• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 129
  • 80
  • 45
  • 8
  • 8
  • 7
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 338
  • 229
  • 107
  • 76
  • 43
  • 35
  • 35
  • 35
  • 34
  • 34
  • 32
  • 30
  • 28
  • 27
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito dos agrotóxicos e seus metabólitos em células sanguíneas / Effect of pesticides and their metabolites in blood cells

Neves, Fortunée Rosa Meyohas 10 March 2017 (has links)
Introdução: A Hemoterapia sempre ocupou espaço entre o científico e o místico. Os gregos reconheciam o sangue como sustentáculo da vida e no século XVII, com a descoberta da circulação sanguínea, por Willian Harvey, a possibilidade de transfusão foi postulada por estudiosos da época. O primeiro relato de transfusão foi o de um procedimento feito empregando a infusão de sangue de carneiro para paciente com tifo, que faleceu. No início do século XX, iniciou-se realmente uma fase de maior compreensão de riscos, e possíveis benefícios com a utilização de sangue, hemocomponentes e hemoderivados. Com o desenvolvimento tecnológico dessa área da saúde, a preocupação com a segurança tornou-se cada vez maior. Dentro desse contexto, o presente trabalho compila e discute a ação dos agrotóxicos, descrita na literatura, sobre o sangue e hemocomponentes a fim de averiguar o quanto se sabe sobre a segurança e eficácia da liberação da doação, a produção e a utilização de hemocomponentes e hemoderivados provenientes de doadores expostos a agrotóxicos. Metodologia: O presente trabalho compilou resultados e observações de cinquenta publicações cientificas sobre o efeito dos agrotóxicos no sangue, empregando a pergunta norteadora: \"O que sabemos para considerarmos segura a utilização de hemocomponentes e hemoderivados provenientes de doadores expostos a agrotóxicos?\". Conclusão: O trabalho relatou os principais agrotóxicos empregados no Brasil e no mundo, seus efeitos sobre seres humanos e hemocomponentes, principalmente hemácias e plaquetas. Os dados, dos trabalhos consultados durante essa pesquisa, indicam sobrevida diminuída de plaquetas e hemácias do sangue e que há metabólitos de agrotóxicos no plasma de indivíduos, potenciais doadores de sangue, expostos aos agrotóxicos. Surge portanto, a reflexão sobre a qualidade do hemocomponente obtido de doadores expostos aos agrotóxicos, e a necessidade de novos estudos / Introduction: Hemotherapy has always occupied a space between the scientific and mythical field. The Greeks acknowledged blood as the sinews of life and in the 17th century, with the discovery of the blood stream by Willian Harvey, the possibility of transfusion was postulated by experts at that time. The first report of transfusion was a procedure performed by employing the infusion of sheep blood into a patient with typhus who died. In the beginning of the 20th century, we began to truly understand the risks and possible benefits with the use of blood, blood components and derivatives. With the technological development in this health field, the concern with safety became even greater. In this context, this work compiles and discusses the action of pesticides, described in the literature, about blood and its components in order to ascertain how much it is known about the safety and effectiveness of the release to the donation, production, and use of blood components and derivatives from donors exposed to pesticides. Methodology: The present work assembled results and transcriptions from 50 scientific publications regarding the pesticides effect on peripheral blood components, guided by the hypothesis of how much we know to consider safe the use of blood components and derivatives from donors exposed to pesticides. Conclusion: The study listed the main pesticides used in Brazil and in the world, their effects in human beings and blood components, particularly in red blood cells and platelets. Data from the reference indicate the shortened survival of platelets and red blood cells and the presence of pesticides\' metabolites in the plasma of healthy individuals who are potential blood donors exposed to pesticides. It arises here the reflection on the quality of the blood components obtained to donors exposed to pesticides and need for novel studies
132

Effects of red blood cell transfusion on left ventricular output and oxygen consumption in premature infants.

January 1998 (has links)
by Yu Chung Wah. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1998. / Includes bibliographical references (leaves 85-102). / Abstract also in Chinese. / Chapter Section 1 --- Literature review / Chapter 1.1 --- Physiology of anemia in the prematurity --- p.1 / Chapter 1.11 --- Erythropoiesis and Erythropoietin --- p.2 / Chapter 1.12 --- Postnatal changes in oxygen transport and delivery --- p.3-6 / Chapter 1.2 --- The concept of oxygen supply and demand --- p.6-7 / Chapter 1.3 --- Compensatory response and adverse effects of anemia --- p.8 -9 / Chapter 1.4 --- Treatments of anemia --- p.9 / Chapter 1.41 --- Red blood cell transfusion --- p.9-13 / Chapter 1.42 --- Recombinant human erythropoietin (rHuEpo) --- p.13 -14 / Chapter 1.5 --- Methods of cardiac output measurements --- p.15 / Chapter 1.51 --- Determination of cardiac output by invasive method --- p.15 -19 / Chapter 1.52 --- Determination of cardiac output by non-invasive methods --- p.20 -30 / Chapter 1.6 --- Methods of oxygen consumption measurements --- p.31 -37 / Chapter 1.7 --- Haemodynamic effects of red blood cell transfusion in preterm infants . --- p.38 -39 / Chapter Section 2 --- Introduction --- p.40 -42 / Chapter Section 3 --- Methodology --- p.43-47 / Chapter Section 4 --- Results --- p.48-51 / Chapter Section 5 --- Discussion --- p.52 -56 / Chapter Section 6 --- Conclusion --- p.57 / Chapter Section 7 --- Future Direction --- p.58 / Chapter Section 7 --- Tables and Figures --- p.59-84 / Chapter Section 8 --- References --- p.85 -102
133

