• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 11
  • 3
  • Tagged with
  • 39
  • 25
  • 10
  • 9
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Neuroimmunologie : études cliniques pour mesurer l'effet de l'ajustement chiropratique sur la température cutanée, la variabilité du rythme cardiaque et les cytokines (protéine réactive-C et interleukine-6)

Roy, Richard 09 1900 (has links) (PDF)
L'objet de cette thèse est l'évaluation de l'effet du traitement chiropratique sur des variables physiologiques. Il y a peu d'information sur l'effet du traitement chiropratique sur la température cutanée paraspinale. De plus, il y a peu d'information sur la technologie de thermométrie utilisée pour faire ces évaluations. Plusieurs recherches ont été effectuées pour mesurer l'effet des traitements chiropratiques cervicaux ct dorsaux sur la variabilité du rythme cardiaque, mais il n'y a aucune étude qui mesure les effets des traitements chiropratiques lombaires. La littérature fournit peu de documentation sur l'effet des traitements chiropratiques sur les hormones pro-inflammatoires. Il n'y a aucune information sur l'effet des traitements chiropratiques sur l'interleukine-6 et la protéine réactive C. Les hypothèses visaient à mesurer s'il y a des effets produits par des traitements chiropratiques sur les variables énumérées ci-haut : la température cutanée paraspinale; la variabilité du rythme cardiaque et les hormones pro-inflammatoires. La méthodologie était progressive. Le premier projet évaluait l'effet du traitement chiropratique sur des sujets sans douleurs au cours d'un seul traitement. Le traitement chiropratique a été effectué avec un instrument (Activator IV). Deux périodes d'adaptation furent utilisées pour mesurer la réaction de la température cutanée paraspinale selon la période d'adaptation. Le deuxième projet évaluait l'effet du traitement chiropratique de sujets en douleurs lors d'un seul traitement traditionnel et il n'y a eu qu'une seule période d'adaptation. La période d'adaptation a été choisie à partir du projet 1 et elle représentait la période d'adaptation qui semblait la mieux adaptée cliniquement. Le traitement a été effectué avec la main, selon la méthode Diversified. Ce projet nous a permis de mesurer les effets de l'ajustement chiropratique sur la TC de sujets en douleurs et de comparer ces résultats à ceux des sujets sans douleur du projet 1. De plus, il a été possible de mesurer le transfert de chaleur de la main du clinicien et de comparer ces mesures à l'effet de l'instrument utilisé dans le projet 1. Pour le troisième projet, nous avons recruté des sujets avec douleurs et des sujets sans douleurs. Ce projet évaluait l'effet du traitement chiropratique sur la variabilité du rythme cardiaque. Les deux techniques chiropratiques des projets 1 et 2 ont été utilisées. Il y avait une période d'acclimatation de trois minutes et les mesures de la VRC ont été enregistrées pendant les cinq minutes qui suivaient ces trois minutes initiales. Le traitement chiropratique a été effectué et il y avait une autre période d'enregistrement de cinq minutes après le traitement chiropratique. Les mesures temporelles et spectrales ont été analysées. Le quatrième projet évaluait l'effet du traitement chiropratique sur des sujets en douleurs chroniques pour une période de neuf traitements échelonnée sur deux semaines. Il y avait un groupe-témoin dont les sujets étaient sans douleurs. Nous avons mesuré pour chaque groupe l'indice de fonctionnalité de Oswestry (questionnaire sur la douleur et la fonctionnalité); la température cutanée paraspinale; la variabilité du rythme cardiaque et les hormones pro-inflammatoires, soit l'interleukine-6 et la protéine réactive C. Les résultats du projet 1 ont démontré que l'ajustement chiropratique avec instrumentation avait un effet sur la température cutanée paraspinale. Toutefois, pour le projet 2, il y a une différence lors de l'évaluation de la mesure obtenue immédiatement après le traitement. Dans le projet 1, il y avait un refroidissement alors que dans le projet 2, il y avait un réchauffement. Le reste des enregistrements étaient très similaires. Les résultats du projet 3 ont été mitigés et ont révélé que la variabilité du rythme cardiaque avait subi une certaine influence provenant d'une manipulation lombaire. Les résultats du projet 4 étaient multiples. L'indice d'Oswestry a démontré que les valeurs du groupe-traitement avaient tendance à se rapprocher des valeurs du groupe-témoin. Pour ce qui est de la température cutanée paraspinale, celle du groupe-traitement était plus froide que celle du groupe-témoin avant le traitement. Après neuf traitements, les valeurs des variables du groupe-traitement avaient tendance à se rapprocher des valeurs des variables du groupe-témoin, les valeurs pré et post des variables du groupe témoin n'ayant pas changé. Les données sur la variabilité du rythme cardiaque ont démontré que les valeurs du groupe-traitement avaient tendance à se rapprocher des valeurs du groupe-témoin. De même, les valeurs des données de l’IL-6 et de la PRC ont démontré la même tendance, à savoir se rapprocher des valeurs du groupe-témoin. En conclusion, même s'il y avait des effets sur la température cutanée paraspinale, il est impossible en ce moment d'utiliser la technique de thermométrie en milieu clinique. En effet, comme il n'existe aucune base de données normative, il est impossible de conclure sur la valeur de l'effet de l'ajustement chiropratique. Quant à la variabilité du rythme cardiaque, il appert que l'effet serait un réflexe d'origine supraspinale plutôt qu'un effet direct sur le système nerveux autonome. Pour ce qui est des hormones pro-inflammatoires de l'IL-6 et de la PRC, il semble que ces mesures soient similaires aux tendances des valeurs de l'indice Oswestry à la suite d'un traitement chiropratique sur des sujets en douleurs. ______________________________________________________________________________ MOTS-CLÉS DE L’AUTEUR : Thermométrie, chiropratique, diagnostoque, variabilité du rythme cardiaque, cytokines.
12

