11 |
[en] DEVELOPMENT OF ANALYTICAL METHODS BASED ON LUMINESCENCE AND ELECTROPHORESIS FOR THE DETERMINATION OF ALKALOIDS (BETA-CARBOLINES, CAMPTOTHECIN AND DERIVATIVES) OF PHARMACOLOGICAL INTEREST / [pt] DESENVOLVIMENTO DE MÉTODOS ANALÍTICOS ESPECTROLUMINESCENTES E ELETROFORÉTICOS PARA A DETERMINAÇÃO DE ALCALOIDES (BETA-CARBOLINAS, CAMPTOTECINA E DERIVADOS) DE INTERESSE FARMACOLÓGICOFLAVIA FERREIRA DE CARVALHO MARQUES 14 October 2009 (has links)
[pt] Métodos analíticos foram desenvolvidos para a determinação seletiva de
alcalóides de interesse farmacológico. Com o objetivo de permitir a determinação
seletiva de camptotecina (CPT) em formulações farmacêuticas de irinotecana
(CPT-11) ou de topotecana (TPT), dois métodos espectrofluorimétricos e um
eletroforético, com detecção por fotometria de absorção, foram propostos. Os
métodos espectrofluorimétricos permitiram a determinação seletiva de CPT
usando um ajuste de alcalinidade do meio associado ao uso de varredura
sincronizada ou de derivada de 2ª ordem. Alternativamente, o procedimento de
derivação fotoquímica (com otimização com planejamento composto central)
eliminou completamente as interferências no sinal do CPT. Nas condições
otimizadas, a espectrofluorimetria permitiu a determinação de CPT em misturas
contendo até 50 vezes mais TPT ou contendo até 10 vezes mais CPT-11. A
resposta analítica indicou faixas lineares de trabalho e homoscedasticidade. O
limite de detecção (LD) foi da ordem de 10(-10) mol L(-1) para o método baseado na
derivação fotoquímica e uma ordem de grandeza a menos para os métodos sem
derivatização fotoquímica. Testes foram feitos em medicamentos a base de TPT
e de CPT-11 e as recuperações ficaram em torno de 100%. Esses resultados
foram comparáveis aos obtidos com método de referência (HPLC). O estudo de
incerteza de medição por fluorimetria indicou que a maior contribuição do
processo era a preparação de solução por avolumação. A contribuição dessa
fonte foi minimizada pela preparação de solução por meio de ajuste de massa,
causando um grande impacto na redução da incerteza expandida. O método
baseado na eletroforese eletrocinética capilar micelar (MEKC) permitiu a
quantificação simultânea de TPT, CPT e CPT-11. Para conseguir o ajuste final
das melhores condições, foi feito um estudo univariado seguido de um
planejamento composto central. Para se melhorar a sensibilidade da detecção
em até 76 vezes, foi utilizado um processo de pré-concentração no capilar por
modo de empilhamento e uma cela de caminho óptico alongado. A escolha do
tampão borato (pH 8,5) contendo SDS e acetonitrila permitiu condições robustas 7
de sinal de tempo de migração. A resposta analítica mostrou faixa linear e
homoscedatidade, além de repetitividade em torno de 3,5%. O LD foi da ordem
de 10(-7) mol L(-1) (TPT) e 10(-8) mol L(-1) (CPT-11 e CPT). Testes de recuperação em
amostras de saliva fortificadas foram feitos e comparados com os obtidos por um
método de referência (HPLC) de forma a mostrar a exatidão adequada para o
método proposto. Para a determinação seletiva de B-carbolinas, a fosforimetria
em substrato sólido (SSRTP) foi utilizada. O ajuste do átomo pesado seletivo e a
aplicação de técnica de varredura sincronizada e de 2ª derivada aumentaram o
grau de seletividade, pois induziu fosforescência dos analitos de interesse na
amostra e melhorou a resolução espectral em relação aos interferentes. O ajuste
da quantidade de HgCl2 (0,81 mg) permitiu a determinação seletiva de harmol na
presença de quantidades até 10 vezes maiores de harmine, harmane,
norharmane e harmaline. O método SSRTP seletivo proposto para determinação
de harmol foi comparado com o resultado obtido por um método de referência
adaptado baseado em MEKC, o qual também mostrou sua capacidade para a
determinação seletiva de harmol na presença dos interferentes. LD absoluto na
ordem de ng e comportamento linear da resposta analítica foram obtidos. No
caso do método analítico desenvolvido para a determinação de harmane na
presença de harmine em chás, estudos de otimização mostraram o AgNO3 como
sal de átomo pesado no substrato, solução de amostra em pH 11 e medições
feitas em 322 nm do espectro de 2ª derivada da varredura sincronizada
((delta)(lambda) = 109 nm). Testes de interferência mostraram que a matriz do chá não tem
