• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 2
  • Tagged with
  • 12
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lokal kompensering i Mellanspänningsnät

Bassam, Diraoui January 2017 (has links)
Vid byte av luftledningar mot jordkabel kommer kapacitiva felström-mar att genereras. De kapacitiva felströmmarna ökar med större kabel-area. Rapporten behandlar problematiken med för stora bidrag av kapacitiva jordfelströmmar och dess inverkan på hela elnätet. Arbetetsfrågeställningar kommer att behandla utlokaliserad kompen-sation, oselektiv reläskyddsfunktion och skillnaden mellan långa led-ningar och stora nät. Syftet med uppsatsen är att belysa behovet av att utlokalisera kompensationen, bestämma antal och täthet av spolar som minskar kapacitiva strömmar på Alnön, samt titta på skillnaderna mellan långa och många ledningar både på tätortens och också lands-bygdens nät. I teoridelen tas teorier om olika typer av jordfelsskydds funktioner upp, lokal kompensering och skillnader mellan korta och långa markkabelns nät. Projektet är utfört genom utforskning av de metoder som används för att begränsa dem genererade kapacitiva felströmmen vid användning av markkablar. I slutsatsen kommer jag fram till att för förbättring av ledningsskydds-funktion på landsbygden måste kapacitiva strömmar transporteras genom kabeln i kortare sträckor. Detta kommer att minska spänningsfal-let över kabelns resistans och reaktans, eller att fördela nätet till små fack.
2

Jordfelsdetektering i mellanspänningsnätet : Konsekvenser av kablifiering

Axelsson Paulsson, Felix January 2020 (has links)
Det omfattande vädersäkrandet och därmed nedgrävning av kabel i mellanspänningsnätet leder till förändrade nätegenskaper. Rapporten undersöker problematiken som uppstår för detektering av jordfel och vad man bör tänka på vid jordfelsinställningar i stora kabelnät. Det stora kapacitiva strömbidraget från kabel kontra luftledning medför ett större behov av utlokaliserad kompensering för att förhindra onödiga spänningsfall samt fasvridning av den kapacitiva strömmen i ledningarna. Fasvridningen av den kapacitiva strömmen i ledningarna ger upphov till ytterligare aktiva strömkomponenter vilket försvårar hanteringen av jordfel. Felströmmen som uppkommer vid ett jordfel får inte vara för stor för att möta kraven om spänningssättning av utsatt del. I ett stort kabelnät kan inte längre serieimpedansen i nollföljd ignoreras, till skillnad från ett luftledningsnät, och kommer därför att ha en inverkan på den nollföljdsspänning som används för detektering av fel. Rapporten visar på hur nollföljdsspänningen inte är densamma i hela nätet, något som antas när man använder sig av den äldre beräkningsmodellen. Då man ställer in jordfelsskydden behöver man ta hänsyn till alla nätets komponenters nollföljdsstorheter så att man får en väl representerad nollföljdsimpedans, eftersom denna bestämmer storleken på nollföljdsspänningen och nollföljdsströmmen. De felaktiga antagandena riskerar att leda till felinställda jordfelsskydd varpå detektering av fel riskeras.
3

Projektering av allmänt lokalnät i landsbygdsmiljö med analys av kapacitivaströmmar

Solberg, Amanda, Ohrzén, Christoffer January 2019 (has links)
A general local powerline has implemented to mimic a lifelike powerline build around 1960s in thecountryside. Since reconstruction is needed a new projection is made of the area to improve the powerquality. The projection includes the old transmission lines will be replaced with underground powercables to make it weatherproof. The implication of underground power cables leads to smaller distancebetween the phases which generates greater capacitance. Due the increase will make the capacitivecurrents greater as well which affect the power quality for the costumers in the area. The projectionmust be adapted to the increase of earth fault currents which the capacitive currents contribute. The regeneration of the old and new power lines consists a sketch of terrain, merge of the powerconsumption, electrical fuses, line diagram, sizing transformers and right dimensions of cables. Calculations on capacitive fault current, voltage drop as well as neutral grounding reactor (a resistanceparallel with an inductor) was executed. Calculations of the powerline followed Swedish standard andthe neutral ground reactor after the norms of Swedish electrical industry. Regard to the projection, including underground cables, the capacitive fault currents increased with 46,75 times compared to transmission powerlines at 10 kV. Calculations of the neutral ground reactorresulted in 5,25 Henry for the inductor and 1154 Ohm for the resistor to compensate the gain. The conclusion is that weatherproofing the powerline at 10 kV leads to compensating otherwise the powerquality and selectivity will be affected. That result in a more expensive arrangement cost forunderground cables compared to transmission.
4

