• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A SPECTROSCOPIC INVESTIGATION OF A SURFACE-DISCHARGE-MODE, DIELECTRIC BARRIER DISCHARGE

Stanfield, Scott Alan, II 30 December 2009 (has links)
No description available.
2

Studium procesů v dohasínajícím plazmatu / Study of Post-Discharge Processes

Soural, Ivo January 2011 (has links)
The decaying plasma was studied by the optical emission spectroscopy. DC discharge created at 45 – 200 mA in Pyrex and Quartz tubes in flowing regime was used. The emission of three nitrogen spectral systems (1st and 2nd positive and 1st negative) were studied in time evolution for pressures of 500 – 5 000 Pa at two wall temperatures – ambient and liquid nitrogen (150 K inside the decaying plasma). Results showed that all three nitrogen systems (respectively N2(B, v), N2(C, v) and N2+(B, v) states as their origins) had their population maxima called pink-afterglow in the afterglow part. These maxima decreased with the increase of pressure for all systems, and moved to the later decay time. Maxima increased with discharge current (respectively power) and moved to shorter time. Populations at temperature of 150 K were measured due to the experimental arrangement from 17 ms, only, and thus pink aftergow maximum wasn’t observed (only at 5 000 Pa some maximum was recognized). Populations were smaller at 150 K that populations measured at laboratory temperature at the middle decay time (50-100 ms). At the late time, the populations were higher at lower temperature at lower pressure. Higher shifts (in intensity and decaytime) of pink afterglow maxima were observed in Quartz tube in comparison with their values in Pyrex tube. Besides the populations, rotational temperatures of selected bands of three observed spetral systems (for 1st negative 0-0 band, 1st positive 2-0 band and for 2nd positive 0-2 band) were measured. Rotational temperatures were monitored from presumption that this kind of temperature is equal to temperature of neutral gas (at local thermodynamic equilibrium). Results from 1st negative and 1st positive system showed strong decreasing of rotational temperatures up to about 10 ms at post-discharge begin, then temperatures were constant up to 20 ms of decay time and after that they grew up. Temperatures increased with the increase of current. The part with decreased temperature correlated with pink-afterglow part of post-discharge. Unfortunately, rotational temperatures of 2nd positive system had bad reproducibility and the time profile shape was opposite. Experimental results were compared with numerical kinetic model created by group of prof. Vasco Guerra at Instituto Supetior Técnico in Portugal. Several sets of conditions for simulation at 500 and 1 000 K in active discharge were applicable for the calculation corresponding to the experiment. Comparison of numerical simulation and experimental data done for N2(B) state demonstrated that maxima populations in pink afterglow are depended on the temperature difference between active discharge and post discharge. Maxima populations were supposed in pink afterglow disappeared if the same temperatures in active and post discharges were supposed. Temperature in active discharge is higher at higher apllied power, as it was showed from rotational temperatures observation. The results clearly showed that real temperature profile must be included into the kinetic model.
3

Diagnostika plazmatu výboje ve vodných roztocích a jeho aplikace / Diagnostics of plasma generated in water solutions and its application

Holíková, Lenka January 2011 (has links)
This thesis deals with the study of parameters of diaphragm discharge in liquids. NaCl solution of different conductivity was used as a conductive medium. Conductivities were adjusted in the range from 220 to 1000 µS cm-1. Two diagnostic methods were used for the study of plasma parameters. The first one was employed in the laboratory of plasma chemistry at Faculty of Chemistry, Brno University of Technology, namely the optical emission spectroscopy. The second method used for plasma diagnostics was the time resolved ICCD camera at the Laboratoire de Physique des Plasmas at the École Polytechnique in Paris. The reactor for the diagnostics by optical emission spectroscopy had the volume of 4 l, and it was made of polycarbonate. PET diaphragm was placed in the barrier separating the cathode and the anode space. Electrodes were made of titanium coated with platinum. Electric power source supplied a constant DC voltage of maximum 5 kV and electric current up to 300 mA. Spectrometer Jobin Yvon TRIAX 550 with CCD detector was used during the experiments in order to measure overview spectra within the range from 200 to 900 nm as well as OH molecular spectra and Hß line spectra. All spectra were scanned in both discharge polarities, i.e. at the cathode and the anode part of reactor. The basic parameters of the discharge plasma were calculated from the spectra, that means rotational and electron temperature and electron density. Another part of experiment consisted of measurements by the ICCD camera iStar 734. Two types of reactors were used. The first one was the same as the reactor for the measurements by the optical emission spectroscopy. The second one was also made of polycarbonate, but the volume of conductive solution was 110 ml, only. HV electrodes made of stainless steel were placed in this reactor. Ceramic diaphragm (Shapal-MTM) was used in both reactors. Diaphragms had different thickness and diameter of holes. ICCD camera acquired photographs with details of processes of the bubbles generation and discharge operation (propagation of plasma channels), depending on solution conductivity, dimensions of the diaphragm, and with respect to the electrode part of the reactor.
4

