• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 227
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 228
  • 228
  • 162
  • 156
  • 42
  • 34
  • 33
  • 33
  • 31
  • 30
  • 29
  • 27
  • 25
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Influência do processamento de próteses totais maxilares com diferentes espessuras da base: análise gráfica da movimentação dos dentes artificiais

Mazaro, José Vitor Quinelli [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-15Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1 mazaro_jvq_me_araca.pdf: 2035782 bytes, checksum: e67d1a0017e9c678266d158062acc962 (MD5) / Universidade Estadual Paulista (UNESP) / A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... . / The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below).
212

Avaliação clínica da estabilidade dimensional de próteses totais submetidas à desinfecção por microondas /

Basso, Michael Frederico Manzolli. January 2009 (has links)
Resumo: A energia por microondas tem sido recomendada para desinfetar próteses totais. Entretanto, os ciclos de desinfecção podem afetar a estabilidade dimensional das bases de próteses. Assim, o objetivo deste estudo clínico foi avaliar o efeito de dois protocolos de desinfecção por microondas na estabilidade dimensional de próteses totais, analisando a estabilidade dimensional linear, o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos e as ocorrências clínicas. Foram confeccionadas próteses totais para quarenta pacientes totalmente edêntulos. Todas as próteses foram prensadas com a resina Lucitone 550. Após a colocação, aguardou-se 30 dias para submeter as próteses às condições experimentais como a seguir: Grupo 1 (G1)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), uma vez por semana, durante 4 semanas. Grupo 2 (G2)- 20 pacientes tiveram as próteses maxilares submetidas a desinfecção por microondas (650 W / 3 minutos), três vezes por semana, durante 4 semanas. Para avaliar a estabilidade dimensional linear, mensurações foram realizadas entre quatro pontos de referência (primeiros pré-molares e segundos molares bilateralmente) antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção. Um software foi utilizado para mensurar as distâncias entre os pontos de referência a partir de fotografias padronizadas. As dimensões médiolateral e anteroposterior e a área foram calculadas. Os dados foram analisados pelos testes ANOVA two-way, Tukey e t-Student (_=0,05). O sistema T-Scan III foi utilizado para avaliar o percentual de força oclusal obtido a partir dos contatos oclusais cêntricos. Os contatos oclusais cêntricos foram capturados, antes da primeira desinfecção por microondas (baseline) e após cada semana de desinfecção, por meio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Microwave energy has been recommended for disinfecting complete dentures. However, the microwave disinfection cycles may affect the dimensional stability of denture bases. Therefore, the purpose of this clinical study was to evaluate the effect of two microwave disinfection protocols on the dimensional stability of complete dentures, analyzing the linear dimensional stability, the percent occlusal force obtained from centric occlusal contacts and the clinical events. Complete dentures were constructed for forty totally edentulous patients. All dentures were conventionally processed with heat-polymerized acrylic resin (Lucitone 550). After insertion of complete dentures, it was expected 30 days to submit the dentures to the experimental conditions as follows: Group 1 (G1)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), once a week, for four weeks. Group 2 (G2)- 20 patients had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 minutes), three times a week, for four weeks. To evaluate the linear dimensional stability, measurements were taken across four reference points (first premolars and second molars bilaterally) before of first microwave disinfection (baseline) and after each week of disinfection. Software was used to measure distances between reference points from standardized photographs. Mediolateral and anteroposterior dimensions and area between reference points were calculated. The dimensional data obtained were analyzed using two-way ANOVA, Tukey test and t test (_ = .05). To evaluate the percent occlusal force obtained from centric occlusal contacts, the T-Scan III system was used. The centric occlusal contacts were measured, before of first microwave disinfection (baseline) and after each week of disinfection, using pressure-sensitive sheets and studied in T-Scan software. The occlusal data... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Marco Antonio Compagnoni / Banca: Raphael Freitas de Souza / Banca: Claudia Helena Lovato da Silva / Banca: Ana Claudia Pavarina / Banca: João Neudenir Arioli Filho / Doutor
213

Análise in vitro da estabilidade de próteses totais superiores implantossuportadas e implantorretidas / Analisys of the stability of maxillary overdentures An in vitro study

