• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 457
  • 336
  • 88
  • 64
  • 50
  • 20
  • 14
  • 13
  • 10
  • 9
  • 8
  • 5
  • 4
  • 4
  • 3
  • Tagged with
  • 1269
  • 687
  • 250
  • 162
  • 97
  • 91
  • 73
  • 72
  • 67
  • 67
  • 64
  • 63
  • 63
  • 61
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
731

Estimação do diâmetro e rugosidade em um processo de furação utilizando multi sensores e redes neurais artificiais /

Cruz, Carlos Eduardo Dorigatti. January 2010 (has links)
Orientador: Paulo Roberto de Aguiar / Banca: José Alfredo Covolan Ulson / Banca: Alisson Rocha Machado / Resumo: A crescente competitividade do mercado, exigência por qualidade, padronização cada vez superior a necessidade de redução do desperdícios trazem cada vez mais a automação às indústrias. Por suas características, os processos automatizados podem ser melhorados com a utilização de métodos de controle e supervisão e, neste campo, a utilização de sensores e redes neurais artificiais têm cada vez mais destaque em pesquisa. No processo de furação, estudos relatam a aplicação bem sucedida destas técnicas na determinação do fim da vida de ferramentas, contudo, em muitas aplicações, apenas o controle do desgaste da broca não é suficiente para garantir a qualidade do produto. Diâmetro do furo usinado, rugosidade e a formação de rebarbas são alguns exemplos de importantes resultados do processo que não dependem exclusivamente da condição da ferramenta de corte, neste âmbito, estudos dedicados ao controle destas variáveis são limitados, senão inexistentes. Desta forma, este estudo foi conduzido buscando gerar uma contribuição à supervisão do processo de furação com foco na estimação do diâmetro e rugosidade do furo usinado. Utilizando um sistema multi sensores instalados em uma máquina ferramenta e corpus de prova compostos por uma liga de titânio seguida de uma liga de alumínio, registraram-se os sinais dos sensores durante o corte para variados parâmetros de usinagem. Os dados coletados serviram de entrada a uma rede neural artificial, que foi treinada com os valores de diâmetro e rugosidade medidos parte das amostras. Depois do treinamento, a rede capacitou-se a estimar os valores de diâmetro e rugosidade média a partir dos sinais coletados somados aos parâmetros de corte utilizados na concepção do furo. Os erros dos processo foram então calculados da diferença entre os valores medidos e as saídas obtidas. Os resultados demonstraram alta capacidade da rede em determinar as viariáveis desejadas / Abstract: The growing market competitiveness, product quality requirements and just in time production concept is bringing every time more automation to manufacturing industries. Productivity and quality in machining process can be improved by using monitoring and controlling methods. Along the last decades, sensors and Artificial Neural Network have been successfully utilized in many drill wear monitoring systems. However, in many industrial fields, to supervise the tool wear is not enough to assure the product qualities. Roughnessm burr formation and hole diameter are some examples of important process results does not exclusively depend on the tool condition and in this area of knowledge the number of studies is limited or inexistent. Thus, this work brings a contribution on drilling process monitoring where the target was to determine the hole diameter and roughness using a multi-sensor system and artificial neural network. The speciments used were composed by a titanium alloy and aluminum alloy plates. The sensors were installed in a machine tool and the process was accomplished using several drilling parameters. The acquired sensors data were used a input in an artificial neural network which was trained with the roughness and diameter measured in some samples. After trained, the system was qualified to output the expected variables from the input signals. To calculate the errors these output values were compared with the samples measured. The results showed efficiency of the system in determining the roughness and hole diameters as the obtained errors can be considered low or neigligible for the majority of drilling industrial application / Mestre
732

Propriedades e adesão de cimentos de ionômero de vidro modificados por resina e vitrocerâmicas bioativas / Properties and adhesion of glass ionomer cements modified by resin and bioactive glass-ceramic

