• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 5
  • 4
  • 1
  • Tagged with
  • 396
  • 259
  • 141
  • 89
  • 71
  • 64
  • 54
  • 47
  • 41
  • 40
  • 37
  • 30
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

O papel do fator de transcrição mitocondrial A (TFAM) na proteção do DNA mitocondrial contra lesões oxidadas / The Role of mitochondrial transcription factor a (TFAM)in the mitochondrial DNA protection against oxidative damage

Tonolli, Paulo Newton 28 January 2014 (has links)
O fator de transcrição mitocondrial A (TFAM) pertence ao grupo das proteínas de alta mobilidade, apresentando um importante papel para a replicação, transcrição e estrutura/organização do DNA mitocondrial (DNAmt). O DNAmt está organizado em um complexo nucleoprotéico, chamado de nucleóide, do qual TFAM é o principal componente protéico, empacotando o DNAmt de forma análoga às histonas no DNA nuclear. Em analogia ao DNA nuclear, foi sugerido que esse empacotamento pode proteger o DNAmt do ataque de espécies oxidantes, enquanto que, por outro lado, poderia também impedir o acesso das enzimas de reparo. Este trabalho visou esclarecer qual o papel de TFAM na proteção do DNAmt e entender como TFAM influencia o reparo do DNAmt. Nossos resultados indicaram que o empacotamento do DNAmt por TFAM pode proteger o DNA da formação de lesões em condições de estresse oxidativo. Células com redução na expressão de TFAM apresentaram taxas alteradas de proliferação e uma menor viabilidade celular após o tratamento com o fotossensibilizador azul de metileno, indicando que TFAM pode contribuir para a manutenção da integridade funcional da mitocondria. A velocidade do reparo do DNAmt, em células Kd-TFAM, foi aparentemente maior, o que indicou a importância da modulação da interação de TFAM com o DNAmt para um reparo rápido e eficiente das lesões oxidadas. Portanto, TFAM desempenha um papel importante para a estabilidade genômica mitocondrial, protegendo o DNAmt dos efeitos deletérios das lesões oxidadas no estresse oxidativo, e também modulando a velocidade do reparo do DNAmt, provavelmente através de modificações/interações que permitam que as enzimas de reparo acessem as lesões no DNAmt. / The mitochondrial transcription factor A (TFAM) belongs to the high mobility group box proteins, and is essencial for replication, transcription and structure/organization of the mitochondrial DNA (mtDNA).The mtDNA is organized in a nucleoproteic complex called the nucleoid, where TFAMis the main protein component,packaging mtDNA in a manner similar to histones in the nuclear DNA. In analogy to the histone role in nuclear DNA, it was suggested that mtDNA packaging by TFAM could protect the mtDNA against oxidized lesions. On the other hand, it could also prevent the access of repair enzymes. This study aimed to understand whether TFAM plays a role in mtDNA stability through these opposing effects of protecting from damage and preventing repair. Our results indicated that TFAM protects the mtDNA against lesion formation upon oxidative stress. Cells with reduced expression of TFAM showed altered proliferation and lower cellular viability after treatment with the photoactivated dye methylene blue, indicating an important role for TFAM in maintaining mitochondrial function and cell survival. MtDNA repair rate was apparently higherin Kd-TFAM cells, which indicated the importance of modulating the interaction of TFAM with mtDNA for a quick and efficient repair of oxidized lesions. Therefore, TFAM plays an important role in maintaining mitochondrial genomic stability by protecting the mtDNA of the deleterious effects of oxidized lesions in oxidative stress, also modulating mtDNA repair, likely through modifications/interactions that modulate its DNA binding activity and access to lesions in mtDNA by DNA repair enzymes.
212

Caracterização de juntas soldadas por Arame Tubular com proteção gasosa do aço ferrítico ASTM A335 P91, antes e após situação de duplo reparo. / Characterization of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW) with shielding gas, before and after double repair situation.

