• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 52
  • 24
  • 21
  • 18
  • 15
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Comparação entre implantes unitários de superfície tratada e não tratada por sub-tração radiográfica digital em protocolos de carga imediata e convencional / Comparison between single-tooth treated and non treated surface implants by digital subtraction radiography on immediate and con-ventional loading protocols

CARNEIRO, Luciano Sandoval 27 March 2009 (has links)
Made available in DSpace on 2014-07-29T15:21:59Z (GMT). No. of bitstreams: 1 Dissertacao - Luciano Sandoval Carneiro.pdf: 579690 bytes, checksum: 7c2af9622df94b48e0c190f4b97fbcff (MD5) Previous issue date: 2009-03-27 / Objectives: To compare by digital subtraction radiography (SR), matched to clinical evaluation, bone response to single-tooth treated (TS) and non-treated (NTS) surface implants on immediate (IM) and conventional (CO) loading protocols. Material and methods: 12 patients (8 underwent IM protocol and 4 underwent CO protocol) received 24 implants. Each subject received 2 implants (one with TS and the other NTS) homologously and bilaterally positioned in maxillae (lateral incisor, canine or premolar regions) or mandible (molar area). Standardized radiographies of each implant were taken on the day after implant placement (baseline image) and after 3, 6 and 12 months (follow-up images). SR was used for crestal bone loss (CBL) and peri-implant bone density (PIBD) measurements. The placement torque and resonance frequency (at 0, 6 and 12 months) were also measured for matching radiographic data. Results: T-test revealed no statistically significant difference in CBL between TS and NTS implants, while TS implants presented higher PIBD in the mid-implant region at 3-months recall (p = 0.04). For IM protocol, the Mann-Whitney test revealed higher CBL at 6-months follow-up (p = 0.03), greater PIBD at 12-months recall (p = 0.06; p = 0.07) and increasing PIBD through time. There was a positive correlation between primary stability and PIBD at 12-months recall (r = 0.58; p = 0.005). Conclusions: TS and NTS implants presented similar performances with regard to CBL and PIBD. IM and CO protocols were similarly successful. Primary stability was an important element in reaching greater PIBD after 1-year loading period / Objetivos: O objetivo desse estudo foi comparar através da subtração radiográfica digital (SRD), associada à avaliação clínica, a resposta óssea a implante unitário de superfície tratada (ST) e a implante de superfície não tratada (SNT) utilizando protocolos de carga imediata (CI) e convencional (CON). Material e métodos: 12 pacientes (8 pelo protocolo de CI e 4 pelo protocolo de CON) receberam um total de 24 implantes. Cada indivíduo recebeu dois implantes, um de ST e outro de SNT, em posições homólogas bilaterais na maxila (regiões de incisivos laterais, caninos ou pré-molares) ou na mandíbula (área de molares). Imagens radiográficas padronizadas de cada implante foram obtidas no dia seguinte após procedimento cirúrgico de instalação (imagem de referência) e em 3, 6 e 12 meses seguintes (imagens de controle). As imagens foram submetidas à SRD para avaliação da perda de crista óssea alveolar (PCO) e obtenção da densidade óssea peri-implantar (DOPI). Além das radiografias padronizadas, o torque de inserção e a freqüência de ressonância dos implantes (em 0, 6 e 12 meses) foram medidos com finalidade de correlacioná-los à avaliação radiográfica. Resultados: O teste T revelou ausência de diferença estatisticamente significativa entre implantes de ST e SNT em relação a PCO, enquanto o grupo de ST apresentou maior DOPI apenas na região de terço médio no controle de 3 meses (p = 0,04). Para o grupo submetido ao protocolo de CI, o teste de Mann-Whitney demonstrou maior PCO no controle de 6 meses (p = 0,03), maior DOPI no controle de 12 meses (p = 0,06; p = 0,07) e DOPI crescente ao longo do tempo. Houve uma correlação positiva entre a estabilidade primária e a DOPI no controle de 12 meses (r = 0,58; p = 0,005). Conclusões: Os implantes de ST e SNT apresentaram comportamentos semelhantes quanto a PCO e DOPI. O protocolo de CI exibiu sucesso comparável ao do protocolo de CON. A estabilidade primária dos implantes foi um fator importante para atingir maior DOPI após 1 ano sob a ação de carga
32

\"Estudo comparativo da cefalometria do perfil tegumentar com base na análise facial de Arnett relacionada à horizontal verdadeira com a realizada a partir do plano de Frankfurt horizontal\" / A comparative study of the cephalometric of the soft tissue profile based on Arnett´s facial analysis in relation to the true horizontal as this has been put into practice starting from the Frakfurt horizontal plane.

