• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 201
  • 17
  • 7
  • 5
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 244
  • 195
  • 139
  • 115
  • 88
  • 80
  • 74
  • 71
  • 57
  • 57
  • 50
  • 50
  • 49
  • 45
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avalia??o de postes de Eucalyptus retirados da rede el?trica por microscopia eletr?nica de varredura e ensaios de flex?o

Abruzzi, Rafael Colombo 23 March 2012 (has links)
Made available in DSpace on 2015-04-14T13:58:48Z (GMT). No. of bitstreams: 1 438591.pdf: 14141223 bytes, checksum: 39eb1c71b3230f28ddcc9dc1ae6526c5 (MD5) Previous issue date: 2012-03-23 / This paper presents results of tests on poles of wood of different species of Eucalyptus, new and removed from the network of distribution of electric energy in southern Brazil. Are presented correlations between mechanical properties, density, state of deterioration and lumen diameter of Eucalyptus poles. The state of deterioration was determined by field inspections. Poles in various states of deterioration were removed from the network for static bending tests and density measurements. Analysis of the lumen diameter were performed by scanning electron microscopy to correlate the density with the wood anatomy and identification of the treatment used as a preservative. The mechanical tests indicated that the average values of bending strength and stiffness decline with the deteriorating state of Eucalyptus. But, there was a large variation in these measures influenced by the density of the wood. Less dense woods presented low residual mechanical strength even though not presenting signs of deterioration. This study indicated that the state of deterioration measured by field inspection alone is not a good indicator for predicting the durability of eucalyptus structures, making necessary a preliminary analysis of the density. The data obtained from SEM/EDX about chemical treatment and morphological characterization of wood structures come to complement the data obtained through inspection that allowed a real evaluation of the deterioration of these poles on the network. / O presente trabalho apresenta resultados de testes realizados em postes de madeira, de diferentes esp?cies de eucalipto, novos e retirados da rede de distribui??o de energia el?trica no Sul do Brasil. S?o apresentadas correla??es obtidas entre propriedades mec?nicas, densidade, estado de deteriora??o e di?metro do l?men das fibras de postes de eucalipto. O estado de deteriora??o foi determinado por inspe??es em campo. Postes em diferentes estados de deteriora??o foram retirados da rede para ensaios de flex?o est?tica, medidas de densidade. An?lises do di?metro do l?men foram realizadas por Microscopia Eletr?nica de Varredura para correlacionar a densidade com a estrutura anat?mica da madeira e para identifica??o do tratamento empregado como preservante. Os testes mec?nicos indicaram que os valores m?dios da resist?ncia a flex?o e da rigidez decrescem com o estado de deteriora??o do eucalipto. Entretanto, verificou-se uma grande varia??o nessas medidas influenciada pela densidade da madeira. Madeiras menos densas apresentaram baixa resist?ncia mec?nica residual mesmo sem apresentar sinais de deteriora??o. Esse estudo indicou que o estado de deteriora??o avaliado pela inspe??o em campo, por si s? n?o ? um bom indicativo para prever a durabilidade das estruturas de eucalipto, fazendo-se necess?ria uma an?lise preliminar da densidade da mesma. Os dados obtidos com MEV/EDS, sobre o tratamento qu?mico e a caracteriza??o morfol?gica das estruturas de madeira v?m a complementar os dados obtidos com a inspe??o que possibilitaram uma avalia??o real da deteriora??o desses postes na rede.
122

Determina??o do m?dulo de elasticidade din?mico em concreto via t?cnica de excita??o por impulso

Moraes, Carlos Alexandre Pereira de 21 December 2012 (has links)
Made available in DSpace on 2015-04-14T13:58:56Z (GMT). No. of bitstreams: 1 445160.pdf: 12986267 bytes, checksum: 9efe372b5540cb31572394dfe565fd21 (MD5) Previous issue date: 2012-12-21 / The non-destructive dynamic analysis is an important tool for testing the integrity and safety of and structure, once it can identify and locate damage and detect changes in its deformability. The dynamic test also provides the values of frequency and other parameters, whose variations can be used to identify not only the presence of damage but also to determine the equivalent stiffness of material. In addition, the dynamic non-destructive testing has the advantage of providing overall information of the structure and can be repeated and compared over time. The main objective of this study was to determine the elastic modulus of different concrete mixtures with the presence of expanded clay. For this purpose, we used the Impulse Excitation Technique, which is one of dynamic nondestructive techniques, wherein the determination of the dynamic modulus of elasticity is made from natural frequencies of vibration. The dynamic modulus of elasticity was compared with the static modulus of elasticity (initial tangent modulus and secant modulus) calculated from the static tests of simple uniaxial compression. As the compressive strength, the values of initial tangent modulus (Ec0) and the secant modulus (Ecs) determined from the compression tests were dependent on the characteristics of concrete, increasing as the cement content increased. The value of the secant modulus of elasticity was more appropriate as compared with the tangent modulus due to its better correlation with the value of dynamic modulus of elasticity. The results indicate that the nondestructive testing via impulse excitation can be used to determine the dynamic modulus of elasticity of concrete with expanded clay. / A an?lise din?mica n?o-destrutiva ? uma importante ferramenta para a verifica??o da integridade e da seguran?a de uma estrutura, podendo identificar e localizar danos, al?m de detectar mudan?as na sua deformabilidade. O ensaio din?mico fornece os valores de freq??ncia, entre outros par?metros, cujas varia??es podem ser utilizadas para n?o s? para identificar a presen?a do dano, mas tamb?m para determinar a rigidez do material. O principal objetivo deste trabalho foi determinar o m?dulo de elasticidade de diferentes tra?os de concreto com a presen?a de argila expandida. Para tal, utilizou-se a T?cnica de Excita??o por Impulso, que ? uma das t?cnicas de an?lise din?mica n?o destrutiva, na qual a determina??o do m?dulo de elasticidade din?mico ? feita a partir das frequ?ncias naturais de vibra??o. O m?dulo de elasticidade din?mico foi comparado com os m?dulos de elasticidade est?tico (m?dulo tangente inicial e m?dulo secante) calculados a partir dos ensaios est?ticos de compress?o uniaxial simples. Assim como a resist?ncia ? compress?o, os valores do m?dulo tangente inicial (Ec0) e do m?dulo secante (Ecs) encontrados a partir do ensaio de compress?o foram dependentes dos tra?os de cimento, aumentando a medida que o conte?do de cimento aumentou. O valor do m?dulo de elasticidade secante mostrou-se mais apropriado quando comparado com o m?dulo tangente, devido a sua melhor correla??o com o valor do m?dulo de elasticidade din?mico. Os resultados obtidos indicam que o ensaio n?o destrutivo via excita??o por impulso pode ser utilizado para determinar o m?dulo de elasticidade din?mico do concreto com argila expandida.
123