Analys av reläskyddsinställningar för jordfelsskydd

Edblom, Hampus January 2019 (has links)
Väl inställda reläskydd för ställverk är en nödvändighet för en personoch driftsäker anläggning. Rapportens mål är att undersöka om oriktade skydd med enbart signalering är tillräckligt för att skydda anläggningen som undersöks, och om riktade skydd har fördelen att förbättra felutpekning, minska risken för felaktig funktion eller minska funktionstiden. Anläggningen som undersökts är ett 6,3 kV industrinät med resistansjordning. I rapporten kontrolleras isolationsvärden och strömtoleranser för utrustningen, som sedan jämförs med beräknade spänningar och strömmar vid enfasiga jordfel. Rapporten beskriver också kort riktade skydd och dess funktioner i förhållande till frågeställningen om den eventuella fördelen med riktade skydd. Resultatet blev att överspänningar på grund av jordfel inte är något problem, men felströmmen genom nollpunktsmotståndet är för stor för enbart signalering. Vid stumma jordfel klarar nollpunktsmotståndet av att hantera felströmmen i 30 sekunder, varefter värmeutvecklingen resulterar i att nollpunktmotståndet kopplas bort och anläggningen blir isolerad från nollpunkten. Riktade skydd behövs enligt studien inte i en anläggning som denna. Detta är baserat på att kabelsträckorna är för korta för att orsaka kapacitiva strömmar tillräckligt stora för att felaktig funktion ska uppstå i oriktade skydd, och att nätstrukturen inte genererar strömmar i oväntade riktningar. Rapportens resultat visar att oriktade skydd är tillräckligt men att funktionen bör ställas om till bortkoppling av felande krets. / Well-adjusted relay protection for electrical substations is a necessity for personal safety and reliable operation. The aim of the report is to investigate whether non-directional protection with signaling alone is sufficient to protect the facility being investigated, and if directional protection has the advantage of improving fault detection, reducing the risk of unnecessary operation or reducing the function time. The facility under investigation is a 6.3 kV industrial network with resistance grounding. The report checks the insulation values and current tolerances for the equipment, which are then compared with calculated voltages and currents at single-phase earth faults. The report also briefly describes directional protection and its functions in relation to the issue of the potential benefit of directional protection. The result was that overvoltages due to earth faults are not a problem, but the fault current through the neutral point resistance is too large for signaling alone. In the case of earth faults with very low fault impedance, the neutral point resistance can handle the fault current for 30 seconds. After which the heat development results in the neutral point resistance being disconnected and the facility being isolated from the neutral point. According to the study, targeted protection is not needed in a facility like this. This is based on the fact that the cable paths are too short to cause capacitive currents large enough to cause unnecessary operation in non-directional protection, and that the network structure does not generate currents in unexpected directions. The result of the report shows that non-directional protection is sufficient, but that the operation function should be changed to tripping of faulty circuits
5

Användande av lokala nollpunktsreaktorer : Hantering av kapacitiva jordfelsströmmar i kabelnät / Using local neutral point reactors : Dealing with capacitive earth fault currents in cable grids