Fagundes, Ticiane Cestari 17 February 2009 (has links)
As vitrocerâmicas bioativas são materiais sintéticos capazes de aderirem quimicamente aos minerais presentes na estrutura dentária. A união dos cimentos de ionômero de vidro modificados por resina (CIVMRs) à dentina pode ser influenciada por diferentes tipos de tratamentos prévios à restauração. Os objetivos deste estudo foram: avaliar a resistência à compressão, a rugosidade e a adesão à dentina de CIVMRs (Fuji II LC e Vitremer) após a incorporação de partículas de vitrocerâmicas bioativas (Biosilicato®); foi ainda, avaliar a resistência à degradação da adesão à dentina dos CIVMRs, utilizando-se EDTA como pré-tratamento dentinário. Para o teste de resistência à compressão foram confeccionados cilindros sendo que 2, 5 e 10 % em peso de partículas de vitrocerâmica bioativa foram incorporadas aos pós dos CIVMRs, armazenados em água destilada por 24h a 37°C até a realização dos testes. A rugosidade dos cimentos experimentais (2% de vitrocerâmica bioativa) e controles foi avaliada por microscopia de força atômica (MFA) após armazenamento a seco e em 100 % de umidade por 1 mês. Para os testes de microtração, as superfícies das cavidades foram tratadas seguindo-se as instruções dos fabricantes ou utilizando-se EDTA. Os espécimes foram restaurados com os CIVMRs experimentais (2% de vitrocerâmica) e controles. Após as restaurações, os espécimes foram armazenados em água por 24h e 7d. Para o teste de degradação, os CIVMRs foram armazenados por 24h, 3m e imersos em 10% de hipoclorito de sódio por 5h. Os dentes foram seccionados em palitos e submetidos ao teste de microtração. ANOVA e teste de múltiplas comparações foram realizados (p<0,05). O modo de fratura foi classificado em adesivo, misto e coesivo e alguns espécimes foram analisados em microscopia eletrônica de varredura (MEV). Apenas os cimentos com 2% de vitrocerâmica bioativa obtiveram resistência a compressão semelhante ao grupo controle. Para os grupos controles, Fuji II LC apresentou-se mais rugoso que o Vitremer e o seu armazenamento à seco aumentou sua rugosidade. A condição de armazenamento, seco ou úmido, não afetou a rugosidade dos CIVMRs experimentais. A vitrocerâmica bioativa aumentou significantemente a adesão à dentina dos CIVMRs após armazenamento por 24h, exceto para o Fuji II LC quando EDTA foi utilizado. A aplicação de EDTA aumentou significantemente os valores de resistência adesiva. No estudo de degradação da união, valores de resistência adesiva significantemente maiores foram obtidos nos grupos onde a dentina foi pré-tratada com EDTA. A resistência adesiva do Fuji II LC à dentina não foi afetada pelos métodos de degradação utilizados. Valores de resistência adesiva significantemente menores foram observados para os espécimes restaurados com Vitremer após os dois métodos de degradação, exceto quando a dentina foi prétratada com EDTA. As falhas do tipo mistas foram prevalentes. Em conclusão, 2% de partículas de vitrocerâmica bioativa podem ser incluídas nos CIVMRs sem afetar suas propriedades mecânicas. A rugosidade dos CIVMRs experimentais não foi afetada pelo meio de armazenamento. A inclusão de vitrocerâmicas bioativas aumentou a resistência adesiva somente após armazenamento de 24h. A utilização de EDTA como pré-tratamento dentinário aumentou a resistência adesiva para todas as condições e preveniu a degradação da interface adesiva do Vitremer. / Bioactive glass-ceramics are synthetic materials capable of chemically bonding to dental structures. Adhesion of resin-modified glass-ionomer cements (RMGICs) to dentin may be influenced by different types of dentin pre-treatments. The objective of this study was to analyze the compressive strength, roughness and adhesion to dentin of RMGICs (Fuji II LC and Vitremer) after the incorporation of bioactive glassceramic particles (Biosilicate). Additionally, the durability of the RMGICs adhesion was analyzed after the application of EDTA as a pre-treatment of dentin. Cylinders of RMGICs with incorporation of 2, 5 and 10 % in weight of bioactive glass-ceramic particles were made for compressive strength, and stored in water for 24h at 37°C. Roughness of control and experimental (2% bioactive glass-ceramic) RMGICs was analyzed by atomic force microscopic (MFA) after storage in dry and humidity conditions for 1 month. For the microtensile test, the surfaces of the cavities were treated following the manufacturers instructions or by applying EDTA. The cavities were restored with control and experimental (2% bioactive glass-ceramic) RMGICs. After restorations, the specimens were stored in water for 24h and 7 days. For the degradation test, the RMGICs were stored for 24h, 3 months or immersed in 10% NaOCl for 5h. Teeth were sectioned in beams and submitted to microtensile test. ANOVA and multiple-comparisons tests were used (p<0.05). Mode of failure was classified in adhesive, mixed and cohesive, some specimens were analyzed by scanning electronic microscopic. Only the RMGICs with 2% of bioactive glassceramic obtained compressive strength similar to the control RMGICs. The storage conditions, dry or humidity, did not affect the roughness of experimental RMGICs. Bioactive glass-ceramic significantly increased the adhesion to dentin of RMGICs after storage for 24h, except for Fuji II LC when EDTA was applied. The application of EDTA significantly increased the values of bond strength. For the degradation study, high values of bond strength were also observed in groups where the dentin was pre-treated with EDTA. The bond strength of Fuji II LC to dentin was not affected by the degradation methods. Vitremer specimens presented significantly lower bond strength values after degradation methods, except when EDTA was applied. Mixed failures were the most prevalent in all groups. In conclusion, 2% of bioactive glassceramic particles may be included in RMGICs without affecting their mechanical properties. Roughness of experimental RMGICs was not affected by storage conditions. The incorporation of bioactive glass-ceramic increased the bond strength after storage for 24h. The application of EDTA as a pre-treatment of dentin increased the bond strength for all conditions studied and prevented the degradation of adhesive interface of Vitremer.
733

Avaliação da variabilidade das características geotécnicas relacionadas aos processos erosivos com ensaios in situ / Evaluation of variability of geotechnical characteristics related to erosion processes using in situ tests

