• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 155
  • 18
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 175
  • 87
  • 84
  • 81
  • 57
  • 45
  • 44
  • 43
  • 34
  • 28
  • 26
  • 25
  • 25
  • 25
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Relação da expressão do tlr-2, da enzima iNOS, das citocinas IL-10, TNF-α e TGF-β com a carga parasitária da pele de cães naturalmente acometidos por leishmaniose visceral: Dandara Camila Morais Pereira. -

Pereira, Dandara Camila Morais [UNESP] 13 August 2015 (has links) (PDF)
Made available in DSpace on 2016-05-17T16:51:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-13. Added 1 bitstream(s) on 2016-05-17T16:54:16Z : No. of bitstreams: 1 000864272_20160704.pdf: 706780 bytes, checksum: 4d6888c37d677fae1dd7bf418a013985 (MD5) Bitstreams deleted on 2016-07-25T13:17:41Z: 000864272_20160704.pdf,. Added 1 bitstream(s) on 2016-07-25T13:18:48Z : No. of bitstreams: 1 000864272.pdf: 941126 bytes, checksum: 0602961cda7c25695afee5dc324562ba (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / The progression of the canine visceral leishmaniasis (CVL) is related to the immune response profile. The effective cellular immunity is related to the predominance of Th1 cytokines such as TNF-α and the disease is related to an exacerbated humoral immune response, with the predominance of Th2 cytokines such as IL-10 and TGF-β. TLR-2 is an important receptor of the innate immunity involved in the induction of the cytokines production and the activation of iNOS in visceral leishmaniasis. To understand how the skin may become a permissive microenvironment for the multiplication of this parasite, the expression of genes encoding to TLR-2, to the iNOS enzyme and to the cytokines IL-10, TNF-α and TGF-β was evaluated in skin of dogs naturally affected by CVL and were then was related to the parasite load of this tissue. We observed that the skin of dogs naturally affected by visceral leishmaniasis has a mixed Th1/Th2 immune response profile, with an increased expression of TLR-2, IL-10 and TNF-α that correlates to the increasing of the parasitic load in this tissue, giving these mediators an important role in the pathogenesis of CVL
112

[en] AN IMPROVED STEADY-STATE MODEL FOR TAP-CHANGING TRANSFORMER / [pt] NOVO MODELO DE TRANSFORMADOR COM TAP VARIÁVEL EM REGIME PERMANENTE

CARLOS APARECIDO FERREIRA 25 June 2013 (has links)
[pt] O fenômeno de estabilidade de tensão vem despertando grande interesse acadêmico e das principais empresas de energia elétrica do mundo desde que começou a ser observado em sistemas reais, no final da década de setenta. Sua ocorrência está relacionada ao carregamento excessivo das linhas de transmissão. Modelar transformador com tap variável adequadamente é fundamental em análises de estabilidade de tensão, tanto no que diz respeito às informações fornecidas ao operador referentes às margens de estabilidade de tensão, quanto aos efeitos de ações de controle de tensão. O modelo de transformador com tap variável utilizado mundialmente consiste de uma impedância, obtida através do ensaio em curto-circuito e com tap nominal, em série com um transformador ideal. Esta tese mostra que, em estudos de estabilidade de tensão, o uso desse modelo leva a resultados qualitativamente errados. Para demonstração, utiliza-se um circuito pequeno e os conceitos de máxima potência transmitida, impedância equivalente da carga, e efeito do controle de tensão. Propõe-se um novo modelo coerente com os resultados obtidos em laboratório, com as leis de circuitos elétricos e com a teoria de estabilidade de tensão. Esse modelo pode ser utilizado em qualquer estudo em regime permanente. Através de diversas simulações computacionais, diferenças quantitativas e principalmente qualitativas foram obtidas comparando-se os resultados dos dois modelos. / [en] The voltage stability phenomenon is of interest since it began to be observed in real systems in the late seventies. It happens due to excessive loading of transmission lines. The modeling of tap-changing transformers is fundamental in voltage stability analysis, in terms of the information provided to the operator about voltage stability margins and the effects of voltage control actions. The model for tap-changing transformers currently in widespread use consists of an impedance, measured in a short-circuit test with a nominal tap, in series with an ideal transformer. The use of this model in voltage stability studies leads to qualitatively incorrect results, as shown in this thesis. For demonstration purpose a small circuit and the concepts of maximum load, equivalent load impedance and voltage control effects are used. An improved model that takes into account laboratory results, circuit laws and voltage stability theory is proposed. This model can be used in any steady-state study. It gives results that are not only more accurate than those obtained with the conventional model, but also, as shown in this thesis, qualitatively different.
113

