1 |
Avaliação do desgaste das lâminas de corte do sistema Reciproc através da utilização do microscópio eletrônico de varredura MEV / Evaluation of wear of the cutting blades Reciproc system using the scanning electron microscope SEMFrança, Rodrigo Casasanta 20 August 2013 (has links)
Quando se utilizam os instrumentos rotatórios, oscilatórios e os recíprocos, de NiTi (Níquel-Titânio), cortando ou raspando as paredes do conduto radicular, estes também sofrem desgastes em suas lâminas de corte. Tal ocorrência determina atritos cada vez maiores, proporcionais à perda do corte de suas lâminas, diminuindo a eficiência do instrumento, exigindo mais torques e força de penetração, aumentando ainda mais o atrito e o esforço que este sofre para desgastar a dentina, predispondo acidentes. O presente estudo avaliou o desgaste nas lâminas de corte das limas Reciproc, após 3,6 e 9 usos em canais de dentes naturais. Foram utilizados 180 dentes pré-molares inferiores e 40 instrumentos R40. Após o preparo dos canais os instrumentos foram incluídos em corpos de prova e submetidos a cortes transversais a 3 mm e 6 mm, contados a partir da ponta do instrumento. Nas imagens dessas secções transversais obtidas no MEV foi mesurada a distância entre as extremidades das lâminas de corte. O desgaste dos instrumentos foi estabelecido pela diferença entre as medidas das distâncias dos instrumentos sem uso com a média de cada instrumento, nos diferentes grupos experimentais. Observou-se diferença significante, quando comparados os grupos de 6 e 9 usos com o grupo controle. Já o grupo com 3 utilizações não apresentou diferença estatisticamente significante em relação ao grupo controle. As diferenças percentuais de desgaste a 3 mm após 3, 6 e 9 utilizações foram de 5,96%, 8,01% e 18,09%, respectivamente, em relação ao Grupo controle. As diferenças percentuais de desgaste a 6 mm, após 3, 6 e 9 utilizações foram de 2,32%, 9,54% e 21,00%, respectivamente, em relação ao Grupo controle. Conclui-se, assim, que ocorre desgaste significante das lâminas de corte dos instrumentos Reciproc, já a partir do terceiro uso reforçando a recomendação do fabricante em utilizar cada instrumento em molar e, então, descartá-lo. Palavras-chave: Microscopia eletrônica de varredura. Sistema Rotatório. / The fracture of nickel-titanium instrument, whose consequences can range from the difficulty of its removal until the absolute inaccessibility to the apical portion of the canal, remains a situation to be avoided in the safest way possible. When using the rotary instruments, and reciprocal oscillatory, NiTi, cutting or scraping the walls of the root canal, they also suffer wear in its cutting blades. Such an occurrence determines friction increasing in proportion to the loss of cutting blades, reducing the efficiency of the instrument, requiring higher torque and penetration force, further increasing friction and effort that suffers when wearing the dentin. Different rotational speeds to the long axis of the active part of the instrument are thus provoked in areas of high friction, favoring fractures, regardless of the type of movement, even if it is rotating or reciprocating. The present study sought to assess whether there is wear on cutting blades System Reciproc, since this system works through reciprocal movement within the root canal. For that, we will instrumentation in selected teeth with the kinematic system recommended by the manufacturer at zero, three, six and nine uses, corresponding to a molar tooth, two molar teeth and three molar teeth after 10 uses in each experimental group (zero , three, six and nine) according to the number of uses. The instruments are inserted into a quadrangular centralized device in the same position, and fixed in resin, which have been cut into their cross initial 3 mm and 6 mm initial these selected samples with the cross section of the system is brought to the SEM, and thus wear measured by measuring the radius of your cutting blades, and thus statistically analyzed. The results showed statistically significant differences after successive instrumentations.