Sousa, Cláudia Maria Romano de 23 March 2007 (has links)
Nesta pesquisa foi comparada a diferença das medidas obtidas utilizando-se a análise cefalométrica do perfil tegumentar tendo como base a análise facial de Arnett relacionada à Horizontal Verdadeira com a análise cefalométrica do perfil tegumentar feita a partir do Plano de Frankfurt. Utilizamos 140 radiografias cefalométricas requisitadas como parte de documentação ortodôntica, obtidas de pacientes com idade variando de 06 a 49 anos, sendo 64 do sexo masculino e 76 do sexo feminino, pertencentes ao arquivo do IOM - (Instituto de Odontologia Multidisciplinar) ? RJ. As radiografias cefalométricas em norma lateral foram obtidas pelo mesmo operador, obedecendo ao protocolo adotado pelo IOM. Todos os pacientes foram orientados a assumir a Posição Natural da Cabeça, tendo como referência um espelho posicionado a frente e a Linha Vertical Verdadeira foi obtida por meio da utilização de um fio metálico unido à um prumo de chumbo, posicionado próximo à margem anterior do chassi porta-filme, de forma que apareça à frente do perfil tegumentar do paciente. A partir das medidas lineares obtidas nas Análises Cefalométricas dos Tecidos Moles, foram realizadas análises estatísticas visando dois objetivos: comparar as medidas de A à I obtidas nos traçados (um utilizando como referência uma perpendicular ao Plano Horizontal de Frankfurt e o outro à Linha Vertical Verdadeira) e analisar os resultados comparativamente. Após a análise estatística (Kolmogorov-Smirnov, para distribuição normal de dados; t-Student para amostras emparelhadas e teste não paramétrico de Wilcoxon) e a interpretação dos resultados obtidos, concluímos que houve diferenças significantes entre as formas de medidas das variáveis A, B, C, D, F, G e I, pois o valor do nível descritivo (p-valor) se apresentou abaixo de 0,05. Entretanto para as medidas E e H o valor do nível descritivo (p-valor) se apresentou maior que 0,05, demonstrando não haver diferenças significantes entre as formas dessas medidas. As correlações entre as medidas apresentadas estabelecidas pela análise facial de Arnett, de acordo com este estudo, não deverão ser utilizadas em pacientes que se submeteram à radiografias cefalométricas realizadas a partir do Plano Horizontal de Frankfurt, salvo no caso da distância interlabial, representada pela medida H, que além de não apresentar diferenças significantes neste estudo, não tem, segundo a análise de Arnett, correlação com nenhuma outra medida. / In this research a comparison was made between the differences in measurements obtained using the soft tissue profile?s cephalometric analysis based on Arnett?s facial analysis related to the true vertical with the cephalometric analysis of soft tissue profile based on the Frankfurt Plan. A total of 140 lateral cephalometric radiographs were used as part of the orthodontic documentation, taken from patients whose ages ranged from 06 to 49 years of age, of these 64 males and 76 females, being part of the files of the IOM (Instituto de Odontologia Multidisciplinar do Rio de Janeiro). The lateral cephalometric radiographs were obtained from the same operator obeying the protocols adapted by the IOM. All patients were oriented to place themselves in the Natural Head Posture using, as a reference, a mirror in front of then and the true vertical line was obtained using a metal wire and a plumb-line, placed close to the frontal chassis of the film chamber, in such a way that it appears in front of the soft tissue profile of the patient. Parting from the lineal measurements obtained from the Cephalometric Analyses of the Soft Tissues statistical analyses were made relating to two objectives: to compare the measurements from A to I obtained from the drafts/ sketches (one using as it reference a perpendicular to the Frankfurt Horizontal Plane and the other the True Vertical Line), comparatively analyse these results. After the statistical analysis (Kolgomorov Smirnov) for a normal data distribution: t-student for matched pairs and the no-parametric Wilcanox test) and the analysis of the results obtained, it was concluded that there were significant differences between the forms of the measurements of the variables A, B, C, D, F, G and I since the descriptive value (p-value) was below 0,05. The measurements for E and H, however, being over 0,05, showing than there were no significant differences between these forms of measurement. The correlation between the demonstrated measurements established by Arnett?s facial analysis, in accordance with this study, should not be used in patients who have undergone lateral cephalometric radiograph initiated on the basis of the Frankfurt Horizontal Plane except in the case of interlabial distance represented by the measurement H, which even differences in this study, does not have, according to Arnett?s studies, correlations with any other measurements.
33

