• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 140
  • 120
  • Tagged with
  • 260
  • 207
  • 173
  • 111
  • 101
  • 52
  • 47
  • 46
  • 44
  • 35
  • 34
  • 30
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Väderprognosstyrda värmesystem i byggnader : En jämförelse mot traditionell styrning / Weather-forecast controlled heating systems in buildings : A comparison with traditional control systems

Andersson, Victor January 2019 (has links)
The aim of this essay is to investigate how forecast control can affect the energy consumption and the top effects for heating compared to the traditional control system in facilities with different building structures. In 2013 were the energy consumption 80 TWh for the heating and domestic hot water in resident buildings and facilities. This corresponds to 55 % of the total energy consumption within the building sector and facilities represent 28 % of the buildings. This indicates that there is room for efficiency for the heating systems in facilities.Demands from new directives for stricter energy consumptions for buildings are going to be established in the Swedish regulations and 19:th of June 2018 were the new amending directives published which need to be established in the Swedish regulations latest 10 March 2020. The demands on the buildings is pushed further and further. It is getting more difficult to reach the requirements from BBR and even more difficult to reach the requirements from environmental certifications like Miljöbyggnad. Therefore, it is important with detailed solutions that is able to lower the energy consumptions for the heating systems.A reference building has been used and created in the simulation software IDA ICE with three different building constructions to compare forecast control against the traditional control system. One with a large U-value and low amount of thermal mass, one with a smaller U-value and a low amount of thermal mass and one with a smaller U-value and a high amount of thermal mass.The centrally controlled forecast control is tested against the traditional controlled system for each building structure. Traditional controlled systems in facilities is normally using thermostatic valves, due to the lack of sustainability and the lack of maintenance the control systems are also tested without the thermostatic valves.The results for the forecast control indicate on an increase for the energy saving by 3.4 % without the thermostatic valves and an increase by 2.7 % with the thermostatic valves. The top effects can be improved with forecast control by 33 % without thermostatic valves and by 15 % with thermostatic valves. These improvements were made for the building construction with high amount of thermal mass. It is possible to argue for benefits with forecast control if it is installed in a heavy constructed building with regard to the decreased top effects. It is more difficult to argue for the benefits with regard to the energy consumption. Large benefits were found with in local control, especially for buildings with large U-value and low amount of thermal mass. The result indicated on an improvement of 30 % for the traditional control with thermostatic valves and of 28 % for the forecast control with thermostatic valves compared to the scenario without the thermostatic valves.Knowledge about the building characteristics has a significance for the choice of control system. According to the results forecast control may be a benefit with regard to the top effects if it is a heavy building construction. Regarding the energy consumption is the best strategy to carefully adjust and maintain the current traditional control system. / Denna rapport har i avsikt att undersöka hur energianvändningen och värmeeffekterna för uppvärmning påverkas med prognosstyrning i jämförelse med traditionell styrning av värmesystem i lokaler av olika byggnadskonstruktioner. 2013 var energianvändningen 80 TWh för uppvärmning och tappvarmvatten i hushåll och lokalbyggnader. Detta motsvarade då 55 % av den totala energianvändningen inom sektorn där lokaler representerar 28 % av byggnaderna. Med andra ord finns det utrymme för effektivisering av uppvärmningen i lokaler.Krav från direktiv om skärpt energianvändning av byggnader måste införas i svenska regler. Den 19 juni 2018 publicerades nya ändringsdirektiv som måste vara införda i svenska regler senast den 10 mars 2020. Kraven på byggnader blir allt hårdare för att uppnå kraven som ställs från BBR och så även för att uppnå miljöcertifieringar som miljöbyggnad. Det blir alltså allt viktigare att hitta detaljlösningar som kan minska på energianvändningen på byggnader.För att ställa prognosstyrning mot traditionell styrning har en referensbyggnad använts. Den har byggts upp i simuleringsverktyget IDA ICE med tre olika byggnadskonstruktioner. Ett med både högt U-värde och liten termisk massa (originalkonstruktion), en med lägre U-värde men fortfarande liten termisk massa (lätt konstruktion) och en med lägre U-värde och mycket termisk massa (tung konstruktion).Den centralt styrda prognosstyrningen prövades sedan mot den traditionella styrningen för respektive byggnadskonstruktion. Med traditionell styrning används vanligtvis termosstatventiler i lokaler men då hållbarheten på dessa är låg vilket också underhållet av dessa kan vara, prövas även båda strategierna utan termostatventiler också.Resultatet visar att prognosstyrningen förbättrar energianvändningen som mest med 3.4 % i det fallet termostatventiler inte används och 2.7 % i det fallet termostatventiler används. Effekttopparna kan förbättras med 33 % utan termostatventiler och 15 % med termostatventiler. Dessa förbättringar genererades med den tunga konstruktionen. En tung konstruktion kan visa på fördelar med prognosstyrning med avseende på lägre effekttoppar. Utifrån resultaten går det däremot inte att se några fördelar med avseende på energianvändningen.Stora fördelar kunde däremot gå att se med lokal reglering med termostatventiler, vilket var särskilt gynnsamt för byggnader med högt U-värde och låg termisk massa. Resultatet visade då på en förbättring med 30 % för den traditionella styrningen och 28 % för prognosstyrningen när jämförelse med om de inte användes.En god förståelse av byggnadsstommens karaktär har en betydande roll för valet av reglersystem. Prognosstyrning kan vara fördelaktigt med avseende på toppeffekterna, framför allt med den tunga konstruktionen i resultatet. För att minska på energianvändningen är det dock troligtvis viktigast att se över och injustera det befintliga systemet på både central som lokal nivå.
142