Furegatti, Simone Andrea 16 October 2012 (has links)
A inadequada utilização do meio físico tem gerado desequilíbrios ambientais com sérias consequências socioeconômicas, por vezes de proporções desastrosas, como é o caso das feições erosivas encontradas em vários estados do país. No estado de São Paulo, somente na região entre as cidades de São Pedro e Corumbataí (SP) ocorrem milhares de feições erosivas de portes variados. Os estudos sobre erosão têm apresentado resultados diversos em função de aspectos como a variabilidade das informações consideradas, a diversidade e pequeno número de pesquisas com validação espacial e temporal e a falta de continuidade e detalhamento dos estudos. Os modelos de previsão de erosão existentes mensuram e avaliam principalmente a quantidade de sedimento gerado por erosão laminar. É possível observar a inexistência de modelos que considerem os processos envolvidos na incisão e permanência de erosões lineares, ou que forneçam uma previsão de ocorrência desse tipo de erosão. A complexidade e dificuldade de obtenção de dados para alimentar e validar um modelo estão entre as principais justificativas do baixo número de tentativas de desenvolvimento de modelos de erosão linear. A presente tese buscou identificar e gerar dados de variáveis envolvidas nos processos erosivos lineares e analisar a variabilidade espacial e temporal dos resultados. Adicionalmente, foi avaliada a dificuldade de obtenção de tais dados. Ensaios de caracterização geotécnica, resistência à penetração dinâmica, taxa de infiltração e erodibilidade do solo foram empregados para esse fim. O levantamento da rugosidade do terreno e ensaios com simulador de chuva foram utilizados para a determinação de valores de escoamento superficial e geração de sedimento. Os ensaios com simulador de chuva promoveram, ainda, a observação da ocorrência de incisões no terreno e do processo erosivo. Como resultado obtiveram-se séries de dados para alimentar um modelo de erosão linear. Optou-se por tratar os dados como uma distribuição aleatória e utilizar a ferramenta estatística de análise de variância, a ANOVA, para comprovar a igualdade significante dos valores obtidos. Dentre as respostas obtidas a partir dos resultados, destaca-se a comprovação da dificuldade em gerar dados para alimentar um modelo de erosão, principalmente de obter dados de incisão no solo, para validar um possível modelo de erosão linear. Em uma área que possui um determinado material geológico, em geral, a variabilidade dos dados de caracterização do solo mostrou-se pequena. E a resistência do solo à penetração, por sua vez, apresentou grande variabilidade em função da umidade do solo. / Inappropriate use of physical environment has led to an environmental imbalance with serious social and economic consequences. In many cases, such as erosive features found in several Brazilian States, these problems reached disastrous proportions. Thousands of erosive features with different sizes and depths can be found between the municipalities of São Pedro and Corumbataí, in São Paulo State, Brazil. Researches regarding erosion processes in this region have provided inconclusive results due to aspects related to data variability, and lack of both researches with reliable validation and continuity of studies. Current erosion prediction methods are mainly concerned with the amount of sediment resulted from laminar erosion processes. In addition, prediction models for linear erosion processes are rarely reported in technical literature, mainly due to their complexity and difficulty of obtaining reliable validating data. In this regard, the objective of this study is to identify the variables involved in linear erosion processes and build a database with these parameters in order to analyze both spatial and temporal distribution of such phenomenon. As a secondary objective, the difficulty of collecting data was evaluated. Field and laboratory tests were performed in this research, including geotechnical characterization, dynamic penetration test, infiltration rate and erodibility tests. Besides, a rain simulator was developed and used in field tests to cause an erosive process. These observations combined with characteristics of terrain roughness allowed the determination of both runoff and infiltration amounts. As a result, it was possible to provide validation data to a linear erosion prediction model. Data was evaluated as a random distribution using a statistical tool for variance analysis (ANOVA). Among the results, it is important to notice the difficult to collect reliable data to be used in validation of a linear erosion model, mainly those related with the soil incision. Areas with the same soil cover have presented similar data variability referred to soil characterization. On the other hand, penetration resistance values were found to be highly dependent on the soil water content.
734

Avaliação da superfície do esmalte após diferentes tempos de jateamento de óxido de alumínio indicados para a colagem de braquetes / Evaluation of enamel surface after different times of aluminium oxide sandblasting indicated for bracket bonding

