• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 76
  • 41
  • 34
  • 33
  • 15
  • 8
  • 6
  • 6
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 618
  • 618
  • 211
  • 157
  • 156
  • 116
  • 84
  • 81
  • 77
  • 64
  • 58
  • 53
  • 53
  • 47
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
441

Interpretação dos resultados de ensaios TDR para a determinação do teor de umidade dos solos / Interpretation of TDR test results for determining the moisture content of soil

Victor Jack Valdivia Calderón 20 April 2010 (has links)
Este trabalho de pesquisa apresenta uma nova abordagem para calibrar uma sonda helicoidal TDR, usada para medir o teor de umidade do solo. Foi empregada uma aproximação tomando em consideração a interpretação física dos valores de constantes dielétricas. As equações de calibração foram determinadas mediante um modelo dielétrico misto, quais relacionam a constante dielétrica da mistura multifase com a constante dielétrica e frações de volumes dessas componentes. Ensaios realizados em laboratório permitirem o desenvolvimento de duas equações de calibração para a avaliação de teor de umidade volumétrico e gravimétrico dos solos. A calibração foi executada com medições de constante dielétrica em diferentes líquidos e solos, usando uma sonda convencional TDR e a sonda helicoidal TDR. As leituras realizadas com as duas sondas foram depois comparadas. O modelo dielétrico das duas fases permitiu descrever a contribuição dos materiais dielétricos do corpo da sonda helicoidal e os materiais investigados. Mostrou-se que o conhecimento das características físicas e geométricas da sonda TDR usada nos ensaios é de crucial para garantir a qualidade das constantes dielétricas lidas, e conseqüentemente a determinação do teor de umidade in situ. / The objective of this work was to calibrate a coiled TDR probe used to measure the water content of soil. It was used an approach that takes into account a physical interpretation of the values of the dielectric constants. The calibration equations were determined by means of a mixed dielectric model, which relates the dielectric constant of a multi-phase mixture with the dielectric constants and volume fractions of its components. Tests carried out in the laboratory allowed development of two calibration equations for the assessment of the volumetric and gravimetric soil water content. Calibration was performed with measurements of dielectric constants in different liquids and soils, using a conventional TDR probe and a coiled TDR. The readings performed with the two probes were then compared. The dielectric model of two phases permitted describing the contribution of the dielectric material of the body of the probe coil and the materials investigated. It has been shown that knowledge of the physical and geometrical characteristics of the TDR probe used in the tests is crucial for the quality of the dielectric constant readings, and consequently the determination of water content in situ.
442

Analise no dominio do tempo de estruturas eletromagneticas utilizando elementos finitos vetoriais e ortogonais / Time-domain analysis of electromagnetic structures using vectorial and orthogonal finite elements

Gonçalves, Marcos Sérgio, 1973- 27 February 2007 (has links)
Orientadores: Aldario Chrestani Bordonalli, Hugo Enrique Hernandez Figueroa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-09T17:10:22Z (GMT). No. of bitstreams: 1 Goncalves_MarcosSergio_D.pdf: 5511725 bytes, checksum: 912286218aecf274afdc63d4eb68d0b5 (MD5) Previous issue date: 2007 / Resumo: Este trabalho apresenta uma nova formulação para a simulação da propagação de campos eletromagnéticos no domínio do tempo em duas e três dimensões. Os algoritmos desenvolvidos incorporam a discretização por elementos finitos e usam as funções de base de arestas ortogonais em duas e, pela primeira vez, em três dimensões para descrever o comportamento de propagação dos campos elétrico e magnético em diferentes estruturas. Tais funções são baseadas nos elementos de arestas de Whitney e preservam as mesmas características que as funções de bases de arestas convencionais. Com o uso destas funções de bases, obtêm-se, naturalmente, matrizes massas diagonais, eliminando-se, por completo, a resolução, a cada passo temporal, do sistema matricial resultante dos métodos convencionais, resultando em um alto desempenho no processamento de dados. Os campos são analisados no domínio do tempo através do método da envoltória, modelado pela equação de onda vetorial, sendo a principal aplicação o estudo de componentes fotônicos / Abstract: This work presents a new approach for the simulation of the time-domain electromagnetic fields in two and three dimensions. The developed algorithms incorporate finite-element discretization and make use of two- and three-dimension orthogonal edge basis functions to describe the electric and magnetic fields. Such functions are based on the Whitney¿s edge elements and preserve the same characteristics as those of the conventional edge basis functions. With the use of these basis functions, solution of diagonal mass matrices appear naturally, eliminating, at each time step, the matrix equations that result from conventional methods and producing a high performance data processing. The fields are analyzed in time-domain using the slow-wave method, modeled by the vector wave equation. The study of photonic components is the main application of this method / Doutorado / Telecomunicações e Telemática / Doutor em Engenharia Elétrica
443