Cardiac MR thermometry for the monitoring of radiofrequency ablation / Thermométrie IRM pour le suivi des ablations radiofréquences sur le cœur

Toupin, Solenn 07 December 2016 (has links)
Le traitement des arythmies cardiaques par ablation radiofréquence est une procédure thérapeutique permettant de restaurer un rythme normal par destruction thermique des tissus arythmogènes. A l'heure actuelle, l'intervention est réalisée sans imagerie temps réel permettant de visualiser la lésion pendant l'ablation. La thermométrie IRM permet de mesurer la température du tissu en chaque pixel et d'estimer directement l'étendue de la lésion via le calcul de la dose thermique cumulée. Si cette technique est déjà établie pour guider l'ablation de tumeurs dans différents organes, elle reste difficile à mettre en œuvre sur le cœur, notamment à cause des mouvements de respiration et de contraction myocardique. Dans le cadre de cette thèse, une méthode de thermométrie cardiaque a été implémentée pour réaliser une cartographie temps réel de la température du myocarde en condition de respiration libre. Plusieurs séquences IRM rapides ont été développées pour permettre l'acquisition d'environ 5 coupes par battement cardiaque avec une taille de voxel de 1.6X1.6X3 mm3. Plusieurs solutions de réduction des mouvements hors plan de coupe ont été évaluées : positionnement des coupes dans le sens principal du déplacement, suivi dynamique de la position des coupes en fonction de l'état respiratoire (navigateur, mesure de la position du cathéter). Le mouvement résiduel et les artéfacts de susceptibilité associés sont corrigés par des algorithmes temps réels pour permettre une précision de la thermométrie IRM à ±2°C sur les ventricules. Ce protocole a été utilisé avec succès pour le suivi d'ablations radiofréquences chez la brebis (N=3), permettant une corrélation (R=0.87) entre la dose thermique et la taille réelle des lésions induites. Les résultats sont très prometteurs quant à la pertinence de cette mesure pour une estimation en ligne de l'étendue de la lésion pendant l'ablation. Ces méthodes permettent d'envisager une évaluation clinique à court terme. / Radiofrequency ablation is a therapeutic procedure for the treatment of cardiac arrhythmia by inducing a local necrosis of the arrhythmogenic tissue. This intervention is currently performed without online imaging of the lesion formation during radiofrequency delivery. MR thermometry provides a monitoring of temperature in the targeted tissue in each pixel and an immediate estimation of lesion via the calculation of the thermal dose. If this technique is well established for the guidance of tumor ablation in various organs, it remains challenging in the heart due to motion (breathing and myocardial contraction). In this work, a cardiac MR thermometry method was developed to perform a real-time temperature mapping of the heart under free-breathing conditions. Several MR pulse sequences were designed to ensure the acquisition of up to 5 slices per heartbeat with a voxel size of 1.6X1.6X3 mm3. Different solutions of minimization of out-of-plane motion were evaluated: alignment of the slices in the main direction of displacement, dynamic update of slice position depending on the respiratory state (echo-navigator, measure of the catheter position). Residual in-plane motion and associated susceptibility artifacts were corrected by real-time algorithms to allow a precision of MR thermometry of ±2°C in ventricles. This protocol was successfully used for the monitoring of radiofrequency ablation in sheep (N=3), allowing a correlation (R=87) between thermal dose maps and sizes of created lesions. These results are promising regarding the relevance of this measure for an inline estimation of the lesion extent during ablation.
13