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Nascimento, Marcelo Zanchetta do 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
34

Comparação do planejamento em implantodontia por radiografia panorâmica e tomografia computadorizada de feixe cônico

ANDRADE, Wagner Almeida de 09 March 2017 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-08-30T11:30:51Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ComparacaoPlanejamentoImplantodontia.pdf: 1232836 bytes, checksum: 750df626cbebb48e9dd4ebe64d7f6f4b (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-08-30T11:31:39Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ComparacaoPlanejamentoImplantodontia.pdf: 1232836 bytes, checksum: 750df626cbebb48e9dd4ebe64d7f6f4b (MD5) / Made available in DSpace on 2018-08-30T11:31:39Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_ComparacaoPlanejamentoImplantodontia.pdf: 1232836 bytes, checksum: 750df626cbebb48e9dd4ebe64d7f6f4b (MD5) Previous issue date: 2017-03-09 / O propósito desta pesquisa foi avaliar a concordância intra examinadores no planejamento da instalação de implantes com base no exame radiográfico panorâmico e tomografia computadorizada de feixe cônico (TCFC). A pesquisa foi um estudo retrospectivo, não probabilístico por amostra de conveniência conduzida a partir de 34 pacientes, na qual foram avaliadas radiografia panorâmica e TCFC. A amostra utilizada neste estudo foi composta de 76 áreas edentulas, com um ou múltiplos espaços em diferentes regiões da maxila e mandíbula, que realizaram a instalação de implantes. Os critérios de inclusão foram: pacientes atendidos no período de 2013 a 2015; pacientes que realizaram radiografia panorâmica e TCFC; prontuários com a ficha clínica de planejamento; planejamentos discutidos entre alunos e professores antes do procedimento cirúrgico. Os planejamentos radiográfico e tomográfico foram comparados com o realizado na ficha clínica do paciente. Os avaliadores responderam um questionário com a indicação da área a ser planejada e tipo de implante, de acordo com um catálogo interativo. Os dados foram analisados inicialmente de forma descritiva, e aplicado o coeficiente de correlação intraclasse (CCI), o qual descreve a semelhança entre os valores. O nível de significância foi fixado em 5%. Os resultados mostraram que no planejamento radiográfico, a avaliação da reprodutibilidade utilizando o CCI, os valores observados foram considerados de média para boa na região posterior superior. No planejamento tomográfico, a altura anterior superior coincidiu com o planejamento cirúrgico inicial; na avaliação dos planejamentos dos posteriores superiores e altura do posterior inferior, os CCI encontrados foram considerados satisfatórios. Os resultados permitiram concluir que houve discordâncias intra examinadores no planejamento dos implantes inicial e tomográfico. A tomografia computadorizada de feixe cônico deve ser utilizada nos planejamentos de implantes. / The aim of this research was to evaluate the intra-examiner agreement in the planning of implant planning with panoramic radiography and cone beam computed tomography (CBCT). The research was a retrospective study of the 34 patients, in which panoramic radiography and CBCT were evaluated. The sample used in this study was 76 edentulous sites, with one or multiple spaces in different regions of the jaws, which performed the installation of implants. Inclusion criteria were patients attend in the period from 2013 to 2015, with panoramic radiography and CBCT, with the clinical planning, and discussed between students and teachers before the surgical procedure. The follow up of the patients who did not attend the inclusion were excluded. The radiographic and tomographic planning was compared with clinical planing. The experts answered a questionnaire with the indication of the area to be planned and type of implant, according to an interactive catalog. The data were analyzed in a descriptive statistic, and the intraclass correlation coefficient (ICC) was applied to evaluate the similarity between the measurements of the width and length of the implants by the computerized planning and the initial planning. The level of significance was 5%. The results showed that in the radiographic planning, the evaluation of the reproducibility using the CCI, the observed values were considered from average to good in the posterior maxillary. In tomographic planning, the anterior maxillary height coincided with the initial surgical planning; In the evaluation of the plans of the posterior maxillary and height of the posterior mandible, the CCI found were considered satisfactory. It was concluded that there were intra-examiner disagreements in the planning of the initial and tomographic implants. Cone beam computed tomography should be used in implant planning. / UFPA/ICS/FOUFPA
35

