• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • Tagged with
  • 59
  • 59
  • 52
  • 46
  • 45
  • 20
  • 18
  • 17
  • 16
  • 15
  • 15
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise por microtomografia computadorizada do preparo e obturação de canais radiculares achatados de segundos pré-molares superiores /

Tavares, Karina Ines Medina Carita. January 2020 (has links)
Orientador: Mario Tanomaru Filho / Resumo: Objetivo: Avaliar o preparo empregando dois sistemas rotatórios de níquel-titânio tratados termicamente e efeito do novo inserto ultrassônico e instrumento de menor diâmetro e a capacidade de preenchimento dos cimentos Bio-C Sealer ou AH Plus pela técnica de cone único em canais radiculares achatados de segundos pré-molares superiores. Metodologia: Canais radiculares achatados de segundos pré-molares superiores humanos com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados com sistemas rotatórios(n=16): ProDesign Logic (PDL) 30.01 e 30.05 ou HyFlex EDM (HEDM) 10.05 e 25.08. Etapa do preparo complementar foi realizada com inserto ultrassônico Flatsonic (terço cervical e médio) e PDL 25.03 (terço apical) (FPDL) em ambos os grupos. Os canais radiculares foram obturados (n=16) com o cimento Bio-C Sealer ou AH Plus pela técnica de cone único. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Os testes estatísticos específicos para o preparo e obturação foram realizados com nível de significância de 5%. Publicação 1 – Resultados: Não houve diferença estatística entre PDL e HEDM para o aumento de volume, debris e superfície não instrumentada no canal como um todo (P>0,05). PDL obteve maior percentual... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to evaluate root canal preparation using two rotary nickel-titanium systems thermally treated and the effect of ultrasonic tip and small diameter instrument; and the filling capacity of sealers Bio-C Sealer and AH Plus by single cone technique in flattened root canals of maxillary second premolars. Methods: Flattened root canals of human maxillary second premolars with buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with rotary systems (n=16): ProDesign Logic (PDL) 30.01 e 30.05 or HyFlex EDM (HEDM) 10.05 e 25.08. Complementary preparation step was performed with ultrasonic tip Flatsonic (cervical and middle thirds) and PDL 25.03 (apical third) (FPDL) in both groups. The root canals were filled (n=16) with Bio-C Sealer or AH Plus by single cone technique. Scanning in resolution of 8,74 µm were performed by microcomputed tomography (micro-CT) before and after the experimental steps. Percentage of increase in volume, debris and uninstrumented surface were analysed for the preparation steps and percentage of voids for obturation. The statistical tests specific to preparation and obturation analyses were performed with a significance level of 5%. Publication 1 - Results: There was no statistically difference between PDL and HEDM for volume increase, debris and uninstrumented surface, in entire canal (P>0,05). PDL showed higher debris in the middle and apical thirds than HEDM (P<0,05). The FPDL protocol ... (Complete abstract click electronic access below) / Mestre
32

Determinação da área alargada posterior ao retratamento do canal radicular com instrumentos de níquel-titânio / Determination of the enlarged area after retreatment of the root canal with nickel-titanium instruments.

Pereira, Larissa Ernesto 27 July 2018 (has links)
O objetivo do presente estudo foi determinar a área alargada posterior ao retratamento do canal radicular com instrumentos de níquel-titânio em imagens de tomografia computadorizada de feixe cônico. Sessenta raízes mesiais de molares inferiores foram selecionadas e submetidas a tomografia computadorizada de feixe cônico(TCFC) em 4 períodos de: antes do preparo (T1), após o preparo (T2), após o retratamento (T3) e após a complementação do retratamento (T4). Após a TCFC inicial (T1), os dentes foram submetidos ao protocolo de abertura coronária e exploração dos canais com lima manual tipo K n.15, preparados com instrumentos ProTaper Next (até X3: # 30.07), e submetidos novamente a TCFC (T2); A seguir foram obturados pela técnica híbrida de Tagger com cimento AH Plus, e submetidos a 1000 ciclos de termociclagem simulando um período de 12 meses. Subsequentemente, os espécimes foram distribuídos de acordo com os protocolos de desobturação do canal radicular, em três grupos (n=10): G1- Protaper Universal Retratamento (D1: #30.09; D2: #25.08; D3: #20.07;); G2- Mtwo Retratamento (#25.05) e G3- DRaCe (DR1: #30.10; DR2: #25.04). Após a desobturação, os espécimes foram submetidos novamente à TCFC (T3). Em seguida, foram submetidos ao protocolo de complementação para remoção do material obturador, em três grupos (n=10): G1, G2 e G3: PT next X4: #40.06. A seguir os espécimes foram submetidos novamente à TCFC (T4) para avaliação da área alargada do canal radicular. A média e o desvio padrão das variáveis quantitativas foram obtidas. A normalidade dos dados foi avaliada pelo teste de Kolmogorov-Smirnov. As variáveis foram avaliadas pelo Teste-t para amostras pareadas para avaliar a diferença entre a área desgastada entre o preparo (Tomografia 2) e o retratamento (Tomografia 4). As variáveis foram avaliadas pelo Teste de Análise de Variância (ANOVA) post hoc Tukey para a comparação entre Protaper-R (grupo 1), Mtwo-R (grupo 2) e D- Race (grupo 3). Foram considerados significativos valores de p < 0,05. A análise de variância evidenciou diferença estatisticamente significante em relação aos grupos em canal mesiovestibular em nível 2 mm abaixo de furca p<0,038 e em canal mesiovestibular em nível 4 mm abaixo de furca p<0,005. Evidenciou também diferença estatisticamente significante em relação aos grupos 1, 2 e 3 em canal mesiovestibular em nível 2 mm abaixo de furca após o retratamento p<0,028. A diferença média da área alargada entre o preparo e o retratamento em canais mesiovestibulares comparando os grupos Protaper-R, Mtwo-R e D-race evidenciou diferença estatisticamente significante em todos os grupos (p<0,000 e p<0,029) e em canais mesiolinguais valores entre p<0,000 e p<0,029. Conclui-se que as técnicas de complementação avaliadas aumentaram a área do canal radicular, contribuindo para a remoção do remanescente de material obturador, sendo que o sistema Protaper-R ® permitiu maior desgaste. Embora tenha havido ampliação da área do canal radicular em níveis determinados, nenhuma das técnicas avaliadas foram capazes de remover completamente o material obturador dos canais radiculares / The objective of the present study was to determine the enlarged area after retreatment of the root canal with nickel-titanium instruments in conical beam computed tomography images. Sixty mesial roots of mandibular molars were selected and submitted to concomitant computed tomography (CBCT) in 4 periods of: before preparation (T1), after preparation (T2), after retreatment (T3) and after completing retreatment (T4). After the initial CBCT (T1), the teeth were submitted to the protocol of coronary opening and exploration of channels with manual file type K n.15, prepared with ProTaper Next instruments (up to X3: # 30.07), and again submitted to CBCT); They were then filled by the Tagger hybrid technique with AH Plus cement and submitted to 1000 cycles of thermocycling simulating a period of 12 months. Subsequently, the specimens were distributed according to root canal clearance protocols, in three groups (n = 10): G1 Protaper Universal Retreatment (D1: # 30.09; D2: # 25.08; D3: # 20.07;); G2- Mtwo Retreatment (# 25.05) and G3- DRaCe (DR1: # 30.10; DR2: # 25.04). After disintegration, the specimens were again submitted to TCFC (T3). Afterwards, they were submitted to the complementation protocol to remove the obturator material, in three groups (n = 10): G1, G2 and G3: PT next X4: # 40.06. Afterwards the specimens were again submitted to TCFC (T4) for evaluation of the enlarged area of the root canal. The mean and standard deviation of the quantitative variables were obtained. The normality of the data was evaluated by the Kolmogorov-Smirnov test. The variables were evaluated by the t-Test for paired samples to evaluate the difference between the worn area between the preparation (Tomography 2) and the retreatment (Tomography 4). The variables were evaluated by the Tukey post-hoc ANOVA for the comparison between Protaper- R (group 1), Mtwo-R (group 2) and D-Race (group 3). Values of p <0.05 were considered significant. The analysis of variance showed a statistically significant difference in relation to the groups in mesiobuccal channel at level 2 mm below furca p <0.038 and in mesiobuccal channel at level 4 mm below furca p <0.005. There was also a statistically significant difference in relation to groups 1, 2 and 3 in mesiobuccal channel at level 2 mm below furcation after retreatment p <0.028. The mean difference in the wide area between preparation and retreatment in mesiobuccal canals comparing the Protaper-R, Mtwo-R and D-race groups showed a statistically significant difference in all groups (p <0.000 and p <0.029) and in mesiolinguistic channels values between p <0.000 and p <0.029. It was concluded that the complementation techniques evaluated increased the root canal area, contributing to the removal of the remainder of the obturator material, and the Protaper-R ® system allowed for greater wear. Although there was enlargement of the root canal area at determined levels, none of the techniques evaluated were able to completely remove the obturator material from the root canals
33