|
2 |
Avaliação do desgaste das lâminas de corte do sistema Reciproc através da utilização do microscópio eletrônico de varredura MEV / Evaluation of wear of the cutting blades Reciproc system using the scanning electron microscope SEMRodrigo Casasanta França 20 August 2013 (has links)
Quando se utilizam os instrumentos rotatórios, oscilatórios e os recíprocos, de NiTi (Níquel-Titânio), cortando ou raspando as paredes do conduto radicular, estes também sofrem desgastes em suas lâminas de corte. Tal ocorrência determina atritos cada vez maiores, proporcionais à perda do corte de suas lâminas, diminuindo a eficiência do instrumento, exigindo mais torques e força de penetração, aumentando ainda mais o atrito e o esforço que este sofre para desgastar a dentina, predispondo acidentes. O presente estudo avaliou o desgaste nas lâminas de corte das limas Reciproc, após 3,6 e 9 usos em canais de dentes naturais. Foram utilizados 180 dentes pré-molares inferiores e 40 instrumentos R40. Após o preparo dos canais os instrumentos foram incluídos em corpos de prova e submetidos a cortes transversais a 3 mm e 6 mm, contados a partir da ponta do instrumento. Nas imagens dessas secções transversais obtidas no MEV foi mesurada a distância entre as extremidades das lâminas de corte. O desgaste dos instrumentos foi estabelecido pela diferença entre as medidas das distâncias dos instrumentos sem uso com a média de cada instrumento, nos diferentes grupos experimentais. Observou-se diferença significante, quando comparados os grupos de 6 e 9 usos com o grupo controle. Já o grupo com 3 utilizações não apresentou diferença estatisticamente significante em relação ao grupo controle. As diferenças percentuais de desgaste a 3 mm após 3, 6 e 9 utilizações foram de 5,96%, 8,01% e 18,09%, respectivamente, em relação ao Grupo controle. As diferenças percentuais de desgaste a 6 mm, após 3, 6 e 9 utilizações foram de 2,32%, 9,54% e 21,00%, respectivamente, em relação ao Grupo controle. Conclui-se, assim, que ocorre desgaste significante das lâminas de corte dos instrumentos Reciproc, já a partir do terceiro uso reforçando a recomendação do fabricante em utilizar cada instrumento em molar e, então, descartá-lo. Palavras-chave: Microscopia eletrônica de varredura. Sistema Rotatório. / The fracture of nickel-titanium instrument, whose consequences can range from the difficulty of its removal until the absolute inaccessibility to the apical portion of the canal, remains a situation to be avoided in the safest way possible. When using the rotary instruments, and reciprocal oscillatory, NiTi, cutting or scraping the walls of the root canal, they also suffer wear in its cutting blades. Such an occurrence determines friction increasing in proportion to the loss of cutting blades, reducing the efficiency of the instrument, requiring higher torque and penetration force, further increasing friction and effort that suffers when wearing the dentin. Different rotational speeds to the long axis of the active part of the instrument are thus provoked in areas of high friction, favoring fractures, regardless of the type of movement, even if it is rotating or reciprocating. The present study sought to assess whether there is wear on cutting blades System Reciproc, since this system works through reciprocal movement within the root canal. For that, we will instrumentation in selected teeth with the kinematic system recommended by the manufacturer at zero, three, six and nine uses, corresponding to a molar tooth, two molar teeth and three molar teeth after 10 uses in each experimental group (zero , three, six and nine) according to the number of uses. The instruments are inserted into a quadrangular centralized device in the same position, and fixed in resin, which have been cut into their cross initial 3 mm and 6 mm initial these selected samples with the cross section of the system is brought to the SEM, and thus wear measured by measuring the radius of your cutting blades, and thus statistically analyzed. The results showed statistically significant differences after successive instrumentations.
