• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 107
  • 22
  • 15
  • 11
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • Tagged with
  • 426
  • 426
  • 169
  • 167
  • 84
  • 75
  • 64
  • 59
  • 52
  • 48
  • 48
  • 46
  • 46
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Influência da potência de fotoativação e de técnicas de inserção na retenção da restauração de resina composta em raiz fragilizada / Influence of curing light intensity and insertion techniques for composite resin restoration retention in weakened roots

Mendonça, Isabela Lima de 26 January 2016 (has links)
O objetivo deste estudo ex vivo foi avaliar, por meio de teste de pull out, a influência de diferentes potências de fotoativação, associadas a diferentes técnicas de inserção, na retenção da restauração de resina composta em raízes fragilizadas. Foram utilizadas quarenta raízes de caninos superiores humanos padronizadas em 15 mm de comprimento, que foram submetidas à fragilização por meio de brocas 718PM; 730PM e 720PM, com auxílio de paralelômetro numa extensão de 8 mm. O tratamento endodôntico foi realizado por meio de instrumentos manuais tipo K, apenas no remanescente radicular não tocado pela fragilização. A obturação foi realizada pela técnica de condensação lateral com cimento AH Plus, seguida de corte dos cones, no comprimento correspondente à área da fragilização, e toalete da cavidade. Os espécimes foram distribuídos em quatro grupos (n= 10) de acordo com a técnica de inserção e a potência de fotoativação: Grupo I, resina composta inserida em incremento único; Grupo II, resina composta inserida em dois incrementos. Estes grupos foram fotoativados em baixa potência (500 mW/cm²); Grupo III, resina composta inserida em incremento único; Grupo IV, resina composta inserida em dois incrementos. Estes grupos foram fotoativados em alta potência (1200 mW/cm²). Em todos os grupos as raízes foram restauradas internamente com resina composta fotopolimerizável Z100, com fotoativação auxiliada por pinos plásticos fototransmissores, no comprimento de 8 mm, removidos após a polimerização, para a cimentação dos pinos metálicos pré-fabricados Reforpost com cimento resinoso Relyx ARC, o que proporcionou a obtenção do reforço radicular (resina composta + pino metálico). As raízes foram submetidas ao teste de pull out numa máquina universal de ensaios (Intron 3345) à velocidade de 1mm/min até deslocamento do reforço radicular. Os valores de resistência à tração foram expressos em MPa e submetidos à Análise de Variância dois fatores (&alpha;=0,05). A resistência à tração foi influenciada pela potência de fotoativação (P<0,05), mas não pela técnica de inserção da resina composta e nem pela interação dos fatores em estudo (P>0,05). A fotoativação em alta potência apresentou altos valores de resistência à tração (4,38±1,57) em comparação com a fotoativação em baixa potência (2,19±0,82), enquanto que a técnica de inserção em incremento único (3,62±1,60) ou dois incrementos (2,95±1,70) apresentou valores estatisticamente semelhantes. Concluiu-se que o aumento da potência de fotoativação influenciou positivamente na retenção da resina composta utilizada na restauração de raízes fragilizadas, independente da quantidade de incrementos utilizados / The aim of this ex vivo study was to evaluate by pull out test the influence of different curing light intensities, associated to different insertion techniques on the composite resin restoration retention of weakened roots. For this purpose forty maxillary human roots were used. The minimum length was standardized at 15 mm. The roots were weakened using 718PM; 730PM e 720PM drills with the aid of a parallelometer up to a depth of 8mm. Endodontic treatment was performed with K-type hand files only in the root section unreached by the weakening. Root canal filling was performed according to the lateral condensation technique using AHPlus sealer. Then cones were cut up to weakening length and cavity was cleaned.. The samples were assigned to four groups (n= 10) according to the insertion technique and curing light intensity: Group I, composite resin placed in bulk placement; Group II, composite resin placed in two increments. These groups were photoactivated with low intensity curing light (500 mW/cm²); Group III, composite resin placed in bulk placement; Group IV, composite resin placed in two increments. These groups were photoactivated with higth intensity curing light (1200 mW/cm²). In all groups the roots were restored internally with Z100 light-cured composite resin and photoactivated using light-transmitting plastic posts up to a depth of 8 mm. After polymerization the light-transmitting posts were removed. Then prefabricated metal posts were cemented with Relyx ARC resin-based cement, which provided the achieviment of root reinforcement (composite resin + metal post). The roots were subjected to pull out test by a universal testing machine (Intron 3345) at a speed of 1 mm/min until the root reinforcement was dislodged. Resistance values were expressed in Mpa and were subjected by 2-way Analysis of Variance (&alpha;=0,05). Curing light intensity influenced the tensile strength (p<0,05), however for composite resin insertion technique and for interaction between factors under study (P>0,05) no influence was found. Higth intensity curing light showed high tensile strength values (4,38±1,57) compared with low intensity curing light (2,19±0,82) whereas composite resin insertion technique using bulk placement (3,62±1,60) or two increments (2,95±1,70) showed similar values. Increasing the curing light intensity had positive influences on composite resin restoration retention in weakened roots, regardless of the amount of increments used.
192

