• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 393
  • 140
  • 74
  • 72
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 686
  • 277
  • 276
  • 276
  • 276
  • 212
  • 191
  • 190
  • 62
  • 50
  • 49
  • 48
  • 47
  • 47
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Comparação entre a tomografia computadorizada multislice e a tomografia computadorizada por feixe cônico para identificação de lesões osteolíticas simuladas na cabeça da mandíbula / Comparison between multislice computed tomography and cone beam computed tomography for assessment of simulated mandibular condyle lesions

Marques, Alexandre Perez 04 February 2010 (has links)
A articulação temporomandibular (ATM) apresenta diversas limitações quando se obtém imagens pela radiologia convencional. A tomografia computadorizada é o exame mais indicado, pela alta especificidade e sensibilidade, para o diagnóstico, planejamento cirúrgico e tratamento das suas lesões ósseas. O objetivo deste trabalho consiste na comparação entre a tomografia computadorizada (TC) multislice e a tomografia computadorizada por feixe cônico (TCFC) para avaliação de lesões ósseas simuladas na cabeça da mandíbula. Foram utilizadas 30 cabeças de mandíbulas maceradas onde foram criadas lesões esféricas, com o auxílio de brocas cirúrgicas esféricas de uso odontológico com tamanhos variados (nº 1, 3, 6), em suas cinco porções (anterior, lateral, posterior, medial, superior). As lesões foram submetidas a TC multislice (64 canais) e a TCFC, sendo avaliadas em dois programas de pós-processamento por dois observadores independentemente, sendo um deles em duas ocasiões distintas. Foram utilizados também dois protocolos de análise para exame das imagens quanto à presença ou não de perfuração: reconstrução multiplanar (axial, coronal, sagital) e cortes sagitais e coronais ao longo eixo da cabeça mandibular. Posteriormente, os resultados brutos foram comparados com as lesões presentes na mandíbula macerada (Padrão-Ouro) avaliando a proporção de acertos de cada observador, o grau de especificidade e sensibilidade dos diferentes métodos da TC e da TCFC, e a comparação intra-observador e inter-observadores. O teste z foi utilizado como método estatístico. Os resultados demonstraram não haver diferenças estatisticamente significantes entre os métodos em relação às porcentagens de concordância e que todos estes são validados. Os protocolos para visibilização da região de cabeça da mandíbula foram estabelecidos no intuito de melhorar a identificação da presença de alterações de cada porção da cabeça da mandíbula. Houve maior dificuldade na avaliação de lesões simuladas de pequena dimensão (broca 1) / There are many limitations for image acquisition using conventional radiography of the temporomandibular joint (TMJ) region. Computerized tomography (CT) scan is a better option due to its higher specificity and sensitivity for diagnosis, surgical planning and treatment of bone injuries. The purpose of this study is to compare multislice CT and cone beam computed tomography for evaluation of simulated mandibular condyle lesions. Spherical lesions were created in 30 dry mandibular condiyle with dentist drills (sizes 1, 3, and 6). Condyles were submitted by multislice (64 bits) CT and cone beam computed tomography (CBCT) using two independent software by 2 observants alone, one of them in 2 different occasions, using 2 protocols: axial, coronal and sagittal, and sagittal plus coronal slices for the mandibular condyle visualization. The raw data were compared with the dry mandible (gold standard) regarding the presence of injuries, evaluating the proportion of agreement, degree of specificity and sensitivity of the CT and CBCT and observant analysis. The z test were used as statistical methods. The results showed there are no statistically significant differences between the methods, and the whole methods are validity. It was observed the advantage of the association of axial, coronal and sagittal slices and sagittal plus coronal slices for detection of lesions in mandibular condyles. For some lesions localized in regions, protocols did not show statistically significant differences regarding the proportion of agreement. Protocols were created to improve the visualization of lesions in each region of the mandibular condyle. There was more difficult for assessment small size simulated lesions (# 1).
392