influência no sinal do harmane e que nas / [en] Analytical methods were developed for the selective determination of
alkaloids of pharmacological interest. Aiming the selective determination of
camptothecin (CPT) in irinotecan (CPT-11) or topotecan (TPT) based
pharmaceutical formulations, two spectrofluorimetric methods and one
electrophoretic method with absorciometic detection were proposed. The
spectrofluorimetric method allowed the determination of CPT using the
adjustment of the alkalinity of the sample solution associated with the use of
synchronous scanning or 2nd order spectral derivation. Alternativelly, the
photochemical derivatization (optimized by central composite design) completely
eliminated interferences on the CPT signal. The optimized conditions allowed the
spectrofluorimetric determination of CPT in mixtures containing up to 50 times
more TPT or up to 10 times more CPT-11. The analytical response presented
linear working ranges and homocedasticity. The limit of detection (LD) was in the
order of 10(-10) mol L(-1) for the method based on photochemical derivatization and
one order of magnitude higher for the methods without photochemical
derivatization. Tests were made using TPT and CPT-11 based comercial drugs
and recoveries were around 100%. Such results were comparable to those
obtained with the reference method (HPLC). A study of fluorimetric measurement
uncertainty indicated that the greatest contribution in the process was the
preparation of solution by volume. The contribution from this source was
minimized by the preparation of solutions by weight measurement which caused
a major impact in reducing the expanded uncertainty. The method based on
micellar electrokinetic capillary electrophoresis (MEKC) allowed the simultaneous
quantification of TPT, CPT and CPT-11. To achieve final adjustment of
conditions, an univariated study was made followed by a central composite
design. To improve the sensitivity of detection up to 76 times, a pre-concentration
in the capillary by the normal stacking mode was used along with an extended
optical path cell. The choice of borate buffer (pH 8.5) containing SDS and
acetonitrile implicated in robust conditions of signal and migration times. The
response showed analytical linear working range and homocedasticity, and
9 repeatability of around 3.5%. The LD was in the order of 10(-7) mol L(-1) (TPT) and
10(-8) mol L(-1) (CPT-11 and CPT). Recovery tests using spiked saliva samples were
made and compared with those obtained by a reference method (HPLC) to show
the appropriated accuracy for the proposed method. For the selective
determination of B-carbolines, solid surface room temperature phosphorimetry
(SSRTP) was used. The adjustment of the selective heavy atom and the
application of synchronized scanning technique and 2nd order spectral derivation,
increased the degree of selectivity, because induced phosphorescence of the
analytes of interest in the sample and improved spectral resolution. The
adjustment of the amount of HgCl2 (0.81 mg) allowed the selective determination
of harmol in the presence of up to 10 times higher amounts of harmine, harman,
harmaline and norharman. The method proposed for selective SSRTP
determination of harmol was compared with the results obtained by an adapted
method based on MEKC, which also showed its ability to determine harmol in the
presence of interferences. The absolute limit of detection in the ng order and
linear behavior of the analytical response was obtained. For the analytical
method developed for the determination of harman in the presence of harmine in
teas, optimization studies indicated the following conditions: AgNO3 as the heavy
atom salt deposited on the substrate, sample solution at pH 11 and
measurements made at 322 nm of the 2nd order derivated synchronous scanning
spectrum ((delta)(lambda) = 109 nm). Tests showed that, in optimized conditions, the tea
matrix had no influence on the harman signal and and that harman could be
determined in samples containing harmine in concentrations up to two times
higher. The
|
12 |
[en] STANDARDIZATION AND METROLOGICAL RELIABILITY OF CIGARETTE FIRMNESS RESULTS / [pt] PADRONIZAÇÃO E CONFIABILIDADE METROLÓGICA DOS RESULTADOS DE FIRMEZA DO CIGARROFRANCY GOERSCH NOGUEIRA 24 March 2006 (has links)
[pt] A qualidade de um cigarro pode ser avaliada por
parâmetros
físicoquímicos.