Propriedades tribocorrosivas de multicamadas TI/TIN : depend?ncia do comprimento de modula??o e propor??o da camada cer?mica

Jacobsen, Saulo Davila 08 March 2007 (has links)
Made available in DSpace on 2015-04-14T13:59:14Z (GMT). No. of bitstreams: 1 390390.pdf: 5911788 bytes, checksum: 86d66873f5ffc52b061362edf8178ade (MD5) Previous issue date: 2007-03-08 / A aplica??o de revestimentos de nitreto de tit?nio como camada protetora de a?os em situa??es com caracter?sticas tribocorrosivas tem obtido muito sucesso ao longo dos anos. Entretanto, a resist?ncia contra corros?o aquosa s? ? obtida quando a camada protetora for destitu?da de imperfei??es, pois o ataque corrosivo se propaga em defeitos associados ? poros, contorno de gr?os, e ? uma morfologia colunar encontrada em filmes monol?ticos depositados por sputtering. Estudos recentes mostraram que uma poss?vel solu??o para evitar a propaga??o da estrutura colunar ? a produ??o de revestimentos tipo multicamadas, promovendo assim barreiras para o meio agressivo. Em condi??es espec?ficas, filmes nanoestruturados do tipo multicamadas apresentam valores extremamente elevados de dureza, de acordo com a varia??o do seu per?odo de modula??o. O objetivo deste trabalho ? mostrar o comportamento tribocorrosivo de multicamadas de Ti/TiN, depositados pela t?cnica de magnetron sputtering, atrav?s de diversos comprimentos de modula??o e diferentes propor??es de TiN para cada modula??o. Medidas de Espectrometria de Retroespalhamento de Rutherford (RBS) e de refletividade de raio X (XRR) mostraram que as multicamadas foram obtidas com sucesso em seu processo de deposi??o. As propriedades mec?nicas apresentadas por esses revestimentos mostraram caracter?sticas de super-rede de dureza e as propriedades corrosivas aliadas ?s medidas qualitativas de desgaste mec?nico (H/E) mostraram elevado grau de prote??o, apresentando um grande potencial para aplica??es pr?ticas.
124

Aplica??o de filmes finos de tit?nio em componentes acetabulares de uhmwpe para prote??o contra oxida??o devido a exposi??o ? radia??o X

Vasconcellos, Let?cia Ara?jo 17 July 2006 (has links)
Made available in DSpace on 2015-04-14T13:59:17Z (GMT). No. of bitstreams: 1 383160.pdf: 3194550 bytes, checksum: cc6dcfdfc93d7782e5f949d40152d488 (MD5) Previous issue date: 2006-07-17 / Os implantes de quadril s?o constitu?dos de uma cabe?a esf?rica met?lica que e. g., ? de a?o inoxid?vel 316-L ou ligas de Cr-Co, al?m de um componente polim?rico (UHMWPE). A aplica??o da radia??o gama usada no processo de esteriliza??o e dos raios X de diagn?stico utilizados no controle cl?nico da pr?tese podem contribuir na degrada??o prematura da superf?cie do UHMWPE resultando numa diminui??o do seu tempo de vida ?til. Neste trabalho, foi estudado o grau de prote??o de revestimentos tipo filme fino de tit?nio sobre o componente polim?rico (UHMWPE) em fun??o da exposi??o aos raios X de diagn?stico, comparando-os com os pol?meros n?o revestidos que tamb?m foram expostos ao mesmo tipo de radia??o. Parte destas amostras foram submersas em uma solu??o de HBSS (Hank s Balanced Salt Solution), a qual ? freq?entemente utilizada em culturas de c?lulas, pois simula o meio fisiol?gico do organismo humano. As amostras foram analisadas por diversas t?cnicas de caracteriza??o, dentre elas, a t?cnica de nanodureza para uma an?lise das propriedades mec?nicas do pol?mero, microscopia eletr?nica de varredura (MEV) para observa??o da qualidade superficial do UHMWPE e infravermelho por transformada de Fourier (FTIR) para avalia??o das modifica??es na composi??o qu?mica do pol?mero. Ap?s serem irradiadas, as amostras utilizadas na primeira parte do trabalho, os resultados dos testes de nanodureza levaram a concluir que as propriedades mec?nicas do UHMWPE variam de lote para lote. As an?lises de MEV indicaram dois fatos claros: primeiramente que as amostras revestidas apresentavam uma qualidade superficial com menos danos que as amostras revestidas em concord?ncia com as an?lises de nanodureza e FTIR. Desta forma, com base nos resultados obtidos, podemos concluir que nossa hip?tese inicial, de que uma fina camada de tit?nio pode diminuir a oxida??o superficial do UHMWPE, ? verdadeira.
125

