• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 99
  • 10
  • 10
  • 10
  • 10
  • 8
  • 2
  • 2
  • Tagged with
  • 102
  • 102
  • 56
  • 54
  • 48
  • 20
  • 18
  • 16
  • 15
  • 13
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência de diferentes meios de digitalização de radiografias na avalição de cáries proximais / Comparative performance of indirect digitized radiographs for detecting approximal caries

Claudio Roberto Gaião Xavier 26 October 2007 (has links)
Avaliar a influência no diagnóstico de cáries proximais das imagens geradas por dois escâneres e quatro máquinas fotográficas digitais, em formato JPEG e TIFF, e comparar o desempenho destes equipamentos ao das radiografias convencionais em relação à presença e profundidade de lesões de cárie proximais. 56 dentes extraídos foram radiografados com filme Kodak Insight em um aparelho de raios X Yoshida Kaycor, operando com 70kv e 7mA, com tempo de exposição de 0,40s. As radiografias resultantes foram digitalizadas pelos escaneres CanonScan e Genius ColorPage, e máquinas fotográficas digitais Canon Powershot G2, Canon RebelXT, Nikon Coolpix 8700 e Nikon D70s, nos formatos JPEG e TIFF. As radiografias convencionais e as imagens digitais obtidas foram avaliadas por três examinadores em duas sessões de observação. Classificaram a presença de acordo com uma escala de três níveis e a profundidade de acordo com uma escala de três níveis, quando julgassem que havia lesão. Os dentes foram seccionados no sentido mésiodistal e observados ao microscópio em luz polarizada com aumento de 10x, para a verificação da presença e profundidade da lesão de cárie. Foram determinados concordância intra e interexaminadores, probabilidade de não diagnóstico, sensibilidade, especificidade e acurácia para cada equipamento, em ambos os formatos, e para as radiografias convencionais. Os resultados foram submetidos à análise de variância a dois critérios, demonstrando que não houve diferenças estatisticamente significantes entre os formatos. A concordância intraexaminadores foi de moderada a satisfatória, e a interexaminadores de regular a moderada. A probabilidade de não diagnóstico variou de 1,34% (Convencional) a 52,83% (Escaner CanonScan/JPEG). A sensibilidade variou de 0,24 (Canon RebelXT/JPEG) a 0,53 (Convencional), a especificidade de 0,93 (Nikon Coolpix/JPEG; Canon Powershot/TIFF; Cânon RebelXT/JPEG e TIFF) a 0,97 (Escaner CanonScan/TIFF e JPEG), e a acurácia variou de 0,82 (Canon RebelXT/JPEG) a 0,91 (Escaner CanonScan/JPEG). O teste de proporções indicou diferenças estatisticamente significantes para o Escaner CanonScan, para ambos os formatos, quando comparado aos demais equipamentos e à radiografia convencional. Foi possível concluir que os formatos não influenciaram o desempenho no diagnóstico de cárie para qualquer equipamento usado. O Escaner CanonScan apresentou o pior desempenho e não se mostrou adequado para digitalização de radiografias para o diagnóstico de lesões de cárie. / To evaluate the performance of conventional and indirect digital radiography and the effect of JPEG and TIFF file formats for detecting proximal surface caries. Fifty-six extracted teeth were mounted in blocks and radiographed with Insight conventional film. Films were digitized by two flatbed scanners (Canon CanonScan and Genius ColorScan) and four digital cameras (Canon Powershot G2, Canon Rebel XT, Nikon Coolpix 8700 and Nikon D70), in both JPEG and TIFF file formats. Three observers recorded the presence and depth of caries on 112 proximal surfaces for the conventional and digitized radiographs. They scored lesion presence in a 3-point confidence scale and depth on another 3-point scale. Radiographs were evaluated twice. The observer\'s scores were compared with the results from a histological examination. Intra-observer agreement was moderate to good and interobserver agreement was fair to moderate. Sensitivities varied from 0.24 (Canon RebelXT/JPEG) to 0.53 (Convencional) and specificities from 0.93 (Nikon Coolpix/JPEG; Canon Powershot/TIFF; Canon RebelXT/JPEG e TIFF) to 0.97 (Escaner CanonScan/TIFF e JPEG). The accuracy varied from 0.82 (Canon RebelXT/JPEG) to 0.91 (Escaner CanonScan/JPEG). Images from CanonScan, both JPEG and TIFF, showed significant statistically differences compared with digital radiographs from the others devices and conventional film radiographs. File formats did not influences the detection of proximal caries. Digitizing conventional radiographs using the scanner CanonScan did not produce images of diagnostic quality.
22