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Morais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
193

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Renata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
194

Avaliação da influência da pigmentação, opacificador e envelhecimento nas propriedades físicas e mecânicas de um silicone experimental para prótese bucomaxilofacial / Evaluation of the influence of pigmentation, opacifier and aging on physical and mechanical properties of an experimental silicone for maxillofacial prosthesis

Marina Peris Vomero 29 January 2015 (has links)
O objetivo deste estudo foi propor a utilização de um novo silicone (Bio-Skin - BS) para prótese bucomaxilofacial. Foram analisadas alteração de cor, dureza Shore A, resistência à tração, características de superfície (MEV) e composição química (EDS) frente à diferentes pigmentações e envelhecimentos. Como parâmetro de comparação foi empregado o silicone MDX4-4210. Foram obtidos 120 espécimes para cada material com formato circular e 160 em forma de haltere, a partir de matrizes metálicas de corte, os quais foram distribuídos em 4 grupos: PI - pigmentação intrínseca (pó de maquiagem); OP - opacificador (sulfato de bário, BaSO4); PIO - associação de PI + OP; SP - sem adição de PI ou OP. Em seguida, os espécimes foram distribuídos aleatoriamente em 3 subgrupos para exposição ao envelhecimento por luz natural (LN, n=10), luz ultravioleta (UV, n=10) e ausência de luz (C, n=10). O período experimental foi de 12 meses. A alteração de cor foi verificada com auxílio de espectrocolorímetro e sistema CIE L*a*b*. Para a dureza foi utilizado um durômetro Shore A e a análise da resistência à tração foi realizada em máquina universal de ensaio. As variáveis de resposta quantitativas foram mensuradas imediatamente após a obtenção dos espécimes e após o período experimental. A análise de superfície foi realizada por microscopia eletrônica de varredura (MEV) e a composição química dos silicones, por espectroscopia por energia dispersiva (EDS). Os dados foram submetidos à análise de variância e teste complementar de Tukey (p<0,05). Os resultados das análises por MEV e EDS foram apresentados em imagens e gráficos. Houve interação entre todos os fatores (p<0,05) e ambos os materiais sofreram variações em função das pigmentações e envelhecimentos. Para alteração de cor, o silicone experimental (BS) apresentou as menores variações de cor. Analisando os silicones em função da pigmentação, o MDX apresentou maiores variações com os espécimes SP e com OP envelhecidos por luz natural e luz UV. Para o BS, houve alteração significativa da cor dos espécimes SP e OP somente após o envelhecimento por LN. Os dois materiais apresentaram aumento da dureza frente a todas as condições, sendo que o silicone BS apresentou a maior variação. O silicone experimental apresentou resistência à tração superior ao MDX em todas as situações. O MDX não sofreu influência significativa na resistência à tração por nenhuma das pigmentações ou envelhecimento, exceto quanto pigmentado com pó de maquiagem e envelhecido por UV, onde houve aumento da resistência. Quanto ao silicone BS, os maiores valores de resistência à tração foram encontrados com a PI e PIO em todos os grupos de envelhecimento. Pode-se considerar que o material experimental apresentou resultados favoráveis em relação à alteração de cor, dureza Shore A e resistência à tração para sua aplicação clínica em prótese bucomaxilofacial. A associação da pigmentação intrínseca, por meio de pó de maquiagem com opacificador, protegeu o silicone da alteração de cor e promoveu alterações aceitáveis nas propriedades mecânicas dos materiais. Todos os processos de envelhecimento promoveram alterações nas propriedades dos materiais. / The aim of this study was to propose the use of a new silicone (Bio-Skin - BS) for maxillofacial prosthesis. Color change, Shore A hardness, tensile strength, surface characteristics (SEM) and chemical composition (EDS) were analyzed, regarding different pigmentation and aging methods. The MDX4-4210 silicone was used as parameter of comparison. Specimens (120 circular and 160 dumbbell-shaped) were obtained for each material, from metal cutting molds, which were divided into 4 groups: IP - intrinsic pigmentation (makeup powder); OP - opacifier (barium sulfate, BaSO4); IPO - IP + OP association; WP - without adding IP or OP. Then, the specimens were randomly divided into 3 subgroups to aging by exposure to natural light (NL, n = 10), ultraviolet light (UV, n = 10) and without light (C, n = 10). The experimental period was 12 months. The color change was observed with spectrocolorimeter and CIE L*a*b* system. For hardness we used a Shore A durometer and the analysis of tensile strength was performed in a universal testing machine. The quantitative response variables were measured immediately after obtaining the specimens and after the experimental period. The surface analysis was performed by scanning electron microscopy (SEM) and the chemical composition of silicones, by energy dispersive spectroscopy (EDS). Data were submitted to ANOVA and Tukey\'s test (p <0.05). SEM and EDS results were presented in pictures and graphics. There was interaction between all factors (p <0.05) and both materials varied depending on the pigmentation and aging methods. For color change, the experimental silicone (BS) showed the lowest color variations. Analyzing the silicones due to the pigmentation, the MDX showed higher variation with the WP and OP specimens aged in natural light and UV light. For BS, there was significant change in the color of the WP and OP specimens only after aging for NL. The two materials presented an increase in hardness front of all conditions, and the BS silicone showed the greatest variation. The experimental silicone showed superior tensile strength to MDX in all situations. The MDX was not affected in tensile strength by any pigmentation or aging, except for the group pigmented with makeup powder and aged by UV, where there was an increase of resistance. As to BS silicone, the highest tensile strength values were found for the IP and IPO in all age groups. It can be considered that the experimental material showed favorable results regarding color change, Shore A hardness and tensile strength for clinical use in maxillofacial prosthesis. The association of intrinsic pigmentation through makeup powder and opacifier, protected silicone of color change and promoted acceptable changes in mechanical properties of the materials. All the aging processes promoted changes in material properties.
195

