• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
781

Efekt školy chůze na protéze na stabilitu a parametry chůze pacientů se stehenní amputací / The effect of gait training with a prosthesis on stability and parameters in patients with thigh amputation

Tučková, Tereza January 2008 (has links)
Diploma thesis "Effect of gait school with prosthesis on stability and walking parameters of patients after transfemoral amputation deals with problems of patients after transfemoral amputation due to vascular etiology. It mentions elementary knowledge of rehabilitation after amputation of lower extremity. Furthermore, there are described main complications that amputation brings into the patient ́s life: pain associated with amputation, skin complications and psychological hardships. Emphasis is laid on gait and gait practice for patients with amputation. I further deal with deviations commonly observed on gait of these patients and with factors influencing the gait, including the influence of particular parts of the prosthesis on patients ́ gait. The practical part is dedicated to comparison of two different approaches to gait practice. The effect of these approaches is evaluated on the basis of results of two groups of patients. The results were gathered by examination on force plate, measurement of gait velocity, examination of gait cadence and evaluation of patients ́s gait videos. Furthermore, I use functional tests: LCI - 5, ABIS - R, ABC scale and PEQ. All of these examinations were performed at the beginning and in the end of patients ́ stay at the Clinic of rehabilitation in Hradec Králové. The...
782

Análise por elementos finitos de próteses tipo protocolo com diferentes materiais de infraestrutura e instaladas em rebordo reabsorvido / Finite element analysis of implant-supported prostheses with different infrastructure materials and installed in reabsorbed ridge

Zaparolli, Danilo 08 February 2018 (has links)
Com o avanço da estética e da qualidade de vida, novos materiais estão sendo utilizados para substituir partes metálicas de próteses, e mais pacientes com rebordos atrofiados desejam uma reabilitação oral fixa. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas mandibulares em função da variação do material utilizado nas barras e da largura do rebordo ósseo, através de análise por elementos finitos. Dois hemiarcos mandibulares (normal e reabsorvido) foram modelados em software de computador. Dois implantes cone-morse foram inseridos em cada mandíbula, sendo reabilitados com prótese do tipo protocolo. Três materiais diferentes de barra foram utilizados: cobalto-cromo, titânio e resina reforçada por fibras de vidro. Cada prótese recebeu 500N de força oblíqua distribuída entre molar (200N) e pré-molares (150N cada). A função espelho do software de análise foi utilizada para transformar cada hemiarco em arcada total. Foram analisadas as tensões máximas e mínimas principais no osso cortical e trabecular, e a tensão equivalente Von mises na infraestrutura e componentes da prótese. A variação dos materiais de infraestrutura provocou alteração na magnitude das tensões, mas não de forma significativa e nem alterando a forma de distribuição das tensões. Já a quantidade remanescente de rebordo ósseo alterou de forma significativa tanto a magnitude quanto a distribuição das tensões máximas e mínimas principais: no implante anterior localizadas somente no pescoço do implante para a mandíbula normal e no pescoço e espiras do implante para a mandíbula reabsorvida; no implante posterior houve apenas diferença significante de intensidade das tensões, não de localização. A tensão equivalente Von mises se concentrou no micro-unit em todas as situações, sendo mais alterada pela diferença de rebordo do que de material de infraestrutura. Pode-se concluir que tanto a variação da condição do rebordo ósseo remanescente como a variação do a variação do material de infraestrutura da prótese provocaram alterações na intensidade e distribuição das tensões, sendo que a primeira provocou alterações mais significativas do que a segunda / With the advancement of aesthetics and quality of life, new materials are being used to replace metallic parts of prostheses, and more patients with atrophied ridges want a fixed oral rehabilitation. The aim of this study was to compare the stress generated by mandibular implant - supported prostheses in function of the variation of the material used in the bars and the width of the bone ridge, through finite element analysis. Two mandibular hemi arcs (normal and reabsorbed) were modeled in computer software. Two cone-morse implants were inserted into each mandible, being rehabilitated with a implant-supported prostheses. Three different bar materials were used: cobalt-chromium, titanium and fiberglass reinforced resin. Each prosthesis received 500N of oblique load distributed between molar (200N) e and premolars (150N each).. The mirror function of the analysis software was used to transform each hemi arch into total arch. We analyzed the maximum and minimum principal tensions in the cortical and trabecular bone, and the equivalent stress Von mises in the infrastructure and components of the prosthesis. The variation of the materials of infrastructure caused a change in the stress magnitude, but not in a significant way nor changing the form of stress distribution. On the other hand, the remaining amount of bone ridge significantly altered both the magnitude and the distribution of the maximum and minimum principal stresses: in the anterior implant located only in the neck of the implant for the normal mandible and in the neck and spines of the implant for the reabsorbed mandible; in the posterior implant there was only a significant difference in the intensity of the stresses, not in the location. The equivalent stress Von mises was concentrated in the micro-unit in all situations, being more affected by the ridge difference than of infrastructural material. It can be concluded that both the variation of the condition of the remaining bone ridge or the variation of the variation of the infrastructure material of the prosthesis caused changes in the intensity and distribution of the stresses, being so that the first caused more significant alterations than the second
783