Deposi??o e caracteriza??o de revestimentos de Ni-Ti e Ni-Ti/Nb para aplica??es biom?dicas

Vargas, Andr? Lu?s Marin 30 August 2007 (has links)
Made available in DSpace on 2015-04-14T13:59:19Z (GMT). No. of bitstreams: 1 396764.pdf: 5447809 bytes, checksum: 95a031242ec95fc4971f2c3bd2c511a0 (MD5) Previous issue date: 2007-08-30 / Entre as ligas de mem?ria de forma (SMA shape memory alloys) as de n?quel-tit?nio (Ni-Ti) s?o as mais importantes e pr?ticas devido, principalmente, ?s suas excelentes propriedades mec?nicas, excelentes propriedades que resistem ? corros?o, etc. A import?ncia dessas ligas, al?m do efeito de mem?ria de forma (SME), tamb?m est? relacionada aos efeitos de Superelasticidade ou Pseudoelasticidade (PE), o que permite a esse material alterar suas fases sob condi??es espec?ficas e retornar ? sua forma original. Essas ligas s?o utilizadas em aplica??es biom?dicas (material em volume), e em diversos campos da micro engenharia. Entretanto, filmes finos de NiTi s?o raramente utilizados em aplica??es biom?dicas, em sua maioria devido ? dificuldade em produzir filmes capazes de produzirem os mesmos efeitos encontrados no material em volume. Para tal, ? preciso alterar as concentra??es at?micas dos filmes de maneira precisa, a fim de se obter a fase cristalina necess?ria para a ocorr?ncia de tais efeitos. Outra possibilidade ? a utiliza??o de filmes do tipo multicamada, os quais s?o produzidos em sua maioria pela t?cnica de Magnetron Sputtering, aliado a um tratamento t?rmico espec?fico, o que possibilita a transforma??o de uma estrutura amorfa para uma cristalina. O objetivo deste trabalho ? depositar filmes finos monol?ticos e do tipo multicamada de Ni-Ti/Ti e NiTi/Nb pela t?cnica de DC Magnetron Sputtering para aplica??es biom?dicas e caracterizar propriedades mec?nicas de dureza e m?dulo de elasticidade, composi??o qu?mica e estrutura cristalina, e a resist?ncia ? corros?o dos mesmos antes e ap?s o tratamento t?rmico das ligas depositadas. Medidas de difra??o de raios X (DRX), e de fluoresc?ncia de raios X (FRX), mostraram que a estrutura cristalina e a composi??o foram obtidas com sucesso. As propriedades mec?nicas e de resist?ncia ? corros?o apresentadas por estes revestimentos mostraram caracter?sticas excelentes de biocompatibilidade. Os ensaios de corros?o foram feitos segundo as recomenda??es contidas na norma ASTM F746.
126

Avalia??o da resist?ncia ? fratura de molares endodonticamente tratados com preparo MOD transfixados por um pino de fibra de vidro e restaurados com diferentes materiais