|
3 |
Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instrumentsSá, Júnio Pereira de 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
|
4 |
Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instrumentsJúnio Pereira de Sá 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
|
5 |
Avaliação por meio da microscopia eletrônica de varredura da limpeza e deformação de instrumentos rotários após a instrumentação de canais radiculares / Evaluation by scanning electron microscopy of cleaning and deformation of rotary instruments after useConsolmagno, Elaine Cristina 21 November 2011 (has links)
O presente estudo teve como objetivo avaliar, por meio da microscopia eletrônica de varredura (M.E.V.), a remoção de detritos e deformação superficial sofrida pelos sistemas endodônticos rotatórios de NiTi BioRace (BR); Protaper (PT) e Twisted File (TF) após cada uso, totalizando cinco usos, simulando as condições clínicas. Um total de 75 molares superiores humanos extraídos cuja raiz disto-vestibular apresentava curvatura de 0 a 5° e mésio-vestibular entre 20 e 30° de acordo com o método de Weine, foram selecionados e divididos em três grupos com 25 espécimes. Para o grupo I: realizou-se instrumentação com o sistema BR; para o grupo II com o sistema PT e para o grupo III, com o TF. Foram utilizadas cinco caixas de cada sistema rotatório para instrumentar os canais mesio e distovestibulares. Inicialmente os instrumentos foram fotografados em M.E.V. com aumento de 35 vezes, utilizados uma vez e em seguida passaram por um protocolo de limpeza baseado no proposto por Parashos, Linsuwanont e Messer (2004) previamente a esterilização e, em seguida eram analisados em M.E.V., antes do uso seguinte. Esses procedimentos foram realizados até o último uso. Os dados de limpeza foram submetidos ao teste estatístico de Kruskal Wallis para comparação global e ao teste de Dunn para comparação individual dos grupos, enquanto para análise da deformação foram submetidos ao teste estatístico do Qui-quadrado para comparação global e ao teste exato de Fisher para as comparações individuais, todos com significância de 5%. Os resultados apontaram diferenças estatisticamente significantes quanto à limpeza para o sistema BR com maior quantidade de detritos remanescentes do processo de fabricação em relação ao PT e TF; após os 5 usos, os sistemas BR e PT apresentavam-se mais limpos em relação ao início do experimento, enquanto o TF permaneceu com quantidade semelhante de detritos superficiais. Ocorreu deformação em 40% do sistema BR, sendo 5% fratura e, 100% do TF, sendo 40% fratura. O sistema PT não sofreu danos consideráveis de acordo com os critérios avaliados. Por meio dos resultados obtidos neste estudo, concluiu-se que o protocolo de limpeza utilizado não proporcionou superfícies completamente limpas tanto no decorrer quanto ao final do experimento e quanto a deformação superficial, o sistema TF apresentou o pior resultado, seguido do BR, enquanto o PT que não apresentou qualquer deformação quanto aos critérios avaliados. / The aim of this study was to evaluate by scanning electron microscopy (SEM) the debris removal and deformation surface by rotary NiTi endodontic systems BioRace (BR), Protaper (PT) and Twisted File (TF) before each use, total five uses, simulating clinical conditions. A total of 75 extracted human molars whose disto-vestibular roots had curvature between 0 and 5 degrees and mesio-vestibular roots had curvature between 20 and 30 degrees according to the Weine method were selected and divided into three groups of 25 specimens. In the Group I: was used the BR system, group II was used the PT system and group III was used the TF system to shaping the mesio and distovestibular molars canals. Were used a total of five boxes to each rotary system. Initially, the instruments were examined by SEM at a magnification of 35x, then used into root canals and submitted through the cleaning protocol based on proposed by Parashos, Linsuwanont and Messer (2004) prior to sterilization for further examination by SEM, before the next use. These procedures were carried out until the last use. The cleaning data were analysed using statistical Kruskal Wallis test for global comparison and the Dunn test for individual groups comparison. The deformation data were analysed using Chi-square test for overall comparison and Fisher exact test for individual comparisons, both with 5% significance. The results showed the following statistically significant differences regarding cleaning to BR system with highest amount of debris remaining from the manufacturing process in relation to the PT and TF; after the five uses, the BR and PT systems were cleaner in relation to the initial experiment, but the TF system had the same debris amount. The deformation occurred in 40% of the BR system, with 5% fractured and 100% of the TF, with 40% fractured. The PT system has not suffered considerable damage in accordance with the criteria evaluated. The results of this study showed that the protocol did not provide cleaning surfaces completely free of debris, especially in the TF system, while for the BR and PT, resulting in cleaner surfaces at the end of the experiment compared with the dirt initial (immediately removed from their packaging). The surface deformation of TF system presented the worst results, followed by the BR and PT did not show any deformation on the criteria evaluated.