Bem-aventuranças: Didaqué Querigma e ensino transformador

Inês Pozzagnolo Leite 21 December 2012 (has links)
O ensino transformador de Jesus evidenciado nas bem-aventuranças é ancorado em sua ética que é ancorada em seu amor. A presente pesquisa divide-se em três capítulos respectivamente: O evangelho de Mateus e seu contexto, Bem-aventuranças e Palavração. O primeiro capítulo trata do evangelho de Mateus na tentativa de detectar, autoria, fontes, lugar, data e também a questão social na prática de Jesus. O segundo estuda as bem-aventuranças em Mateus, suas semelhanças e diferenças com Lucas e ainda, contrapõe o ensino com base no ser com a lógica capitalista do ter. O terceiro trabalha a relação existente entre a palavra e a ação na atividade pública de Jesus e tenta fazer ponte com a prática docente atual. Sob o título Bem-Aventuranças: Didaqué Querigma e Ensino Transformador, o diálogo foca no ensino a serviço do reino de Deus, em qualquer espaço ou ambiente onde quer que ele aconteça. A partir das bem-aventuranças, que visam aproximar Deus e as pessoas e concretizar a fé, fica claro o posicionamento de Jesus, é ao lado do pobre, do simples, do injustiçado, em suas muitas faces. Jesus dá ênfase ao que é fundamental, o ser humano. Portanto, a pesquisa se preocupa em trazer a dimensão prática e atual do ensino das bem-aventuranças que desejam mostrar que o reino de Deus é possível em Jesus. Ele dá novo sentido para a vida humana, apontando para o alvo onde Deus quer que cheguemos como cristãos. Muito diferente de se limitar a transferir conhecimento, Jesus mostra que a justiça e a solidariedade estão por excelência acima da lei. E que servir não se caracteriza como lei, mas como impulso a partir da graça. Nesta perspectiva, o ensino transformador terá olhos para aqueles que estão desfavorecidos e encoraja a agir contrário às estruturas injustas existentes. Move a dirigir-se a eles como a amigos, assim como Deus escolhe ser nosso amigo e quando alguém o questiona responde simplesmente EU SOU O QUE SOU. Ensinar numa perspectiva transformadora só é possível se quem ensina tiver sido transformado. Ser transformado pela Palavra de Deus é ser fiel a Jesus e ao seu ensino que convida a converter primeiro os de cima, os líderes, que precisam perceber as pessoas e ajudar. Este é o verdadeiro ensino e culto. O que fundamenta as bem-aventuranças é a ética do ser. Valores como justiça e solidariedade nascem do cristianismo, por isso o ensino numa perspectiva transformadora requer urgência em agir para mudar, melhorar situações indignas. A saber, ensinar conforme o exemplo deixado por Jesus vai além de comunicar ou transferir, implica em se importar, se preocupar com outro, com o próximo. Pois, evidentemente quanto mais próximos estivermos dos ensinos de Jesus mais humanos nos tornaremos. / The transforming teaching of Jesus demonstrated in the beatitudes is anchored in his ethics that are grounded in his love. This research is divided into three chapters: The Gospel of Matthew and its context, the Beatitudes and Jesus' attitude in harmony with his preaching. The first chapter deals with the Gospel of Matthew and seeks to detect: authorship, sources, location, date, and also the social practice of Jesus. The second studies the Beatitudes in Matthew, their similarities and differences with Luke and also confronts teaching based on being with the capitalist logic of possessing. The third chapter deals with the relationship between words and action in the public activity of Jesus and tries to relate this to the current teaching practices. Under the title, "The kerygma in transformative teaching: "ethics-teaching" of the Beatitudes, the dialogue focuses on education in the service of God's kingdom in any space or environment wherever it happens. From the Beatitudes, which aim to bring God and people closer and make faith concrete, it is clear that the position of Jesus is with the poor, the simple, the downtrodden, in their many faces: children, women, poor, sick and others. Jesus emphasizes what is essential: the human being. Therefore, this research concerned itself with bringing the practical and present dimension of the teaching of the Beatitudes that wishes to show that the kingdom of God is possible in Jesus. He gives new meaning to human life, pointing to the place where God wants Christians to come. Very different from a simple transference of knowledge, Jesus shows that justice and solidarity are completely above the law. And that service is not characterized as law but as impelled by grace. In this perspective, transformative teaching has eyes for those who are disadvantaged and encourages them to act contrary to the existing unfair structures. It moves to view them as friends just as God chooses to be our friend and when someone questions him, he answer just: "I AM THAT I AM." Teaching in a transformative perspective is only possible if the one who teaches has been transformed. Being transformed by God's Word is to be faithful to Jesus and his teaching that invites first the top leaders to be converted, those who need to understand and help people. This is true teaching and worship. What underlies the beatitudes is the ethics of being. Values such as justice and solidarity are born from Christianity, by which the transformative teaching perspective requires urgency to act for change, to improve undignified situations. Namely, teaching as the example set by Jesus goes beyond communicating or transferring, it implies caring, being concerned about others, about our neighbor. This, because obviously the closer we are to the teachings of Jesus the more human we become.
114