F?vero, Fernando Jos? 20 January 2017 (has links)
Submitted by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-05-05T17:20:11Z No. of bitstreams: 1 TES_FERNANDO_JOSE_FAVERO_PARCIAL.pdf: 219648 bytes, checksum: c82c65601bd3d6d321aa7ab11b1a88c2 (MD5) / Made available in DSpace on 2017-05-05T17:20:11Z (GMT). No. of bitstreams: 1 TES_FERNANDO_JOSE_FAVERO_PARCIAL.pdf: 219648 bytes, checksum: c82c65601bd3d6d321aa7ab11b1a88c2 (MD5) Previous issue date: 2017-01-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objetivos: 1) Avaliar ? resist?ncia ? fratura de molares endodonticamente tratados com preparos cavit?rios MOD e restaurados com Riva light cure (RLC) ou Riva Silver (RS) com e sem a presen?a de pino de fibra de vidro transfixado associado ? resina Bulk Fill Flow; 2) Avaliar o padr?o de fratura ap?s o ensaio mec?nico. Materiais e M?todos: Cinquenta terceiros molares supeiores extra?dos foram divididos em 5 grupos (n=10 por grupo): H?gidos (H); Preparo MOD (MOD) + Tratamento endod?ntico (TE) + cimento de ion?mero de vidro Riva Light Cure (GI); MOD + TE + cimento de ion?mero de vidro Riva Silver (GIS); MOD + TE + resina Bulk Fill Flowable (BFF) + pino de fibra de vidro horizontal (TFP) + RLC (GIP); MOD + TE + BFF + TFP + RS (GISP). Os preparos cavit?rios MOD e os tratamentos endod?nticos foram realizados em todos os grupos, exceto os h?gidos. A face vestibular e palatina dos grupos (GIP) e (GSIP) receberam a transfixa??o horizontal do pino de fibra de vidro seguido da inser??o da resina composta Bulk Fill Flow, Riva light cure ou Riva Silver de acordo com os grupos de estudo. Os dentes foram submetidos ao teste de resist?ncia ? fratura em uma m?quina de ensaio universal. O tipo de fratura ap?s o ensaio foi classificado em: fratura em assoalho pulpar (condenados) ou em c?spide (recuper?vel). Resultados: M?dias em Newtons(N) seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (P<0,05%): H 3955,6NA; GI 1215,6NB; GIS 1195,8NB; GIP 2064,6NC GISP 2386,5NC. O padr?o de fratura foi similar entre os grupos testados com 54% de fraturas recuper?veis e 46% para dentes condenados. Conclus?es: A associa??o do pino de fibra de vidro, resina Bulk Fill flow, Riva light cure (GIP) ou Riva Silver (GISP) recuperou, respectivamente 52,19%, e 60,23% da resist?ncia ? fratura de um dente h?gido, sendo, em m?dia, 2x maior que os resultados dos grupos (GI) e (GIS). / Objetivos: 1) Avaliar a resist?ncia ? fratura de terceiros molares com preparos cavit?rios MOD tratados endodonticamente e restaurados com resina composta de forma direta, cimento de ion?mero de vidro modificado por resina ou cimento de ion?mero de vidro tipo silver com e sem a presen?a de pino de fibra de vidro transfixado horizontalmente em molares endodonticamente tratados; 2) Avaliar o padr?o de fratura dos dentes ap?s o ensaio de resist?ncia ? fratura. Materiais e M?todos: Setenta molares h?gidos extra?dos foram embutidos em resina acr?lica e divididos em 7 grupos (n=10 por grupo): H?gidos (H); preparo cavit?rio (MOD) + Tratamento endod?ntico (TE) + restaura??o com resina composta Z250 (RC); MOD + TE + cimento de ion?mero de vidro Riva Light Cure (GI); MOD + TE + Cimento de ion?mero de vidro Riva Silver (GIS); MOD + TE + pino de fibra de vidro transfixado (TFP) + RC (RCP); GI + TFP (GIP); GIS + TFP (GISP). Os preparos cavit?rios MOD foram padronizados com largura 2/3 da dist?ncia vest?bulo-lingual, tendo como refer?ncia a ponta das respectivas c?spides, e profundidade ocluso-gengival de 4mm permanecendo 2mm acima do limite amelo-cement?rio. Foram realizados tratamentos endod?nticos em todos os grupos, exceto para o grupo dos dentes h?gidos. Os grupos (RCP), (GIP) e (GSIP) receberam pinos de fibra de vidro transfixados horizontalmente e ap?s foram restaurados com Z250, Riva Light Cure ou Riva Silver, respectivamente. Ap?s, os dentes foram submetidos ao ensaio de resist?ncia ? fratura em uma m?quina de ensaio universal. Ap?s realiza??o dos ensaios, os dentes foram inspecionados quanto ao tipo de fratura e classificados em: Fratura em assoalho pulpar (N?o recuper?vel) ou C?spide (Recuper?vel). Resultados: M?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey (p>0,05): (H) 3901NA; (RC) 1232NB; (GI) 1251NB; (GIS) 1259NB; (GISP) 2168NC; (RCP) 2230NC; (GIP) 2292NC. O padr?o predominante de fratura foi em c?spide. Conclus?es: A utiliza??o do pino de fibra de vidro restaurado com resina composta (RCP), Riva Light Cure (GIP) e Riva Silver (GISP) recuperou, respectivamente, 57,16%, 58,75% e 55,56% da resist?ncia ? fratura de um dente h?gido, enquanto os dentes restaurados sem pino recuperaram para os grupos (RC), (GI) e (GIS), 31,53%, 32,07% e 34,84%. O progn?stico predominante foi recuper?vel para todos os grupos, exceto (GIS). / Objectives: 1) To assess the fracture strength of third molars with endodontically treated MOD cavity preparations and restored with direct composit resin, resin modified glass ionomer cement or silver glass ionomer cement with and without the presence of fiberglass post transfixed horizontally in endodontically treated molars; 2) To assess the fracture pattern of the teeth after the fracture resistance test. Materials and Methods: Seventy extracted healthy third molars were embedded in acrylic resin and divided into 7 groups (n = 10 per group): Healthy (H); Cavity preparation (MOD) + Endodontic treatment (ET) + restoration with Z250 composit resin (RC); MOD + TE + glass ionomer cement Riva Light Cure (GI); MOD + TE + Riva Silver glass ionomer cement (GIS); MOD + TE + transfixed fiberglass post (TFP) + RC (RCP); GI + TFP (GIP); GIS + TFP (GISP); MOD cavity preparations were standardized with a width of 2/3 fo the vestibular-lingual distance, with reference to the tip of the respective cusps, and occlusal-gingival depth of 4mm remaining 2mm above the cemento-enamel junction. Endodontic treatments were performed in all groups, except for the healthy teeth group. The groups (RCP), (GIP) and (GISP) received horizontally transfixed fiberglass posts and afterwards were restored with Z250, Riva Light Cure or Riva Silver, respectively. Afterwards, the teeth were submitted to the fracture strength test in a universal test machine. After the tests were performed, the theeth were inspected for the type of fracture and classified as: Fracture in the pulpal floor (Not-recoverable) or cusps (Recoverable) Results: Averages followed by the same letter did not present statistical difference for ANOVA and Tukey (p>0,05): (H) 3901NA; (RC) 1232NB; (GI) 1251NB; (GIS) 1259NB; (GISP) 2168NC; (RCP) 2230NC; (GIP) 2292NC. The predominant pattern of fracture was cusps. Conclusions: The use of the fiberglass post restored with composite resin (RCP), Riva Light Cure (GIP) and Riva Silver (GISP) recovered, respectively 57.16%, 58.75% and 55.56% of resistance to the fracture of a healthy tooth, whereas the restored teeth without post recovered for the groups (CR), (GI) and (GIS), 31.35%, 32.07% and 34.84%. The predominant prognosis was recoverable for all groups, except (GIS). / Objetivos: 1) To assess the fracture strength of endodontically treated molars with MOD cavity preparations and restored with Riva Light Cure (RLC) ou Riva Silver (RS) with and without the presence of transfixed fiberglass post associated with Bulk Fill Flow resin; 2) To assess the fracture pattern after the mechanical test. Materials and Methods: Fifty third molars extracted were divided into 5 groups (n = 10 per group): Healthy (H); Preparation MOD (MOD) + Endodontic Treatment (TE) + glass ionomer cement Riva Light Cure (GI); MOD + TE + Riva Silver glass ionomer cement (GIS); MOD + TE + BulkFill Flowable resin (BFF) + horizontal fiberglass post (TFP) + RLC (GIP); MOD + TE + BFF + RS (GISP). MOD cavity preparations and endodontic treatments were performed in all groups, except for the healthy ones. The vestibular and palatine face of the (GIP) and (GISP) groups received the horizontal transfixation of the fiberglass post followed by the insertion of the composite resin Bulk Fill Flow, Riva Light Cure or Riva Silver according to the study groups. The teeth were submitted to the fracture strength test in a universal test machine. The type of fracture after the test was classified as: pulpal floor fracture (condemned) or cuspal fracture(recoverable). Results: Averages in Newtons (N) followed by the same letter did not present statistical difference for ANOVA and Tukey (P<0,05%): H 3955,6NA; GI 1215,6NB; GIS 1195,8NB; GIP 2064,6NC GISP 2386,5NC. The fracture pattern was similar between the groups tested with 54% of recoverable fractures and 46% for condemned teeth. Conclusions: The association of fiberglass post, BulkFill Flowable resin, Riva Light Cure (GIP) ou Riva Silver (GISP) recovered respectively 52.19% and 60.23% of the fracture resistance of a healthy tooth, being, on overage, 2x greater than the results of the groups (GI) and (GIS).
127