Diego Teixeira Pedro 22 October 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Pouco se sabe a respeito das consequências da operação de reparo nas propriedades mecânicas e metalúrgicas das juntas do aço ASTM A335 grau P91 soldadas por Arame Tubular. Neste trabalho foi realizado um estudo para analisar e caracterizar juntas de um tubo do aço P91 soldadas pelo processo Arame Tubular com proteção gasosa, antes e após situação de duplo reparo. Foram utilizadas técnicas de microscopia eletrônica de varredura (MEV), análise química semiquantitativa por EDS (Energy Dispersive Spectroscopy), microscopia óptica (MO), além da obtenção de medidas de microdureza Vickers e realização de ensaios de impacto e tração à temperatura ambiente. A macrografia revelou a existência de uma nova zona termicamente afetada formada no centro da junta reparada e a análise micrográfica mostrou que esta zona apresentou uma pequena tendência a formação de grãos menores do que na zona de fusão que sofreu reparo, além disso, a região tinha grãos colunares que não são característicos de uma zona termicamente afetada e quantidade de carbonetos menor comparativamente. Não houve variações significativas nos valores de tração e microdureza. Os ensaios de impacto revelaram baixos valores de energia absorvida na zona de fusão do 2 reparo, no entanto, todas as outras zonas avaliadas das juntas com e sem reparo apresentaram valores dentro das especificações. / Little is known about the consequences of the repair operation on the mechanical and metallurgical properties of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW). In this work, a study was made to analyze and characterize joints of P91 steel tube, welded by FCAW with shielding gas, before and after double repair situation. Techniques of scanning electron microscopy (SEM), chemical analysis by semi-quantitative EDS (Energy Dispersive Spectroscopy) and optical microscopy (OM) were used, in addition, Vickers microhardness measurements, impact and tensile tests at room temperature, were carried out. The macrography revealed the existence of a new heat affected zone formed in the center of the repaired joint and the micrographic analysis showed that this zone has a tendency to formation of smaller grains compared to the repaired fusion zone, furthermore, the region has columnar grains which are not characteristics of a heat affected zone and comparatively lesser amounts of carbides. There were no significant variations in the tensile and hardness values. Impact tests showed low values of absorbed energy in the fusion zone of the second repair; however, all other evaluated zones, with and without repair, had values within specifications.
213

Valor progn?stico de polimorfismos nos genes de reparo do DNA XRCC3 E RAD51 em pacientes com carcinoma epiderm?ide oral e de orofaringe

Santos, Edilmar de Moura 24 February 2016 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-08-25T20:42:57Z No. of bitstreams: 1 EdilmarDeMouraSantos_TESE.pdf: 2404882 bytes, checksum: 5eff55db010b690ecc915ee6c24050f0 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-08-26T19:45:12Z (GMT) No. of bitstreams: 1 EdilmarDeMouraSantos_TESE.pdf: 2404882 bytes, checksum: 5eff55db010b690ecc915ee6c24050f0 (MD5) / Made available in DSpace on 2016-08-26T19:45:12Z (GMT). No. of bitstreams: 1 EdilmarDeMouraSantos_TESE.pdf: 2404882 bytes, checksum: 5eff55db010b690ecc915ee6c24050f0 (MD5) Previous issue date: 2016-02-24 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico (CNPq) / Falhas nos genes respons?veis por reparos no DNA podem influenciar no surgimento de c?ncer ou afetar a resposta aos tratamentos. Estudos t?m demonstrado que a varia??o na capacidade de reparo do DNA pode ser resultado de polimorfismos funcionais nestes genes, e alguns destes experimentos sugerem que a presen?a de polimorfismos de nucleot?deos simples (SNPs), em genes de reparo, est? relacionada ao desenvolvimento e resposta ao tratamento de v?rios c?nceres, incluindo o Carcinoma Epidermoide Oral (CEO) e o Carcinoma Epidermoide de Orofaringe (CEOR). Nesta pesquisa avaliou-se a frequ?ncia de tr?s SNPs em dois genes de reparo do DNA RAD51 172G>T (c.-61 G>T, rs1801321), RAD51 135G>C (c.-98 G>C, rs1801320) e XRCC3 T241M (c. 722 C>T, rs861539) em indiv?duos saud?veis (n=130) e indiv?duos com CEO e CEOR (n=126) e investigou-se poss?veis rela??es de tais achados com os desfechos cl?nicos: resposta tumoral ao tratamento com radioterapia e quimioterapia, recidiva, e sobrevida global. Constatou-se frequ?ncia al?lica e genot?pica em equil?brio. A presen?a dos SNPs analisados n?o revelou ser um fator de risco para o desenvolvimento de CEO ou CEOR; contudo, quando associado ao h?bito de fumar ou beber, aumentou o risco de desenvolver o c?ncer de tr?s a cento e cinquenta vezes (p<000,1). A resposta tumoral ao tratamento de radioterapia e quimioterapia foi semelhante nos pacientes com ou sem SNPs. Nenhum polimorfismo demonstrou signific?ncia estat?stica em rela??o ? sobrevida livre de recidiva ou sobrevida global. Os gen?tipos AA e AC do SNP rs861539 no gene XRCC3, os gen?tipos CC e CG do SNP rs1801320 e GG e GT do SNP 1801321 no gene RAD51, aumentam o risco do desenvolvimento de carcinoma epidermoide oral e de orofaringe, quando associados ao h?bito de beber ou fumar. Os polimorfismos estudados nos genes XRCC3 e RAD51 n?o est?o associados ? resposta ? radioterapia, sobrevida livre de recidiva ou sobrevida global. / Faults in the genes responsible for repairs to the DNA can influence the onset of cancer or affect the response to treatment. This research evaluated the frequency of three single nucleotide polymorphisms (SNPs) in two repair genes DNA RAD51 172g> T (rs1801321), RAD51 135G> C (rs1801320) and XRCC3 T241M (rs861539) in individuals without cancer (n = 130) and patients with oral squamous cell carcinoma (OSC) and carcinoma oropharyngeal squamous (ORSC) (n = 126) and investigated possible relationships of these findings with clinical and pathological data and clinical outcomes: tumor response to radiotherapy and chemotherapy, disease-free survival, and overall survival. It was found that the allele and genotype frequencies were in equilibrium Hard-Weinberg equilibrium. The presence of at least one polymorphic allele in XRCC3 (rs861539) gene is associated with histological grade (WHO) higher (p = 0.007). We observed a higher recurrence rate trend (p = 0.08) and more advanced stage (p = 0.08) in the group that had at least one polymorphic allele of RAD51 gene (rs1801321). The presence of the analyzed SNPs not proved to be a risk factor for the development of CEO or CEOR; however, when combined with smoking or drinking, increased the risk of developing cancer from three to one hundred and fifty times. The tumor response to radiotherapy and chemotherapy was similar in patients with and without SNPs. No polymorphism showed statistical significance in relation to recurrence-free survival or overall survival. We conclude that the presence of at least one polymorphic allele of the SNPs rs861539 in XRCC3 gene, rs1801320 and rs1801321 in the RAD51 gene increase the risk of development of OSC and ORSC, when associated with the habit of drinking or smoking. Polymorphisms studied in XRCC3 and RAD51 genes are not associated with response to radiation therapy, relapse-free survival or overall survival.
214