Gabarrone, Lilian Rocha 01 July 2016 (has links)
Objetivo: avaliar e comparar os efeitos do jato de óxido de alumínio sobre a superfície do esmalte, quando aplicados por tempos diferentes. Material e métodos: 110 pré-molares foram obtidos por meio de doações do Banco de Dentes da FOUSP. Os dentes foram divididos aleatoriamente em 5 grupos (n=22) para a aplicação de jato de óxido de alumínio por diferentes períodos de tempo. Nos grupos A, B, C, D e E o jato de óxido de alumínio de 50 ?m foi aplicado, respectivamente, por 01, 03, 05, 07 e 10 segundos. Avaliações quantitativas da superfície do esmalte foram realizadas pelas análises das alterações do perfil e da rugosidade (Sa) da superfície vestibular antes e após o seu jateamento, por meio do medidor de perfil Form Talysurf Intra (Taylor Hobson - AMETEK Inc, Pennsylvania) e do interferômetro a laser Talysurf CCl Lite (Taylor Hobson - AMETEK Inc, Pennsylvania), respectivamente. Uma avaliação qualitativa da superfície do esmalte foi realizada por meio da microscopia eletrônica de varredura (MEV). Para esta última análise, um exemplar de cada grupo foi selecionado aleatoriamente para que as superfícies de esmalte jateadas fossem devidamente preparadas para as suas leituras. Os dados quantitativos foram comparados pelo teste ANOVA, seguido do teste post hoc de Tukey, adotando-se um nível de significância de 5% (p= 0,05). Resultados: observou-se maior alteração do perfil e da rugosidade conforme se aumentou o tempo de aplicação do jato de óxido de alumínio. Porém, com relação à alteração do perfil, diferenças estatisticamente significantes foram observadas somente entre o grupo A (1s) quando comparado aos grupos D (7s) e E (10s), e entre o grupo B (3s) quando comparado com o grupo E (10s). Quanto à rugosidade, verificou-se diferença estatisticamente significante apenas entre o grupo E (10s) quando comparado aos demais grupos. As cinco imagens obtidas pelo microscópio eletrônico de varredura (MEV) demonstraram bastante semelhança entre si, com padrão de condicionamento marcado por picos e vales, porém as imagens dos esmaltes jateados por 1 e 3 segundos apresentaram esses picos e vales em menor quantidade. Conclusão: a perda de estrutura dentária e a rugosidade da superfície do esmalte aumentaram conforme se aumentou o tempo de aplicação do jato de óxido de alumínio; a aplicação do jato de óxido de alumínio por 1 e 3 segundos promove menos perda de estrutura de esmalte do que quando se jateia o esmalte por 10 segundos; maior rugosidade pode ser obtida com o jateamento de óxido de alumínio por 10 segundos; entretanto, o aspecto morfológico do esmalte dentário é bastante similar, independentemente do tempo de jateamento. / Objective: To evaluate and compare the effects of aluminium oxide sandblasting on enamel surface when applied at different times. Materials & Methods: 110 premolars were obtained from the local tooth bank. The teeth were randomly divided into 5 groups (n = 22) for application of aluminium oxide sandblasting at different times. In Groups A, B, C, D and E, sandblasting with 50-?m aluminium oxide particles was applied for 01, 03, 05, 07 and 10 seconds, respectively. Quantitative assessments of enamel surface were performed by analysing changes in the profile and roughness (Sa) of the buccal surface before and after sandblasting application by using a profile gauge (Form Talysurf Intra, Taylor Hobson - AMETEK Inc, Pennsylvania, USA) and a laser interferometer (Talysurf CCl Lite, Taylor Hobson - AMETEK Inc, Pennsylvania, USA), respectively. A qualitative assessment of enamel surface was performed by means of scanning electron microscopy (SEM). For this latter analysis, a sample of each group was randomly chosen so that the sandblasted enamel surfaces could be adequately prepared to be evaluated. The quantitative data were compared by using ANOVA test, followed by post-hoc Tukey\'s test, at a significance level of 5% (P = 0.05). Results: Profile and roughness were found to be more altered as the sandblasting application time increased. With regard to the profile, however, statistically significant differences were found only in Group A (1s) compared to Groups D (7s) and E (10s), as well as in Group B (3s) compared to Group E (10s). With regard to the roughness, statistically significant difference was also observed only in Group E (10s) compared to the other groups. Five SEM images were demonstrated to be very similar to each other, with the conditioning pattern being marked by peaks and valleys, although SEM images of enamel blasted for 1 and 3 seconds showed peaks and valleys in lesser amount. Conclusion: Both loss of dental structure and enamel roughness increased as the time for application of aluminum oxide sandblasting also increased; application of aluminum oxide sandblasting for 1 and 3 seconds produced less loss of enamel structure compared to the 10-second application; more roughness can be obtained with application of aluminum oxide sandblasting for 10 seconds; however, the morphological aspect of the tooth enamel is very similar, regardless of the application time.
735

Avaliação de cimentos de ionômero de vidro modificados por resina frente à incorporação de nanopartículas de vitrocerâmica bioativa / Resin modified glass ionomer cements evaluation with additional bioactive glass-ceramics nanoparticles

Freitas, Maria Cristina Carvalho de Almendra 31 May 2011 (has links)
Os materiais bioativos são materiais sintéticos que possuem superfícies ativas em que os minerais presentes em tecidos duros podem se ligar quimicamente. Há alguns estudos em Odontologia, onde partículas desses materiais foram incorporadas aos Cimentos de Ionômero de Vidro (CIVs) e Cimentos de Ionômero de Vidro modificados por resina (CIVMRs) com o objetivo de se obter bioatividade, e conseqüente remineralização dentária. O presente estudo teve como objetivo avaliar os efeitos da incorporação de nanopartículas de vitrocerâmica bioativa nas propriedades de resistência à compressão e rugosidade de CIVMRs. Fuji II LC e Vitremer foram considerados os grupos controles. Materiais experimentais foram feitos através da incorporação de 2, 5 e 10% em peso de Biosilicato nestes CIVMRs. Seis corpos-de-prova de cada material foram confeccionados para o teste de resistência à compressão, que foi realizado em máquina de ensaios universal (Emic), a uma velocidade de 1,0 mm/min, depois de mantidos por 24 horas em água destilada a 37°C. Para análise da rugosidade, foram confeccionados dois corpos-de-prova de cada material, armazenados em água destilada por sete dias, para terem suas superfícies analisadas por meio de Microscopia de Força Atômica. Os dados da resistência à compressão e rugosidade foram submetidos à análise estatística por meio da Análise de Variância (ANOVA) a dois critérios e para comparações múltiplas foi aplicado o teste de Tukey, com nível de significância de 5%. Apenas os cimentos com 2% de nanopartículas de vitrocerâmica bioativa obtiveram resistência à compressão semelhante ao grupo controle, as demais concentrações contribuíram para a diminuição dessa resistência. A incorporação de 5% de nanopartículas de vitrocerâmica bioativa aumentou a rugosidade superficial dos CIVMRs estudados. / Bioactive materials are synthetic materials that have active surfaces that are capable to chemically bond to dental structures. There are some studies where particles of these materials were incorporated in Glass-ionomer cements (GIC) and Resin-modified glass-ionomer cements (RMGIC) trying to achieve bioactivity and dental remineralization. The aim of this study was to evaluate the effects of the incorporation of bioactive glass-ceramics nanoparticles on the compressive strength and roughness of RMGIC. Fuji II LC and Vitremer were considered the control groups. Experimental materials were made adding 2, 5 and 10% (weight) of Biosilicate into these RMGIC. Six specimens of each material were made to be tested on compressive strength performed with a universal testing machine (Emic) at a crosshead speed of 1.0 mm / min, after they were stored in distilled water for 24 hour at 37°C. To roughness analysis, two specimens of each material were made and stored in distilled water for 7 days and their surfaces were analyzed with a Atomic Force Microscope. Data of compressive strength and roughness were statistically analyzed by ANOVA and Tukey test for multiple comparisons. Only the RMGICs with 2% of bioactive glass-ceramic nanoparticles obtained compressive strength similar to the control RMGICs, the other concentrations decreased their compressive strength values. The incorporation of 5% of bioactive glass-ceramic nanoparticles increased the roughness of the RMGICs.
736