"Aspectos de micromorfologia, resistência de união e adaptação à dentina em função do tipo de adesivo e das características da camada de esfregaço" / Micromorphological aspects, bond strength and adaptation to dentin as a function of the type of the adhesive and the smear layer characteristics

Kenshima, Silvia 07 December 2005 (has links)
O objetivo do estudo foi avaliar o efeito de adesivos autocondicionantes com diferentes pHs aplicados em camadas de esfregaço (CE) fina e espessa na sua resistência de união (RU), adaptação marginal (AM) e micromorfologia. Foram utilizados 47 molares (n=5). A dentina oclusal foi exposta e cada dente foi seccionado em duas metades (unidade experimental) preparadas com lixa 600 (CE fina) e 60 (CE espessa). Os sistemas autocondicionantes foram selecionados conforme a acidez: Clearfil SE Bond (SE- fraco), Optibond Solo primer e adesivo (SO-intermediário), TYrian + One Step Plus (TY–forte). Um sistema convencional, ScotchBond Multi-Uso (MP) também foi estudado. A aplicação dos adesivos foi aleatória e uma reconstrução da porção coronária foi realizada com resina Z-250. Após 24h, os palitos para microtração (0,8mm 2 ) foram preparados. Parte deles foi submetida à microtração (Kratos–0,5mm/min). (Um índice de RU foi calculado levando-se em consideração a contribuição relativa dos tipos de fratura ocorridos). A outra parte foi avaliada em microscopia de luz (400x) quanto à AM tendo sido calculada a largura média de fendas (Lm) na interface de união. Para observação do padrão de condicionamento por MEV, os primers autocondicionantes e o H3PO4 foram aplicados à dentina tratada com lixa 60 e 600, removidos com banhos de álcool e acetona, fixados, desidratados com etanol, secos com HMDS e recobertos com ouro. Para observação dos prolongamentos resinosos, unidades experimentais “restauradas" com Z-250 tiveram a dentina removida com HCl e NaHOCl e as amostras recobertas com ouro. Os dados de RU e AM foram submetidos a ANOVA de 2 fatores (p=0,05). Testes de regressão (p=0,05) foram aplicados para RU e Lm e de cada um com o pH dos primers autocondicionantes. Apenas o fator Adesivo foi significante para RU e Lm e não houve relação entre ambos. Observou-se que TY apresentou RU significativamente inferior aos demais sistemas, semelhantes entre si. A Lm foi tanto maior quanto menor a acidez do sistema autocondicionante e MP apresentou a menor Lm. Em condições de CE espessa, as Lm foram significativamente maiores. Notou-se que o sistema de acidez fraca foi o mais afetado pela CE espessa tanto no padrão de condicionamento como na formação de prolongamentos resinosos. Houve maior remoção da CE com o sistema de acidez forte. Concluiu-se que, nas condições experimentais testadas, apenas o sistema convencional conseguiu aliar altos valores de resistência de união a uma boa adaptação marginal, e ainda reunir aspectos de micromorfologia compatíveis / The objective of this study was to evaluate the effect of different pH self-etch adhesives applied to thick and thin smear layer (SL) on bond strength (BS), marginal adaptation (MA) and micromorphology. 47 molars (n=5) were used. The occlusal dentin was exposed and each tooth was sectioned in two halves (experimental unit) prepared with 600-grit SiC paper (thin SL) and 60-grit (thick SL). The self-etch adhesives were selected according to the acidity: Clearfil SE Bond (SE-mild), Optibond Solo primer and adhesive (SO-intermediary), Tyrian + One Step Plus (TY– strong). An etch-&-rinse system, ScotchBond Multi-Purpose (MP) was also studied. The adhesives application was randomized and a resin composite build-up was made with Z-250. After 24h, the microtensile sticks (0.8 mm2) were prepared. Part of them was submitted to the microtensile bond strength test (Kratos-0.5 mm/min). (A BS index was calculated considering the relative contribution of the fracture types observed in the fractured sticks). The other part had the MA evaluated by light microscopy (400x) for the mean interfacial gap width (Gw) calculation. For the conditioning pattern SEM evaluation, the self-etch primers and the phosphoric acid was applied to dentin (60 and 600-grit), removed with baths of alcohol and acetone, fixed, dehydrated with ethanol, dried with HMDS and gold sputtered. For resin tags observation, restored experimental units were used. The dentin was removed with HCl and NaHOCl and gold sputtered. The BS and MA data was analyzed by 2-way ANOVA (p=0.05). The regression test (p=0.05) was performed for BS and Gw and for both with the self-etch primers pH. A regression test was applied for Gw and Li to evaluate their relationship (p=0.05). Only the Adhesive was significant for BS and Gw and no there was no relationship for them. TY presented significantly lower BS compared to the other adhesives that had similar BS. The higher the pH of the self-etch primers, the larger were the corresponding Gw (Gw x pH regression was significant). MP presented the lowest Gw. With thick SL, the Gw was significantly larger. The mild self-etch adhesive was affected by the thick SL in both the conditioning pattern and tags formation. The SL removal was more extensive with the strong self-etch. It was concluded that only the etch-&-rinse system achieved high BS and good MA with compatible micromorphological aspects
196