|
6 |
Avaliação microbiológica e quantificação de raspas extruídas por instrumentos reciprocantes e rotatórios com variação no calibre e na irrigação ultrassônica passiva / Microbiological evaluation and quantification of extruded debris by reciprocating and rotating instruments with variation in caliber and passive ultrasonic irrigationCardenas Cuellar, Maricel Rosario 28 March 2018 (has links)
Foi objetivo deste estudo, avaliar comparativamente o volume dos debris e a extrusão bacteriana apical durante o preparo de canais radiculares com os instrumentos Prodesign R e Prodesign Logic, com diferentes calibres e presença de irrigação ultrassônica passiva (PUI) ou não, em dentes contaminados com Enterococcus faecalis (ATCC29212). Métodos: Foram empregados 90 pré-molares inferiores, decoronados e padronizados em 16 mm, divididos em 8 grupos (n=10) segundo os sistemas a serem empregados; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 e 35.05, e o tipo de ativação do irrigante, contaminados durante 5 dias. Debris extruídos foram coletados em microtubos vazios pesados previamente 3 vezes, inseridos na parte inferior de um dispositivo metálico para uma posterior pesagem dos debris. Também foram realizadas coletas dos canais e dos debris extruídos para uma avaliação microbiológica através da contagem das unidades formadoras de colônias (UFC/mL). Resultados: O tipo de movimento rotatório e reciprocante e o diâmetro do calibre, 25 ou 35, não mostraram diferenças entre si (P>0.05). Comparando a irrigação convencional com o emprego do ultrassom, este último promoveu uma maior quantidade de debris extruídos pelo forame (P<0.05). Na análise microbiológica das coletas dos debris, o sistema Prodesign Logic 25 promoveu uma maior quantidade de raspas contaminadas (P<0.05). Nas coletas dos canais tanto a irrigação convencional quanto o uso do ultrassom mostraram uma diminuição das UFC/mL das coletas iniciais comparadas com as finais, sem diferença estatística (P<0.05). A contaminação microbiana nas raspas extruídas foi menor no grupo onde foi empregada a irrigação convencional (P<0.05). Conclusões: Os calibres dos instrumentos e o tipo de movimento utilizado nos canais radiculares agiram de forma semelhante, diminuindo a contaminação do canal principal e extruindo a mesma quantidade de debris, com a mesma contaminação. A PUI aumentou a extrusão e a contaminação dos debris dentinários em comparação com a irrigação convencional. / The main of this study was to compare the volume of debris and apical bacterial extrusion during root canal preparation with the Prodesign R and Prodesign Logic instruments, with different calibers and presence of passive ultrasonic irrigation (PUI) or not, in teeth contaminated with Enterococcus faecalis (ATCC29212). Methods: 90 lower premolars were used, decoronated and standardized in 16 mm, divided into 8 groups (n = 10) according to the systems to be used; Prodesign Logic 25.06, 35.05, Prodesign R 25.06 and 35.05, and the type of irrigant activation, contaminated for 5 days. Extruded debris were collected in empty microtubes previously weighed 3 times, inserted in the inferior part of a metallic device for a later weighing of the debris. Samples of main root canals were also collected in addition of debris for a microbiological evaluation of colony forming units (CFU / mL). Results: The movement, rotational or reciprocating, and the diameter of the caliber, 25 or 35, showed no differences between them (P> 0.05). Comparing conventional irrigation with the use of ultrasound, the latter promoted a greater amount of debris extruded through the foramen (P <0.05). In the microbiological analysis of the debris collections, the Prodesign Logic 25 system promoted a greater amount of contaminated debris (P <0.05). I In the collections of the root canal both the conventional irrigation and the ultrasonic agitation showed a decrease of the CFU / mL from initial collections compared to the finals, with no statistical difference (P <0.05). Microbial contamination in the extruded debris was lower in the group where conventional irrigation was used (P <0.05). Conclusions: The instrument, caliber and the type of movement used in root canals acted similarly, reducing the contamination of the main root canal and extruding the same amount of debris, with the same contamination. PUI increased the extrusion and contamination of dentinal debris compared to conventional irrigation.