Avaliação do preparo de canais radiculares com instrumentos rotatórios torcidos e usinados, por meio de cortes transversais e da microtomografia computadorizada / Evaluation of root canal preparation with rotary instruments twisted and ground by means of cross sections and microcomputed tomography

Freire, Laila Gonzales 02 August 2010 (has links)
O preparo químico-cirúrgico é uma das etapas mais importantes do tratamento endodôntico, pois promove a desinfecção do sistema de canais radiculares através da limpeza e da modelagem. Realizar o preparo de canais curvos é um grande desafio, devido à ocorrência freqüente de acidentes operatórios como o transporte do canal. A introdução de instrumentos fabricados em ligas de níquel-titânio (NiTi) contribuiu consideravelmente para a melhora na qualidade da instrumentação dos canais. Os diferentes sistemas rotatórios que são apresentados continuamente ao profissional devem ser estudados com detalhes, pois o seu comportamento pode variar de acordo com o desenho de cada instrumento e as suas características de produção. O objetivo deste estudo foi avaliar, ex vivo, a qualidade do preparo de canais curvos realizado pelos sistemas rotatórios Twisted File (TF; Sybron Endo), torcidos, e EndoSequence (ES; Brasseler), usinados, quanto à habilidade em manter o canal centralizado, analisando a extensão e a direção dos eventuais transportes e o índice de centralização do instrumento (IC), por meio de cortes transversais e da microtomografia computadorizada (CT). Trinta molares inferiores foram divididos em dois grupos, e preparados conforme o delineamento de cada método: G1 - Bramante Modificado e G2 - CT. No G1, os dentes foram incluídos em blocos de resina, e seccionados a 2,0, 3,5 e 5,0 mm do ápice radicular. As secções foram fotografadas, e os blocos, remontados, foram submetidos à instrumentação rotatória. No G2, os dentes foram incluídos em material de moldagem e escaneados com um microtomógrafo, antes e após o preparo. As imagens das seções transversais foram reconstruídas e os cortes axiais correspondentes às distâncias de 2,0, 3,5 e 5,0 mm do ápice radicular foram selecionados. Os resultados foram submetidos ao teste estatístico não-paramétrico Mann-Whitney, para comparações duas a duas. Em ambos os grupos, o transporte do canal e o IC para os sistemas TF e ES foram semelhantes, havendo diferença estatística significante apenas no G2, na secção 3,5 mm, quando o sistema TF causou menos transporte do que o sistema ES, obtendo também um melhor IC (p < 0,05). Quando realizada a comparação entre os métodos, independentemente do instrumento utilizado, o transporte do canal foi significantemente menor (0,17 mm) no grupo 2, do que no grupo 1 (0,27 mm) (p < 0,05). A 3,5 e 5,0 mm, o sistema TF promoveu menos transporte no grupo 2 do que no grupo 1 (p < 0,05). Para o sistema ES, diferença estatística foi encontrada a 2,0 mm, aonde o transporte também foi menor no grupo 2 (p < 0,05). Concluiu-se que os sistemas TF e ES se comportaram de modo semelhante quanto ao transporte do canal e ao IC, permitindo o preparo de canais curvos com pouco desvio. Os dois instrumentos apresentaram desvios tanto para o sentido mesial, quanto para o sentido distal. E quando comparados apenas os métodos de avaliação, no método da CT o transporte do canal foi menor do que no método de Bramante Modificado. / The chemomechanical preparation is one of the most important phases of endodontic treatment, because it promotes disinfection of the root canal system by cleaning and shaping. The preparation of curved canals is a major challenge due to the frequent occurrence of operative accidents as the canal transportation. The introduction of instruments of nickel-titanium (NiTi) alloy has contributed considerably to the improvement of canal instrumentation quality. The different rotary systems that are continuously presented to dental professionals should be studied in detail, because their mechanical properties can vary according to the design of each instrument and the manufacture characteristics. The aim of this study was to evaluate, ex vivo, the quality of preparation of curved canals and centering ability of the rotary systems Twisted File (TF) (Sybron Endo), twisted, and EndoSequence (ES) (Brasseler), ground, analyzing the extent and direction of any transportation and the centering ratio of instrument, by cross sections and microcomputed tomography (CT). Thirty lower molars were divided into two groups, and prepared according to the design of each method: G1 Bramante Modified and G2 - CT. In G1, the teeth were embedded in resin blocks and sectioned at 2,0, 3,5 and 5,0 mm from the apex. The sections were photographed and the blocks were reassembled and subjected to rotary instrumentation. In G2, the teeth were embedded in an impression material and scanned with a microtomograph, before and after preparation. The images were reconstructed from the cross sections and the axial sections corresponding to distances of 2,0, 3,5 and 5,0 mm from the apex were selected. The results were submitted to statistical nonparametric test Mann-Whitney. In both groups, the canal transportation and IC for TF and ES systems were similar, with statistical difference only for the 3.5 mm section, while TF system caused less canal transportation than ES system, obtaining also better IC (p <0.05). When compared only the methods, regardless of instrument used, the canal transportation was significantly smaller (0.17 mm) in group 2 than in group 1 (0.27 mm) (p <0.05). At 3.5 and 5.0 mm, TF system promoted less transportation in group 2 than in group 1 (p <0.05). For ES system, statistical difference was found at 2.0 mm, where transportation was also lower in group 2 (p <0.05). It was concluded that the systems TF and ES behaved similarly about the canal transportation and the centering ability, allowing the preparation of curved canals with little deviation. The two instruments showed deviations for both the mesial and distal direction. When comparing only the methods of assessment, at CT the canal transportation was lower than in Bramante Modified method.
34