Software anatomia em radiografias panorâmicas: avaliação do método de ensino-aprendizado em Odontologia. / Panoramic radiographic anatomy software: evaluation of the teaching and learning method in Dentistry.

Ávila, Maria Amelia Gonçalves de 04 August 2004 (has links)
Objetivos: Desenvolver um programa de computador sobre anatomia em radiografias panorâmicas; analisar a opinião de peritos a respeito do software como método de ensino-aprendizado; analisar a aceitação do método proposto, pelos alunos do 2 0 , 3 0 e 4 0 anos de graduação da Faculdade de Odontologia da Universidade Federal de Goiás. Métodos: O software elaborado resultou em um programa tutorial multimídia interativo, estruturado em módulos, compostos dos seguintes temas: formação da imagem na técnica panorâmica, seqüência para interpretação radiográfica, anatomia radiográfica em panorâmicas, jogos e avaliação. Após a conclusão do programa, aplicou-se um questionário a 56 entrevistados (10 professores Doutores em Radiologia, denominados peritos, e 46 alunos de graduação) com a finalidade de avaliar o software como método de ensino-aprendizado. Resultados: As respostas foram analisadas por meio de análise estatística descritiva e verificou-se que: 100% dos avaliadores não fariam qualquer modificação no layout, navegação e conteúdo do módulo de anatomia radiográfica, objetivo central do software; 98% dos alunos e 60% dos peritos aprovaram as imagens desse mesmo módulo. 100% dos entrevistados gostariam de ter mais acesso a softwares educacionais e afirmaram que o programa apresentou-se explicativo e de fácil entendimento. 100% dos peritos declararam que o programa atingiu todos os objetivos propostos e se constitui de um método de ensino-aprendizado válido. Conclusão: O programa foi amplamente aceito pela população 13 pesquisada, tornado sua aplicação factível e pertinente como método de ensino-aprendizado / Objectives: To develop a software about panoramic radiography; to analyze professors opinions about the software as a teacher and learning method; to analyze graduation students - 2 0 , 3 0 and 4 0 levels / Dentistry Scholl of Goiás / Brazil - acceptation of the method. Methods: The software was developed, resulting in a multimedia tutorial containing pages about panoramic technique, interpretation sequences, panoramic radiographic anatomy, games and tests. After the completing said program, a questionnaire was applied to ten professors PhDs in Radiology, denominated experts, and 46 dental graduating students, with the purpose to analyze their opinions about the program as a teaching and learning method. Results: The answers was analyzed descriptively, and it could be observed that, 100% of experts wouldn’t make any alteration on the layout, navigation and texts in the most important part of the program, that is panoramic radiography anatomy; 98% of the students and 60% of the experts approved the images of the refereed modulus. 100% of the interviewed would like to have more educational software, and declared that the program was clear and easily understanding. 100% of the experts affirmed that the program reached all objectives proposed and can be considered as a valid teaching and learning method Conclusion: The program interested and was great accepted by the interviewed population, becoming completely feasible and pertinent the application of the said instrument as a teaching and learning method
36

Evolución de la radiología dental intraoral tras la instauración de la nueva legislación de control de calidad