A hybrid low - temperature heating system in geothermal retrofitting for public buildings in the Mediterranean climate

Bizimana, Boumediene January 2019 (has links)
More than 50 % of EU’s yearly energy demand is spent on heating and cooling systems with which most of its source is generated from non-renewable fossil fuel [1]. Furthermore, half of the EU buildings are heated with a non-efficient boiler of about 60% or less efficiency [1]. The report released by EU from 1990 to 2007 revealed that fuel combustion and fugitive emission contribute to about 79.3% of total greenhouse gas emissions in CO2 equivalents [1]. The EU-EBPD long-term renovation strategy is to improve the energy performance of all residential and non-residential buildings in its member countries through supporting the renovation of the existing buildings into highly energy efficient and decarbonised buildings [2]. Despite all these EU policies and efforts to replace these non-efficient heating systems, the main challenge is price comparison of different solutions and their efficiency in retrofitting of the heating old systems together with the lack of information about the functioning of those old systems [1]. Thus, the development of an easy to install heating system in retrofitting with low exergy heat supply is a significant contribution to a sustainable solution in minimizing energy resources depletion and environmental emission. Furthermore, efficient system control of these easy to install heating systems, hybrids combinations solution for retrofitting building could be a sustainable solution for the preservation of the existing building. The main objective of this work was to design an easy to install hybrid low-temperature floor heating system in retrofitting buildings and compare its results on energy performance, thermal comfort and indoor air quality with other conventional heating mainly used in the Mediterranean climate. This study was performed in two existing radiators heated buildings located in Sant Cugat del vallès in Catalonia, Spain.The results showed that the hybrid low-temperature heating system has the highest energy performance and energy saving of 48 % and 52% compared to that of existing radiator heating and all air heating, respectively. However, hybrid low-temperature floor heating showed a slow heating response, and consequently, it showed lower operative temperature compared to others even though it was within the recommended standards limits. The hybrid low-temperature heating system with demand-controlled ventilation also showed a better indoor air quality, while as existing radiator with its natural ventilation showed the worst indoor air quality. All three compared heating systems showed a better coefficient of performance with low-temperature heat supply and were able to operate with low-temperature heat supply. / Mer än 50% av EU:s årliga energibehov spenderas på värme- och kylsystem där de flesta av deras källor genereras från icke-förnybart fossilt bränsle [1]. Dessutom värms hälften av EU:s byggnader upp med en ineffektiv panna med cirka 60% eller mindre effektivitet [1]. EU:s rapport från 1990 till 2007 avslöjade att bränsleförbränning och flyktiga utsläpp bidrar till cirka 79% av de totala utsläppen av växthusgaser i koldioxidekvivalenter [1]. EU:s och EBPD:s långsiktiga renoveringsstrategi är att förbättra energiprestanda för alla bostäder och andra byggnader i dess medlemsländer genom att stödja renovering av befintliga byggnader till mycket energieffektiva byggnader [2].Trots alla dessa EU-policyer och ansträngningar för att ersätta dessa ineffektiva värmesystem, är den största utmaningen prisjämförelse av olika lösningar och deras effektivitet i renovering av de gamla värmesystemen tillsammans med bristen på information om hur de gamla systemen fungerar [1]. Därför är utvecklingen av ett installationsenkelt värmesystem med låg värmeförsörjning av exergi ett viktigt bidrag till en hållbar lösning för att minimera energiresurser och miljöutsläpp. Dessutom kan effektiv systemkontroll av dessa värmesystem med olika kombinationslösningar för renovering av byggnaden vara en hållbar lösning för att bevara den befintliga byggnaden.Huvudsyftet med detta arbete var att utforma ett lågtemperaturgolvvärmesystem att använda vid renovering av byggnader och jämföra dess resultat på energiprestanda, termisk komfort och inomhusluftkvalitet med annan konventionell uppvärmning som huvudsakligen används i medelhavsklimat. Denna studie utfördes i två befintliga radiatoruppvärmda byggnadet i Sant Cugat del vallès i Katalonien, Spanien. Resultaten visade att hybridsystemet med låg temperatur har den högsta energiprestandan och energibesparingen på 48% och 52% för den befintliga radiatorvärme respektive luftvärme. Emellertid visade lågtemperaturgolvvärme ett långsamt uppvärmningssvar, och följaktligen visade det lägre driftstemperatur jämfört med de andra systemen trots att det låg inom de rekommenderade standardgränserna. Lågtemperaturvärmesystem med efterfrågningsstyrd ventilation visade också en bättre inomhusluftkvalitet, medan befintliga radiatorer med sin naturliga ventilation visade den sämsta inomhusluftkvaliteten. Alla tre jämförda värmesystemen visade bättre prestanda med lågtemperaturvärmeförsörjning och kunde fungera med lågtemperaturvärmeförsörjning.
143