A caracterização de muitos destes parâmetros é essencial
para a
definição dos índices utilizados por um fabricante de
cigarros para
acompanhamento do produto no mercado. A firmeza do
cigarro
é um dos
parâmetros utilizados para definição desses índices, e
avalia seu grau de rigidez,
podendo ser definido, de uma maneira geral, como a
relação
entre o diâmetro
final do cigarro, após a realização de um ensaio de
compressão, e o diâmetro
inicial. A Firmeza é função de três variáveis:
deformação
vertical do cigarro,
produzida pela aplicação de uma força padronizada, valor
especificado de
umidade no fumo e circunferência média do cigarro. Com o
objetivo de
possibilitar a comparação entre os diversos produtos, a
firmeza medida é
corrigida para um valor de referência de umidade,
previamente especificado,
pela utilização de um modelo exponencial. Apesar deste
modelo ter sido
devidamente validado para os produtos Souza Cruz, e ter
sido considerado
aceitável para determinação da firmeza corrigida, não
foram avaliadas as
incertezas associadas à sua utilização. Neste trabalho,
foram utilizados nos
ensaios onze (11) tipos de cigarros e medida a firmeza
conforme os
procedimentos adotados pela empresa, previamente
qualificados. O método dos
mínimos quadrados foi utilizado para o desenvolvimento
de
modelos, juntamente
com a estimativa das incertezas. Neste estudo foram
avaliados também outros
modelos, no sentido de se obter aquele que gerasse
resultados com menores
incertezas, bem como a avaliação dos parâmetros que
contribuem para o
aumento da incerteza de medição da firmeza corrigida.
Foi
concluído que as
características do produto contribuem para a elevada
incerteza associada, o que
resulta em repetitividade não muito boa. Com base nestes
resultados, sugere-se
o estabelecimento de critérios de aceitação do produto,
compatíveis com as
incertezas associadas à medição, comparando-se com os
valores de Firmeza
normalmente aceitos e testados pelo mercado. / [en] Cigarette quality can be evaluated by physical and
chemical parameters.
Characterizing most of these parameters is essential to
defining the indices
cigarette manufacturers use while monitoring the product
on the market.
Cigarette firmness is one of the parameters used for
defining these indices and
evaluates cigarette degree of rigidity. Generally, it can
be defined as the ratio of
the final cigarette diameter, following a compression
assay, to its initial diameter.
Firmness is a function of three variables: cigarette
upright deformation as
produced by applying a standard load; specified tobacco
moisture, and cigarette
mean circumference. With a view to enabling comparison
between several
products, the measured firmness is corrected to a
previously specified reference
moisture value by having use of an exponential model. In
spite of this model
having been properly validated for Souza Cruz products and
considered as
acceptable for the determination of corrected firmness,
the uncertainties
associated with its use have not been evaluated. The
trials described in this
paper used eleven (11) types of cigarettes and the
firmness was measured as
per previously qualified procedures used by Souza Cruz.
The method of
minimum squares was used in the development of models
jointly with uncertainty
estimate. Also evaluated in this study were other models
so as to achieve that
which could generate results with lowest uncertainties and
those parameters
which contribute to increasing uncertainty of corrected
firmness measurements.
The conclusion was that product characteristics contribute
to increasing the
associated uncertainty which results in poor
repeatability. On the basis of these
results, it is suggested that product acceptance criteria
be established that are
compatible with measurement associated uncertainties by
comparing these with
firmness values usually accepted and tested by the market.
|
13 |
[en] STUDY OF THE METROLOGICAL RELIABILITY OF SPHYGMOMANOMETERS / [pt] ESTUDO DA CONFIABILIDADE METROLÓGICA DE ESFIGMOMANÔMETROSSERGIO HENRIQUE SILVA JUNIOR 08 October 2008 (has links)
[pt] Observa-se um crescente interesse na determinação da
incerteza de medição para a avaliação de conformidade e
garantia da qualidade, principalmente nos setores de meio-
ambiente, segurança, saúde e indústria, nos quais o
resultado da medição é considerado crítico por lidar
diretamente com seres humanos. Na medição da pressão
arterial, conforme estudos realizados em países como a
Austrália, Inglaterra, Turquia e Brasil, observa-se uma
grande preocupação com a confiabilidade dos resultados
obtidos por esfigmomanômetros mecânicos não invasivos.