När ett Jehovas vittne avsäger sig blodtransfusion : Etiska problem som kan uppstå hos vårdaren vid en livsavgörande situation

M’boge Fredriksson, Lucille A., Torbjörnsson, Angelika January 2011 (has links)
Samfundet Jehovas vittnen avsäger sig blodtransfusion på grund av sin religiösa tro. Sjukvården ställs inför etiska problem när det uppstår en situation då patienten behöver blodprodukter. För vårdaren uppstår etiska konflikter mellan viljan att rädda liv, medicinska och juridiska aspekter samt patientens autonomi. Syftet med vår uppsats är att belysa de etiska problem som vårdaren kan möta i sjukvårdspraxis. Metoden som använts är en kvalitativ litteraturstudie och bygger på fyra vetenskapliga artiklar och en avhandling. I resultatet framgick det att det är en konfliktfylld situation då patienten nekar blodtransfusion och vårdaren har en roll att rädda liv men då går emot patientens självbestämmanderätt. De olika företrädarna för professionerna har olika syn på hälsa. Sjuksköterskan försätts i en konflikt mellan att respektera patientens autonomi eller att utföra läkarordinationen. För vårdpersonalen uppstår ytterligare ett problem när patienten är medvetslös och inte kan ge sin aktuella ståndpunkt gällande behandling. I resultatdiskussionen belyser vi att det inte finns några konkreta lösningar på de etiska problemen och att sjukvårdarna är dåligt förberedda på att hantera situationer som dessa. Vårdpersonal bör vara medveten om vilken inverkan kultur och religion har på människors liv och hur man ser på hälsa och sjukdom. Utbildning inom etik menar vi är en förutsättning för att kunna hantera de etiska problem som uppstår när patienten tillhörande Jehovas vittne avsäger sig blodtransfusion. Bristande kunskap i sjukvårdspraxis finns och därför behövs det vidare forskning och utbildning inom området för att kunna hantera dessa etiska problem. / Program: Sjuksköterskeutbildning
134

A transfusão sanguínea no perioperatório e a ocorrência da infecção de sítio cirúrgico / Perioperative blood transfusion and the occurrence of surgical site infection.

Mantoani, Camila Cristina 24 August 2012 (has links)
Trata-se de uma revisão integrativa da literatura com objetivo de identificar e analisar as evidências oriundas de estudos primários que abordaram a relação entre a transfusão sanguínea e a ocorrência da infecção de sítio cirúrgico, em pacientes adultos submetidos à cirurgia eletiva. A busca foi realizada em abril de 2012 nas bases de dados PUBMED/ MEDLINE, CINAHL, LILACS e Biblioteca Cochrane e utilizou-se o limite dos estudos indexados nos últimos 10 anos. Para a busca nas bases de dados eletrônicas foram utilizadas combinações entre os descritores controlados transfusão sanguínea, transfusão de componentes sanguíneos, cirurgia eletiva e infecção de ferida cirúrgica e os não-controlados infusão sanguínea, procedimento cirúrgico eletivo, cirurgia de não urgência e infecção de sítio cirúrgico, as quais resultaram na identificação de 2195 referências, dentre essas, 2112 foram excluídas devido a ausência em relação ao tema a partir da leitura de título e resumo. Assim, 73 estudos mostraram-se elegíveis e foram lidos na íntegra, dentre os quais, 50 estudos não foram selecionados e cita-se como motivo de exclusão para cinco estudos, que não analisavam a relação da infecção de sítio cirúrgico e a transfusão sanguínea, dois estudos incluíam indivíduos com idade inferior a 18 anos, 33 estudos consideravam cirurgias de urgência e emergência, quatro estudos transfundiam plasma e plaquetas e seis estudos não referenciavam infecção de sítio cirúrgico. Dentre os 33 estudos selecionados, 16 constavam de estudos repetidos e 17 estudos primários foram selecionados e incluídos na amostra, pois atenderam aos critérios de seleção da revisão. Para extração dos dados foi utilizado um instrumento validado. A análise dos dados foi descritiva e apresentada em duas categorias temáticas: pacientes que recebiam transfusão sanguínea e apresentavam a infecção de sítio cirúrgico como desfecho infeccioso; e pacientes com infecção de sítio cirúrgico, para os quais a transfusão sanguínea foi verificada como um fator de risco independente. As variáveis clínicas e cirúrgicas relacionadas com maior frequência e significância nos estudos foram: níveis de hemoglobina, perda sanguínea intra-operatória, quantidade de sangue transfundido, tempo de operação, escore do ASA, classificação da cirurgia e uso de antibiótico profilático. E a maior ocorrência de infecção de sítio cirúrgico foi verificada em mulheres, de maior idade e índice de massa corporal para obesidade. Um aspecto positivo a ser ressaltado é que a definição da infecção de sítio cirúrgico utilizada nos estudos primários incluído foi a mesma. No entanto, há necessidade de consenso para os níveis de hemoglobina indicativos de transfusão sanguínea e a implementação de assistência de enfermagem direcionada ao atendimento das reais necessidades deste paciente, minimizando os riscos e complicações inerentes ao procedimento anestésico-cirúrgico, educação para e vigilância pós-alta hospitalar para identificação precoce de infecção de sítio cirúrgico em pacientes submetidos à Obrigada pela força, cumplicidade e convivência. transfusão sanguínea. / The aim of this integrative literature review was to identify and analyze evidence from primary studies on the relation between blood transfusion and the occurrence of surgical site infection in adult patients submitted to elective surgery. The search was accomplished in April 2012 in the databases PUBMED/ MEDLINE, CINAHL, LILACS and the Cochrane Library and was limited to studies indexed in the last 10 years. For the electronic database search, combinations were used among the controlled descriptors blood transfusion, blood component transfusion, elective surgery and surgical site infection and the non-controlled descriptors blood infusion, elective surgical procedure, non-urgent surgery and surgical site infection, which resulted in the identification of 2195 references. Of these, 2112 were excluded due to the lack of relation with the theme, based on the reading of the title and abstract. Thus, 73 studies were eligible and were fully read, 50 of which were not selected. For five studies, the reason for exclusion was that they did not analyze the relation between the surgical site infection and the blood transfusion, two studies included individuals younger than 18 years of age, 33 studies considered urgency and emergency surgeries, four studies transfused plasma and platelets and six studies did not refer to surgical site infection. Among the 33 selected studies, 16 were repeated, so that 17 primary studies were selected and included in the sample, as they complied with the selection criteria for the review. To extract the data, a validated instrument was used. Data analysis was descriptive and presented in two thematic categories: patients who received a blood transfusion and presented surgical site infection as an infectious outcome; and patients with surgical site infection, for whom the blood transfusion was verified as an independent risk factor. The most frequently and significantly related clinical and surgical variables in the studies were: hemoglobin levels, intraoperative blood loss, amount of blood transfused, duration of surgery, ASA score, surgery classification and use of prophylactic antibiotics. And the highest incidence levels of surgical site infection were found in older women whose body mass index indicated obesity. One positive aspect to be highlighted is that the definition of surgical site infection used in the included primary studies was the same. A consensus is needed on what hemoglobin levels indicate blood transfusion and the implementation of nursing care in response to these patients\' actual needs, minimizing the risks and complications inherent in the anesthetic- surgical procedure, education for and surveillance after hospital discharge with a view to the early identification of surgical site infection in patients submitted to blood transfusion.
135