[en] ANALYSIS OF PIPELINE WITH EXTERNAL METAL LOSS REPAIRED WITH STEEL-ADESIVE-REPAIR SYSTEM / [pt] ANÁLISE DE DUTOS COM PERDA DE ESPESSURA REPARADOS COM MULTICAMADAS METÁLICAS COLADAS

MARCO ANTONIO PEREZ ROSAS 11 December 2006 (has links)
[pt] Devido à crescente necessidade de aumentar a disponibilidade de uso imediato de dutos que sofreram danos por perda de espessura ou impacto de objetos estranhos, o uso de reparos tem tido cada vez mais importância. Neste trabalho, um novo método para o reparo de dutos com perda de espessura externa foi analisado. O reparo consiste na utilização de camadas metálicas coladas ao duto com adesivo epóxi. Existem vários tipos de reparos, mas o proposto tem a vantagem de ser facilmente aplicável, prescinde de soldagem, e apresenta módulo elasticidade alto, o que permite uma redução na deformação total presente na região do defeito. Este novo método de reparo tem como objetivo devolver a integridade estrutural do duto de uma forma simples e econômica. Para conhecer o comportamento e avaliar este tipo de reparo, utilizaram-se métodos analíticos, experimentais e numéricos. Fez-se uso da técnica de elementos finitos pela grande vantagem de poder considerar a não linearidade do material, já que foram levadas em consideração situações de estado limite para o cálculo das pressões que originam a plastificação e a ruptura do duto. Foi desenvolvido um modelo analítico para o dimensionamento do reparo, que permite analisar o comportamento das tensões na região do defeito para cada pressão aplicada, procedimento útil em uma seleção ótima do reparo. Na abordagem experimental foram testados oito espécimes tubulares: dois sem defeitos e seis com defeitos usinados para simular a perda de espessura, dos quais cinco foram reparados com diferentes números e tipos de camadas. Os espécimes foram devidamente instrumentados para a obtenção de dados de pressões, variações volumétricas e deformações ocorridas em pontos localizados nos espécimes tubulares. O duto reparado com quatro camadas de aço de baixo carbono e o duto reparado com duas camadas de aço inox 304 suportaram a pressão de ruptura de um duto sem defeito, ambos rompendo em seções afastadas daquelas reparadas. Os dutos reparados com uma, duas e três camadas de aço de baixo carbono romperam na região do defeito. Os resultados experimentais obtidos comprovaram a eficiência da nova técnica de reparo proposta, e foram satisfatoriamente previstos pelos modelos numéricos e analíticos. / [en] Due to increasing need to prolong the availability of immediate use of the pipeline that had suffered to damages of metal loss or strange object impact, the use of repairs has each time more importance. In this work, a new repair system to be utilized on pipeline with external metal loss, was analyzed. The repair system is composed of pre-curved thin layers of steel lamina, which are set in place on the external metal loss defect area of a pipe and cement in place with epoxy resin. There are many types of repair system, but the use of this type of system avoids the need for field welding, and presents high elasticity module, it allows a reduction in the present total deformation in the region of the defect. This new repair system has as objective to return the structural integrity of the pipeline of a simple and economic way. To know the behavior and to evaluate this type of repair, analytical, experimental and numerical methods were used. The use of the finite elements method has the great advantage of being able to consider non linearity of the material for the calculate of the rupture pressure. An analytical model to project the repair was developed, this can analyze the behavior of the stress in the region of the defect for each applied pressure, useful procedure in an excellent election of the repair. In the experimental boarding eight pipe specimens were tested: two without defects and six with defects to simulate the loss of thickness, of which five were repaired with different numbers and types of layers. The specimens were instrumented to obtain data of pressures, volumetric variations and deformations, occurred in the specimens. The pipe repaired with four steel layers of low carbon and the pipe repaired with two stainless steel layers 304 did supported the pressure of rupture of a pipe without defect, both did breach in sections distant those repaired. The pipeline repaired with one, two and three steel layers of low carbon had breached in the region of the defect. The experimental results did prove the efficiency of the new repair system, and satisfactorily had been foreseen by the numerical and analytical models.
215