Magnusson, Johan January 2017 (has links)
The rural power grid has traditionally mostly consisted of overhead power lines. In recent years the trend has been to replace the overhead lines with cables instead. The reason is that overhead lines are relatively vulnerable, strong winds and storms can cause trees and branches to fall over the power lines and cause a phase to ground fault. This will then trip the ground fault relays and disconnect the faulty power line. A cable grid is not vulnerable in the same way, and could be considered a solution to make the power grid more reliable. A cable grid does come whit other types of problems instead. It generates about 50 times more phase to ground capacitance compared with the same length of overhead lines. When a phase to ground fault occurs the capacitance in the healthy phases will generate a current to ground and then through the fault. On average a cable grid generates about 2 A per kilometer. Large cable grids can therefore cause very large capacitive currents to flow through the fault.  To counter this, a reactor is placed between the neutral point of the transformer and ground. When a phase to ground fault occurs, the reactor will generate an inductive current which is in the opposite phase compared to the capacitive current. This current will flow through the faulty line and cancel out the capacitive current. In a perfectly tuned power grid the only component left in the fault is a smaller resistive current. Large cable grids will require a large reactor to generate the large inductive current, which might need to flow over a great distance in the grid to reach the fault location. To reduce the inductive current from the central reactor, it is possible to install smaller local reactors in the grid. These will then in the event of a phase to ground fault generate a part of the inductive current, which will reduce the currents from the central reactor. This report will look at the factors related to grounding systems and how these factors affect the ground fault currents. The purpose of the report is to give recommendations to Umeå Energi on where in their grid they should install additional local reactors and also which factors they should consider when doing future expansions and rebuilds of their power grid.
6

Manipulerade streams och dess roll i musikbranschen : - En kvalitativ studie om hur manipulerade streams färgar dagens musikbransch (ur ett marknadsföringsperspektiv). / Stream manipulations and its role in the music industry : - A qualitative study of how manipulated streams color today's music industry (from a marketing perspective).

Berggren, Alva, Danielsson, Samuel, Ogvall, Bernadina January 2021 (has links)
The digitalization and emergence of the Internet have given rise to new platforms providing marketing, distribution and revenues to happen in the same place, a significant difference from the past. New platforms have become new places for artists to compete for, for instance, positions on toplists. This is the fundamental background to the occurrence of manipulated streams in the music industry. The purpose of this study has been to examine and create a deeper understanding of manipulated streams and its role in the music industry, from a marketing perspective. Thus, the study aims to provide knowledge on the meaning of having high streaming numbers, why streams are being manipulated and how they are used in marketing.  The empirical data is based on six interviews with people from different parts of the music business. The results indicate that manipulated streams affect expectations of the artist and provide an opportunity for the artist to stand out in today's information overload. The artists have gained more power and influence as they are now being compared with influencers, and can influence the way the audience listens to music. Moreover, the findings also indicate that actors and platforms of the music industry need adjustments to encounter the phenomenon of manipulated streams.  Lastly, we suggest that future research should focus on how to prevent the occurrence of manipulated streams, in addition to social media's effect on cognitive behaviours of the users in relation to high streaming numbers.
7

Queryable Workflows: Extending Dataflow Streaming with Dynamic Request/Reply Communication / Arbetsflöden som kan efterfrågas: Utökning av dataflödesströmning med dynamisk begäran/återkopplingskommunikation