Padronização das tomadas radiográficas periapicais e panorâmicas com finalidade forense / Standards of periapical and panoramic radiographs for forensic examinations

Beaini, Thiago Leite 18 June 2010 (has links)
Existem dificuldades envolvendo as radiografias para as técnicas comparativas de identificação humana. A falta de tecidos moles, o posicionamento do crânio e dos filmes representa obstáculos freqüentes durante as perícias antropológicas. Com objetivo de padronizar e obter imagens de qualidade e reduzir adaptações, testamos exposições, barreiras e outros aspectos radiográficos para a confecção de um protocolo envolvendo radiografias periapicais e panorâmica em crânios esqueletizados. Com a utilização de um dispositivo acrílico desenvolvido para posicionar o crânio, radiografias panorâmicas em diferentes configurações de potência do aparelho foram tomadas. Posteriormente, quatro objetos foram testados para compensar a falta de tecidos moles: uma bolsa térmica, um bloco de cera sete, uma placa de aço zincado e um filme, exposto à luz e processado, que foi mantido entre a película e a tela intensificadora. Para as radiografias periapicais, filmes do tipo E speed Kodak foram expostos por tempos variando entre 0,06 a 0,8 seg nas regiões de molares e incisivos em ambos os arcos. Os filmes foram fixados por posicionadores clínicos estabilizados por um suporte confeccionado com fios metálicos. O tempo de processamento foi de 45 seg de revelação e 10 min. de fixação. As radiografias foram apresentadas a quinze profissionais, de diferentes especialidades, que escolheram os melhores resultados, concluindo que as radiografias panorâmicas com a combinação de 63 Kv e 06 mA e com dois filmes presentes no chassi apresentou melhor qualidade e praticidade. Para as periapicais as exposições de 0,64 seg. no arco superior e 0,8 seg. no arco inferior obtiveram melhor aceitação. Com os resultados obtidos somados aos dados obtidos na literatura, um protocolo foi confeccionado e anexado a essa dissertação. / There are plenty of difficulties surrounding the radiographs for the comparative techniques on human identification. The lack of soft tissue, the skulls and films positioning are a few of the obstacles faced in anthropological studies. With the objectives to standardize, producing high quality images and reducing adaptations, different exposure times, barriers and other aspects involving radiographs were tested in order to establish a protocol involving periapical and panoramic radiographs of dry skulls. With the help of an acrylic stand, specially designed to position the cranium, panoramic radiographs were primarily taken using different preset configurations, then four materials were tested to compensate for lack of soft tissue: a ice pack, a block of dental wax, a metal plate and finally a film exposed to light and processed that was left between the blank film and the intensifying screen. For the periapical radiographs, Kodak E-speed films were exposed to times from 0.06 to 0.8 second at the upper and lower molars and anterior regions. Clinical film holders were used and kept in position by a metal wire device. The processing times were 45 seconds of development and 10 minutes of fixation. The radiographs were presented to a group of fifteen dentists, of several specialties, who selected the best results and concluding that the panoramic radiographs were best taken with the 63 Kv and 06 mA configurations and two films inside the cassette. For the periapical the exposure times of 0.64 sec for the upper arch and 0.8 sec for the lower achieved the best acceptance. The presented results, allied with the data found in the literature a protocol was also prepared and attached to this research.
393

"Estudo da padronização para a determinação de pontos cefalométricos utilizados na cefalometria radiológica" / Standardization for the determination of cephalometric landmarks used in radiological cephalometric analysis

