• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 6
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de fatores associados à reoperação em pacientes reumáticos submetidos a cirurgia conservadora da valva mitral / Evaluation of factors associated with reoperation in rheumatic patients undergoing valve repair prior

Severino, Elaine Soraya Barbosa de Oliveira, 1976- 18 August 2018 (has links)
Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T18:24:11Z (GMT). No. of bitstreams: 1 Severino_ElaineSorayaBarbosadeOliveira_D.pdf: 8406293 bytes, checksum: bc2a25ec83eb02498875fd5f899eb087 (MD5) Previous issue date: 2011 / Resumo: Introdução: A doença cardíaca reumática é a principal causa de doença valvar mitral no Brasil. A superioridade da plastia mitral na regurgitação mitral de etiologia degenerativa já tem sido demonstrada por vários estudos, mas ainda há poucos avaliando os resultados da plastia mitral na doença reumática. Objetivo: O objetivo foi avaliar fatores preditivos de risco para reoperação e mortalidade tardia em população de pacientes reumáticos submetidos à plastia da valva mitral. Material e Método: Este é um estudo retrospectivo. Variáveis clínicas, ecocardiográficas e técnicas cirúrgicas foram anotadas. Foram avaliados apenas pacientes submetidos a reparo da valva mitral exclusivamente, ou em conjunto com plastia da valva tricuspide. Para a análise de reoperação e sobrevida foram utilizadas curvas de Kaplan-Meier. Para a análise univariada das variáveis contínuas foi utilizado o teste t de Student ou Mann-Whitney dependendo do tipo de distribuição da amostra. Para as variáveis discretas foi utilizado o teste do Qui-quadrado. Resultados: Um total de 116 pacientes foram incluídos. O tempo de seguimento médio foi de 58,02 ± 45,33 meses. A idade média dos pacientes foi de 31,19 ± 12,72 anos. No pré-operatório 54,8% dos pacientes estavam em classe funcional I, 24,7% em classe II, 17,2% III e 3,2% em classe funcional IV. Não houve reoperação por sangramento na primeira cirurgia. A taxa de reoperação tardia foi de 12,9% (15 pacientes). A mortalidade cardíaca foi de 5,2% e a geral de 7,8% durante o seguimento tardio. A hipertensão pulmonar no pós-operatório esteve associada ao óbito (P<0,01). Na análise univariada os fatores preditivos de reoperação no pré-operatório foram: medida do átrio esquerdo (P=0,03) e o diâmetro diastólico do ventrículo esquerdo (P=0,01). Durante o seguimento os fatores preditivos de reoperação foram: medida do átrio esquerdo (P<0,01), diâmetro diastólico do ventrículo esquerdo (P<0,01) e a pressão sistólica da artéria pulmonar (P=0,02). Na análise de Kaplan-Meier a variável pré-operatório preditiva de reoperação foi o diâmetro diastólico do ventrículo esquerdo (P=0,01). No seguimento as variáveis preditivas de reoperação foram: a presença de hipertensão pulmonar (P=0,02), presença de insuficiência cardíaca (P<0,01) e a insuficiência mitral (P<0,01). Quanto às técnicas de plastia utilizadas a anuloplastia mitral exclusiva e a anuloplastia tricuspide mostraram maior ocorrência de reoperação (P<0,01 para ambas). A ocorrência de reoperação não esteve associada a menor