Plasma rico em plaquetas de equinos resfriado e criopreservado com dimetilsulfóxido e trealose / Equine platelet-rich plasma cooled and cryopreserved with dimethylsulfoxide and trehalose

Kwirant, Liomara Andressa do Amaral January 2017 (has links)
O plasma rico em plaquetas (PRP) é utilizado na medicina equina para o tratamento de lesões ósseas, articulares, tendíneas e ligamentares. No entanto o PRP deve ser preparado no momento de cada aplicação, pois seu tempo máximo de utilização após o preparo é de apenas oito horas. O objetivo deste estudo foi avaliar o resfriamento e criopreservação como métodos de armazenamento do PRP equino utilizando dois crioprotetores: dimetil sulfóxido (DMSO) e trealose, na tentativa de manter a viabilidade plaquetária após o armazenamento a baixas temperaturas. Duas amostras de PRP foram preparadas a partir da centrifugação do sangue de seis pôneis saudáveis e foram destinadas à criopreservação a -196º C ou ao resfriamento a 4º C. Cada amostra de PRP preparada foi dividida em quatro alíquotas: fresca, com DMSO, com trealose ou sem crioprotetor. As amostras frescas foram avaliadas quanto à contagem plaquetária, determinação do volume plaquetário médio (VPM), concentração plaquetária em relação ao sangue total e quantificação do fator de crescimento de transformação beta 1 (TGF-β1). As amostras criopreservadas e resfriadas ficaram armazenadas por 14 dias e foram então submetidas às mesmas análises laboratoriais. O número de plaquetas e concentração plaquetária foram similares entre as amostras frescas e resfriadas com ou sem crioprotetor, mas foram superiores nas amostras frescas em relação às amostras criopreservadas. Observou-se aumento do VPM em todas as amostras armazenadas, indicando que as plaquetas sofreram lesões durante o armazenamento. A liberação de TGF-β1 foi superior no PRP fresco em relação ao PRP resfriado ou criopreservado, não havendo diferença entre as amostras que continham ou não crioprotetores. A adição dos crioprotetores DMSO e trealose não impediu as lesões plaquetárias de armazenamento. Por outro lado, tanto as amostras resfriadas quanto as criopreservadas liberaram quantidades significativas de TGF-β1. / Platelet rich plasma (PRP) is used in equine medicine for treatment of bone, joint, tendon and ligament injuries. However the PRP must be prepared at the time of each application, since its maximum time of use after the preparation is only eight hours. The objective of this study was to evaluate cooling and cryopreservation of equine PRP as storage methods using two cryoprotectants: dimethyl sulfoxide (DMSO) and trehalose, in an attempt to maintain platelet viability after storage at low temperatures. Two PRP samples were prepared from the blood centrifugation of six healthy ponies and were intended for cryopreservation at -196 ° C or cooling at 4 ° C. Each prepared PRP sample was divided into four aliquots: fresh, DMSO, trehalose or without cryoprotectant. The fresh samples were evaluated for platelet count, determination of mean platelet volume (MVP), platelet concentration in relation to whole blood and quantification of transforming growth factor beta 1 (TGF-β1). The cryopreserved and cooled samples were stored for 14 days and then submitted to the same laboratory tests. The number of platelets and platelet concentrations were similar between fresh and cooled samples with or without cryoprotectant, but were higher in fresh samples than in cryopreserved samples. An increase in MPV was observed in all stored samples, indicating that platelets suffered lesions during storage. The release of TGF-β1 was higher in fresh PRP than in cold or cryopreserved PRP, with no difference between samples containing or not cryoprotectants. The addition of DMSO and trehalose cryoprotectants did not prevent platelet storage lesions. On the other hand, both the cooled and cryopreserved samples released significant amounts of TGF-β1.
115