Amad Neto, Mustaphá 06 October 2004 (has links)
O objetivo nesta pesquisa foi o de avaliar quantitativamente as variações na determinação de 7 pontos cefalométricos e analisar o quanto que estes erros podem influenciar no planejamento e progressão da terapêutica ortodôntica. Foram utilizados 14 crânios macerados onde fora colocadas esferas metálicas para a demarcação dos pontos cefalométricos escolhidos. Estes crânios foram radiografados com e sem as esferas metálicas, e as grandezas cefalométricas avaliadas estatisticamente. Os resultados mostraram que a média de erro na localização dos pontos foi de 57,5% e que este desvio em termos numéricos podem levar a equívocos de planejamento que podem comprometer seriamente o resultado do tratamento com desvios em algumas medidas cefalométricas de até 4mm. As mensurações relacionadas aos pontos espinha nasal anterior, pogonio e gônio foram as que tiveram maior reprodutibilidade, porém, as medidas cefalométricas relacionadas ao ponto A mostraram que as diferenças encontradas então em torno de 4,3mm, e que a avaliação do comprimento mandibular obtida pela localização do ponto condílio, também gerou diferenças de 2,8mm em média, alterando assim substancialmente as avaliações para diagnóstico e tratamento ortodôntico e cirúrgico. / The aim of this study were to evaluate quantitatively the variations on the determination of 7 cephalometric landmarks and to analyze how these differences may influence the planning and outcome of the orthodontic treatment. Small steel balls were glued on specific sites of 14 dry skulls to represent the true anatomical landmarks. The skulls were radiographed with and without the steel balls, and the cephalometric values were submitted to statistical analysis. Results showed that the error in the localization of the landmarks was in average 57,5%. This high deviation, that reaches up to 4mm in certain cephalometric measurements, could lead to errors in treatment planning and compromise the result of any orthodontic treatment. Measurements of the Anterior Nasal Spine, Pogonion and Gonion showed the highest reproducibility, while point A showed the lowest (4,3mm). The evaluation of the mandibular length through the identification of Condyle also showed high discrepancies (2,8mm), which may alter the evaluations for orthodontic and/or surgical diagnosis and treatment.
394

Estudo do membro pélvico do avestruz: considerações anatômicas, radiográficas e histológicas da rotação tibiotársica / Study of hind limb in ostrich: anatomical, radiografic and histological considerations of the tibiotarsica rotation

Oliveira, Roselaine Ponso de 11 March 2005 (has links)
Várias doenças músculo esqueléticas foram observadas em aves de rápido crescimento, sendo o elevado peso corporal, associado a uma estrutura óssea em formação, citados como as principais causas responsáveis pela ocorrência destas doenças, resultando em disfunções do aparelho locomotor. Apesar do estudo do membro pélvico do avestruz merecer a atenção de pesquisadores desde o século XIX, tendo sido descrito no tocante à miologia, principalmente, a osteologia e o estudo radiográfico e morfológico envolvidos na RTT ainda não receberam a devida atenção. O presente trabalho teve como objetivo fazer um estudo anátomo-patológico e radiográfico das estruturas envolvidas na rotação tibiotársica, assim como estudar as alterações articulares através de artrografias e histologia fazendo uma descrição das considerações anatômicas, macroscópicas, microscópicas e radiográficas do membro pélvico do avestruz (African Black). Para este estudo foram utilizadas trinta avestruzes, com idade entre um mês a um ano de idade, apresentando deformidade de membros pélvicos uni ou bilateral. Dessa forma, será possível contribuir para o entendimento desta enfermidade, que tem causado perdas para a estrutiocultura. / Ostrich?s hind limbs study: Anatomical, radiographic and histological considerations of the tibiotarsus rotation. Many skeletal muscles diseases were observed in fast growth, been the hight body wight, to associate with a bone structure in formation citads with the principal responsible cases for ocorrence these deseases, have been disfunction of locomotor arrangment. Despite the fact that the ostrich?s hind limbs have deserved attention from researchers since the 19th century, the myological and osteological descriptions together with the radiographic and morphological study, which involves RTT, have not received any attention yet. This present research intends to make an anatomical, pathological and radiographic study of the structures involved in the tibiotarsus rotation, besides the study of the joint alterations by arthrography and histology, giving one description with anatomical, macroscopic, microscopic and radiographic considerations of the ostrich?s hind limbs. This way, it?ll be possible to contribute to the comprehension of this disease that has caused many losses on the ostrich farm.
395