Thermal degradation of PFAS in solid matter / Termisk nedbrytning av PFAS i fast materia

Al-Badri, Tuqa January 2024 (has links)
Per- och Polyfluorerade alkylsubstanser (PFAS) är syntetiskt framställda organiska föreningar som har använts i stor utsträckning i konsument- och industriprodukter. PFAS-substanser besitter attraktiva egenskaper såsom resistans mot väta, fett, fläckar och är dessutom värmetåliga. De används i bland annat brandskum, smink, vattentäta kläder med ”andas-funktion”, möbler och non- stickstekpannor. Den senaste forskningen har dock visat att PFAS utgör en fara för levande organismer och miljön. Vissa PFAS-substanser har klassats som persistenta, bioackumulativa och toxisk (PBT), samt väldigt persistenta och väldigt bioaccumulativa (vPvB).Existerande forskning har fokuserat på beteendet hos PFAS i olika miljöer. Dock finns det en kunskapslucka när det gäller hur dessa PFAS-substanser beter sig under termiska behandlingsprocesser, samt förbränningsgraden i kommersiella förbränningsanläggningar vid temperaturerna 850–950 °C. I detta projekt undersöks därför nedbrytningsgraden av PFAS genom förbränning samt bildning av potentiellt farliga biprodukter efter förbränning. För att genomföra denna studie skulle förbränning av PFAS-haltigt avloppsslam i en pilotskalig bubblande fluidiserad bädd (BFB) genomföras. På grund av hinder utfördes experimenten i stället i en konventionell och simpel laboratorieugn. Dessutom genomfördes en litteraturstudie för att undersöka bildandet av potentiellt farliga biprodukter efter förbränning av PFAS. Denna studie har visat att termisk behandling genom förbränning är en effektiv metod för att behandla PFAS i avloppsslam med reduktion under kvantifieringsgränserna. Undersökning av potentiellt farliga biprodukter baserat på litteraturstudier har visat att kortkedjiga PFCAs var mest förekommande i aska, vätska och gasformiga rester efter termisk behandling. Några undersökningar tyder på att termisk behandling av PFAS-haltigt material möjligen resulterar i ozonnedbrytande ämnen. Utifrån den genomförde litteraturstudien i detta projekt saknas starka bevis för att kunna påstå att det bildas ozonnedbrytande ämnen under förbränning av PFAS. / Per- and polyfluoroalkyl substances (PFAS) are man-made organic compound widely used in consumer and industrial products. They exhibit attractive properties such as resistance to water, heat, and grease. Therefore, PFAS are used in fire foam, non-stick pans, water-resistant clothes, make-up, and furniture. Recent studies have revealed that PFAS substances can be harmful to humans, animals, and the environment. Some PFAS substances have, therefore, been classified as persistent, bioaccumulative, and toxic (PBT), and very persistent and very bioaccumulative (vPvB). This means that PFAS resists degradation, accumulates in living organisms and biota, and inherits toxic effects. In previous and current research, the focus has been on the behavior of PFAS in different environmental settings. However, there is a gap in research on how these PFAS substances behave during thermal treatment processes in commercial facilities at temperatures of 850-950 °C and how effective the thermal degradation is. This project investigates the effectivity of thermal degradation via combustion and the fate of PFAS post-combustion, focusing on the formation of potentially hazardous by-products. Therefore, the combustion of PFAS-containing sewage sludge in a bench- scale bubbling fluidized bed (BFB) was to be conducted to fulfill the objective of this study. Due to hindrances, the experiments were performed in a conventional furnace furnace instead. Also, a literature study was conducted to investigate the fate of PFAS after combustion. From this study, it was concluded that thermal treatment via combustion at temperatures 850 and 950 °C is an effective method to degrade PFAS in sewage sludge. Also, the literature study investigation revealed that persistent short-chain PFCAs were most abundant in the ash, liquid, and gaseous residues after thermal treatment. A few investigations indicate that thermal treatment of PFAS-containing matter possibly results in ozone-depleting compounds. Based on the conducted literature study, there is a lack of strong evidence that supports the claim of the formation of ozone- depleting compounds during combustion of PFAS.
144