Aline Tany Posch 25 February 2014 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Os sistemas de retenção utilizados em próteses totais sobre implante (sobredentaduras) tem sido discutidos ao longo das últimas décadas a fim de se obter uma padronização a respeito do tratamento clínico desses pacientes. Considerando o importante papel da estabilidade das próteses para a eficiência mastigatória, bem como para elaboração do plano de tratamento adequado, o objetivo deste estudo foi avaliar a estabilidade das próteses implantossuportadas e/ou implantorretidas, utilizando para isso um estudo in vitro que simulou a força de mordida. Materiais e Métodos: Foram testadas quatro tipo diferentes de próteses totais: 1) G1 Prótese Total Removível Convencional; 2) G2 - Próteses Total Removível sobre Implantes (Overdenture), retida pelo sistema ERA; 3) G3 Prótese Total Removível sobre Implantes (Overdenture), retida pelo sistema de Barra com clipes e Encaixes - ORCE; e 4) G4 - Prótese Total Fixa sobre Implantes, seguindo o protocolo Brånemark e utilizando o sistema de barras-distais da marca Neodent. Cada grupo foi submetido ao carregamento em pontos específicos, localizados sobre os elementos 16 (F=300N), 26 (F=300N) e na região anterior 11/21(F=100N). A aferição da estabilidade foi feita através da mensuração do deslocamento vertical da prótese durante o a aplicação da força e a distância do local do carregamento, sobre os elementos 16, 26 e na região anterior, nos elementos 11 e 21. Os dados passaram no teste de normalidade de Shapiro-Wilk e foram submetidos à análise de variância ANOVA e à comparação múltipla através do teste de Bonferroni (p<0.05) Resultados: O tipo de sistema utilizado influenciou na movimentação vertical da prótese na região posterior contralateral à aplicação de força, sendo a movimentação vertical G1 > G2 > G3 &#8805; G4. Na movimentação vertical da prótese nos dentes anteriores, quando a força foi aplicada nos dentes posteriores (rotação para posterior), a movimentação vertical foi de G1 > G2 > G3 &#8805; G4. Durante a rotação para posterior, quando a força foi aplicada nos dentes anteriores (rotação para anterior) e a movimentação medida nos dentes posteriores, o comportamento foi de G1 > G2 > G3 > G4. Conclusão: Em duas das três situações testadas não houve diferença estatística entre a movimentação vertical entre o G3 e o G4, sugerindo que a estabilidade da overdenture retida por barra com clipes e encaixes se comportou, em relação a estabilidade, semelhante a prótese fixa sobre implantes. / The retain systems used by the complete dentures have been discussed over the past decades in order to achieve a standardization regarding to the clinical treatment of the patients. Considering the important meaning of the stability of dentures for chewing efficiency and for planning appropriate treatment, the aim of this study was to evaluate the stability of the implant-supported and implant-retained prosthesis, using an in vitro study that simulated the bite force. Materials and Methods: Four different types of dentures were tested: 1) G1 - Conventional Denture; 2) G2 Overdenture retained by the ERA system ; 3) G3 - Overdenture retained by bar system using clipes and fittings; and 4) G4 - Total implant-supported Prosthesis, following the Brånemark protocol and using Neodent`s distal bar. Each group was subjected to loading at specific points, located on the elements 16, 26 (F = 300Ncm) and at the anterior region 11/21 (F = 100Ncm). The measurement of vertical displacement during the test was taken out-lying from the loading area and at the elements 16, 26 and in the anterior region, at the element 11/21. Results: The data was analyzed by Shapiro -Wilk normality Test and than by ANOVA and multiple comparisons using the Bonferroni test. Conclusions: The retention system have influenced the vertical movement of the prosthesis in the posterior region contralateral to force application point, with the vertical movement as G1 > G2 > G3 > G4. In the vertical movement of the prosthesis at anterior point, when the force was applied to the posterior teeth, the vertical movement was G1 > G2 > G3 > G4. When the load was applied to the anterior teeth and movement was measured ate the posterior teeth, the behavior was G1 > G2 > G3 > G4. In two of the three situations simulated, there was no statistical difference between the vertical movement between the G3 and G4, suggesting that the stability of overdentures retained by bar with clips and fittings performed like fixed prosthesis.
214

Método simplificado versus convencional de confecção de próteses totais para aplicação na saúde pública. Parte III: avaliação da função mastigatória / Simplified versus conventional method for complete denture fabrication for application in public health. Part III: Assessment of masticatory function

Tatiana Ramirez Cunha 13 December 2011 (has links)
Métodos convencionais para a confecção de próteses totais envolvem uma série de procedimentos técnicos complexos. No entanto, métodos simplificados podem ser tão efetivos quanto os convencionais, porém é importante que a mastigação não sofra influências deletérias. Assim, o objetivo deste estudo foi comparar um método simplificado de confecção de próteses totais a outro convencional, tendo como variáveis a performance e a habilidade mastigatórias. A amostra foi formada por pacientes desdentados solicitando tratamento com próteses totais duplas. Os participantes foram divididos aleatoriamente em dois grupos: Grupo S (n=17), que recebeu próteses confeccionadas por um método simplificado, e Grupo C (n=18), que recebeu próteses confeccionadas de forma convencional. Após 3 meses da instalação das próteses, a performance mastigatória foi avaliada por um método colorimétrico, utilizando duas biocápsulas como alimento teste, após 20 e 40 ciclos mastigatórios, e a habilidade mastigatória dos participantes foi avaliada por meio de questionário (Questionário HM) e escala visual analógica (EVA). Foi feita referência dos resultados a um grupo de participantes dentados, Grupo DN (n=17). Os três grupos foram comparados por meio de testes adequados à distribuição dos dados (&alpha;=5%). A performance mastigatória foi similar nos grupos C e S e representou 31% daquela encontrada no grupo DN. A habilidade mastigatória foi semelhante para S e C independente do método de análise, sendo que algumas questões do questionário HM, analisadas isoladamente, tiveram maior ocorrência de respostas favoráveis para o primeiro. Conclui-se que métodos simplificados de confecção de próteses totais são capazes de reabilitar a mastigação de maneira comparável ao método convencional, tanto fisiologicamente como segundo as percepções do paciente. / Complete denture fabrication involves a series of complex technical procedures. Nevertheless, simplified methods may be as effective as conventional ones and mastication should not be further impaired. Therefore, this study aimed to compare a simplified method and a conventional protocol for complete denture fabrication, in terms of masticatory performance and ability. A sample was formed by edentulous patients requesting treatment with maxillary and mandibular complete dentures. Participants were randomly allocated into two groups: Group S (n=17), which received dentures fabricated by a simplified method, and Group C (n=18), which received conventionally fabricated dentures. After 3 months following insertion, masticatory performance was evaluated by means of a colorimetric assay based on chewing two capsules as test food during 20 and 40 cycles. Masticatory ability was assessed by means of a questionnaire (HM) with dichotomous answers and a single question answered by means of a visual analogue scale (VAS). A third group (DN, n=17) formed by dentate volunteers served as an external comparator. Results for the three groups were compared by means of statistical tests suitable for the distribution of data (&alpha;=5%). Groups C and S presented similar masticatory performance which corresponded to 31% of group DN. Results for masticatory ability showed similarity between S and C, regardless of the assessment method, though some isolate items of the HM questionnaire showed more favorable results for the first group. It can be concluded that simplified methods for complete denture fabrication are able to restore masticatory function to a level comparable to the conventional protocol, physiologically and according to patient perceptions.
215