Analyse de la température du gaz dans les plasmas de haute fréquence à la pression atmosphérique par spectroscopie à très haute résolution spectrale

Labelle, Francis 08 1900 (has links)
Le présent mémoire de maîtrise est consacré à une étude spectroscopique de la température du gaz dans les plasmas hors équilibre thermodynamique d’argon à la pression atmosphérique. Nous avons notamment pu extraire, à l’aide de mesures par spectroscopie optique d’émission de structures rotationnelles des systèmes OH (A2Σ+- X2Πi) et N2+ (B2Σu+- X2Σg+), la température rotationnelle d’un plasma radiofréquence en régime capacitif et d’un plasma micro-onde produit par une onde électromagnétique de surface. En comparant ces mesures à celles obtenues par l’analyse de l’élargissement des raies 2p2-1s2 et 2p3-1s2 de l’argon avec un spectromètre à très haute résolution spectrale, nous avons pu démontrer que l’équilibre rotation-translation (Trot=Tg) n’est jamais atteint dans les configurations de plasmas étudiées. Cet écart entre les deux températures est attribué à l’influence des électrons, en compétition avec les atomes neutres, imposant leurs propres températures sur la distribution des niveaux rotationnels. De plus, l’effet du flux de gaz et de l’ajout de CO2 sur le chauffage du gaz a été étudié dans un plasma micro-onde d’argon à la pression atmosphérique. Nous avons noté des changements importants dans les profils axiaux de Tg en amont et en aval de l’excitateur à onde de surface selon les conditions opératoires. Pour séparer les facteurs gouvernant le chauffage du gaz à ceux associés au dépôt de puissance par l’onde électromagnétique, nous avons normalisé nos valeurs de Tg aux intensités des émissions de l’argon liées aux transitions 2p-1s entre 700 et 900 nm. Pour des temps de résidence dans le plasma d’argon suffisamment longs (et donc de faibles débits de gaz), les valeurs de Tg normalisées montrent un comportement assez constant, ce qui indique que le chauffage s’effectue principalement de manière locale. Au contraire, pour des temps plus longs (et donc des débits de gaz plus importants), les valeurs de Tg normalisées augmentent le long de la colonne à plasma, ce qui révèle que les phénomènes de transport commencent à jouer un rôle important. On note aussi un changement de comportement à plus hauts débits de gaz dû au passage d’un régime d’écoulement laminaire à un régime turbulent. En présence de CO2, dû aux mécanismes de chauffage additionnels, les valeurs de Tg normalisées sont systématiquement plus élevées. / The present master thesis is devoted to a spectroscopic study of the gas temperature in non-thermodynamic equilibrium argon plasmas at atmospheric pressure. In particular, we were able to extract, by means of optical emission spectroscopy measurements of rotational structures of the systems OH (A2Σ+- X2Πi) and N2+ (B2Σu+- X2Σg+), the rotational temperature of a radiofrequency plasma in capacitive mode and of a microwave plasma produced by an electromagnetic surface wave. By comparing these measurements with those obtained by the analysis of line broadening from 2p2-1s2 et 2p3-1s2 of argon with an ultrahigh spectral resolution spectrometer, we were able to demonstrate that the rotational-translational equilibrium (Trot=Tg) is never achieved in the plasma configurations studied. The departure from both temperatures is ascribed to the influence of electrons competing with neutrals to impose their own temperature on the distribution of rotational levels. In addition, the effect of gas flow and addition of CO2 admixtures on the gas heating has been studied in a microwave argon plasma at atmospheric pressure. We noted significant changes in the axial profiles of Tg on the upstream and downstream plasma column according to operating conditions. To separate the factors governing the heating of gas from those associated with the deposition of power by the electromagnetic wave, we have normalized our Tg values to the intensities of the argon emissions linked to the transitions 2p-1s between 700 and 900 nm. For long enough gas residence times in the argon plasma (and therefore low gas flow rates), normalized Tg values show a fairly constant behaviour, which indicates that the heating takes place mainly locally. On the contrary, for longer times (and therefore higher gas flow rates), normalized Tg values increases along the plasma column, which reveals that transport phenomena are starting to play an important role. There is also a change in behaviour at higher gas flow rates due to the change from a laminar flow regime to a turbulent regime. In the presence of CO2 admixtures, due to additional heating mechanisms, normalized Tg values are consistently higher.
5