Desenvolvimento de dois modelos de mini-implantes e componentes protéticos: correlação da macroestrutura e propriedades mecânicas / Development of two models of mini-implants and prosthetic components: macrostructure correlation and mechanical properties

Valente, Mariana Lima da Costa 19 January 2018 (has links)
O edentulismo acomete grande parcela da população mundial, especialmente os idosos, gerando perda da função mastigatória, desordens nutricionais, estética desfavorável e redução da qualidade de vida. Como alternativa a esses problemas, as overdentures implanto retidas tem representado uma modalidade de tratamento eficiente para reabilitação da mandíbula. Assim, o presente estudo teve por objetivo desenvolver e avaliar a efetividade de dois modelos de mini-implantes dentários e um componente protético, cápsula de retenção para overdentures mini-implante retidas. Para tal, um total de 30 mini-implantes (n=10) foram utilizados: modelo comercial Intra-Lock® System, experimental rosqueado e experimental helicoidal. Ambos os mini-implantes desenvolvidos no estudo foram confeccionados em titânio Grau IV, nas dimensões de Ø 2,0 mm x 10 mm de comprimento e submetidos a tratamento de superfície nanométrico. O desempenho dos mesmos foi comparado ao modelo comercial selecionado quanto à estabilidade primária, por meio de torque de inserção e ensaio de arrancamento e à distribuição de tensões, através dos métodos fotoelástico e de correlação de imagens digitais (CID). Foram realizados carregamentos puntiformes axiais e oblíquos (inclinação de 30º do modelo), com cargas de 100 N para a fotoelasticidade e de 250 N axial e 100 N oblíquo para a CID. Para análise do componente protético foi utilizado o teste de resistência à fadiga. 60 cápsulas (n=20): Poliacetal, Politetrafluoretileno (PTFE) e o-ring convencional (Intra-Lock®) foram capturadas aos pares, com resina acrílica e submetidas a 3625 ciclos de inserção/remoção, simulando 30 meses de uso da overdenture. A deformação interna e externa dos componentes foi avaliada por meio de Estereomicroscópio Óptico. Os dados obtidos foram submetidos a ANOVA e teste de Tukey (&alpha;=0,05). O torque de inserção (TI) e ensaio de arrancamento apresentaram significância estatística para todos os modelos (p<0,05), sendo o TI maior para o mini-implante rosqueado e a força máxima de arrancamento para o modelo Intra-Lock®. Quanto à análise de tensões por meio da fotoelasticidade verificou-se de maneira geral, maiores tensões no terço médio e apical dos mini-implantes. O mesmo padrão foi observado para a CID, porém, neste caso, com tensões significativamente maiores (p<0,05) para os mini-implantes rosqueados na condição de carregamento axial, para o oblíquo não foram encontradas diferenças significativas (p>0,05). Quanto à análise dos componentes protéticos, a cápsula de poliacetal apresentou a maior retenção (p<0,05), seguida do o-ring e PTFE. Menor deformação foi observada para o o-ring (p<0,05) e maior deformação interna (p<0,05), após a realização da fadiga, para o poliacetal. O mini-implante rosqueado apresentou de modo geral estabilidade primária e distribuição de tensões comparável ao modelo comercial avaliado. O componente protético de poliacetal demonstrou superioridade em relação ao o-ring da Intra-Lock® quanto à força de retenção e apesar da maior deformação interna sofrida, sugere-se sua substituição após no mínimo 30 meses de uso da overdenture / Edentulism affects a large part of the world population, especially the elderly, generating loss of masticatory function, nutritional disorders, unfavorable esthetics and reduction of quality of life. As an alternative to these problems, overdentures implant retained have represented an efficient treatment modality for mandibular rehabilitation. Thus, the present study aimed to develop and evaluate the effectiveness of two models of dental mini-implants and a prosthetic component, retention caps for overdentures mini-implant retained. To do this, a total of 30 mini-implants (n=10) were used: Intra-Lock® System commercial model, experimental threaded and experimental helical. Both mini-implants developed in the study were made in Titanium Grade IV, in the dimensions of Ø 2.0 mm x 10 mm in length and submitted to a nanometric surface treatment. Their performance were compared to the commercial model selected for primary stability by means of insertion torque and pullout test and stress distribution using photoelastic and digital image correlation (DIC) methods. Axial and oblique punctiform loads (30º inclination of the model) were performed, with loads of 100 N for photoelasticity and 250 N axial and 100 N oblique for DIC. For the analysis of the prosthetic component, the fatigue strength test was used. 60 capsules (n=20): Polyacetal, Polytetrafluoroethylene (PTFE) and conventional O-ring (Intra-Lock®) were captured in pairs with acrylic resin and subjected to 3625 insertion/removal cycles, simulating 30 months of overdenture use. The internal and external deformation of the components was evaluated using an Optical Stereomicroscope. Data were submitted to ANOVA and Tukey\'s test (&alpha;=0.05). The insertion torque (IT) and pullout test were statistically significant for all models (p<0.05), with IT being highest for the threaded mini-implant and maximum pulling force for the Intra-Lock® model. As for stress analysis by photoelasticity, it was generally observed that there were higher tensions in the middle and apical third of the mini-implants. The same pattern was observed for the DIC, but in this case, with significantly higher stresses (p<0.05) for the mini-implants threaded in the axial loading condition, no significant differences were found for the oblique (p>0.05). As for the analysis of prosthetic components, the polyacetal caps presented the highest retention (p<0.05), followed by o-ring and PTFE. Lower deformation was observed for o-ring (p<0.05) and greater internal deformation (p<0.05), after fatigue, for polyacetal. The threaded mini-implant generally showed primary stability and strain distribution comparable to the commercial model evaluated. The polyacetal prosthetic component showed superiority over the Intra-Lock® o-ring for the retention force and despite the greater internal deformation suffered, it is suggested to replace it after at least 30 months of overdenture use
784