Efeitos da combinação do fator de crescimento de fibroblastos básico e fator de transformação de crescimento beta na proliferação, expressão de genes para colágeno tipos I e III, metaloproteases-1 e -2 e TIMPs 1,2 e 3, e na modulação da síntese destes próprios fatores de crescimento pelas células do ligamento periodontal de humanos

Ruiz, Karina Gonzales Silvério [UNESP] 06 June 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-06-06Bitstream added on 2014-06-13T19:23:26Z : No. of bitstreams: 1 ruiz_kgs_dr_arafo.pdf: 357284 bytes, checksum: 93541a495590ca3b701f6cf9ef876131 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente estudo foi avaliar o efeito da combinação do fator de crescimento de fibroblastos básico (b-FGF) e fator de transformação de crescimento beta (TGF- beta) na proliferação, expressão de genes para colágeno tipos I e III, metaloproteases -1 e -2 e TIMPs 1, 2 e 3, e na síntese destes próprios fatores de crescimento pelas células do ligamento periodontal de humanos. A avaliação da proliferação celular foi realizada após os períodos de 24 e 48h na presença dos fatores de crescimento, através da mensuração do nível de MTS reduzido a formazan pelas células viáveis, e a síntese de b-FGF e TGF-b pelo teste ELISA empregando a técnica sandwich. Conclui-se que as associações do bFGF e do TGF-b atuaram de maneira dose-dependente no estímulo à proliferação celular, o aumento na expressão de genes para colágeno e TIMPs e redução para as metalproteases e modulação da síntese deles próprios. / The aim of this study was to evaluate the effect of association of basic fibroblast growth factor and transforming growth factor beta on the proliferation, expression of colagen type I e III, matrix metalloproteinases-1 e -2 e TIMPs 1, 2 e 3, and on the modulation of the syntheses oh these growth factors by humans periodontal ligament cells. The cellular proliferation was evaluated to 24 and 48 hours of incubation by the colorimetric method. The synthese of bFGF and TGF-ß was verificated by ELISA method, using a sandwich techinique, and mRNA expression by Real Time - PCR. In conlusion, the associations of bFGF e TGF-ß influenced of dose-dependent manner on the cellular proliferation, on the increasing of the expression to collagen and TIMPs, and on the reduction to metaloproteinases and, the modulation of these own synthesis.
116

Diferenciação osteogênica de células mesenquimais do cordão umbilical canino

Souza, Talita Floering Brêda [UNESP] 30 August 2013 (has links) (PDF)
Made available in DSpace on 2015-04-09T12:28:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-08-30Bitstream added on 2015-04-09T12:48:01Z : No. of bitstreams: 1 000814146.pdf: 660875 bytes, checksum: 9336b38c8a05d65357c828a9a2773a9b (MD5) / This study aimed to isolate MSCs from canine Wharton's jelly umbilical cord and evaluate in vitro the effect of PRP and the MOD in osteogenic differentiation of these cells in the absence of osteogenic medium. Cells were isolated and characterized as undifferentiated mesenchymal cells with a phenotype fibroblasts-like and characteristic phenotype of confirmed by flow cytometry with CD44 +, CD105 +, CD271 +, CD34-and CD45-, plus the ability to differentiate into adipocytes, chondrocytes and osteocytes. Except for the control group (MSCs), in all groups, G-PRP (PRP and MSCs), G-DBM (DBM and MSCs) and G-PRP + DBM (MSCs and PRP + DBM) was differentiation osteoblastic with production of mineralized bone matrix confirmed by Alizarin red staining. The measurement of alkaline phosphatase (AP) increased up to 14 days in all groups. Bone proteins were expressed in the polymerase chain reaction in real time and were able to confirm the differentiation bone in all groups. Osteopontin had its greatest expression in G- PRP to seven days followed by G-PRP + DBM, at other times the G-PRP + DBM had higher expression than the other groups. The osteocalcin and Runx2 were expressed more intensely in the G-PRP + DBM at the end of the experiment. It can be concluded that the PRP and DBM are capable of promoting osteogenesis mesenchymal cells in Wharton's jelly of the umbilical cord with canine, with advantage in the presence of DBM
117