Células derivadas da medula óssea no reparo de lesões causadas por infecções parasitárias em camundongos quiméricos

Azevedo, Carine Machado January 2013 (has links)
Submitted by Ana Maria Fiscina Sampaio (fiscina@bahia.fiocruz.br) on 2014-05-22T15:50:32Z No. of bitstreams: 1 Carine Machado Azevedo. Células derivadas...2013.pdf: 3773108 bytes, checksum: 06792c88bd29e905b54c5a3d77de8db6 (MD5) / Made available in DSpace on 2014-05-22T15:50:32Z (GMT). No. of bitstreams: 1 Carine Machado Azevedo. Células derivadas...2013.pdf: 3773108 bytes, checksum: 06792c88bd29e905b54c5a3d77de8db6 (MD5) Previous issue date: 2013 / Fundação Oswaldo Cruz. Centro de Pesquisa Gonçalo Moniz. Salvador, BA, Brasil / A contribuição das células de medula óssea na regeneração de tecidos não hematopoiéticos tem sido intensamente investigada desde a descoberta de células-tronco multipotentes neste órgão. Estudos prévios tem demonstrado que células derivadas da medula óssea podem contribuir para a formação de novos hepatócitos e cardiomiócitos. No presente estudo avaliamos a participação endógena das células-tronco de medula óssea no processo de reparo de lesões teciduais na fase crônica da doença de Chagas e esquistossomose experimentalmente induzidas. Para isso, camundongos quiméricos de medula óssea foram gerados após irradiação com dose letal e posterior reconstituição com células de medula óssea provenientes de camundongos transgênicos para a proteína fluorescente verde (GFP). Um mês após a reconstituição, as quimeras foram infectadas pelo T. cruzi ou S. mansoni. Animais quiméricos saudáveis foram mantidos como controles. Camundongos foram eutanasiados em diferentes períodos para análise morfológica, morfométrica e de marcadores específicos através de imunofluorescência do coração e músculo esquelético ou fígado de acordo com o grupo. As infecções por S. mansoni e T. cruzi causaram a mobilização de diferentes populações celulares para o sangue periférico, tais como monócitos, células-tronco hematopoiéticas e mesenquimais e progenitores endoteliais. Nos dois modelos estudados, observamos um aumento no número de células GFP+ após estímulo lesivo nos tecidos analisados. No modelo de doença de Chagas, há um aumento da expressão de MCP-1, 2 e 3 e SDF-1 no coração e músculo esquelético em comparação com animais não infectados, o que pode contribuir para o recrutamento destas células. As células GFP+ contribuem tanto para a formação da lesão, compondo o infiltrado inflamatório, como para a regeneração tecidual através da formação de miofibras, cardiomiócitos, hepatócitos e vasos sanguíneos. As poucas células GFP+ encontradas nos tecidos de camundongos quimeras normais não possuíam morfologia de células parenquimatosas. Concluímos que a medula óssea pode contribuir para a regeneração dos tecidos lesados através de células-tronco ou progenitores que originam células dos músculos cardíaco e esquelético, hepatócitos e vasos sangüíneos. / The contribution of bone marrow cells in non-hematopoietic tissue regeneration has been intensely investigated since the discovery of multipotent stem cells in this organ. Previous studies have shown that bone marrow derived cells may contribute to the formation of new hepatocytes and cardiomyocytes. In the present study, we evaluated the participation of endogenous bone marrow stem cells in the repair of tissue injury in experimentally induced chronic phases of Chagas disease and schistosomiasis. For this purpose, chimeric mice were generated from bone marrow after a lethal irradiation dose and subsequent reconstitution with bone marrow cells from green fluorescent protein (GFP) transgenic mice. A month after reconstitution, chimeras were either infected with Trypanosoma cruzi or Schistosoma mansoni, or kept healthy as controls. Mice were euthanized at different time points for histological, morphometric and specific markers by immunofluorescence analysis in heart and skeletal muscle or in the liver, according to the group. Infections caused by S. mansoni and T. cruzi resulted in the mobilization of different cell populations to the peripheral blood, including monocytes, hematopoietic and mesenchymal stem cells, and endothelial progenitors. In the two models studied, we observed an increase in the number of GFP+ cells after injury stimulus in the tissues analyzed. In the model of Chagas disease, there is an increased expression of MCP-1, 2, 3 and SDF-1 in heart and skeletal muscle compared to uninfected animals, which can contribute to the recruitment of these cells. The GFP+ cells both contribute to lesion formation, comprised of inflammatory infiltrate, as well as tissue regeneration by forming myofibers, cardiomyocytes, hepatocytes and blood vessels. The few GFP+ cells found in control chimera mice tissue lacked parenchymal cell morphology. We concluded that bone marrow may contribute to the regeneration of injured tissues through stem or progenitor cells, which gives rise cardiac and skeletal muscle cells, hepatocytes and blood vessels.
216