Avaliação da qualidade in vitro do concentrado de hemácias felino colhido e armazenado em sistema manufaturado / Evaluation of the in vitro quality of the feline packed red blood cells collected and stored in manufactured system

Fujimura, Lilian Sayuri Tatibana 26 February 2013 (has links)
Esse estudo teve por objetivo avaliar a viabilidade e qualidade in vitro do concentrado de hemácias felino (CHF), colhido e armazenado em bolsas e produtos nacionais, remanufaturadas, pelo Laboratório de Hemoterapia do Serviço de Anestesia da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo, de acordo com normas definidas por órgãos regulamentadores como a ANVISA. Foram analisados parâmetros bioquímicos e hematológicos de 24 unidades de CHF nos dias 0, 14 e 21 de armazenamento. Utilizou-se sistema fechado para colheita e armazenamento do sangue com solução de anticoagulante-preservativa CPDA-1. A avaliação consistiu na mensuração de porcentagem de hematócrito, hemoglobina total, hemoglobina extracelular, porcentagem de hemólise, concentrações de potássio, lactato, glicose, ATP, pH, bicarbonato, pressão de CO2 e O2, inspeção visual da bolsa e cultura microbiológica aeróbia e anaeróbia. Os resultados obtidos foram avaliados estatisticamente por meio de testes paramétricos, sendo que as determinações de hematócrito, hemoglobina total não apresentaram variação significante nos 21 dias de preservação, enquanto os de potássio, lactato, pO2 aumentaram gradativamente de forma significante. Os níveis de ATP, glicose, pH, bicarbonato e pCO2 reduziram de forma significante com o decorrer do tempo. Não houve alteração à inspeção visual das bolsas de sangue, nem crescimento de microorganismos nas culturas realizadas. Por meio destas avaliações constatouse que o sistema remanufaturado com produtos nacionais pode ser empregado com segurança para obtenção de sangue felino tendo-se em vista que se manteve estéril, com eficiente conservação do concentrado de hemácias felino em CPDA-1 até o 21º dia de armazenamento. / This study aimed to evaluate the feasibility and quality of in vitro feline packed red blood cells (CHF), harvested and stored in bags and domestic products, manufactured, Hematology Laboratory at the Department of Anesthesia, Faculty of Veterinary Medicine, University of São Paulo, according to standards set by regulatory bodies such as ANVISA. Were analyzed biochemical and hematological parameters 24 units of CHF on days 0, 14 and 21 of storage. We used a closed system for collection and storage of blood with preservative-anticoagulant solution CPDA-1. The evaluation consisted in measuring percentage of hematocrit, total hemoglobin, extracellular hemoglobin, percentage of hemolysis, potassium concentrations, lactate, glucose, ATP, pH, bicarbonate, CO2 and O2 pressure, visual inspection of the bag and aerobic and anaerobic microbiological culture . The results were statistically analyzed using parametric tests, and determinations of hematocrit, total hemoglobin showed no significant variation within 21 days of preservation, while potassium lactate, pO2 gradually increased significantly. ATP levels, glucose, pH, pCO2 and bicarbonate decreased significantly with time. There was no change to the visual inspection of blood bags, or growth of microorganisms in the cultures performed. Through these evaluations it was found that the system refilled with domestic products can be used safely for obtaining blood feline bearing in mind that remained sterile, efficient storage of red blood cells feline in CPDA-1 until the 21 th days of storage.
136

