• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 65
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 200
  • 200
  • 67
  • 53
  • 31
  • 29
  • 24
  • 23
  • 21
  • 15
  • 14
  • 14
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo comparativo da densidade e topografia de neurônios de retinas de Philodryas olfesii e P. patagoniensis (serpentes, colubridae)

Einat Hauzman 16 April 2009 (has links)
As serpentes são um grupo altamente diversificado, encontradas em praticamente todas as regiões do planeta, ocupando diferentes ambientes. Sua diversidade adaptativa indica a grande variabilidade dos órgãos sensoriais, adaptados ao hábitat e hábitos de cada espécie. Estudos sobre o sistema visual das serpentes são escassos e tem grande importância na compreensão de caracteres ecológicos, comportamentais e filogenéticos. Nos vertebrados as informações visuais são projetadas na retina e inicialmente processadas nessa camada neural, antes do processamento que ocorre no sistema nervoso central. Os tipos de células encontradas na retina, bem como sua densidade e distribuição variam entre as espécies e determinam especializações do sistema visual. Neste trabalho foi feita uma quantificaçao comparativa de fotorreceptores e neurônios da camada de células ganglionares (CCG) de duas espécies de serpentes colubrídeas diurnas, Philodryas olfersii e P. patagoniensis. Para tanto foram utilizadas técnicas de imunohistoquímica de opsinas e de marcação de Nissl. Serpentes adultas obtidas no Instituto Butantan foram anestesiadas com tiopental (30mg/kg) e sacrificadas com CO2. Os olhos foram enucleados e as retinas dissecadas e fixadas em paraformaldeido 4%. Um olho de cada serpente foi utilizado para fazer cortes radiais e testar diferentes tipos e concentrações de anticorpos. Para a preparação das retinas planas foram utilizados o anticorpo JH455, produzido em coelhos contra opsinas sensíveis aos comprimentos de onda curto de humanos (cones S) e o anticorpo JH492, produzido em coelhos contra opsinas sensíveis aos comprimentos de onda médio e longo de humanos (cones L/M). Foi utilizado anticorpo secundário biotinilado (gt -rb biot) e a revelação feita com estreptavidina acoplada a molécula florescente CY3. Os cortes radiais e as retinas planas foram observadas em microscópio fluorescente equipado com câmara digital conectada a microcomputador dotado de programa para captura de imagens. A partir de imagens da retina obtidas com espaçamento mínimo de 0,5 mm foram feitas as contagens das células e os mapas de isodensidade celular. A densidade média dos fotorreceptores foi semelhante nas duas espécies (11.183,1 ± 1.107,4 células/mm2 em P. olfersii e 11.531,2 ± 1.054,9 células/mm2 em P. patagoniensis), assim como a proporção dos diferentes tipos de cones (3% cones S e 83% cones L/M em P. olfersii, e 5% cones S e 85% cones L/M em P. patagoniensis). As densidades de células da CCG também foram semelhantes (10.117,5 ± 1.026 células/mm2 em P. olfersii e 9.834,9 ± 2.772,2 células/mm2 em P. patagoniensis). Entretanto, os mapas de isodensidade mostraram diferentes regiões de especialização. P. olfersii apresentou uma faixa horizontal e duas areas centralis de maior densidade celular, uma na região central e uma na região caudal, indicando a melhor acuidade visual nos campos de visão frontal e lateral, o que possivelmente auxilia na locomoção e forrageamento no extrato arbóreo. P. patagoniensis apresentou maior densidade celular na região ventral e rostral, indicando a maior acuidade no campo visual superior e posterior, auxiliando na percepção da aproximação de predadores e animais maiores, importante para a sobrevivência de serpentes terrestres e possivelmente para a percepção de presas localizadas em estrato arbustivo. / Snakes are a diversified group found in almost all regions of the planet, occupying different habitats, with exception to Polar Regions, a few islands and the deeper ocean waters. Its diversity indicates the high variability of sensory organs, which are adapted to the habits and habitats of each species. Studies about snakes visual system are scarce and have a great importance for the understanding of their ecology, behavior and phylogeny. In vertebrates the visual information is projected in the retina and initially processed in this neural tissue, before its processing in the central nervous system. The different kinds of cells present, as well as its density and distribution in the retina, vary between species and determinate specializations of the visual system. In this study we compared the density and distribution of photoreceptors and neurons of the ganglion cells layer (GCL) of two diurnal colubridae snakes, the arboreal Philodryas olfersii and the terrestrial P. patagoniensis, with opsins immunohistochemistry and Nissl staining. Adult snakes obtained in Instituto Butantan were anesthetized with thiopental (30mg/Kg) and the euthanasia was done with CO2. The eyes were enucleated and the retinas dissected and fixed in paraformaldeid 4%. One eye of each species was sectioned to test different antibodies and the counting for the determination of topographic distribution of density was made in flattened wholemount retinas. In the wholemounts retinas it was utilized the antibodies JH455 produced in rabbit against human S cone opsins and JH492 produced in rabbit against human L/M cone opsins. The photoreceptors density were similar in the two species (11,1831 ± 1,107.4 cells/mm2 in P. olfersii and 11,531.2 ± 1,054.9 cells/mm2 in P. patagoniensis), as well as the proportion of the different types of cells (3% S cones and 83% L/M cones in P. olfersii, and 5% S cones and 85% L/M cones in P. patagoniensis). The GCL cells density were also similar (10,117.5 ± 1,026 cells/mm2 in P. olfersii and 9,834.9 ± 2,772.2 cells/mm2 in P. patagoniensis). However, the isodensity maps showed different specializations regions. P. olfersii showed a horizontal streak and two areae (area centralis) with higher density, in the central and in the caudal regions, indicating a better visual acuity in the lateral and in the frontal visual field, what is possibly very important for locomotion and searching for preys (foraging) in the arboreal layer. P. patagoniensis showed a higher cell density in the ventral and rostral regions of the retina, indicating a better visual acuity in the superior and posterior visual field, what is important to perceive the approaching of predators and terrestrial animals and preys located in underbushes above the snake.
92