Desempenho do reflectômetro no domínio do tempo na detecção de variações de umidade do solo. / Performance of a time domain reflectometer in the detection of soil moisture variations.

Gilberto Oliveira Joaquim Júnior 21 July 2003 (has links)
O objetivo do trabalho foi avaliar o desempenho do reflectômetro no domínio do tempo (TDR) comparativamente ao tensiômetro com manômetro de mercúrio (considerado como instrumento padrão), dando-se ênfase na sensibilidade de detecção de variações na umidade do solo sob condições de molhamento e secagem. Foi instalado um experimento em um solo classificado como Nitossolo Vermelho distrófico latossólico de textura muito argilosa, localizado próximo ao Posto Meteorológico do Departamento de Ciências Exatas, ESALQ/USP, Piracicaba (SP), Brasil, 22 o 42’ 30’’ de latitude sul e 47 o 38’ 00’’ de longitude oeste. Com dados de um ensaio de determinação da condutividade hidráulica do solo pelo Método do Perfil Instantâneo, de um período de secagem e de inundações intermitentes do solo, analisou-se a concordância entre a constante dielétrica obtido pelo TDR e o potencial matricial da água no solo obtido pelo tensiômetro, além dos valores de umidade volumétrica obtidos pelas mesmas técnicas. Concluiu-se que o desempenho do TDR foi superior ao do tensiômetro sob condições de secagem do solo e na detecção de variações de umidade. / The performance of a time domain-reflectometer (TDR) was compared with a mercury tensiometer (considered to be the norm), emphasizing the detection of variations in soil water content under wetting and drying conditions (as in instantaneous profile method to determine soil hydraulic conductivity). An experiment was performed in a Nitossolo Vermelho distrófico latossólico argiloso (Brazilian classification system), close to the meteorological observatory of the ESALQ/USP, Piracicaba (SP), Brazil, latitude 22 o 42’30’’ S, longitude 47 o 38’00’’ W. Data of matric potential, dieletric constant and water content during a dry period and water application were analyzed. The TDR cable tester was better than the tensiometer to detect the soil moisture variation.
444

Estudo da distribuição da solução no solo aplicado por gotejamento enterrado e superficial / Soil solution distribution study applied by subsurface and surface drip irrigation