Huang, Chengyang January 2023 (has links)
Stream processing systems have been widely adopted in applications such as recommendation systems, anomaly detection, and system monitoring due to their real-time capabilities. Improving observability in stream processing systems can further expand their application scenarios, including the implementation of stateful serverless applications. Stateful serverless applications are an emerging model in serverless computing that focuses on addressing the challenges of state management, enabling developers to build distributed applications in a simpler way. One possible implementation of stateful serverless applications is based on stream processing engines. However, the current approaches for observability in stream processing engines suffer from issues such as efficiency, consistency, and functionality, resulting in limited practical use cases. To address these challenges, we propose Queryable Workflow, an extension to stream processing engines. This extension allows users to access or modify the state within stream processing engines with transactional semantics using a SQL interface, enabling use cases such as ad-hoc querying, serializable updates, or even stateful serverless applications. We implemented our system on stream processing engines such as Portals and Apache Flink, and evaluated their performance. The result showed that our system has achieved 4.33x throughput improvement and 30% latency reduction compared to a baseline implemented with Apache Flink and Apache Kafka. With hand-crafted optimizations, our system achieved to process over 29,000 queries per second with a 99th percentile latency of 8.58 ms under a single-threaded runtime. Our proposed system provides a viable option for implementing stateful serverless applications that require transactional guarantees, while also expanding the potential application scenarios for stream processing engines. / Strömbehandlingssystem har på grund av sina realtidsegenskaper fått stor spridning i tillämpningar som rekommendationssystem, anomalidetektering och systemövervakning. Förbättrad observerbarhet i stream processing-system kan ytterligare utöka deras tillämpningsscenarier, inklusive implementeringen av stateful serverless-applikationer. Stateful serverless-applikationer är en framväxande modell inom serverless computing som fokuserar på att hantera utmaningarna med tillståndshantering, vilket gör det möjligt för utvecklare att bygga distribuerade applikationer på ett enklare sätt. En möjlig implementering av stateful serverless-applikationer är baserad på stream processing-motorer. De nuvarande metoderna för observerbarhet i strömbehandlingsmotorer lider dock av problem som effektivitet, konsistens och funktionalitet, vilket resulterar i begränsade praktiska användningsfall. För att ta itu med dessa utmaningar föreslog vi Queryable Workflow, ett tillägg till stream processing-motorer. Med detta tillägg kan användare komma åt eller ändra tillståndet i strömbehandlingsmotorer med transaktionssemantik med hjälp av ett SQL-gränssnitt, vilket möjliggör användningsfall som ad hoc-förfrågningar, serialiserbara uppdateringar eller till och med serverlösa applikationer med tillstånd. Vi implementerade vårt system på stream processing-motorer som Portals och Apache Flink, och utvärderade deras prestanda. Resultatet visade att vårt system har förbättrat genomströmningen 4,33 gånger och minskat latensen med 30% jämfört med en baslinje som implementerats med Apache Flink och Apache Kafka. Med handgjorda optimeringar lyckades vårt system bearbeta över 29 000 frågor per sekund med en 99:e percentil latens på 8,58 ms under en enkeltrådad körtid. Vårt föreslagna system har gett ett hållbart alternativ för att implementera stateful serverless-applikationer som kräver transaktionsgarantier, samtidigt som det också utökat de potentiella applikationsscenarierna för stream processing-motorer.
8

Utredning av för- och nackdelar med TN-S respektive TN-C system / Investegation of the advantages and disadvantages of TN-S and TN-C systems

Alameddine, Raged, Dashtbozorg, Sajad January 2016 (has links)
I denna rapport analyseras för- och nackdelar med eldistributionssystem av typ TN-C (fyrledarsystem) respektive TN-S (femledarsystem) system. Det finns olika uppfattningar om vilket system som är lämpligast att bygga ut i distributionsnätet (lågspänningsnätet) och i fastigheternas huvudledning. Med hjälp av litteraturstudier och kontakt med olika elföretag och elbolag har olika ståndpunkter diskuterats och därefter har en sammanställning av resultatet tagits fram. Enligt analysen är TN-C det lämpligaste alternativet att använda i distributionsnätet och TN-S bör användas i fastighetens huvudledning. Detta för att kunna uppnå en god och stabil elmiljö. Detta examensarbete skall underlätta val av teknik och förhoppningsvis öka kunskapen angående ämnet. / In this report analysis the advantages and disadvantages of the TN-C (four conductor system) and TN-S (five conductor system) system. There are different opinion about which system is most appropriate to use in the distribution network and the building main lines. With the help of literature studies and contacts with various power companies and electric companies different opinion have been discussed . TN-C is the most appropriate option in the distribution network and TN-S should be used in the building main lines. This for achieving high and stable electrical environment. This thesis will facilitate the choice of technology and hopefully increase the knowledge about the subject.
9

Optimering av Savoniusturbinens effektivitet i marina strömmar med hjälp av CFD-analys av flödesriktare / Optimization of Savonius turbine efficiency in marine currents using CFD-analysis of flow directors