Avaliação de overdentures mandibulares com diferentes sistemas de retenção: análise fotoelástica da transmissão de tensões e efeito de carga cíclica na força de retenção / Evaluation of mandibular overdentures with different attachments systems: Photoelastic stress analysis and effect of cyclic loading on retention force

Fábio Afrânio de Aguiar Junior 01 July 2013 (has links)
O surgimento dos implantes osseointegrados melhorou a qualidade de vida de pacientes edêntulos. Seu uso favorece retenção e estabilidade, gerando maior eficiência mastigatória e conforto. O objetivo deste estudo foi avaliar manutenção da força de retenção e padrões de tensões gerados na mandíbula em overdentures confeccionadas com dois sistemas de retenção retidas por 2 ou 3 implantes. Teste de carga cíclica e análise fotoelástica de tensões foram realizados. Para o teste de carga cíclica foram utilizados modelos representativos de mandíbulas desdentadas e os grupos analisados foram: A) 2 implantes com barra clipe; B) 3 implantes com barra clipe; C) 2 implantes com barra clipe e bola/o\'ring nas extremidades; D) 3 implantes com barra clipe e bola/o\'ring nas extremidades. Cinco espécimes por grupo foram submetidos à ciclagem e 5 permaneceram imersos na máquina de ciclagem (controle). As leituras de força de retenção foram realizadas por ensaio de tração em máquina de ensaios universal antes da ciclagem e a cada 500 mil ciclos. A ciclagem foi realizada com frequência de 1,8 Hz, carga de 130 N, por 2 milhões de ciclos. Para a aplicação de carga, foram feitas pontas correspondentes à arcada antagonista unilateral posterior. Os dados obtidos foram analisados estatisticamente pelo modelo linear de efeitos mistos. Para a análise fotoelástica, foi feito um modelo mestre curvo em resina acrílica. O modelo foi preparado para conter cinco implantes, paralelos, distribuídos na região interforaminal. Grupo com 4 implantes com barra clipe e o\'rings nas extremidades foi incluído como controle. Prótese total foi confeccionada e usada em todos os grupos. A cada grupo, nova captura de retentores foi realizada. Para obtenção dos modelos fotoelásticos, foram confeccionados moldes em silicone do modelo mestre. A verificação das tensões em torno dos implantes foi realizada por meio de análise fotoelástica qualitativa de transmissão sob aplicação de carga cêntrica estática de 50 N. Diferentes tipos de pontas e locais de aplicação de carga foram usados. Os resultados demonstraram que carga cíclica influencia na perda de retenção overdentures mandibulares. Comparando grupos controle e teste, observou-se que os grupos com três implantes apresentaram maior influência da ciclagem na perda de retenção. Os sistemas de retenção estudados apresentaram comportamentos diferentes até um milhão de ciclos, após não houve diferença quanto à manutenção de retenção. Todos os grupos mantiveram retenção satisfatória ao final da ciclagem. Três implantes apresentaram maior tensão ao redor dos implantes e pouca ou nenhuma sobre o rebordo. Nos grupos com dois implantes, aplicação de carga posterior gerou tensões no rebordo alveolar e implantes. Grupos com extensões distais evidenciaram uma maior tensão ao redor dos implantes que os sem extensão. / The appearance of osseointegrated dental implants improved the quality of life of fully edentulous patients. Implants promote retention and stability, producing higher masticatory efficiency and comfort. The aim of this study was analyze the retention maintenance and the stress pattern generated by two or three implants-supported mandibular overdentures with two attachments systems. Cyclic loading test and photoelastic stress analysis were performed. For the cyclic loading test, edentulous mandibular models were used. The analyzed groups were: A) 2 implants with bar clip; B) 3 implants with bar clip; C) 2 implants with bar clip and balls/o\'rings in the extremity; D) 3 implants with bar clip and balls/o\'rings in the extremity. Five specimens per group were submitted to cyclic loading and five were kept immersed inside the test machine (control group). The measurements of retention force were performed by tensile test in a universal testing machine before cyclic loading and after each 500 thousands cycles. The cycling was performed with frequency of 1.8 Hz, loading of 130 N, up to two million cycles. For the load application, tips corresponding to posterior unilateral antagonist teeth were produced. Data were statistically analyzed by linear mixed-effects model. For the photoelastic analysis, a curved master model was produced in acrylic resin. The model contained five parallel implants, distributed in interforaminal area. A group with 4 implants splinted with bar clip and balls/o\'rings in the extremity was included as a control. Complete denture was made and used in all groups. In each group, incorporating of new attachments was performed. For the obtainment of photoelastic models, silicone impression of the master model was performed. The assessment of stress around implants was done through quantitative transmission photoelastic analysis under static centric load application of 50 N. Different sorts of tips and load application places were used. The results showed that cyclic load influences the retention loss of mandibular overdentures. Comparing test and control groups, it was observed that groups with three implants showed higher influence of cyclic loading in retention loss. The studied attachments systems showed different behaviors up to one million cycles, after that there was not difference in the maintenance of retention. All groups had satisfactory retention at the end of cycling. Groups with three implants showed higher stress around implants and lower or none on alveolar ridge. In groups with two implants, load application on posterior area caused stress on alveolar ridge and implants. Groups with distal extensions demonstrated higher stress around implants than groups without extension.
216