Gear Modifications for Optimal Load Distribution / Växelmodifiering för optimal lastfördelning

Adimoolam Ganesan, Raghunath January 2023 (has links)
In the early days of gear manufacturing, engineers aimed to produce teeth as close to the theoretical shape as possible. As machinery advanced and demand for high-speed, high-torque, and quieter transmissions grew, optimizing gear teeth became increasingly important [1]. Techniques such as tip and root relief reduced engagement shocks, while lead modifications like lead slope and crowning increased load-carrying capacity. Gas turbines are complex, high-load machines that require the use of suitable gearboxes with highly reliable components. The importance of this reliability cannot be overstated, as any downtime can result in significant financial repercussions. By implementing the right modifications, it is possible to reduce the causes of failure and improve the overall performance of the gearboxes, leading to more efficient and cost-effective operations. The primary focus of this thesis is to explore the use of various modification methods to achieve the most optimal load distribution across the face width of a double helical gear. This is accomplished through the use of FVA workbench and analytical calculations, allowing for a thorough and comprehensive analysis of these modifications. / Ingenjörer när växeltillverkning var i sin linda, hade som avsikt att producera kuggar så nära dess teoretiska form som möjligt. I takt med att maskiner utvecklades ökade proportionell efterfrågan på transmissioner med hög hastighet och vridmoment med tystare drift, sedan dess har optimeringen av kuggarna fått grepp. Profilmodifieringar som topp- och fotavlättning minskade ingreppsstötar, på engelska ”lead modification”, ”lead slope” och ”crowning” ökade lastkapaciteten. Gasturbiner är höglastade maskiner som kräver behov av lämplig växellåda med behov av mycket pålitliga komponenter för att minska och eventuellt undvika stillestånd då antalet maskiner är många och det kommer att kosta mycket i sådana fall. Om det görs rätt kan modifieringar minska orsakerna till fel och förbättra växellådornas prestanda. Denna avhandling behandlar användningen av dessa modifieringsmetoder för att erhålla den mest optimala lastfördelningen över kuggflanken på en snedkuggsväxel, vilket görs med FVA-Workbench och analytiska beräkningar.
145