Validação de teste ELISA para pesquisa de anticorpos anti-MSP119 de Plasmodium vivax visando à aplicação em serviços hemoterápicos do Brasil em áreas não endêmicas para malária / Validation of ELISA for Plasmodium vivax MSP119 antibodies aiming at the application in Brazilian haemotherapic services in malaria non-endemic areas

Sanchez, Arianni Rondelli 11 December 2014 (has links)
A malária transmitida por transfusão (MTT), embora seja um evento raramente relatado em áreas não endêmicas ou de baixa endemicidade, representa um desafio devido à ocorrência de infecções assintomáticas e à possibilidade de sobrevivência de Plasmodium em hemácias estocadas por até três semanas a temperaturas entre 2 e 6ºC. No Estado de São Paulo, quatro casos de MTT foram relatados, incluindo uma morte. Os doadores infectados foram identificados como portadores assintomáticos que viviam ou haviam se deslocado para o bioma Mata Atlântica do estado. Nesses doadores, geralmente as densidades parasitárias são baixas e indetectáveis pela gota espessa ou testes rápidos. O uso de plataformas incluindo testes sorológicos poderia detectar doadores suspeitos de infecção por Plasmodium, minimizando a possibilidade de MTT. Nesse sentido, o objetivo deste estudo foi padronizar a produção de antígeno recombinante MSP119 de P. vivax, que é a espécie mais prevalente no Brasil, e validar o teste ELISA-PvMSP119, visando à aplicação em serviços hemoterápicos brasileiros de áreas não endêmicas para malária. O antígeno recombinante produzido em condições desnaturantes mostrou-se adequado para a produção em larga escala, pela facilidade de obtenção e purificação. Os resultados de estabilidade obtidos em três lotes-piloto indicaram validade de pelo menos 27 meses sem perda de reatividade. Além disso, o teste apresentou 96,95% de sensibilidade em 197 soros de pacientes com gota espessa positiva para P. vivax e especificidade de 100,00% utilizando soros de 101 indivíduos controles sadios e 99,26% quando considerados também 168 amostras de soro de pacientes com outras doenças. O coeficiente de variação das amostras positivas foi <= 3,8% para a repetitividade e <= 10,6% para a reprodutibilidade. Quanto à reatividade cruzada, obtiveram-se falsos resultados positivos com amostras de doença de Chagas (5,88%) e fator reumatoide (6,67%). Após a validação, avaliou-se a prevalência de anticorpos IgG anti-MSP119 de P. vivax entre doadores de sangue do Sudeste do Brasil, considerados aptos à doação, ensaiando 1.974 amostras de plasma de bancos de sangue, sendo 1.309 do Estado São Paulo (SP) e 665 do Estado do Rio de Janeiro (RJ). A positividade entre as amostras de SP foi 1,15% (N = 15) e entre as do RJ foi 1,65% (N = 11). O índice de reatividade (IR) das amostras positivas variou entre 8,98-1,16 (SP) e 13,03-1,08 (RJ). Em SP e RJ, maior positividade foi encontrada nos municípios que têm contato com o bioma Mata Atlântica e no RJ, também no bairro da Tijuca, onde se encontra a Floresta da Tijuca. A presença de anticorpos IgG anti-P. vivax não é necessariamente um marcador de parasitemia ou doença, porém aponta para o risco de MTT, mesmo em áreas de baixa endemicidade, pois doadores assintomáticos podem ser aceitos com base em triagem clínica. Estes achados constituem-se em alerta que nos impele a rever os critérios adotados para a seleção dos doadores, com o objetivo de reduzir o risco de MTT nessas áreas sem perder doações. / In non-endemic and low endemic areas, transfusion-transmitted malaria (TTM) is a rarely reported event, representing a major challenge, essentially due to the occurrence of asymptomatic infections and to the possibility of Plasmodium survival up to three weeks in stored red blood cells at temperatures between 2 and 6ºC. In São Paulo State, four TTM were detected, including one death. Infected donors were identified as asymptomatic carriers that lived or that had displacements to the Atlantic forest biome in the state. In these donors generally the parasite densities are low and undetectable in the thick blood smear or rapid diagnostic tests. The use of platforms including serological tests might point out donors suspected of harboring Plasmodium, minimizing the possibility of TTM. Accordingly, the aim of this study was to standardize the production of P. vivax MSP119 recombinant antigen, which is the most prevalent species in Brazil, and validate ELISA-PvMSP119, aiming at the application in Brazilian haemotherapic services in malaria non-endemic areas. The recombinant antigen produced under denaturing conditions was suitable for large-scale production, due to the ease of obtaining and purification. The results of stability obtained in three pilot batches indicated that it was valid for at least 27 months without loss of reactivity. Furthermore, the test showed 96.95% sensitivity in sera from 197 patients with positive thick-blood smear for P. vivax and 100.00% specificity in sera from 101 healthy controls, and 99.26% when considered also 168 samples from patients with other diseases. The variation coefficient of positive samples was <= 3.8% for repeatability and <=10.6% for reproducibility. For cross-reactivity, false positive results were obtained with Chagas\' disease (5.88%) and rheumatoid factor (6.67%) samples. After validation, we evaluated the prevalence of IgG anti-MSP119 antibodies to P. vivax among blood donors in Southeastern Brazil, considered suitable for donation, rehearsing 1,974 plasma samples from blood banks, being 1,309 from the State of São Paulo (SP) and 665 from the State of Rio de Janeiro (RJ). The positivity among samples from SP was 1.15% (N = 15) and in RJ was 1.65% (N = 11). The reactivity index (RI) of the positive samples ranged from 8.98 to 1.16 (SP) and from 13.03 to 1.08 (RJ). In SP and RJ, highest positivity was seen in Municipalities in contact to the Atlantic Forest biome, and in RJ, also in the Tijuca neighborhood, where there is the Tijuca Forest. The detection of IgG antibodies is not necessarily a marker of parasitemia or disease, however, points out to the risk of TTM, even in areas of low endemicity, since asymptomatic donors could be accepted based on clinical screening. These findings constitute an alert that impel us to review the adopted criteria for screening of the donors aiming to reduce the risk of TTM in these areas without losing donations.
137