Allan Cunha Barros 16 January 2008 (has links)
Em função do número reduzido de estudos sobre o movimento da água e de íons no bulbo molhado, foi realizado este trabalho com o objetivo de avaliar a distribuição de água e concentração de nutrientes no bulbo formado pelo sistema de gotejamento enterrado em comparação ao superficial. O ensaio foi conduzido na área experimental do Departamento de Engenharia Rural da Escola Superior de Agricultura "Luiz de Queiroz" - ESALQ/USP, localizada no município de Piracicaba, SP. Para a avaliação foram abertas trincheiras e instaladas sondas de TDR, para o monitoramento da distribuição da solução, dispostas a 0,5; 0,15; 0,25; 0,35 e 0,45 m - profundidade, e a 0,5; 0,15; 0,25; 0,35 m - comprimento, totalizando 17 sondas em malha por trincheira. A solução de KNO3 foi aplicada a partir de gotejadores com diferentes vazões (2 e 4 L/h), sendo aplicado o volume de 1 L em intervalos de 1 hora, totalizando 10 L de solução por repetição, Conjuntamente ao monitoramento da distribuição da solução no solo, medições da área superficial molhada e do disco saturado foram feitas com régua milimetrada, além disso, foi estabelecido um volume de controle onde foram avaliadas a uniformidade de aplicação de água e KNO3. Desta forma, foi possível verificar que: em relação aos sistemas superficiais, os sistemas enterrados apresentaram menor área superficial molhada e atingiram uma maior largura e profundidade; a umidade inicial do solo influencia a formação do bulbo molhado e o movimento do KNO3 no solo; a uniformidade de sais distribuídos no volume de controle é afetada negativamente pelo aumento do volume aplicado e as maiores concentrações de água e concentração de KNO3 foram obtidas próximas ao ponto de emissão. / In function of the reduced number of studies on the water and ions movement in the wet soil volume, this work was conducted with the goal of evaluating the distribution of water and nutrient concentration in the wetted soil volume formed by subsurface drip irrigation (SDI) in comparison to surface system. The rehearsal was concducted in the experimental area of the Rural Engineering Department - ESALQ/USP, located in Piracicaba, SP. Trenches were opened and installed probes of TDR for studying to solution distribution, to facilitate the study a mesh of probes was disposed to 0,5; 0,15; 0,25; 0,35 and 0,45 m - depth, and to 0,5; 0,15; 0,25; 0,35 m - length, with the total of 17 probes. The solution of KNO3 was applied starting from emitters with different flows (2 and 4 L/h), it was applied the volume of 1 L within intervals of 1 hour, with the total of 10 L of solution for repetition. All together to study the solution distribution in the soil, the wet superficial area measurements and of the saturated disc they were done by the ruler, besides, it was established a control volume where the uniformity application of water and KNO3 was analysed. This way, it was possible to verify that: in relation to the superface systems, the SDI presented smaller wet superficial area and they reached a larger width and depth; the initial soil water content influences the formation of the wetted soil volume and the KNO3 movement in the soil; the salt uniformity, distributed in the control volume, is affected negatively by the applied volume increased, and the largest concentrations of water and KNO3 were obtained close to the emission point.
445

Avaliação de uma sonda TDR helicoidal para a estimativa do teor de umidade de solos em campo e laboratório / Evaluation of a helicoidal TDR probe to estimate the soil water content in laboratory and in situ

Cleber Decarli de Assis 09 May 2008 (has links)
Este trabalho de pesquisa apresenta a avaliação de uma sonda TDR helicoidal para estimar o teor de umidade dos solos, em diferentes profundidades, através da técnica da reflectometria no domínio do tempo (TDR). Essa sonda, desenvolvida especificamente para esse fim, foi devidamente calibrada em laboratório para diferentes tipos de solo. O processo de calibração consistiu na determinação da constante dielétrica aparente (Ka) e condutividade elétrica volumétrica (ECb) de um mesmo solo com diferentes teores de umidade. Posteriormente foram buscadas correlações entre Ka e o teor de umidade gravimétrico (w), obtido em estufa. São propostas correlações entre w e Ka, entre w e \'KA POT. 1/2\' e entre teor de umidade volumétrico (\'teta\') e Ka. Também foram consideradas as correlações propostas por Yu e Drnevich (2004), visando estimar também a massa específica seca dos solos. Foram realizados ensaios de campo para a validação das equações de calibração. Os valores dos teores de umidade estimados através da técnica da reflectometria no domínio do tempo, tanto em laboratório como em campo, foram comparados com os valores de teor de umidade obtidos com o método da estufa. Com base nos resultados foram determinados os erros referentes às calibrações. Nos ensaios de campo, os teores de umidade obtidos através da correlação entre w e \'KA POT. 1/2\' apresentaram melhores resultados, quando comparados com aqueles estimados com as outras correlações. Pelos resultados obtidos conclui-se que a técnica TDR é uma alternativa viável para a estimativa em campo do teor de umidade em grandes profundidades. / In this work is presented the evaluation of a recently developed helicoidal probe used for estimating the soil water content through the time domain technology (TDR). This probe has been calibrated in laboratory for different types of soils. The calibration process consisted in assessing the values of the apparent dielectric constant (Ka) and the bulk electric conductivity (ECb) of a specific soil at different levels of water content (w). Subsequently, correlations between the apparent dielectric constant and the water content have been established. The same has done with the bulk electric conductivity. Correlations between Ka and w, \'KA POT. 1/2\' and w, \'teta\' (volumetric water content) and Ka have been proposed. Also, the correlations proposed by Yu and Drnevich (2004) have been considered. To validate the proposed correlations, tests using the helicoidal probe were performed in the field. Estimated values of field water content, using the TDR technology have been compared to the correspondent oven water content values. Based on these comparisons, errors regarding the calibrations have been calculated. In the field tests, the correlations between \'KA POT. 1/2\' and w have presented more accurate results than those obtained with the other correlations. Experimental results have shown that the TDR technology for estimating water content at different depths in the field is feasible and expedite.
446