CFD-simulering av värmeöverföring under upptändningsförlopp av krutraketmotor

Olsson Sjögren, Carl-Otto January 2024 (has links)
SAAB Dynamics producerar och utvecklar flertalet produkter som innehåller krutraketmotorer. Krutraketmotorers prestanda är kraftigt beroende av en effektiv upptändning och det är önskvärt att kunna prediktera detta förlopp numeriskt med god noggrannhet. Ingen etablerad simuleringsmetodik existerar i dagsläget. Detta examensarbete är ett första steg mot att undersöka hur anfyrningsförloppet kan modelleras med Computational Fluid Dynamics. Den komersiella mjukvaran Ansys Fluent har använts som simuleringsverktyg. Anfyrningsförloppet är ett transient förlopp och involverar flertalet komplicerade värmeöverföringsmekanismer. Några av de viktigaste mekanismerna är konvektiv värmeöverföring från anfyrningsgaser, värmeledning från anfyrningspartiklar och termisk strålning från både gaserna och partiklarna. Tre modeller presenteras. De modellerar en approximativ geometri från tidigare experimentella undersökningar och simulerar 2,4 millisekunder av anfyrningsförloppet. Inga kemiska reaktioner modelleras. Modell 1 simulerar konvektiv värmeöverföring från heta förbränningsgaser. Modell 2 inkluderar termisk strålning från förbränningsgaserna som modelleras med Planck-medelvärdes absorptionskoefficienter och Discrete Ordinates modellen. Totalt värmeflöde och slutgiltig temperaturfördelning längs krutranden redovisas. Modellerna predikterar liknande värmeflöden och temperaturfördelningar, med något förhöjda nivåer för modell 2. Ett experimentellt uppmätt tryck används för att validera trycknivåer i simuleringarna. Fysikalisk rimlighet av anfyrningsgasens temperatur bedöms även med den adiabatiska flamtemperaturen. Båda modeller presterar väl med avseende på dessa mått. En tredje modell som försöker modellera anfyrningspartiklar med hjälp av Discrete Phase Model presenteras även. Modellen anses inte tillförlitlig då den lider av numeriska problem för det simulerade fallet. Avslutningsvis diskuteras felkällor och fortsatt arbete för samtliga modeller. / SAAB Dynamics produces and develops several products that use solid-propellant rocket engines. The performance of these rocket engines is heavily dependant upon an efficient ignition. It is desirable to be able to predict this sequence numerically with good accuracy. No established simulation methodology exists as of today however. This master thesis is a first step towards the investigation of how the initial ignition sequence can be modelled using Computational Fluid Dynamics. The commercial software Ansys Fluent has been used as a tool for simulation. The initial heat transfer during ignition is a transient sequence and involves several complex heat transfer mechanisms. Some of the most important ones include convective heat transfer from ignition gases, conduction from ignition particles as well as thermal radiation from both the gases and particles. Three models are presented. They model an approximate geometry from earlier experimental investigations and simulate 2.4 milliseconds of the initial ignition sequence. No chemical reactions are modelled. Model 1 simulates convective heat transfer from hot ignition gases. Model 2 includes thermal radiation from the ignition gases that is modelled using Planck-mean absorption coefficients and the Discrete Ordinates model. Total heat transfer rates and final temperature distributions along the surface of the propellant are reported. The models predict similar total heat transfer rates and final temperature distributions, with somewhat elevated levels for model 2. An experimentally measured pressure is used to validate the simulated pressure levels. Physical validity is also evaluated by comparing the temperature of the ignition gas to the adiabatic flame temperature. Both models perform satisfactorily with regards to these metrics. A third model that attempts to model the ignition particles using the Discrete Phase Model is also presented. The model is deemed unreliable due to numerical problems for the simulated case. Finally sources of error and possible future work is discussed.
146