Estudo experimental dos efeitos da embolização renal com partículas de trisacryl e de polivinil acetato recoberto com polivinil álcool / Experimental study of effects of renal embolization with trisacryl particles and polivinyl alcohol covered polivinyl acetate

Barbosa, Leandro de Assis 06 October 2009 (has links)
A embolização intra-arterial é rotineiramente utilizada na prática clinica como co-adjuvante pré-operatório ou controle de tumores, tratamento de malformações arteriovenosas e outras doenças vasculares. Em vários casos é realizada com uso de partículas de diferentes formas e composições. Um agente embolizante esférico e utilizado com bons resultados é o trisacryl (Embosphere®; BioSphere® Medical). Um novo agente embólico - polivinil acetato esférico cobertas com polivinil álcool (PVAc) foi desenvolvido recentemente no Brasil. Este trabalho tem objetivo de avaliar, após embolização renal, o grau de oclusão vascular, recanalização da luz vascular e a necrose da parede vascular provocados por partículas de PVAc, utilizando como parâmetro partículas de trisacryl. Setenta e nove fêmeas de coelhos do tipo albino New Zealand foram submetidas a cateterização arterial do rim direito; trinta e três animais foram embolizados com trisacryl, trinta e um com PVAc e quinze animais compuseram o grupo de simulação, tendo sido excluídos quatro animais (três trisacryl e um PVAc) devido a óbito precoce. Foram criados cinco subgrupos de seis animais, que foram sacrificados após 48 horas, 5 dias, 10 dias, 30 dias e 90 dias após a embolização. O grupo de simulação seguiu a mesma ordem temporal com três animais em cada grupo. As técnicas de coloração utilizadas foram os métodos de hematoxilina-eosina (HE) e tricrômico de Masson com observação por microscopia óptica. Os resultados mostraram diferença significativa entre o grau de oclusão vascular nos grupos de 5 dias e 10 dias e necrose no grupo de 48 horas em favor do grupo embolizado com PVAc, que apresentou reação tecidual adequada (redução volumétrica e isquemia) e menor grau de recanalização que o trisacryl / Intra-arterial embolization is often utilized in medical practice preoperatively as adjuvant in controlling tumors, treatment of arteriovenous malformations and other vascular diseases. Often times, particles of different forms and compositions are employed. trisacryl (Embosphere®; BioSphere® Medical), a spheric embolic agent, is nowadays used with very satisfactory results. However, a new embolic agent spheric polyvinyl alcohol-covered polivinyl acetate (PVAc)- has been developed in Brazil. This study evaluates the degree of vascular occlusion, vascular recanalization and the necrosis of vascular wall caused by PVAc particles, compared with trisacryl, after renal embolization. Seventy-nine female albine New Zealand rabbits underwent arterial catheterization of the right kidney; Thirty-three animals were embolized with trisacryl, thirty-one with PVAc and fifteen were kept as control group, four animals were excluded (three trisacryl and one PVAc) due to early death. Five subgroups of six animals were created. The animals in the different groups were sacrificed 48 hours, 5 days, 10 days, 30 days and 90 days after embolization. The control group was divided into subgroups of three animals, for the same period of time. Their kidneys were dyed with hematoxylin-eosin (HE) and Masson tricromic and examined using optic microscopy. The results showed a significant difference between the five-day and ten-day groups with regard to the degree of vascular occlusion, and the amount of necrosis in the forty-eight-hour group. Both findings favor the PVAc group, with adequate tissue reaction (ischemia and volumetric reduction) and less recanalization than with trisacryl
396

O ensino de f?sica das radia??es em ambientes hospitalares : avalia??o das concep??es sobre raios x com enfoque na preven??o e tecnologia