Simulação híbrida no domínio do tempo de transitórios eletromecânicos e eletromagnéticos: integração de um aerogerador de indução duplamente excitado

Theodoro, Thainan Santos 05 September 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-25T14:57:44Z No. of bitstreams: 1 thainansantostheodoro.pdf: 6277443 bytes, checksum: 64fdae570574b42d13c86c42cedaca9e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-25T15:29:25Z (GMT) No. of bitstreams: 1 thainansantostheodoro.pdf: 6277443 bytes, checksum: 64fdae570574b42d13c86c42cedaca9e (MD5) / Made available in DSpace on 2017-04-25T15:29:25Z (GMT). No. of bitstreams: 1 thainansantostheodoro.pdf: 6277443 bytes, checksum: 64fdae570574b42d13c86c42cedaca9e (MD5) Previous issue date: 2016-09-05 / Esta dissertação apresenta uma técnica de simulação híbrida no domínio do tempo de programas de transitórios eletromecânicos e eletromagnéticos usando o MatLab/ Simulink, a qual confere eficiência computacional e precisão, tanto na análise de sistemas de potência, quanto de controle, sobretudo em situações nas quais fenômenos eletromagnéticos e eletromecânicos se sobrepõe, como é o caso da integração de grandes parques eólicos. Para que ocorra a interação entre os dois programas é necessário a adequação das grandezas de fasores para formas de onda e vice versa, assim, é apresentada uma nova abordagem de extração de fasores instantâneos a partir do DSOGI com boa eficiência computacional com perda desprezível de informações. A comunicação regular entre os programas é feita através do protocolo de comunicação baseado na plataforma TCP/IP, que possibilita a representação de modelos distribuídos e a divisão do esforço computacional. São apresentados resultados de simulação para a integração de um parque eólico, representado por um aerogerador DFIG, à uma rede de 29 barras e 7 geradores. Todo o sistema foi representado em um programa de transitórios eletromagnéticos para comparação com os resultados do programa híbrido. Os resultados se mostraram encorajadores já que houve diminuição de quase 70% do tempo de processamento. / This dissertation presents a hybrid simulation technique in the time domain of electromechanical and electromagnetic transient programs using the MatLab/Simulink, which confers computational efficiency and precision, in both power system and control analysis, mainly in situations where electromagnetic and electromechanical phenomena overlap, such as the integration of large wind farms. In order to guarantee the interaction between the two programs it is necessary to adapt the phasor magnitudes to waveforms and vice versa, thus, a new approach is presented for the extraction of instantaneous phasors using the DSOGI approach, with good computational efficiency and negligible loss of information. The regular communication between the programs is done through the communication protocol based on the TCP/IP platform, which allows the representation of distributed models and enables the division of computational effortt between computers. Simulation results are presented for the integration of a wind farm, represented by a DFIG, to a network of 29 bars and 7 generators. The entire system was represented in an electromagnetic transient program for comparison with the results of the hybrid program. The results were encouraging since there was a decrease of almost 70 % of the processing time.
447

Irrigação da cana-de-açúcar com esgoto tratado por gotejamento subsuperficial / Sugarcane production using treated sewage applied by subsurface drip irrigation