Martínez Beneyto, Yolanda 13 June 2003 (has links)
Se estudian 7.176 informes oficiales de control de calidad de instalaciones de radiodiagnóstico dental pertenecientes a clínicas odontológicas que utilizan algún tipo de aparato de radiología intraoral. El estudio evolutivo corresponde a las cinco primeras revisiones de dichas instalaciones como consecuencia de la nueva normativa en la que se establecen las obligaciones que deben cumplir este tipo de instalaciones (1997-2001). Los resultados exponen un análisis cuantitativo de los parámetros, recogidos en dichos informes, con especial referencia a las características fIsicas (kVp, mA. filtración, colimador, longitud del disparador), así como las desviaciones detectadas en su funcionamiento. Se determinan las características del proceso de obtención de las imágenes radiológicas en dichas instalaciones (tipo revelado, control de tiempos de revelado, renovación de líquidos, tipo película radiogrifica, almacenamiento y caducidad de la película) y la dosis media de radiación ionizante empleada en las mismas para obtener la imagen radiológica de una misma pieza dental en las condiciones de trabajo habituales en cada una de las salas. Todo ello en su proceso evolutivo durante los cinco años posteriores a la instauración de la normativa de control de calidad. En general, los resultados obtenidos muestran una disminución del 18.75 % en las dosis medias administradas durante estos cinco años de estudio. El 97.98 % de las instalaciones radiológícas dentales estudiadas emplean dosis iguales o inferiores a 7 mGy para la realización de la exploración analizada y que corresponde a la dosis máxima de referencia recomendada en radiología intraoral. Sin embargo, sólo el 72.79% de las instalaciones radiológícas podrían llegar a cumplir todas las recomendaciones de la Unión Europea sobre las características de funcionamiento de estos equipos. Aunque el grado de cumplimiento de las recomendaciones oficiales sobre protección radiológíca no es satisfactoria. se han observado mejorías significativas en la actuación radiológíca dental por parte del profesional a lo largo de estos cinco años de evolución. Por ello, la instauración de la normativa legal esta produciendo una mejoría lenta pero progresiva de la actuación dental en España. / ' A total of 7.176 official reports on dental surgeries of cIinics in Spain are analysed. Tbe study covered the period 1997 to 2001 as consecuence of the entry into force of a new Royal Decree and dental surgeries have to undergo an annual control of quality. Tbe results shows a quantitative análisis of the variables studied in the ~ oficial reports, particu1ar1y physical characteristics of the X-ray equipments (kVp, mA, filtration thickness, collimator, lenth of tube), besides anomalies in their correct way of working. Processing of film characteristics (type of processing, control in processing time, renewal of liquids, type of film, storage and film expiration) and mean dose of ionizaing radiation are determined in habitual conditions. This study have been carried out during the 5 years following the introducction of the EU norm concerning radiological quality control .In general. the mean dose received by patients fell during the 5 years studied by 18.75 %. Meanwhile, the 97.98 % of equipments fulfil1ed the EU recommendation and did not excede 7 mGy on average per shot. However, only the 72.79 % of dental radiological equipments could follow the UE recommendations on a correct way of working. Although EU recommendations concerning radiological protection in dental clinics are not met in all cases, it have been detected significant improvements in professional behaviour during this five years of study. The establishment of the new legislation has led a gradual improvement in Spanish dental radiology practices.
37

Análise densitométrica digital do processo de reparo em dentes de rato reimplantados