MR-guided thermotherapies of mobile organs : advances in real time correction of motion and MR-thermometry / Thermothérapies guidées par IRM sur organes mobiles : avancées sur la correction en temps réel du mouvement et de la thermométrie

Roujol, Sébastien 25 May 2011 (has links)
L'ablation des tissus par hyperthermie locale guidée par IRM est une technique prometteuse pour le traitement du cancer et des arythmies cardiaques. L'IRM permet d'extraire en temps réel des informations anatomiques et thermiques des tissus. Cette thèse a pour objectif d'améliorer et d'étendre la méthodologie existante pour des interventions sur des organes mobiles comme le rein, le foie et le coeur. La première partie a été consacrée à l'introduction de l'imagerie rapide (jusqu'à 10-15 Hz) pour le guidage de l'intervention par IRM en temps réel. L'utilisation de cartes graphiques (GPGPU) a permis une accélération des calculs afin de satisfaire la contrainte de temps réel. Une précision, de l'ordre de 1°C dans les organes abdominaux et de 2-3°C dans le coeur, a été obtenue. Basé sur ces avancées, de nouveaux développements méthodologiques ont été proposés dans une seconde partie de cette thèse. L'estimation du mouvement basée sur une approche variationnelle a été améliorée pour gérer la présence de structures non persistantes et de fortes variations d'intensité dans les images. Un critère pour évaluer la qualité du mouvement estimé a été proposé et utilisé pour auto-calibrer notre algorithme d'estimation du mouvement. La méthode de correction des artefacts de thermométrie liés au mouvement, jusqu'ici restreinte aux mouvements périodiques, a été étendue à la gestion de mouvements spontanés. Enfin, un nouveau filtre temporel a été développé pour la réduction du bruit sur les cartographies de température. La procédure interventionnelle apparaît maintenant suffisamment mature pour le traitement des organes abdominaux et pour le transfert vers la clinique. Concernant le traitement des arythmies cardiaques, les méthodes ont été évaluées sur des sujets sains et dans le ventricule gauche. Par conséquent, la faisabilité de l'intervention dans les oreillettes mais aussi en présence d'arythmie devra être abordée. / MR-guided thermal ablation is a promising technique for the treatment of cancer and atrial fibrillation. MRI provides both anatomical and temperature information. The objective of this thesis is to extend and improve existing techniques for such interventions in mobile organs such as the kidney, the liver and the heart. A first part of this work focuses on the use of fast MRI (up to 10-15 Hz) for guiding the intervention in real time. This study demonstrated the potential of GPGPU programming as a solution to guarantee the real time condition for both MR-reconstruction and MR-thermometry. A precision in the range of 1°C and 2-3°C was obtained in abdominal organs and in the heart, respectively. Based on these advances, new methodological developments have been carried out in a second part of this thesis. New variational approaches have proposed to address the problem of motion estimation in presence of structures appearing transient and high intensity variations in images. A novel quality criterion to assess the motion estimation is proposed and used to autocalibrate our motion estimation algorithm. The correction of motion related magnetic susceptibility variation was extended to treat the special case of spontaneous motion. Finally, a novel temporal filter is proposed to reduce the noise of MR-thermometry measurements while controlling the bias introduced by the filtering process. As a conclusion, all main obstacles for MR-guided HIFU-ablation of abdominal organs have been addressed in in-vivo and ex-vivo studies, therefore clinical studies will now be realized. However, although promising results have been obtained for MR-guided RF-ablation in the heart, its feasibility in the atrium and in presence of arrhythmia still remains to be investigated.
14