Santos, Leonardo Nazário Silva dos, 1984- 25 August 2018 (has links)
Orientadores: Edson Eiji Matsura, Regina Célia de Matos Pires / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-25T22:38:01Z (GMT). No. of bitstreams: 1 Santos_LeonardoNazarioSilvados_D.pdf: 9014714 bytes, checksum: 443fd6aa43099fa45fe1a9d094fc9afb (MD5) Previous issue date: 2014 / Resumo: A agricultura irrigada é a atividade caracterizada pelo alto consumo de água. Nesse contexto, a utilização de efluente de esgoto tratado (EET) como fonte de água para a irrigação pode ser uma alternativa para substituição de água doce, mas que requer estudos específicos para adoção e uso de forma sustentável. Assim, objetivou-se avaliar os efeitos da aplicação de EET via gotejamento subsuperficial sobre as propriedades físicas do solo (Latossolo Vermelho distroférrico), distribuição da umidade no perfil do solo, desenvolvimento do sistema radicular, a produção de colmos e a qualidade tecnológica do caldo da cana-de-açúcar (Saccharum officinarum L.). O experimento foi instalado em Campinas-SP, Brasil, adotando-se delineamento em blocos casualizados em esquema fatorial 2x2x2+1, com cinco repetições. Os fatores estudados foram: duas profundidades de instalação do tubo gotejador (0,2 e 0,4 m); duas qualidades de água (efluente de esgoto tratado ¿ EET, e água de reservatório superficial ¿ ARS); complementação nutricional via fertirrigação (com complementação nutricional ¿ CN, e sem complementação nutricional ¿ SN); e a testemunha sem irrigação. Para avaliação da umidade no perfil do solo foi utilizada a técnica da TDR (Time Domain Reflectometry); para a avaliação radicular foi utilizado o sistema minirhizotron; para determinar os atributos físicos do solo foram utilizadas amostras deformadas e indeformadas; e a produtividade estimada por biometria. O uso de efluente de esgoto tratado como fonte hídrica na irrigação demonstrou ser opção sustentável do ponto de vista agronômico, proporcionando incrementos na produtividade e melhoria na qualidade tecnológica da cana-de-açúcar em relação ao tratamento sem irrigação. A instalação do tubo gotejador a 0,2 m de profundidade disponibilizou água na região de maior desenvolvimento radicular e reduziu as perdas de água por evaporação e por percolação profunda. Os fatores testados não alteraram significativamente os parâmetros sódico-salinos, as propriedades físicas do solo e o comprimento radicular da cana-de-açúcar / Abstract: Irrigated agriculture is characterized by higher water consumption. In this context, the use of treated sewage effluent (TSE) as a water resource for irrigation can be an alternative in replacing freshwater, however it requires specific studies for adoption and as well as for sustainable use. Therefore, this study aimed to evaluate the TSE subsurface drip irrigation effect on a dystrophic Red Latossolo (Oxisol) physical properties, the effect on the moisture distribution in the soil profile, on the root system development, as well as on the yielding and quality of produced sugarcane (Saccharum officinarum L.). The experiment was carried out in Campinas-SP, Brazil, adopting a randomized block design in a 2x2x2+1 factorial, with five replications. Studied factors included: two depths of the dripline (0.2 to 0.4 m); two water qualities (treated sewage effluent ¿ TSE, and surface reservoir water ¿ SRW); nutritional supplementation by fertigation (with nutritional supplementation ¿ NS, and without nutritional supplementation - WNS); and no irrigation (NI). To evaluate the moisture in the soil profile it was used the technique named TDR (Time Domain Reflectometry); to evaluate root development was used the system known as minirhizotron; to determine soil physical properties it was employed disturbed and undisturbed samples; and productivity estimated by biometrics. The use of treated sewage effluent as a water resource for irrigation proved to be a sustainable option through the agronomic point of view, providing productivity increases and improvement of technological quality of sugarcane compared to treatment without irrigation. The installation of the dripline to 0.2 m depth provided of water in the region highest root development and reduced water losses by evaporation and deep percolation. The tested factors did not significantly alter the sodic-saline parameters, the physical properties of soil and root length of sugarcane / Doutorado / Agua e Solo / Doutor em Engenharia Agrícola
448

Influência da molhabilidade de rochas na recuperação avançada de petróleo : um estudo por RMN / Influence of rocks wettability in enhanced oil recovery : a study by NMR

