• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 6
  • 3
  • Tagged with
  • 25
  • 17
  • 15
  • 13
  • 13
  • 13
  • 8
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

A 16-Channel Fully Configurable Neural SoC With 1.52 μW/Ch Signal Acquisition, 2.79 μW/Ch Real-Time Spike Classifier, and 1.79 TOPS/W Deep Neural Network Accelerator in 22 nm FDSOI

Zeinolabedin, Seyed Mohammad Ali, Schüffny, Franz Marcus, George, Richard, Kelber, Florian, Bauer, Heiner, Scholze, Stefan, Hänzsche, Stefan, Stolba, Marco, Dixius, Andreas, Ellguth, Georg, Walter, Dennis, Höppner, Sebastian, Mayr, Christian 21 February 2024 (has links)
With the advent of high-density micro-electrodes arrays, developing neural probes satisfying the real-time and stringent power-efficiency requirements becomes more challenging. A smart neural probe is an essential device in future neuroscientific research and medical applications. To realize such devices, we present a 22 nm FDSOI SoC with complex on-chip real-time data processing and training for neural signal analysis. It consists of a digitally-assisted 16-channel analog front-end with 1.52 μ W/Ch, dedicated bio-processing accelerators for spike detection and classification with 2.79 μ W/Ch, and a 125 MHz RISC-V CPU, utilizing adaptive body biasing at 0.5 V with a supporting 1.79 TOPS/W MAC array. The proposed SoC shows a proof-of-concept of how to realize a high-level integration of various on-chip accelerators to satisfy the neural probe requirements for modern applications.
22

Multifunctional Droplet-based Micro-magnetofluidic Devices

Lin, Gungun 23 August 2016 (has links) (PDF)
Confronted with the global demographic changes and the increasing pressure on modern healthcare system, there has been a surge of developing new technology platforms in the past decades. Droplet microfluidics is a prominent example of such technology platforms, which offers an efficient format for massively parallelized screening of a large number of samples and holds great promise to boost the throughput and reduce the costs of modern biomedical activities. Despite recent achievements, the realization of a compact and generic screening system which is suited for resource-limited settings and point-of-care applications remains elusive. To address the above challenges, the dissertation focuses on the development of a compact multifunctional droplet micro-magnetofluidic system by exploring the advantages of magnetic in-flow detection principles. The methodologies behind a novel technique for biomedical applications, namely, magnetic in-flow cytometry have been put forth, which encompass magnetic indexing schemes, quantitative multiparametric analytics and magnetically-activated sorting. A magnetic indexing scheme is introduced and intrinsic to the magnetofluidic system. Two parameters characteristic of the magnetic signal when detecting magnetically functionalized objects, i.e. signal amplitude and peak width, providing information which is necessary to perform quantitative analysis in the spirit of optical cytometry has been proposed and realized. Magnetically-activated sorting is demonstrated to actively select individual droplets or to purify a population of droplets of interest. Together with the magnetic indexing scheme and multiparametric analytic technique, this functionality synergistically enables controlled synthesis, quality administration and screening of encoded magnetic microcarriers, which is crucial for the practical realization of magnetic suspension arrays technologies. Furthermore, to satisfy the needs of cost-efficient fabrication and high-volume delivery, an approach to fabricate magnetofluidic devices on flexible foils is demonstrated. The resultant device retains high performance of its rigid counterpart and exhibits excellent mechanical properties, which promises long-term stability in practical applications.
23

A 16-Channel Fully Configurable Neural SoC With 1.52 μW/Ch Signal Acquisition, 2.79 μW/Ch Real-Time Spike Classifier, and 1.79 TOPS/W Deep Neural Network Accelerator in 22 nm FDSOI

Zeinolabedin, Seyed Mohammad Ali, Schüffny, Franz Marcus, George, Richard, Kelber, Florian, Bauer, Heiner, Scholze, Stefan, Hänzsche, Stefan, Stolba, Marco, Dixius, Andreas, Ellguth, Georg, Walter, Dennis, Höppner, Sebastian, Mayr, Christian 20 January 2023 (has links)
With the advent of high-density micro-electrodes arrays, developing neural probes satisfying the real-time and stringent power-efficiency requirements becomes more challenging. A smart neural probe is an essential device in future neuroscientific research and medical applications. To realize such devices, we present a 22 nm FDSOI SoC with complex on-chip real-time data processing and training for neural signal analysis. It consists of a digitally-assisted 16-channel analog front-end with 1.52 μ W/Ch, dedicated bio-processing accelerators for spike detection and classification with 2.79 μ W/Ch, and a 125 MHz RISC-V CPU, utilizing adaptive body biasing at 0.5 V with a supporting 1.79 TOPS/W MAC array. The proposed SoC shows a proof-of-concept of how to realize a high-level integration of various on-chip accelerators to satisfy the neural probe requirements for modern applications.
24

Veranschaulichung subzellulärer physikalischer Kräfte biochemischen und mechanischen Ursprungs mittels FRET / Insights into the spatiotemporal regulation of the cellular cytoskeleton through applications of FRET

Mitkovski, Miso 03 November 2005 (has links)
No description available.
25

Multifunctional Droplet-based Micro-magnetofluidic Devices

Lin, Gungun 16 August 2016 (has links)
Confronted with the global demographic changes and the increasing pressure on modern healthcare system, there has been a surge of developing new technology platforms in the past decades. Droplet microfluidics is a prominent example of such technology platforms, which offers an efficient format for massively parallelized screening of a large number of samples and holds great promise to boost the throughput and reduce the costs of modern biomedical activities. Despite recent achievements, the realization of a compact and generic screening system which is suited for resource-limited settings and point-of-care applications remains elusive. To address the above challenges, the dissertation focuses on the development of a compact multifunctional droplet micro-magnetofluidic system by exploring the advantages of magnetic in-flow detection principles. The methodologies behind a novel technique for biomedical applications, namely, magnetic in-flow cytometry have been put forth, which encompass magnetic indexing schemes, quantitative multiparametric analytics and magnetically-activated sorting. A magnetic indexing scheme is introduced and intrinsic to the magnetofluidic system. Two parameters characteristic of the magnetic signal when detecting magnetically functionalized objects, i.e. signal amplitude and peak width, providing information which is necessary to perform quantitative analysis in the spirit of optical cytometry has been proposed and realized. Magnetically-activated sorting is demonstrated to actively select individual droplets or to purify a population of droplets of interest. Together with the magnetic indexing scheme and multiparametric analytic technique, this functionality synergistically enables controlled synthesis, quality administration and screening of encoded magnetic microcarriers, which is crucial for the practical realization of magnetic suspension arrays technologies. Furthermore, to satisfy the needs of cost-efficient fabrication and high-volume delivery, an approach to fabricate magnetofluidic devices on flexible foils is demonstrated. The resultant device retains high performance of its rigid counterpart and exhibits excellent mechanical properties, which promises long-term stability in practical applications.

Page generated in 0.1001 seconds