Factibilidade e reprodutibilidade da avaliação da restrição de difusão de água por meio da ressonância magnética no cérebro do feto na síndrome de transfusão feto-fetal : Feasibility and reproducibility of diffusion-weighted magnetic resonance imaging of the fetal brain in twin-twin transfusion syndrome / Feasibility and reproducibility of diffusion-weighted magnetic resonance imaging of the fetal brain in twin-twin transfusion syndrome

Santos Neto, Orlando Gomes dos, 1976- 27 November 2018 (has links)
Orientador: Cleisson Fábio Andrioli Peralta / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-11-27T11:52:28Z (GMT). No. of bitstreams: 1 SantosNeto_OrlandoGomesdos_M.pdf: 1132176 bytes, checksum: d5202b7fe95c1aed116aef2fa03d7e3b (MD5) Previous issue date: 2013 / Resumo: Introdução: As lesões neurológicas fetais são importante causa de morbimortalidade neonatal. Uma condição relativamente frequente que expõe os fetos a maior risco de lesão cerebral é a síndrome da transfusão feto-fetal grave (STFF). O tratamento de escolha para STFF consiste na ablação dos vasos placentários com laser (AVPL) e mesmo após a sua realização existe possibilidade de lesão neurológica fetal. A ultrassonografia (USG) é ainda o método de escolha para a avaliação de anormalidades encefálicas fetais, e a ressonância magnética (RNM) pode melhorar o diagnóstico em condições específicas. Entretanto, a USG e as imagens ponderadas T1 e T2 da RM não são apropriadas para a detecção de lesões isquêmicas. A Restrição de Difusão da ressonância magnética (RD-RNM) permite a detecção de eventos isquêmicos agudos no cérebro através da avaliação subjetiva e objetiva da difusão microscópica da água. Esta última pode ser obtida por meio da medida do coeficiente de difusão aparente (CDA) e sua reprodutibilidade no cérebro fetal normal, em gestações únicas, foi recentemente demonstrada. Objetivo: Testar a factibilidade e a reprodutibilidade da restrição de difusão da ressonância magnética nas avaliações do cérebro fetal em casos de síndrome de transfusão feto-fetal tratados com a ablação dos vasos placentários com laser. Materiais e Métodos: Este estudo foi realizado no período de maio de 2011 a junho de 2012, após aprovação pelo Comitê de Ética em Pesquisa da FCM/UNICAMP. Pacientes com STFF grave realizaram uma ressonância magnética para a avaliação do cérebro dos fetos antes e depois da AVPL. Os dados foram analisados off-line em imagens axiais da restrição de difusão (RD) e em mapas do coeficiente de difusão aparente por dois radiologistas. A avaliação subjetiva foi descrita como a ausência ou a presença de restrição de difusão da água. A avaliação objetiva foi realizada através da colocação de regiões de interesse circulares de 20 mm2 nas imagens de RD e em mapas de CDA. A concordância subjetiva inter observadores foi avaliada pelo coeficiente de correlação de Kappa. As medidas do CDA realizadas pelo mesmo observador e por observadores diferentes foram comparadas por meio de testes de Bland-Altman proporcionais. Resultados: As análises foram realizadas em 23 pacientes (46 fetos) com STFF grave, antes e após a AVPL, totalizando noventa e dois exames RD-RNM. Destes, 62 (67%) foram considerados de boa qualidade para avaliação. A concordância entre os radiologistas foi de 100% tanto para a ausência (55/62 = 89%) quanto para a presença (7/62=11%) de restrição de difusão da água. Com relação às concordâncias intra e inter-observadores das medidas do CDA, o teste de Bland-Altman mostrou diferenças percentuais médias de menos de 1,5% e Intervalo de Confiança (IC) de 95% em menos de 18% em todos os locais avaliados. Conclusões: Nossos dados sugerem que a avaliação RD-RNM do cérebro fetal em STFF é factível e reprodutível. Este método pode representar uma ferramenta útil para o aconselhamento dos pais sobre a evolução neurológica de seus filhos / Abstract: Introduction: The fetal neurological injuries are an important cause of neonatal morbidity and mortality. Severe twin-twin transfusion syndrome (TTTS) is a relatively frequent condition that exposes the fetuses to a higher risk of brain injury. The treatment of choice for TTTS consists in laser ablation of placental vessels (LAPV) and even after its completion there is the possibility of fetal neurologic injury. Ultrasonography (USG) is still the method of choice for evaluation of fetal brain abnormalities, and magnetic resonance imaging (MRI) can improve the diagnostic in specific conditions. However, ultrasonography and the T1 and T2 weighted images of MRI are not suitable for detection of ischemic lesions. Diffusion-weighted (DW) MRI enables the detection of acute hypoxic-ischemic events in the brain through subjective and objective evaluation of the microscopic diffusion of water. An objective evaluation consists of measuring the apparent diffusion coefficient (ADC): the reproducibility of this method in the normal fetal brain in singleton pregnancies was recently demonstrated. Purpose: To test the feasibility and reproducibility of diffusion-weighted magnetic resonance imaging (DW-MRI) evaluations of fetal brains in cases of twin-twin transfusion syndrome treated with laser ablation of placental vessels. Materials and Methods: This study was conducted from May 2011 to June 2012, after approval by the Institutional Review Board of FCM/UNICAMP. Patients with severe TTTS received an MRI scan for the evaluation of fetal brain before and after LAPV. Datasets were analyzed offline on axial DW images and apparent diffusion coefficient (ADC) maps by two radiologists. The subjective evaluation was described as the absence or presence of water diffusion restriction. The objective evaluation was performed by the placement of 20-mm2 circular regions of interest on the DW image and ADC maps. Subjective inter-observer agreement was assessed by the Kappa correlation coefficient. ADC measurements performed by the same observer and by different observers were compared using proportionate Bland-Altman tests. Results: Analyses were performed in 23 patients (46 fetuses) with severe TTTS before and after LAVP totaling 92 examinations RD-RM. Of these, 62 (67%) were of good quality for evaluation. The agreement between radiologists was 100% in the absent (55/62 = 89%) and in the presence (7/62 = 11%) of restricted diffusion of water. With respect to intra and inter-observer measurements of the ADC, the Bland-Altman plots showed average percentage differences of less than 1.5% and Confidence Interval (CI) of 95% in less than 18% in all regions evaluated. Conclusions: Our data suggest that DW-MRI evaluation of the fetal brain in TTTS is feasible and reproducible. This method may represent a useful tool for counseling parents about the neurological outcome of their infants / Mestrado / Saúde Materna e Perinatal / Mestre em Tocoginecologia
138

Avaliação externa da qualidade em imuno-hematologia de serviços transfusionais da área de abrangência da grande São Paulo / External evaluation of quality in immunohematology of the transfusion services of the comprehensive area of greater São Paulo