Intération du modèle du signal IRM pour la correction du mouvement et segmentation d'images automatisée : application à la thermométrie cardiaque / MRI signal model integration for the motion correction and automated images segmentation : Application to cardiac thermometry

Emilien, Aurelie 15 December 2014 (has links)
Les travaux présentés dans ce manuscrit s’inscrivent dans un projet de thermométrie cardiaque par IRM. L’objectif de cette approche est de monitorer en temps réel le traitement des arythmies cardiaques par ablation thermique. Dans la chaine de traitement utilisée, des méthodes de recalage d’images doivent être implémentées afin d’assurer un suivi exploitable de l’ablation. En effet, les mouvements des différents organes localisés dans la (les) coupe(s) d’imagerie ont un impact sur la précision de la thermométrie IRM. Les méthodes d’estimation de mouvement doivent cependant être robustes aux différents artefacts (faible SNR, flux sanguin dans les cavités cardiaques, etc.) et utilisables en pseudo temps réel (10 images/seconde). Les travaux présentés dans ce manuscrit se concentrent sur la robustesse des méthodes de recalage d’images. Tout d’abord, le bruit inhérent aux images IRM a été intégré à l’estimation de mouvement. Ceci permet de pondérer localement les voxels de l’image dans le calcul du déplacement. Ensuite, une annulation numérique du signal chaotique du sang à l’intérieur du ventricule gauche est proposée via une segmentation semi-automatique de celuici à base de modèle déformable. Un nouveau terme, issu de la probabilité d’appartenir à ce ventricule, a été ajouté dans l’algorithme de contour actif. Les méthodes proposées apportent une amélioration de la qualité de l’estimation du mouvement. Elles sont adaptées à la chaine de traitement de thermométrie afin de les rendre automatiques dans la phase d’ablation thermique de la procédure. De plus, ces méthodes répondent aux contraintes de temps réel de la thermométrie IRM / The works presented in the manuscript are incorporated within the framework of cardiac MR thermometry. The aim of this approach is to monitor in real time the treatment of arrhy²thmias by thermal ablation. In the pipeline used in thermometry, image registration methods have to be inserted to unsure a reliable monitoring of the treatment. Indeed, motions of the different organs present in the acquisition slices have an impact on the accuracy of the MR thermometry. Furthermore, image registration has to be robust to artefacts (low SNR, blood flow in the heart cavities…) and has to be used in real time (10 images/second). The works presented in this manuscript focuses on the robustness of the image registration methods. First, the MR images inherent noise is integrated to the motion estimation. It enables the local weighting of the image’s voxels in the computing of the displacement. Then, a numerical cancelation of the chaotic blood flow signal within the left ventricle through a semi-automatic segmentation is proposed. A new term based on the probability to belong to this ventricle is added to the active contour algorithm. The proposed methods improved the quality of the motion estimation. They are adapted to the thermometry pipeline to make them automatic in the thermal ablation phase of the procedure. They are also compatible with the real-time aspect of MR thermometry.
15

Thermométrie submicrométrique par fluorescence:<br />Caractérisation de micro et nanostructures en milieux sec et liquide

Low, Peter 28 February 2008 (has links) (PDF)
Ce travail concerne le développement et l'optimisation de la thermométrie par fluorescence en milieu sec et liquide pour caractériser thermiquement des fils de dimensions submicrométriques dont l'échauffement est obtenu par effet Joule. En utilisant des simulations en éléments finis, les paramètres des fils sont étudiés afin d'optimiser leur comportement thermique. Un fort confinement spatial de la température autour des fils en nickel sur un substrat de silicium est observé grâce à des mesures en fluorescence. Concernant le temps de réponse, des constantes de temps thermiques en dessous de la milliseconde sont obtenues expérimentalement. Les résultats présentés dans cette thèse sont d'un grand intérêt pour le développement de nouveaux outils pour la détection, la reconnaissance et l'étude fondamentale des molécules (dépliement et repliement de protéines et d'ADN par exemple) sous modulation thermique rapide.
16