|
7 |
Eletrodeposição de revestimentos funcionais compósitos Cu/partículas de óxidos de alumínio / Electrodeposition of functional composite coatings Cu/partículas de óxidos de alumínioThaís Guimarães de Lima 14 March 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Revestimentos funcionais compósitos são um atrativo tecnológico crescente, pois possibilitam a combinação de materiais metálicos, poliméricos ou cerâmicos, resultando em propriedades superiores as dos materiais individuais, sendo por este motivo, largamente aplicados na engenharia de materiais. Na presente dissertação, foram produzidos revestimentos compósitos por eletrodeposição através da
codeposição de uma matriz metálica de cobre e de partículas de óxidos de alumínio incorporadas (g - Al2O3 ou AlO(OH)), sobre substratos de aço carbono, a partir de diferentes banhos eletrolíticos. Três etapas foram efetuadas, na primeira realizou-se o estudo da influência do modo de agitação e da presença ou não de ligantes (citrato de sódio 1,00 mol/L) nos teores de cobre e alumina nos revestimentos produzidos. Em seguida foi avaliada a ação de complexantes (citrato de sódio 1,00 mol/L e pirofosfato de potássio 0,90 mol/L) usando polarização potenciodinâmica e voltametria cíclica, em conjunto com microbalança eletroquímica de cristal de quartzo (EQCM) e a posterior produção de revestimentos compósitos a partir de banhos contendo CuSO4 0,02 mol/L + pirofosfato de potássio 0,90 mol/L + 20 g/L de alumina, variando a densidade de corrente aplicada (I), a velocidade de agitação do eletrodo rotatório (A) e o do tempo de agitação prévia (t). Por fim, na terceira etapa, fez-se a substituição de alumina por Boehmita e a produção dos revestimentos a partir de banhos contendo CuSO4 0,02 mol/L + pirofosfato de potássio 0,90 mol/L + 20 g/L de Boehmita, empregando um planejamento composto central, em que os parâmetros citados também foram variados. Os resultados mostraram que a presença de um ligante e a agitação prévia e continuada do eletrólito durante o experimento foram fundamentais para a produção dos revestimentos compósitos. Ensaios de EQCM mostraram que o citrato se adsorveu na superfície do eletrodo de ouro, diferentemente do pirofosfato. Os teores de Boehmita e cobre nos revestimentos produzidos, assim como a morfologia, resistência de polarização e densidade de corrente de corrosão dos revestimentos foram influenciados pelos parâmetros avaliados. / Functional coatings composites are an increasing technologic attractive, as they allow the combination of metallic, polymeric or ceramic materials resulting in properties superior than those of the individual materials. They are, therefore, widely used in engineering materials. In this dissertation, composite coatings were produced
by electrodeposition through co-deposition of a copper metal matrix and particulate aluminum oxides embedded (g - Al2O3 or AlO (OH)) on carbon steel substrates from different electrolytic baths. Three steps were taken: first the influence of the stirring mode and the presence or absence of ligands (sodium citrate 1.00 mol/L) in the amount of copper and alumina in the produced coatings were studied. After it, was evaluated the action of complexing agents (Sodium citrate 1.00 mol/L and potassium pyrophosphate 0.90 mol/L) using potentiodynamic polarization and cyclic voltammetry together with electrochemical microbalance quartz crystal (EQCM), and
further producing composite coatings from baths containing CuSO4 0.02 mol/L potassium pyrophosphate + 0.90 mol/L + 20 g/L of alumina, varying the applied current density (I), the stirring speed of the rotating electrode (A) and the stirring time prior to electrodeposition (t). Finally in the last step was performed the substitution of alumina by bohemite and production of coatings from baths containing CuSO4 0.02 mol/L potassium pyrophosphate + 0.90 mol/L + 20 g/L bohemite, employing a central composite design, in which these parameters were also varied. The results showed