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Pita, Murillo Sucena 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
785

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Lima, Vicente José Muratore de 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
786

Avaliação da adaptação marginal e interna de coroas de dissilicato de lítio confeccionadas pelo sistema CAD/CAM após escaneamento direto e indireto / Evaluation of the marginal and internal adaptation of lithium disilicate crowns made by the CAD / CAM system after direct and indirect scanning

Freitas, Bruna Neves de 15 December 2017 (has links)
O objetivo desse estudo foi avaliar a adaptação interna e marginal de coroas de dissilicato de lítio obtida por duas técnicas disponíveis pelo sistema CAD/CAM, o escaneamento direto e indireto. As análises foram realizadas por meio do microtomógrafo computadorizado (&microCT), microscópio confocal a laser (CL) e técnica da replica (TR), em dois momentos: antes e após a cristalização do material. O dente 14 de manequim foi preparado e duplicado em silicone, obtendo 20 réplicas em resina de poliuretano. Para a formação do Grupo 1 (IND/n=08), o manequim foi moldado com moldeira de estoque e silicone de adição com técnica de moldagem simultânea e modelagem com gesso pedra tipo III e IV, totalizando oito modelos em gesso. Os modelos foram escaneados com escâner indireto. Foram fresadas oito coroas de dissilicato de lítio. Para formação do Grupo 2 (DIR/n=08), o manequim foi escaneado com escâner direto. Oito imagens foram obtidas e enviadas ao laboratório pelo programa do sistema. Da mesma forma, foram fresadas oito coroas de dissilicato de lítio. As leituras da adaptação marginal das coroas foram realizadas com as mesmas adaptadas sobre a respectiva réplica em poliuretano, no &microCT, CL, e TR. As leituras da adaptação interna foram realizadas no &microCT e TR. As análises foram realizadas antes e após a cristalização das coroas. Os dados que apresentaram distribuição normal foram analisados por ANOVA dois fatores e os dados que não apresentaram distribuição normal foram analisados por teste U de Mann-Whitey para comparação entre os Grupos e pelo teste de Wilcoxon para comparação antes e após a cristalização. Em relação à adaptação axial, foi verificada diferença significante apenas para os Tempos (p=0,017), com menores valores após a cristalização. Para a adaptação interna não foi observada diferença entre os Grupos (p>0,05) ou Tempos estudados (p>0,05). Para a adaptação marginal vertical houve diferença para o Grupo IND, com maiores valores após a cristalização independente da metodologia de análise (&microCT - p=0,001; confocal - p=0,038). Já a medida marginal horizontal apresentou resultados divergentes de acordo com a metodologia utilizada. No &microCT, IND foi maior que DIR (p=0,003) e antes maior que após a cristalização (p<0,001). No confocal, IND menor que DIR após a cristalização (p=0,05), e para DIR, antes menor que após a cristalização (p=0,005). No volume total e volume marginal do espaço para cimentação houve diferença significante apenas para o DIR, com maiores valores após a cristalização (volume total - p=0,025; volume marginal - p=0,002). Pelos resultados obtidos pode-se concluir que há contração do material após a cristalização, resultando em maior desadaptação comprovado pelo aumento do volume total do espaço de cimentação em consequência da dificuldade de assentamento da coroa de dissilicato de lítio. / The objective of this study was to evaluate the internal and marginal adaptation of lithium desilicated crowns obtained by two alternative techniques to the CAD / CAM system, direct and indirect scanning. The analyzes were carried out by computerized microtomograph, laser confocal microscope and replica technique, in two moments: before and after the crystallization of the material. The manikin tooth 14 was prepared for total crown. Then it was duplicated, in silicone, and there were obtained 16 replicas in polyurethane resin. Two groups were formed from the impression of the manikin through the direct and indirect scanning, For the Group 1 (IND/n = 08), the manikin was molded with stock tray, with addition silicone, by the simultaneous molding technique and modeling performed with gypsum stone type III and IV, totaling eight molds and plaster models. The models were sent to the laboratory for scanning on the scanner indirect. Dissilicate crowns were made of lithium milled. For the Group 2 (DIR/n = 08), the dummy was scanned by scanner directly. The eight images obtained were sent directly to the laboratory by the system program. Likewise, milled lithium dissilicate crowns were made. The marginal adaptation of the crowns was performed with the same ones on the respective polyurethane tooth, in the computerized microtomograph (&microCT), confocal laser microscope (CL) and through the replica technique (TR). Internal adaptation readings were performed using a &microCT and TR. The analyses were made before and after the crystallization of the crowns. The data showed normal distribution were analyzed by two factors ANOVA and the data did not show normal distribution were analyzed for U Mann-Whitney test for comparison among groups and by the Wilcoxon test for comparison before and after the crystallization . In relation to the axial adaptation, significant difference was verified only for Times (p = 0.017), with lower values after crystallization. For the internal adaptation was not observed difference between groups (p > 0.05) or Times studied (p > 0.05). For the vertical marginal adaptation difference to the IND group, with higher values after the crystallization analysis methodology-independent (&microCT p = 0.001;-p = 0.038 confocal). Already the measure presented divergent results horizontal marginal according to the methodology used. In &microCT, IND was greater than DIR (p = 0.003) and greater than after the crystallization (p < 0.001). In confocal IND less than DIR after the crystallization (p = 0.05), and DIR, before less than after the crystallization (p = 0.005). In total volume and marginal volume of space for cementation significant difference only to the DIR, with higher values after the crystallization (total volume - p = 0.025; marginal volume - p = 0.002). The results obtained can be concluded that there is contraction of the material after the crystallization, resulting in higher leakage evidenced by the increase of the total volume of the cementing space as a result of the settling difficulty the dissilicate Crown.
787

Eficácia da escovação associada à irrigação oral na manutenção dos tecidos peri-implantares e overdentures estudo clínico randomizado / Effectiveness of brushing associated with oral irrigation in maintenance of peri-implant tissues and overdentures randomized clinical trial