Nestes estudos, erros de até 4,4 kPa (33 mmHg) foram
encontrados nos instrumentos avaliados, contra o valor de
erro máximo de 0,53 kPa (4 mmHg) definido
na OIML R 16-1:2002. Atualmente, a avaliação da
confiabilidade dos esfigmomanômetros
mecânicos é obtida considerando apenas o erro de medição,
sem considerar a incerteza de medição. Com a motivação de
contribuir para a garantia da confiabilidade metrológica
dos esfigmomanômetros mecânicos não invasivos,
usados mundialmente em hospitais e residências, o presente
trabalho tem por objetivo associar a incerteza de medição
na avaliação da confiabilidade metrológica
destes instrumentos. Para a realização das medições foi
montado um aparato envolvendo instrumentos de monitoração
ambiental conforme recomendações internacionais
(OIML R-16-1:2002) e nacionais (ABNT NBR-14105:1998 e
NIEDIMEL- 006). Os dados do presente trabalho foram obtidos
por meio de medições diretas em esfigmomanômetros novos e
usados utilizando um padrão de pressão. Foram avaliados: o
erro de medição, a histerese, o erro fiducial e a incerteza
de medição. Os resultados obtidos com o presente trabalho
mostram que, em função da incerteza de medição, o erro
máximo permissível de 0,53 kPa (4 mmHg) pode
não fornecer a confiabilidade adequada. Se for considerado
apenas o erro de medição do manômetro conforme a OIML R 16-
1:2002, 60 % dos esfigmomanômetros avaliados foram
aprovados. Se for considerado o erro e a incerteza de
medição do manômetro, conforme proposto, apenas 12 % dos
esfigmomanômetros foram aprovados. Com base nos resultados
obtidos no presente trabalho, propõe-se reduzir o erro
máximo admissível para estes instrumentos, incorporando a
incerteza de medição, sem a necessidade de realizar na
prática o seu cálculo. Com base nos resultados do presente
trabalho recomenda-se uma revisão na faixa de
erro máximo permissível na avaliação da OIML, em conjunto
com a proposta de uma nova especificação do manômetro usado
nos esfigmomanômetros, com redução do erro intrínseco e
melhora de sua resolução. / [en] It is observed an increasing interest on the estimation of
measurement uncertainty
to deciding on conformity and quality assurance, mainly in
the fields of
environment, safety, health and industry, in which the
measurement results are
critical once they directly deal with human beings.
According to studies performed
in Australia, England, Turkey and Brazil, a great concern
is observed with
the reliability of the results obtained for blood pressure
measurements by noninvasive
mechanical sphygmomanometers. In these studies, errors of
up to 4,4 kPa
(33 mmHg) were obtained in the evaluated instruments,
against the value of maximum
error of 0,53 kPa (4 mmHg) required by OIML R 16-1:2002.
Nowadays,
the evaluation of the reliability of these measurement
instruments for medical diagnosis
is obtained considering only the measurement error
(according to OIML R
16-1:2002), without taking into account the measurement
uncertainty. Motivated
to contribute for the metrological reliability of non-
invasive mechanical sphygmomanometers,
globally used in hospitals and residences, the present work
aims
at developing a model to associate the measurement
uncertainty on the metrological
reliability evaluation of these instruments. In order to
perform the measurements
with the sphygmomanometers, a set-up were prepared with
environmental
monitoring according to international recommendation (OIML
R-16:2002) and
national standards (ABNT NBR-14105:1998 and NIE-DMEL-006).
The data of
the present work were obtained by means of direct
measurements in new and in
use sphygmomanometers, utilizing a pressure pattern.