Dissémination de la température thermodynamique par des points fixes à haute température : vers une nouvelle mise en pratique du kelvin / Dissemination of the thermodynamic temperature using high-temperature fixed-points : towards a new "mise en pratique du kelvin"

Bourson, Frédéric 22 December 2017 (has links)
Les recherches consacrées aux points fixes à haute température (PFHT) ont été intensifiées depuis 1996, suite à une recommandation du Comité Consultatif de Thermométrie de développer des références au-delà de 2000 °C. Les Laboratoires Nationaux de Métrologie se sont alors engagés dans le développement de PFHT construits à partir d'alliages de métal et de carbone. Ces points fixes ont montré des transitions de phase à des températures reproductibles indépendamment de la proportion de carbone dans le métal. Les projets internationaux qui ont suivis les premiers developpements ont permis d'accroitre la robustesse et la stabilité à long terme des points fixes et ont mis en évidence l'importance des conditions thermiques de mise en œuvre. Aujourd'hui ces points fixes montrent une reproductibilité de l'ordre de 0.1 °C et sont en voie de renforcer l'exactitude des mesures pyrométriques aux plus hautes températures, jusqu'ici limitée par l'incertitude d'extrapolation dans l'Echelle Internationale de Température (EIT-90). Un projet de mesure par voie radiométrique de la température thermodynamique des PFHT les plus étudiés a été récemment mené. Les résulats de ces mesures absolues permettent aujourd'hui d'aborder la future mise-en-pratique du kelvin à haute température, par des méthodes de dissémination directe de la température thermodynamique sans recours à l'EIT-90. Ce document décrit les principales étapes depuis la conception de ces nouvelles références, jusqu'à la mesure de leur température thermodynamique. / Research dedicated to high-temperature-fixed-points (HTFPs) have been intensified since 1996, further to a recommendation of the Consultative Committee for Thermometry to develop references above 2000 °C. National Laboratories of Metrology envolved in the development of HTFPs based on metal-carbon alloys. These fixed points showed phase transitions at reproducible temperatures independently to the proportion of carbon in the metal. The international projects that followed the first developments allowed increasing the robustness and the long-term stability of the fixed points and highlighted the importance of the thermal conditions of implementation. Today these fixed points show a reproducibility of about 0.1 °C and are on the way to strengthen the accuracy of radiation thermometry measurements at high temperatures, up to now, limited by the uncertainty of the International Temperature Scale (ITS-90). A project to measure the thermodynamic temperature of the most studied HTFPs by a radiometric method was recently led. Results of this absolute measurement is a step towards the future mise en pratique of the kelvin at high temperature, by a direct dissemination of the thermodynamic temperature without any link to the ITS-90. This document describes the main steps from the conception of these new references, up to the measurement of their thermodynamic temperature.
17

Validation d’une nouvelle génération de sondes HIFU en utilisant la thermométrie IRM / Validation of a new generation of HIFU probes while using MRI thermometry