Salles, Marcela Moreira 27 January 2017 (has links)
A manutenção das próteses implantossuportadas e da saúde dos tecidos peri-implantares está diretamente relacionada ao sucesso do tratamento reabilitador. O objetivo deste trabalho foi avaliar, por meio de estudo clínico randomizado, a eficácia de um método experimental (escovação associada à irrigação oral), na manutenção dos tecidos peri-implantares e overdentures. Foram analisadas capacidade de remoção de biofilme e manutenção da saúde dos tecidos orais, ação antimicrobiana e satisfação do paciente. Foram selecionados 38 pacientes usuários de prótese total superior convencional e overdenture inferior, retida por implantes ou mini-implantes e sistema de encaixe tipo o\'ring. Os pacientes utilizaram os seguintes métodos: ES (Controle): método mecânico da escovação - escova específica para próteses totais, escova dental de cerdas macias e dentifrício e WP (Experimental): associação da escovação com a irrigação oral (Waterpik). Os pacientes foram orientados a higienizar suas próteses e tecidos peri-implantares, por meio do método da escovação, por 2 minutos, 3 vezes ao dia, sendo que no método experimental, os pacientes utilizaram a irrigação oral, uma vez ao dia, após a escovação, direcionando o jato de água à margem gengival e região dos componentes protéticos das overdentures. Todos os pacientes utilizaram os dois métodos de higiene, em uma sequência aleatória, por um período de 14 dias, com um período intercalado de 7 dias de wash out. As avaliações foram realizadas antes (baseline) e após a utilização de cada método. A capacidade de remoção de biofilme e a manutenção da saúde oral dos tecidos foram avaliadas por meio do Índice de Placa Modificado (IP), Índice Gengival (IG), Profundidade de Sondagem (PS) e Índice de Sangramento à Sondagem (SS). Para a análise da ação antimicrobiana, o biofilme subgengival foi coletado por meio de cones de papel e biofilme presente nos componentes das overdentures por meio de microbrush, e as amostras coletadas foram processadas pela técnica de hibridização DNA Checkerboard (39 espécies microbianas avaliadas). Os pacientes responderam a um questionário específico por meio de Escala Visual Analógica (EVA) de 100,0 mm, após o uso de cada método. Os dados relacionados aos parâmetros clínicos e à ação antimicrobiana foram analisados por meio do teste de Friedman (&alpha;=0,05), seguido de comparações realizadas por meio do teste de Wilcoxon; as comparações entre implantes convencionais e mini-implantes foram realizadas por meio do teste de Mann-Whitney (&alpha;=0,05). A análise das respostas ao questionário de satisfação foi realizada por meio do teste de Wilcoxon (&alpha;=0,05). Os resultados mostraram que, quanto aos parâmetros clínicos, houve diferença estatisticamente significante entre os valores obtidos no baseline e os valores após os métodos avaliados (p<0,001); entre os métodos ES e WP, não houve diferença significante (IP, IG e PS: p=1,000; SS: p=0,828); houve diferença estatisticamente significante entre os diferentes tipos de implantes apenas do IP após ES (p<0,05). Houve diferença estatisticamente significante entre os métodos (p<0,05), quando comparados os valores da quantidade total de células microbianas presentes no biofilme subgengival, sendo WP mais efetivo que ES (p<0,05), porém não houve diferença entre baseline e WP (p>0,05); considerando os micro-organismos avaliados, WP promoveu redução mais efetiva que ES apenas da espécie C. rectus (p=0,001). A quantidade total de células microbianas presentes nos componentes das overdentures nas avaliações foi semelhante (p=0,607) e a microbiota identificada apresentou-se qualitativamente semelhante após cada um dos métodos. Não houve diferença estatisticamente significante entre os diferentes tipos de implantes quanto ao total de células microbianas presentes no sulco peri-implantar e nos componentes das overdentures, identificadas em cada uma das avaliações (p>0,05). As médias das respostas ao questionário de satisfação após ambos os métodos foram altas (acima de 80,0 mm) para todas as questões, porém não houve diferença estatisticamente significante entre as respostas dadas após o uso de ES e WP (p>0,05). Concluiu-se que o método experimental foi eficaz na redução dos parâmetros clínicos avaliados; apresentou ação antimicrobiana mais efetiva na redução da quantidade total de micro-organismos presentes no biofilme subgengival; porém, não apresentou ação antimicrobiana frente aos