probabilidade de sobrevida. Conclusão: Os pacientes submetidos a reparo da valva mitral tem fatores preditivos de reoperação no pré e no pós-operatório. Estes pacientes devem ser seguidos de forma mais cautelosa. O reparo da valva mitral e seguro em pacientes reumáticos e com boa sobrevida a longo prazo / Abstract: Introduction: Rheumatic heart valve disease is the most frequent cause of mitral valve disease in Brazil. The advantage of mitral valve repair over mitral valve replacement in degenerative mitral regurgitation has already been demonstrated by several studies, but there are few studies evaluating the early and late outcomes of in rheumatic mitral valve repair . Objective: Our aim was to assess predictive risk factors for mitral reoperation and late mortality in a population of rheumatic patients who underwent mitral valve repair. Methods: This is a retrospective study. Clinical, echocardiographic and surgical techniques were noted. For the analysis of reoperation and survival rates were used Kaplan-Meier curve. For the univariate analysis of continuous variables the Student t test or Mann-Whitney test were used where appropriated. For discrete variables the chisquare test was used. Results: One hundred and sixteen patients were included. The average follow-up was 58.02 ± 45.33 months. The mean age was 31.19 ± 12.72 years. At the preoperative time 54.8% of patients were in functional class I, 24.7% in class II, 17.2% class III, and 3.2% in class IV. There were no reoperations due to bleeding in the early postoperative time. The reoperation rate was 12.9% (15 patients) due to mitral valve degeneration after initial repair within the late follow-up. Cardiac mortality was 5.2% and all causes of death was 7.8% during the same period. The presence of pulmonary hypertension at the late follow-up was associated with death (P<0,01). In the univariate analysis, the risk factors for reoperation in the preoperative time were: left atrium dimension (P = 0.03) and left ventricular end diastolic diameter (P = 0.01). During the late follow-up period, predictive factors for reoperation were: left atrium dimension (P <0.01), left ventricular diastolic diameter (P <0.01) and pulmonary artery systolic pressure (P = 0.02). Kaplan-Meier curve analysis showed the left ventricular diastolic diameter (P = 0.01) associated with reoperation. During the late follow-up, the predictors for reoperation were: the presence of pulmonary hypertension (P = 0.02), congestive heart failure (P <0.01) and mitral regurgitation (P <0.01). Analyzing the techniques used in the initial mitral valve repair annuloplasty exclusively and tricuspid annuloplasty showed a higher incidence of reoperation (P <0.01 in both situations). The reoperation event did not decrease the probability of survival within the follow up period. Conclusion: There are predictors of reoperation in the pre- and postoperative time in patients who underwent rheumatic mitral valve repair. These patients should be followed more cautiously. The rheumatic mitral valve repair is safe and shows good long-term survival / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
2