Efetividade de diferentes sistemas de preparo do canal radicular na eliminação de Enterococcus faecalis / Effectiveness of diferente root canal preparation systems against Enterococcus faecalis

Leonardo, Mario Francisco de Pasquali 08 August 2012 (has links)
O objetivo deste estudo consiste em avaliar a efetividade de diferentes sistemas empregados no preparo biomecânico, dentre eles: Self-adjusting file (SAF), TiLOS Anatomic Endodontic Technology System (TiLOS) e Mtwo sobre a eliminação de Enterococcus faecalis cultivados em canais radiculares. Para isso, foram selecionados 47 prés-molares inferiores humanos, os quais foram contaminados por Enterococcus faecalis (ATCC 29212) durante 21 dias e divididos em três grupos: GI - SAF com irrigação contínua; GII - EndoEze Tilos e irrigação com auxílio de agulhas NaviTip; GIII - MTwo e irrigação com NaviTip a cada troca de instrumento. A irrigação foi realizada com solução de NaOCl a 2,5%. Coletas bacterianas foram realizadas em três tempos experimentais: coleta da contaminação (S1), posterior ao preparo dos canais radiculares (S2) e após sete dias do preparo biomecânico (S3). Os dados em UFC foram submetidos aos testes ANOVA e Tukey ou Kruskal-Wallis e Dunn com P<0.05. Na análise dos resultados, foi observada redução de E.faecalis após preparo (P < .05) em todos os grupos, sem diferença significante entre os grupos (P > .05). A coleta final demonstrou aumento bacteriano similar em todos os grupos, esclarecendo a viabilidade das bactérias incubadas. Dessa forma, conclui-se que o preparo dos canais radiculares realizado com SAF, EndoEze Tilos e Mtwo contribuem na desinfecção do canal radicular, sem, todavia, eliminar o E. faecalis do sistema de canais radiculares. / The aim of this study was to evaluate the effectiveness of different chemo-mechanical systems for root canal preparation Self-adjusting File (SAF), TiLOS Anatomic Endodontic Technology System (TiLOS), and Mtwo against Enterococcus faecalis in the canal. Forty seven human mandibular bicuspids were contaminated with E. faecalis (ATCC 29212) for 21 days and divided into groups according to preparation methodÇ SAF group with continuous irrigationç TiLOS;Endo-Eze group and irrigation with a NaviTip needle Mtwo group and irrigation eith NaviTip. The irrigant used was 2.5% NaOCl. Bacterial harvests were performed after the contamination period (initial harvest), immediately post-preparation, and seven days after chemo-mechanical preparation. Data were expressed as CFU and subjected to ANOVA and Tukey or Kruskal-Wallis and Dunn tests at P < 0.05. Reduction in E.faecalis was observed after preparation (P< .05), with no significant differences between the groups (P> .05). The final harvest demonstrated statistically similar increase in the bacterial counts in all groups. Root canal preparation using SAF, TiLOS;Endo-Eze, and Mtwo systems contribute for the disinfection of the root
35

Avaliação da citotoxicidade e da genotoxicidade da mistura da clorexidina com hipoclorito de sódio sobre diferentes linhagens celulares / Evaluation of the Interaction between Sodium Hypochlorite and Chlorhexidine Gluconate and its Effect on Cytotoxicity and Genotoxicity of cell cultures