Efeito do plasma rico em plaquetas no reparo do tend?o de aquiles em ratos

Dietrich, Franciele 26 July 2017 (has links)
Submitted by PPG Medicina e Ci?ncias da Sa?de (medicina-pg@pucrs.br) on 2017-11-23T10:48:18Z No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2017-12-01T11:50:39Z (GMT) No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) / Made available in DSpace on 2017-12-01T11:54:10Z (GMT). No. of bitstreams: 1 FRANCIELE_DIETRICH_TES.pdf: 3499792 bytes, checksum: c6cf1d1c8ad84ed3af5c5b4a075c3eb9 (MD5) Previous issue date: 2017-07-26 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The increasing incidence of tendon injuries is a constant challenge in orthopaedic medicine. The use of platelet-rich plasma (PRP) is a strategy widely explored in the clinic because it is believed to accelerate the tendon repair process. However, the PRP clinical efficacy is uncertain, and more studies that aim to a better understanding of this treatment are needed. The aim of this research was to evaluate the PRP effect on the Achilles tendon (AT) repair of rats. A total of 242 rats were used, where 181 animals were randomly distributed in 6 different experiments. The remaining animals were used as blood donors (n=49) and for flow cytometry (n=12). The lesion was performed by transection of the right AT. The repair evaluation occurred after 11 and 14 postoperative days, with a mechanical testing machine. Peak force was considered the primary variable. Variations in the PRP production protocols, leukocyte concentration and physical activity of the rats were tested. ELISA test was performed to quantify platelet-derived growth factor (PDGF-AB) present in PRP. Pathogenfree animals and animals contaminated with Staphylococcus aureus (S. aureus) were used. Standard PRP platelet concentration was at least 5 times higher than that of the peripheral blood, and it was possible to have either a high or a low leukocyte concentration in the preparation. PDGF-AB levels in inactivated PRP were 7.3 ?g/mL (SD 6.0; n=4) and in plasma were below the detection levels (0.03 ng/mL). In the experiments performed with pathogen-free rats, no significant effect of PRP could be observed on tendon repair. In the same way, no significant difference could be found in the rats treated with PRP with higher or lower leukocyte concentration. In contrast, rats contaminated with S. aureus showed increased tendon force after PRP treatment. Significant interaction between bacteriological status and PRP treatment was verified (p=0.003). It was further observed that healthy rats had higher levels of cytotoxic T cells in their spleens. The difference in response to treatment in contaminated rats suggests that the PRP effect is dependent on the immune status of the animals. This is the first study that suggests the possibility of interaction between microbiota and tendon repair. Extrapolation of this treatment to the clinic remains dubious. / A crescente incid?ncia de les?es tend?neas constituem um desafio constante na medicina ortop?dica. A utiliza??o do plasma rico em plaquetas (PRP) ? uma estrat?gia amplamente explorada na cl?nica por creditar-se que acelera o processo de reparo tend?neo. Contudo, a efic?cia cl?nica do PRP ? question?vel, e mais estudos que visem uma melhor compreens?o deste tratamento s?o necess?rios. O objetivo desta pesquisa foi avaliar o efeito do PRP no reparo do tend?o de Aquiles (TA) de ratos. Um total de 242 ratos foram utilizados, sendo 181 animais randomicamente distribu?dos em 6 diferentes experimentos. Os animais restantes foram utilizados como doadores sangu?neos (n= 49) e para realiza??o de citometria de fluxo (n=12). A les?o foi executada atrav?s de transec??o do TA direito. A avalia??o do reparo foi feita 11 e 14 dias p?s-cir?rgico, atrav?s de m?quina de teste mec?nico. O pico de for?a foi considerado a vari?vel principal. Varia??es no protocolo de produ??o de PRP, concentra??o de leuc?citos e atividade f?sica dos ratos foram testados. O teste de ELISA foi realizado a fim de quantificar o fator de crescimento derivado das plaquetas (PDGF-AB) presente no PRP. Foram utilizados animais livres de pat?genos e animais contaminados com Staphylococcus aureus (S. aureus). A concentra??o plaquet?ria do PRP padr?o foi pelo menos 5 vezes maior que a do sangue perif?rico, e foi poss?vel obtermos tanto uma alta ou baixa concentra??o de leuc?citos no preparado. Os n?veis de PDGF-AB no PRP inativado foram de 7.3 ?g/mL (DP 6.0; n=4) e no plasma sangu?neo foram abaixo dos n?veis de detec??o (0.03 ng/mL). Nos experimentos realizados com ratos livres de pat?genos, nenhum efeito significativo do PRP p?de ser observado no reparo tend?neo. Da mesma forma, nenhuma diferen?a significativa p?de ser encontrada nos ratos tratados com PRP com alta ou baixa concentra??o de leuc?citos. Em contraste, os ratos contaminados com S. aureus demonstraram aumento da for?a tend?nea ap?s o tratamento com PRP. Significante intera??o entre estado bacteriol?gico e tratamento PRP foi verificada (p=0.003). Observou-se ainda, que ratos saud?veis possu?am maiores n?veis de c?lulas T citot?xicas em seus ba?os. A diferen?a na resposta ao tratamento em ratos contaminados sugere que o efeito do PRP ? dependente do estado imune dos animais. Esse ? o primeiro estudo que sugere a possibilidade de intera??o entre microbiota e reparo tend?neo. A extrapola??o deste tratamento para a cl?nica permanece d?bia.
128