Analyse physico-chimique de milieux liquides d’intérêt biologique exposés à des plasmas froids produits à pression atmosphérique et température ambiante / Physico-chemical analysis of liquid media of biological interest exposed to cold plasmas produced at atmospheric pressure and room temperature

Girard, Fanny 05 December 2017 (has links)
Les plasmas froids sont des gaz partiellement ionisés, très riches d’un point de vue physico-chimique. Cette propriété se retrouve dans des plasmas froids aujourd’hui générés à pression atmosphérique et température ambiante et a été mise à profit depuis une quinzaine d’années environ pour des applications biomédicales (hématologie, dermatologie, cancérologie, odontologie etc…). L’efficacité de ces plasmas froids dans le domaine de la médecine a été prouvée par de nombreuses études. Cependant, les phénomènes biologiques mis en jeu ne sont pas encore bien compris, et il primordial de savoir quels pourraient être les éventuels effets secondaires indésirables de ces milieux ionisés réactifs. Le premier niveau d’interaction des plasmas avec le vivant est celui avec les milieux liquides, qui sont présents en surface des tissus, des cellules in vivo ou en culture. Depuis une décennie, une attention particulière a donc été portée aux interactions des plasmas avec les liquides, pour apporter un niveau de compréhension supplémentaire. La compréhension de ces interactions a constitué l’axe de ce travail. Différents réacteurs à plasmas froids (générés à pression atmosphérique et température ambiante) ont été développés, notamment afin de contrôler les interactions du plasma avec l’air ambiant qui peuvent être problématiques pour les applications visées. La nature du gaz servant à initier le plasma a été modifiée, pour connaître son influence sur la réactivité chimique de la phase gaz. Pour cela, des mesures de spectroscopie d’émission optique (SEO) ont été nécessaires. Par ailleurs, de nouveaux capteurs électrochimiques et des approches méthodologiques ont été développés pour identifier et quantifier les espèces réactives de l’oxygène et de l’azote (RONS) produites dans des milieux liquides physiologiques, exposés à ces gaz ionisés. Les analyses électrochimiques ont été combinées à de la spectroscopie d’absorption UV-visible ainsi qu’à d’autres méthodes de chimie (pH-métrie/conductimétrie). Un des objectifs visés est d’établir une corrélation entre les espèces réactives générées dans la phase gaz et dans la phase liquide. Enfin, des expérimentations nous ont permis d’analyser la production des RONS dans des liquides in situ en temps réel. Les mesures de SEO montrent qu’il existe de nombreuses espèces chimiques excitées au sein des différents plasmas (NO°, HO°, O, N2+ (FNS) etc…). Les analyses de la phase liquide ont révélé la présence d’espèces stables de l’oxygène et de l’azote (H2O2, NO2-, NO3-), directement reliées aux espèces détectées dans les plasmas. De plus, les diverses méthodologies d’analyse chimique mises en place ont permis la détection et la quantification de RONS tels que l’anion peroxynitrite ONOO-. L’ensemble des résultats obtenus devrait permettre d’appréhender de façon plus fine les effets induits par différents plasmas froids dans des milieux liquides physiologiques afin d’établir un lien avec les études menées sur des cellules en culture et sur la peau dans le cadre d’un programme de recherche financé par l’ANR, Agence Nationale de la recherche. / Cold plasmas are partially ionized gases, very rich in a physico-chemical point of view. This property characterizes cold plasmas today generated at atmospheric pressure and ambient temperature and was used since about fifteen years approximately for biomedical applications (haematology, dermatology, cancer research, odontology etc.). The efficiency of these cold plasmas in the field of the medicine was proved by numerous studies. However, the involved biological phenomena are not still well included, and it is essential to know what could be the possible unwanted side effects of these reactive ionized gases. The first level of interaction of plasmas with living matter is the one with the liquid phase, which is present on the tissue surface, in vivo cells or in culture. For a decade, a particular attention was thus worn in the interactions of plasmas with liquids, to bring a level of additional understanding. The understanding of these interactions constituted the axis of this work. Various cold plasmas reactors (generated at atmospheric pressure and ambient temperature) were developed, in order to control the interactions of these plasmas with the ambient air which can be problematic for the aimed applications. The nature of the gas used to initiate the plasma was modified, to know its influence on the chemical reactivity of the gas phase. For that purpose, measurements of optical emissive spectroscopy (OES) were necessary. Besides, new electrochemical sensors and methodological approaches were developed in order to identify and quantify the reactive nitrogen and oxygen (RONS) produced in physiological liquid media, exposed to these ionized gases. The electrochemical analyses were combined UV-visible absorption spectroscopy as well as other methods of chemistry (pH-metry/conductimetry). One of the aimed objectives is to establish a correlation between the reactive species generated in the gas phase and in the liquid phase. Finally, experiments allowed us to analyze the production of RONS in liquids in situ and in real time. OES measurements showed that there are numerous chemical species generated in various plasmas (NO°, HO°, O, N2+ (FNS) etc.). The analyses of the liquid phase revealed the presence of stable oxygen and nitrogen species (H2O2, NO2-, NO3-), directly correlated with the species detected in plasmas. Furthermore, the diverse methodologies of chemical analysis allowed the detection and quantification of RONS such as the peroxynitrite anion ONOO-. The obtained results should allow to arrest in a finer way the effects led by various cold plasmas in physiological liquid media to establish links with the studies led on cultured cells and on skin within the framework of a research program financed by the ANR, National Agency of the Research.
6