Calculation of the following
parameters was performed: measurement error, hysteresis,
fiducial error and
measurement uncertainty. The obtained results show that, as
a function of the
measurement uncertainty, the maximum permissible error of
0.53 kPa (4 mmHg)
can be overcome. Considering the manometer measurement
error, according to OIML R 16-1:2002, 60 % of the non-
invasive mechanical sphygmomanometers
evaluated were approved. When considering not only the
measurement error, but
also measurement uncertainty of the manometer, only 12% of
the non-invasive
mechanical sphygmomanometers were approved. Based on the
present results, a
reduction of the maximum permissible error for these
instruments, incorporating
the measurement uncertainty, without the need to calculate
it in the verification
procedure, is proposed. This work recommends not only a
review of OIML maximum
permissible error for sphygmomanometers, but also proposes
a new configuration
of the instrument, with reduction of intrinsic error and
improvement of
resolution.
|
14 |
[en] IMPROVEMENT OF THE METROLOGICAL RELIABILITY IN THE INSPECTION OF MACHINED COMPONENTS WITH APPLICATIONS IN THE NUCLEAR INDUSTRY / [pt] MELHORIA DA CONFIABILIDADE METROLÓGICA NA INSPEÇÃO DE COMPONENTES USINADOS COM APLICAÇÃO NA INDÚSTRIA NUCLEARVICTOR BARBOSA MARTIN 04 January 2011 (has links)
[pt] A presente pesquisa de mestrado contribui para a melhoria da confiabilidade metrológica de componentes usinados, utilizados na indústria nuclear para produção de energia elétrica, produzidos com reduzidas tolerâncias definidas em projeto. O trabalho é de interesse da empresa Indústrias Nucleares do Brasil (INB), que atua na cadeia produtiva do urânio e produz o elemento combustível para as usinas nucleares de Angra, pois aprimora a analise do processo de medir. Cumprindo o objetivo da dissertação e fazendo uso da técnica de medição por coordenadas, foi desenvolvida uma metodologia para avaliação do processo de inspeção dimensional de componentes usinados da indústria nuclear. A motivação é a melhoria da confiabilidade metrológica requerida na inspeção, agregando conhecimento e inovação tecnológica. O trabalho incorpora uma análise das incertezas associadas ao processo de medição por coordenadas de componentes usinados. A metodologia utiliza a pesquisa bibliográfica e a experimental e, à luz dos métodos de avaliação de incertezas baseados numa formulação estatística, avalia processos de medição de interesse da indústria nuclear. Dentre os resultados são caracterizadas as influências na medição da característica objeto da medição; é avaliada a divergência da medição em relação a um padrão e desenvolvida uma ferramenta para a avaliação e melhoria do processo de medição. Como conclusão, o trabalho contribui com o aprimoramento da técnica de medição por coordenadas incorporando inovações tecnológicas na melhoria da qualidade dos processos de inspeção dimensional. / [en] This Master’s Thesis contributes to the improvement of metrological reliability of machined components that are used in the nuclear industry for the production of electrical energy and which are produced with reduced tolerances defined in the project. The work is of interest to the company Indústrias Nucleares do Brasil (INB), which operates in production of the uranium fuel assemblies for nuclear power plants in Angra, improving the analysis of the measuring process. The dissertation fulfill the goal, by the development of a methodology to use in evaluation of coordinate measuring technique that is used in the process of dimensional inspection of machined components for the nuclear industry. The motivation is to improve the metrological reliability required in the inspection, adding knowledge and technological innovation. The work incorporates an analysis of uncertainties associated with the measurement process by coordinates, of machined components. The methodology uses bibliographic research and experimental methods of evaluation of uncertainty based on a statistical formulation, in measurement procedures of interest to the nuclear industry. In the results are characterized the influences of the measurement on the object characteristic of measurement, the divergence is evaluated by measuring against a standard. It was developed a tool to evaluate and improve the measurement process. In conclusion, the study contributes to the improvement of the coordinate measuring technique incorporating technological innovations, improving the quality of procedures for dimensional inspection.