Efeito do armazenamento em água na resistencia de União de diferenets abordagens de adesão a dentina / Effects of water storage on resin-dentin bond strengths formed by different bonding approaches

Martins, Gislaine Cristine 21 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4206631 bytes, checksum: c89ea8320c5c7cd1115382f7f0e02b50 (MD5) Previous issue date: 2008-02-21 / The purpose of this study was to evaluate the effects of water storage on resindentin bond strengths [μTBS] formed by different adhesive bonding approaches. A flat superficial dentin surface the 24 human third molars were exposed and polished to create a standardized smear layer. The teeth were randomly distributed into four different: total-etch 3 step (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP), and total-etch 2 step (Adper™ Single Bond 2, 3M ESPE - SB); self-etch 2 step (AdheSE, Ivoclar/Vivadent - AD); and self-etch 1 step (Adper™ Prompt™ LPop ™, 3M ESPE - LP). Following the adhesive application (n=6), resin composite crowns were incrementally placed (Filtek™ Supreme XT - 3M ESPE) in order to obtain bonded sticks, with a cross-sectioned area of about 0,8 mm2. The bonded sticks were randomly divided and assigned to be tested immediately [IM] (n=30) or after 6 months of water storage [6M](n=30). Two-way ANOVA and Tukey’s test showed that none of the adhesives showed degradation after 6 months, except SB, which was the one that achieved the highest μTBS either in the immediate time (49.13 MPa) and after 6 months (40.27 MPa). LP showed the lowest μTBS in both periods of evaluation (18.35 and 18.34 MPa). AD and SBMP showed intermediate performance. But the SB showed lower μTBS significantly after storage anyway showed high results. Conclusion: Although a significant degradation was only observed for SB, this was the adhesive that showed the highest μTBS after 6M of water storage. It seems that the microtensile test is not sensitive to detect degradation for adhesives with low immediate μTBS. / Este estudo objetivou avaliar o efeito do armazenamento em água na resistência de união [μTBS] de diferentes abordagens de adesão à dentina. As superfícies oclusais de 24 terceiros molares hígidos foram cortadas, planificadas e, a smear layer padronizada. Os dentes foram divididos aleatoriamente em 4 grupos de acordo com a abordagem de união, ou seja, convencionais, de 3 passos (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP) e, de 2 passos (Adper™ Single Bond 2, 3M ESPE -SB); autocondicionantes, de 2 passos (AdheSE, Ivoclar/Vivadent - AD) e, de 1 passo (Adper™ Prompt™ L-Pop™, 3M ESPE - LP). Após o procedimento adesivo (n=6) os dentes foram restaurados pela técnica incremental com resina composta Filtek™ Supreme XT (3M ESPE). Obteve-se 240 espécimes em forma de palitos com área aproximada de 0,8 mm2. Dos espécimes obtidos para cada grupo (n=60), metade foi submetido ao teste de resistência de união imediato [IM] (n=30) e, a outra metade foi armazenada em água para realização do teste após 6 meses de armazenamento [6M](n=30). A ANOVA 2 fatores e o pós-teste de Tukey mostraram que não ocorreu degradação após 6M, exceto para o SB, ainda assim, a maior média da resistência de união IM e 6M foi do SB (49.13 e 40.27 MPa). O LP mostrou as menores médias nos dois períodos de avaliação (18.35 e 18.34 MPa). O AD e o SBMP apresentaram desempenho intermediário. Entretanto, o SB apresentou redução significativa da resistência de união após 6M, apesar disso, obteve os melhores resultados. Concluiu-se que embora ocorreu uma degradação significativa para o SB, este sistema foi o que apresentou maior μTBS após 6 meses de armazenamento em água. O teste de microtração não foi sensível para detectar a degradação dos sistemas adesivos com valores mais baixos de μTBS.
197