Giovanini, Ellen Greves [UNESP] 30 November 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-11-30Bitstream added on 2014-06-13T20:13:38Z : No. of bitstreams: 1 giovanini_eg_me_araca.pdf: 1544057 bytes, checksum: 1b518f21ba8bc63249a3f29eb78ba402 (MD5) / A avulsão dentária é caracterizada pelo completo deslocamento do dente do seu alvéolo e a melhor forma de tratar um dente avulsionado é o seu reimplante. Mesmo diante das melhores circunstâncias os reimplantes tardios falham devido à reabsorção radicular que é detectada apenas durante a avaliação radiográfica. A imagem digital surgiu como um recurso diagnóstico rápido e de fácil utilização sendo considerada precisa. Para diminuir a variabilidade de interpretação é sugerida a análise radiográfica quantitativa por meio da densidade radiográfica. O propósito deste trabalho foi analisar comparativamente o processo de reparo do reimplante dental em ratos utilizando a análise densitométrica no sistema digital Digora. Foram utilizados 30 ratos machos, divididos em 3 grupos de 10 animais, que tiveram seu incisivo superior direito extraído e tratado da seguinte forma: grupo I - reimplante imediato, grupo II - reimplante tardio sem tratamento e o grupo III - reimplante tardio com tratamento da superfície radicular utilizando raspagem do ligamento e fluoreto de sódio. Os animais foram sacrificados após 60 dias do ato operatório, suas maxilas foram separadas e as imagens radiográficas obtidas de forma que sobre cada placa óptica ficassem as duas hemimaxilas (tratada e controle), o penetrômetro de alumínio e a identificação. Foram realizadas medidas de densidade em áreas padronizadas no sistema Digora. Os valores densitométricos encontrados foram submetidos à análise de variância e teste de Tuckey, e análise não paramétrica do número de áreas de reabsorção. Podemos concluir que a análise densitométrica constitui um importante exame complementar para o acompanhamento dos reimplantes uma vez que permitiu a detecção de reabsorção radicular em todos os grupos, cuja ordem decrescente de envolvimento foi o grupo do reimplante tardio sem tratamento... / The dental replanted has been considered the best treatment of the tooth avulsion, which is characterized by complete alveolar dislodgment of the tooth. Despite of the adequate clinical situations, the delayed replantation fails due to the root resorption that is detected during the radiographic evaluation. The use of the digital image represent a fast and easy diagnostic resource, furthest more precise. The quantitative radiographic analysis has been suggested to reduce the interpretation variability through the radiographic density. The purpose of this work was to analyze the process of repair of the dental replanted using the digital densitometry in the Digora system. The 30 male rats were divided in 3 groups of 10 animals, and their right superior incisor were extracted and treated agreement with their group: group I - immediate replanted, group II - delayed replanted without treatment and the group III - delayed replanted with treatment of the root surface using fluoride of sodium. The animals were sacrificed after 60 days operative act, your jawbones were separate and the radiographic images obtained so that on each optical plate were the two jawbones (treated and control), the aluminum step wedge and the identification. The radiographic density of radicular standardized area in Digora system was measured. The densitometric values were submitted to the variance analysis and test of Tuckey and analysis non parametric of the number of areas root resoption. We can end that digital densitometry analysis it an important complementary for replanted evaluation once it allowed the detection of root reabsorption in all of the groups, whose decreasing order of involvement was the group of the delayed replanted without treatment, following for the delayed replanted with treatment and last the immediate replanted.
38

Avaliação dos efeitos do resveratrol sobre o tecido ósseo de ratas ovariectomizadas