Avaliação dos recursos de mensuração em diferentes sistemas de radiografia digital / Evaluation of the mensurement resources in different systems of digital x-ray

Hernandez, Angelica Maria 09 March 2009 (has links)
Os avanços tecnológicos na área de radiologia digital proporcionam a cada dia novas informações e aplicações de seus sistemas, tornando-se assim ferramenta indispensável para a comunicação e administração de informações entre profissionais e pacientes. A proposta neste estudo foi comparar o fator de correção da ferramenta de medida de três diferentes sistemas de radiografia dentária digital, em maxila de crânios secos, na região de pré-molares, onde existe a influência natural de ângulos verticais, para avaliar o grau de confiabilidade da ferramenta de mensuração, com os padrões de calibração, quando estas medidas forem realizadas na maxila. Para este estudo foram selecionados 10 pré-molares superiores, os quais foram extraídos de seus alvéolos para obtenção do Padrão Ouro (PO) com auxílio de um paquímetro digital. Padrões metálicos foram utilizados para a realização das medidas calibradas, de 5mm e de 10mm, estes localizaram-se sob a superfície dos elementos dentários selecionados (SD) e em outra etapa da pesquisa sob o acetato sem a emulsão de prata de uma película radiográfica (PR). Três sistemas de radiografia digital realizaram a captura da imagem, em seus respectivos softwares realizou-se as medidas: a) sem calibração, b) com padrão de calibração de 5mm e c) com padrão de calibração de 10mm. Quatro observadores previamente instruídos realizaram as medidas. Os resultados foram submetidos a analise estatística de ANOVA seguida pelo método de Tukey a 5%, se obteve diferenças estatísticas, as quais representaram. O tamanho e a localização do padrão metálico interferiram nos resultados; não houve diferença entre as medidas inter-observadores; o software DBSWIN (VistaScan) e VixWin PRO (Visualix) foram os que apresentaram maior diferença entre as medidas. / The technological progresses in digital radiology provide every day new information and applications of this systems, become an indispensable tool for the communication and administration of information among professionals and patient. The aim of this study was compare the correlation factor of the measure tool on three different systems of digital dental x-ray, in maxilla of dry craniums, in the area of pre molars, where the natural influence of vertical angles exists, to evaluate the degree of reliability of the measure tool, with the patterns of arranged calibration in different local, when these measured they be accomplished in the maxilla. For this study 10 superior pre molars was selected, which were extracted of its alveoli for obtaining the Gold Standard (GS) with aid of a digital pachymeter. Metallic patterns were used for the accomplishment of the gauged measures, of 5mm and of 10mm, these were located under the surface of the elements dental selects (SD) and in other stage of the research under the acetate without the emulsion of silver of a film (PR). Three systems of digital x-ray accomplished the capture of the image in its respective softwares, they took place the measures: a) without calibration, b) with pattern of calibration of 5mm and c) with pattern of calibration of 10mm. 4 observers previously well educated accomplished the measures. The results were submitted an statistics analyzes ANOVA proceeded by the method of Tukey at 5%, it was obtained statistical differences. The length and the location of the standard metallic step in on the results; there was no difference among the observers measures; the software DBSWIN (VistaScan) and VixWin PRO (Visualix) have been presented more difference among the measures.
23

Estudo radiográfico digital e densitométrico em mandíbulas de suínos, submetidas a osteotomia com brocas de alta e baixa rotação, com refrigeração líquida /

