaliação física, radiográfica, ultrassonográfica, termográfica e perfil bioquímico previamente a cirurgia para identificação dos parâmetros pré-cirúrgicos. No período pós-operatório, os animais foram avaliados através de exame físico diário durante os 120 dias de observação, exame radiográfico, exame ultrassonográfico, exame termográfico e monitoramento do perfil sérico da fosfatase alcalina, cálcio e fósforo nos momentos sete, 15, 30, 60, 90 e 120 dias de pós-operatório. Com 120 dias de pós-operatório, novamente sob anestesia geral, realizou-se biópsia óssea com trefina de 0,5cm de diâmetro na área de interface implante-osso (membro polímero) e osso-osso neoformado (membro controle). O material foi processado e desmineralizado para microscopia de luz sendo realizadas técnicas de coloração de Hematoxilina-Eosina e Tricrômico de Masson para análise descritiva e morfométrica. A avaliação física de cada animal demonstrou não haver desconforto relacionado ao procedimento e à presença do implante, baseando-se na análise de presença de claudicação e parâmetros físicos (frequência cardíaca, frequência respiratória e temperatura retal) ao longo dos 120 dias. A avaliação ultrassonográfica permitiu identificação da formação de tecido mineralizado e pico de neovascularização no 30º dia de pós-operatório. A partir da dosagem sérica de fosfatase alcalina foi possível identificar pico desta enzima também no trigésimo dia. A avaliação termográfica demonstrou não haver aumento de temperatura local, decorrente de resposta inflamatória, ao longo do tempo de observação, porém foi possível identificar resposta mais intensa no 7º dia no membro polímero, quando comparado ao membro controle. O estudo histológico demonstrou comportamento osteocondutor do polímero sem reação de cápsula fibrosa ou resposta inflamatória crônica. Esta pesquisa apresentou resultados que demonstram biocompatibilidade do polímero de poliuretana de mamona acrescido de carbonato de cálcio em tecido ósseo equino e conclui-se que este biomaterial apresenta potencial para uso como substituto ósseo em equinos. / Anatomical reconstruction of long bone fractures remains a challenge to the equine practitioner to date. Bone surrogate biomaterials have been developed to improve surgical outcomes in cases involving bone tissue loss, with promising results. Biopolymers may be a feasible, functional and economically viable alternative for bone substitution in horses. This study evaluated the biological behaviour of castor oil-calcium carbonate polymer following implantation in the equine third metacarpal bone. Six healthy horses were submitted to bilateral dorsal unicortical osteotomy (13 mm in diameter) on the proximal aspect of the third metacarpal bone. One front limb was randomly selected for castor oil polymer implantation while the contralateral limb was left untreated to serve as control for bone remodeling. Preoperative evaluation consisted of physical, radiographic, ultrasonographic and thermographic assessment, and serum biochemistry profile determination. Horses were submitted to daily physical examination during the 120-day follow-up period. Radiographic, ultrasonographic and thermographic reassessments were performed on postoperative days seven, 15, 30, 60, 90 and 120, along with determination of alkaline phosphatase, calcium and phosphorus serum levels. On postoperative day 120, horses were reoperated under general anesthesia and a 0.5 mm biopsy fragment collected from the bone-implant or bone-new bone interface. Biopsy specimens were processed, demineralized, stained with hematoxylin-eosin or Massons trichrome and submitted to descriptive and morphometric analysis under light microscopy. Horses showed no signs of pain (i.e. lameness or changes in rectal temperature, heart and respiratory rates) related to the surgical procedure or the presence of the implant during the 120-day follow-up period. Ultrasonographic reassessment revealed mineralized tissue formation and peak neovascularization on postoperative day 30. Peak alkaline phosphatase levels were also observed on the same day. Local temperature differed significantly between treated and control limbs on postoperative day 7, but not thereafter. Absence of encapsulation or signs of chronic inflammatory response on histology suggests osteoconductive behaviour of the Ricinus communis polymer. Based on the results of this study, castor oil-calcium carbonate polymer is biocompatible with the equine bone tissue and represents a potential surrogate biomaterial for bone substitution in horses.
128

Avaliação radiográfica, histomorfométrica e de função de vôo após fixação de osteotomias distais de úmero em pombas (Columba livia), com modelo inédito de fixador externo articulado. Estudo comparativo de fixador transarticular dinâmico e estático / Radiographic histomorphometric and of flight function evaluations after distal humeral osteotomies in pigeons (Columba livia), with inedit articulated external fixator. Comparative study of dynamic and static transarticular fixators