|
15 |
[en] INTERFEROMETRIC PRIMARY SYSTEM FOR LENGTH MEASUREMENTS AND APPLICATIONS IN NANOMETROLOGY / [pt] SISTEMA INTERFEROMÉTRICO PRIMÁRIO PARA MEDIDAS DE COMPRIMENTO E APLICAÇÕES EM NANOMETROLOGIA02 January 2015 (has links)
[pt] Neste trabalho são apresentados os resultados referentes ao desenvolvimento de um sistema interferométrico primário, o interferômetro Linnik, para medidas de comprimento de amostras na escala micrométrica e nanométrica. O sistema experimental foi caracterizado e otimizado para prover rastreabilidade a degraus de altura, usados como referência na escala de comprimento. As principais fontes de incerteza foram avaliadas, sendo a planicidade do artefato o parâmetro com o maior valor de contribuição para a incerteza final. A estabilidade do sistema de referência pode ser mostrada através da alta reprodutibilidade apresentada ao longo de algumas semanas de medição. Este também serviu como base para prover a rastreabilidade no SI, para instrumentos ópticos tais como OCT, AFM e microscópios confocais, sendo os dois últimos usados na área de nanotecnologia. Estes instrumentos foram calibrados usando como padrão de transferência os degraus de altura, previamente avaliados no interferômetro Linnik. Com isto, foi estabelecida a rastreabilidade na escala de comprimento para alguns institutos no país. / [en] In this work are presented the results related to the development of a primary interferometric system, the Linnik interferometer for length measurements of samples in the micrometer and nanometer scales. The experimental system has been characterized and optimized to provide traceability to step height, used as the reference standards in length scale. The main sources of uncertainty were evaluated, and the flatness of the artifact was the parameter with the highest contribution to the final uncertainty. The stability of the reference system can be demonstrated through the reproducibility that was evaluated over several weeks. This system also served as the basis to provide traceability to the SI for optical instruments such as OCT and confocal microscopes AFM, the latter two being used in the field of nanotechnology. These instruments were calibrated using step heights, as transfer standards, that were previously evaluated in Linnik interferometer. Therefore, it was established the traceability in length scale for some institutes in the country.
|
16 |
[en] AN APPROACH TO VALUE FLEXIBILITY CONSIDERING UNCERTAINTY AND FUTURE INFORMATION: AN APPLICATION TO SMART WELLS / [pt] UMA ABORDAGEM PARA AVALIAÇÃO DE FLEXIBILIDADE CONSIDERANDO INCERTEZA E INFORMAÇÃO FUTURA: UMA APLICAÇÃO PARA POÇOS INTELIGENTESANA CAROLINA ALVES ABREU 06 December 2016 (has links)
[pt] Os poços inteligentes permitem a criação de uma estratégia de desenvolvimento flexíveis, dada, entre outras coisas, sua capacidade de adquirir informações relevantes necessárias para tomadas de decisão futuras. No entanto, se não considerarmos as incertezas quando pretendemos calcular o valor dessa flexibilidade, a estratégia de otimização resultante terá dois problemas fundamentais: pode-se atribuir um valor muito elevado para os poços inteligentes, e não se tira proveito da capacidade de adaptar e mitigar incertezas. Este trabalho propõe uma abordagem para avaliar flexibilidade sob incerteza, buscando a estratégia de controle de fluxo que maximize o valor presente líquido esperado, reagindo dinamicamente a novas informações. Demonstramos a abordagem proposta utilizando toy problems, nos quais podemos avaliar as soluções de otimização em uma ampla gama de cenários, incluindo incertezas e flexibilidade, com um reduzido tempo de avaliação. Em seguida, aplicamos esta abordagem em um modelo de reservatório que destaca aspectos como: otimização de ativos sob incerteza, controle flexível baseado em informações futuras, e quantificação do valor da flexibilidade e medições futuras. Além disso, contribuindo para seleção apropriadas da tecnologia de poços inteligentes e de medições, a abordagem proposta oferece uma árvore de decisão que descreve a estratégia flexível ideal, com os controles da válvula que adequadamente consideram medições futuras e seus impactos na redução de incertezas. Esta abordagem provê uma avaliação qualitativa, indicando se o campo tem potencial de melhoria significativa utilizando poços inteligentes, e avaliação quantitativa dos benefícios da tecnologia, resultando em uma estratégia realizável, que orienta o ajuste das válvulas um campo real. / [en] Smart well technology has the ability to acquire relevant information required for future decision-making, enabling the generation of a development strategy with future flexibility. However, to value its flexibility, if we do not account for uncertainty when performing an optimization, the resulting strategy will have two key shortcomings: it will assign too high value to the smart wells, and it will not take advantage of the ability of the smart wells to adapt and mitigate to uncertainty. We propose a strategy that allows to value flexibility under uncertainty, seeking the flow control strategy that maximizes the expected net present value, dynamically reacting to new information as it is acquired. We demonstrate the proposed approach using toy problems for which we can evaluate optimization solutions for a broad range of scenarios, including uncertainty and flexibility to accommodate future measurements, with a reduced time of evaluation. We then apply this proposed approach on a reservoir model that highlights its novel aspects: asset optimization under uncertainty, flexible control based on future information, and quantification of the value of flexibility and future measurements. In addition to valuing flexibility and future information, which contributes to the selection of appropriate smart-well technology and measurements, the proposed approach delivers a decision tree that describes a flexible strategy of optimum valve settings that properly accounts for future measurements and their impact on uncertainty reduction. This approach gives a qualitative value, indicating whether the field has the potential of significant improvement using smart wells, and a quantitative valuation of the benefits of smart completions resulting in a realizable strategy to guide the control of these completions in a real field management project.