Transformador de estado sólido no controle de fluxo de potência em redes de distribuição /

Godoi, Lucas Antonio Alves de January 2018 (has links)
Orientador: Júlio Borges de Souza / Resumo: O transformador de estado sólido tem se apresentado como uma ferramenta indispensável na construção das novas redes elétricas inteligentes, uma vez que essa nova estrutura de rede altera o layout tradicional, viabilizando a conexão de fontes de energia descentralizadas. Contudo, essa conexão de sistemas de geração distribuída na rede originou a bidirecionalidade do fluxo de potência, resultando em um novo panorama para as atividades de operação e manutenção das redes para as distribuidoras de energia. A análise dos possíveis impactos técnicos gerados na rede de distribuição deve ser realizada, com o intuito de garantir um nível de qualidade energética dentro dos padrões estabelecidos pela Agência Nacional de Energia Elétrica – ANEEL. Dentre os impactos, destacam-se a elevação do nível de tensão e a alteração do fator de potência, ambos, produzidos pelo excesso de potência injetada na rede por este novo cenário de geração de energia. Nesse contexto, esta dissertação tem como principal objetivo analisar o comportamento de uma rede de distribuição genérica com penetração de geração distribuída e avaliar o perfil de tensão diante de diferentes níveis de inserção dessa geração na rede. As características de ajuste de tensão instantânea e capacidade de interação com sistemas de armazenamento que o transformador de estado sólido possui foram empregadas no auxílio da regulação dos níveis de tensão que se apresentaram fora dos padrões determinados pela resolução 794/2018 da ANEEL, qua... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The solid state transformer has been presented as an essential tool in the construction of new intelligent electric grids, since this new network structure changes the traditional layout, making possible the connection of decentralized energy sources. However, this connection of distributed generation systems in the network created the bidirectionality of the power flow, resulting in a new panorama for the power distributors concerning the networks activities of operation and maintenance. The analysis of the possible technical impacts generated in the distribution network should be carried out with the purpose of guaranteeing a level of energy quality within the standards established by the National Electric Energy Agency (ANEEL). Among the impacts, we highlight the elevation of the voltage level and the change in the power factor, both produced by the excess power injected into the grid by this new energy generation scenario. In this context, the main objective of this dissertation is to analyze the behavior of a generic distribution network with distributed generation penetration and to evaluate the voltage profile before different levels of insertion of this generation in the network. The solid state transformer has instantaneous voltage adjustment characteristics and interaction capacity with storage systems, which were used to aid in the regulation of voltage levels that were out of the standards determined by ANEEL resolution 794/2018, when a high level of distributed g... (Complete abstract click electronic access below) / Mestre
118

Transformador de estado sólido no controle de fluxo de potência em redes de distribuição / Solid state transformer in control of power flow in distribution networks