Azambuja Junior, Nilton 14 September 2012 (has links)
O uso de irrigação com solução de hipoclorito de sódio a 1% (NaOCl) seguida de irrigação final com solução de clorexidina a 2%(CHX) pode promover uma melhor antissepsia do sistema de canais radiculares do que as abordagens tradicionais. Já foi relatado que estas substâncias quando entram em contato dentro do sistema de canais radiculares produzem subprodutos a partir de sua mistura, que apresentam uma fase líquida e uma fase sólida precipitada que permanece nas paredes do canal radicular. Sua ação citotóxica em cultura de células ainda não foi estudada. O objetivo deste estudo foi avaliar o efeito desta mistura e seus subprodutos in vitro sobre a viabilidade celular. Para avaliar se o grau de diferenciação pode afetar a sobrevivência celular foram escolhidas para o experimento fibroblastos de gengiva humana (FMM1) que são células mais diferenciadas e células-tronco de polpa dentária humana (PDH3) menos diferenciadas. Métodos: partes iguais de soluções de hipoclorito 1% (NaOCl) e digluconato de clorexidina 2% (CHX) foram misturadas e os subprodutos obtidos. Os grupos experimentais testados foram: G1- CHX, G2- NaOCl + CHX(fase líquida), G3- NaOCl + CHX(fase sólida). Quatro(4) diferentes concentrações (100%, 1%, 0,5% e 0,25%) das substâncias de G1 e G2 e do meio de cultivo condicionado pelo G3, foram aplicadas às culturas de células. A viabilidade celular foi mensurada pelo teste de redução do MTT (n=24/concentração/substância/células) e a genotoxicidade através de contagem de micronúcleos apenas para as concentrações das substâncias de 0,5% e 0,25% (número de micronúcleos/1000 células em cada contagem, 2 contagens), ambos em 24 horas após o contato de 15 minutos com as substâncias testadas. Os dados foram analisados por ANOVA complementado por teste de Tukey(p<0,05) para o MTT e qui-quadrado para genotoxicidade. Como resultados da viabilidade celular a dose letal de 50%(DL50) ocorreu apenas nas concentrações menores que 5% no G1, e ao redor de 1% para G2 e G3. Como resultados do teste de genotoxicidade os mesmos números de micronúcleos foram encontrados para todos os grupos em duas contagens de 1000 células. As células PDH3 apresentaram maior viabilidade que a FMM1 com maior número de células em concentrações maiores das substâncias testadas, demonstrando maior resistência de células menos diferenciadas. Como não houve diferença estatística no número de micronúcleos entre os grupos do teste de genotoxicidade inferimos que não houve aumento do número de micronúcleos entre os grupos de teste e o controle. Portanto, a solução de CHX a 2% quando aplicada sobre as células em cultura in vitro não foi biocompatível em concentrações de diluição acima de 0,5%; não foi genotóxica, pois não houve aumento na formação de micronúcleos nem com o grupo da clorexidina nem com a fase líquida da mistura ou com o precipitado. / New antimicrobial therapies have been introduced in Endodontics for periapical lesions and treatment-resistant infections. Alternating irrigating solutions such as 1% sodium hypochlorite (NaOCl) solution and 2% chlorhexidine (CHX) solution has shown promising results. However, inside the root canal system the NaOCl and CHX interact producing byproducts (Bps) represented by a liquid (Liq) and a solid precipitated (Sol) that remain on the canal walls. Objectives: To study the cytotoxicity of such Bps and CHX using cultured fibroblasts (FMM1) and stem cells(PDH3). Two cell lines were chosen to test if different differentiated cell types would present different survival results. Methods: Equal parts of 1% NaOCL and 2% CHX solutions were mixed and the Bps were obtained. Three drug solutions were tested: cell culture medium dilution of CHX, cell culture medium dilution of Liq and cell culture medium conditioned by the Sol byproduct. They were prepared in fresh medium in 4 different concentrations (100%, 1%, 0,5%, 0,25%) and applied to the cells for 15 minutes. In the control wells the cells grew on fresh medium. Cytotoxicity was measured by using the MTT reduction assay in 24 replicates per concentration per solution. Twenty-four hours later cell viability was analyzed. Micronucleus counting was used to check genotoxicity (number of micronucleus/ 1000 cell, 2 counting). Data was evaluated through ANOVA test with post hoc Tukey(p<0,05) for MTT assay and qui-square for genotoxicity. Lethal dose concentration 50%(LD50) was obtained in concentrations less than 0,5% with CHX and around 1% for Liq and Sol. there were obtained same number of micronucleous for all the substances tested. PDH3 cells presented higher survival rate to higher concentrations, so they were more resistant than FMM1. There was no statistical difference between control and tested groups for genotoxicity. 2% CHX solution when applied to cell cultures was not biocompatible in concentrations above 0,5%; there is no increase in micronucleous number with tested substances.
36

Incid?ncia cl?nica de fratura de limas endod?nticas de n?quel-tit?nio acionadas em cinem?tica rotat?ria cont?nua versus cinem?tica reciprocante : uma revis?o sistem?tica e meta-regress?o