Propriedades espaço-temporais da acuidade vernier no córtex visual humano usando potenciais visuais provocados de varredura

Marina von Zuben de Arruda Camargo 26 March 2012 (has links)
Esta pesquisa pretendia estabelecer um mapa espaço temporal das respostas de vernier no córtex visual humano. O uso do potencial visual provocado de varredura (PVPv) proporciona medidas eficientes e sensíveis dos limiares de vernier com os quais se pode começar a examinar as respostas corticais de vernier no âmbito dos parâmetros espaço temporais. As respostas de vernier foram avaliadas em relação à hipótese de que os sinais retinianos provenientes das células ganglionares da via magnocelular e não da via parvocelular compõem o input neural para córtex que é utilizado para gerar as respostas de vernier (tarefas de localização de alta precisão Lee et a., 1990; Lee et al., 1995). Métodos: As respostas de vernier no córtex humano foram medidas por meio do potencial visual provocado de varredura (PVPv). Quebras de vernier foram introduzidas em grades de ondas quadradas de produzindo colunas verticais intercaladas de barras estáticas e móveis. Medidas binoculares da acuidade vernier foram feitas em grades de alto contraste (64%) em função de 3 frequências temporais (3, 6 e 15 Hz) e 2 frequências espaciais (1 e 8 c/g). Medidas utilizando grades de baixo contraste foram feitas em função de 3 frequências temporais (3, 6 e 10Hz) e 3 frequências espaciais (1, 2 e 8c/g) em ambos os protocolos (alto e baixo contraste) as medidas foram feitas utilizando o PVPv. Foi utilizado o sistema POWER DIVA que utiliza a metodologia dos mínimos quadrados recursivos para extrair a amplitude e fase da resposta nos harmônicos selecionados da frequência do estímulo. Foram analisados o primeiro (1F1) e o segundo (2F1) harmônicos neste estudo. Com base em estudos anteriores, assume-se que o primeiro componente harmônico refere-se às respostas ao estímulo de vernier, e o segundo às respostas ao movimento relativo dos elementos do estímulo. Esta hipótese foi testada por meio da utilização de protocolos controle para ambos os arranjos de estímulos (alto e baixo contraste) em que foram utilizados os mesmos parâmetros, porém com deslocamentos entre as barras completamente simétricos (elementos da grade jamais se alinhavam). O sistema POWER DIVA calcula para cada segundo de janela de análise (bin) a amplitude local. A amplitude média do ruído nos 10 bins de análise é utilizada para calcular a razão sinal ruído para cada bin. Apenas sinais com razão sinal ruído maior que 3 foram considerados resposta. A média vetorial de 8 tentativas para cada condição de estímulo foi utilizada para determinar os limiares.Resultados: Os dados são consistentes com dados psicofísicos anteriores, especialmente os dados de Bradley & Skottun (1987) que demonstraram decréscimo significativo nos limiares de vernier com o aumento da frequência espacial. Os limiares eletrofisiológicos de vernier obtidos com o presente trabalho mostraram-se paralelos aos dados psicofísicos em função das frequências espaciais em ambos os protocolos. Os limiares no 1F1 também demonstraram redução significativa com o aumento da frequência temporal em altas frequências espaciais / The research was directed at establishing a spatiotemporal map of human cortical vernier responses. The use of swept-parameter, steady state visual evoked potential (sweep VEP, or sVEP) provides efficient and sensitive measurement of vernier thresholds with which to begin to examine cortical vernier responses over the spatio-temporal parameter space. The vernier responses were evaluated in relation to the hypothesis that the magnocellular (M) but not parvocellular (P) ganglion cell retinal output forms the neural input to cortex that is used to derive vernier (high precision localization task - Lee et al., 1990; Lee et al., 1995). Methods: Human cortical vernier responses were measured using the sweep visual evoked potential (sVEP). Vernier offsets are introduced into a square wave grating producing interleaved vertical columns of moving and static bars. Binocular measurements of the vernier acuity were made using high contrast (64%) gratings as a function of 3 temporal frequencies (TF = 3, 6 and 15 Hz) and 2 spatial frequencies (SF = 1 and 8 c/g). Measurements were also made at low contrast (8%) as a function of 3 temporal frequencies (3, 6 and 10Hz) and 3 spatial frequencies (1, 2 and 8c/g) using the sVEP. The POWER DIVA system uses the recursive least squares to extract the response amplitude and phase at selected harmonics of the stimulus frequency. We analyzed the evoked potentials at the first (1F1 fundamental) and second (2F1) harmonics. Based on prior research, we take the 1F1 component to be the specific response to the periodic vernier onset/offset, while the 2F1 component reflects local relative motion responses. We checked this assumption by also measuring sVEPs using a motion control protocol in which equivalent displacement amplitudes were presented in and identical stimulus array, but with the displacements being completely symmetrical alternations between two states of misalignment (grating elements were never aligned). To ensure that the amplitude data used for the regression and extrapolation to threshold is really a response to stimulus instead of noise, POWER DIVA calculates, for each 1-second analysis window (time bin), a local noise amplitude. The mean noise amplitude across 10 analysis bins is used to calculate the signal to noise ratio for each time bin. Only signals with a signal to noise ratio > 3 were considered as a response. The vector average of at least 8 trials was used to determine thresholds. Results: The data are consistent with some comparable prior psychophysical data, especially data from Bradley & Skottun (1987) who showed significant decrease in the vernier thresholds with the increase of spatial frequency. Our cortical (sVEP) vernier thresholds paralleled the psychophysical data as a function of SF in both protocols. The 1F1 (vernier) thresholds also exhibited a significant decrease with increase of temporal frequency at high SF
93