that the presence of a ligand and the electrolyte stirring prior and during the experiment were critical to the production of composite coatings. EQCM tests showed that the citrate is adsorbed on the surface of the gold electrode, unlike pyrophosphate. The results showed that the contents of boehmite and copper in the coatings produced, as well as the morphology, polarization resistance and corrosion current density of the coatings were influenced by the evaluated parameters
|
8 |
Comparison of mechanical behavior between conventional NiTi, CM, M-Wire and CM-EDM alloy instruments for cyclic fatigue and torsion fracture - evaluation of fracture surface in scanning electron microscope / Comparação do comportamento mecânico entre instrumentos de liga NiTi convencional, CM, M-Wire e CM-EDM quanto a fratura por fadiga cíclica e por torção avaliação da superfície da fratura em microscópio eletrônico de varreduraRenan Diego Furlan 31 July 2018 (has links)
The aim of this study was to evaluate the cyclic and torsional fatigue resistance of Nickel-Titanium rotary instruments manufactured by different thermal treatments. Were tested a total of 140 rotary instruments (n=20): Genius (GN size 25, .04 taper), Trushape (TS size 25, .06 taper), Logic (LOG size 25, .06 taper), Vortex Blue (VB size 25, .06 taper), ProTaper Gold (PTG size 25, .08 taper), Hyflex CM (HCM size 25, .06 taper) and Hyflex EDM (EDM size 25, .08 taper). Cyclic fatigue resistance testing was performed using an artificial stainless steel canal with a curvature (60° angle and 5- mm radius) located at 5 mm from the tip. The files (n=10) rotated until fracture and time was recorded in seconds. The torsional test evaluated the angular deflection and torque at failure of the instruments (n=10) at 3 mm from the tip according to ISO 3630- 1. The fractured surface of five instruments of each brand was observed by using scanning electron microscopy (SEM). Data were analysed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. The cyclic fatigue resistance value of EDM size 25, .08 taper was significantly higher than those of all instruments tested (P<0.05). The LOG size 25, .06 taper showed a higher cyclic fatigue resistance than those of GN size 25, .04 taper; TS size 25, .06 taper (P<0.05). There was no difference among the others groups. The torsional test showed that PTG size 25, .08 taper had the highest torsional strength value of all instruments tested followed by VB size 25, .06 taper and EDM size 25, .06 taper (P<0.05). The LOG size 25, .06 taper showed significant difference only with GN size 25, .04 taper (P<0.05). No difference was found among the others groups (P>0.05). In relation to angular deflection, the GN size 25, .04 taper; TS size 25, .06 taper; HCM size 25, .06 taper, and EDM size 25, .08 taper showed significantly higher values until fracture than the others groups (P<0.05). No difference was found among PTG size 25, .08 taper, LOG size 25, .06 taper, and VB size 25, .06 taper (P<0.05). The EDM size 25, .08 taper presented the highest cyclic fatigue resistance among all the tested instruments. For the torsional test, the PTG size 25, .08 taper showed highest torsional strength and lowest angular deflection values. / O objetivo deste estudo foi avaliar a resistência às fadigas cíclica e torsional de instrumentos rotatórios de Níquel - Titânio fabricados por diferentes tratamentos térmicos. Foram testados o total de 140 instrumentos (n=20): Genius (GN diâmetro 25, conicidade .04), Trushape (TS diâmetro 25, conicidade .06), Logic (LOG diâmetro 25, conicidade .06), Vortex Blue (VB diâmetro 25, conicidade .06), ProTaper Gold (PTG diâmetro 25, conicidade .08), Hyflex CM (HCM diâmetro 25, conicidade .06) e Hyflex EDM (EDM diâmetro 25, conicidade .08). O teste de resistência à fadiga cíclica foi realizado utilizando um canal artificial de aço inoxidável com curvatura (ângulo de 60° e raio de 5mm) localizada a 5 mm da ponta. Os instrumentos (n=10) foram rotacionados até a fratura e tempo foi registrado em segundos. O teste torsional avaliou a deflexão angular