Vieira, Ros?ngela Mello 18 January 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-03-09T17:05:54Z No. of bitstreams: 1 ROSANGELA_MELLO_VIEIRA_DIS.pdf: 2509683 bytes, checksum: 029b2e55766a406fa01c070281169016 (MD5) / Approved for entry into archive by Tatiana Lopes (tatiana.lopes@pucrs.br) on 2018-03-14T12:03:02Z (GMT) No. of bitstreams: 1 ROSANGELA_MELLO_VIEIRA_DIS.pdf: 2509683 bytes, checksum: 029b2e55766a406fa01c070281169016 (MD5) / Made available in DSpace on 2018-03-14T12:12:44Z (GMT). No. of bitstreams: 1 ROSANGELA_MELLO_VIEIRA_DIS.pdf: 2509683 bytes, checksum: 029b2e55766a406fa01c070281169016 (MD5) Previous issue date: 2018-01-18 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Introduction: The fracture of nickel titanium endodontic instruments may have a negative impact on the prognosis of the treatment, mainly because it blocks or prevents access to the root canal system in all its extension, compromising its modeling and sanification. Results from in vitro studies suggest that reciprocating motion can reduce the risks of torsion fracture and cyclic fatigue of NiTi instruments, compared to the continuous rotation movement. However, most of the studies that evaluate fracture resistance of instruments in reciprocating and rotational motion are in vitro studies, the generation of evidence of which is limited in comparison to the level of evidence generated by clinical studies in humans. Therefore, the present systematic review investigated whether the available evidence supports the hypothesis that reciprocating motion results in a lower clinical incidence of NiTi limb fracture as compared to rotational kinematics. Methodology: The PubMed, Embase, Isi Web of Science and Cochrane Library databases were searched until August 2017, without language restriction. In addition to the electronic searches, manual searches were made for additional references in specific chapters of relevant books in the area and also search in the gray literature. Based on the inclusion and exclusion criteria, two reviewers independently assessed the quality of each study based on the NewCastle Ottawa scale. The main exposure variable was the type of kinematics used to prepare the root canal (continuous or reciprocating) and the primary outcome variable was determined by the incidence of fracture of NiTi instruments in endodontic treatments. The incidence of fracture was recorded, having as unit of analysis: patients, teeth, instruments or channels. Other confounding variables collected included: country, year of publication, study design, type of system, group of teeth, number of sessions, operator and number of uses of NiTi instruments. The sources of heterogeneity were explored and the bi and multivariate meta logistic regression were performed to calculate the pooled estimates - odds ratios (OR) and 95% CI - for the incidence of instrument fracture, assessing the role of primary exposure and co- as moderators of the outcome. Results: Among the 737 articles initially identified, after the duplicates were removed, 39 comprised the final quantitative analysis, of which 32 reported the use of continuous rotation and 7 the use of reciprocating kinematics. Thirty-seven studies were included in the meta regression (N = 48,405 instruments). The aggregate clinical incidence of fracture of NiTi files was 2.43%, being 2.62% for continuous rotational movement and 0.4% for reciprocating kinematics. In the bivariate analysis, continuous rotational motion showed a greater incidence of fracture in relation to the reciprocating kinematics (OR = 6.39, 95% CI = 1.10-36.9), and the other associated covariates (p <0.05) with the incidence of fracture were: year of publication, operator and number of uses of the instruments. The multivariate models revealed that the number of uses of NiTi files in> 1 tooth (OR = 6.46, 95% CI = 1.42-29.3) and that general clinical operators (OR = 11.8, 95% CI = 1.49-93.5) were independently associated with a higher incidence of fracture of NiTi files, whereas kinematics was non-significant (OR = 1.56, 95% CI= 0.24-10, 0) after the settings. Conclusions: Available evidence from observational studies is limited but consistent, suggesting that reciprocating kinematics is associated with a lower incidence of fracture of NiTi files when compared to continuous rotation. In addition, the results revealed that other related clinical factors to the abilities of the operator,to the number of uses of the NiTi instruments, and to the advances in alloy composition as well as in the design of the files, have proved to be more relevant factors for fracture prevention than the type of kinematics employed. / Introdu??o: A fratura de instrumentos endod?nticos de n?quel tit?nio pode ter um impacto negativo no progn?stico do tratamento, sobretudo por bloquear ou impedir o acesso ao sistema de canais radiculares em toda sua extens?o, comprometendo a sua modelagem e sanifica??o. Resultados de estudos in vitro sugerem que o movimento reciprocante pode reduzir os riscos de fratura por tors?o e fadiga c?clica dos instrumentos de NiTi, comparado ao movimento de rota??o cont?nua. Ainda assim, a maioria dos estudos que avaliam a resist?ncia ? fratura de instrumentos no movimento reciprocante e rotat?rio s?o estudos in vitro, cuja gera??o de evid?ncias ? limitada em compara??o ao n?vel de evid?ncia gerada por estudos cl?nicos em humanos. Portanto, a presente revis?o sistem?tica investigou se a evid?ncia dispon?vel suporta a hip?tese de que o movimento reciprocante resulta em uma menor incid?ncia cl?nica de fratura de limas de NiTi, em compara??o com a cinem?tica rotat?ria. Metodologia: Foram pesquisadas as bases de dados PubMed, Embase, Isi Web of Science e Cochrane Library at? agosto de 2017, sem restri??o de idiomas. Al?m das buscas eletr?nicas foram realizadas buscas manuais por refer?ncias adicionais em cap?tulos espec?ficos de livros relevantes na ?rea e tamb?m busca na literatura cinza. Com base nos crit?rios de inclus?o e exclus?o, dois revisores avaliaram independentemente a qualidade de cada estudo com base na escala de NewCastle Ottawa. A principal vari?vel de exposi??o foi o tipo de cinem?tica empregada para o preparo do canal radicular (rotat?ria cont?nua ou reciprocante) e a vari?vel de desfecho prim?rio foi determinada pela incid?ncia de fratura de instrumentos de NiTi em tratamentos endod?nticos. A incid?ncia de fratura foi registrada, tendo como unidade de an?lise: pacientes, dentes, instrumentos ou canais. Outras vari?veis de confundimento coletadas incluiram: pa?s, ano de publica??o, desenho do estudo, tipo de sistema, grupo de dentes, n?mero de sess?es, operador e n?mero de usos dos instrumentos de NiTi. As fontes de heterogeneidade foram exploradas e a meta regress?o log?stica bi e multivariada foram realizadas para calcular as estimativas agrupadas ? odds ratios (OR) e 95%IC ? para a incid?ncia de fratura de instrumentos, avaliando o papel da exposi??o principal e das co-vari?veis, como moderadores do desfecho. Resultados: Entre os 737 artigos inicialmente identificados, ap?s remo??o das duplicatas, 39 compuseram a an?lise quantitativa final, dos quais 32 reportavam o uso de rota??o cont?nua e 7 o uso de cinem?tica reciprocante. Trinta e sete estudos foram inclu?dos na meta regress?o (N=48.405 instrumentos). A incid?ncia cl?nica agregada de fratura de limas de NiTi foi de 2,43%, sendo de 2,62% para o movimento rotat?rio cont?nuo e de 0,4% para a cinem?tica reciprocante. Na an?lise bivariada, o movimento rotat?rio cont?nuo demonstrou uma incid?ncia maior de fratura em rela??o ? cinem?tica reciprocante (OR=6,39, IC95%=1,10- 36,9), e as outras covari?veis associadas (p<0,05) com a incid?ncia de fratura foram: ano de publica??o, operador e n?mero de usos dos instrumentos. Os modelos multivariados revelaram que o n?mero de usos de limas de NiTi em >1 dente (OR=6,46, IC95%=1,42-29,3) e que operadores cl?nicos gerais (OR=11,8, IC95%=1,49-93,5) foram associados de modo independente com uma maior incid?ncia de fratura de limas de NiTi, enquanto que a cinem?tica demonstrou-se n?o-significante (OR=1,56, IC95%=0,24-10,0) ap?s os ajustes. Conclus?es: A evid?ncia dispon?vel, oriunda de estudos observacionais, ? limitada por?m consistente, sugerindo que a cinem?tica reciprocante est? associada com uma menor incid?ncia de fratura de limas de NiTi, quando comparada ao movimento de rota??o cont?nua. Al?m disso, os resultados revelaram que outros fatores cl?nicos relacionados ?s habilidades do operador, ao n?mero de usos dos instrumentos de NiTi, e aos avan?os na composi??o das ligas bem como no desenho das limas, demonstraram ser fatores mais relevantes para a preven??o da fratura do que o tipo de cinem?tica empregada.
37