Relação entre o Questionário de Função Visual Infantil e as medidas psicofísicas de acuidade visual e visão de cores em crianças com deficiência visual / Relationship between the Children\'s Visual Function Questionnaire and psychophysical measures of visual accuity and chromaticity discrimination in visually impaired children

Marcia Caires Bestilleiro Lopes 19 September 2014 (has links)
O Questionário de Função Visual Infantil (QFVI) é um instrumento para medir o impacto da deficiência visual na criança e em seus familiares. Pode ser utilizado como ferramenta para pesquisas, verificação da eficácia de tratamentos e de diferentes terapêuticas aplicadas, além de auxiliar métodos que intervenham com melhor eficiência, como habilitação e reabilitação visual. O objetivo deste trabalho é estudar a relação entre os domínios Saúde Geral, Saúde Geral da Visão, Competência, Personalidade, Impacto familiar e Tratamento, que compõem o QFVI, e as medidas psicofísicas de acuidade visual (AV) e discriminação de cromaticidade (VC). Este estudo prospectivo, transversal foi realizado no Laboratório de Psicofisiologia Sensorial da Universidade de São Paulo em parceria com o Ambulatório de Estimulação Visual Precoce Setor de Baixa Visão e Reabilitação Visual da Universidade Federal de São Paulo. As crianças convidadas a participarem deste estudo foram alocadas em 2 grupos: Grupo estudo (GE) composto por 32 crianças, com o diagnóstico de deficiência visual, com idade média de 30 meses (dp= 22,3); Grupo controle (GC) composto por 21 crianças, com visão normal e idade média de 34 meses (dp= 26,8). Esses grupos foram submetidos a aplicação do QFVI, e em seguida as avaliações de medida de AV através do teste de Cartões de Acuidade de Teller (CAT), e VC pelo programa Cambridge Colour Test para crianças (CCT Kids). O resultado da aplicação do QFVI, para os grupos de crianças menores de 3 anos, comparados entre os GE e GC, mostrou diferenças significantes entre os seguintes domínios: Saúde Geral da visão (F=24,07 e p<0,001); Competência (F=73,00 e p<0,001); Personalidade (F=10,21 e p=0,010); Impacto Familiar (F=35,30 e p<0,001); Total da qualidade de vida (F=64,06 e p<0,001). No teste de AV pelo CAT, nos grupos de crianças menores de 3 anos, comparados entre os GE e GC, foram observadas diferenças entre: AV de olho direito (OD) (F=12,86 e p<0,001); AV de olho esquerdo (OE) (F=11,09 e p<0,001); AV de ambos os olhos (AO) (F=16,27 e p<0,001). Estas diferenças mostram uma pior pontuação para o GE. Na VC medidos pelo CCT kids, os dados coletados nos grupos de crianças menores de 3 anos, comparados entre os GE e GC, não foram observadas diferenças estatisticamente significativas para os grupos Protan, Tritan, e Deutan para AO. Na aplicação do QFVI, os dados coletados nos grupos de crianças maiores de 3 anos, comparados entre os GE e GC, foram observadas diferenças entre os seguintes domínios: Saúde Geral da visão (F=10,00 e p<0,001); Competência (F=7,03 e p=0,030); Personalidade (F=6,48 e p=0,010); Total da qualidade de vida (F=11,39 e p=0,010). Estas diferenças mostram uma pior pontuação para o GE. No teste de AV pelo CAT, os dados coletados nos grupos de crianças maiores de 3 anos, comparados entre os GE e GC, foram observadas diferenças entre: AV de OD (F=19,25 e p<0,001); AV de OE (F=25,99 e p<0,001); AV de AO (F=15,45 e p<0,001). Estas diferenças mostram uma pior pontuação para o GE. No teste de VC pelo CCT kids, os dados coletados nos grupos de crianças maiores de 3 anos, comparados entre os GE e GC, não foram observadas diferenças estatisticamente significativas para os grupos Protan, Tritan, e ou Deutan. Para o GE, de crianças menores de 3 anos, a correlação negativa entre as funções visuais e o QFVI, está presente entre as seguintes variáveis: Saúde geral da visão e competência. Já para as crianças maiores de 3 