Luz, Renata Matos da 27 March 2013 (has links)
Made available in DSpace on 2015-04-14T14:13:00Z (GMT). No. of bitstreams: 1 449340.PDF: 2706078 bytes, checksum: 7acc6da0eeca8a931790b363b0e1b8b8 (MD5) Previous issue date: 2013-03-27 / This paper aimed to identify the conceptions of professionals with technical degree in radiology, operating in the labor market, concerning the field of Modern Physics concepts related to their profession as well as the value they give to these concepts. To achieve this goal the present study applied a questionnaire and collected information directly from research subjects through a field diary. The theoretical elucidated the perception of the achieved results indicating possible actions to be taken. The questionnaire data were analyzed according to qualitative approach guided by Discursive Textual Analysis. The results indicate the need for deepening the teaching of Physics in this area of training, considering it as essential content in professional training (BRAZIL 2000, 2011), little developed knowledge, restricted language and differences between concepts are observed in large part of the results. It was also noticeable that individuals consider important to know the contents of Physics related to their profession. This study identified the level of understanding of the modern Physics concepts, as well as radiology professionals‟ difficulties and curiosities. Understanding students' difficulties can be an important way to recognize the need for new teaching strategies. The results may contribute to the improvement of courses curriculum and to the awareness of pedagogical directions related to the importance of training teachers engaged in the subject of Physics in this education area. / Este trabalho teve o prop?sito de identificar as concep??es de profissionais com forma??o t?cnica em radiologia, atuantes no mercado de trabalho, quanto ao dom?nio dos conceitos de F?sica Moderna relacionados ? sua profiss?o, assim como a valoriza??o que d?o a esses conceitos. Para atingir este objetivo o presente estudo aplicou um question?rio e coletou informa??es diretamente dos sujeitos de pesquisa por meio de um di?rio de campo. A fundamenta??o te?rica elucidou a percep??o dos resultados atingidos apontando poss?veis a??es a serem assumidas. Os dados do question?rio foram analisados segundo abordagem qualitativa orientada pela An?lise Textual Discursiva. Os resultados apontam a necessidade do aprofundamento no ensino de F?sica para essa ?rea de forma??o, pois considerando conte?dos como indispens?veis na forma??o do profissional (BRASIL 2000; 2011), observa-se em grande parte dos resultados conhecimentos pouco elaborados, linguagem restrita e diverg?ncias entre os conceitos. Tamb?m foi percept?vel que os sujeitos consideram importante o conhecimento dos conte?dos de F?sica relacionados ? sua profiss?o. O presente trabalho permitiu identificar o n?vel de compreens?o dos conceitos de F?sica moderna, bem como dificuldades e curiosidades de profissionais com forma??o t?cnica em radiologia. Entender as dificuldades dos alunos pode ser um caminho importante para o reconhecimento da necessidade de novas estrat?gias de ensino. Os resultados obtidos poder?o contribuir com a melhoria dos curr?culos dos cursos e sensibiliza??o das dire??es pedag?gicas quanto ? import?ncia da forma??o do docente que atua na disciplina de F?sica nessa ?rea de forma??o.
397

Rastreamento mamográfico do câncer em mulheres do sul do Rio Grande do Sul com intervenção de mamógrafo móvel