Análise multidimensional do preparo de canais radiculares curvos com instrumentos de níquel-titânio em rotação contínua e reciprocante / Multidimensional analysis of curved root canal preparation using continuous or reciprocating nickel-titanium instruments

Mamede Neto, Iussif 18 November 2016 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-01-04T09:35:23Z No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-04T09:59:04Z (GMT) No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-04T09:59:04Z (GMT). No. of bitstreams: 2 Tese - Iussif Mamede Neto - 2016.pdf: 8414229 bytes, checksum: dbd825fbd28378443533fac54c7a09c1 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-11-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Objective: To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Material and methods: Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divide into 6 groups (n=16) according to the rotary file used: Group 1- ProTaper Next®; Group 2- ProTaper Gold®; Group 3- Mtwo®; Group 4- BioRaCe®; Group 5- WaveOne Gold®; Group 6- Reciproc®. Root canals were prepared according to manufacturer’s instructions. Cone-beam computed tomography scans were obtained before and after canal preparation. Measurements were made at five different points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation. Transportation and centering ability were analyzed following the recommendations made by Gambill et al. (1996). Results: The greatest mesiodistal (MD) transportation (T) was found for Reciproc® files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc®, ProTaper Gold® and ProTaper Next® files (p<0.05). The greatest mesiodistal (MD) centering ability (CA) was found for BioRaCe® files (p<0.05), and the greatest buccolingual (BL) CA, for BioRaCe® and Mtwo® files (p<0.05). Conclusion: All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc® files had the greatest MD T and BL T. BioRaCe® files had the greatest MD CA, whereas BL CA was similar for BioRaCe® and Mtwo® files. / Objetivo: Avaliar o índice de transporte (IT) e a capacidade de centralização (CC) do preparo do canal radicular com instrumentos endodônticos de níquel-titânio acionados em rotação contínua e reciprocante. Materiais e métodos: Noventa e seis canais mesiovestibulares de molares inferiores (primeiro e segundo) foram aleatoriamente divididos em 06 grupos (n=16), de acordo com o instrumento rotatório utilizado: Grupo 1- ProTaper Next®; Grupo 2- ProTaper Gold®; Grupo 3- Mtwo®; Grupo 4- BioRaCe®; Grupo 5- WaveOne Gold®; Grupo 6- Reciproc®. A técnica de preparo do canal radicular obedeceu a orientação dos fabricantes. Tomografia computadorizada de feixe cônico foi realizada antes e após o preparo dos canais radiculares. Foram estabelecidos 06 níveis para a realização das mensurações nas imagens: 2, 3 e 4 mm aquém do vértice radicular e 2, 3 e 4 mm abaixo da furca. O índice de transporte e a capacidade de centralização foram analizados conforme proposto por Gambill et al. (1996). Resultados: O maior IT no sentido mesiodistal (MD) foi observado com o Reciproc® (p<0,05), enquanto que no sentido vestíbulolingual (VL) foram verificados com Reciproc®, ProTaper Gold® e ProTaper Next® (p<0,05). Os maiores valores de CC(MD) e (VL) foram observados com os sistemas BioRaCe® (p<0,05) e BioRaCe® e Mtwo® (p<0,05), respectivamente. Conclusão: Todos os sistemas promoveram transporte do canal radicular. Nenhum instrumento mostrou capacidade de centralização do preparo perfeita. O Reciproc® obteve os valores maiores de IT(MD) e (VL). O sistema BioRaCe® apresentou a maior CC(MD), enquanto que no sentido (VL) o BioRaCe® e Mtwo® mostraram capacidades similares.
38

Avaliação microtomográfica de canais mesiais de molares inferiores preparados com sistemas rotatórios e reciprocantes / Computed microtomography analysis of mesial canals of mandibular molars prepared with rotary and reciprocating systems