Godoi, Lucas Antonio Alves de 17 April 2018 (has links)
Submitted by Lucas Antonio Alves De Godoi (luksg@hotmail.com) on 2018-07-11T15:22:59Z No. of bitstreams: 1 Dissertação_Lucas _Godoi.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-07-11T17:29:00Z (GMT) No. of bitstreams: 1 godoy_laa_me_ilha.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) / Made available in DSpace on 2018-07-11T17:29:00Z (GMT). No. of bitstreams: 1 godoy_laa_me_ilha.pdf: 3300304 bytes, checksum: 429eb486ffbb167f9c7394e2d2e4b6f6 (MD5) Previous issue date: 2018-04-17 / O transformador de estado sólido tem se apresentado como uma ferramenta indispensável na construção das novas redes elétricas inteligentes, uma vez que essa nova estrutura de rede altera o layout tradicional, viabilizando a conexão de fontes de energia descentralizadas. Contudo, essa conexão de sistemas de geração distribuída na rede originou a bidirecionalidade do fluxo de potência, resultando em um novo panorama para as atividades de operação e manutenção das redes para as distribuidoras de energia. A análise dos possíveis impactos técnicos gerados na rede de distribuição deve ser realizada, com o intuito de garantir um nível de qualidade energética dentro dos padrões estabelecidos pela Agência Nacional de Energia Elétrica – ANEEL. Dentre os impactos, destacam-se a elevação do nível de tensão e a alteração do fator de potência, ambos, produzidos pelo excesso de potência injetada na rede por este novo cenário de geração de energia. Nesse contexto, esta dissertação tem como principal objetivo analisar o comportamento de uma rede de distribuição genérica com penetração de geração distribuída e avaliar o perfil de tensão diante de diferentes níveis de inserção dessa geração na rede. As características de ajuste de tensão instantânea e capacidade de interação com sistemas de armazenamento que o transformador de estado sólido possui foram empregadas no auxílio da regulação dos níveis de tensão que se apresentaram fora dos padrões determinados pela resolução 794/2018 da ANEEL, quando um alto nível de geração distribuída foi inserido na rede. / The solid state transformer has been presented as an essential tool in the construction of new intelligent electric grids, since this new network structure changes the traditional layout, making possible the connection of decentralized energy sources. However, this connection of distributed generation systems in the network created the bidirectionality of the power flow, resulting in a new panorama for the power distributors concerning the networks activities of operation and maintenance. The analysis of the possible technical impacts generated in the distribution network should be carried out with the purpose of guaranteeing a level of energy quality within the standards established by the National Electric Energy Agency (ANEEL). Among the impacts, we highlight the elevation of the voltage level and the change in the power factor, both produced by the excess power injected into the grid by this new energy generation scenario. In this context, the main objective of this dissertation is to analyze the behavior of a generic distribution network with distributed generation penetration and to evaluate the voltage profile before different levels of insertion of this generation in the network. The solid state transformer has instantaneous voltage adjustment characteristics and interaction capacity with storage systems, which were used to aid in the regulation of voltage levels that were out of the standards determined by ANEEL resolution 794/2018, when a high level of distributed generation was inserted into the network.
119

Filtros digitais recursivos para redução do impacto da resposta transitória do TPC.

SILVA, Célio Anésio da. 13 December 2017 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2017-12-13T16:54:10Z No. of bitstreams: 1 CÉLIO ANÉSIO DA SILVA - TESE (PPGEE) 2014.pdf: 1651226 bytes, checksum: a70dc4864a551f419c02ff41303eaffc (MD5) / Made available in DSpace on 2017-12-13T16:54:11Z (GMT). No. of bitstreams: 1 CÉLIO ANÉSIO DA SILVA - TESE (PPGEE) 2014.pdf: 1651226 bytes, checksum: a70dc4864a551f419c02ff41303eaffc (MD5) Previous issue date: 2014-05-29 / Capes / Um novo método de obtenção de parâmetros de filtros digitais recursivos (FDR) é apresentado para reduzir o impacto da resposta transitória dos Transformadores de Potencial Capacitivos (TPC) sobre o desempenho dos sistemas de medição, proteção e controle. Assumindo uma topologia predefinida, os parâmetros dos filtros são obtidos a partir da resposta em frequência do TPC de interesse. Diferentemente das técnicas reportadas na literatura, o método se aplica com facilidade a TPC de diferentes classes de tensão e independe das características operacionais do sistema. Para tanto, faz-se necessário conhecer a resposta em frequência do TPC em questão, no espectro de frequência de interesse. A validação do método é realizada através de simulações digitais em tempo real via simulador RTDSTM (Real Time Digital Simulator). As análises são baseadas em dados de sistemas elétricos reais e no funcionamento dinâmico dos filtros através da estimação dos fasores das tensões e estudos de localização de falta. A partir dos resultados obtidos, verifica-se que a presença dos FDR reduz significativamente os erros de medição causados pelos TPC quando submetidos a condições transitórias. Portanto, os FDR surgem como uma forma simples e de baixo custo para melhorar o desempenho e a confiabilidade dos sistemas de medição, proteção e controle. / A new method for obtaining recursive digital filter (FDR) parameters is presented in order to reduce the impact of Coupling Capacitor Voltage Transformer (CCVT) transient response on the performance of the measurement, protection and control systems. Assuming a pre-defined topology, the filter parameters are obtained from the CCVT frequency response of interest. Unlike the techniques reported in the literature, the method applies easily to CCVT of different voltage classes and it does not depend on the operating characteristics of the system, therefore, it is necessary to know the frequency response of the CCVT on the frequency spectrum of interest. The method is validated is through digital simulation using the RTDSTM (Real Time Digital Simulator). The analyzes are based on data obtained from electrical systems in service and on the dynamic performance of the filters by estimating the phasors of voltages and fault location studies. It is shown that the presence of FDR significantly reduces measurement errors caused by CCVT when subjected to transient conditions, therefore, the FDR arises as a simple and low cost alternative to improve the performance and reliability of measurement systems, protection and control.
120