Ungarato, Rafael Fernando De Santi, 1988- 02 April 2013 (has links)
Orientador: Edvaldo Sabadini / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T20:35:03Z (GMT). No. of bitstreams: 1 Ungarato_RafaelFernandoDeSanti_M.pdf: 3937275 bytes, checksum: bb5e422a60e0f90e98a552f1ea02db61 (MD5) Previous issue date: 2013 / Resumo: O estudo de soluções para métodos especiais de recuperação de petróleo vem sendo amplamente utilizado, principalmente devido à grande quantidade de óleo remanescente nos reservatórios após as recuperações primária e secundária. Soluções consideradas de potencial recuperador devem possuir algumas características específicas como uma baixa tensão interfacial água/óleo e viscosidade moderada, de modo a melhorar a eficiência do petróleo varrido. Interações fluidos-rocha e óleo-rocha são determinantes no montante de óleo a ser recuperado, assim sendo, estudos com relação à molhabilidade das superfícies das rochas mostram-se fundamentais. Um método de análise largamente empregado e considerado como padrão para medidas de molhabilidade é o teste de Amott, porém, tal método apresenta grande tempo de análise e preparo de amostra. O presente trabalho analisa a molhabilidade de rochas utilizando-se a técnica de Ressonância Magnética Nuclear de Baixo Campo. Ela se baseia nos tempos de relaxação da magnetização das populações de água e óleo, livres ou ligadas na superfície da rocha, permitindo de maneira rápida, a determinação da quantidade de óleo removida. Nesse estudo foram analisadas amostras de arenito e carbonato, caracterizando-as comparativamente com relação ao tamanho e homogeneidade dos poros por dados de RMN. As rochas foram impregnadas com petróleo e deixadas em contato com diferentes soluções de surfactantes (não iônico e zwiteriônico), sendo possível a análise quanto à diferença de molhabilidade entre as mesmas. Com relação a essas soluções, foram utilizados diversos surfactantes, com diferenças quanto aos grupos funcionais, ao tamanho da cadeia hidrofóbica, a presença de uma ou duas dessas cadeias e em diferentes concentrações, sendo possível a obtenção de informações relacionadas à eficiência de extração de óleo para cada uma delas. Observou-se que a técnica utilizada apresentou excelentes resultados, permitindo diferenciar a capacidade de extração para cada solução estudada / Abstract: The study of solutions to enhance oil recovery has been widely used, mainly due to large amount of oil that remains in reservoirs after primary and secondary recoveries. Solutions with good potential to recovery must have some specific characteristics such as low water/oil interfacial tension and a moderate viscosity to improve the efficiency of the oil swept. The fluid-rock and oil-rock interactions are of great importance concerning the total oil recovered. Therefore, studies involving wettability of rock surfaces are essential. A traditional method of analysis, which is considered as standard to measures the wettability is the Amott test, however, this method spends too much time and sample preparation. This study analyzes rock wettability using the technique of Low Field Nuclear Magnetic Resonance (low-field NMR). This is based on the relaxation rates of the magnetization of water and/or oil molecules, free or bounded at the surface of the pores of the rock. The technique allows a quick determination of the amount of oil removed. In the present study, the size and pores homogeneity of sandstone and carbonate were analyzed using low field-NMR. The rocks were impregnated with oil and then left in contact with different solutions of surfactants (non-ionic and zwitterionic), being possible to analyze the differences in wettability among them. Several concentrations of surfactants, in which differences in their: functional groups, hydrophobic chain length and number of chains, were studied. The NMR technique revealed excellent results, providing information related to the efficiency of oil extraction for each studied solution / Mestrado / Físico-Química / Mestre em Química
449

Resposta temporal de vigas com vibro-impacto utilizando modelos de força de contato / Time response of beams with vibro-impact using contact force models