EFEITO DA INCLUSÃO DE PARTÍCULAS DE CARGA NA RADIOPACIDADE E EM PROPRIEDADES DE SISTEMAS ADESIVOS EXPERIMENTAIS / Effects of of filler addition to experimental adhesives on radiopacity and properties

Martins, Gislaine Cristine 13 November 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4074240 bytes, checksum: e09201e7bd1d75eac883e17325cc0c46 (MD5) Previous issue date: 2012-11-13 / The aim of this study was to evaluate the radiopacity, ultimate tensile strength (UTS), microhardness (KHN), degree of conversion (DC), water sorption (WS), solubility (SO), microtensile bond strength (μTBS) and of experimental dental adhesives with increased addition of barium-borosilicate zirconia nanoparticles or glass microparticles. Methods: Ten experimental adhesive systems with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 35(EX35) and 50%(EX50) and barium-borosilicate oxide microparticles [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] were formulated based on the adhesive system Ambar (FGM). The adhesive Adper Single BondTM 2 (SB, 3M ESPE) was used as commercial reference. For the radiopacity (n=5), KHN (n=5), WS (n=10) and SO (n=10) tests, adhesive specimens were constructed using a stainless steel mold (5.0 mm in diameter and 1.0 mm in deep), while for UTS (n=5), a hourglass shape metallic matrix (10 mm long, 2 mm wide, and 1 mm deep with cross-sectional area of 0.8 mm2) was employed.The FTIR spectra of uncured and cured specimens of adhesives were used to determine the DC of the materials. For μTBS, adhesives were applied to flat dentin surfaces of third molars (n=7). Resin composite buildups were constructed and sectioned to obtain resin-dentin bonded sticks to tested immediately (IM) or after 6 months (6M) of water storage. Data were submitted to a one-way ANOVA and Tukey´s test (α=0.05). Results: All experimental bonding adhesives showed radiopacity similar to enamel. Only R60 showed higher UTS than the other materials. The experimental adhesives showed higher KHN values when compared to the commercial SB. In general, the DC of the experimental solutions was not affected by filler addition and was statistically higher than SB. Although filler addition did not affect WS, it generally reduced the SO. Most of the experimental adhesives showed lower WS and SO than SB. Conclusions: Both the addition of nanoparticles as microparticles were able to confer radiopacity to adhesives experimental, and adding load influence on the properties tested. In general, it can be said that the best performance was for the addition of microparticles in a concentration of 30%. / Objetivo: Este estudo objetivou avaliar a radiopacidade, resistência máxima à tração,(RMT), microdureza (KHN), grau de conversão (GC), sorção de água (SA),solubilidade (SO), resistência de união (μTBS) de sistemas adesivos experimentais pela adição de nanopartículas de zircônia ou micropartículas de vidro de bárioborosilicato. Material e métodos: Dez sistemas adesivos experimentais com diferentes concentrações de nanopartículas de zircônia [0(EX0), 15(EX15), 25(EX25), 35(EX35) e 50%(EX50) ou com micropartículas de óxido de bário-borosilicato [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] foram formulados tendo como base o sistema adesivo Ambar (FGM). O sistema adesivo Adper Single BondTM 2 (SB, 3M ESPE) foi utilizado como referência comercial. Foram confeccionados espécimes de adesivo para os testes de radiopacidade (n=5), KHN (n=5), SA (n=10) e SO (n=10) utilizando matriz metálica com 5,0 mm de diâmetro e 1,0 mm de profundidade e, para a RMT (n=5) uma matriz metálica com 10 mm de comprimento, 2 mm de largura, 1 mm de profundidade e, área de sessão transversal de 0,8 mm2. Os espectros FTIR foram obtidos de espécimes não polimerizados e polimerizados dos adesivos para determinar o GC dos materiais. Para μTBS, aplicou-se os adesivos na superfície de dentina de dentes molares humanos (n=7). Os dentes foram reconstruídos com resina composta e cortados para obtenção de espécimes em forma de palitos que foram testados imediatamente (IM) ou após 6 meses de armazenamento em água (6M). Os dados foram submetidos a ANOVA e pós-teste de Tukey´s (α=0,05). Resultados:Todos os sistemas adesivos experimentais mostraram radiopacidade semelhante a do esmalte dental. Apenas o R60 mostrou valores de RMT mais elevado que os outros materiais. Os sistemas adesivos experimentais apresentaram valores mais altos de dureza Knoop quando comparado ao SB. Em geral, o GC dos adesivos experimentais não foi afetado pela adição de partículas e, significantemente superior ao SB. A maioria dos adesivos experimentais mostraram menor SA e SO que o SB.Conclusões: Tanto a adição de nanopartículas quanto de micropartículas foi capaz de conferir radiopacidade aos adesivos experimentais e, a adição de carga influenciou nas propriedades testadas. De modo geral, pode-se dizer que o melhor desempenho foi para a adição de micropartículas na concentração de 30%.
198