Avaliação in vitro das variações posicionais da cabeça da mandíbula na fossa articular decorrentes da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes técnicas de processamento / In vitro evaluation of changes in the position of the mandibular condyle in consequence of dimensional changes in denture base acrylic resins submitted to different processing methods

Tatiana de Carvalho Guarnieri 11 September 2006 (has links)
Este estudo teve o objetivo de avaliar in vitro a influência da alteração dimensional de resinas acrílicas para base de prótese total submetidas a diferentes formas de processamento sobre a posição da cabeça da mandíbula, buscando estabelecer uma possível relação com a etiologia das disfunções crânio-mandibulares nos pacientes usuários desse tipo de prótese. Foram duas etapas: a primeira parte enfocou o papel do tipo de prensa (Getom ou de cozimento) e da força de prensagem para fechamento da mufla (1000 ou 1500 kgf) utilizados no processamento de duas resinas: Lucitone 550 e QC–20 e somente da força de prensagem para a resina Acron MC. Já a segunda parte do estudo teve o intuito de avaliar a influência dos ciclos de polimerização curtos e longos na alteração dimensional de cinco resinas: as mesmas três da primeira parte, além da Clássico e Ondacryl. As próteses superiores acrilizadas foram remontadas em articulador totalmente ajustável, tendo como referência a posição de máxima intercuspidação (MIC). Nessa posição de maior estabilidade oclusal, foi vazado gesso tipo IV no espaço entre as esferas condilares do articulador e as paredes dos estojos condilares. Após a cristalização, esses corpos-de-prova de gesso foram removidos do estojo condilar e suas dimensões medidas e submetidas à análise estatística por meio de um modelo de análise de variância com medidas repetidas que permitiu concluir que houve variações na posição da “cabeça da mandíbula” em 625 das 630 medidas efetuadas; as médias de movimentação condilar variaram de 0,118 (DP = 0,0968) a 1,956 mm (DP = 0,414) e ocorreram principalmente no sentido posterior do lado esquerdo; na maioria dos casos em que a força de prensagem agiu como fator devariação, os deslocamentos obtidos com 1500 kgf foram menores do que aqueles obtidos com 1000 kgf; nos casos em que o tipo de prensa agiu como fator de variação, ora os menores deslocamentos foram obtidos com a prensa de cozimento, ora com a Getom; o ciclo empregado na polimerização não influenciou significativamente na estabilidade dimensional das próteses totais e a única diferença encontrada envolveu a resina Clássico, que levou aos maiores deslocamentos no sentido posterior do lado esquerdo. / The purpose of this study was to evaluate in vitro the influence of dimensional changes in denture base acrylic resins submitted to different processing methods on the position of the mandibular condyle. This was done to establish a relation between these dimensional changes and the etiology of temporomandibular disorders in complete denture wearers. This research was divided into two parts. The first part focused on the type of press (conventional water bath or Getom), on the pressing force for flask closure (1000 or 1500 kgf) when processing Lucitone 550 and QC-20 resins, and on the pressing force when processing Acron MC resin. The purpose of the second part was to evaluate the influence of polymerization time on the dimensional stability of five resins, namely Lucitone 550, QC-20, Acron MC, Clássico and Ondacryl. The polymerized upper prostheses were remounted on a fully adjustable articulator, using the maximal intercuspal position (MIP) as reference. Type IV dental stone was poured into the space between the condylar spheres and the condylar walls. After the dental stone dried, the samples were removed from the articulator and their dimensions were measured and submitted to analysis of variance with repeated measures. The following conclusions were drawn: 625 from 630 measurements done showed changes in the position of the “mandibular condyle” and mean values for condylar movement ranged from 0.118 (SD = 0.0968) to 1.956 mm (SD = 0.414) and occurred mainly in the posterior direction on the left side; in most cases where the pressing force influenced the condylar position, the changes were smaller in 1500 kgf group than in the 1000 kgf group; in the cases where the type of press influenced the changes in condylar position, the smallest values were found in both groups, sometimes with Getom and other times with conventional water bath press; polymerization time did not significantly affect the dimensional stability of the dentures and the greatest changes occurred in the posterior direction on the left side with Clássico resin.
217

Efeito antimicrobiano residual e citotoxidade in vitro de resina acrílica para base de prótese após imersão prolongada em agentes de limpeza / In vitro residual antimicrobial effect and cytotoxicity of acrylic resin base prosthesis after long-term immersion in cleaning agents