Medida de rugosidade por correlação angular de speckle / Measure of roughness by angle speckle correlation

Borbely, Luiz Alberto 18 January 2005 (has links)
Esse trabalho apresenta o método de correlação angular de speckle. Esse método foi melhorado para ser aplicado na medição de rugosidade na faixa de 30 m a 0,1 m. Um programa de computador foi desenvolvido para processar imagens e calcular a correlação angular, e novas fórmulas matemáticas foram deduzidas. / This work presents the speckle pattem angular correlation method. This method was improving to be applicable in the roughness measuring in the range of 0,1 m to 30 m. A software was developed to process image and to calculate the angular correlation, and new mathematical equations were formulating.
737

Comportamento mecânico, resistência de união e longevidade de pilares e coroas de zircônia obtidas por sistema CAD-CAM: influência de diferentes tratamentos de superfície / Mechanical behavior, bond strength and reliability of YTZP abutments and crowns processed by CAD/CAM: The role of surface treatments

Dantas, Talita Souza 29 April 2015 (has links)
O objetivo do estudo foi avaliar a resistência de união à zircônia após diferentes tratamentos de superfície e o comportamento mecânico de pilares e coroas de zircônia associados aos mesmos tratamentos. Na primeira fase, 95 discos em zircônia foram obtidos e divididos em cinco grupos (n = 19): GC (grupo controle, sem nenhum tipo de tratamento); GAL (jateamento com partículas de Al2O3 antes da sinterização); GALS (jateamento com partículas de Al2O3 após sinterização); GRO (silanização com sistema Rocatec antes da sinterização) e GROS (silanização com sistema Rocatec após sinterização). Três amostras de cada grupo tiveram a superfície analisada em MEV e MCVL. Dez amostras de cada grupo foram submetidas a ensaio de microcisalhamento e as seis restantes foram submetidas à análise de interface por meio de MEV. A análise estatística utilizou modelo de regressão linear com efeitos mistos e teste de Tukey (p < 0,01). Na segunda fase, 70 pilares do tipo hexágono externo foram obtidos em zircônia e associados a coroas totais com copings de zircônia. Os conjuntos análogo-pilar-coroa também foram divididos em cinco grupos (n=14) e submetidos aos mesmos tratamentos previamente descritos. Ainda, foram realizadas mensurações para verificação da adaptação dos copings sobre os pilares e rugosidade superficial dos discos, copings e pilares em MCVL. Foi realizado ensaio de fadiga mecânica dos conjuntos com carga progressiva de 80, 120, 160, 200, 240, 280 e 320 N, frequência de 5 Hz, totalizando 20.000 ciclos em cada estágio. A ciclagem térmica foi realizada com temperaturas entre 5º C e 55º C. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (probabilidade de sobrevida, teste de Log-Rang, p < 0,05) Os resultados apontaram que o grupo ROS apresentou valores de resistência de união significativamente superiores (p < 0,01) e que a rugosidade superficial foi semelhante para discos e copings (p = 0,22) e para discos e pilares (p = 0,96), e diferente entre copings e pilares (p < 0,01). A desadaptação marginal foi maior para o grupo RO (p < 0,01) e a probabilidade de sobrevida dos conjuntos foi similar para todos os grupos testados (p = 0,57). Concluiu-se que a utilização do Rocatec aumenta os valores de resistência de união à zircônia, não compromete o comportamento mecânico do material e sua utilização é viável em peças já sinterizadas. / The aim of this study was to evaluate the bond strength to zirconia after different surface treatments and to evaluate the mechanical behavior of zirconia abutments and crowns associated with these treatments. In the first phase, 95 discs in zirconia were obtained and divided into five groups (n = 19): GC (control group, without any treatment), GAL (air particle abrasion with Al2O3 particles before sintering), GALS (air particle abrasion with Al2O3 particles after sintering), GRO (silanization with Rocatec system before sintering) and GROS (silanization with Rocatec system after sintering). Three samples of each group had the surfaces analyzed in SEM and CLSM. Ten samples of each group were subjected to microshear test and the other remaining six had their interface examined by SEM. The statistical analysis used a linear regression model with mixed effects and Tukey test (p <0.01). In the second stage, 70 external hex abutments were obtained in zirconia and associated with crowns and zirconia copings. The analog-abutment-crown assemblies were also divided into five groups (n = 14) and subjected to the same treatments described previously. Measurements to verify the adaptation of copings on the abutments and surface roughness of the discs, copings and abutments were performed in CLSM. A fatigue test was carried with progressive load of 80, 120, 160, 200, 240, 280 and 320 N, frequency of 5 Hz and 20,000 cycles at each stage. Thermal cycling was performed with temperatures between 5° C and 55° C. After mechanical tests, the results were subjected to statistical analysis (survival probability, Log-Rang test, p <0.05) The results showed that the ROS group had significantly higher bond strength values (p < 0.01) and that the surface roughness was similar for discs and copings (p = 0.22) and for discs and abutments (p = 0.96), and was different between copings and abutments (p < 0.01). The marginal gap was higher for RO group (p < 0.01) and the survival probability of the sets was similar for all tested groups (p = 0.57). It was concluded that the use of Rocatec increases the bond strength values to zirconia, does not compromise the mechanical behavior of the material and its use is now feasible in sintered parts.
738