Polimorfismos em genes de reparo do DNA (XPC, ERCC1, XRCC7) em mulheres com câncer do colo do útero / DNA repair gene variants XPC, ERCC1, XRCC7 in women with cervical cancer

Saffar, Issamir Farias [UNIFESP] 30 June 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-30. Added 1 bitstream(s) on 2015-08-11T03:26:22Z : No. of bitstreams: 1 Publico-224a.pdf: 1423351 bytes, checksum: 776c88bdbe992943ce07741453832774 (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:22Z : No. of bitstreams: 2 Publico-224a.pdf: 1423351 bytes, checksum: 776c88bdbe992943ce07741453832774 (MD5) Publico-224b.pdf: 1664287 bytes, checksum: dd243856557fd4866c208141ed92a2b1 (MD5). Added 1 bitstream(s) on 2015-08-11T03:26:22Z : No. of bitstreams: 3 Publico-224a.pdf: 1423351 bytes, checksum: 776c88bdbe992943ce07741453832774 (MD5) Publico-224b.pdf: 1664287 bytes, checksum: dd243856557fd4866c208141ed92a2b1 (MD5) Publico-224c.pdf: 1095897 bytes, checksum: 97d738e50d367a15302560070af3514a (MD5) / Estudos demonstram que polimorfismos em genes relacionados ao reparo do DNA estão envolvidos na patogênese de diversas doenças neoplásicas, como o câncer ginecológico, particularmente o câncer do colo do útero. O presente estudo, caso-controle, compara os polimorfismos dos genes XPC, ERCC1 e XRCC7 em 77 mulheres com câncer cervical (70 casos de carcinoma espinocelular e 7 casos de adenocarcinoma do colo do útero) e 73 mulheres saudáveis atendidas no Hospital do Câncer Alfredo Abrão, entre Junho de 2007 e Maio de 2009. No Laboratório de Ginecologia Molecular da EPM-UNIFESP, os polimorfismos desses genes foram detectados pela técnica de reação em cadeia da polimerase seguida da análise do polimorfismo do fragmento de restrição (PCR-RFLP). As distribuições genotípicas dos polimorfismos no grupo de casos e controle estavam em Equilíbrio de Hardy-Weinberg (p>0,05). Pelo teste exato de Fisher as distribuições genotípicas dos polimorfismos (XRCC7 (G-C): GG (11,7%), GC (41,6%) e CC (46,8%) no grupo de casos e GG (20,5%), GC (41,1%) e CC (38,4%) no grupo controle (p=0,31); ERCC1 (C-T): CC (39,0%), CT (51,9%) e TT (9,1%) no grupo de casos e CC (53,4%), CT (38,4%) e TT (8,2%) no grupo controle (p=0,20); XPC (A-C): AA (50,6%), AC (41,6%) e AA (7,8%) no grupo de casos e AA (45,2%), AC (37,0%) e CC (17,8%) no grupo controle, p=0,19) não apresentaram diferença estatística significante. Nossos resultados mostram que os polimorfismos XPC, ERCC1 e XRCC7 não são correlacionados ao risco para desenvolvimento do câncer do colo do útero na população estudada. / TEDE / BV UNIFESP: Teses e dissertações
217

Caracterização de juntas soldadas por Arame Tubular com proteção gasosa do aço ferrítico ASTM A335 P91, antes e após situação de duplo reparo. / Characterization of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW) with shielding gas, before and after double repair situation.

