• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69760
  • 32926
  • 15219
  • 13396
  • 2687
  • 2618
  • 2189
  • 2185
  • 2185
  • 2185
  • 2185
  • 2185
  • 1857
  • 1037
  • Tagged with
  • 48678
  • 43758
  • 19526
  • 13657
  • 9599
  • 9334
  • 7881
  • 6951
  • 6787
  • 6194
  • 6182
  • 5971
  • 5366
  • 4426
  • 4374
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Samtidighet i elektriske bygningsinstallasjoner / Simultaneity in electrical building installations

Johansen, Thomas Aleksander January 2013 (has links)
Undersøkelser har vist at belastningen av bygg ikke stemmer med forventet forbruk, og det antas at store installerte effekter står ubrukt. Hvordan installasjonene kompenserer for samtidighetene i belastningen, og hvordan påvirker samtidigheten forbruket og samtidighetsfaktorene i installasjonen? Fire konkrete yrkesbygg ble sett på for å undersøke tilstandene, kontorbygget Nordregate 8, bank- / kontorbygget SpareBank1, sykehjemmet Munkvoll HSV og Rosenborg Skole.Strømmålinger gjort på installasjonene ble utført over tid for å kartlegge forbruket inn til fordelingene og ut på kursnivå. Man måtte velge ut noen kurser å studere nøye på grunn av begrensninger i utstyret. Effektmålinger ble utført momentant på alle kursene for å finne effektfaktorene for belastningene i fordelingene.Resultatene viste at samtidigheten på kursnivå varierte mellom belastningen kursene forsyner. Stikkontakter til uspesifisert bruk ble målt til å ha de laveste gjennomsnitts samtidigheter med 0,1655, belysningskursene 0,2631, varmekursene 0,5138 og diverse spesifikk belastning ble målt til 0,6292. Uspesifiserte stikkontaktskurser sin lave samtidighet var som forventet, og man så de samme resultatene fra målingene gjort i fordypningsprosjektet høsten 2012 [1]. Resultatene fra belysningskursene var overaskende, siden disse har en mer kontinuerlig belastning. Bedre kontroll på installerte effekter er eneste mulighet til å unngå denne typen overdimensjonering.Samtidighetsberegningene for belastningen på inntaket viste meget forskjellige samtidigheter mellom yrkesbyggene. Rosenborg kom ut lavest og hadde maksimal samtidighet på 0,1230, Sparebank1 0,1344, Nordregate 8 0,4559 og Munkvoll 0,9413. Rosenborg og SpareBank1 er begge nye installasjoner med energieffektive belastninger. Begge fordelingene har en stor del stikkontaktskurser med lavest samtidighet av belastningsgruppene sett på. Overraskelsen var nok størst for resultatene i Munkvoll, som viste meget høy samtidighet på fordelingen. Dette var den eneste installasjonen med topografisk inndeling av kursene, og stor bruk av trefase kurser. Det kan virke som Munkvoll er underdimensjonert.Å sette riktig samtidighetsfaktorer viste seg å være komplisert. Der er flere faktorer å ta med i betraktningene, men det viktigste man må ta for seg er å bestemme de installerte belastningene. Planleggernes motivasjon for å effektivisere sluttresultatet blir ofte overskygget av risikoene for å underdimensjonere installasjonene. Besparingsmulighetene er store, og man så i flere tilfeller at man kunne halvert antall kurser og installert effekt, uten å overbelaste vernene med samme belastning.
22

Seriefeilvern i elektriske installasjoner / Series Fault Protection in Electrical Installations