Efeito da incorporação de cobre nas propriedades mecânicas e adesivas à dentinas de um sistema adesivo universal / Effect of copper incorporation on mechanical and adhesive properties of a universal adhesive system

Hanzen, Taíse Alessandra 20 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-09-11T14:03:43Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Taise Hanzen.pdf: 2068610 bytes, checksum: 63860393bd79b5a0ebafdc98b4fd73e2 (MD5) / Made available in DSpace on 2018-09-11T14:03:43Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Taise Hanzen.pdf: 2068610 bytes, checksum: 63860393bd79b5a0ebafdc98b4fd73e2 (MD5) Previous issue date: 2018-02-20 / O propósito deste estudo in vitro foi avaliar o efeito da adição de nanopartículas de cobre em um sistema adesivo universal sobre a resistência de união (RU) e nanoinfiltração (NI) da interface resina-dentina hígida, erosionada e cariada, nas estratégias adesivas convencional (total-etch [TE]) e autocondicionante (self-etch [SE]). Bem como grau de conversão (GC), morfologia da interface de união (MI), resistência máxima à tração (RT), sorção cumulativa de água (SO) e solubilidade (SB) do sistema adesivo e radiopacidade do cobre (RC). O sistema adesivo experimental foi formulado com a adição de nanopartículas de cobre a 0,1% no adesivo Ambar Universal. Para os testes de RU e NI, 120 molares humanos foram aleatoriamente distribuídos em doze condições experimentais (n = 10) com base na combinação das variáveis: concentração de cobre [0 e 0,1%] vs. superfície dentinária (hígida, erosionada e cariada) vs. estratégias adesivas (TE e SE). Aplicado o sistema adesivo, os dentes foram restaurados com resina composta e após 24h, seccionados longitudinalmente para se obter palitos de resina-dentina (0,8 mm2), testados em tensão a 0,5 mm/min quanto a RU. Para NI, 3 palitos de cada dente foram preparados e analisados em microscopia eletrônica de varredura (MEV). Para avaliação do GC, 3 palitos de resina-dentina de cada condição experimental foram analisados por espectroscopia Raman. Para MI, 3 palitos de resina-dentina foram preparados e analisados por FEG. Para RT, 5 corpos de prova de adesivo de cada condição experimental foram testados nos tempos imediato (24h) e após 28 dias de armazenamento (n = 10). Para SO e SB, 10 corpos de prova de adesivo (n=10) de cada condição experimental foram testados durante o período de 56 dias. Para avaliação da RC, 5 corpos de prova de cada condição experimental (n = 5) foram submetidos a 5 radiografias digitais, para comparação em escala de cinza. Os dados de RU, NI e GC foram analisados por ANOVA 3 fatores, submetidos ao teste post-hoc de Tukey para múltiplas comparações. Para RT, os dados foram analisados por ANOVA 2 fatores para medidas repetidas. Os dados de RC foram analisados por ANOVA fator único. Os dados de SO e SB foram submetidos à análise por test-t pareado. A significância estatística foi predefinida em 5%. A inclusão de nanopartículas de cobre na concentração 0,1% no sistema adesivo universal aumentou os valores de RU sobre os substratos hígido e erosionado. O adesivo contendo cobre melhorou a NI no substrato hígido, em ambas as estratégias. Para RT, RC, SO e SB, a adição de cobre não apresentou diferenças estatísticas. O GC foi mais afetado em substrato erosionado quando na técnica convencional associada ao adesivo contendo cobre, que resultou na formação de tags menores e em quantidade reduzida. / The purpose of this in vitro study was to evaluate the effect of addition of copper nanoparticles on a universal adhesive system in microtensile bond strength (μTBS) and nanoleakage (NL) of sound, eroded and carious resin-dentin interface, using both self-etch [SE] and total-etch [TE] adhesive strategies. As well as degree of conversion (DC), interface micromorphology (IM), ultimate tensile strength (UTS), cumulative water sorption (WS) and solubility (So) of the adhesive system and copper radiopacity (CR). The experimental adhesive system was formulated with the addition of 0,1% copper nanoparticles on Ambar Universal. For μTBS and NL, 120 human third molars were randomly distributed in 12 experimental conditions (n=10) based on the combination of the variables: concentration of copper [0 and 0,1%] vs. dentin surface (sound, eroded and carious) vs. adhesive strategies (TE and SE). After bonding procedures and restored with composite resin, teeth were stored for 24h and then longitudinally sectioned to obtain specimens – dentin-resin sticks (0,8mm2), tested in a tension of 0,5mm/min for μTBS. For NL, 3 specimens per tooth were prepared and analyzed by scanning electron microscopy (SEM). For DC, 3 sticks of resin-dentin of each experimental condition were analyzed by Raman spectroscopy. For IM, 3 sticks of resin-dentin were prepared and analyzed by FEG. For UTS, 5 samples of each condition were tested after 24 hours and 28 days of storage (n = 10). For WS and So, 10 samples of each experimental condition (n = 10) were tested during 56 days. For radiopacity, 5 CPAs of each experimental condition (n = 5) were submitted to 5 digital radiographs, for comparison in gray scale in Adobe Photoshop Software. The data of μTBS, NL and DC (Raman) were analyzed by three-way ANOVA, submitted to Tukey's post hoc test for multiple comparisons. For UTS, data were analyzed by two-way ANOVA. For CR, data were analyzed by one-way ANOVA. The data of WS and So were evaluated by Student’s T-test. Statistical significance was set at α = 0.05. The inclusion of 0,1% of copper nanoparticles on the universal adhesive system improved μTBS values on sound and eroded substrates. The copper adhesive improved NL on sound dentin, for both strategies. For UTS, radiopacity, WS and So, the addition of copper showed no statistical difference in the results. DC was most affected by eroded dentin associated with ER strategy and adhesive containing copper, which resulted in smaller tags, in reduced quantity.
199