Monti, Lira Marcela. January 2005 (has links)
Orientador: Alvimar Lima de Castro / Banca: Alexandre Vieira Fernandes / Banca: Mário Jefferson Quirino Louzada / Resumo: Avaliou-se, por meio de exames radiográficos digitais e densitométricos, a influência do tipo de instrumento rotatório para corte, no processo de reparação óssea após osteotomias em mandíbula de suíno em tempos controlados. Foram utilizados para o estudo oito suínos da raça Large White, com peso corpóreo inicial variando de 25 a 30 Kg. Dois cortes transversais do meio à base de mandíbula direita foram realizados, um por meio de instrumento rotatório de alta rotação e o outro pela ação da baixa rotação, ambos com irrigação líquida. Após períodos pré-estabelecidos (7, 28, 60 e 90 dias) os animais foram sacrificados e suas mandíbulas retiradas para estudos radiográficos digitais diretos e indiretos, pelo sistema DIGORA e ODR e de densitometria óptica por imagens radiográficas pelo sistema CROMOX. Nos períodos iniciais (7 e 28 dias) as densitometrias foram maiores na região das osteotomias realizadas com alta rotação e nos períodos finais (60 e 90 dias) as densitometrias foram maiores nas osteotomias feitas com baixa rotação, indicando uma melhor reparação óssea final quando do uso de baixa rotação. A análise qualitativa do processo de reparação foi feita pelo sistema ODR, que possibilitou a obtenção de imagens digitais tridimensionais e coloridas, permitindo comparação das espessuras ósseas com as de uma cunha de alumínio, evidenciando que aos sessenta dias a reparação óssea estava aparentemente completa. Os histogramas do DIGORA apontaram valores de médias de nível de cinza nas áreas de osteotomia, evidenciando uma maior quantidade de tons de cinza nas osteotomias de alta rotação nos primeiros tempos, e nas osteotomias com baixa-rotação nos tempos finais. / Abstract: It was evaluated, through digital and densitometric radiographic exams, the influence of the type of rotating instrument for cut, in the process of bony repair after osteotomy in swine jaw in controlled times. They were used for the study eight Large White swines, with initial corporal weight varying from 25 to 30 Kg. Two traverse cuts of the middle to the base of right jaw were accomplished, one through rotating instrument of high rotation and the other for the action of the low rotation, both with liquid irrigation. After established periods (7, 28, 60 and 90 days) the animals were sacrificed and your mandibles retired for direct and indirect digital radiografic studies, for the DIGORA and ODR systems and of optical densitometry for radiographic images for the CROMOX system. In the initial periods (7 and 28 days) the densitometry were larger in osteotomy areas accomplished with high rotation and in the final periods (60 and 90 days) the densitometry were larger in the osteotomy done with low rotation, indicating a better final bony repair when of the use of low rotation. The qualitative analysis of the repair process was made by the ODR system, that made possible obtaining three-dimensional and colored digital images, allowing comparison of the bony thickness with the one of a wedge of aluminum, evidencing that to the sixty days the bony repair was apparently complete. The histograms of DIGORA pointed values of the averages of ash tones in the osteotomy areas, evidencing a larger amount of ash tones in the osteotomy of high rotation in the first times, and in the osteotomy with low-rotation in the final times. / Mestre
24

Surto de crescimento puberal: relação entre mineralização dentária, idade cronológica, idade dentária e idade óssea : método radiográfico /