Vanessa Couto de Magalhães Ferraz 26 September 2008 (has links)
O tratamento de fraturas umerais distais em aves impõe grande dificuldade, devido a córtices muito finas dos ossos A artrodese com fixador externo da articulação úmero-rádio-ulnar é inviável para aves que se pretende reintroduzir ao meio ambiente. Doze animais foram divididos em dois grupos: cirurgias bilaterais com anquilose de uma asa (asa estática) e manutenção da articulação da outra (asa dinâmica) (grupo 1), e cirurgia unilateral, com manutenção da função da articulação (asa dinâmica), sendo a outra controle (asa intacta) (grupo 2). Foram feitas avaliações clínicas, radiológicas, morfológicas do osso, histomorfométricas (de ambos os grupos) e de capacidade de vôo (grupo 2). A 6 semanas, todos os animais apresentavam fraturas consolidadas, com excessão de dois animais do grupo 1, que somente apresentaram consolidação das asas dinâmicas às 9 semanas e das estáticas às 12 semanas. Todos os animais do grupo 2 apresentaram capacidade de vôo adequada, antes de 13 semanas após a cirurgia. No grupo 1 o úmero da asa dinâmica representava 99,1% do comprimento do da asa estática, e no grupo 2, estes eram 99,5% em relação à asa intacta. A amplitude da asa, no grupo 2, demonstrou que a relação da asa dinâmica/intacta foi de 93%, e no grupo 1 a relação asa dinâmica/estática foi de 105%. O volume do osso intacto foi de aproximadamente 29% da área estudada, enquanto o da asa estática foi de 19% e das asas dinâmicas, de 22%. Houve diferença entre o número de osteoblástos das asas intactas e dinâmicas, porém não houve diferença entre as asas estáticas e intactas e entre as dinâmicas e as estáticas, e também não houve diferença do número de osteoclástos entre nenhum tipo de asa. A razão da superfície óssea pelo volume ósseo indica a quantidade de áreas de reabsorção. Não houve diferença entre as asas estática e dinâmica, porém houve diferença entre estas e os controles. O método proposto de técnica para fixação de fraturas umerais distais, sem a anquilose da articulação úmero-rádio-ulnar, demonstrou ser efetivo em manter o comprimento ósseo, a amplitude da asa e assim, garantindo a capacidade de vôo das aves tratadas, além de demonstrar ser equivalente histológicamente à técnica tradicional e mais estável de anquilose da articulação, para este tipo de fratura, e até mesmo, no período estudado, ser equivalente ao osso são, sendo um método adequado para a reparação de fraturas distais de úmero em aves quando se pretende a reabilitação destes animais. / The treatment of humeral distal fractures in birds is very difficult, because these bones are very brittle. Ankylosis of the humeral-radio-ulnar joint with an external fixator is unviable for birds intended for re-habilitation and reintroduction. Twelve animals were used and they were divided in two groups: bilateral surgeries, with ankylosis of one wing (static wing) and maintenance of the joint function of the other wing (dynamic wing) (group 1), and unilateral surgery, with maintenance of the joint function of the wing (dynamic wing), and the other was used as control group (intact wing) (group 2). Clinical, radiographic, morphologic and histomorphometric evaluations of the wings and bones (of both groups) and of evaluations of flight capacity (in group 2) were made. At 6 weeks, all animals had healed fractures, except two animals in group 1, that only presented consolidation of the dynamic wing at 9 weeks and the static wings at 12 weeks. All animals in group 2 were capable of flying before 13 weeks after surgery. In group 1, the humerus of the dynamic wing was 99.1% the length of that of the static wing, and in group 2, these were 99.5% compared to the intact wing. Wing amplitude, in group 2, showed a dynamic/ intact ratio of 93%, and in group 1 the dynamic/ static wing ratio was 105%. The volume of the intact bone was approximately 29% of the studied area, while in the static wing it was of 19% and in the dynamic wing, 22%. There was a difference in the number of osteoblasts of the intact and dynamic wings, but there was no difference between static and intact, and between dynamic and static wings, and also, there was no difference in the numbers of osteoclasts between any wings. The bone surface/ volume ratio indicates the amount of resorption areas. There was no significant difference between static and dynamic wings, but there was a difference between static and intact wings. The proposed method of distal humeral fracture fixation technique, without ankylosis of the humerus-radius-ulna joint, demonstrated being effective in keeping bone length, wing amplitude e therefore, guaranteeing flight capacity of the birds treated, as well as being histologically equivalent to the tradicional, more stable, joint ankylosis technique, for thise kind of fracture, and even, for the studied period, being equivalent to healthy bone, being an adequate method for fracture repair for this kind of fracture in birds, when one intends rehabilitation of these animals.
129

Estudo biomecânico comparativo entre novo sistema de bloqueio (PAX) e sistema convencional de bloqueio (Synthes) em ensaios de arrancamento e teste de quatro pontos / Biomechanical study comparing new locking plate system (PAX) and conventional locking plate system (Synthes) in pullout and four points test.