Marília Fagury Videira Marceliano Alves 12 September 2013 (has links)
O objetivo do presente trabalho foi avaliar, em microtomografia computadorizada (CT), o preparo de canais de molares inferiores com diferentes sistemas acionados a motor. Foram selecionadas 58 raízes mesiais patentes, de diâmetro anatômico correspondente a #10. Para a avaliação em TC, um anel de aço inoxidável foi confeccionado nos moldes do suporte para amostra do microtomógrafo, para que servisse de fôrma para a inclusão das raízes em resina Duralay, a fim de padronizar a posição do espécime no escaneamento inicial e final. Os canais foram preparados com os sistemas Reciproc R25 (n=16); WaveOne Primary File (n=16); Twisted File (n=14), e HyFlex (n=12). Após serem escaneados, foram reconstruídos tridimensionalmente e avaliados quantitativamente quanto à variação de volume (mm3), área de superfície (mm2) e structure model index (SMI). Foi, ainda, realizada a avaliação qualitativa das seções transversais por terço e por quadrante (MV, ML, DV, DL), sendo avaliado o toque de paredes. Os dados paramétricos foram analisados estatisticamente pelos testes ANOVA e t para amostras pareadas (&#945;=5%). Não foi observada diferença estatística nos parâmetros quantitativos avaliados para Reciproc (142,77 76,75; 42,22 19,22; e 14,68 17,69, respectivamente); WaveOne (105,09 64,82; 29,54 19,21; 14,81 9,10, respectivamente); Twisted File (111,83 43,09; 33,31 18,40; 9,16 6,57, respectivamente), e HyFlex (151,74 149,37; 43,08 41,44; 10,80 8,52, respectivamente) (p=0,423). Dentro de cada grupo, foi observada diferença significante entre os resultados pré e pós-operatórios. O teste não paramétrico de Kruskal Wallis foi aplicado para a avaliação relativa ao toque de paredes. Foi observado que o sistema HyFlex apresentou a maior porcentagem de toques (82,3 13,1), seguido por Reciproc (81,3 16,9), Twisted File (78,3 14,4) e, por fim, WaveOne (76,9 21,7) (p>0,05). Em relação aos terços não foi observada diferença significativa (p=0,424). Os resultados da avaliação dos quadrantes intergrupo não demonstraram diferenças, porém indicaram tendência do preparo em direção à parede distal no terço cervical. Ao final, pôde-se concluir que os sistemas testados se equivalem quanto ao preparo de canais mesiais de molares inferiores; porém, nenhuma das técnicas foi capaz de tocar completamente em todas as paredes do canal radicular. / The aim of this work was to analyze, in X-ray computed microtomography (CT), the root canal preparation of mandibular molars with different engine driven systems. 58 mesial roots were selected, of anatomic diameter corresponding to #10. For the analysis in TC, a stainless steel ring was manufactured in the same shape as the brace for CT sampling, in order to serve as a mold to insert the roots in Duralay resin, so as to standardize the position of the specimen in the initial and final scanning. The canals were prepared with the Reciproc R25 (n=16), WaveOne Primary File (n=16), Twisted File (n=14) and HyFlex (n=12) systems. After being scanned, they were three-dimensionally reconstructed and quantitatively evaluated as regards the variation of volume (mm3), surface area (mm2) and structure model index (SMI). In addition, the qualitative evaluation of the cross sections by third and by quadrant (MV, ML, DV, DL) was carried out, along with the wall touching evaluation. The parametric data were statistically analyzed by ANOVA and t-tests for paired samples (&#945;=5%). No statistical difference was observed in the qualitative parameters evaluated for Reciproc (142.77 76.75; 42.22 19.22; and 14.68 17.69; respectively), WaveOne (105.09 64.82; 29.54 19.21; 14.81 9.10; respectively), Twisted File (111.83 43.09; 33.31 18.40; 9.16 6.57; respectively) and HyFlex (151.74 149.37; 43.08 41.44; 10.80 8.52) (p=0,423). Significant difference was observed within each group between the pre- and post-results. The Kruskal-Wallis non-parametric test was applied for the evaluation as regards root canal wall touching. At the end, we observed that the HyFlex system presented the highest touching rate (82.3 13.1), followed by the Reciproc (81.3 16.9), Twisted File (78.3 14.4) and, finally, WaveOne (76.9 21.7) systems (p>0.05). As for the thirds, was not observed any significant difference (p=0.424). The results of the evaluation in the intergroup quadrants did not show any difference; however, they showed that there was a preparation trend towards the distal wall in the cervical third. At the end, it can conclude that the systems tested are equivalent as regards the preparation of mesial canals of mandibular molars, but none of the techniques was capable of fully touching all root canal walls.
39

Influência da espessura do filme de cimento na resistência adesiva de pinos de fibra de vidro cimentados em condutos radiculares de dentes humanos / Influence of the cement film thickness on the push out bond strength of glass fiber posts cemented in human root canals