Heat and fluid control solutions for deep space CubeSat CGPS

Byström-Troyan, Filipp January 2021 (has links)
This thesis is on the subject of how propellant heating considerations affect the design of a CubeSat cold gas propulsion system. Computer simulation tools are used to analyse heat flow through the system, as well as the fluid flow and phase change of butane. The heating performance is presented for different operational states and different designs. Finally, an optimal system design is suggested. The propulsion system in question is the deep space heading Hera Juventas 6DOF CGPS. The Juventas spacecraft will as part of ESA’s Hera mission be the first to perform radar measurements of an asteroid. It will determine the result of the NASA DART mission and will give insights to the internal structure of the Dimorphos minor- planet moon. / Detta examensarbete behandlar utformningen av ett CubeSat kallgasframdrivningssystem med avseende på drivmedelsuppvärmning. Datorsimuleringsverktyg används för att analysera värmeflöde genom systemet samt flödet och fasförändringen av butan. Värmningsprestanda presenteras för olika driftstillstånd och olika konstruktioner. Slutligen föreslås en optimal systemdesign. Framdrivningssystemet i fråga är Hera Juventas 6DOF CGPS. Rymdfarkosten Juventas kommer som en del av ESA:s Herauppdrag att vara den första som utför radarmätningar av en asteroid. Den kommer att avgöra resultatet av NASA:s DARTuppdrag och kommer att ge insikter om den interna strukturen i asteroidmånen Dimorphos.
147

Initiation of rolling contact fatigue from asperities in elastohydrodynamic lubricated contacts

Everitt, Carl-Magnus January 2018 (has links)
Rolling contacts are utilized in many technical applications, both in bearings and in the contact between gear teeth. These components are often highly loaded, which makes them susceptible to suffer from rolling contact fatigue. This work focuses on the rolling contact fatigue mechanism of pitting. In order to attain a better understanding of why pitting initiates and grows, detailed simulations of rolling contacts have been performed. In particular the contact between two gears in a truck retarder was here used as a case study. The investigated contact experienced elastohydrodynamic lubrication conditions since the load was high enough to causes the surfaces in contact to deform and the viscosity of the lubricant to increase significantly. In Paper A it was investigated if surface irregularities in the size of the surface roughness are large enough to cause surface initiated fatigue. The investigation focused on the pitch line since small surface initiated pits were found here even though there was no slip present. Since there were pits present at the pitch line, it is important that the theories of pitting can explain the development of pits also in the absence of slip. The conclusion of the work was that surface irregularities of the size of normal surface roughness are enough to cause surface initiated fatigue at the pitch line. In Paper B it was investigated why pits are more likely to initiate in the dedendum of pinion gears than in the addendum. In both areas slip is present but in different directions. In the dedendum the friction from slip is against the rolling direction which enhances the risk for pitting. The investigation was performed by studying the effect of the temperature rise in the contact caused by the slip. The conclusion drawn was that the temperature rise in the contact explained why pitting was more common in the dedendum than in the addendum. / Rullande kontakter förekommer i många applikationer, till exempel i lager och mellan kugghjulständer. Både lager och kugghjul utsätts ofta för höga laster vilket gör att dess ytor löper stor risk att utmattas, vilket kallas rullande kontaktutmattning. Denna studie fokuserar på pitting, även kallat spalling, vilket är en typ av rullande kontaktutmattning där en utmattninsspricka växer fram som får delar av ytan att ramla av. För att få en bättre förståelse varför pittingskador uppkommer har noggranna simuleringar utförts av rullande kontakter. Kontakten mellan två tänder på kugghjul i en lastbilsretarder har används som underlag då många pittingskador påträffats på dem.  För att minska friktionen och nötningen i kontakten mellan kuggtänderna användes smörjmedel. De höga lasterna lastbilsretardern utsattes för deformerade kuggarnas ytor elastiskt samtidigt de kraftigt ökade viskositeten hos smörjmedlet. Dessa förhållanden gör att kontakten kallas för elastohydrodynamiskt smord, vilket på engelska förkortas till EHL. I Artikel A undersöktes om små ytojämnheter kan orsaka ytinitierade pittingskador. Eftersom skadan påträffats i friktionslösa kontakter, så som vid rullcirkeln på de undersökta kugghjulen, är det viktigt att teorierna som förklarar uppkomsten inte är beroende av friktion. Undersökningen fokuserade därför på förhållandena vid rullcirkeln.  Slutsatsen från arbetet var att små ytojämnheter, av samma storleksordning som ytojämnheterna på de undersökta kugghjulen, är tillräckligt stora för att orsaka utmattningsskador. I Artikel B undersöktes varför det är vanligare att pitts initieras i dedendum än addendum på drivande kugghjul. Kontakten på båda sidorna om rullcirkeln slirar svagt åt olika håll. Att kontakten slirar skapar friktion som är motriktad rullriktningen i dedendum vilket ökar risken för pittingskador. För att undersöka varför dessa förhållanden ökar risken för skador fördjupades analysen av kontakten genom att inkludera temperaturfältet. Simuleringarna visade att temperaturen ökar genom kontakten vilket orsakar en asymmetrisk spänningsfördelning. Denna asymmetriska spänningsfördelning gör att ytojämnheter i dedendum är troligare att orsaka skador än ytojämnheter i addendum. / <p>QC 20180213</p>
148