micro-organismos presentes nos componentes protéticos das overdentures; e proporcionou alto nível de satisfação do paciente. / The maintenance of implant-supported prostheses and peri-implant health is directly related to the success of rehabilitation treatment. The aim of this study was to evaluate, through randomized clinical trial, the efficacy of an experimental method (brushing associated with oral irrigation) in the maintenance of the peri-implant tissues and overdentures. Biofilm removal capacity and oral tissues health maintenance, antimicrobial action and patient satisfaction were analyzed. Thirty-eight patients, users of conventional maxillary complete denture and mandibular overdenture retained by implants or mini-implants and o\'ring-retained system, were selected. The patients utilized the following methods: MB (Control): mechanical brushing method specific brush for dentures, soft bristle toothbrush and dentifrice, and WP (Experimental): association of mechanical brushing with oral irrigation (Waterpik). Patients were instructed to clean their dentures and peri-implant tissues, by means of brushing method for 2 minutes, 3 times a day, and in the experimental group, patients used the oral irrigation, once a day, after brushing, directing the water jet to the gingival margin and the region of the prosthetic components of the overdentures. All patients used both hygiene methods in a random sequence for a period of 14 days, with a 7-day wash-out interposed period. The evaluations were performed before (baseline) and after using each method. Biofilm removal capacity and oral tissues health maintenance were evaluated through Modified Plaque Index (PI), Gingival Index (GI), Probing Depth (PD), and Bleeding on Probing Index (BP). For the antimicrobial action analysis, the subgingival biofilm was collected by means of sterile paper cones and the biofilm present on the overdentures components by microbrush, and the collected samples were processed by the Checkerboard DNA hybridization technique (39 microbial species evaluated). Patients answered to a specific questionnaire using the Visual Analogue Scale (VAS) of 100.0 mm, after application of each method. The data related to clinical parameters and antimicrobial activity were analyzed using the Friedman test (&alpha;=0.05), followed by comparisons using the Wilcoxon test; comparisons between conventional implants and mini-implants were performed using the Mann-Whitney test (&alpha;=0.05). The analysis of the satisfaction questionnaire responses was performed using the Wilcoxon test (&alpha;=0.05). The results showed that, regarding clinical parameters, there was a statistically significant difference between the values obtained at baseline and the values after the evaluated methods (p<0.001); between the MB and WP methods there was no significant difference (PI, GI and PD: p=1.000; BP: p=0.828); there was a statistically significant difference between the different types of implants only of PI after MB (p<0.05). There was a statistically significant difference between the methods (p<0.05) when comparing the values of the total amount of microbial cells in the subgingival biofilm, WP being more effective than MB (p<0.05), but there was no difference between baseline and WP (p>0.05); considering the evaluated microorganisms, WP promoted a more effective reduction than MB only of the C. rectus species (p=0.001). The total amount of microbial cells present in the components of overdentures in the evaluations was similar (p=0.607) and the identified microbiota appeared qualitatively similar after each method. There was no statistically significant difference between the different types of implants for the total microbial cells in the peri-implant sulcus and in the overdentures components identified in each of the evaluations (p>0.05). The means of the satisfaction questionnaire responses after both methods were high (above 80.0 mm) for all the questions, but there was no statistically significant difference between the answers given after the use of ES and WP (p>0.05). It was concluded that the experimental method was effective in reducing the clinical parameters evaluated; presented more effective antimicrobial action in reducing the total amount of microorganisms present in the subgingival biofilm; however, showed no antimicrobial action against microorganisms present in the prosthetic components of the overdentures; and provided high level of patient satisfaction.
788