Avaliação da alteração de cor e rugosidade média superficial de resinas acrílicas usadas em base de próteses após imersão em desinfetantes químicos e bebidas / Evaluation of the color alteration and superficial roughness of the denture base acrylic resins after immersion in chemical didinfectants and beverages

Fernandes, Flávio Henrique Carriço Nogueira 24 September 2009 (has links)
Pacientes submetidos a procedimento protéticos estão expostos a microorganismos patogênicos podendo ocorrer desenvolvimento de doenças e infecção cruzada entre pacientes e equipe odontológica.As próteses devem ser desinfetadas com substâncias que não provoquem alterações nas propriedades mecânicas e físicas principalmente em associação com a ingestão de bebidas com teor alcoólico ou baixo pH. O objetivo desse estudo foi avaliar a rugosidade média superficial (Ra) e estabilidade de cor de resinas acrílicas(Lucitone 550, QC-20 e Vipi-Wave), empregadas na confecção de bases para próteses totais, removíveis, overdentures e próteses protocolos sobre implantes após imersão em desinfetantes químicos (hipoclorito de sódio 1% e ácido peracético 2%) por 30 e 60 minutos, e após desinfecção por 30minutos seguida de imersão em bebidas com e sem teor alcóolico (vinho, suco de uva, chá e aguardente). Foram confeccionados 60 corpos-de-prova de cada marca comercial de resina, sendo divididos em 2 grupos, referentes aos desinfetantes químicos. Após os procedimentos de acabamento e polimento dos corpos-de-prova, foram realizadas as mensurações iniciais (t=0) de rugosidade e cor, e a seguir dez corpos-de-prova de cada marca comercial de resina foram imersos em hipoclorito de sódio e dez em ácido peracético, durante 30 e 60 minutos, sendo realizadas as mensurações após cada período de imersão. Esses dados foram, posteriormente submetidos à análise estatística. Quarenta corpos-de-prova de cada tipo de resina foram imersos em hipoclorito de sódio e ácido peracético por 30min, a seguir foram realizadas as mensurações de rugosidade e cor, e a divisão em subgrupos referentes às bebidas. Os corpos-de-prova foram lavados com água destilada, secos com lenços de papel e imersos em vinho(n=5), suco de uva(n=5), chá (n=5) e aguardente (n=5) por 2 horas. Após as mensurações, os corpos-de-prova foram imersos em água destilada e mantidos por 24 horas, decorrido esse período foram realizadas as mensurações de rugosidade e cor. Os corpos-de-prova eram imersos diariamente nas bebidas por 2 horas e as mensurações subseqüentes de rugosidade e cor eram realizadas após 168hs (7dias), 336hs (14dias) e 504hs (21dias) de imersão nas mesmas bebidas.Os dados foram analisados estatisticamente pela Análise de Variância e testes complementares de Tukey e Scheffé. Foi evidenciado aumento da Ra após 30 minutos de imersão nos desinfetantes em todas as resinas, com QC-20 apresentando os maiores valores de Ra e Vipi-Wave os menores. Lucitone 550 apresentou maior Ra após imersão em vinho, suco de uva e aguardente e Vipi-Wave após imersão em chá. Após 60minutos de imersão nos desinfetantes todas as resinas apresentaram alteração de cor estatisticamente significante. Os corpos-de-prova imersos em vinho apresentaram os maiores valores de alteração de cor após 336hs (14dias), enquanto os imersos em suco de uva apresentaram alterações de cor leves após 168hs (7dias), 336hs (14dias) e 504hs (21dias), e os imersos em aguardente e chá não apresentaram alterações de cor clinicamente significantes. Conclui-se que desinfecção em hipoclorito de sódio 1% e ácido peracético alterou as propriedades de rugosidade média e cor das resinas avaliadas, e dentre as bebidas, vinho e suco de uva foram as que propiciaram maior alteração de cor. / Patients submitted to prosthetic procedures are exposed to pathogenic microorganisms, and the development of diseases and crossed infection may occur between patients and the dental team. Dentures must be disinfected with substances that do not cause changes in the mechanical and physical properties, particularly in association with the ingestion of beverages with alcohol concentration or low pH. This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC-20 and Vipi-Wave), used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes, and after disinfection, followed by immersion in beverages (wine, grape juice, tea and brandy) for 30minutes. Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. After the test specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, tem test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 sixty minutes, with measurements being taken after each immersion period. Afterwards, these data were submitted to statistical analysis. Forty test specimens of each type of resin were immersed in sodium hypochlorite and peracetic acid for 30 min, after which roughness and color measurements were taken, and specimens were divided into subgroups according to the beverages. The specimens were washed with distilled water, dried with paper towels and immersed in wine (n=5), grape juice (n=5), tea (n=5) and brandy (n=5) for 2 hours. After being measured, the test specimens were immersed in distilled water and kept there for 24 hours. When this period elapsed, roughness and color were measured. The test specimens were immersed for 2 hours daily, and the subsequent roughness and color measurements were taken 168 hrs (7days), 336 hrs (14days) and 504 hrs (21days) after immersion in the same beverages. The data were statistically analyzed by the Analysis of Variance and Tukey and Scheffé complementary tests. There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC-20 presenting the highest Ra values, and Vipi-Wave the lowest. The Lucitone 550 resin presented the highest Ra after immersion in wine, grape juice and brandy, and Vipi-Wave after immersion in tea. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. The test specimens immersed in wine presented the highest color alteration values after 14 days, while those immersed in grape juice presented slight color alterations after 168 hrs (7days), 336hrs (14days) and 504hs (21days), and those immersed in brandy and tea presented no clinically significant color alterations. It was concluded that disinfection in 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the evaluated resins, and among the beverages, wine and grape juice were those that produced the greatest color alteration.
739

Efeito da escovação e enxaguatório bucal na alteração de cor e rugosidade de resinas compostas / Effect of toothbrushing and mouthwash on the color change and surface roughness of composite resins.