Uso de membrana de poli (alcool vinilico) - PVAI como substituto pericardico : trabalho experimental / Use of polyvinyl alcohol membrane (PVAI) as pericardic susbstitute : experimental work

Oliveira, Pedro Paulo Martins de, 1968- 09 April 2008 (has links)
Orientador: Orlando Petrucci Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T21:17:28Z (GMT). No. of bitstreams: 1 Oliveira_PedroPauloMartinsde_D.pdf: 3207291 bytes, checksum: 643cd7870725684beed7998d60351274 (MD5) Previous issue date: 2008 / Resumo: Introdução: Reoperações representam cerca de 20% das cirurgias cardíacas, quase na totalidade com esternotomia, onde há a formação de aderências entre o coração, esterno e estruturas adjacentes. Lesões das câmaras cardíacas e grandes vasos pela serra esternal ou na dissecção dessas estruturas resultam em aumento da morbimortalidade e do sangramento perioperatório. Vários autores propuseram o uso de substitutos pericárdicos biológicos e sintéticos na tentativa de diminuir o risco de acidentes nas reoperações, porém sem resultados consistentes em longo prazo. A membrana de poli (álcool vinílico) - PVAl reticulado formam um hidrogel bastante estudado como biomaterial, com boa biocompatibilidade e características favoráveis ao seu emprego como substituto pericárdico. Objetivo: Caracterizar a membrana de PVAl quanto à capacidade de absorção de água, calcificação e citotoxidade e estudar o comportamento biológico da mesma como substituto pericárdico. Metodologia: Foram utilizadas amostras da membrana de PVAl reticulada por irradiação e realizados ensaios de citotoxicidade em culturas de células VERO, da capacidade de absorção de água e de calcificação após o implante in vivo. Ratos da Raça Wistar foram divididos em quatro grupos: Grupo controle - pericardiotomia. Grupo Talco - colocação de talco sobre o epicárdio. Grupo PVAl - colocada membrana de PVAl circundando o coração. Grupo PVAl + Talco - colocado talco sobre o epicárdio e a membrana de PVAl circundando o coração. Após oito semanas foi realizada análise macroscópica e histológica dos corações. Avaliação estatística foi realizada com análise de variância (ANOVA) e teste de Dunnett com significância p<0,05. Resultados: A membrana de PVAl não apresentou citotoxicidade, sua capacidade de absorção de água foi de 42,4 ± 0,89% e mostrou valor médio de 0,00422± 0,00256% de cálcio da massa total do material analisado. Na análise macroscópica observou-se maior aderência no grupo Talco. Na análise histológica o grupo PVAl + Talco apresentou maior espessura epicárdica. Os grupos T e PVAl + Talco apresentaram maior número de células inflamatórias. Conclusão: A membrana não é citotóxica, apresentou boa capacidade de hidratação, a absorção de cálcio foi desprezível, não induziu formação de aderências pericárdicas, não provocou aumento da espessura epicárdica e não induziu aumento de migração de células de resposta inflamatória para o epicárdio, mostrando-se interessante para a aplicação desejada. / Abstract: Background: Cardiac surgery reoperations represent around 20% of all surgical procedures. The main incision is sternotomy and after the first operation there are adherences joining the heart, sternum and neighboring structures. Cardiac chambers and great vessels lesions caused by sternal saw increase morbidity and mortality as well as perioperatory bleeding. Several authors had tried pericardial replacement with biological or synthetic materials in order to decrease risks at reoperations, however with no significant results on long term. Polyvinyl alcohol (PVAl) is a well-known hydrogel, with good biocompatibility and favorable properties as a pericardium replacement. Objective: Describe the biological PVAl behavior as a pericardial replacement. Methodology: PVAl samples were reticulated by radiation. Cytotoxicity direct and indirect tests with VERO cells were performed. We tested absorption water capability and in vivo calcification. Wistar rats were divided in four groups: Control - pericardium abrasion; Talc - talc insertion surrounding the heart; PVAl membrane - PVAl surrounding the heart; PVAl + talc - talc and PVAl membrane insertion surrounding the heart. All animals were kept for 8 weeks and euthanized for study. Macroscopic and microscopic analyses were performed. Statistical analyses were performed with ANOVA and Dunnett post test. Results: The PVAl membrane showed no cytotoxicity. The water absorption capability was 42,4 ± 0,89%. The calcification test showed only 0.00422± 0.00256% of calcium in the total mass of analyzed material. Macroscopic analysis showed higher adherences in the talc group. Histological analysis showed higher epicardium thickness in the PVAl + talc group, higher inflammatory cells in the talcum and PVAl + talc groups. Conclusion: The PVAl membrane hasn't cytotoxicity. It has good water absorption capability and calcification was insubstantial. The membrane showed neither adherences formation nor inflammatory response ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Doutorado / Pesquisa Experimental / Doutor em Cirurgia
3

Resultados tardios do uso de próteses no tratamento cirúrgico das grandes hérnias de hiato / Late results of mesh used in the surgical treatment of large hiatal hernias