Custo direto do implante por cateter de bioprótese valvar aórtica nas diferentes vias de acesso / Direct cost of transcatheter aortic valve implantation in the different access routes

Bittar, Eliana 31 March 2017 (has links)
Introdução: Uma nova alternativa de tratamento foi desenvolvida, o Implante por Cateter de Bioprótese Valvar Aórtica (TAVI, em inglês, Transcatheter Aortic Valve Implantation), indicado para os pacientes portadores de estenose aórtica grave com várias comorbidades, considerados inoperáveis pelo tratamento cirúrgico convencional. O TAVI ainda não foi incorporado ao rol de políticas de saúde do Brasil pelo Sistema Único de Saúde (SUS), tampouco pela Agência Nacional de Saúde Suplementar (ANS), pois há escassez de evidências científicas fundamentadas em análise econômica do procedimento que relatem os resultados e o custo a longo prazo em comparação à cirurgia convencional. Objetivo: Identificar o custo direto médio do implante por cateter de bioprótese valvar aórtica, verificar se há alteração significativa de custo nas diferentes vias de acesso utilizadas e identificar os fatores preditores que possam elevar o custo do procedimento. Método: Trata-se de uma pesquisa com abordagens quantitativa, exploratória, descritiva, transversal, retrospectiva e documental, realizada em um hospital da Secretaria de Estado de Saúde de São Paulo (SES-SP), da Administração Direta, especializado no tratamento de doenças cardiovasculares de alta complexidade. A população do estudo correspondeu aos procedimentos eletivos do TAVI, desde a inauguração da sala híbrida, em março de 2012, até agosto de 2015, totalizando 108 procedimentos, sendo 92 por via transfemoral, 8 por via transapical e 8 por via transaórtica. Resultados: O custo direto médio dos procedimentos TAVI nas três vias totalizou R$ 82.230,94. Por via transfemoral, esse custo médio foi de R$ 82.826,38; por via transaórtica, R$ 79.440,91; e por via transapical, R$ 78.173,41. O total de material e medicamento/solução representou, por via transfemoral, 91,89% do total do custo direto médio do procedimento TAVI; por via transapical, 91,81%; e por via transaórtica, 90,69%, e o custo fixo com a válvula transcateter, no valor de R$ 65 mil, representou 78,47% sobre o custo total do procedimento TAVI, por via transfemoral; 83,14%, por via transapical; e 81,82%, por via transaórtica. O Teste Kruskal-Wallis Teste das Variáveis Contínuas apresentou diferença estatisticamente significativa entre as vias de acesso. No custo total do procedimento TAVI, o Teste de Bonferroni mostrou diferença na associação entre as vias transfemoral e transapical. No entanto, na associação com a via transaórtica, não apresentou diferença estatisticamente significativa. Os fatores preditores que elevaram o custo do procedimento TAVI foram: vias de acesso, duração do procedimento, material de hemodinâmica, medicamento/solução, material de consumo, material de perfusão, total de material e medicamento/solução, recursos humanos, gases medicinais, depreciação e energia. A segunda válvula foi a única variável referente às intercorrências no Centro Cirúrgico que elevou o custo do procedimento. A média de idade dos pacientes com indicação ao TAVI foi de 81,50 ±6,96 anos. Conclusão: O TAVI é um avanço a ser discutido e acompanhado, havendo a necessidade de reforçar novas pesquisas que avaliem os benefícios do tratamento com base nos resultados e custos, a fim de auxiliar na tomada de decisão para incorporação desse tratamento para o público-alvo, melhorando a qualidade de vida dos pacientes