anos: Saúde geral da visão, competência, impacto familiar e total da qualidade de vida. Nós concluímos que existem diferenças estatisticamente significativas quando comparados os GE e GC para as funções de acuidade visual e discriminação de cromaticidade, evidenciando a correlação no uso do QFVI e as funções de AV e VC / The Children\'s Visual Function Questionnaire (CVFQ) is an instrument to measure the impact of visual impairment in children and their families. It can be used as a research tool to verify the effectiveness of treatment, therapy and different methods for the visual stimulation and rehabilitation. The aim of this study is to describe the relationship between General Health, General Vision Health, Personality, Family Impact and Treatment subscales of the CVFQ, and psychophysical measures of visual acuity (VA) and chromaticity discrimination (CV). This prospective, cross-sectional study was conducted at the Sensory Psychophysiology Laboratory - University of São Paulo in partnership with the Ambulatory of Visual Stimulation in Sector of Low Vision and Visual Rehabilitation - Federal University of São Paulo. The children who participated in this study were divided into two groups: study group (SG) composed of 32 children with a diagnosis of visual impairment, mean age of 30 months (sd = 22.3); Control group (CG) consisted of 21 children with normal vision and mean age of 34 months (sd = 26.8). Both groups underwent the application of CVFQ, were tested for VA using the Teller Acuity Cards (TAC) test, and CV by the Cambridge Colour Test program for children (Kids CCT). The result of applying the CVFQ to groups of children under three years, when comparing SG and CG, showed significant differences in the following subscales: General Vision Health (F = 24.07, p <0.001); Competence (F = 73.00, p <0.001); Personality (F = 10.21, p = 0.010); Family Impact (F = 35.30, p <0.001); Total quality of life (F = 64.06, p <0.001). In the VA test by the TAC in groups of children under three years, comparing SG with CG, differences were observed in VA right eye (RE) (F = 12.86, p <0.001); VA left eye (LE) (F = 11.09, p <0.001); VA both eyes (BE) (F = 16.27, p <0.001). These differences show a worse score for the SG. In the CV measured by Kids CCT, the data collected in groups of children under three years, comparing SG and CG, no statistically significant differences for protan, tritan and deutan groups were observed for BE. In applying the CVFQ, the data collected from groups of children over three years, comparing SG and CG, differences were observed in the following subscales: General Vision Health (F = 10.00, p <0.001); Competence (F = 7.03, p = 0.030); Personality (F = 6.48, p = 0.010); Total quality of life (F = 11.39, p = 0.010). These differences show a worse score for the SG. In the VA test by the TAC, the data collected in groups of children over three years, comparing SG and CG, differences were observed in: VA RE (F = 19.25, p <0.001); VA LE (F = 25.99, p <0.001); VA BE (F = 15.45, p <0.001). These differences show worse score for the SG. In the CV by Kids CCT, the data collected in groups of children over three years, comparing SG and CG, no statistically significant differences for protan, tritan and deutan groups were observed. For the SG, children under three years, a negative correlation between the visual functions and the CVFQ was present for the following variables: General Vision Health and Competence, while for children over three years, correlations were found for General Vision Health, Competence, Family Impact and General Quality of Life. We conclude that there are statistically significant differences when comparing the SG with the CG for the visual function of VA and CV, and we also demonstrated the sensitivity in the use of CVFQ in reflect VA and CV impairments
94