Petrusca, Lorena Mihaela 14 December 2009 (has links)
L’objectif principal du projet concerne l’étude sous contrôle IRM de nouveaux transducteurs HIFU pour la thérapie. Le premier sous-projet vise la caractérisation d’une sonde HIFU pour le traitement des varices et l’optimisation des paramètres de tir en fonction de la profondeur de la veine dans le tissu. Des mesures acoustiques avec un hydrophone ont confirmé la création d’une ligne de focalisation. Une étude ex vivo utilisant des veines humaines excisées a été réalisée avec l’IRM de température haute résolution afin d’établir des paramètres d'efficacité et de sécurité. La deuxième partie est une étude de sonde sectorielle pour le traitement du cancer de la prostate. La méthode utilisée actuellement par Ablatherm a été comparée avec la méthode sectorielle, en alternant les deux secteurs de la sonde. Les résultats montrent que la forme et les dimensions de la lésion sont les mêmes, avec un gain de temps est de 20%. Troisièmement nous avons étudié une sonde à focalisation dynamique pour le traitement du cancer de la prostate. La validation in vitro et in vivo a été effectuée. Des points focaux distants de 32 à 69mm de la sonde ont été obtenus et des séquences décrivant des lignes, des tranches et des volumes ont été testées. Les cartes de température et de dose thermique montrent que la stratégie de sonication est adéquate pour induire une dose létale homogène de la forme désirée, ce qui permet un traitement mieux adapté en fonction l’anatomie de chaque patient. L’IRM nous a permis de mesurer de façon non-invasive et en temps réel la température au sein des tissus soumis au tir ultrasonore et de visualiser le volume détruit ainsi que les tissus adjacents / The main objective of the project concerns the study of new HIFU transducers for therapy using MRI guidance. The first sub-project aims the characterization of a HIFU probe for the treatment of the varices and the optimization of the shooting parameters according to the vein depth in the tissue. Acoustic measurements with a hydrophone were carried out in order to confirm the creation of a focalization line. An ex-vivo study using human excised veins was realized using high resolution MRI temperature control in order measure efficiency and security parameters. The second part is a study of a sector switching probe for prostate cancer treatment. The method used by Ablatherm was compared with the sector switching method, by alternating the two sectors of the probe. Results show that the lesion shape and the dimensions are the same for the two methods, but the time saving is 20% for the sector switching probe. A dynamic focalization probe for the prostate cancer treatment was studied for the last experimental part. In vitro and in vivo validation was carried out. Focal points at several distances (between 32 mm and 69 mm with respect to the probe) were obtained and sequences describing lines, splits and volumes were tested. The temperature and thermal dose maps show that the sonication strategy is adequate for inducing a homogenous lethal dose of the desired form. A treatment better adapted to the anatomy of each patient can be performed with this technique. The MRI allowed us to measure in a non-invasive manner and in real time the temperature within tissues subject to ultrasonic shooting and to visualize both the ablated volume and the adjacent tissues
18

Optical probing of thermodynamic parameters and radical production in cavitating micro-flows / Mesure optique de paramètres thermodynamiques et production de radicaux dans des micro-écoulements cavitants

Podbevsek, Darjan 18 October 2018 (has links)
Une zone de constriction dans un micro-canal fluidique peut générer, si le débit est suffisant, un écoulement bi-phasique. Ceci est l’origine de la cavitation hydrodynamique. Les échanges de chaleur latente générés par l’apparition et l’implosion des bulles impliquent une variabilité importante de la température dans les zones au-delà de la constriction. En ajoutant des sondes de température nanométriques dans le fluide et en utilisant un microscope confocal on peut déterminer la température en un point. Ainsi on a pu établir des cartographies thermiques en 2 et 3 dimensions à l’intérieur d’un écoulement stationnaire bi-phasique. La technique permet en outre d’avoir accès à la quantité de gaz ce qui permet de corréler les gradients de température avec les zones de transitions de phases. Des zones de très forts refroidissements sont observées après la constriction, là où les bulles apparaissent. Par contre on n’observe pas les zones d’échauffement attendu à cause de la condensation. Une méthode complémentaire, moins sensible, utilisant la spectroscopie Raman a aussi été utilisée pour confirmer ce résultat. Par ailleurs une nouvelle classe de matériaux luminescents sensible à la température et la pression a été étudiée. Enfin une étude de la production de radicaux lors de l’implosion des bulles a été menée en utilisant la chimiluminescence du luminol. La technique utilisée par comptage de photons a permis de quantifier cette production et une cartographie de l’émission du luminol a permis d’associer celle-ci avec la zone d’implosion des bulles / A constriction in the microchannel can be used to establish a two-phase flow, when a sufficient liquid flux is introduced. This is known as hydrodynamic cavitation. The latent heat resulting from the growing and collapsing vapor bubbles makes it interesting to observe the temperature conditions in the flow downstream of the constriction. Using fluorescence microscopy, with the addition of temperature sensitive nano probes into the working fluid, we can determine the temperature at a single point, averaged over the integration time. Coupled with a confocal microscope, we were able to produce two and three dimensional temperature maps of the steady state flow in the microchannel by the use of ratiometric intensity measurements. This technic allows us to observe temperature gradients in two-phase flow as well yielding the void fraction information. Areas of substantial cooling are observed downstream the constriction in the two-phase flow, linked to the bubble growth, while heating regions due to condensations are missing. A complementary, yet less sensitive probe-less technique using the inherent Raman scattering signal of the liquid, was used to confirm the findings. A separate study evaluating a new group of luminescent materials for optical temperature and pressure probes is performed and discussed herein. Finally, the luminol chemiluminescent reaction with radicals produced by the cavitating flow, is used to obtain a corresponding photon yield. By counting the photons produced, an estimate on the radical yield can be obtained. Additionally, rudimentary mapping of the chemiluminescence signal allows the localization of the bubble collapse regions
19