Renck, Décio Valente 12 September 2013 (has links)
Submitted by Cristiane Chim (cristiane.chim@ucpel.edu.br) on 2016-09-05T17:20:11Z No. of bitstreams: 1 decio.pdf: 1843128 bytes, checksum: 49395b8083d0938f97d15c20afe5daaf (MD5) / Made available in DSpace on 2016-09-05T17:20:11Z (GMT). No. of bitstreams: 1 decio.pdf: 1843128 bytes, checksum: 49395b8083d0938f97d15c20afe5daaf (MD5) Previous issue date: 2013-09-12 / The objective of this study was to evaluate a program of prevention and early diagnosis of breast cancer, performed with a mobile mammography unit that visited several cities in Rio Grande do Sul, the southernmost State in Brazil, where these exams were not available. To better contextualize these findings, we compared the characteristics of those women with those of a group of women who were referred for mammography in the city of Pelotas, where such equipment is widely available. With the mobile unit were examined 8607 women residing in 22 municipalities. We identified 37 cases of breast cancer, which corresponds to 4.7 cases per 1000 examinations. On the other hand, in Pelotas, 1,312 patients were submitted to mammography, and the prevalence of breast cancer was 6.9 cases by 1,000 exams. There were no statistical differences between the two prevalences, even after adjusting for potential confounders. The proposed intervention demonstrates that the availability of tests is needed for prevention and early diagnosis of breast cancer, determining the identification of cases whose diagnoses would have been delayed if this unit was not present. / O objetivo foi avaliar um programa de prevenção e diagnóstico precoce de câncer de mama, realizado com uma unidade móvel de mamografia (mamomóvel) que visitou municípios da região sul do Rio Grande do Sul onde não havia um aparelho de mamografia disponível. Para melhor contextualizar as populações examinadas, as características das mulheres avaliadas pelo mamomóvel foram comparadas com as de mulheres encaminhadas para exame mamográfico na cidade de Pelotas. Com a unidade móvel foram examinadas 8607 mulheres, residentes em 22 municípios da zona sul, e foram identificados 37 casos de câncer de mama (4,7 casos por 1000 exames realizados). Em Pelotas, foram examinadas 1312 pacientes, e a prevalência de câncer de mama foi de 6,9 casos por 1000 exames. A prevalência de casos positivos foi estatisticamente semelhante nos dois grupos, mesmo após o ajuste para possíveis fatores de confusão. A intervenção proposta demonstra que a disponibilização de exames é necessária na prevenção e diagnóstico precoce do câncer de mama, determinando a identificação de casos cujos diagnósticos teriam sido retardados se esta unidade não estivesse presente.
398

Perfil de dose em varreduras de tórax por tomografia computadorizada / Dose profile in computed tomography chest scans

Bruno Beraldo Oliveira 14 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Para a otimização das doses de pacientes em tomografia computadorizada (TC), a legislação brasileira estabeleceu os níveis de referência em radiodiagnóstico (NRD) apenas em termos da Dose Média em Cortes Múltiplos (MSAD) em um paciente adulto típico como um parâmetro de controle de qualidade dos tomógrafos. A verificação da conformidade aos NRD pode ser feita por meio da medida da distribuição de dose resultante da varredura de TC. Uma análise da qualidade das varreduras por TC da região metropolitana de Belo Horizonte faz-se necessária através da realização de testes pertinentes descritos no Guia da Agência Nacional de Vigilância Sanitária (ANVISA). A proposta deste trabalho foi investigar, em varredura de tórax, a variação da dose em TC. Para a medição do perfil de dose e o cálculo da MSAD, foram utilizados dosímetros termoluminescentes do tipo bastão de fluoreto de lítio e filmes radiocrômicos distribuídos em cilindros posicionados nas regiões periférica e central de um objeto simulador de polimetilmetacrilato. Através de procedimentos que são adotados internacionalmente, o Índice de Dose da Tomografia Computadorizada (CTDI) foi avaliado com a câmara de ionização tipo lápis, modelo 10X5-3CT. Os resultados de MSAD obtidos com as três diferentes técnicas dosimétricas foram comparados. Os dados obtidos permitem observar a variação do perfil de dose no interior do objeto simulador, sendo que a região periférica apresenta valores de dose maiores que a região central. A variação longitudinal pode ser observada e a dose máxima foi registrada na região da periferia do objeto simulador, no ponto central do eixo longitudinal. Os valores de MSAD calculados estão abaixo do nível de referência em radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para o abdômen. Os resultados contribuem para disseminar e otimizar o procedimento adequado da dosimetria e dos testes de controle de qualidade em TC, assim como efetuar uma análise crítica dos NRD. / For the optimization of the patient dose in computed tomography (CT), the Brazilian legislation only established the diagnostic reference levels (DRLs) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a parameter of quality control of CT scanners. Conformity to DRLs can be verified by measuring the dose distribution in CT scans in addition to the MSAD determination. An analysis of the quality of CT scans of the metropolitan region of Belo Horizonte is necessary by conducting pertinent tests that are presented in the National Agency of Sanitary Vigilance (ANVISA) Guide. The purpose of this study was to investigate, in chest scans, the variation of dose in CT. The dose profile and the MSAD were determined with lithium fluoride termoluminescent dosimeters (TLD-100 Rod) and radiochromic films distributed in cylinders positioned in peripheral and central regions of a phantom of polymethylmethacrylate. The Computed Tomography Dose Index (CTDI) was evaluated with a pencil ionization chamber model 10X5-3CT according to internationally adopted procedures. The MSAD results obtained with the three dosimetric techniques were compared. The obtained data allowed to observe the variation of the dose profile inside the phantom. The peripheral region showed higher dose values than the central region. The longitudinal variation can be observed and the maximum dose was recorded at the edges of the phantom, at the midpoint of the longitudinal axis. The MSAD results were in according to the DRL of 25 mGy established by Brazilian legislation for the abdomen. The results contribute to disseminate the proper procedure and to optimize the dosimetry and the tests of quality control in CT, as well as make a critical analysis of the DRLs.
399