Efeitos da desnutrição proteica na percepção de contraste e acuidade visual em humanos e em ratos / Not informed by the author

Caroline Dias da Costa Alencar 29 September 2014 (has links)
O objetivo do presente estudo foi avaliar o efeito da desnutrição proteica em humanos e em modelo animal por meio de medidas comportamentais e bioquímicas. Participaram desse estudo 60 crianças com idade de 7 a 10 anos, sendo 20 eutróficas (grupo controle, GC), 20 com desnutrição atual (grupo experimental atual, GEa) e 20 com desnutrição pregressa (grupo experimental pregresso, GEp). Esses três grupos foram replicados em modelo animal, sendo cada grupo composto por 6 ratos wistar. A acuidade visual (AV) e a sensibilidade ao contraste (SC) foram medidas por meio do método psicofísico em humanos (experimento I) e em ratos (experimento II). Para a medida comportamental com animais foi desenvolvido o Labirinto de Imagens. As análises bioquímicas foram realizadas por meio da técnica de imunohistoquímica e de morfometria da retina de 5 animais de cada grupo (experimento III). Os resultados dos testes comportamentais em humanos e em animais mostraram prejuízos no desempenho dos grupos desnutridos, principalmente no GEp, mesmo com recuperação nutricional. O Labirinto de Imagens se mostrou uma ferramenta útil para medida de parâmetros visuais em roedores. Entretanto, as análises histológicas não apresentaram diferenças significantes entre os grupos, o que provavelmente se deve ao nível de análise não ser capaz de medir componentes sinápticos, arborização dendrítica ou do sistema de neurotransmissão / Not informed by the author
95

Sensory Capabilities of Polypterus Senegalus in Aquatic and Terrestrial Environments

Znotinas, Katherine January 2018 (has links)
In the amphibious fish Polypterus senegalus, focussing on lateral line, vision and electrosensation, we investigated sensory abilities, their interactions, and changes in their effects on locomotor behaviour between aquatic and terrestrial environments. First, we blocked lateral line, vision, or both, and examined effects on locomotion in both environments. Both senses affected both types of locomotion. When fish could see but not feel, variation in several kinematic variables increased, suggesting that sensory integration may affect locomotor control. Next, we assessed response to optokinetic stimuli of varying size and speed. Temporal and spatial visual acuity were both low, as expected in a nocturnal ambush predator. Visual ability in air was much reduced. Finally, we attempted to record electrogenesis in Polypterus, but did not observe the electric discharges reported in a previous study. Future studies might examine changes in sensory function, interaction and importance in behaviour in Polypterus raised in a terrestrial environment.
96

Avaliação da visão funcional infantil em serviço oftalmológico universitário / Functional vision evaluation for children in university ophthalmological service