e proporcionando a integração destes novamente às atividades diárias. / Introduction: A new treatment alternative has been developed, the Transcatheter Aortic Valve Implantation (TAVI), indicated for patients with severe aortic stenosis with various comorbidities deemed inoperable by conventional surgical treatment. TAVI has not yet been incorporated into the Brazilian health policies by the Public Health System (SUS), or by the National Supplementary Health Agency (ANS), because there is a shortage of scientific evidence based on an economic analysis of the procedure that reports the results and the long-term costs compared to conventional surgery. Objective: To identify the average direct cost of the transcatheter aortic valve implantation, to verify if there is significant change of cost in the different access routes used, and to identify predictive factors that could increase the cost of the procedure. Method: This is a study with quantitative, exploratory, descriptive, transversal, retrospective, and documentary approaches, carried out in a hospital of the State Department of Health of São Paulo (SES-SP), of the Direct Administration, specialized in the treatment of high-complexity cardiovascular diseases. The study population corresponded to TAVI elective procedures, from the inauguration of the hybrid room, in March 2012, up to August 2015, totaling 108 procedures, of which 92 were transfemoral, 8 were transapical, and 8 were transaortic. Results: The average direct cost of the TAVI procedures in the three routes totaled R$ 82,230.94. Transfemorally, this average cost was R$ 82,826.38; through the transaortic route, R$ 79,440.91; and through the transapical route, R$ 78,173.41. The total material and medication / solution represented 91.89% of the total average direct cost of the TAVI procedure through the transfemoral route; 91.81% through the transapical route; and 90.69% through the transaortic route, and the fixed cost with the transcatheter valve, in the amount of R$ 65,000.00, represented 78.47% of the total cost of the TAVI procedure through the transfemoral route; 83.14%, through the transapical route; and 81.82% through the transaortic route. The Kruskal-Wallis Test Continuous Variables Test showed a statistically significant difference among the access routes. In the total cost of the TAVI procedure, the Bonferroni Test showed a difference in the association between the transfemoral and transapical routes. However, in the association with the transaortic route, there was no statistically significant difference. Predictive factors that increased the cost of the TAVI procedure were: access routes, length of procedure, hemodynamic material, drug / solution, consumption material, infusion material, total material and medicine/solution, human resources, medical gas, depreciation and energy. The second valve was the only variable related to the complications in the or that increased the cost of the procedure. The mean age of patients with TAVI was 81.50 ± 6.96 years. Conclusion: TAVI is an advance to be discussed and monitored, and there is a need to encourage new studies that evaluate the benefits of treatment based on the results and costs, in order to assist in the decision making for the incorporation of this treatment into its population, improving the quality of life of patients and providing once again their integration into daily activities.
789

Avaliação de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias / Evaluation of experimental titanium alloys for prosthodontic frameworks