Neto, Thays [UNESP] 09 December 2016 (has links)
Submitted by THAYS NETO null (thays_neto@hotmail.com) on 2017-02-14T12:19:41Z No. of bitstreams: 1 Dissertação final corrigida Thays1.pdf: 2190291 bytes, checksum: 9e23877fdf7cbe05ad85fc4d79544592 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-02-15T13:41:39Z (GMT) No. of bitstreams: 1 neto_t_me_bot.pdf: 2190291 bytes, checksum: 9e23877fdf7cbe05ad85fc4d79544592 (MD5) / Made available in DSpace on 2017-02-15T13:41:39Z (GMT). No. of bitstreams: 1 neto_t_me_bot.pdf: 2190291 bytes, checksum: 9e23877fdf7cbe05ad85fc4d79544592 (MD5) Previous issue date: 2016-12-09 / A Coordenação Geral de Sangue e Hemoderivados CGSH, do Ministério da Saúde, comprometida com a missão de elaborar políticas que promovam o acesso da população à atenção hematológica e hemoterápica de forma segura e com qualidade, desenvolve suas ações em consonância com os princípios e as diretrizes do Sistema Único de Saúde – SUS e através da ANVISA implantou em 2001 a Avaliação Externa da Qualidade em Imuno-hematologia (AEQIH) contando com 8 unidades produtoras (UP). Em 2005 o Hemocentro de Botucatu passou a integrar as UP. Este trabalho tem como objetivo avaliar o desempenho dos serviços de hemoterapia (SH) da área de abrangência da Grande São Paulo, sob responsabilidade da UP de Botucatu no período de 2005-2015 levando em consideração diferentes indicadores: número de serviços atendidos/índice de adesão; erros e acertos nas técnicas de tipagem ABO e RhD, pesquisa de anticorpos irregulares (PAI), identificação de anticorpos irregulares (IAI), teste da antiglobulina direta (TAD), prova cruzada (PC) e fenotipagem eritrocitária (FE). A análise estatística realizada foi a de regressão linear, teste de correlação de Spearman e Curva ROC. Durante os 10 anos foram enviados 29 painéis práticos contendo 4 tipagens ABO e RhD (n=10.382), 2 amostras para PAI, IAI e TAD (n=5.191 respectivamente), PC (n=1.611) e FE (n=1.074) e 21 avaliações teóricas (18.975 questões). A média de SH participantes durante o período determinado foi de 89,5. O índice de crescimento, levando em consideração o número de serviços avaliados em 2005 e aqueles em 2015, indica um crescimento de 26,6%. Quanto à avaliação dos painéis práticos, o desempenho dos indicadores avaliados foi: ABO> RhD> PC>TAD>PAI>IAI>FE. Na avaliação individual o desempenho dos indicadores avaliados foi: IAI>PAI>FE>PC>ABO>TAD>RhD. Foram identificados 28 SH com o pior desempenho em mais de um parâmetro avaliado (24,13% do total): dos sete parâmetros avaliados, erraram dois deles (71%), três (11%), quatro (14%) e cinco (4%). O teste de correlação de Spearman identificou que o pior desempenho prático tem relação com o perfil dos serviços que não executam determinadas técnicas, bem como aqueles que têm dificuldade de responder a questionários. O percentual geral de acertos da avaliação teórica não apresenta tendência de resultados estáveis. O percentual individual de acertos da avaliação teórica varia de 80% a 99,9%. / The General Coordination of Blood and Hemoderivatives, of the Ministry of Health, committed to the mission of developing policies that promote the population's access to hematological and hemotherapeutic care in a safe and quality way, develops its actions in accordance with the principles and guidelines Of the Unified Health System and through ANVISA implemented in 2001 the External Evaluation of Quality in Immunohematology with 8 production units (PU). In 2005 the Botucatu Blood Transfusion Center became part of the UP. This study aims to evaluate the performance of hemotherapy services (HS) in the Greater São Paulo area, under the responsibility of the PU of Botucatu in the period 2005-2015, taking into account different indicators: number of services attended / rate of adherence; Errors in ABO and RhD typing techniques, irregular antibody test (IAT), identification of irregular antibodies (IAI), direct antiglobulin test (DAT), cross-test (CT) and erythrocyte phenotyping (EP). Statistical analysis was performed using linear regression, Spearman correlation test and ROC curve. During the 10 years, 29 practical panels containing 4 ABO and RhD typing (n = 10,382), 2 samples for IAT, IAI and DAT (n = 5,191 respectively), CT (n = 1,611) and EP (n = 1,074) were sent and 21 theoretical evaluations (18,975 questions). The mean number of participants during the study period was 89.5. The growth rate, taking into account the number of services evaluated in 2005 and