Diego Teixeira Pedro 22 October 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Pouco se sabe a respeito das consequências da operação de reparo nas propriedades mecânicas e metalúrgicas das juntas do aço ASTM A335 grau P91 soldadas por Arame Tubular. Neste trabalho foi realizado um estudo para analisar e caracterizar juntas de um tubo do aço P91 soldadas pelo processo Arame Tubular com proteção gasosa, antes e após situação de duplo reparo. Foram utilizadas técnicas de microscopia eletrônica de varredura (MEV), análise química semiquantitativa por EDS (Energy Dispersive Spectroscopy), microscopia óptica (MO), além da obtenção de medidas de microdureza Vickers e realização de ensaios de impacto e tração à temperatura ambiente. A macrografia revelou a existência de uma nova zona termicamente afetada formada no centro da junta reparada e a análise micrográfica mostrou que esta zona apresentou uma pequena tendência a formação de grãos menores do que na zona de fusão que sofreu reparo, além disso, a região tinha grãos colunares que não são característicos de uma zona termicamente afetada e quantidade de carbonetos menor comparativamente. Não houve variações significativas nos valores de tração e microdureza. Os ensaios de impacto revelaram baixos valores de energia absorvida na zona de fusão do 2 reparo, no entanto, todas as outras zonas avaliadas das juntas com e sem reparo apresentaram valores dentro das especificações. / Little is known about the consequences of the repair operation on the mechanical and metallurgical properties of ASTM A335 grade P91 steel joints welded by Flux-Cored Arc Welding (FCAW). In this work, a study was made to analyze and characterize joints of P91 steel tube, welded by FCAW with shielding gas, before and after double repair situation. Techniques of scanning electron microscopy (SEM), chemical analysis by semi-quantitative EDS (Energy Dispersive Spectroscopy) and optical microscopy (OM) were used, in addition, Vickers microhardness measurements, impact and tensile tests at room temperature, were carried out. The macrography revealed the existence of a new heat affected zone formed in the center of the repaired joint and the micrographic analysis showed that this zone has a tendency to formation of smaller grains compared to the repaired fusion zone, furthermore, the region has columnar grains which are not characteristics of a heat affected zone and comparatively lesser amounts of carbides. There were no significant variations in the tensile and hardness values. Impact tests showed low values of absorbed energy in the fusion zone of the second repair; however, all other evaluated zones, with and without repair, had values within specifications.
218

Efeitos da associação de biomateriais com doadores de óxido nítrico no reparo tecidual cutâneo de camundongos / Effects of biomaterials association with nitric oxide donors in skin tissue repair in mice

Fernanda Seabra Schanuel 24 February 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / A aplicação tópica de doadores de óxido nítrico é conhecida pelos seus efeitos benéficos no reparo tecidual cutâneo. O objetivo deste trabalho foi avaliar os efeitos da associação de biomateriais com doadores de óxido nítrico no reparo tecidual cutâneo de camundongos. Camundongos swiss machos foram submetidos a lesões excisionais por punch de biópsia de 8 mm no dorso. Os animais foram separados em 4 grupos (n=6 em cada grupo) de acordo com a aplicação do curativo de polivinil álcool e hidrogel sobre a lesão de punch: a) grupo polivinil álcool com grupos tiol e Pluronic F-127 (PVA-SH/F127) - tratado com hidrogel sem S- nitrosoglutationa (GSNO) e filme sem óxido nítrico; b) grupo polivinil álcool S-nitrosado (PVA-SNO/F127-GSNO) - tratado com hidrogel contendo GSNO e filme com óxido nítrico; c) grupo PVA-SNO - tratado apenas com filme óxido nítrico e d) grupo PVA-SNO/ F127 - tratado com hidrogel sem GSNO e filme com óxido nítrico. Os animais foram tratados por 7 dias consecutivos com aplicação diária de curativos com seus respectivos biomateriais. Após 7 dias de tratamento, foram retirados os curativos e as lesões foram deixadas cicatrizar por segunda intenção. O grupo tratado com filme de PVA-SNO (d) associado ao hidrogel F127, comparado com os demais grupos descritos acima, apresentou melhora no reparo tecidual, melhora da contração da lesão, diminuição do gap epitelial e densidade celular, aceleração da fase inflamatória, aumento da diferenciação miofibroblástica e aumento da expressão de colágeno do tipo III (p<0,05, ao menos). Com base nesses dados, a combinação de filmes PVA liberadores de óxido nítrico com F-127 pode representar uma nova abordagem para o tratamento de lesões cutâneas. / Topical application of nitric oxide donors is known for its beneficial effects on skin tissue repair. The objective of this study was to evaluate the effects of biomaterials association with nitric oxide donors in skin tissue repair in mice. Males swiss mice underwent excisional lesion 8 mm biopsy punch on the back. The animals were separated in 4 groups (n=6 in each group) in according with dressing application of polyvinyl alcohol and hydrogel on punch lesion: a) poly (vynil alcohol) with thiol groups and Pluronic F-127 hydrogels (PVA-SH/F127) group - treated with hydrogel without S- nitrosoglutathione (GSNO) and film without nitric oxide; b) poly(vinyl alcohol) S-nitrosated (PVA-SNO/F127-GSNO) group - treated with hydrogel with GSNO and film with nitric oxide; c) PVA-SNO group - treated only with film containing nitric oxide and d) PVA-SNO/ F127 group - treated with hydrogel without GSNO and film with nitric oxide. The animals were treated for 7 consecutive days with daily application of dressings to the respective biomaterial. After 7 days of treatment, the dressings were removed and the lesions were allowed to heal by second intention. The group treated with PVA-SNO film associated with the hydrogel F127 (d), compared with the other groups described above, showed improvement in tissue repair, enhancing wound contraction, decreased wound gap and cellular density, acceleration of the inflammatory phase, increased myofibroblast differentiation and increased expression of collagen type III (p<0,05, at least). Based on these data, the combination of PVA films releasing nitric oxide with F-127 may represent a new approach treatment of cutaneous lesions.
219