Queiroz, Adriana Cláudia Lapria Faria 29 May 2009 (has links)
A utilização do titânio em odontologia tem aumentado devido suas propriedades mecânicas, biocompatibilidade, resistência à corrosão e baixo peso específico. Entretanto, o uso do titânio em próteses ainda não é rotineiro em virtude de dificuldades no processo de fundição. Uma das maneiras de superar estas dificuldades seria através do desenvolvimento de novas ligas cujo ponto de fusão fosse inferior ao do Ti cp. O objetivo deste estudo foi avaliar as propriedades mecânicas, biológicas e microestrutura de ligas experimentais de titânio para utilização em estruturas metálicas de próteses dentárias, após fundição odontológica, comparando-as ao Ti cp. As ligas experimentais avaliadas foram Ti-5Zr(%p), Ti-5Ta(%p) e Ti-5Ta-5Zr(%p). Os corpos-de-prova foram fundidos por arco voltaico em atmosfera de argônio e injeção por vácuo-pressão. Para avaliação das propriedades mecânicas, corpos-deprova em forma de halteres foram submetidos a ensaios de tração, barras foram submetidas a ensaios de flexão para avaliação do módulo de elasticidade, e hemi-esferas e discos foram submetidos ao teste de desgaste de dois corpos, sendo o perfil das amostras avaliado antes e após o teste para cálculo da perda de altura vertical. Discos foram utilizados para avaliação da microdureza e para caracterização microestrutural. Para avaliação das propriedades biológicas, células SCC9 foram cultivadas em meio de cultura D-MEM/HF12 suplementado sobre discos e poços sem discos foram usados como controle. Após períodos de 1, 4, 7, 10 e 14 dias, foi avaliada a proliferação celular pelo método histoquímico MTT. Aos 7 dias foi avaliada a viabilidade celular após marcação com azul de Trypan e contagem em hemocitômetro. A morfologia celular foi avaliada às 2, 12 e 24 horas através da visualização, em microscópio de fluorescência por epiluminação, do citoesqueleto de actina e dos núcleos, usando, respectivamente, faloidina e DAPI. Os resultados foram submetidos a testes estatísticos e a liga Ti-5Ta apresentou resistência à tração menor que as demais e módulo de elasticidade significativamente menor do que o Ti cp, embora não diferente das demais ligas experimentais. Com relação à resistência à abrasão, as ligas experimentais apresentaram desgaste significativamente menor do que o Ti cp e a liga Ti-5Zr apresentou microdureza significativamente maior do que os demais materiais. Não houve diferença na proliferação e na viabilidade celular entre os materiais. A avaliação da morfologia celular mostrou diferença na proporção de células nos diferentes estágios de desenvolvimento nos períodos de 2 e 12 horas, mas não em 24 horas. O Ti cp apresentou microestrutura do tipo feather-like com fase &alpha;, enquanto Ti-5Zr apresentou estrutura do tipo Widmanstätten com fase &alpha; e &alpha;´. As ligas Ti- 5Ta e Ti-5Ta-5Zr apresentaram as fases &alpha;, &alpha;´, &alpha;´´ e &beta;, com arranjos lamelar e acicular, respectivamente. Os resultados deste estudo sugerem que as ligas estudadas apresentam potencial para aplicação em próteses dentárias, uma vez que suas propriedades biológicas foram semelhantes às do Ti cp, comprovado por proliferação, viabilidade e morfologia celular; e suas propriedades mecânicas, como resistência à abrasão, microdureza e resistência à tração foram satisfatórias, ainda que o módulo de elasticidade possa e deva ser melhorado. / The use of titanium in dentistry have increased due to its mechanical properties, biocompatibility, corrosion resistance and density. However, titanium has not been routinely used because of the difficulties related to casting technique. One of the options to solve these difficulties would be to develop new titanium alloys whose melting point was lower than cp Ti. So, the aim of this study was to evaluate the mechanical and biological properties and microstructure of experimental titanium alloys for prosthesis frameworks, after dental casting, comparing to cp Ti. The experimental alloys evaluated were Ti-5Zr(%w), Ti-5Ta(%w) and Ti-5Ta-5Zr(%w). The samples were cast by voltaic arc in argon atmosphere and vaccum/pressure injection. To evaluate the mechanical properties, dumbbell-shaped samples were submitted to tensile test, slab-shaped were submitted to flexure for modulus of elasticity evaluation, and stylus tips and disks were submitted to two-body wear test, evaluating the profile of the samples before and after the test to calculate vertical height loss. Disks were used for microhardness evaluation and microstructural observation. For the biological properties evaluation, SCC9 cells were cultured in D-MEM/HF12 supplemented on the disks and wells without disks were used as control. After 1, 4, 7, 10 and 14-day period, cell proliferation was measured by MTT method. After 7 days, cell viability was evaluated after Trypan blue marking and counting in a hemacytometer. Cell morphology was evaluated in 2, 12 and 24-hour periods examining, in fluorescence microscope under epifluorescence, actin cytoskeleton and cell nuclei, using, respectively, phalloidin and DAPI. The results were submitted to statistical analysis and Ti-5Ta alloy presented ultimate tensile strength lower than the others and modulus of elasticity statistically lower than cp Ti, but no different to the other experimental alloys. In relation to wear resistance, the experimental alloys presented wear significantly lower than cp Ti and the Ti-5Zr alloy presented microhardness greater than other materials. Cell morphology evaluation showed difference in the proportion of cells in the different stages in 2 and 12-hour periods, but not in 24. The cp Ti presented feather-like structure with &alpha; phase while Ti-5Zr presented a Widmanstätten structure with &alpha; and &alpha;´ phases. The Ti-5Ta and Ti-5Ta-5Zr alloys presented &alpha;, &alpha;´, &alpha;´´ and &beta; phases with lamellar and acicular structures, respectively. The results of this study suggest that the studied alloys could be applied in dental prosthesis, once their biological properties were similar to cp Ti in cell proliferation, viability and morphology; and their mechanical properties, like wear resistance, microhardness and ultimate tensile strength were ideal, although the modulus of elasticity can and should be improved.
790

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Teixeira, Wendel 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.

Page generated in 0.0566 seconds