Brandalise, André, 1970- 27 August 2018 (has links)
Orientador: Nelson Adami Andreollo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-27T00:10:08Z (GMT). No. of bitstreams: 1 Brandalise_Andre_D.pdf: 14069828 bytes, checksum: d178e5d4a6b617f687e38a9c3855f1b7 (MD5) Previous issue date: 2015 / Resumo: Introdução: o tratamento cirúrgico da doença do refluxo gastroesofágico através da fundoplicatura realizada por videolaparoscopia apresenta bons resultados a longo prazo e é amplamente aceita como alternativa à manutenção do tratamento medicamentoso. Entretanto, a abordagem cirúrgica aos pacientes portadores de grandes hérnias de hiato ainda é motivo de discordância entre os especialistas. O uso de prótese para reforçar a hiatoplastia é proposta por alguns e descartada por outros, especialmente por temor de complicações relacionadas à prótese. Objetivo: realizar uma análise dos resultados a longo prazo do uso de próteses para reforço da hiatoplastia em pacientes com grandes hérnias de hiato tratadas por videolaparoscopia. Método: realizamos análise retrospectivo com 78 pacientes operados entre janeiro de 2000 e fevereiro de 2011 que eram portadores de grandes hérnias e que foram tratados através de cirurgia videolaparoscópica com emprego de próteses para reforço da hiatoplastia. Foram incluídos no estudo pacientes com tamanho do hiato superior a 5 cm de diâmetro, em hérnias primárias ou recidivadas. As próteses estudadas foram: polipropileno ¿ em modelo de implantação original, desenvolvido em nosso serviço ¿ e biológica absorvível. O acompanhamento foi realizado através de entrevista clínica e exames complementares ¿ endoscopia digestiva alta e/ou radiografias contrastadas de esôfago, estômago e duodeno. Resultados: observou-se maior presença de pacientes do sexo feminino (69%). A idade variou de 33 a 83 anos. A média de idade nos pacientes com hérnias primárias foi 64,7 anos, enquanto que nas hérnias recidivadas, foi de 52,3 anos. Essa diferença foi estatisticamente significante (p=0,0001). O tempo de seguimento médio foi de 45,8 meses para hérnias primárias e 61,4 meses para as recidivadas. (p=0,09). Na entrevista, 64 pacientes (82,0%) permaneciam assintomáticos, 7 (9,0%) queixavam-se de refluxo, 3 (3,9%) apresentavam disfagia e 4 (5,2%) relataram problemas com gases. Foram realizados exames complementares em 68 pacientes (87,2%). Destes 54 (79,4%) apresentavam exames normais, enquanto 14 (20,6%) apresentavam recidiva (da hérnia ou de esofagite). No grupo de hérnia primária ocorreram recidivas em seis pacientes (13%) e no grupo de hérnias recidivadas, oito (36,4%) apresentaram nova recorrência e essa diferença foi estatisticamente significante (p=0,05). Segundo o tipo de prótese, nos pacientes em que foi empregada a prótese de polipropileno, 13,5% apresentavam recidiva anatômica enquanto que na prótese biológica este valor foi de 31,2%, mas essa diferença observada não atingiu nível de significância estatística (p=0,13). Não foram observadas complicações relacionadas à prótese. Conclusão: O uso de prótese de polipropileno, segundo o modelo apresentado, é seguro a longo prazo e tem baixos índices de recidiva a longo prazo. A prótese biológica apresentou maiores índices de recidiva. Nas hérnias de hiato recidivas, os índices de recidiva são maiores que nas hérnias primárias / Abstract: Introduction: the surgical treatment of gastroesophageal reflux disease by laparoscopic fundoplication has good long-term results and is widely accepted as an alternative to the maintenance of medical treatment. However, surgical approach to patients with large hiatal hernias still causes disagreement among the experts. The use of prosthesis to enhance hiatus is proposed by some and dismissed by others, especially for fear of complications related to the prosthesis. Objective: To perform an analysis of long-term results of the use of prostheses for strengthening hiatoplasty in patients with large hernias treated by laparoscopy. Method: We performed a retrospective analysis of 78 patients operated between January 2000 and February 2011 with large hernias treated by laparoscopic surgery with the use of prostheses for strengthening hiatoplasty. The study included patients with hiatos larger than 5 cm in diameter, in primary or recurrent hernias. The prostheses were: polypropylene - in original model of implementation, developed in our service - and absorbable biological. The monitoring was performed by clinical interview and objective tests - endoscopy and / or barium contrast x-rays of esophagus, stomach and duodenum. Results: there was a higher presence of female patients (69%). The age ranged 33-83 years. The mean age of the patients was 64.7 years in primary hernias, whereas in the recurrent hernias, was 52.3 years. This difference was statistically significant (p = 0.0001). The mean follow-up was 45.8 months for primary hernias and 61.4 months for recurrent. (p = 0.09). In the interview, 64 patients (82.0%) remained asymptomatic, 7 (9.0%) complained of reflux, 3 (3.9%) had dysphagia and 4 (5.2%) reported problems with gas. Objective tests were performed in 68 patients (87.2%). Of these 54 (79.4%) had normal results, while 14 (20.6%) had recurrence (hernia or esophagitis). In the primary hernia group relapses occurred in six patients (13%) and in the recurrent hernia group, eight (36.4%) had recurred and this difference was statistically significant (p = 0.05). According to the type of prosthesis, in patients in whom we used the polypropylene prosthesis, 13.5% had anatomic recurrence while on the biological prosthesis this value was 31.2%, but this difference did not reach statistical significance level (p = 0.13). There were no complications related to the prosthesis. Conclusion: The use of polypropylene mesh, according to the presented model, is safe in the long term and have low recurrence rates. The biological prostheses showed higher recurrence rates. In patientes with recurrent hernias, the recurrence rates are higher than in primary hernias / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
4