Desenvolvimento de arcabouços a base de polímeros biocompatíveis PLA e PCL com agentes antibacterianos

Silva, Fernanda Waitman de Oliveira January 2015 (has links)
Orientador: Prof. Dr. Jean Jacques Bonvent / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Biotecnociência, 2015. / Arcaboucos polimericos sao de interesse crescente no campo da engenharia de tecidos. Alguns biopolimeros tais como PLLA -poli (acido latico) e PCL . poli(¿Ã- caprolactona) tem sido amplamente utilizados na composicao destes arcaboucos devido a sua biocompatibilidade, biodegradabilidade e baixa toxicidade. Alem disso, estes biomateriais precisam ter uma boa adesao celular e proliferacao para serem eficazes na reparacao de tecidos. A fim de evitar a invasao de microorganismos, durante o processo de cicatrizacao, e importante a incorporacao de um agente antimicrobiano, para servir como uma barreira protetora e prevenir a infeccao no local da lesao. Tres tipos de arcaboucos foram desenvolvidos a base de PLLA e PCL, e da blenda PCL/PLA - 50/50. A porosidade das membranas de biopolimero foi controlada pela incorporacao de particulas de cloreto de sodio com determinada faixa de tamanho, como agente porogenico, na solucao polimerica, a qual foi, em seguida, removido apos a evaporacao do solvente, por imersao da membrana para a agua para dissolver o sal. A tetraciclina tem sido incorporados a membrana como um agente antibiotico. A morfologia da membrana, estrutura molecular e incorporacao da tetraciclina foram analisados por microscopia eletronica de varredura (MEV), FTIR e microscopia de fluorescencia. A cinetica de libertacao do farmaco foi investigadam atraves da monitorizacao da concentracao de tetraciclina difundida em solucao de PBS (pH 7,4), por meio de espectroscopia de UV-VIS. Os dados experimentais mostraram que a uma porosidade de cerca de 69% foi obtida. A incorporacao de tetraciclina mostrou ser bastante eficaz e uniforme nos arcaboucos, contudo observa-se melhores resultados no caso de PCL puro. A cinetica de libertacao do farmaco e de primeira ordem para arcaboucos com PLA e PCL, puros. No entanto, no caso da blenda, o processo de libertacao do farmaco nao segue nenhum modelo cinetico estabelecido. Tais resultados sugerem que estes suportes de biopolimero podem ser eficazmente produzida com caracteristicas porosas e com a incorporacao de antibioticos, a fim de promover uma libertacao controlada da droga para o processo de reparo tecidual. / Polymeric scaffolds are of growing interest in the field of tissue engineering . Some biopolymers such as PLA - poly lactic acid and PCL - polycaprolactone have been widely used in the composition of these scaffolds due to their biocompatibility, biodegradability and low toxicity. In addition, these biomaterials need to have a good cell adhesion and proliferation to be effective in tissue repair. Furthermore, the formation of pores in the scaffolds is directly related to a better adhesion of material to the cells. In order to avoid microorganism invasion that during the healing process it is important to incorporate an antimicrobial such as tetracycline, to serve as a protective barrier and prevents infection at the site of the injury. Three types of scaffolds were develop, based on PCL, and their blend 50/50, by means of casting process. The porosity of the biopolymer membranes was controlled achieved by the incorporation of sodium chloride particles of given size, as a porogene agent, into the polymer solution, which was then removed after the solvent evaporation by immersion of the membrane into water to dissolve the salt. Tetracycline has been incorporated into to the membrane as an antibiotic agent. The membrane morphology, molecular structure e incorporation of the tetracycline were analyzed by Scanning Electron Microscopy (SEM), FTIR and Fluorescence Microscopy. The drug release kinetic was investigated by monitoring the concentration of tetracycline that diffused to a PBS solution (pH 7.4), by means of uv-vis spectroscopy. The experimental data showed that a medium porosity, of about 69%, could be reached. The incorporation of tetracycline was found to be quite effective and uniform into the scaffolds, tending to lead to better results in the case of pure PCL. The drug release kinetic is of first order for the pure PLA and PCL scaffold. Nevertheless, in the case of the blend, any of the usual kinetic model could describe the drug release process.Such results suggested these biopolymer scaffolds could be effectively produced with porous characteristics and with incorporation of antibiotics in order to promote a controlled drug liberation for wound healing process.
220