Ferreira, Luan Jose Franchini, 1987- 22 August 2018 (has links)
Orientador: Alberto Luiz Serpa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-22T21:32:28Z (GMT). No. of bitstreams: 1 Ferreira_LuanJoseFranchini_M.pdf: 31334961 bytes, checksum: 0c668b476e8b23fc3d0c578acdda9020 (MD5) Previous issue date: 2013 / Resumo: O vibro-impacto de vigas ocorre devido ao contato intermitente das estruturas na presença de folgas, gerando desgaste excessivo, vibração com grandes amplitudes, falhas prematuras de componentes e altos níveis de ruído. A determinação da resposta no domínio do tempo do sistema, ou seja, deslocamentos, velocidades e acelerações, juntamente com os esforços de contato são de fundamental importância para o projeto desses sistemas, na prevenção de falhas e no controle de vibrações e ruído. Foi desenvolvido um código utilizando a linguagem MATLAB que a partir dos dados de uma malha de elementos finitos de viga, determina a resposta dinâmica da viga sobre a condição de vibro-impacto. A resposta dinâmica foi obtida utilizando a integração numérica da equação do movimento discretizada. Os métodos de integração numérica da diferença centrada, Newmark e alpha-HHT foram implementados para o caso de contato intermitente e utilizados na determinação da resposta dinâmica da estrutura. A condição de contato intermitente originada pelo processo de vibro-impacto foi tratada avaliando a condição de não penetração dos corpos nos instantes de tempo específicos definidos pelo intervalo de tempo utilizado na integração numérica. Os modelos de contato mecânico utilizados foram os modelos de força de contato proporcional e o cúbico / Abstract: The vibro-impact of beams occurs due to intermittent contact of the structures in the presence of clearances, generating excessive wear, vibration with large amplitudes, premature failure of components and high noise level. A MATLAB code was developed using the finite element model of the beam, obtaining the dynamic response of the beam with the vibro-impact condition. The dynamic response was obtained using numerical integration of the discretized equation of motion. The numerical integration method of the central difference, Newmark and alpha-HHT were implemented for the case of contact and used for the determination of the structure time response. The contact condition caused by vibro-impact process was treated evaluating the condition of nonpenetration bodies in specific instants of time defined by the numerical integration method. The mechanical contact models proportional force and cubic force were used / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
450

Utilização de linhas de transmissão semelhantes no ensaio de energização de um tronco com pouco mais de meio comprimento de onda / Utilization of similar transmission lines on energization test of a trunk with a little more than a half-wavelength

Gomes, Elson Costa, 1986- 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T21:10:18Z (GMT). No. of bitstreams: 1 Gomes_ElsonCosta_M.pdf: 4986234 bytes, checksum: 3e2729d9cbec861f21c958f84db0b17e (MD5) Previous issue date: 2012 / Resumo: O transporte de grandes blocos de energia elétrica através de longas distâncias que variam de 2500 a 3000 km impõe a utilização de soluções mais adequadas baseadas em linhas de transmissão não convencionais. Uma alternativa em corrente alternada (CA) é a linha com pouco mais de meio comprimento de onda, que para o caso brasileiro, cuja frequência industrial é 60 Hz, apresenta comprimento físico de aproximadamente 2600 km. Por não existir no mundo um sistema similar em operação, foi proposta a realização da manobra de energização de um Elo CA Teste composto pela conexão em série de três interligações do sistema brasileiro que têm características elétricas semelhantes e que juntas formam um tronco de 2600 km. O presente trabalho visa avaliar a adequação de se utilizar um tronco formado por linhas semelhantes para representar um tronco de um pouco mais de meio comprimento de onda durante a manobra de energização da linha em vazio. Através de análise da resposta dos parâmetros das linhas no domínio da frequência e de simulações no domínio do tempo realizadas com os programas computacionais ATP e PSCAD/EMTDC para a avaliação de transitórios, observou-se que o uso do tronco proposto para o ensaio de energização é adequado e foram determinados valores limites para as diferenças entre características elétricas das linhas que podem compor sistemas com pouco mais de meio comprimento de onda, fornecendo importantes subsídios para a possível realização do referido ensaio em outros locais do mundo / Abstract: The transportation of large blocks of energy through very long distances between 2500 and 3000 km requires an extensive research for the best solutions based on non-conventional transmission systems. A very interesting alternative is the AC transmission with a little more than half-wavelength, which corresponds to a transmission line of 2600 km in systems like the Brazilian, with 60 Hz fundamental frequency. However, as there is no similar system in operation around the world, it was proposed a realization of the energization of an AC-Link Test composed of three interconnection trunks that have similar electrical characteristics that together can form a trunk of 2600 km. In this work it is evaluated the adequacy of using a trunk formed by similar lines to represent a line of a little more than a half wave-length during an energization maneuver. The response of AC-Link Test parameters in frequency domain and time domains simulations performed with the computer programs ATP and PSCAD/EMTDC, to evaluate transient response, showed that the proposed use of the trunk for the energization is appropriate. It was also identified limits for the differences between electrical characteristics of the lines that can form a trunk with a little more than a half-wavelength, contributing to the possible realization of the same test in other parts of the world / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Page generated in 0.3611 seconds