Elucida??o do mecanismo de resist?ncia de Mycobacterium tuberculosis frente a novos compostos com atividade antimicobacteriana

Abbadi, Bruno Lopes 19 January 2018 (has links)
Submitted by PPG Biologia Celular e Molecular (bcm@pucrs.br) on 2018-03-05T13:21:28Z No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-03-06T16:15:19Z (GMT) No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) / Made available in DSpace on 2018-03-06T16:21:42Z (GMT). No. of bitstreams: 1 BRUNO_LOPES_ABBADI_TES.pdf: 4934736 bytes, checksum: 58e4c3c86d9fb96bb1476ae3c18bfdf0 (MD5) Previous issue date: 2018-01-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Epidemiologic data regarding tuberculosis (TB) show that there is still a high burden of this disease worldwide. In addition, the emergence of drug-resistant strains imposes a new threat in preventing TB spread. Therefore, it is pivotal to continuously find new candidates for drug development. In the Chapter 2 of this thesis, the compound IQG-607 is presented, which is a metal complex that has been reported as a promising anti-TB molecule against isoniazid (INH)-resistant strains of M. tuberculosis. Previous studies suggested that the compound inhibits both the wild-type NADH-dependent trans-2-enoyl-[ACP] reductase (InhA) enzyme and some of its structural mutants in the absence of NAD+ or NADH and without requiring KatG enzyme. IQG-607 has also shown a favorable toxicological profile in vivo, with a considerable lesser toxicity compared to INH. However, there is still a gap regarding the activity of IQG-607 against strains carrying mutations in the katG gene, which are the most common genetic alterations in clinical isolates resistant to INH. Therefore, this study focused in elucidating the mechanism of resistance (MOR) of the Mycobacterium tuberculosis, the main causative agent of TB, to compound IQG-607. First the minimum inhibitory concentration (MIC) of IQG-607 was established against eight multi-drug resistant (MDR) clinical isolates, which were resistant to our compound. Then spontaneous mutants were selected using high concentrations of compound in 7H10 agar medium, and their whole genomes were sequenced; the results revealed alterations in the katG gene. A laboratory strain carrying the mutant katG(S315T) gene was developed to assess the effect of this single mutation in the compound activity both by MIC determination and by a macrophage infection model. Results showed that this mutation was indeed sufficient to confer resistance to IQG-607. Finally, the resistance observed for a strain expressing a mutant InhA(S94A) protein suggested that IQG-607 has this enzyme as its molecular target. In the Chapter 3, two new compounds, called Labio-16 and Labio-17, are presented, which were previously selected to interact and inhibit the InhA enzyme and that had already shown to be active against M. tuberculosis H37Rv strain. A set of experiments were conducted to elucidate their mechanism of action (MOA) and to understand the MOR of the M. tuberculosis against them, similar to those carried for studying IQG-607. So far, results suggested that the InhA is not the molecular target of these compounds. Other experiments are undergoing in our laboratory to evaluate in a murine model of TB infection their potential as anti-TB drug candidates. / Os dados epidemiol?gicos relacionados ? tuberculose (TB) indicam que ainda existe uma carga elevada desta doen?a no mundo todo. Al?m disso, o surgimento de cepas resistentes aos f?rmacos imp?e uma nova amea?a na preven??o da propaga??o da TB. Portanto, ? fundamental buscar continuamente novos candidatos para o desenvolvimento de medicamentos. No Cap?tulo 2 desta tese ? apresentado o composto IQG-607, que ? um complexo met?lico que tem sido reportado como uma mol?cula anti-TB promissora contra cepas de M. tuberculosis resistentes ? isoniazida (INH). Estudos pr?vios sugeriram que o composto inibe a enzima selvagem trans-2-enoil-[ACP] redutase dependente de NADH (InhA) e algumas das suas mutantes estruturais, na aus?ncia de NAD+ ou NADH e sem necessitar da enzima KatG. O IQG-607 tamb?m mostrou um perfil toxicol?gico favor?vel in vivo, com uma menor toxicidade em compara??o ? INH. No entanto, ainda existe uma lacuna em rela??o ? atividade do IQG-607 contra cepas que carregam muta??es no gene katG, as quais s?o as altera??es gen?ticas mais comuns em isolados cl?nicos resistentes ? INH. Sendo assim, este estudo focou em elucidar o mecanismo de resist?ncia (MOR) do Mycobacterium tuberculosis, o principal agente causador da TB, ao composto IQG-607. Primeiramente, a concentra??o inibit?ria m?nima (MIC) do IQG-607 foi estabelecida contra oito isolados cl?nicos multirresistentes a f?rmacos (MDR), os quais foram resistentes ao nosso composto. Ent?o, mutantes espont?neos foram selecionados, usando-se altas concentra??es do composto em meio ?gar 7H10, e seus genomas completos foram sequenciados; os resultados revelaram altera??es no gene katG. Uma cepa laboratorial, carregando o gene katG(S315T) mutante, foi desenvolvida para acessar o efeito desta ?nica muta??o na atividade do composto, atrav?s da determina??o de MIC e por meio de um modelo de infec??o de macr?fagos. Os resultados mostraram que essa muta??o de fato foi suficiente para conferir resist?ncia ao IQG-607. Finalmente, a resist?ncia observada para a cepa que expressa a prote?na InhA(S94A) mutante sugeriu que o IQG-607 tem esta enzima como seu alvo molecular. No Cap?tulo 3, dois novos compostos, denominados Labio-16 e Labio-17, s?o apresentados, os quais foram previamente selecionados para interagir e inibir a enzima InhA, e que j? tinham mostrado ser ativos contra a cepa H37Rv de M. tuberculosis. Um conjunto de experimentos foi conduzido para elucidar os seus mecanismos de a??o (MOA) e para compreender o MOR do M. tuberculosis contra eles, similar ?quele usado para estudar o IQG-607. At? o momento, os resultados sugerem que a InhA n?o ? o alvo molecular desses compostos. Outros experimentos est?o em andamento em nosso laborat?rio, para avaliar em um modelo murino da infec??o da TB os seus potenciais como candidatos a f?rmacos anti-TB.
129