Zimmermann, Anita, 1959- 22 August 2018 (has links)
Orientadores: Keila Miriam Monteiro de Carvalho, Rodrigo Pessoa Cavalcanti Lira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-22T10:04:39Z (GMT). No. of bitstreams: 1 Zimmermann_Anita_D.pdf: 2614474 bytes, checksum: 1d6ddd4b27c92b25dfed8b28ff8b7940 (MD5) Previous issue date: 2013 / Resumo: Objetivo: Avaliar a Visão Funcional de crianças de zero a 5 anos e 11 meses de idade, após diagnóstico oftalmológico de Baixa Visão, para identificar a necessidade de Estimulação Visual no grupo estudado do Serviço de Estimulação Visual/VSN/OFTALMOLOGIA/HC/FCM/UNICAMP. Materiais e Métodos: Trata-se de estudo transversal analítico, aprovado pelo Comitê de Ética em Pesquisa, nº 1025/2010. Foi utilizado instrumento de Avaliação da Visão Funcional Infantil, organizado após estudos na literatura de autores nacionais e internacionais, na busca por avaliações da visão funcional que contemplassem a necessidade do serviço. Considerando-se as diferentes faixas etárias infantis propostas neste estudo, com n = 143, ponderou-se sobre a efetividade de algumas avaliações pesquisadas, organizando-se instrumento avaliatório, com tópicos, desenvolvidos de maneira a se obter respostas visuais eficientes para determinar condutas em Estimulação Visual. O Instrumento de Avaliação da Visão Funcional Infantil foi aplicado em grupo controle, com mesmo n (n=143) para sua validação. Resultados: As afecções oftalmológicas, responsáveis pelas deficiências visuais do grupo estudado foram: Retinopatia da Prematuridade, Afecções de Nervo Óptico, Deficiência Visual Cortical, Coriorretinite Macular Infecciosa, Malformações Oculares, Catarata Infantil, Degenerações Primárias da Retina, Glaucoma Congênito, Ceratopatias e Trauma Ocular ou Orbitário. A distribuição por idades foi determinada pela proximidade de respostas visuais esperadas para cada faixa etária deste estudo. Em relação ao Desenvolvimento Neuro Psico Motor (DNPM), 44 (30%) crianças apresentavam Bom desenvolvimento Neuro Psico Motor (BDNPM) e 99 (70%) Retardo no Desenvolvimento Neuro Psico Motor (RDNPM). No grupo controle, 2 crianças (1,4%) apresentaram RDNPM. Após aplicação do Instrumento de Avaliação da Visão Funcional Infantil, Parte 1 e Parte 2 (Teste com Cartões de Teller), das 143 crianças estudadas, 107, representando 74% do total, receberam indicação para Estimulação Visual. No grupo controle, independente do DNPM, nenhuma criança recebeu indicação para estimulação visual. Conclusão: O Instrumento de Avaliação da Visão Funcional Infantil, em sua composição com o teste com Cartões de Teller, foi eficiente para determinar condutas em estimulação visual / Abstract: Objective: To evaluate the Functional Vision in children between zero and 5 years and 11 months old, after ophthalmological diagnosis of Low Vision, in order to identify the necessity of Visual Stimulation in the studied group from the Visual Stimulation Service/VSN/OPHTHALMOLOGY/HC/FCM/UNICAMP. Materials and Methods: This is a transversal analytical study, approved by the Research Ethics Committee, nº 1025/2010. It was used an Instrument for Functional Vision Evaluation for Children, organized after studies in the literature of national and international authors, in the search for functional vision evaluations which addressed the need for the service. Considering the different infant ages proposed on this study, with n = 143, the effectiveness of some evaluations surveyed were pondered, resulting in the organization of an evaluation instrument, with topics, developed in order to obtain efficient visual answers to determine Visual Stimulation conducts. The Instrument for Functional Vision Evaluation was applied in the Control Group, with similar n (n=143) for its validation. Results: The ophthalmologic diseases, responsible for the visual deficiencies of the studied group were: Retinopathy of Prematurity, Optical Nerve Disorder, Cortical Visual Deficiency, Infectious Macular Chorioretinitis, Ocular Malformations, Child Cataract, Retinal Primary Degenerations, Congenital Glaucoma, Ceratopatias and Ocular or Orbital Trauma. The age distribution was determined by the proximity of visual responses expected for each group age on this study. Regarding to the Psycho Neuro Motor Development (PNMD), 44 (30%) of the children presented Good Psycho Neuro Motor Development (GPNMD) and 99 (70%) presented Retardation of Psycho Neuro Motor Development (RPNMD). After the application of the Instrument for Functional Vision Evaluation for Children, Part 1 and Part 2 (Test with Teller Cards), on the 143 evaluated children, 107, representing 74% of the total, received indication for Visual Stimulation. In the control group, independently from the PNMD, no children has received indication for visual stimulation. Conclusion: The Instrument for Functional Vision Evaluation for Children, in its composition with the Test with Teller Cards, was efficient to identify conducts in Visual Stimulation / Doutorado / Ciencias Biomedicas / Doutora em Ciências Médicas
97

Desempenho da leitura em pacientes com glaucoma e acuidade visual de 20/20 / Reading performance in glaucoma patients with 20-20 visual acuity