e torque até a falha dos instrumentos (n=10) a 3 mm da ponta de acordo com a ISO 3630-1. A superfície da fratura de 5 instrumentos de cada fabricante foi observado utilizando o microscópio eletrônico de varredura (MEV). A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. O valor de resistência a fadiga cíclica do EDM diâmetro 25, conicidade .08 foi significantemente maior que todos os instrumentos testados (P<0.05). A LOG diâmetro 25, conicidade .06 mostrou maior resistência à fadiga cíclica que o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06 (P<0.05). Não houve diferença significante entre os outros grupos. O teste torsional mostrou que PTG diâmetro 25, conicidade .08 obteve o maior valor de torque até a fratura de todos os instrumentos testados seguido por VB diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .06 (P<0.05). O LOG diâmetro 25, conicidade .06 mostrou diferença significativa apenas com com GN diâmetro 25, conicidade .04 (P<0.05). Não houve diferença significativa entre os outros grupos (P>0.05). Em relação a deflexão angula, o GN diâmetro 25, conicidade .04; TS diâmetro 25, conicidade .06; HCM diâmetro 25, conicidade .06 e EDM diâmetro 25, conicidade .08 apresentou significantimente o maior valor até a fratura que os outros grupos (P<0.05). Nao foi encontrado diferença significativa entre PTG diâmetro 25, conicidade .08, LOG diâmetro 25, conicidade .06, e VB diâmetro 25, conicidade .06 (P<0.05). O EDM diâmetro 25, conicidade .08 apresentou a maior resistência a fadiga cíclica entre todos os instrumentos testados. Para o teste torsional, o PTG diâmetro 25, conicidade .08 apresentou o maior valor de torque e menor deflexão angular.
|
9 |
Estudo Mecanístico da Eletrodeposição de Cádmio em Meio de Sulfato Ácido / Mechanistical study of cadmium electrodeposition in acidic sulphate mediumCampos, Othon Souto January 2011 (has links)
CAMPOS, Othon Souto. Estudo Mecanístico da Eletrodeposição de Cádmio em Meio de Sulfato Ácido. 2011. 46 f. Dissertação (Mestrado em química)- Universidade Federal do Ceará, Fortaleza-CE, 2011. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-02T19:41:14Z
No. of bitstreams: 1
2011_dis_oscampos.pdf: 938891 bytes, checksum: 170c80aaa846defc16b0b360c53792fb (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-20T20:01:55Z (GMT) No. of bitstreams: 1
2011_dis_oscampos.pdf: 938891 bytes, checksum: 170c80aaa846defc16b0b360c53792fb (MD5) / Made available in DSpace on 2016-07-20T20:01:55Z (GMT). No. of bitstreams: 1
2011_dis_oscampos.pdf: 938891 bytes, checksum: 170c80aaa846defc16b0b360c53792fb (MD5)
Previous issue date: 2011 / This work describes a mechanistical proposition for cadmium electrodeposition in acid sulfate medium on platinum substrate using electrochemical techniques. The cadmium electrodeposition studies were carried in sodium sulfate 1 mol L–1 medium containing cadmium sulfate 10–2 mol L–1, which the pH of the solutions were adjusted with analytical grade sulfuric acid. The pH interval of the work solutions were ranged between 1 and 3. In all studied medium, the potentiostatic polarization curves showed a diffusional plateau which obeys the Levich equation. The interfacial pH studies showed the influence of acid–base equilibrium of bisulfate ion with the formation of a coordination compound Cd(HSO4)+ in platinum electrode. It is proposed that the cadmium ion associated in acid–base equilibrium of bisulfate ion, deposits as cadmium bisulfate at an irreversible step, and followed by a reversible metallic deposition of cadmium with the leaving of bisulfate ion, and this step is slower than the first one. Then, a mathematical model was calculated for the mechanism proposed, and qualitative studies were carried regarding to the polarization curve and electrochemical impedance spectroscopy behavior. / Este trabalho descreve uma proposição mecanística para a deposição de cádmio em meio de sulfato ácido sobre substrato de platina utilizando técnicas eletroquímicas. Os estudos de eletrodeposição de cádmio foram feitas