Larsson, Carl Olav January 2012 (has links)
Seriefeil, dvs. overgangsmotstand i kontaktpunkter, har i lang tid vært en fremtredende brannårsak i norske bygninger, og er en av de hyppigste brannårsakene i elektriske anlegg. På grunn av begrensninger i tilgjengelige løsninger for deteksjon av seriefeil på det norske markedet, er det hittil ikke blitt stilt krav til seriefeilvern i Norge. Andre land har imidlertid begynt å stille krav til slike vern. Hovedmålet med denne oppgaven var derfor å undersøke om det finnes løsninger for deteksjon av seriefeil på markedet, hvilke krav andre land stiller til slike vern og hvilke løsninger for deteksjon av seriefeil som finnes i de land som stiller til krav seriefeilvern.Denne rapporten presenterer flere løsninger for deteksjon av seriefeil, som enten allerede finnes på det norske markedet eller gjøres tilgjengelig innen kort tid. Det er derfor ikke mangelen på tilgjengelige løsninger som begrenser muligheten for å installere disse produktene i norske elektriske anlegg. Det foreslås derfor at tilsynsmyndighetene vurderer å anbefale installasjon av seriefeilvern i norske elektriske installasjoner, slik det gjøres i bl.a. USA, for å redusere antall branner med elektrisk årsak.Rapporten presenterer laboratorieforsøk hvor det ble undersøkt hvilke temperaturer som kan oppstå i reelle elektriske installasjoner med skjult installasjonsmetode, under både normale forhold og ved elektriske feil. Forsøkene undersøkte også funksjonaliteten til et seriefeilvern, kalt Electric Temperature Increase Monitoring, og hvor mye den termiske isolasjonen i veggen influerer temperaturutviklingen i koblingspunktene. Seriefeilvernet var kun en prototype på det tidspunktet det ble testet. Resultatene fra forsøkene gav følgende konklusjoner:- Hovedproblemet med seriefeil i elektriske installasjoner er sannsynligvis hovedsakelig glødende kontaktforbindelser, og ikke serielysbue. Begrunnelsen for dette ble basert på observasjoner foretatt under forsøk med regulerbare gap, hvor det var vanskelig å opprettholde en strømbegrenset lysbue over lang tid ved 230 V AC.- Ved forskriftsmessig utførelse kan det oppstå temperaturer på 55,3 °C i koblingspunkt i løpet av 5 timer. Ledertemperaturen var sannsynligvis noe høyere, og dermed nær lederisolasjonens temperaturgrense på 70 °C. - Ved kontaktsvikt ble det for alle forsøkene registrert temperaturer over lederisolasjonens temperaturgrense. Forsøk på 2,5 mm2 ledertverrsnitt medførte temperaturer på 94,3 °C ved 15,5 A, og 131,9 °C ved 17,5 A belastningsstrøm. - Høye belastningsstrømmer i kombinasjon med dårlig kontaktforbindelse medførte større skader på installasjonsmateriellet, og det konkluderes derfor med at denne typen elektrisk feil i høyeste grad kan være brannfarlig.- Det ble kun observert mindre temperaturforskjeller ved ulik grad av termisk isolasjon.- Seriefeilvernet som ble undersøkt fungerte hensiktsmessig, både under normale forhold og ved elektriske feilkilder i kretsen.
23

Hurtiglading av elbil - Energilagring / Fast charging of electrical vehicles - Energy storage