Guimarães, Aron Barbosa Caixeta, 1984- 26 August 2018 (has links)
Orientadores: Keila Miriam Monteiro de Carvalho, Vital Paulino Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T23:17:16Z (GMT). No. of bitstreams: 1 Guimaraes_AronBarbosaCaixeta_M.pdf: 3821530 bytes, checksum: ac0531c33178347f86a1927a76e2ce56 (MD5) Previous issue date: 2015 / Resumo: Investigar a influência dos defeitos do campo visual (CV) no desempenho de leitura de pacientes com glaucoma primário de ângulo aberto (GPAA) e 20/20 de acuidade visual. Métodos: Realizou-se um estudo transversal em 35 pacientes com GPAA e 35 controles pareados por idade, todos com 20/20 de acuidade visual em pelo menos um dos olhos. Os indivíduos foram submetidos à biomicroscopia com lâmpada de fenda, tonometria de aplanação, gonioscopia, exame do nervo óptico com uma lente de 78 dioptrias e perimetria computadorizada com Humphrey Field Analyzer (Sita Standard 24-2). A velocidade de leitura monocular foi avaliada usando-se a tabela Minnesota Low Vision Reading Test (MNREAD) em uma versão traduzida e validada para o português. No grupo dos pacientes com glaucoma, caso ambos os olhos fossem elegíveis, o olho com maior defeito de CV, representado pelo menor Mean Deviation (MD) foi incluído. No grupo controle o olho participante foi escolhido aleatoriamente. Os parâmetros obtidos através do MNREAD foram a Velocidade Máxima de Leitura (VML), o Tamanho Crítico de Letra (TCL) e a Acuidade de Leitura (AL). Resultados: A média da VML nos pacientes com glaucoma (125,04 ± 38,36 palavras por minuto) foi significativamente menor do que no grupo controle (183,95 ± 15,54, p = 0,001). A média do TCL nos pacientes (0,09 ± 0,16 palavras por minuto) foi significativamente maior do que no grupo controle (-0,01 ± 0,07, p = 0,003). A média da AL nos pacientes (-0,17± 0,07) não apresentou diferença estatisticamente significativa em relação ao grupo controle (-0,19 ± 0,07, p = 0,469). A VML apresentou uma correlação positiva muito forte com MD nos pacientes com glaucoma (r = 0,954, p = 0,01). TCL teve uma correlação negativa muito forte com MD no grupo dos pacientes (r = -0,827, p = 0,01). AL apresentou uma correlação negativa substancial com MD no grupo dos pacientes (r = -0,624, p = 0,01). No grupo controle verificou-se correlação negativa baixa entre VML e MD (r = -0,132, p = 0,449), correlação negativa ínfima entre AL e MD (r = -0,076, p = 0,664) e uma correlação negativa moderada entre TCL e MD (r = -0,375, p = 0,026). Conclusões: Pacientes com glaucoma e acuidade visual 20/20 apresentam um comprometimento no desempenho de leitura que se relaciona com a gravidade do defeito no CV / Abstract: To investigate the influence of visual field defects on the reading performance of patients with primary open-angle glaucoma (POAG) and 20/20 visual acuity. Methods: This was a Cross-sectional study of 35 POAG patients and 35 age-matched controls, all with 20/20 visual acuity in at least one eye. All individuals underwent slit-lamp biomicroscopy, applanation tonometry, gonioscopy, optic nerve examination with a 78-D lens and automated perimetry performed with the Humphrey Field Analyzer (Sita Standard 24-2). Monocular reading speed was assessed using the Minnesota Low Vision Reading chart (MNREAD) in a translated and validated Portuguese version. In the patient group, if both eyes were eligible, the eye with more advanced visual field defect, characterized by the lowest Mean Deviation (MD), was included. Only one eye of each healthy participant was randomly included in the study. The parameters obtained with the MNREAD were Maximum Reading Speed (MRS), Critical Print Size Size (CPS) and Reading Acuity (RA). Results: Mean MRS in the POAG group (125.04 ± 38.36 words per minute) was significantly lower than in the control group (183.95 ± 15.54; p = 0.001). Mean CPS in the POAG group (0.09 ± 0.16 words per minute) was significantly larger than in the control group (-0.01 ± 0.07; p = 0.003). Mean RA in the POAG group (-0.17 ± 0.07) showed no statistically significant difference from the control group (-0.19 ± 0.07, p = 0.469). MRS presented a very strong positive correlation with visual field MD in the POAG group (r = 0.954, p = 0.01). CPS presented very strong negative correlation with MD in the POAG group (r = -0.827, p = 0.01). RA presented a substantial negative correlation with MD in the POAG group (r = -0.624, p = 0.01). MRS presented a weak negative correlation with visual field MD in the control group (r = -0.132, p = 0.449). RA presented a very weak negative correlation with visual field MD in the control group (r = -0.076, p = 0.664). CPS presented a moderate negative correlation with visual field MD in the control group (r = -0.375, p = 0.026). Conclusions: Glaucoma patients with 20/20 visual acuity show impairment in reading performance that correlates with the severity of the visual field defect / Mestrado / Oftalmologia / Mestre em Ciências Médicas
98