Genom eld och vatten : En studie om brandsäkerhet för laddning av elfordon ombord på fartyg.

Brouwer, Karlijn January 2024 (has links)
Laddning av eldrivna fordon ombord på fartyg innebär betydande säkerhetsutmaningar. Detta examensarbete utforskar riskerna förknippade med denna process och undersöker hur dessa kan förhindras. Metoden är en litteraturundersökning av befintlig forskning. Vi identifierar och utvärderar riskerna med att ladda litiumjonbatterier ombord på fartyg och granskar även relevanta regelverk och standarder för skyddsåtgärder. Resultaten visar att batterihälsa och batterityp påverkar fordonets säkerhet samt att termisk rusning är en risk. Termisk rusning kan upptså vid mekaniska, elektriska, eller termiska skador. För att hantera dessa risker finns det flertal skyddsåtgärder såsom Battery management system som övervakar batteriets kondition och förhindrar överladdning. Andra åtgärder inkluderar säkringar, brytare, bimetallsiska termostater samt postiva termiska koefficienter. Lastbalansering är även viktig för att minska riskerna. Disskussione betonar vikten av säkerhetsåtgärder samt regelverk för att säkerställa en trygg laddningsprocess ombord på fartyg. Genom att implementera de identifierade skyddsåtgärder kan sjöfarten ta betydande steg mot en hållbar och säker framtid.
149

Badrumsrenovering i bostäder : Jämförelse mellan radiatorsystem och golvvärmesystem ur energi-, fukt- och komfortaspekt i Västerås

Davidsson, Lukas, Alsterlund, Isak January 2019 (has links)
This degree project cover renovation of sanitary rooms with focus on an exchange from a radiator system to an underfloor heating system out of the three aspects energy, moisture and thermal comfort. The used method is literature study, interview, case study and calculations. When a radiator system is replaced with an underfloor heating system the energy demand will decrease due to a possible temperature reduction. The power requirement for the bathrooms will be reduced if the finish material have a higher density and the volume of the room is small. The moisture aspect can in some cases deteriorate with the replacement of systems. It is possible to achieve the same thermal comfort with any system, but it is easier to adjust with an underfloor heating system. An exchange from a radiator system to an underfloor heating system is possible. The energy and thermal comfort aspects improves, but the moisture aspect will potentially degrade.
150

Assessment of Energy Recovery Technology in China : Mechanical ventilation system with energy recovery

Piippo, Kaj January 2008 (has links)
<p><!-- --></p><p>In the wake of the economic growth of the Chinese market the past couple of decades, the energy consumption has surged. One of the biggest consequences of the increased energy consumption is a massive increase in CO<sub>2</sub> emission. In fact, China has overtaken the U.S. as the biggest emitter of CO<sub>2</sub>. In light of this energy-saving technology gets more important to implement. District heating is one of the solutions used with success in parts of China where heating is required. In this paper, an energy recovery technology has been examined for two climate zones in China namely a mechanical ventilation system using a flat-plate counter-flow heat exchanger. Beijing is located in a cold zone while Hong Kong is located in a zone with hot summers and mild winters. Cooling load calculations were conducted manually using the RTS - method developed by ASHRAE and heating load calculations were conducted for Beijing using Swedish guidelines stated in BBR. Further, the energy recovery unit (VM1) that was provided by Systemair AB was tested using a rig where different outdoor conditions were simulated. This data was then used to evaluate the potential for energy recovery in a model apartment located in the two zones. As expected, significant differences were obtained when comparing the performance for the two locations.</p><p> </p> / Redan avklarad

Page generated in 0.0392 seconds