Identifica??o e determina??o de resist?ncia antimicrobiana em isolados nosocomiais de Acinetobacter baumannii

Raro, Ot?vio Hallal Ferreira 30 September 2011 (has links)
Made available in DSpace on 2015-04-14T14:51:15Z (GMT). No. of bitstreams: 1 437674.pdf: 1507951 bytes, checksum: 2f5468fe0bdb2401a723df07c96e2c43 (MD5) Previous issue date: 2011-09-30 / Acinetobacter baumannii is an important opportunistic pathogen commonly associated with nosocomial infections, especially in patients hospitalized in intensive care units (ICUs). This microorganism is renowned for its ability to survive under adverse conditions in the environment for extended periods, as well as to rapidly acquire resistance to antimicrobial drugs. Nowadays, the increasing antimicrobial resistance of A. baumannii has been a great challenge for the medical community, since there are few effective options for the treatment of infections caused by this organism. The aim of this study was to evaluate the presence of the A. baumannii from an ICU environment and to characterize the antimicrobial drug resistance of the isolates obtained, as well as of the isolates from patients in ICU of the same hospital in which it was collected environmental samples. For this, 886 environmental and gloves samples were collected from an ICU of S?o Lucas Hospital, Porto Alegre, Brazil, and 46 clinical isolates were obtained from the Laboratory of the same hospital. After the identification of the isolates as A. baumannii by PCR using as target 16S rDNA and blaOXA-51 genes, the resistance to 20 antimicrobial drugs and the production of metallo-beta-lactamases were evaluated in isolates presenting carbapenem reduced susceptibility. Also, it was evaluated the presence of integrons and blaOXA-23 and blaIMP genes by PCR. A. baumannii was identified in 9.6% of environmental and glove samples collected. High percentage of multiresistant (MDR) isolates was found, as well as it was detected high rates of reduced susceptibility to carbapenems. All 89 isolates integron positive were MDR. Between isolates with reduced susceptibility to carbapenems, all presented blaOXA-23, and 41.4% non-clinical and 54% clinical carried the blaIMP. High resistance to polymyxin B was detected, mainly in non-clinical isolates. Although high prevalence has been found in clinical and non-clinical isolates, the latter constitute a great concern, because they can indicate the hospital environment as a reservoir of MDR A. baumannii. / Acinetobacter baumannii ? um importante pat?geno oportunista comumente associado a infec??es nosocomiais, especialmente em pacientes hospitalizados em unidades de tratamento intensivo (UTIs). Este organismo ? reconhecido por sua capacidade de sobreviver em condi??es adversas no ambiente por per?odos prolongados, bem como de facilmente adquirir resist?ncia a drogas antimicrobianas. Atualmente, a crescente resist?ncia antimicrobiana de A. baumannii tem constitu?do um grande desafio para a comunidade m?dica, uma vez que existem poucas op??es efetivas para o tratamento de infec??es causadas por este microrganismo. O objetivo deste estudo foi avaliar a presen?a de A. baumannii no ambiente de uma UTI e caracterizar a resist?ncia a drogas antimicrobianas dos isolados obtidos, bem como de isolados de pacientes internados na UTI do mesmo hospital no qual as amostras ambientais foram coletadas. Para tanto, 886 amostras ambientais e de luvas foram coletadas de uma UTI do Hospital S?o Lucas, Porto Alegre, Brasil, e 46 isolados cl?nicos foram obtidos no Laborat?rio do mesmo hospital. Ap?s a identifica??o dos isolados como A. baumannii atrav?s de PCR utilizando como alvos os genes rDNA 16S e blaOXA-51, foram determinadas a resist?ncia a 20 drogas antimicrobianas previstas pelo CLSI e a produ??o de metalo-betalactamases em isolados com suscetibilidade reduzida aos carbapen?micos. Tamb?m foi avaliada a presen?a de integrons e dos genes blaOXA-23 e blaIMP atrav?s de PCR. A. baumannii foi identificado em 9,6% das amostras ambientais e de luvas coletadas. Obteve-se um alto percentual de isolados multirresistentes (MDR), assim como foram detectadas alta taxas de suscetibilidade reduzida aos carbapen?micos. Todos os 89 isolados que apresentaram integrons foram MDR. Dentre os isolados com suscetibilidade reduzida aos carbapen?micos, todos apresentaram o gene blaOXA-23, e 41,4% n?o-cl?nicos e 54% cl?nicos carrearam o gene blaIMP. Alta resist?ncia ? polimixina B foi detectada, principalmente em isolados n?o-cl?nicos. Embora alta preval?ncia de resist?ncia antimicrobiana tenha sido encontrada em isolados cl?nicos e n?o cl?nicos, os ?ltimos constituem grande preocupa??o, pois podem indicar o ambiente hospitalar como um reservat?rio de A. baumannii MDR.
130