Renato Albuquerque de Oliveira Cavalcanti 20 January 2015 (has links)
Os materiais utilizados nas osteossínteses passam constantemente por avanços tecnológicos. Um dos mais recentes dispositivos é a chamada placa bloqueada, suas principais indicações são fraturas com alto grau de cominução, fraturas que não exigem uma redução anatômica, ossos osteopenicos, por exemplo, acometidos pela osteoporose, entre outras. Atualmente novos modelos de placas com bloqueio estão sendo desenvolvidos, onde a interface do parafuso e a placa são feito pela deformação do orifício, com a vantagem da instalação do parafuso em diversos ângulos. O presente projeto tem por objetivo estudar comparativamente a diferença entre os dois tipos de interface parafuso placa, como também realizar teste de quatro pontos comparando o sistema novo de bloqueio com o sistema convencional de bloqueio. Realizamos ensaios de arrancamento com sistema convencional de bloqueio (Synthes) e com o novo sistema de bloqueio (PAX) em parafusos 2,0mm; 2,4mm; 2,7mm e 3,5mm. Em todos os grupos testados o sistema convencional de bloqueio foi mais resistente e apresentou diferença significativa estatisticamente, teste de Mann- Witney (p< 0,05). Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,016; sistema 3.5 mm p= 0,008. No teste de 4 pontos utilizamos 20 placas da marca Synthes (sistema convencional de bloqueio) e 20 da marca PAX (novo sistema de bloqueio) e o sistema convencional de bloqueio se mostrou novamente mais resistente com diferença significativa. Os valores de P obtidos foram: sistema 2.0mm p = 0,008; sistema 2.4 mm p= 0,008; sistema 2.7 mm p= 0,008; sistema 3.5 mm p= 0,008. Conclui-se que o sistema convencional de bloqueio se mostrou mais resistente tanto no teste de arrancamento quanto no teste de flexão de quatro pontos. / The materials used in osteosynthesis constantly technological advances. One of the most recent devices is called the locking plate, its main indications are fractures with a high degree of comminution, fractures which do not require anatomical reduction, osteopenic bones, for example, affected by osteoporosis, among others. Currently new locking plate designs are being developed, where the screw interface and the plate are made by deformation of the hole, with the installation of the advantage screw at various angles. This study aims to compared the difference between the two types of interface screw - plate but also perform four-point test comparing the new locking system with the conventional system lock. Pullout tests conducted with conventional locking system (Synthes) and the new locking system (PAX) by screws 2.0mm; 2.4mm; 2.7mm and 3.5mm. In all groups tested the conventional system of blockade was stronger and showed a statistically significant difference, Mann-Witney test (p <0.05). P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; System 2.7 mm p = 0.016; system 3.5 mm p = 0.008. In test points 4 used 20 Synthes plate mark (conventional blocking system) and 20 brand PAX (new locking system), the conventional locking system again showed a significant difference resistant. P values were obtained: System 2.0mm P = 0.008; system 2.4 mm p = 0.008; system 2.7 mm p = 0.008; system 3.5 mm p = 0.008. It follows that the conventional locking system has proved much more resistant peel test as in the four point bending test.
130

The Microstructure and the Electrochemical Behavior of Cobalt Chromium Molybdenum Alloys from Retrieved Hip Implants

Emerson, Christopher P 12 May 2015 (has links)
Because of their excellent mechanical, tribological, and electrochemical properties, Cobalt Chromium Molybdenum alloys have been used as the material for both the stem and head of modular hip implants. Corrosion is one mechanism by which metal debris, from these implants, is generated, which can lead to adverse events that requires revision surgery. Manufacturing process such as wrought, as-cast, and powder metallurgy influences the microstructure, material properties, and performance of these implants The current research focuses on analyzing the microstructure of CoCrMo alloys from retrieved hip implants with optical and scanning electron microscopy. Additionally, energy disperse spectroscopy was utilized to determine weight composition of cobalt, chromium, and molybdenum in solution. Potentiodynamic polarization was used as an accelerated corrosion testing method to determine the electrochemical behavior of the different microstructures. In agreement with prior literature, it was found that Low Carbon Wrought CoCrMo Alloys have the best corrosion resistance properties.

Page generated in 0.0521 seconds