Andréa Lemos Falcão Procópio 15 May 2015 (has links)
O presente estudo in vitro objetivou avaliar a longo prazo o potencial antimicrobiano residual e a citotoxicidade de soluções químicas de limpeza de prótese quando incorporadas à resina acrílica termopolimerizável após sucessivos ciclos de imersão noturna diária. Discos (10mm x 1mm) de resina acrílica termopolimerizável para base de prótese (Lucitone 550) foram submetidos a três ciclos diários de desinfecção (8h/cada) em hipoclorito de sódio a 1% (NaClO), digluconato de clorexidina a 2% (CLX) ou água destilada (controle) durante 91 (T91) ou 183 dias (T183), simulando o período de 9 meses ou 1,5 ano de imersão noturna diária realizada pelo paciente. Inicialmente, foi utilizado o método de concentração inibitória mínima em caldo para determinar o possível efeito residual (incorporação) das soluções à resina acrílica. Metade dos discos imersos em cada agente de limpeza em um dos tempos de imersão (n=5) foi inoculada (1x107cels/mL) com um dos patógenos associados à estomatite protética: Candida albicans (Ca) e Staphylococcus aureus (Sa). Os discos foram incubados a 37oC para análise em espectrofotômetro após 24h, 7 e 14 dias. Os valores de absorbância foram convertidos em porcentagens de inibição microbiana. Confirmada a ação antimicrobiana residual dos agentes de limpeza incorporados à resina acrílica, foi então analisada sua citotoxicidade in vitro sobre fibroblastos gengivais humanos (L929). Os efeitos citotóxicos foram avaliados por meio do ensaio colorimétrico MTT [brometo de 3-(4,5-dimetiltiazol-2-yl)-2,5-difeniltetrazólio] para a determinação da viabilidade celular, após as células serem expostas por 24h às amostras de cada condição experimentais (n=18) previamente imersas em uma das soluções por um dos períodos avaliados (T91 ou T183). A citotoxicidade foi determinada com base na atividade mitocondrial em relação a corpos de prova não submetidos à imersão nas soluções testadas. Os resultados do ensaio do MTT foram analisados estatisticamente por ANOVA-1 fator seguida pelo teste post-hoc de Tukey HSD (a=0,05). Para os períodos T91 e T183, não houve inibição microbiana com a imersão em água (controle) em até 14 dias de incubação. A CLX inibiu progressivamente o crescimento microbiano ao longo dos 14 dias para ambos os períodos de imersão (Ca: 19 a 73,58%; Sa: 0 a 87,08%), sendo observada maior ação antimicrobiana em T183. O NaClO apresentou discreta inibição microbiana apenas no período de 14 dias tanto em T91 (Ca: 0%; Sa: 2,70%) quanto em T183 (Ca: 8,50%; Sa: 15,08%). De acordo com os resultados do teste de MTT, as soluções químicas de limpeza testadas apresentaram uma redução significativa da viabilidade celular quando comparado às células controles propagadas apenas em meio de cultura (p<0,002). A CLX resultou na menor viabilidade celular em ambos os períodos de imersão (p<0,018). As amostras de resina acrílica imersas em água ou NaClO em T91 e T183 apresentaram viabilidade celular estatisticamente similar às amostras não imersas (p>0,05). Pode-se concluir que a CLX incorporada à resina acrílica para base de prótese apresentou um efeito antimicrobiano residual em ambos os períodos de imersão noturna, o que não foi observado com o NaClO. Por outro lado, a CLX residual resultou em efeito intensamente citotóxico aos fibroblastos gengivais humanos quando comparada ao NaClO e à agua destilada, que se apresentaram discretamente citotóxicos. Esses resultados sugerem precaução na seleção de agentes de limpeza para prótese como meio de prevenção e tratamento adjunto da estomatite protética, pois mesmo em concentrações baixas, recomendadas para imersão noturna, podem apresentar algum grau de toxicidade às mucosas de suporte protético. / This in vitro study aimed to evaluate the long-term residual antimicrobial activity and cytotoxicity of chemical denture cleansers incorporated into a heat-polymerized acrylic resin after successive cycles of daily overnight soaking. Discs (10mm x 1mm) were prepared from heat-polymerized acrylic resin (Lucitone 550) and submitted to three daily immersion (8h/each) in 1% sodium hypochlorite (NaClO), chlorhexidine digluconate 2% (CHX) or distilled water (control) for 91 days (T91) or 183 days (T183), simulating the period of 9 months or 1.5 year of nocturnal immersion performed by the patient. Initially, the method of minimum inhibitory concentration in broth was used to determine the possible residual effect (incorporation) of the acrylic resin solution. Half of the disks immersed in each cleaning agent for one of the period immersion (n=5) was inoculated (1x107cells/mL) with pathogens associated with denture stomatitis: Candida albicans (Ca) or Staphylococcys aureus (Sa). The disks were incubated at 37oC for analysis in a spectrophotometer after 24h, 7 and 14 days. The absorbance values were expressed as percentages of microbial inhibition. Confirmed the residual antimicrobial action of cleaning agents incorporated into the acrylic resin, its cytotoxicity was analyzed in vitro on human gingival fibroblasts (L929). Cytotoxic effects were evaluated by the colorimetric assay MTT [3- (4,5- dimethylthiazol-2-yl) -2,5-diphenyl tetrazolium bromide] to determine cellular viability after the cells were exposed for 24h to the samples of each experimental condition (n=18) previously immersed in one of the solutions for the evaluation periods (T91 or T183). Cytotoxicity was determined based on mitochondrial activity compared to the specimens not subjected to immersion in the solutions. The MTT assay results were 1-way ANOVA followed by Tukey\'s HSD post-hoc test (a=0.05). For the periods T91 and T183, no microbial inhibition was observed with immersion in water (control) for up to 14 days of incubation. The CHX progressively inhibited microbial growth over the 14 days for both immersion times (Ca: 19 to 73.58%, Sa: 0 to 87.08%); with greater antimicrobial activity in T183. The NaClO showed a slight microbial inhibition only in the 14-day period in both T91 (Ca: 0%; Sa: 2.70%) and T183 (Ca: 8.50%; Sa: 15.08%). According to the results of the MTT assay, the chemical cleaning solutions tested showed a significant reduction in cell viability when compared to the control cells propagated in normal culture medium (p<0.002). The CHX resulted in the lowest cell viability in both immersion periods (p<0.018). The acrylic samples immersed in water or NaClO in T91 and T183 showed cell viability statistically similar to nonimmersed samples (p>0.05). CHX incorporated into the acrylic resin denture base had a residual antimicrobial effect on both immersion periods, which was not observed with NaClO. On the other hand, the residual CHX were severely cytotoxic to human gingival fibroblasts compared to NaClO and distilled water which were slightly cytotoxic. These results suggest caution in selecting denture cleaning agents as a method of prevention and adjunct treatment of denture stomatitis because even at low concentrations recommended for overnight immersion, they may exhibit some degree of toxicity to the denture bearing mucosa.
218