Hammar, Leonard, Kovaleff Malmenstedt, Jacob January 2022 (has links)
The Savonius turbine is a self-starting vertical axis turbine that has a few advantages compared to other vertical axis turbines such as lower cost, lower noise and is relatively easy to manufacture. This turbine does however have a lower efficiency and is therefore less used in the electricity production than other turbines.  This thesis is trying to tackle this problem with the use of 2D CFD-simulations of flow directors to modify the flow through the turbine to increase the efficiency. The focus during this project is to use this turbine as a Marine Current Turbine (MCT) in unidirectional flows. The turbine was based on a turbine design from a previous study at Uppsala University. The design of the flow directors was modeled with the intention to increase the available pressure drop from the front to the back of the turbine and therefore increase the velocity through the turbine. The flow directors comprised of two arcs on each side of the turbine so that they resembled a Venturi-tunnel, with a funnel in the front and a diffuser at the back. A validation of the domain dimensions and mesh-size was conducted and after this the different parameters of the flow directors were varied one at a time with the best value of a given parameter being kept for the latter simulations. At the end, the rotational velocity of the turbine was varied to find how sensitive the power output was based on this factor. This study concluded that an increase in the power coefficient of about 3,2 times was achievable compared to the same turbine in free flow. However, this needs to be further investigated and validated in real world tests as this study was conducted using 2D-simulations and other effects may influence the results in the real world. / <p>This project was conducted within Stand up for wind and Stand up for energy.</p>
10

Identifiering av lagerströmmar i elmotorer för framdrivning av tunga fordon : Utveckling av metod och programvara för att detektera lagerströmmar / Identification of Bearing Currents in Electric Motors for Heavy Vehicles : Development of Methodology and Software to DetectBearing Currents

Lindström, Jessica January 2023 (has links)
Klimatutmaningar, lagändringar och ett ökat miljötänk har tvingat transportsektorn att ställa om till eldrift. Batterier och elmotorer har utvecklats kraftigt och är nu ett alternativ även för tunga fordon. Ett vanligt förekommande problem med elmotorer i fordon är lagerströmmar, här kallat gnista eller blixthändelser. Dessa uppstår på grund av oönskade urladdningar i motorn och förorsakar skador på lagren i motorn. Syftet med motorlager är att avlasta och minska friktionen kring motoraxeln. För att förebygga problemet och se förbättringar eller försämringar av olika åtgärder som görs krävs att lagerströmmar kan identifieras utifrån mätdata. Detta examensarbete analyserar relevant forskning inom området för att sedan introducera en metod och en algoritm för att identifiera lagerströmmar i samarbete med Scania CV. Algoritmen består av tre olika parametrar som påverkar identifieringen av de oönskade strömmarna på olika sätt. Verktyget lyckades identifierade lagerströmmar i olika mätdata, och hittade skillnader i antalet blixthändelser mellan olika körningar av provobjektet. Dock krävs vidare utveckling av verktyget och möjligheten att bearbeta annan typ av data som exempelvis spänningar i motorn för atthitta bättre samband. / A changing climate, changing laws and an increased environmental consciousnesshas forced the transport sector to transition to electric power. Batteries and electric motors have seen a quick and powerful development which means that they are now an alternative even for heavy vehicles. A common problem with electric motors forvehicles is bearing currents. The bearing currents occur as a result of electrical discharges in the motor and can damage the bearings inside the motor. The purpose of motor bearings is to offload and reduce friction for the motor shaft. To prevent the issue and to see improvements or deteriorations from different preventativemeasures it is critical to be able to identify bearing currents from data. This thesis analyzes relevant research in the area before introducing a method and an algorithm for detecting bearing currents in cooperation with Scania CV. The algorithm is composed of three different parameters which affects the identification in different ways. The tool was able to identify bearing currents from various data and found differences between the number of bearing currents between different test runs of the motor. However, more development of the tool and the possibility to process different kinds of data like voltages inside the motor is needed to be able to find better patterns in the data.

Page generated in 0.0496 seconds