Trauth, Keico Graciela Sano 30 July 2010 (has links)
O presente estudo avaliou in vitro a influência de diferentes tipos de enxaguatórios bucais associados com a escovação, na alteração de cor e rugosidade superficial de diferentes tipos de resinas compostas diretas (M1- Filtek Supreme XT, M2- Z100, M3- Ice) por meio do espectrocolorímetro PCB 6807 da BYK-Gradner, rugosímetro modelo SJ-201P Mitutoyo e Microscopia Eletrônica de Varredura. Foram preparados 300 corpos de prova (n=10) para a variável alteração de cor, e destes espécimes 180 (n=6) foram submetidos ao ensaio de rugosidade superficial. Os espécimes foram polidos com discos Soft Lex, na sequência de abrasividade decrescente e armazenados em saliva artificial a 37°(±1°C) até o momento de serem submetidos nas soluções S1- Solução com álcool e com corante, Colgate Plax Fresh Mint; S2- Solução sem álcool e com corante, Oral-B; S3- Solução com álcool e sem corante, Cepacol; S4- Solução sem álcool e sem corante, Colgate Plax e S5- Grupo controle, Saliva Artificial e realização das leituras das variáveis em estudo, nos tempos T0- imediatamente após o polimento, T1- 7dias, T2- 14dias, e T3- 21dias. Todos os espécimes dos grupos experimentais foram imersos sob agitação, nos diferentes enxaguatórios bucais, 1 vez ao dia, por 2 minutos, durante 5 dias na semana. Após a realização de todas as leituras do estudo foram selecionados dois espécimes de maneira aleatória, de cada grupo experimental, totalizando 30 espécimes que foram submetidos a observação por médio de Microscopia Eletrônica de Varredura. Os dados de alteração de cor e de rugosidade superficial para cada uma das resinas, individualmente e para comparação das três resinas submetidas à escovação foram analisados por meio do teste ANOVA e Tukey (p&le;0,05). Os resultados para alteracao de cor mostraram que: o fator Solução foi significante somente para a resina Filtek Supreme XT, sendo a menor média S1 e a maior S3, por outro lado S2, S3, S4 e S5 foram estatisticamente iguais. O fator tratamento escovação foi significante para as resinas M2 e M3, sendo que para M2 a condição CES determinou maior média que SES e para M3, SES foi maior que CES. Para as três resinas o fator Tempo foi estatisticamente significante: a) M1 no T1 a média foi menor que em T2 e T3; b) para M2 a média em T1 foi menor que T2 e maior que T3; c) em M3, T1 foi igual a T2 que por sua vez foram menores que T3. Comparando o comportamento das três resinas constatou-se que M1 e M3 tiveram medias estatisticamente iguais e maiores que M2. Com relação à rugosidade superficial dos materiais M2 e M3, submetidos aos enxaguatórios utilizados neste estudo verificou-se que este fator não teve efeito estatisticamente significante; enquanto que para M1 houve diferença significante, assim, as médias de S1, S2 e S3 foram iguais e menores que as médias de S4 e S5. O fator tratamento escovação teve efeito significante somente para M1 sendo que a condição SES apresentou maior media que a CES. Com relação ao fator tempo verificou-se que para M1, a partir de T1, T2 e T3 as medias foram iguais entre si e maiores que T0; para M2 a maior media foi em T2 havendo igualdade estatística entre T0, T1 e T3; já para M3 as medias em T2 e T3 foram estatisticamente iguais e maiores que T0. Comparando as três resinas M1 apresentou maior rugosidade que M2 e M3 que foram estatisticamente iguais entre si. De acordo com a metodologia utilizada conclui-se que a alteração de cor das resinas estudadas foi influenciada pelo tempo; o tratamento escovação determinou alteração de cor para M2 e M3 e não foram influenciadas pelas soluções em estudo; M2 apresentou menor alteração que M1 e M3. Para rugosidade superficial conclui-se que o fator solução e o fator tratamento foram significantes somente para M1. O fator tempo influenciou a rugosidade das três resinas compostas. Relevância clinica: Há necessidade que o cirurgião dentista conheça as características das resinas compostas a ser utilizada no tratamento restaurador, além dos prováveis efeitos que os enxaguatórios bucais possam ter nas propriedades físicas do material, para assim indicá-los corretamente. / The present study evaluated in vitro the influence of different types of mouthwash associated with brushing, the color change and surface roughness of different types of direct composite resins (M1 - Filtek Supreme XT, M2 - Z100, M3 - Ice) through a PCB 6807 spectrocolorimeter of BYK-Gradner, rugosimeter model Mitutoyo SJ-201P and scanning electron microscopy. 300 specimens (n = 10) for the color alteration variable were prepared; of these, 180 specimens (n = 6) were subjected to tests surface roughness. The specimens were polished with discs Soft Lex (3M), following the decreasing abrasiveness sequence and stored in artificial saliva at 37 ° (±1 ° C) until be submitted in solutions S1 - solution with alcohol and dye, Colgate Plax Fresh Mint; S2 - solution without alcohol and with dye, Oral-B; S3 -solution with alcohol and without dye, Cepacol, S4 - Solution without alcohol and dye, Colgate Plax; S5 - Control Group, Artificial Saliva. The readings of the variables in study occurred in T0 - immediately after polishing, T1 7 days after, T2 14 days after and T3 21 days after. All specimens of the experimental groups were immersed with agitation in the different mouthrinses, once a day, for 2 minutes, during 5 days per week. After performing all readings of the study, two randomly selected specimens were chose from each experimental group, a total of 30 specimens were selected randomly and subjected to observation by scanning electronic microscopy. The data on color change and surface roughness for each resin were analyzed separately and together for comparison across the tests ANOVA and Turkey (p &le; 0.05). The results for color change demonstrated that the factor solution was significant only for Filtek Supreme XT resin, with S1 being the smallest and S3 the largest average. Still, S2, S3, S4 and S5 were statistically equal. The brushing treatment factor was significant for M2 and M3 resins, as the CES (with brushing) condition had a higher average than the SES (without brushing) one for M2; and for M3, SES was higher than CES. For the three resins, the time factor was significant: a) M1 at T1, the average was lower than in T2 and T3, b) to the M2 medium was lower than in T1 and T2 greater than T3, c) in M3, t1 was equal to t2 and both lower than T3. Comparing the behavior of the three resins, it was found that M1 and M3 average were statistically equal and higher than M2. Regarding the surface roughness of materials M2 and M3, submitted to rinses utilized in this study it was found that this factor had no statistically significant effect, while for M1 was significant difference, with the average of S1, S2 and S3 were equal and lower than the averages of S4 and S5. The factor brushing treatment effect was significant only for M1 being that the condition SES had a higher rating than the CES. Regarding the time factor, it was found that for M1, from T1, T2 and T3, the average was equal and higher than T0, for M2, the higher average was in T2, with statistical equality among T0, T1 and T3; for M3 average in T2 and T3 were statistically equal and greater than T0. Comparing the three resins, M1 showed higher roughness than M2 and M3 who were statistically equal. According to the used methodology, concludes that the color change of the resins was influenced by the time; treatment brushing determinate the color change for M2 and M3 and both were not influenced by the solutions under study; M2 showed lowest change than M1 and M3. For surface roughness is concluded that the factor solution and factor treatment were significant only for M1. The time factor influenced the roughness of the three composite resins. Clinical Relevance: It is necessary that dental surgeon know the characteristics of composite resins to be used in restorative treatment, beyond the likely effects that the mouthrinses may have on the physical properties of the material, to have correct indications.
740