Skjelbred, Håkon Berg January 2014 (has links)
Oppgaven tar for seg en problemstilling knyttet til hurtigladestasjoner for elbiler og problemer dette kan gi for overføringsnettet. I nett hvor tilkobling av slike ladestasjoner er problematisk kan lokal lagring brukes til å redusere effekttopper og dermed være et alternativ til tiltak i nettet. I rapporten er det kartlagt problemer med tung belastning av nett i sammenheng med hurtigladestasjoner. Videre er det gjort greie for teori om lagringsmedier og ladestasjoner, samt noen tekniske vurderinger av et system med lokal lagring. Det er gjort målinger ved en hurtigladestasjon av typen CHAdeMO, plassert på NTNU Gløshaugen. Strømflyt ved forsyningen til ladestasjonen er logget for å kartlegge bruken av stasjonen, samt skaffe data til senere bruk i simuleringer og analyser. Videre ble det avlest harmonisk forstyrrelse i spenning og strøm ved stasjonen. Resultatene viser at den harmoniske forstyrrelsen ved denne stasjonen er lav, THDU ble målt til 0,7-0,8% og THDI ble målt til omkring 6%. Dette er helt uproblematiske verdier med hensyn på krav som er satt i Forskrift for Leveringskvalitet (FoL). Grunnene til disse lave verdiene antas å være et sterkt og godt dimensjonert nett, godt dimensjonerte transformatorer og eventuelt bruk av andre tiltak, som filtre, til å redusere den harmoniske forvrengingen. Det er gjort to forskjellige simuleringer i oppgaven. En dynamisk analyse er gjort i SIMULINK, samt lastflytanalyser i MATPOWER. Begge programmer er basert på matematikkprogrammet MATLAB. Den dynamiske analysen skal simulere et eksempel på hvordan samspillet mellom nettforsyning, batteri og hurtigladestasjon kan se ut. I lastflytanalysene er to forskjellige systemer analysert. Et er bygget opp med utgangspunkt i fordeling fra nettstasjonen som forsyner hurtigladestasjonen på Gløshaugen. Det andre systemet er fiktivt og skal representere et nettsystem i et mindre sentralt område. Av simuleringene ble det gjort følgende bemerkelser:•Lokal lagring er ikke egnet i systemet på Gløshaugen. Grunnen er at nettet i området allerede er sterkt og godt dimensjonert, som resulterer i at en tilknytting av batterier ved lasten gir lite utslag i spenningsverdier i noder og tap i linjer. •Det fiktive nettet viser tydeligere påvirkningen lokal lagring kan ha på nettet. I systemet stiger eksempelvis spenningen i noden med lavest verdi med 0,039 p.u ved installasjon av lokal lagring, tilsvarende en spenningsøkning på 8,97 V. Videre reduseres tapene ved maks last med 1,81% med batterier tilkoblet. Det må understrekes at systemet med størst påvirkning av lokal lagring er fiktivt, og resultatene kan ikke brukes til å trekke endelige slutninger. Etter å ha sett på egne målinger og målinger gjort av Sintef, samt samtaler med andre som har innsikt i tematikken, er den generelle oppfatningen av dagens utbygging av hurtigladestasjoner at de er godt planlagt med tanke på nett og nettbelastning. Samtidig ser man at med dagens salg av ladbare biler vil det i årene som kommer kreves omfattende utbygging av infrastruktur for elbiler, deriblant hurtigladestasjoner. Strategiske plasseringer med hensyn på rekkevidde, mye brukte veistrekker og tilgjengelighet blir viktigere. En god nettforsyning kan i større grad bli nedprioritert som et avgjørende kriteria. Alternative løsninger for problematikk knyttet til for tung belastning av nett vil høyst sannsynlig bli enda mer sentralt i årene som kommer, og oppgaven har vist indikasjoner på at lokal lagring ved hurtigladestasjoner kan være et høyst aktuelt alternativ.
24

Eco-efficient supply chains for electrical and electronic products = Eco-efficiënte aanbod ketens voor elektrische en elektronische produkten /

Quariguasi Frota Neto, Joâo. January 2008 (has links)
Diss. Univ. Rotterdam, 2008. / Mit niederländischer Zusammenfassung.
25