those in 2015, indicates a growth of 26.6%. Regarding the evaluation of the practical panels, the performance of the indicators evaluated was: ABO>RhD>CT>DAT>IAT>IAI>EP. In the individual evaluation, the performance of the indicators evaluated was: IAI>IAT>EP>CT>ABO>DAT>RhD. RESULTS: Twenty-eight HS patients (71%), three (11%), four (14%) and five (11%) were found to be the worst performers in more than one parameter evaluated (24.13% of the total). The Spearman correlation test identified that the worst practical performance is related to the profile of services that do not perform certain techniques, as well as those that have difficulty answering questionnaires. The general percentage of correctness of the theoretical evaluation does not present a trend of stable results. The individual percentage of correctness of the theoretical evaluation varies from 80% to 99.9%.
139

Avaliação das células T reguladoras após transfusão de hemocomponentes

Capra, Marcelo Eduardo Zanella January 2013 (has links)
Introdução: Desde a década de 1970, quando se observou que a transfusão pré-transplante renal diminuía a rejeição ao enxerto, o efeito transfusion-related immunomodulation (TRIM) vem sendo estudado, não havendo, ainda, um entendimento completo de seu mecanismo. Recentemente, a descrição das células T reguladoras (TREG) trouxe novas possibilidades de compreensão desse fenômeno, com grande implicação terapêutica. Objetivos: Avaliar a proporção de células TREG antes e após a transfusão de concentrado de hemácias em uma amostra de pacientes clínicos não imunossuprimidos e correlacionar os resultados com o volume transfundido e o tempo de estocagem do sangue. Métodos: Pacientes com diversas patologias clínicas e com indicação de transfusão de concentrado de hemácias foram recrutados consecutivamente. Após assinatura do consentimento informado, o número de células TREG pré e pós-transfusão foi avaliado, bem como sua correlação com o número de unidades transfundidas e o tempo de estocagem. Resultados: Observou-se um aumento estatisticamente significativo na proporção de células TREG (CD4+, CD25+, FOXP3+) 72 horas após a transfusão (p=0,003). Tal aumento mostrou correlação com o número de unidades transfundidas, mas não com o tempo de estocagem (p=0,017 e 0,49, respectivamente). Conclusão: O aumento do numero de células TREG parece estar presente após transfusão de hemácias não leucodepletadas mesmo em uma amostra heterogênea, o que reforça sua importância clínica. A influência do número de unidades mas não do tempo de estocagem corrobora estudos anteriores. O mecanismo molecular do efeito TRIM, bem como seu impacto clínico em um cenário real, ainda precisam ser melhor avaliados. / Background: Transfusion-related immunomodulation (TRIM) has been the subject of research since the 1970s, when transfusion before kidney transplantation was found to decrease the rates of allograft rejection, but the mechanisms underlying this effect have yet to be fully elucidated. The recent description of regulatory T cells (TREG) has paved the way for a new understanding of this phenomenon, with major therapeutic implications. Objectives: To assess the levels of TREG cells before and after transfusion of packed red blood cells in a clinical sample of non-immunosuppressed patients and to correlate findings with the volume of blood transfused and length of storage. Methods: Patients with a variety of clinical conditions and with an indication for transfusion of packed red blood cells were recruited consecutively. After providing informed consent, pre- and post-transfusion TREG levels were measured, and their correlation with number of units transfused and length of storage was assessed. Results: There was a significant increase in the levels of TREG cells (CD4+/CD25+/FOXP3+) within 72 hours of transfusion (p=0.003). This increase correlated with the number of units transfused, but not with length of storage (p=0.017 and 0.49, respectively). Conclusion: An increase in TREG cell levels appears to follow transfusion of non-leukoreduced packed red blood cells even in a heterogeneous sample, which highlights the clinical relevance of this phenomenon. The influence of number of transfused units, but not of length of storage, on the results corroborates the findings of previous non-clinical studies. Further research is warranted to better investigate the molecular mechanism of the TRIM effect, as well as its clinical impact in real-world settings.
140