Moraes, Mari Eli Leonelli de. January 1997 (has links)
Orientador: Edmundo Médici Filho / Banca: Jorge Abrão / Banca: Frab Norberto Boscolo / Banca: Flávio Vellini Ferreira / Banca: Weber José da Silva Ursi / Resumo: Com uma amostra de 244 pacientes, sendo 112 meninos e 132 meninas, com idades de 7 a 15 anos, estudamos pelo método radiográfico, a relação entre as fases da curva padrão do surto de crescimento puberal (SCP) com as fases da mineralização dentária dos caninos, pré-molares, segundo e terceiro molares inferiores. Estudamos também a correlação entre as idades cronológica, dentária e óssea quando agrupadas de acordo com as fases do SCP. Para calcular a idade dentária, utilizamos radiografias panorâmicas, aplicando a Tabela de Nicodemo et al.114, 1992, e para calcular a idade óssea, utilizamos radiografias carpais, aplicando o método de Eklöf & Ringertz28 , 1967, pelo software Radiocef. Verificamos que existe correlação positiva alta entre as médias das idades estudadas, quando agrupadas de acordo com as fases do SCP. Quanto à mineralização dentária, verificamos que as fases mais marcantes da relação entre SCP e mineralização dentária, considerando os dois sexos agrupados, apontam no início do SCP, que o segundo molar está iniciando a formação radicular; no pico, que o canino está completando o fechamento apical; e que no fim do SCP, o canino e os pré-molares estão com os ápices fechados, mas o segundo molar está terminando a formação radicular, ainda com o ápice aberto. O fechamento apical do canino, pré-molares e segundo molar é um forte indicador de que o SCP já terminou. As curvas de crescimento elaboradas mostram que a mineralização dentária acompanha as fases do SCP, indicando que a relação entre elas é válida, e desse modo, a radiografia dentária pode ser utilizada clinicamente para verificar a época do SCP / Abstract: In this research, the relation of stages of pubertal growth spurt and stages of tooth mineralization of lower canine, first and second bicuspid, second and third molar, was investigated in 112 subjects boys and 132 girls, by radiographic method. We also studied the correlations of chronological age, dental age and skeletal age, arrange in accord of the individuals by the stages of pubertal growth spurt. The dental age was performed using the method of Nicodemo et al.114, 1992, in panoramic films, and, the skeletal age was assessed by a established computer software Radiocef, using the method Eklöf & Ringertz28, 1967, in carpals films. We found a high correlation among ages studied. The more significant stages of tooth mineralization, when the sex are considered together, shows that in the beginning of spurt, the second lower molar is beginning the root formation. At the peak the canine is accomplish the apex. At the end of spurt the apex of the canine, first and second bicuspid are closed, but the second molar is finishing the root formation, but still with the apex open. The apical closure of canine, bicuspids and second molar is a strong indicator that the pubertal growth spurt is already finished. The developmental curvs show that the chronology of tooth mineralization proceed together with the spurt's stages and can be used clinically to verify the stages of growth pubertal spurt / Doutor
25

A influência de ferramentas de visualização no desempenho da tarefa interpretativa e sua aplicação no diagnóstico de lesões dentais coronais interproximas

Vilain, Inês January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T00:49:47Z (GMT). No. of bitstreams: 0Bitstream added on 2013-07-16T18:15:43Z : No. of bitstreams: 1 175581.pdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