Tratamento cirúrgico versus não cirúrgico das luxações acromioclaviculares agudas nos adultos / Surgical versus conservative inverventions for treating acromioclavicular dislocation of the shoulder in adults

Tamaoki, Marcel Jun Sugawara [UNIFESP] January 2011 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:44:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Introdução: As luxações acromioclaviculares são afecções do ombro comuns na traumatologia ortopédica. Ainda hoje existe controvérsia sobre o método de tratamento mais efetivo. Objetivo: Avaliar a efetividade das intervenções cirúrgicas comparadas às não cirúrgicas para o tratamento das luxações acromioclaviculares agudas em adultos. Métodos: Foi realizada busca no Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (até fevereiro de 2009), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2009, Issue 1), MEDLINE (1966 até fevereiro de 2009), EMBASE (1988 até fevereiro de 2009), e LILACS (1982 até fevereiro de 2009). Além disso, foi pesquisada em registros e ensaios clínicos e realizada busca manual de artigos. Não houve restrição quanto à língua ou status de publicação. Foram incluídos estudos randomizados e quase-randomizados que compararam quaisquer técnicas cirúrgicas às não cirúrgicas para o tratamento das luxações acromioclaviculares agudas. Resultados: Três estudos foram incluídos com total de 174 participantes. Dois estudos eram randomizados e um quaserandomizado. Nenhum utilizou instrumentos validados para aferição dos resultados, embora todos relataram maior número de complicações como quebra e migração de implantes no grupo cirúrgico, que também está relacionada ao maior tempo de retorno às atividades prévias. Conclusão: não há evidência suficiente para determinar quando o tratamento cirúrgico está indicado para as luxações acromioclaviculares agudas em adultos. Ensaios com boa qualidade metodológica, amostra adequada, descrição dos resultados por instrumentos validados, comparando métodos cirúrgicos atuais são necessários para definir esta questão. Contudo o tratamento cirúrgico está relacionado a um maior número de complicações e a um maior tempo de retorno às atividades prévias. / Background: Dislocation of the acromioclavicular joint is one of the most common shoulder problems in general orthopaedic practice. The question of whether surgery should be used remains controversial.Objective To assess the relative effects of surgical versus conservative (non-surgical) interventions for treating acromioclavicular dislocations in adults. Method: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (to February 2009), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2009, Issue 1), MEDLINE (1966 to February 2009), EMBASE (1988 to February 2009), and LILACS (1982 to February 2009), trial registries and reference lists of articles. There were no restrictions based on language or publication status. All randomised and quasi-randomised trials that compared surgical with conservative treatment of acromioclavicular dislocation in adults were included. Main results Three trials were included in this review. These involved a total of 174 mainly male participants. Two trials were randomised and one was quasirandomised. None used validated measures for assessing functional outcome. Authors' conclusions There is insufficient evidence from randomised controlled trials to determine when surgical treatment is indicated for acromioclavicular dislocation in adults in current practice. Sufficiently powered, good quality, well-reported randomised trials of currently-used surgical interventions versus conservative treatment for well-defined injuries are required. All three trials, however, reported complications from the breakage and migration of implants used for primary fixation across the acromioclavicular joint that sometimes required a further operation additional to the routine surgery needed for implant removal. Surgery was also associated with a longer time off from work and other activities. / BV UNIFESP: Teses e dissertações
5