Fabricio, Victor 06 May 2014 (has links)
Made available in DSpace on 2016-06-02T19:23:00Z (GMT). No. of bitstreams: 1 5830.pdf: 3124907 bytes, checksum: 55c12c9ea3515d048b2237215c49333a (MD5) Previous issue date: 2014-05-06 / Financiadora de Estudos e Projetos / Resveratrol (trans 3,5,4 'trihydroxystilbene) is a polyphenol found in some plants and fruits. There are indications that it may be associated with the prevention of osteoporosis due to its action similar to a SERM (Selective Estrogen Receptor Modulators), a substance used to treat osteoporosis (among other diseases) in women whose use of hormone replacement therapy does not is indicated. However, more specific information about their effect in various quotas of bone tissue is still scarce. The aim of this study was to evaluate the ability of resveratrol to protect against bone changes characteristics of estrogen deficit in young adult ovariectomized rats. Were utilized 30 animals (Wistar rats) distributed into 3 groups: intact group (INT) with 10 intact animals, ovariectomized group (OVX) with 10 ovariectomized animals treated with a saline and dimethylsulfoxide (DMSO) solution, ovariectomized + resveratrol group (OVX + RES) with 10 ovariectomized animals treated with a resveratrol, saline and DMSO solution [0.7 mg/kg BW (body weight)], 7 times a week, for 12 weeks. Biometric, biophysical, biomechanical, microtomographical and radiographic density parameters were analyzed from bones with higher cortical (femur) and trabecular quota (vertebrae). The biomechanical properties of femurs were obtained by the three-point bending test and the lumbar vertebrae obtained by bone compression test. Lumbar vertebrae were used to perform the microtomographical analysis and radiographic density analysis. The ovariectomized rats gained more body weight and had lower bone density and radiographic density, and also showed reduction of microtomographical parameters when compared to the intact group. The biomechanical parameters of femurs did not change in neither group. The animals treated with resveratrol did not shown decrease in microtomographical parameters and bone density of the vertebrae as the untreated group. Therefore, the results suggest resveratrol as a potential protector of ovariectomy induced spoliation of bone tissues with greater trabecular quota. / Resveratrol (trans 3,5,4 -trihidroxiestilbeno) é um polifenol encontrado em algumas plantas e frutos. Há indícios de que ele possa ser associado à prevenção da osteoporose devido a sua ação similar a de um SERM (Selective Estrogen Receptor Modulators), substância utilizada para tratamento da osteoporose (entre outras doenças) em mulheres cujo o uso da Terapia de Reposição Hormonal não é indicado. Entretanto, informações mais específicas sobre o seu efeito em diferentes contingentes do tecido ósseo ainda são escassas. O objetivo deste estudo foi avaliar a capacidade do resveratrol de proteger contra as alterações ósseas características da deficiência de estrógeno em ratas adultas jovens ovariectomizadas. Foram utilizados 30 animais (ratas Wistar) distribuidos em 3 grupos: grupo intacto (INT) com 10 animais intactos, grupo controle ovariectomizadas (OVX) com 10 animais ovariectomizados tratados com uma solução de salina e Dimetilsulfóxido (DMSO), grupo ovariectomizadas + resveratrol (OVX + RES) com 10 animais ovariectomizados tratados com uma solução de resveratrol, salina e DMSO intraperitonealmente [0,7 mg/kg MC (massa corpórea)], 7 vezes por semana, por 12 semanas. Foram analisados os parâmetros biométricos, biofísicos, biomecânicos ósseos, microtomográficos e de densidade radiográfica de ossos com maior contingente cortical (fêmures) e trabecular (vértebras). As propriedades biomecânicas dos fêmures foram obtidas pelo teste de flexão a três pontos e das vértebras lombares obtidas pelo teste de compressão óssea. Foram utilizadas vértebras lombares para a realização da análise microtomográfica e de densidade radiográfica. As ratas ovariectomizadas apresentaram maior ganho de massa corporal e diminuição da densidade óssea e densidade radiográfica, além de redução dos parâmetros microtomográficos quando comparadas ao grupo intacto. Os parâmetros biomecânicos dos fêmures não sofreram alteração em nenhum dos grupos. Os animais tratados com resveratrol não apresentaram a diminuição dos parâmetros microtomográficos e de densidade óssea das vertebras como os não tratados. Portanto, os resultados apontam o resveratrol como potencial protetor do tecido ósseo com maior contingente trabecular da espoliação induzida pela ovariectomia.
39

Método computacional automático para correção do efeito \"heel\" nas imagens radiográficas / An automatic computational method for correction of the heel effect in radiographic images

Marcelo Zanchetta do Nascimento 18 March 2005 (has links)
O diagnóstico radiográfico é baseado na análise das diferenças das densidades ópticas (DO) do filme, que deveriam ser provocadas apenas pelas estruturas anatômicas do paciente. Entretanto, a intensidade do feixe de raios X não é uniforme devido a um efeito intrínseco do equipamento de aquisição de imagem, conhecido como efeito \"heel\". Estas variações prejudicam tanto a análise visual quanto o processamento computacional (CAD) das pequenas estruturas anatômicas. O presente trabalho apresenta um método computacional que corrige as diferenças de densidades ópticas produzidas na radiografia pelo efeito \"heel\". Esse método foi implementado utilizando ambiente de programação Delphi, rotinas em C e Matlab. O método simula a distribuição da intensidade ao longo do campo de radiação, determinando o caminho de absorção que os fótons sofrem dentro do alvo utilizando os modelos de Kramers e Fritz Livingston. Calcula a correlação espacial entre a radiografia e a imagem simulada, localizando o eixo anodo/catodo e o centro do campo nas duas imagens, empregando a função de correlação estatística de Pratt e a função de mapeamento de Zitová e Flusser. Calcula tanto os percentuais de radiação recebidos para cada ponto simulado em relação à radiação ao centro do campo, quanto os percentuais dos níveis de cinza de cada pixel da radiografia e corrige esse valor em função do correspondente na simulação. O algoritmo desenvolvido permitiu determinar a posição do centro do campo de radiação com precisão em torno de 1% e eliminou aproximadamente 90% do efeito \"heel\" na radiografia permitindo que os objetos apresentassem densidades ópticas coerentes com suas absorções específicas. Um estudo preliminar mostrou que esse método poderá ser utilizado como pré-processamento dos sistemas CAD. / The radiographic diagnosis is based on the analysis of the film optical density differences that should be created only by the patient anatomical structures. However, the intensity of the x-ray beam is not uniform due to an intrinsic effect to the image acquisition equipment, known as heel effect. These variations damage the visual analysis as well the (CAD) computer processing of the small anatomical structures. The current work presents a computer method that corrects the optical densities differences generated in the radiography by heel effect. This method was implemented using Delphi Programming Environment, routines in C and Matlab. The method simulates the intensity distribution along the radiation field, determining the absorption path that photons suffer inside the target using the models of Kramers and Fritz and Livingston. It calculates the space correlation between the radiography and the simulated image, determining the anode/cathode axis and the field center in the two images, using the statistics function of Pratt and the mapping function of Zitová and Flusser. It calculates as much the received radiation, percentage for each simulated point in relation the field center radiation, as the gray scales percentage of each radiography pixel and corrects their values as function of the correspondent in the simulation. The developed algorithm has allowed to determine the center position of the radiation field with about 1% precision and approximately eliminated 90%of the heel effect in the radiography, allowing the objects to present optical densities coherent with their specific absorptions. A preliminary study has showen that this method can be used as preprocessing of CAD systems.
40