26

AVALIAÇÃO DA COMPRESSÃO DA IMAGEM DIGITAL DA TELERRADIOGRAFIA LATERAL NA REPRODUTIBILIDADE DA MARCAÇÃO DE PONTOS CEFALOMÉTRICOS / Evaluation of the compression of the Cephalometric Radiography digital images in the reproducibility of cephalometric Landmarks.

Duarte, Hená Elizeth Meireles 27 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Hena Elizeth1.pdf: 163468 bytes, checksum: 7331fee05880654fa8b7d97d71d3c202 (MD5) Previous issue date: 2008-02-27 / The photo-stimulable storage phosphor imaging plates sistem shows the images in the computer screen as a DICOM (digital image and comunication in medicine) format. This kind of imaging format uses a lot of memory space in the computer hard disc what turns its storage and file trasmition in the internet a dificult task. The aim of this study was to evaluate the efect of the JPEG compression in different qualities factors (100, 80 and 60) in the reproducibility of cephalometric points in lateral teleradiographies comparing with DICOM images. The sample of the study consistes of 120 digital lateral teleradiographies obtained from 30 individuals, in DICOM format. These images were converted in JPEG format. Three dentists expertized in orthodontist were calibrated and then were oriented to mark cephalometric points em each image using the XY coordinates system after random and blind the sample. This was repeated one month later. Intra-observer and interobserver reproducibility was calculated using the intra-class correlation test. Differences between the compression ratios were assessed using a one-way analysis of variance. The results showed that the points marcations were reproductible, except to the Orbital point in the X coordinate. The statisc analyse showed no difference between the files formats to each point and axis. The different JEPG qualities compression factors studied (100, 80 and 60) did not affected the reproducibility in cephalometric points marcation tested. / A imagem digital adquirida pelo sistema da placa de fósforo foto ativada é visualizada no monitor do computador em um formato denominado DICOM. Este formato ocupa muito espaço para armazenamento, o que dificulta o arquivamento e transmissão da imagem pela Internet. O objetivo deste estudo foi avaliar a influência da compressão JPEG, nos Fatores de Qualidade 100, 80 e 60 na reprodutibilidade da marcação de pontos cefalométricos em imagens de telerradiografias em norma lateral comparadas com o formato DICOM. A amostra consistiu de 120 imagens de telerradiografias em norma lateral obtidas a partir de 30 indivíduos, dos quais se obteve uma radiografia digital no formato DICOM. Essas imagens foram convertidas para o formato JPEG. Após o cegamento e randomização da amostra, três Ortodontistas calibrados marcaram a localização de 12 pontos cefalométricos em cada imagem utilizando o sistema de coordenadas X e Y. Esse procedimento foi repetido após 1 mês. A reprodutibilidade intra e inter observador foi calculada usando o teste de correlação intraclasse. Para comparação entre os grupos de compressão e DICOM na reprodutibilidade de marcação dos pontos utilizou se a Análise de Variância (ANOVA) a um critério para medidas repetidas. Os resultados mostraram que as marcações dos pontos cefalométricos foram bastante reprodutíveis, exceto para o ponto Órbita na coordenada X. Os diferentes formatos de arquivo mostraram estatisticamente iguais para cada ponto e eixo aferido. As compressões JPEG estudadas das imagens de telerradiografias em norma lateral não tiveram efeito na reprodutibilidade da marcação dos pontos cefalométricos testados.
27