em meio de sulfato de sódio 1 mol L–1 contendo 10–2 mol L–1 de sulfato de cádmio, em que o pH das soluções foi ajustado com ácido sulfúrico PA. O intervalo de pH das soluções de trabalho foi variado entre 1 e 3. Em todos os meios estudados, as curvas de polarização potenciostática mostraram a formação de um patamar difusional que obedece a equação de Levich. Os estudos de pH local revelaram a influência do equilíbrio ácido–base do íon bissulfato com formação de compostos de coordenação Cd(HSO4)+ no eletrodo de platina. Propõe-se que o íon cádmio, associado ao equilíbrio ácido–base do íon bissulfato, deposita como bissulfato de cádmio numa etapa irreversível, e seguida pela deposição de cádmio metálico reversível com a saída do íon bissulfato, sendo esta última etapa mais lenta que a primeira. Desse modo, foi calculado um modelo matemático para o mecanismo proposto, sendo realizados estudos qualitativos em relação ao comportamento da curva de polarização e do espectro de impedância eletroquímica.
|
10 |
Avaliação da extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único comparados a um sistema rotatório multi-instrumento / Apical extrusion of bacteria by reciprocating single file systems and rotary multi-file systemJustine Monteiro Monnerat Tinoco 27 September 2013 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação mecanizada com sistemas reciprocantes de instrumento único e movimento reciprocante (WaveOne and Reciproc) comparados a um sistema multi-instrumentos (BioRaCe). Quarenta e cinco incisivos inferiores humanos unirradiculares, ovais e de anatomia semelhante foram utilizados. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em três grupos com 15 espécimes cada (RE - Reciproc, WO -WaveOne e BR - BioRaCe). Foram utilizados oito dentes para grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas dos frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelos testes estatísticos de Wilcoxon e Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os dois sistemas reciprocantes (p>0,05). Em contrapartida, o sistema de instrumentos rotatórios mostrou uma quantidade de UFC significativamente maior do que os dois outros grupos (p <0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que todos os sistemas de instrumentação testados extruem bactérias apicalmente. No entanto, ambos os sistemas de instrumento único e movimento reciprocante extruem menos bactérias apicalmente do que o sistema rotatório multi-instrumentos de referência. / The aim of this work was to evaluate ex vivo the apical bacterial extrusion of reciprocating single-file systems (Wave One and Reciproc) compared to a multi-file rotary system (BioRaCe). This was tested in the current study using extracted, single-rooted teeth with oval canals (n = 45) with similar anatomy. Endodontic access cavities were prepared and root canals were contaminated with an Enterococcus faecalis suspension and incubated for thirty days to promote bacterial biofilm growth. The contaminated teeth were divided into three groups with 15 specimens each (RE - Reciproc, WO- Wave One and BR - BioRaCe). Positive and negative bacterial growth control groups were done. Bacterial extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in BHI agar medium during 24h. Bacterial growth was counted and the results were given by colony-forming units (CFU). These data were analyzed by Wilcoxon matched-pairs signed rank test and KruskalWallis H-test. After data analysis, no significant difference was found in the number of CFU between the two reciprocating systems (p > 0.05). Conventional multi-file rotary system group showed significantly higher CFU than both of the other two reciprocating groups (p<0.05). Based on the results evaluation and within the limitation of this study, it was possible to conclude that all tested instrumentation systems extruded bacteria beyond the apex. However, both reciprocation single-file systems apically extruded fewer bacteria than the conventional multi-file rotary system.
|
Page generated in 0.0584 seconds