Quality nonconformity data management in electrical motor manufacturing

Alatulkkila, S. (Simo) 05 December 2018 (has links)
Quality management can be an important success factor for organisations. With effective quality management, companies can increase their productivity, reduce quality nonconformities and as a result, improve their profitability. One key aspect in quality management is the management of quality nonconformities. Nonconformities are important learning opportunities and effective management of them can help companies strive towards better quality. This thesis was done for ABB Motors & Generators in Vaasa and the goal was to find ways to improve quality nonconformity data management in the case company. This thesis was completed as a qualitative case study. At first, a literature review covering quality management, quality nonconformity management and quality nonconformity data management was conducted. Secondly, semi-structured interviews were performed inside the case company to understand the current situation, requirements and problems within the case company. Then, benchmarking visits were done to four companies from different industries in order to understand the best practices of quality nonconformity data management. Lastly, nonconformity data was analysed from the nonconformity database of the case company. As a result, improvements were proposed for the quality nonconformity data management inside the case company. Requirements for data collection were defined and data collection framework was created based on that. In addition, new categorisation model for quality nonconformities was developed. Furthermore, two reporting tools were designed and implemented to increase and develop information-sharing about quality problems. These tools facilitate quality communication and the development of quality reporting and metrics. The practical results of this study are mostly case-specific and are not fully applicable outside the case company. However, the field of quality nonconformity data management is not studied extensively, so this study can be taken as a general guideline on how to organise quality nonconformity data management in a mass customization production environment. / Laadunhallinta ja laatujohtaminen voivat olla tärkeitä menestystekijöitä yrityksille. Tehokkaalla laadunhallinnalla yritykset voivat tutkitusti lisätä tuottavuuttaan, vähentää laatupoikkeamien määrää ja parantaa kannattavuuttaan. Laatupoikkeamien hallinta on tärkeä osa laadunhallintaa. Laatupoikkeamat ovat hyvä mahdollisuus oppia ja poikkeamien tehokas eliminointi ja hallinta voi johtaa huomattaviin parannuksiin yrityksen laatutasossa. Tämä diplomityö on tehty ABB:n moottorit ja generaattorit -yksikköön Vaasassa ja sen tavoitteena on kehittää kohdeyrityksen laatupoikkeamadatan hallintaa. Tämä diplomityö on kvalitatiivinen case-tutkimus. Tutkimuksen kirjallisuuskatsauksessa käsiteltiin laadunhallinnan, laatupoikkeamienhallinnan ja laatupoikkeamadatan hallinnan pääkohdat. Empiirisessä osuudessa toteutettiin teemahaastattelut kohdeyrityksen henkilöstölle. Haastattelujen tavoitteena oli kartoittaa kohdeyrityksen nykytila, vaatimukset ja ongelmat laatupoikkeamadatan hallinnan suhteen. Tämän jälkeen toteutettiin benchmarking-haastattelut neljään yritykseen eri toimialoilta. Benchmarkingin avulla kartoitettiin alan parhaita käytäntöjä. Haastattelujen lisäksi tutkimuksessa käytettiin kohdeyrityksen keräämää dataa laatupoikkeamatietokannasta. Työn tuloksena saatiin kehitysehdotuksia kohdeyrityksen laatupoikkeamadatan hallintaan. Datan keräämisen vaatimukset määriteltiin ja niiden pohjalta luotiin malli datan keräämisen kehittämiseksi. Lisäksi laatupoikkeamille luotiin uusi luokittelumalli, joka edesauttaa tärkeimpien poikkeamatyyppien tunnistamista. Tiedonkulun ja kommunikaation kehittämiseksi työssä suunniteltiin ja toteutettiin kaksi raportointityökalua, jotka edesauttavat laatuun liittyvää kommunikaatiota sekä raportoinnin ja laatumittareiden kehittämistä kohdeyrityksessä. Työn käytännön tulokset eivät enimmäkseen ole sovellettavissa kohdeyrityksen ulkopuolelle. Teoreettisesta näkökulmasta työn tuloksia voidaan kuitenkin käyttää ohjenuorana massaräätälöityjä tuotteita valmistavan yrityksen laatupoikkeamadatan hallintaan.
26