Análise da distribuição das tensões nas estruturas de suporte de overdentures, rebordo residual e implantes, com sistema de conexão de coroas cônicas (Syncone-Dentsply). / Analysis of the tensions distribution in the structures of overdentures support, residual alveolar ridge and implants, with connection of conical crowns system (Syncone-Dentsply)

Ana Cristina Aurora Rosa Perasso Guariglia 22 March 2007 (has links)
O sistema de osseointegração desenvolvido por Branemark revolucionou o campo das reabilitações protéticas, incentivando os profissionais a indicar e realizar próteses do tipo overdentures. Estes dispositivos representam uma ótima alternativa para solucionar os problemas dos pacientes desdentados, insatisfeitos por diversos fatores. Várias são as associações entre os implantes e os sistemas de conexões empregados em overdentures. A literatura e a prática clínica fazem observar que na dependência do sistema de conexão empregado, há uma diferença no comportamento biomecânico, realizado por este conjunto: prótese/implante/conexão. Desta forma, é importante analisar como as tensões se distribuem sobre as estruturas que suportam estas cargas, uma vez que não existe o ligamento periodontal ao redor dos implantes que promove o mecanismo fisiológico, natural nos dentes. Assim, o objetivo desta investigação foi de avaliar, com o auxílio do método fotoelástico, o comportamento da distribuição das tensões em sobredentaduras (overdentures), suportadas por quatro implantes Ankylos®/ Dentsply®, utilizando-se o sistema protético de conexão de coroas cônicas Syncone®/ Dentsply®, onde se comparou duas formas de distribuição dos implantes, na primeira (CPM1) os implantes foram posicionados nas regiões de incisivos centrais e pré-molares e o segundo (CPM2) os implantes estavam posicionados nas regiões de caninos e pré-molares. Os modelos receberam cargas de forma crescente de 0,0 a 9,0 kg e, as tensões resultantes nas estruturas de suporte, foram analisadas fotoelasticamente. De acordo com a metodologia empregada nesta pesquisa, somos levados a concluir que: 1) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre quatro implantes, sendo 2 localizados na região de incisivos centrais e 2 situados, diametralmente opostos, na região de segundos pré-molares na mandíbula - CPM1 - o rebordo residual é quem recebe a maior quantidade de tensões em relação aos implantes; 2) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre 4 implantes, dispostos 2 a 2, bilateralmente e diametralmente opostos, nas regiões de caninos e pré-molares, na mandíbula (CPM2), as maiores tensões são transmitidas ao rebordo residual, sendo que os implantes suportes resultam mais preservados; 3) Comparativamente, o CPM2, aparenta ter transmitido menores tensões aos implantes que o CPM1; 4) Os implantes são preservados quanto à ocorrência de uma sobrecarga, durante a máxima intercuspidação dos arcos dentários, quando se emprega o sistema Syncone® associado à overdenture ou sobredentadura. / The osseo-integrated system develop by Branemark has revolutionized the prosthetic rehabilitation field, encourage the professionals to indicate and perform prostheses like overdentures. These devices represent an optimal alternative to solve the full dentures patient?s problems, dissatisfied for diverse factors. There are several associations between implants and prosthetic connectors employees for overdentures. The literature and the clinic practice may observe that according of the connection system employed, there is a difference into the biomechanical behavior, realized for this set: prostheses/implant/connection. From this forms, it is important to analyze how the tensions are distributing on the structures subject that support these loads, since it doesn\'t exist the periodontal ligament around the implants, what promotes the physiological mechanism of the natural teeth. Such, the purpose from this investigation was appraising, with the aid of the photoelastic method, the distribution way from the tensions at the overdentures, supported by four implants Ankylos®/ Dentsply, by using the prosthetic system of connection of conic crowns ? Syncone®/ Dentsply, were applied loads from 0,0 to 9,0kg, in crescent forms and, the tensions resulting on the support structures, have been analyzed by the photoelasthic method. Where two forms of distribution of the implantations were compared, first (CPM1) the implants were located at the regions of the central incisors and pre-molar, and as (CPM2) the implants were located at the regions of canines and pre-molar. The models had received loads of increasing form, from 0,0 to 9,0 kg and, the resultant tensions in the support structures, had been analyzed by the photoelastic method. In agreement with the methodology used in this research, we are led to conclude that: 1) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, being 2 located in the region of central incisors and 2, diametrical opposing ones, in the region of the second pre-molar (CPM1) the residual alveolar ridge is who receives the biggest amount of tensions in relation to the implants; 2) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, bilaterally and diametrical opposing ones, in the regions of canine and pre molar (CPM2), the biggest tensions were transmitted to the residual alveolar ridge, being the implants supports resulted more preserved; 3) Comparatively, the CPM2, seems to have transmitted less tensions to the implants than the CPM1; 4) The implants were preserved as the occurrence of an overload, during the maximum intercuspidação of the dental arcs, when the overdenture associated with Syncone® system has been used.
219