Avaliação bioquímica in vitro do concentrado de eritrócitos felino Armazenado em soluções de cpda-1 e cpd/sagm durante 35 dias / Biochemistry changes of feline erythrocyte concentrates stored in cpda-1 and cpd-sagm during 35 days

Sonaglio, Franciele January 2014 (has links)
O curto tempo de armazenamento dos hemocomponentes é um dos fatores que dificulta e limita a quantidade de sangue que pode ser efetivamente armazenada, o que é uma desvantagem na medicina veterinária, pois o acesso a doadores é restrito e a demanda é contínua e cada vez maior na prática de clínicas e hospitais veterinários. Durante o armazenamento do sangue em baixas temperaturas, seja sob a forma de sangue total ou concentrado de eritrócitos, há uma queda intensa de metabólitos importantes para a viabilidade e funcionalidade dos eritrócitos. O desenvolvimento de meios e soluções de preservação sanguínea possibilitou o armazenamento dos eritrócitos e, consequentemente, facilitou o trabalho dos bancos de sangue. Portanto, a busca por melhores formas e soluções para preservação capazes de evitar ou diminuir estes efeitos prejudiciais durante o seu armazenamento é contínua, para que ao final se obtenha uma melhor qualidade do sangue transfundido. O presente trabalho avaliou o concentrado de eritrócitos felino armazenado na solução de CPDA-1 e CPD/SAGM durante 35 dias. Os dados laboratoriais foram comparados entre grupos e ao longo do tempo. Neste experimento foram utilizadas 10 bolsas de concentrado de eritrócitos felino divididos em dois grupos de cinco para avaliação de cada um dos aditivos. Os parâmetros laboratoriais K+, Na+, Cl-, lactato, HCO3-, amônia, glicose e pH foram avaliados nos dias 1, 7, 14, 21, 28 e 35 após a coleta. Vários parâmetros (K+, lactato, HCO3, glicose e cloreto) demonstraram que a solução CPD/SAGM manteve o metabolismo energético do eritrócito mais estável. Com este trabalho, foi possível entender melhor as alterações metabólicas sofridas pelos eritrócitos felinos durante o armazenamento. Concluímos que, apesar da solução CPD/SAGM se mostrar mais eficaz in vitro, são necessários mais estudos com relação aos hemocomponentes em gatos e à sua viabilidade pós-transfusional. / The short shelf life of blood products is one factor that complicates and limits the amount of blood that can be effectively stored, and it is a disadvantage in veterinary practice, because the access to donors is restricted and the demand is continuous and increasing at veterinary clinics and hospitals. During blood storage at low temperatures, either as whole blood or as packed red cells, there is a significant decrease of metabolites that are important for the viability and functionality of erythrocytes. The development of blood preservation solutions has enabled the storage of red blood cells and improved the service at the blood banks. Therefore, the search for better ways and blood preservation solutions to avoid or reduce these harmful effects during the storage conditions is continuous, in order to obtain the best blood product to be transfused. This study evaluated 10 bags of feline erythrocyte concentrate divided into two groups, stored in CPDA-1 and CPD/SAGM solutions during 35 days. The laboratory data were compared between groups and over time. K+, Na+, Cl-, lactate, HCO3-, ammonia, glucose and pH were assessed on days 1, 7, 14, 21, 28, and 35 after collection. On various parameters (K+, Cl-, HCO3-, glucose and lactate) solution of CPD/SAGM kept the energy metabolism of red blood cells more stable. With these results we can better understand the biochemical changes of feline erythrocytes during storage. We conclude that, although the CPD/SAGM solution shown to be more effective, more studies are needed to improve knowledge of feline blood components and post-transfusion viability.

Page generated in 0.1033 seconds