Reparo ósseo em scaffolds de TI6AL4V sinterizados pela tecnologia de sinterização direta de metais a laser (DMLS) submetidos a tratamento de superfície associado à aplicação de ultrassom de baixa intensidade (LIPUS) / Bone repair in Ti6Al4V porous scaffolds processed by direct seletive laser melting submited to surface treatment associated low intensity pulsed ultrasound – (LIPUS)

Bastos, Jaqueline Silva [UNESP] 20 January 2016 (has links)
Submitted by Jaqueline Bastos (keca78@yahoo.com.br) on 2016-04-26T17:00:34Z No. of bitstreams: 1 TESE JAQUELINE S BASTOS - finalizando 180316.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-04-28T17:50:25Z (GMT) No. of bitstreams: 1 bastos_js_dr_guara.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) / Made available in DSpace on 2016-04-28T17:50:25Z (GMT). No. of bitstreams: 1 bastos_js_dr_guara.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) Previous issue date: 2016-01-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo in vivo foi verificar a resposta óssea de scaffolds porosos revestidos processados pela técnica de Sinterização Direta de Metais a laser (DMLS) associado à terapia de ultrassom de baixa intensidade. Os scaffolds foram processados empregando a técnica DMLS e tratados termicamente a 1000°C por 24 horas. Três tipos de tratamento de superfície foram avaliados: Alcalino, biomimético e imobilização de alendronato de sódio. Para o tratamento alcalino, as amostras foram imersas na solução de NaOH (5M) a 60ºC por 24 horas. O tratamento biomimético consistiu na imersão dos scaffolds em solução SBF (SimulatedBodyFluid) enquanto a imobilização do alendronato foi realizada a partir da imersão dos scaffolds em uma solução formada por SBF e medicamento durante 5 dias. As superfícies dos scaffolds foram avaliadas para cada etapa empregando microscopia eletrônica de varredura (MEV) e análise por difração de raios-X. Os scaffolds foram implantados na tíbia direita de 85 ratos machos da raça wistar com idade média de 12 semanas. A microtomografia computadorizada (µCT) e análise histológica foram realizadas para avaliar o reparo ósseo no defeito. As micrografias das superfícies obtidas mostraram mudanças no aspecto da superfície e composição química de acordo com o tratamento. O tratamento biomimético promoveu o crescimento da apatita sobre a superfície enquanto a imobilização com alendronato suprimiu sua formação. As imagens obtidas na microtomografia mostraram elevado valor de densidade óssea para o último grupo. No entanto, análises histológicas mostraram a formação de cápsula fibrosa em torno dos scaffolds a qual foi minimizada usando ultrassom pulsado de baixa intensidade. No entanto, mais estudos precisam ser realizados para avaliar a influência da geometria dos scaffolds na incorporação de medicamentos. / The objective of this in vivo study was to verify the bone response of coated Ti6Al4V porous scaffolds processed by Direct Metal Laser Sintering (DMLS) technique associated to low intensity pulsed ultrasound therapy. Scaffolds were processed by using Direct Metal Laser Sintering technique (DMLS) and heat treated at 1000 °C for 24 hours. Three types of surface treatments were evaluated: alkaline, biomimetic and sodium alendronate immobilization. For alkaline treatment, samples were immersed in a NaOH (5M) solution at 60ºC for 24 hours. Biomimetic treatment consisted in the immersion of the scaffolds into Simulated Body Fluid solution while for sodium alendronato immobilization the scaffolds were immersed in the solution formed by SBF plus drug during 5 days. The scaffolds surfaces were evaluated after each step employing SEM (Scanning Electron Microscopy)and X-rays diffraction analysis(XRD). Scaffolds were implanted into right tibia of 85 male Wistar rats with average age of 12 weeks. X-rays micro-computed tomography (µCT) and histological analysis were carried out to evaluate the bone repair on the defect. Micrographs analysis showed that the aspect of the surfaces and chemical composition changed according treatment. Biomimetic treatment promoted the growth of the apatite on the surface; in contrast the immobilization of alendronate suppressed apatite formation. Micro CT images showed higher value of bone density for the last group. However, histological analysis showed the formation of encapsulation fibrous around the scaffolds. This formation was minimized by using low intensity pulsed ultrasound technique, however, more studies can be carried out to evaluate the influence of scaffolds geometry in the drug incorporation.

Page generated in 0.0669 seconds