Diagnóstico de cárie proximal por radiografia digital e por tomografia computadorizada de feixe cônico: estudo comparativo.

Oliveira, Luciana Soares de Andrade Freitas January 2014 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2015-07-17T19:47:19Z No. of bitstreams: 1 OLIVEIRA, Luciana Soares de Andrade Freitas.pdf: 2586827 bytes, checksum: 14a3f2e737aec17bd9871a62d83bf7a1 (MD5) / Made available in DSpace on 2015-07-17T19:47:19Z (GMT). No. of bitstreams: 1 OLIVEIRA, Luciana Soares de Andrade Freitas.pdf: 2586827 bytes, checksum: 14a3f2e737aec17bd9871a62d83bf7a1 (MD5) / FAPESB / A introdução de medidas preventivas de saúde oral levou a uma modificação nas características das lesões de cáries: elas tornaram-se menores e de crescimento mais lento. Quando localizadas em face proximal, o seu diagnóstico fica ainda mais difícil, já que não é possível uma visão direta dessa região. Busca-se, assim, estabelecer métodos de diagnóstico que permitam detectar lesões de cárie proximal em esmalte antes que seus sinais clínicos de cavitação sejam evidentes. O objetivo deste trabalho, aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da UFBA, foi o de avaliar a detecção de cárie proximal em esmalte por diferentes métodos de aquisição de imagem. Foram selecionados 60 dentes humanos para compor a amostra, 12 caninos, 24 pré-molares e 24 molares, que não deveriam apresentar cavitações ou restaurações em suas faces proximais. Eles foram montados em blocos de silicone de maneira sequencial e aleatória para compor 12 phantoms, contendo, obrigatoriamente, um canino, dois pré-molares e dois molares. Os phantoms foram radiografados utilizando-se o aparelho de raios X Expert DC e, como receptores de imagens, placas de armazenamento de fósforo (PAF) dos sistemas de imagem digital VistaScan Perio Plus e DenOptix. Para a obtenção das imagens tomográficas, foram utilizados três tomógrafos computadorizados de feixe cônico de diferentes fields of view (FOV): o Kodak 9000 3D, o 3D Accuitomo 170 e o Scanora. As imagens obtidas foram montadas em templates e avaliadas por três Radiologistas de maneira independente quanto à presença/ausência de cáries nas faces proximais. Para obter-se o padrão ouro, os dentes foram seccionados no sentido mesiodistal e avaliados em um microscópio estereoscópico. A análise dos dados foi realizada pelo teste Kappa, para avaliar-se a concordância inter- e intraavaliadores; foram também calculadas a acurácia, a sensibilidade, a especificidade e seus respectivos intervalos de confiança para cada método, sendo definidos como significativos os valores de p≤0,05. Observou-se que os métodos apresentaram uma baixa sensibilidade para o diagnóstico de cáries, tendo o Kodak 9000 3D em cortes axiais e as radiografias digitais (p>0,05) apresentado a menor sensibilidade, ao passo que o mais sensível foi o Scanora em cortes axiais (p=0,046). As radiografias digitais apresentaram comportamento semelhante (p=1,0). Entre as tomografias, o comportamento, de igual modo, foi semelhante, não se registrando diferenças nos diferentes planos do espaço (p>0,05). A especificidade dos métodos foi alta (de 89,1% a 100%), assim como a sua acurácia geral (70,8% a 79,1%). A despeito de se ter observado uma boa acurácia geral dos métodos, para testá-los em relação ao seu poder de diagnóstico de cáries deve-se levar em consideração a sua sensibilidade, isto é, sua capacidade para distinguir, entre as faces analisadas, aquelas que realmente possuem cáries. Concluiu-se que os métodos testados apresentaram baixa sensibilidade para o diagnóstico de cáries proximais, sobretudo aquelas incipientes, tendo, portanto, valor limitado para este fim. / The use of preventive techniques of oral health has led to changes in caries’ characteristics: they became smaller and their growth, slower. Whenever its development occurs on a proximal surface, its diagnosis is more difficult, because it forbids a direct view of the region. Recent researches are focused on the development of new diagnostic methods that enables proximal enamel caries detection before the clinical signs of cavitation occurs. The aim of this study is to evaluate the detection of proximal caries using different methods of image acquisition. This study was approved by the Research Ethics Committee of UFBA Dentistry School. 60 human teeth without cavitations and restorative materials in their proximal surface were selected as a sample: 12 canines, 24 premolars, and 24 molars. They were mounted randomly, however respecting their natural order in 12 silicon blocks. Each one of the 12 phantoms had one canine, two premolars, and two molars. Phantoms were radiographed using an Expert DC X-ray machine, and the following images plates were used: VistaScan Perio Plus and DenOptix. To acquire the tomographic images, three conebeam computed tomographic (CBCT) machines with different Fields of View were used: Kodak 9000 3D, 3D Accuitomo 170, and Scanora. Images were mounted in templates and, were then evaluated by three oral radiologists. They should score proximal surfaces for the presence or absence of caries. A gold standard was acquired by sectioning each tooth in sagittal direction and evaluating with stereoscopic microscopy. Kappa statistic was applied to evaluate intra- and inter-rater agreement. Overall accuracy, sensibility, and specificity were also calculated. It was defined with a significant p value of p ≤ 0.05. All methods had a low sensibility in diagnosing caries. Kodak 9000 3D in axial view and digital radiographies had the lowest sensibilities (p > 0.05), and Scanora in axial view had the highest sensibility (p = 0.046). Digital radiographies showed similar behavior (p = 1.00). CBCT also had similar behavior, and differences in diagnostic sensibility were not detected whenever evaluating in axial or sagittal plans (p > 0.05). All methods had high specificities varying from 89.1% to 100%; overall accuracy was also high (70.8–79.1%). Even though the tested methods had high overall accuracy, when a method was tested for its ability in caries diagnosis, sensibility, which is its capability of detecting caries within all surfaces with caries, should not be neglected. It can be concluded that none of the tested methods showed high rates of sensibility, and so they have limited applicability to evaluate proximal caries.
28

Comparação entre a radiografia periapical digital e a tomografia computadorizada de feixe cônico na detecção de reabsorção radicular em molares decíduos