Natália Araújo Silva Prado 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo visa avaliar a influência da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro em diferentes regiões do conduto radicular (cervical, médio e apical), cimentados com cimento resinoso autoadesivo, com e sem a adição de Rodamina B, por meio do teste de push-out. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Após sete dias, os condutos foram desobstruídos e aleatoriamente divididos em 4 grupos (n=10), de acordo com as brocas do sistema de pinos de fibra WhitePost DC (FGM) usadas: (G1) broca #2; (G2) broca #3; (G3) broca #4; (G4) broca #2. O preparo foi realizado a uma profundidade de 10 mm. A cimentação foi realizada com o cimento resinoso autoadesivo RelyX U100 (3M ESPE), e apenas nos grupos G1, G2 e G3 uma pequena quantidade de Rodamina B em pó foi usada como corante no cimento. Após uma semana, cada raiz foi seccionada em máquina de corte, obtendo-se 6 fatias de 1 0,1 mm de espessura. Antes do ensaio de push-out, imagens digitais foram obtidas, por meio de um estereomicroscópio, de ambas as faces de cada fatia, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram obtidas para determinação do modo de falha. Para determinar a espessura de cimento, foi desenvolvida uma rotina (macro) no software KS 400. Os dados foram estatisticamente analisados com análise de variância (ANOVA) 2 fatores (influência do diâmetro da broca e influência dos terços) e Kruskal-Wallis (influência da espessura do filme de cimento). Comparações múltiplas foram realizadas com o teste Duncan. Todos os testes foram aplicados com &#945;=0,05. Houve diferenças significantes entre os grupos em relação ao diâmetro da broca (p<0,0001), sendo G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). O terço do conduto exerceu influência significativa sobre a resistência adesiva (p<0,0001), sendo os maiores valores obtidos no terço apical. As espessuras do filme de cimento foram estatisticamente diferentes nos grupos. Os maiores valores de espessura de cimento foram obtidos no G3 (248,78 &#956;m), seguido de G2 (185,91 &#956;m) e G1 (110,16 &#956;m), sendo o último estatisticamente semelhante ao G4 (119,99 &#956;m). Os resultados de G1(10,04 5,13 MPa) e G4 (8,89 + 5,18 MPa) foram estatisticamente semelhantes, indicando que a presença da Rodamina B não influencia significativamente na resistência de união. O tipo de falha predominante no G1 foi mista, no G2, adesiva entre pino e cimento, e no G3 e G4, adesiva entre cimento e dentina. O diâmetro da broca influenciou significativamente nos resultados de resistência de união ao teste de push-out. O ligeiro aumento na espessura do filme de cimento promoveu um aumento nos valores de resistência, quando comparado com filmes de cimento muito finos ou muito espessos. / The present study has the purpose of evaluating the influence of the cement film thickness on the bond strength of glass fiber posts in different portions of the root canal (cervical, medium, and apical), cemented with self-adhesive resin cement, with and without the addition of Rhodamine B, by means of the push-out test. Forty roots were included in epoxy resin, underwent endodontic treatment, and were filled with gutta-percha and endodontic cement without eugenol. After seven days, the canals were de-obstructed and randomly divided into four groups (n=10), according to the WhitePost DC (FGM) fiber glass post systems burs: (G1) bur #2; (G2) bur # 3; (G3) bur #4; (G4) bur #2. The preparation was made at a 10 mm depth. The posts were cemented with RelyX U100 (3M ESPE) self-adhesive resin cement, and only in groups G1, G2, and G3 a small amount of powdered Rhodamine B was used as a stain in the cement. After one week, each root was sliced in a cutting machine, resulting in six slices 1 0,1 mm thick. Before the push-out test, a stereomicroscope was used to obtain digital images of both sides of each slice, in order to determine the radius of the posts, as well as the thickness of the cement film. After the mechanical test, new images were obtained, to determine the failure mode. In order to determine the cement thickness, a macro routine was developed in the software KS 400. The data were analyzed statistically through two-way ANOVA (influence of the bur diameter and influence of the thirds), and Kruskal-Wallis (influence of the cement film thickness). Duncan test was used for multiple comparisons. All tests were run with &#945;=0,05. There were significant differences between the groups regarding the bur diameter (p<0,0001), with G2 (14,62 5,15 MPa) > G1 (10,04 5,13 MPa) > G3 (7,68 6,14 MPa). The canal portion had significant influence on the bond strength, and the highest values were obtained at the apical third (p = 0,0001). The cement film thicknesses were statistically different in all groups. The highest cement thickness values were obtained in G3 (248,78 &#956;m), followed by G2 (185,91 &#956;m), and G1 (110,16 &#956;m), the latter being statistically similar to G4 (119,99 &#956;m). G1 (10,04 5,13 MPa) and G4 (8,89 + 5,18 MPa) showed statistically similar results, which indicates that the presence of Rhodamine B did not significantly influence the bond strength. The predominant type of failure for G1 was mixed, for G2 was adhesion between post and cement, and for G3 and G4 was adhesion between cement and dentin. The bur diameter significantly influenced the results for shear bond strength for the push-out test, as well as the cement film thickness. The slight increase in the cement thickness allowed an increase in the values of shear bond strength in comparison with very thin or very thick cement films.
40

Análise do MTA e do Ca(OH)2 no interior dos tecidos após o processo de reabsorção radicular externa em reimplante dentário tardio

Marão, Heloisa Fonseca [UNESP] 25 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-25Bitstream added on 2014-06-13T19:30:05Z : No. of bitstreams: 1 marao_hf_me_araca.pdf: 3083195 bytes, checksum: 286d537c00737b1b6f019da2785d2ccc (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A clínica tem mostrado que a maioria dos reimplantes dentários é tardia e nessa condição há necrose das células do ligamento periodontal e as reabsorções patológicas podem se instalar e levar à perda do dente. O objetivo do trabalho foi avaliar o MTA e o Ca(OH)2, no interior dos tecidos, após a reabsorção radicular externa em reimplante tardio de dente de rato. Foram utilizados 20 ratos (Rattus norvegicus albinus) machos que tiveram o incisivo direito extraído e mantido em meio seco por 60 minutos. Em seguida, a papila dentária, o órgão do esmalte, a polpa dentária e o ligamento periodontal foram removidos. Os dentes foram imersos em solução de fluoreto de sódio fosfato acidulado a 2% pH 5,5, por 10 minutos. Em seguida os canais foram secos e divididos em 2 grupos: Grupo I - canais radiculares foram preenchidos com pasta de Ca(OH)2 e soro fisiológico e Grupo II - com MTA. Os alvéolos foram irrigados com soro fisiológico e os dentes reimplantados. Após 80 dias foi possível observar extensas áreas de reabsorção por substituição e algumas inflamatória nos dois grupos experimentais. Houve uma reação inflamatória mais intensa em contato com o Ca(OH)2 quando comparado ao MTA. No fundo do alvéolo houve maior neoformação óssea no grupo do MTA, porém não houve diferença estatisticamente significante entre os grupos. È possível concluir que o MTA pode ser uma opção clínica viável para a obturação de dentes tardiamente reimplantados sujeitos à reabsorção radicular externa devido a sua biocompatibilidade com os tecidos / Clinical practice has shown that most of reimplanted teeth are late, this condition produce necrosis of periodontal ligament cells and the pathological resorption may occur and produce dental loss. The aim of this study was to assess the biological behavior of MTA and Ca(OH)2, within the tissues after external root resorption in delayed late reimplanted rat teeth. Twenty male rats (Rattus norvegicus albinus) were used. The upper right incisor was extracted and was kept in a dry environment for 60 minutes. Then, the dental papilla, the enamel organ, the dental pulp and the periodontal ligament were removed. The teeth were immersed in 2% acidulous sodium fluoride solution pH 5.5 for 10 minutes. After that, the canals were dried and divided into 2 groups: Group I - the canals were filled with Ca(OH)2 and saline and Group II - with MTA. Sockets were irrigated with saline solution and the teeth were reimplanted. After 80 days was possible to observe large areas of replacement resorption and some inflammatory root in both groups There was more intense inflammatory reaction in contact with Ca(OH)2 when compared to MTA. At the bottom of the alveolar socket, bone neoformation was greater in the group of MTA, but there was no statistically significant difference between the groups. It’s possible to conclude that MTA may be a viable clinical option for filling of late dental reimplanted subject to external root resorption due to its biocompatibility with the tissues

Page generated in 0.0963 seconds