Localização de descargas parciais em transformadores de potência por meio de sensores piezelétricos de baixo custo e sistemas inteligentes / Location of partial discharge in power transformers through a low cost piezoelectric sensors and intelligent systems

Castro, Bruno Albuquerque de [UNESP] 25 May 2016 (has links)
Submitted by Bruno Albuquerque de Castro null (bruno.castro@feb.unesp.br) on 2016-06-01T17:52:34Z No. of bitstreams: 1 Bruno_Albuquerque_de_Castro_MestradoEE.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-02T19:10:47Z (GMT) No. of bitstreams: 1 castro_ba_me_bauru.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5) / Made available in DSpace on 2016-06-02T19:10:47Z (GMT). No. of bitstreams: 1 castro_ba_me_bauru.pdf: 3788528 bytes, checksum: 28b69717116921fa999eda08254ac160 (MD5) Previous issue date: 2016-05-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O monitoramento e a localização precoce de descargas parciais em aparelhos de alta tensão, como nos transformadores de potência, são de fundamental importância para a prevenção de problemas funcionais associados à degradação contínua dos materiais que compõe o isolamento elétrico destes tipos de aparelho. Alguns fatores críticos na operação dos transformadores, como o funcionamento em sobrecarga, superaquecimento, transitórios e sinais elétricos de grande conteúdo harmônico vinculados a sistemas chaveados, em longo prazo, fazem com que o sistema de isolação de um transformador apresente degradação de suas propriedades físicas e químicas intrínsecas aos diversos tipos de materiais utilizados para esta finalidade e, deste modo, surjam descargas parciais. Este trabalho teve como objetivo aplicar sensores piezelétricos de baixo custo para a identificação e localização de descargas parciais em transformadores de potência por meio de sistemas inteligentes do tipo Redes Neurais e sistema de inferência neuro fuzzy adaptativos. Ambos os sistemas foram treinados com algumas métricas de processamento de sinais e os resultados de erro médio de localização chegaram na casa dos milímetros. Variou-se o número de sensores acoplados e foi realizado um estudo sobre os resultados de localização obtidos. / Partial discharge damages in power transformers require high cost monitoring procedures based on corrective maintenance or even interruptions of the power system. The development of online non-invasive monitoring systems to detect partial discharges in power transformers has great relevance since it can reduce significant maintenance costs. Some critical factors in the operation of transformers such as overload, nonlinear loads, transient voltage surges by atmospheric origin and switching, can make the insulation system of transformers to lose their physical and chemical properties. Therefore, these operating conditions can cause early deterioration of the insulation, causing internal partial discharges that may develop into major defects and thus shorten the useful life of electrical equipment. This research aimed to apply a low cost piezoelectric sensors for partial discharge identification and location in power transformers through intelligent systems such as neural networks and adaptive fuzzy inference system. Both systems were trained with some signal processing metrics and the results for location error was in the region of millimeters. It was varied the number of coupled sensors and a study was conducted on the obtained location results.

Page generated in 0.0861 seconds