Avalia??o do potencial de utiliza??o do tanino vegetal da ac?cia negra como inibidor do processo de corros?o de a?o ao carbono em presen?a de CO2 a alta press?o

Marcolino, Juliane Bernardes 31 March 2015 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2015-08-26T12:43:16Z No. of bitstreams: 1 474158 - Texto Completo.pdf: 30740052 bytes, checksum: 0b50c4fe801d696f16180d6fa641a96c (MD5) / Made available in DSpace on 2015-08-26T12:43:16Z (GMT). No. of bitstreams: 1 474158 - Texto Completo.pdf: 30740052 bytes, checksum: 0b50c4fe801d696f16180d6fa641a96c (MD5) Previous issue date: 2015-03-31 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / In this work, it was evaluated the possibility of using bark of black wattle (Acacia mearnsii) as a corrosion inhibitor in environments with presence of CO2 under high pressure. SAE 1010 carbon steel samples were exposed to two corrosive situations (with and without oxygen) under the conditions of 15 MPa and 70 ?C, with distinct tannin concentrations for different exposure times (168, 360 and 2160 hours). In order to characterize the specimens it was used infrared spectroscopy analysis, Xray diffraction, scanning electron microscopy by field emission, energy dispersive spectroscopy, mass loss and potentiodynamic polarization tests, determining the rate of corrosion and the efficiency tannin as of tannin as inhibitor. The results indicated that the tannin in deaerated environmental has no potential for use as an inhibitor once there was no significant reduction in corrosion rates and, also the formation of ferric-tannates film. Was not observed corrosion rates values, due mass loss, and were classified as severe corrosion, according to values of NACE RP-07-75 and was not inhibition efficiency values higher than 21 % obtained. Nevertheless, in aerated environmental, tannin worked as a barrier to diffusion of O2 and/or complexation of Fe2+ and Fe3+, providing favorable conditions to the formation of FeCO3 film with protective features. The corrosion rates were classified as moderate for 2160 hours, while 168 h and 360 h, as severe, also according to the values of NACE-RP-07-75, reaching values of up to 72% inhibition efficiency. / Neste trabalho, avaliou-se a possibilidade de utiliza??o do tanino vegetal da ac?cia negra (Acacia mearnsii) como inibidor de corros?o em ambientes com a presen?a de CO2 a alta press?o. Corpos de prova de a?o SAE 1010 foram expostos a dois meios corrosivos (sem e com O2) sob condi??es de 15 MPa e 70?C, com diferentes concentra??es de tanino para diferentes tempos de exposi??o (168, 360 e 2160 h). Para caracteriza??o foram realizadas an?lises de espectroscopia de infravermelho, difra??o de raios X, microscopia eletr?nica de varredura por emiss?o de campo, espectroscopia de energia dispersiva, perda de massa e ensaios de polariza??o potenciodin?mica, determinando-se a taxa de corros?o e a efici?ncia do tanino como inibidor. Os resultados indicaram que o tanino, em meio desaerado, n?o apresenta potencial para utiliza??o como inibidor, pois n?o houve redu??o significativa nas taxas de corros?o e tamb?m n?o se observou a forma??o do filme de ferrotanatos. Todos os valores de taxas de corros?o, por perda de massa, foram classificados como corros?o severa, segundo valores da NACE-RP-07-75 e n?o se obteve valores de efici?ncia de inibi??o maiores que 21 %. No entanto, em meio aerado, o tanino atuou como barreira para a difus?o de O2 e/ou na complexa??o dos ?xidos de Fe2+ e Fe3+, formando filmes de ferrotanatos, propiciando condi??es favor?veis para a forma??o do filme de FeCO3 com caracter?sticas protetoras. As taxas de corros?o foram classificadas como moderada para 2160 h, enquanto que para 168 h e 360 h, como severa, tamb?m segundo valores da NACE-RP-07-75, atingindo-se valores de at? 72 % de efici?ncia de inibi??o.

Page generated in 0.0475 seconds