Avaliação da dose glandular e qualidade de imagem de pacientes submetidas a mamografias com processamento de imagem digital / EVALUATION OF MEAN GLANDULAR DOSE AND IMAGE QUALITY OF PATIENTS UNDERGOING MAMMOGRAPHY WITH DIGITAL IMAGE PROCESSING

Marcio Alves de Oliveira 30 August 2011 (has links)
Nenhuma / O câncer de mama é, nos dias de hoje, uma das maiores causas de morte entre as mulheres em todo o mundo, pois muitas vezes não são diagnosticados precocemente. Só no Brasil foram estimados, em 2010/2011, mais de 49 mil novos casos de câncer de mama. Por este motivo, a mamografia cresceu significativamente nos últimos anos. Porém, a mamografia é uma técnica de diagnóstico por imagem que necessita de um cuidado especial, pois radiografias sem qualidade adequada podem ocasionar um falso diagnóstico e, além disso, acarretar a necessidade de repetição do exame, aumentado a dose de radiação na paciente e o risco à indução de novos cânceres. Portanto, é necessário avaliar as doses em mamografia, pois estas devem ser mantidas tão baixas quanto possível, sem reduzir a elevada qualidade de imagem necessária para a detecção precoce do câncer de mama. Neste sentido, este estudo teve como objetivo, avaliar a dose glandular média e qualidade da imagem de pacientes submetidos a exames de rotina em mamografia com sistema de processamento digital na cidade de Belo Horizonte-MG. Para isso, foram selecionados dois serviços com sistemas de processamento digital distintos (FUJI e KODAK). Nestes foram avaliados qualidade de imagem clínica e dose glandular média a que as pacientes são submetidas. Como resultado, foi obtido para o serviço FUJI uma dose média de 1,82 mGy e 2,07 mGy 3,72% para os posicionamentos craniocaudal (CC) e médio lateral oblíqua (MLO), respectivamente. Enquanto que para o serviço KODAK as médias foram de 2,53 mGy e 2,85 mGy 3,72% para os posicionamentos CC e MLO, respectivamente. Portanto, conclui-se que os valores obtidos nesta pesquisa se apresentaram de 50 a 85% acima dos níveis de referência determinados por protocolos internacionais calculados com 50 mm de polimetilmetacrilato (PMMA), que podem estar superestimando a dose para baixas espessuras de mama e subestimando para altas espessuras. / Breast cancer is nowadays one of the biggest killers of women worldwide as they often are not diagnosed early. In Brazil was estimated in 2010/2011, more than 49 000 new cases of breast cancer. For this reason, the mammogram has increased significantly. However, mammography is a technique that requires special care, because poor quality images can cause a false diagnosis, and cause the need for repeat testing, increasing the radiation dose to the patient and the risk to the induction of new cancers. Therefore, it is necessary to evaluate the doses in mammography, as they should be kept as low as possible without reducing the image quality required for the early detection of breast cancer. Thus, this study aimed to evaluate the average glandular dose and image quality of patients undergoing routine screening mammography to digital processing system in the city of Belo Horizonte-MG. To this end, we selected two services with different digital processing systems (Fuji and Kodak). In these image quality were evaluated clinically and average glandular dose that patients are subjected. As a result, the FUJI service was obtained an average dose of 1.82 mGy and 2.07 mGy for the positions craniocaudal (CC) and oblique (MLO), respectively. While Kodak service, the averages were 2.53 mGy and 2.85 mGy for the CC and MLO positions, respectively. Therefore, we conclude that the values obtained in this research were presented from 50 to 85% above the limits set by international protocols calculated with polymethylmethacrylate (PMMA), which may be overestimating the dose to lower breast thickness and underestimated for high thicknesses.
400