Seára, Juliana Nicolau January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-03-04T19:59:47Z (GMT). No. of bitstreams: 1 305578.pdf: 1508782 bytes, checksum: dbc22eb4f13856530fba07695a8ce1d4 (MD5) / Introdução: O objetivo deste estudo foi avaliar e comparar a acurácia da radiografia periapical digital (RPD) e da tomografia computadorizada de feixe cônico (TCFC) na detecção de reabsorção radicular em molares decíduos. Métodos: A amostra foi composta por, 43 molares decíduos superiores e inferiores, com e sem reabsorção radicular. Estes dentes foram posicionados em um crânio seco humano e obtidas as imagens das raizes pelo método radiográfico digital e tomográfico. Um examinador calibrado interpretou, inicialmente as imagens radiográficas e após 7 dias as imagens tomográficas, ambas por meio do software específico. Após a primeira avaliação das imagens o examinador repetiu o procedimento com intervalo de duas semanas. A concordância intra-examinador foi estimada pelo teste Kappa. Resultados: Kappa de 0.84 foi obtido para as avaliações radiográficas e tomográficas. Os valores da sensibilidade e especificidade da TCFC foram, respectivamente, 73,8% e 70,5%, enquanto que para RPD foram 52,1% e 65,5%, comprovando que a TCFC é o método mais indicado para visualizar reabsorções radiculares. Conclusão: Ambos os métodos RPD e TCFC são eficazes na detecção de reabsorção radicular em molares decíduos, porém a TCFC apresenta maior acurácia diagnóstica. / Introduction: The aim of this study was to evaluate and compare the accuracy of digital periapical radiography (RPD) and cone beam CT (CBCT) in the detection of root resorption in deciduous molars. Methods: The sample consisted of 43 upper and lower molars with and without root resorption. These teeth were placed in a human dry skull and the images obtained from the roots by CT and digital radiographic method. A calibrated examiner interpreted initially radiographic images and 7 days after the tomographic images, both through specific software. After the first evaluation of the images the examiner repeated the procedure with an interval of two weeks. The intra-examiner was estimated by Kappa test. Results: Kappa value of 0.84 was obtained for radiographic and tomographic evaluations. The values of sensitivity and specificity of CBCT were respectively 73.8% and 70.5%, while for RPD was 52.1% and 65.5%, proving that CBCT is the best method to visualize root resorption . Conclusion: Both RPD and CBCT methods are effective in the detection of root resorption in deciduous molars, but CBCT has higher diagnostic accuracy.
29

Lesão de cárie proximal :: avaliação radiográfica e clínica com separação dental após 3 anos da análise inicial, em dentes posteriores permanentes /

Humberto, Janaína Silva Martins January 1999 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. / Made available in DSpace on 2012-10-18T20:11:29Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T03:49:28Z : No. of bitstreams: 1 142969.pdf: 3923598 bytes, checksum: ad1263525b21a5cb4a8f34f13f824368 (MD5)
30

Estudo da erupção dos dentes caninos, primeiros e segundos premolares dos lados direito e esquerdo, pelo método radiográfico

Rocha, João Carlos da [UNESP] 27 June 1995 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:57Z (GMT). No. of bitstreams: 0 Previous issue date: 1995-06-27. Added 1 bitstream(s) on 2015-12-10T14:29:11Z : No. of bitstreams: 1 000026860.pdf: 2144269 bytes, checksum: 19d0f4d1d22e6e5601ccbbba13196e0b (MD5) / A erupção dentária é um fator que ao longo de muitos anos mereceu pesquisas para o conhecimento de suas variações. Dentre as variações, a diferença de erupção entre os lados esquerdo e direito dos arcos superior e inferior, é a que menos foi analisada detalhadamente. O autor comparou a erupção alveolar dos dentes caninos, primeiros e segundos premolares, entre os lados esquerdo e direito dos arcos superior e inferior, na faixa etária de sete a 11 anos, nos sexos masculino e feminino, pelo método radiográfico. Analisando 450 radiografias panorâmicas do arquivo da Disciplina de Radiologia do Departamento de Diagnóstico e Cirurgia da Faculdade de Odontologia do Campus de São José dos Campos - UNESP, verificou que: existe precocidade de erupção alveolar nos indivíduos do sexo feminino; a seqüência de erupção alveolar para a maxila e para a mandíbula foi - primeiro premolar, segundo premolar e canino e não existe diferença estatisticamente significante na cronologia de erupção alveolar entre os lados esquerdo e direito da maxila e da mandíbula para os dentes estudados / The tooth eruption have been studied for many years about the knowledge of its variations. From these variations the difference between the eruption of the superior and inferior archs, and also the right and left sides have been poorly analysed. The author compared the alveolar eruption of the permanents canines, first and second premolars between the right and left sides of the superior and inferior archs, from 7 and 11 years of age, in males and females, by radiographic method. By the Discipline of Radiology of the Diagnosis and surgery Departament of the School of Dentistry of São José dos Campos - UNESP, observed that: there is early eruption in female; the alveolar eruption sequence in maxillar and mandibular was: first premolar, second premolar e canino. There wasn't statiscally significant difference of the alveolar eruption between the right and left sides of maxillar and mandibular archs

Page generated in 0.0829 seconds