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Costa, Lucas Bevilacqua Alves da 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception
6

Avaliação da percepção auditiva da fala em pacientes submetidos ao reimplante coclear / Evaluation of auditory speech perception in patients submitted to cochlear reimplantation

Lucas Bevilacqua Alves da Costa 18 July 2018 (has links)
Estudo retrospectivo, descritivo e longitudinal realizado na Seção de Implante Coclear, Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo (IC-CPA/HRAC/USP). O objetivo deste estudo foi caracterizar o desempenho da percepção auditiva da fala de indivíduos submetidos à cirurgia de reimplante coclear. No total de 1.323 indivíduos submetidos à cirurgia de implante coclear no período de 1990 a janeiro de 2016, consta o registro de 84 indivíduos submetidos à cirurgia de reimplante coclear, correspondendo a 6,3% do total. Deste total de 84, 68 indivíduos atenderam aos critérios de inclusão/exclusão da pesquisa e foram avaliados utilizando-se testes de percepção auditiva da fala, em três momentos: antes da segunda intervenção cirúrgica, após o reimplante e última avaliação de acompanhamento. As variáveis estudadas foram: a) motivo do reimplante coclear; b) etiologia da perda auditiva; c) idade na primeira cirurgia; d) tempo de uso do implante coclear antes do reimplante; e) tempo de recuperação do escore anterior à intervenção; f) tempo de uso atual; g) escore nos procedimentos de avaliação da percepção auditiva da fala, pré e pós-reimplante coclear. Na análise dos dados foi possível observar que a causa mais comum do reimplante foi a falha do dispositivo interno, seguido de razões médicas. Na avaliação auditiva da fala, um total de 61 (89,7%) recuperaram o desempenho observado antes do reimplante coclear e sete (10,3%), não alcançaram o mesmo desempenho. Constatou-se que as variáveis idade do primeiro Implante e tempo de uso do primeiro Implante Coclear, assim como tempo de reimplante, influenciaram nos resultados encontrados. A cirurgia de reimplante coclear é um procedimento viável, contudo a família e o paciente devem ser orientados quanto aos possíveis comprometimentos na percepção auditiva da fala / A retrospective, descriptive and longitudinal study performed in the Cochlear Implant Section, Audiological Research Center of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (IC-CPA / HRAC / USP). This study aimed at characterizing the auditory speech perception of individuals undergoing cochlear reimplantation surgery. Out of 1,323 individuals undergoing cochlear implant surgery from 1990 to January 2016, 84 (6.3%) subjects underwent cochlear reimplantation surgery. From this total of 84, 68 individuals met the inclusion / exclusion criteria of the study and were evaluated using auditory speech perception tests in three moments: before the second surgical intervention, after reimplantation and the last follow-up evaluation. The variables studied were: a) reason for cochlear reimplantation; b) etiology of hearing loss; c) age at first surgery; d) time cochlear implant use before reimplantation; e) recovery time from the previous intervention score; f) time of current use; g) score in the procedures of assessment of auditory speech perception before and after cochlear reimplantation. The data analysis showed that the most common cause of reimplantation was the failure of the internal device, followed by medical reasons. In the auditory speech evaluation, a total of 61 (89.7%) recovered performance before cochlear reimplantation, and seven (10.3%), did not reach the same performance. It was verified that the variables age at the first Implant and time using the first Cochlear Implant, as well as time of reimplantation, influenced the results. Cochlear replantation surgery is a viable procedure, however, the family and the patient should be advised on the possible compromising risks to the auditory speech perception

Page generated in 0.0705 seconds