Software anatomia em radiografias panorâmicas: avaliação do método de ensino-aprendizado em Odontologia. / Panoramic radiographic anatomy software: evaluation of the teaching and learning method in Dentistry.

Maria Amelia Gonçalves de Ávila 04 August 2004 (has links)
Objetivos: Desenvolver um programa de computador sobre anatomia em radiografias panorâmicas; analisar a opinião de peritos a respeito do software como método de ensino-aprendizado; analisar a aceitação do método proposto, pelos alunos do 2 0 , 3 0 e 4 0 anos de graduação da Faculdade de Odontologia da Universidade Federal de Goiás. Métodos: O software elaborado resultou em um programa tutorial multimídia interativo, estruturado em módulos, compostos dos seguintes temas: formação da imagem na técnica panorâmica, seqüência para interpretação radiográfica, anatomia radiográfica em panorâmicas, jogos e avaliação. Após a conclusão do programa, aplicou-se um questionário a 56 entrevistados (10 professores Doutores em Radiologia, denominados peritos, e 46 alunos de graduação) com a finalidade de avaliar o software como método de ensino-aprendizado. Resultados: As respostas foram analisadas por meio de análise estatística descritiva e verificou-se que: 100% dos avaliadores não fariam qualquer modificação no layout, navegação e conteúdo do módulo de anatomia radiográfica, objetivo central do software; 98% dos alunos e 60% dos peritos aprovaram as imagens desse mesmo módulo. 100% dos entrevistados gostariam de ter mais acesso a softwares educacionais e afirmaram que o programa apresentou-se explicativo e de fácil entendimento. 100% dos peritos declararam que o programa atingiu todos os objetivos propostos e se constitui de um método de ensino-aprendizado válido. Conclusão: O programa foi amplamente aceito pela população 13 pesquisada, tornado sua aplicação factível e pertinente como método de ensino-aprendizado / Objectives: To develop a software about panoramic radiography; to analyze professors opinions about the software as a teacher and learning method; to analyze graduation students - 2 0 , 3 0 and 4 0 levels / Dentistry Scholl of Goiás / Brazil - acceptation of the method. Methods: The software was developed, resulting in a multimedia tutorial containing pages about panoramic technique, interpretation sequences, panoramic radiographic anatomy, games and tests. After the completing said program, a questionnaire was applied to ten professors PhDs in Radiology, denominated experts, and 46 dental graduating students, with the purpose to analyze their opinions about the program as a teaching and learning method. Results: The answers was analyzed descriptively, and it could be observed that, 100% of experts wouldn’t make any alteration on the layout, navigation and texts in the most important part of the program, that is panoramic radiography anatomy; 98% of the students and 60% of the experts approved the images of the refereed modulus. 100% of the interviewed would like to have more educational software, and declared that the program was clear and easily understanding. 100% of the experts affirmed that the program reached all objectives proposed and can be considered as a valid teaching and learning method Conclusion: The program interested and was great accepted by the interviewed population, becoming completely feasible and pertinent the application of the said instrument as a teaching and learning method

Page generated in 0.3895 seconds