Desenvolvimento de metodologia para cálculo da espessura da mama comprimida em mamografia / Development of methodology for calculations of the thickness of breast in depressed mammography

Luciana de Jesus Souza Pinheiro 14 August 2013 (has links)
A dose na paciente é uma consideração importante em mamografia e sua medida possibilita avaliar o risco para a paciente, associado à realização desse exame. Para o cálculo da Dose Glandular Média (DGM) que é definida como sendo a dose média absorvida no tecido glandular no interior de uma mama comprimida no exame de mamografia, esta é a grandeza que melhor caracteriza o risco carcinogênico induzido pela radiação ionizante.Valores da DGM podem ser obtidos por métodos que se baseiam na medida do kerma incidente (Ki), associado a fatores de conversão tabelados que dependem da camada semiredutoras, da composição glandular da mama e da espessura da mama comprimida.Visando estes aspectos foi desenvolvido um objeto teste com bolinhas de chumbo ou seja radiopacas inseridos no mesmo, que colocado no momento da irradiação acima da bandeja de compressão, juntamente com espessuras conhecidas de simuladores de mama, após a exposição e processamento da imagem possibilitou a medida da distância entre os pontos na imagem radiológica. Foram desenvolvidos retas de calibrações para que através destas retas possamos chegar ao valor real da espessura do simulador, que representa uma mama comprimida. A metodologia desenvolvida mostrou que através das retas de calibrações podemos chegar aos valores de espessuras conhecidas, portanto chegarmos ao valor de espessura da mama comprimida. / The dose in the patient is an important consideration in mammography and its measure enables evaluating the risk to patients, associated with this examination. For calculating the Average Glandular Dose (AGD) which is defined as the average absorbed dose in the glandular tissue within a compressed breast in a mammogram, this is the greatness that best characterizes the carcinogenic risk of radiation-induced ionizante.The DGM can be obtained by methods based on the measurement of the incident kerma (Ki) associated with the tabulated conversion factors that depend on the half-value layer of the composition of the glandular breast and breast thickness compressed. Aiming these aspects has baen developed a test object with radiopaque objects included in this test object placed upon irradiation above the tray compression, along with known thicknesses of simulators breast after exposure and image processing allowed the measurement of the distance between points in the radiological image. Calibration curve was developed that through these lines can reach the actual value of the thickness of the simulator, which represents a compressed breast. The methodology has shown that through the straight calibration can reach values of thicknesses known, so we get the amount of compressed breast thickness.

Page generated in 0.0598 seconds