Avaliação das guias condilar e incisal em função da curva de compensação e da altura das cúspides - Releitura das Leis de Articulação de Hanau / Evaluation of condylar guidance and incisal guidance according to the compensating curve and cusp heights. A review of Hanaus laws of articulation

Roger Nishyama 19 April 2011 (has links)
Este estudo teve como objetivo avaliar a variação das guias sagitais (guia condilar e guia incisal), em função do plano de orientação (curvatura e inclinação) e da altura das cúspides, no movimento protrusivo mandibular, in vitro, buscando as relações entre esses fatores, tanto de forma analógica como digital. No estudo analógico foram avaliadas as inclinações das guias condilares, inclinações da guia incisal, proeminência da curva de compensação e inclinação do plano oclusal. Para isso foram utilizados planos de orientação prototipados com a proeminência da curva de compensação pré definidas por calotas de esferas de 7, 8 ou 9 polegadas de diâmetro. Para cada proeminência da curva de compensação haviam 3 inclinações antero-posterior também pré definidas em: planos iniciais, ou planos 0, planos com um aumento da inclinação de 5 graus em relação ao primeiro, ou plano +5, e planos com uma inclinação 5 graus menor que o primeiro, ou plano -5. Com um par planos de orientação montados no articulador não arcon Bio-art EVA Plus ajustou-se as guias condilares e incisal, após isso foi aumentada a inclinação da guia condilar e observadas as alterações necessárias nos outros três fatores, inclinação da guia incisal, proeminência da curva de compensação e inclinação do plano oclusal, cada uma em seu determinado momento, para se restabelecer o ajuste do articulador. Esse procedimento foi repetido alterando-se cada um dos outros 3 fatores gerando assim 6 condições experimentais analógicas. No estudo digital foram avaliadas as inclinações das guias condilares, inclinações da guia incisal, proeminência da curva de compensação, inclinação do plano oclusal e altura das cúspides dos dentes posteriores. Para isso, o articulador Bio-art EVA Plus foi reproduzido no programa Adobe Photoshop CS3 juntamente com os planos de orientação e as simulações de cúspides e de dentes anteriores. Da mesma forma que o estudo analógico iniciou-se com os planos de orientação em posição e o articulador com as guias condilares e guia incisal ajustadas; foi aumentada a inclinação da guia condilar e observado no movimento de protrusão o comportamento dos outros 4 fatores, cada um em um determinado momento, para o restabelecimento da oclusão bilaterla balanceada. Esse procedimento foi repetido com cada um dos outros 4 fatores gerando assim 10 condições experimentais virtuais. Os resultados permitiram concluir que existe uma relação entre a inclinação da guia condilar, inclinação da guia incisal, proeminência da curva de compesação, inclinação da curva de compensação e altura das cúspides, na obtenção da oclusão bilateral balanceada, e esta relação comprova as descritas por Hanau em seus estudos. / The objective of this in vitro study was to evaluate the variation of the saggital guidances (condylar guidance and incisal guidance) according to plane of orientation (prominence and inclination) and cusp heights during mandibular protrusive movements. The relationship between afore mentioned factors were assessed through both analogical and digital methods. In the analogical study, the inclination of condylar guidance and incisal guidance, prominence of compensating curve and the inclination of the occlusal plane were evaluated. In order to do so, prototyped guiding planes with compensating curves prominence pre-defined by spheres of 7, 8 and 9 inches of diameter were used. For each compensating curves prominence, there were also 3 pre-defined antero-posterior inclinations: initial planes (plane 0), planes with a 5-degree inclination increase (plane +5) and planes with a 5-degree inclination decrease (plane -5). A pair of guiding planes was mounted on a non-arcon Bio-art EVA Plus articulator and condylar and incisal guidances were adjusted. As the condylar guidance was increased, the changes necessary to reestablish the articulators adjustment were observed for the other three factors: incisal guidances inclination, prominence of compensating curve and occlusal planes inclination. This procedure was repeated altering each one of the other three factors resulting in 6 analogical experimental conditions. In the digital study, condylar guidance inclination, incisal guidance inclination, compensating curve prominence, occlusal plane inclination and posterior teeths cusp heights were evaluated. In order to do so, the Bio-art EVA Plus articulator, guiding planes and simulations of the cusps and anterior teeth were reproduced in the Adobe Photoshop CS3 program As performed at the analogical study, the guiding planes were put into position and the condylar and incisal guidances were adjusted. The condylar guidance inclination was increased and the changes in the other 4 factors were observed in the protrusive moment so that the bilateral balanced occlusion could be reestablished. This procedure was repeated with each one of the 4 factors resulting in 10 virtual experimental conditions. The results showed that there is a relationship between the condylar guidance inclination, incisal guidance inclination, prominence of the compensating curve and the cusp heights when achieving bilateral balanced occlusion and the results obtained in the current study is in accordance with those obtained by Hanau.
220