Inter-relação do comprimento dos prolongamentos resinosos (tags) e da espessura da camada híbrida de adesão, com a resistência de união de sistemas adesivos ao tecido dentinário /

Rahal, Vanessa. January 2009 (has links)
Orientador: Renato Herman Sundfeld / Banca: André Luiz Fraga Briso / Banca: Alma Blásida Concepcíon Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi analisar a correlação da espessura da camada híbrida de adesão e do comprimento dos prolongamentos resinosos (tags), com a resistência de união em tecido dentinário hígido, de um sistema adesivo convencional e de outro autocondicionante. Após a realização "in vivo" dos procedimentos restauradores, os dentes foram extraídos e seccionados no sentido mésio/distal. Em uma secção dental foi realizada a análise microscópica dos prolongamentos resinosos e da camada híbrida de adesão. Para tanto, os espécimes foram descalcificados, incluídos em parafina e cortados a uma espessura de 6 μm. Os cortes foram corados pelo método Brown e Brenn, para posterior análise e mensuração em microscópio óptico comum Axiophot Zeiss em 1000× (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). O remanescente dental foi acoplado à cortadeira metalográfica ISOMET 1000 (Buehler, Lake Bluff, IL, USA), de forma a permitir a realização de secções transversais, destinados ao teste de microtração (Instron modelo 4411 - Instron Inc., Canton, MA, EUA), sendo tracionados a 0,5 mm/min até sua ruptura. A superfície fraturada foi classificada segundo o padrão de fratura após análise sob lupa estereoscópica Stemi SV 11 (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden-Württemberg, Germany) em aumento de 40×. Os valores obtidos no teste de microtração, na análise dos tags e da camada híbrida correspondentes a cada espécime e grupo de estudo, foram submetidos à análise estatística, com a realização do teste de Correlação de Pearson, não sendo verificada correlação entre os valores de resistência de união e a espessura da camada híbrida e comprimento dos tags resinosos em nenhum dos sistemas adesivos estudados. / Abstract: The purpose of this study was to evaluate the possibility of the correlation between the hybrid layer thickness, the resin tag length, and the resin bond strength of a conventional and a self-etching adhesive system into sound dentin tissue. After "in vivo" restorative procedures were performed, each specimen was extracted and sectioned in a mesiodistal direction. One of the dental sections was then analyzed on a light microscope where the hybrid layer thickness and resin tag length were measured. For this experiment, the specimens were decalcified, embedded in paraffin and serially sectioned at a thickness of 6 μm. The sections were subsequently stained using Brown and Brenn stain for posterior analysis and for the measurement of the hybrid layer thickness and the resin tag length on a Zeiss Axiophot light microscope at 1000× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The other section was mounted onto a metallographic cutter ISOMET 1000 (Buehler, Lake Bluff, IL, USA) and was sectioned. A microtensile test was subsequently performed (Instron modelo 4411 - Instron Inc., Canton, MA, USA) with a crosshead speed of 0.5 mm/min. The fractured surfaces were analyzed and the fracture pattern was characterized using a stereoscopic magnifying glass Stemi SV 11 at a 40× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The results were subjected to Pearson Correlation Test and verified that the hybrid layer thickness and the resin tag length did not correlate with the bond strength of the adhesives systems. / Mestre
200

Comparação da resistência de união de diferentes superfícies dentinárias na obtenção dos espécimes para microtração / Effect of different dentin surfaces on the microtensile bond strength values