Estudo da rugosidade de superfícies planas usinadas por fresas de topo esférico / Roughness study for flat surfaces milling by ball nose tools

Batista, Marcelo Ferreira 19 January 2007 (has links)
Dentro da cadeia produtiva de moldes e matrizes, a usinagem tem o maior peso, considerando tanto os custos envolvidos, quanto o tempo de programação e execução. O emprego das tecnologias CAD/CAM/CNC e HSC atualmente é um atributo básico de competitividade. O que determinará a vantagem estratégica das empresas será o uso otimizado dessas tecnologias. Nos processos de usinagem, o acabamento é uma operação que demanda muito tempo, e muitas vezes não se atinge o resultado desejado, seja por falta de conhecimento dos fenômenos envolvidos na usinagem, seja pelo uso de estratégias de usinagem sem conhecimento detalhado do processo de fabricação. A otimização da etapa de acabamento terá um ganho enorme na repetibilidade da usinagem, uma economia de ferramentas e, principalmente a eliminação de uma etapa, considerando a usinagem do molde/matriz com o material já tratado termicamente com a dureza final de utilização. O objetivo deste trabalho é estudar a usinagem de acabamento de superfícies planas utilizando fresas de topo esférico, demonstrando que os valores teóricos de altura de crista fornecidos pelos softwares CAM não são valores reais. A determinação de fatores ligados à etapa de acabamento de superfícies planas, indicando a melhor alternativa na usinagem do aço ferramenta WNr 1.2367, mostra que os parâmetros de usinagem estudados tiveram grande influência na rugosidade, principalmente o sentido de corte. O conhecimento dos melhores parâmetros de usinagem e suas influências no resultado final, assim como outros fatores, tem o intuito de oferecer informações às empresas e aos seus programadores no sentido de agilizar o planejamento e execução de moldes e matrizes. / In die mould production sequence, the milling is the most important factor, considering both the programming costs and the manufacturing time. In fact, the application of CAD/CAM/CNC and HSC technologies is a basic competitiveness edge. The optimized use of these technologies will determine the strategic advantage for industries. The finishing by milling is a step that spend a long time and, in most cases, the final result is not the desired one. That is a consequence of the lack of knowledge on the involved phenomenon or by the use of milling strategies without the enough knowledge on milling processes. The optimization of the finishing by milling will provide a gain on the next operations, save tools, and mainly because of the possibility of eliminating one step, consider a mould being machined in hardened state. The main objective of the present work is to study the finishing milling on flat surfaces using ball nose end mills and shows that the theoretical scallop height values yielded by CAM softwares is not reached on practical operations. Also, the factors governing flat surfaces as well as the best parameters for the WNr. 1.2367 tool steel showing that the studied milling parameters has a strong influence in the roughness, manly the cut sense. The knowledge of the best milling parameters and their influences on the final result, as well as others some factors, intend to offer information for industries and their programmers to optimize the die and moulds cutting plan and manufacturing.

Page generated in 0.0465 seconds