Electrical and thermal applications of carbon nanotube films

Mäklin, J. (Jani) 28 March 2014 (has links)
Abstract Carbon nanotubes (CNTs) have fascinating mechanical, electrical and thermal properties, all of which significantly depend on structural properties such as nanotube length, number of walls, lattice defect densities, impurities and surface functional groups. A number of different applications of carbon nanotubes have been demonstrated during the past two decades including electrical interconnects, transistors, heating and cooling devices, sensors and various actuators. However, further studies on the structure-dependent properties and innovative handling techniques of these materials are needed in order to explore the limitations of use and to be able fully to exploit the advantageous properties of such one-dimensional sp2 hybridized carbon nanomaterials. In this thesis, random networks of single-wall and multi-walled carbon nanotubes (SWCNTs and MWCNTs, respectively) and aligned films of multi-walled carbon nanotubes are studied in the context of three main application fields: gas sensing, electrical interconnects/electrodes and thermal cooling elements. Analyses of associated material properties and some feasible integration techniques are discussed. Single-wall and multi-walled carbon nanotube films cast from aqueous dispersions are shown to be selective nitric oxide sensing components in Taguchi-type sensor devices, in which films based on SWCNTs outperformed those made of MWCNTs. The thickness dependent electrical conduction mechanism of inkjet-printed SWCNT films is also discussed. Robust aligned MWCNT films are demonstrated as soft electrical contact brushes in DC motors and in other moving electrical contacts. The thermal properties of freestanding aligned MWCNT forests are analyzed and shown to be potential alternatives to copper or aluminium in the thermal management of electrical components. / Tiivistelmä Hiilinanoputkien kiehtovat mekaaniset, sähköiset ja lämmönjohto-ominaisuudet ovat kiinnostaneet tutkijoita suuresti viimeisten kahden vuosikymmenen ajan. Monia erilaisia applikaatioita on demonstroitu tänä aikana: mukaan lukien sähköiset kontaktit, transistori-rakenteet, lämmitys- ja jäähdytyslaitteet, anturirakenteet sekä erilaiset aktuaattori-rakenteet. Tämän väitöskirjan päätavoitteena on tutkia hiilinanoputkien toiminnollisuutta ja käytännöllisyyttä erilaisissa sovelluskohteissa. Tässä työssä käytettävät hiilinanoputkirakenteet ovat joko satunnaisjärjestyksessä olevia nanoputkista koostuvia verkostorakenteita tai yhdensuuntaisia, makroskooppisia hiilinanoputkikalvoja. Nanoputkia tutkitaan kolmessa erityyppisessä sovelluskohteessa: kaasuanturisovelluksessa, sähköisissä kontaktirakenteissa sekä jäähdytyselementteinä. Työssä analysoidaan hiilinanoputkirakenteiden ominaisuuksia eri sovelluskohteissa sekä esitetään joitain käyttökelpoisia tekniikoita hiilinanoputkien integroimiseen olemassa oleviin tekniikoihin. Hiilinanoputkien osoitetaan olevan käyttökelpoisia aktiivisia materiaaleja typpioksidille resistiivisessä kaasuanturirakenteessa. Tulosten perusteella yksiseinämäiset hiilinanoputket ovat moniseinämäisiä herkempiä ja parempia kyseisessä sovelluksessa. Lisäksi tutkitaan ja analysoidaan mustesuihku-tulostettujen yksiseinämäisten hiilinanoputkifilmien sähköisten ominaisuuksien riippuvuutta filmin paksuudesta. Vantterien yhdensuuntaisten moniseinämäisten hiilinanoputkirakenteiden osoitetaan toimivan erinomaisesti pehmeinä sähköisinä kontaktielementteinä liikkuvissa sähköisissä kontakteissa. Vapaasti seisovien yhdensuuntaisten, moniseinämäisten hiilinanoputkirakenteiden lämmönjohto-ominaisuuksien tutkiminen ja analysointi osoittaa, että kyseisiä rakenteita voidaan käyttää tehokkaina jäähdytyselementteinä ja mahdollisesti korvaavana vaihtoehtona alumiinille ja kuparille sähköisten komponenttien lämmönhallinta sovelluksissa.
27

ELECTRICAL STIMULATION OF THE FROG'S RETINA.

KNIGHTON, ROBERT WILLIAM January 1973 (has links)
DISSERTATION (PH.D.)--THE UNIVERSITY OF MICHIGAN
28

The Approximation problem of electrical filters /

Amer, Roshdi Abdel-Rahman. January 1964 (has links)
Diss. Math. ETH Zürich, Nr. 3399, 0000. Ref.: Stiefel, E. ; Korref.: Läuchli, P. / SA aus: Mitteilungen aus dem Institut für angewandte Mathematik an der ETH, Nr.9, S.1-64.
29

Electrical characterization of transition metals in silicon:

Scheffler, Leopold 19 June 2015 (has links) (PDF)
The understanding of the electrical properties of defects introducing deep levels in silicon is of prime technological importance in modern microelectronics. In this thesis, a comprehensive study of the transition metals titanium, cobalt, and nickel in silicon, and of their interaction with hydrogen is presented. The formed defects are detected and characterized by deep level transient spectroscopy (DLTS), Laplace DLTS, and minority carrier transient spectroscopy. A natural starting point for a study of metal-hydrogen reactions in silicon is the analysis of the effect of hydrogen on metal-free silicon. Complexes of hydrogen with carbon, which create deep levels in the band gap of silicon, are observed. Titanium introduces three levels into the band gap. The charge states determined in this thesis are in contradiction to the literature, questioning the assignment of these levels. Upon hydrogenation, TiH complexes with one, two, and three hydrogen atoms are identified. A proposition by theory that two different configurations of TiH with one hydrogen atom exist, can be supported. Cobalt is shown to have only one level in the band gap of silicon, whereas a second level previously attributed to cobalt is assigned to the cobalt-boron pair. Two CoH complexes are determined. Nickel has three levels in the band gap. Upon hydrogenation, complexes with up to three hydrogen atoms are identified. One of the defects can be observed in both n - and p -type silicon. For all three metals investigated, passive hydrogen complexes exist. They are created by further hydrogenation after the appearance of the above mentioned electrically active complexes. The thesis concludes with a comparison of the obtained results with those of neighboring elements to look for similarities and patterns. / Das Verständnis der elektrischen Eigenschaften von Defekten, welche tiefe Niveaus in der Bandlücke von Silizium erzeugen, ist von außerordentlichem Interesse für die moderne Mikroelektronik. In der vorliegenden Dissertation wird eine umfassende Untersuchung der Übergangsmetalle Titan, Kobalt und Nickel in Silizium und ihrer Wechselwirkung mit Wasserstoff vorgestellt. Die entstandenen Defekte werden mit Hilfe von Kapazitätstransientenspektroskopie (DLTS - deep level transient spectroscopy), Laplace DLTS und Minoritätsladungsträgertransientenspektroskopie (MCTS - minority carrier transient spectroscopy) beobachtet und charakterisiert. Für eine fehlerfreie Analyse der Metall-Wasserstoff-Reaktionen ist es sinnvoll, zuerst den Einfluss des Wasserstoffs auf metallfreies Silizium zu prüfen. Dabei wird die Bildung von Kohlenstoff-Wasserstoff-Komplexen, welche Niveaus in der Bandlücke von Silizium erzeugen, beobachtet. Titan besitzt drei Niveaus in der Bandlücke von Silizium. Die in dieser Arbeit bestimmten Ladungszustände stehen im Widerspruch zu den Literaturangaben, daher wird die Zuordnung dieser Niveaus in Frage gestellt. Die Reaktion von Titan mit Wasserstoff führt zu elektrisch aktiven Komplexen mit bis zu drei Wasserstoffatomen. Die Ergebnisse unterstützen einen Vorschlag aus der Theorie, nach dem der Komplex mit einem Wasserstoff zwei verschiedene Konfigurationen besitzen soll. Kobalt erzeugt ein Niveau in der Bandlücke. Ein weiteres Niveau, welches früher ebenfalls dem Kobalt zugewiesen wurde, kann dem Kobalt-Bor-Paar zugeordnet werden. Nach der Reaktion mit Wasserstoff können zwei CoH-Komplexe nachgewiesen werden. Nickel besitzt drei Niveaus in der Bandlücke und erzeugt elektrisch aktive NiH-Komplexe mit bis zu drei Wasserstoffatomen. Einer dieser Defekte kann sowohl im n - als auch im p -Typ Silizium beobachtet werden. Alle drei untersuchten Metalle besitzen elektrisch passive Komplexe, welche nach der weiteren Reaktion von Wasserstoff mit den aktiven Komplexen entstehen. Die Arbeit endet mit einem Vergleich der Ergebnisse mit denen benachbarter Elemente, um mögliche Ähnlichkeiten oder Muster zu erkennen.
30

ELECTRICAL EQUALIZATION FOR MULTIMODE FIBER SYSTEMS

Liu, Yizhou 11 January 2017 (has links)
No description available.

Page generated in 0.187 seconds