Maria Angelica Silverio Agulhari 18 May 2015 (has links)
Com intuito de aumentar a longevidade das restaurações, diversos sistemas adesivos são disponibilizados no mercado e, com isso, muitos estudos são conduzidos, dentre eles, a resistência de união desses sistemas. A maioria dos trabalhos utiliza o teste de microtração. Este teste permite a avaliação de diferentes superfícies, gerando variedade nos resultados obtidos e dificultando a comparação de dados. Este estudo teve como objetivo comparar os valores de resistência de união para as diferentes superfícies de dentina utilizadas em testes de microtração (dentina planificada e dentina de paredes cavitárias, com túbulos dentinários dispostos predominantemente paralelos ou perpendiculares à interface adesiva). Foram utilizados 80 terceiros molares humanos, divididos aleatoriamente em 4 grupos e 2 subgrupos, de acordo com a superfície dentinária de obtenção dos espécimes e do sistema adesivo utilizado: G1 (PO) planificação da face oclusal (baixo fator C); G2 (PV) planificação da face vestibular (baixo fator C); G3 (CP) face pulpar de preparo cavitário oclusal (alto fator C); G4 (CV) face vestibular de preparo oclusal (alto fator C). Dois diferentes sistemas adesivos foram utilizados: convencional de 3 passos Adper Scotchbond Multi-Purpose (3M ESPE) e o autocondicionante de 2 passos Clearfil SE Bond (kuraray), resultando em 8 subgrupos (n=10): POSMp; POCf; PVSMp; PVCf; CPSMp; CPCf; CVSMp; CVCf. A resina composta (Filtek Z250 A3) foi inserida em dois incrementos horizontais. Após 48 horas, os dentes foram seccionados com disco diamantado para a obtenção dos palitos com área de seção transversal de ±0,8mm. Uma fatia de cada subgrupo foi separada para análise em MEV. Os espécimes foram fixados ao dispositivo de microtração tipo Bencor multi T adaptado à máquina de ensaios universal Instron. Uma força de tração com velocidade de 0,5 mm/min utilizando uma célula de carga de 500N foi aplicada. As superfícies fraturadas foram analisadas em Esteromicroscópio LeicaMZ6 para identificar e classificar o tipo de fratura. Os resultados foram submetidos ao teste ANOVA a 2 critérios e ao teste de Tukey com nível de significância de 5%, para cada tipo de adesivo. Os valores médios (MPa±dp) foram: POSMp: 44.51±9.28; PVSMp: 56.75±6.58; CPSMp: 27.88±5.71;CVSMp: 32.54±6.11; POCf: 48.34±8.09; PVCf: 52.51±10.18; CPCf: 23.06±5.93; CVCf: 31.35±4.03. Houve diferença estatisticamente significante para o tipo de preparo (p<0.01 para ambos adesivos) e para a orientação dos túbulos dentinários (p<0,001 para o Scotchbond Multipurpose e p=0.012 para o Clearfil SE Bond).. Concluiu-se, portanto, que os espécimes obtidos a partir de cavidades apresentaram redução nos valores de resistência de união e a orientação paralela dos túbulos em relação à interface adesiva aumentou os valores de resistência de união à microtação. / Microtensile test is usually used to evaluate bond strength values and can be affected by several factors resulting in a diversity of values which makes it difficult to compare data. Flat surfaces dentin are used in most studies. However, specimens from a tooth cavity preparation can be a more realistic model. The aim of this study was to compare &#x3BC;TBS values of dentin flat surfaces (low C factor) and dentin from cavity preparations (high C fator) and its relation with the direction of the dentin tubules. Eighty extracted caries-free human molars were assigned into 4 groups: OF (occlusal flat surface specimens low C factor); BF (buccal flat surface specimens low C factor); PC (pulp surface of cavity preparations specimens high C factor) and BC (buccal surface of cavity preparations specimens high C factor). Each group was divided into 2 subgroups according to the adhesive system Adper Scotchbond Multi-Purpose (3M ESPE) or Clearfil SE Bond (Kuraray), resulting in 8 groups (n=10): OFSMp; OFCf; BFSMp; BFCf; PCSMp; PCCf; BCSMp and BCCf. Two horizontal increments of Filtek Z250 resin were used to restore the teeth. After 48 hours storage, the specimens were sectioned into 0.8 mm beams with diamond disc for microtensile test and submitted to a tensile force in a Universal Testing Machine (Instron) at 0.5mm/min. One slice of each subgroup was randomly selected for MEV. Mean values (MPa±sd) were OFSMp: 44.51±9.28; BFSMp: 56.75±6.58; PCSMp: 27.88±5.71; BCSMp: 32.54±6.11; OFCf: 48.34±8.09; BFCf: 52.51±10.18; PCCf: 23.06±5.93; BCCf: 31.35±4.03. Data were statistically analyzed by two-way ANOVA and Tukeys test (p<0.05) for each adhesive. The adhesive failures were predominant in all groups. It can be concluded that the microtensile bond strength was influenced by the type of dentin surface and tubules orientation. The specimens obtained from cavity preparations showed reduced &#x3BC;TBS (p<0.01). Parallel tubules orientation showed a statistically significant increase of &#x3BC;TBS (p<0.001 for Scotchbond Multipurpose and p=0.012 for Clearfil SE Bond).

Page generated in 0.088 seconds