Variación de la función visual y calidad de vida en pacientes con cataratas antes y después de la Facoemulsificación con colocación de lente intraocular en Lima-Perú

Luján Paredes, Silvio Augusto 20 January 2016 (has links)
Objetivo: Determinar la variación de la función visual y calidad de vida en pacientes con cataratas antes y después de la facoemulsificación más colocación de LIO. Métodos: Estudio longitudinal en pacientes mayores de 50 años, intervenidos de catarata con la cirugía de facoemulsificación con colocación de LIO. Se evaluó la variación de la función visual con el VFQ 25 y la calidad de vida con el QOL.Q 40 antes de la intervención quirúrgica y luego de 3 meses. Resultados: La edad media de los pacientes fue de 74 años ± 7,4, 55%, de los cuales 37,5% tuvieron una cirugía previa de cataratas. Se evidenció una variación favorable de la función visual en las subescalas de Salud general (p<0,001), Visión General (p< 0,001), Visión de cerca (p= <0,001), Visión de lejos (p< 0,001), Limitaciones (p= 0,001) y Visión Periférica (p< 0,001). La calidad de vida medida con el QOLQ.40, también presentó cambio favorable evidenciándose una diferencia significativa en la subescala de Satisfacción con un (p=0,0001.). Se calculó la correlación entre la variación de la función visual medida con el VFQ 25 y la variación del número de células endoteliales, hallando una mejora en la subescala de “Limitación” con un rho de Spearman de 0.3456. Conclusión: Los pacientes presentaron respuesta favorable a la intervención tanto a nivel clínico, observando un incremento de la agudeza visual, como en la función visual y calidad vida. Los cuestionarios de calidad de vida son adaptables a nuestra población, su uso permitirá una medición integral de los resultados de la cirugía. / Tesis
99

Computerized Dynamic Visual Acuity with Volitional Head Movement in Patients with Vestibular Dysfunction

Johnson, Erika L 25 March 2002 (has links)
Patients with non-compensated vestibular dysfunction frequently complain of the ability to maintain dynamic visual acuity during activities which require the movement of the head. When this occurs the patient is experiencing oscillopsia, which is the symptom resulting from a non-functional vestibulo-ocular reflex (VOR). To measure the presence of oscillopsia, tests of dynamic visual acuity (DVA) may be used. A recent test of DVA has been reported which is administered while patients are walking on a treadmill. Although this test has been shown to be useful in evaluating DVA in patients, there are several disadvantages to treadmill use. These include physical space, cost and accessibility. Additionally, walking at the required treadmill speed to produce sufficient head movement may pose difficulties and be medically contraindicated for patients with certain health risks. The purpose of this study was to evaluate a different method to measure DVA in patients which would not require the use of the treadmill, but instead utilize a volitional head movement to reveal oscillopsia. In this study, patients performed the DVA test in two conditions: (1) walking on a treadmill, and (2) seated on a chair volitionally moving the head. In this study, DVA was tested in both conditions with 15 adults with normal vestibular function, and 16 adults with vestibular impairment. Results revealed that both methods, treadmill walking and volitional head movement, appeared equivalent for measuring DVA in normal subjects and vestibular impaired subjects. The lack of finding a significant main effect of method, and interactions that include method, supports the equivalence of volitional head movement to a treadmill approach for the measurement of DVA.
100

Third Case of Candida Dubliniensis Endogenous Endophthalmitis in North America: Case Report and Review of the Literature

Rosenberger, Elizabeth, Youssef, Dima A., Safdar, Sara, Larzo, Cristoforo R., Myers, James 01 January 2014 (has links)
There are two previous reports of Candida dubliniensis endophthalmitis in North America. Here, we report a third case of C. dubliniensis endogenous endophthalmitis in a 31-year-old male patient who complained of left-sided decreased visual acuity. He had an associated mitral and tricuspid valve endocarditis, in the setting of intravenous drug use. Blood and sputum cultures were positive for C. dubliniensis. Fundoscopic examination was consistent with a fungal endophthalmitis. He was treated with fluconazole followed by intravenous liposomal amphotericin B for 6 weeks. C. dubliniensis is an important but rare cause of endophthalmitis in intravenous drug abusers.

Page generated in 0.0505 seconds