"Avaliação da alteração dimensional da base de prova permanente da prótese total de resina acrílica ativada termicamente, processada em forno microondas, por meio da imagem digital" / Evaluation of the dimensional alteration according to the permanent proof base for complete denture made of thermally activated acrylic resin, in microwave process, using digital image

Lima, Ana Paula Barbosa de 11 August 2006 (has links)
Foram confeccionados 50 corpos de prova, divididos em 30 próteses totais superiores e 20 bases de provas permanentes, padronizados, para se avaliar a alteração dimensional da base de prova permanente, com dupla polimerização, processada em forno de microondas convencional; base de prova permanente com dupla polimerização, processada no método convencional; e a prótese total em uma única polimerização. Para essa análise, essas próteses foram divididas em 5 grupos: grupo I – prótese total convencional – banho de água (controle); grupo II – base de prova permanente processada convencionalmente; grupo III – base de prova permanente processada em forno de microondas convencional; grupo IV – prótese total superior padronizada com base de prova permanente processada convencionalmente, com as bases do grupo II; grupo V – prótese total superior com base de prova permanente, processada no forno de microondas convencional, com as bases de prova do grupo III. Para avaliar essa alteração foi usado o recurso do scaneamento da região posterior das próteses, “Post-dam", desses corpos de prova. Após esse processo, a imagem capturada foi levada para o programa Photoshop 8.0 determinando a região de avaliação. Após essa seleção, a imagem é acessada no CorelTrace 11 para ser transformada em preto e branco e vetorizada, sendo, então, levada para o CorelDraw 11 para ser feita a medição do espaço da região posterior, entre o modelo e a base de prova/prótese total, para permitir a análise dos valores da alteração dimensional dos corpos de prova em questão, após o processamento. Os resultados mostram que: 1) a diferença da variação média para os lados esquerdo, centro e direito, respectivamente, na ordem de décimos ou centésimos de milímetros, para o grupo IV e I (0,07; 0,08 e 0,09); para o grupo V e I (0,10; 0,32 e 0,25) e para o grupo V e IV (0,17; 0,24 e 0,16) não pode ser considerada relevante clinicamente para afetar o ajuste da prótese na boca e promover a ocorrência de maiores transtornos clínicos; 2) A alteração média das áreas do lado esquerdo e direito para o grupo I, II e IV obtiveram uma homogeneidade na alteração, diferindo os Grupos III e V em relação aos outros, não existindo porém, diferença significante a nível de 5% entre as áreas desses segmentos; 3) A análise da variância do índice da área dos cinco (5) grupos não apresentou resultado significante que desabonasse a utilização de qualquer um dos métodos para a confecção da prótese total. No entanto, mais estudos devem ser realizados com o intuito de se aprimorar o uso do forno de microondas para o processamentos da prótese. / The 50 samples of pattern maxillary complete denture were processed, divided in 30 maxillary complete denture and 20 permanent proof base, to evaluated of dimensional changes in the permanent proof base with twice polymerization, process in microwave oven, to compare with the others two groups, the complete denture with conventional process and the complete denture with permanent proof base with twice polymerization in a conventional process. To evaluated this complete dentures they were divided in 5 groups: group I – conventional complete denture; group II – proof base conventional process; group III – proof base in microwave process; group IV – complete denture using the proof base of the group, with the conventional process and the group; group V – complete denture using the proof base of the group III, microwave process. To evaluated this alteration used the scanner in the “Post-dam", in this samples. After this proceding the image was putting in the Adobe Photoshop 8.0 program to determinate what region was evaluated. After this selection, the image access in the CorelTrace 11 program and transformed in black and white, and after to access in the CorelDraw 11 that was measured the region between the cast and the complete/permanent proof base, to allow the analysis of the values the dimensional alteration of the proof body, after the process. The results show: 1) The linear dimensional alteration the difference mean variation for the left, center and right sides, respectively, it was in decimal order or centesimal of millimeters, for the group IV and I (0,07; 0,08 and 0,09); and for the group V and I were (0,10; 0,32 and 0,25) and for the group V and IV (0,17; 0,24 and 0,16) and it cannot be considered clinically relevant to affect the prosthesis adjustment in the mouth, and promote the occurrence of more clinical disruptions; 2) The dimensional alterations in the areas (left and right side) of the proof bodies of the three groups I, II and IV were uniform, and the groups III and V weren’t homogeneous, but there is not a statically significant difference, about 5%, between the segment left and right areas; 3) The variation of the area index about five groups there is not a statically significant that couldn’t use of the both method to build the complete denture. Although, more studies are important to realize with the objective to improve the use the microwave over to process the denture.

Page generated in 0.0661 seconds