Convection turbulente dans une cellule de Rayleigh-Bénard cryogénique : de nouveaux éléments en faveur du Régime Ultime de Kraichnan

Gauthier, Frédéric 08 December 2008 (has links) (PDF)
Cette thèse est consacrée à l'étude de la convection turbulente pour des nombres de Rayleigh (Ra) pouvant atteindre 10^14 grâce à l'utilisation de l'hélium cryogénique. Nous nous intéressons plus particulièrement au régime de convection apparaissant pour Ra≈10^12. Ce régime a été observé et interprété à Grenoble il y a une dizaine d'années, comme la transition vers le Régime Ultime de la convection prédit par R. Kraichnan en 1962. Deux signatures de ce régime avaient alors été observées : une augmentation du nombre de Nusselt (Nu) ainsi qu'un changement qualitatif sur les fluctuations de température dans le cœur de la cellule, cette dernière signature ayant été contestée en invoquant un effet de taille de capteurs. Dans un premier temps, nous confirmons la transition déjà observée sur les mesures locales de température, à partir de mesures réalisées avec un thermomètre dix fois plus petit. Ce résultat est complété par une étude de l'influence de la taille des thermomètres sur les mesures. Des thermomètres dont la taille varie de 17 microns à 2 mm ont été fabriqués dans ce but. Ensuite, nous observons indirectement une instabilité de la couche limite thermique, en accord avec les prédictions sur le Régime Ultime. Cette observation est réalisée à partir de mesures des fluctuations de température de la plaque inférieure de la cellule. Cette transition et celle sur Nu interviennent pour le même Ra. Enfin, nous écartons l'hypothèse selon laquelle la transition observée sur le transfert thermique serait associée à une transition de l'écoulement à grande échelle dans la cellule, grâce à une caractérisation de cet écoulement avant et après la transition.
20

Mesure de la constante de Boltzmann par spectroscopie laser : vers une contribution au futur Système International d'unités

Lemarchand, Cyril 13 July 2012 (has links) (PDF)
Ce manuscrit présente l'expérience développée dans l'équipe MMTF du Laboratoire de Physique des Lasers avec pour objectif de contribuer à la redéfinition du Système International d'unités en mesurant la constante de Boltzmann, kB, par spectroscopie laser. La méthode utilisée est fondée sur la spectroscopie d'absorption linéaire d'un gaz d'ammoniac maintenu à température constante. La constante de Boltzmann est déduite de la mesure de température du gaz et de la largeur du profil d'absorption enregistré. Des expériences de 1ère et 2ème génération ont d'ores et déjà permis d'atteindre une incertitude statistique de 38x10-6 sur la mesure de kB. Dans ce mémoire, nous décrivons les améliorations apportées au dispositif expérimental pour réduire l'incertitude de mesure au niveau de quelques 10-6. Nous mettons à profit ces développements expérimentaux et utilisons une nouvelle procédure d'ajustement des données expérimentales pour réduire l'incertitude statistique de mesure au niveau de 6,4x10-6. Nous effectuons par la suite une étude complète des effets systématiques susceptibles d'affecter la mesure de kB. Nous décrivons notamment le dispositif expérimental mis en place pour analyser la structure hyperfine de NH3. Nous évaluons entre autres l'impact de la composition du gaz, de la saturation de la transition, et de la modulation du faisceau laser. Enfin, nous menons une étude poussée de la modélisation des collisions entre molécules. Au final, le budget d'incertitude global sur les effets systématiques est réduit au niveau de 2,1x10-6. L'ensemble des résultats obtenus et les perspectives envisagées ouvrent la voie vers une mesure optique de kB avec une incertitude de quelques 10-6.

Page generated in 0.0802 seconds