Vergleich dielektrisch behinderter Entladungen bezüglich der physikalischen Eigenschaften und der Wirkung auf Holz und Holzwerkstoffe / Comparison of dielectric barrier discharges regarding their physical properties and the influence on wood and wooden materials

Peters, Frauke 22 October 2018 (has links)
No description available.
7

Étude expérimentale de micro-plasmas froids à la pression atmosphérique générés par des hautes tensions de formes différentes / Experimental study of atmospheric pressure cold micro-plasmas generated by high voltages of different waveforms

Gazeli, Kristaq 26 October 2015 (has links)
Cette thèse porte sur l'étude de micro-plasmas froids à la pression atmosphérique générés à partir de différents réacteurs des configurations basées sur le principe des Décharges à Barrière Diélectrique (DBD) et alimentés par des générateurs de tension impulsionnelle et sinusoïdale. Les plasmas sont formés dans des gaz nobles tels que l'hélium et l'argon (gaz vecteurs), et également dans des mélanges réalisés avec des gaz moléculaires tels que l'azote et l'oxygène afin de produire des Espèces Réactives de l’Azote et de l’Oxygène (ERA, ERO). La (ré)activité chimique du plasma est ainsi supposée être accrue, permettant le traitement de matériaux inertes ou vivants pour diverses applications (fonctionnalisation de surfaces, inactivation de cellules, régénération de tissus vivants, etc.). La caractérisation des plasmas étudiés est réalisée en enregistrant les aspects électriques et optiques en fonction des paramètres élémentaires, comme l’amplitude et la fréquence de la tension, le débit du gaz, la configuration des électrodes, et le rapport cyclique dans le cas du régime pulsé. Ainsi, la (ré)activité chimique des plasmas est évaluée tandis que au même temps les mécanismes de la génération des plasmas et les façons de l’optimisation de la chimie sont dévoilées. Finalement, nous examinons l'efficacité du plasma dans le domaine biomédical en traitant divers systèmes biologiques (bactéries, liposomes, cellules) sans effets thermiques. / The present PhD thesis is devoted to the study of atmospheric pressure cold micro-plasmas produced in different Dielectric Barrier Discharge (DBD) reactors which are driven by pulsed or sinusoidal high voltages. Noble gases such as helium and argon are used as carrier gases, whereas admixtures with nitrogen and oxygen are studied as well. The formation of Reactive Nitrogen and Oxygen Species (RNS, ROS) is thus achieved, and the possibility of improving the chemical (re)activity of the plasmas is demonstrated. This is of interest in the treatment of inert or living materials (e.g. surface functionalization, cell inactivation, living tissue regeneration, etc.). Plasmas are characterized by recording electrical and optical features as a function of principal operational parameters, including voltage amplitude and frequency, gas flow rate, electrode configuration, and voltage duty cycle in the case of pulsed waveform. The physico-chemical (re)activity of the plasmas is thus evaluated, while at the same time mechanisms on the plasma generation and paths for chemistry optimization are unveiled. Finally, the efficiency of the plasma in relation to biomedical applications is tested by treating different biological systems (bacteria, liposomes, cells) while preventing any thermal effect.

Page generated in 0.5309 seconds