|
17 |
[pt] APOIOS COMPRADOS: FORMAS CONTEMPORÂNEAS DE SUPORTE À MATERNAGEM / [en] PURCHASED SUPPORT: CONTEMPORARY ASSISTANCE FOR MOTHERHOODROBERTA CORRÊA LANZETTA 06 September 2016 (has links)
[pt] O Objetivo desse trabalho é analisar, através de um estudo teórico e de uma pesquisa de campo, os possíveis atravessamentos da cultura contemporânea, com ênfase nas questões da eficiência e do consumo, na construção das primeiras relações mãe-bebê e suas repercussões nas práticas de maternagem. Buscou-se para isso apoio na Psicanálise, na História e na Sociologia. Diversos aspectos estão envolvidos nas expectativas atuais diante da maternidade relacionados com sentimentos de insegurança e incerteza presentes no mundo em que vivemos, onde a vida é marcada pela incerteza, instabilidade e fluidez dos valores. O sujeito contemporâneo por conta disso acredita precisar de especialistas para respaldá-lo nos mais diversos aspectos. As inseguranças presentes na situação da maternidade, em especial no caso do primeiro filho, são aqui colocadas em relevo, problematizando a busca de apoios disponibilizados por um mercado que hoje propõe respostas em forma de cursos, manuais e diversos outros produtos a serem consumidos. / [en] This work aims to analyze, through a theoretical study and field research, the possible influences of contemporary culture, with an emphases on issues of efficiency and consumption, in the process of building the relationship between mother and baby and their repercussions of maternal practices. For that, a support on Psychoanalysis, History and Sociology was explored. A variety of aspects are involved in nowadays expectations on maternity. Feelings of insecurity and uncertainty are present in the contemporary world, where life is dictated by uncertainty, instability and fluidity of values. Due to that, contemporary subjects often believe they need specialists to back them up in many different areas. The insecurities present in maternity, especially when it comes to firstborns, are here highlighted, questioning the search of support made available by a market that today proposes answers in form of courses, textbooks and many other products to be consumed.
|
18 |
[en] ON INTERVAL TYPE-2 FUZZY LOGIC SYSTEM USING THE UPPER AND LOWER METHOD FOR SUPERVISED CLASSIFICATION PROBLEMS / [pt] SISTEMAS DE INFERÊNCIA FUZZY INTERVALAR DO TIPO-2 USANDO O MÉTODO SUPERIOR E INFERIOR PARA PROBLEMAS DE CLASSIFICAÇÃO SUPERVISIONADOSRENAN PIAZZAROLI FINOTTI AMARAL 04 October 2021 (has links)
[pt] Os sistemas de inferência fuzzy são técnicas de aprendizado de máquina
que possuem a capacidade de modelar incertezas matematicamente. Eles são
divididos em sistemas de inferências fuzzy tipo-1 e fuzzy tipo-2. O sistema de
inferência fuzzy tipo-1 vem sendo amplamente aplicado na solução de diversos
problemas referentes ao aprendizado de máquina, tais como, controle, classificação,
clusterização, previsão, dentre outros. No entanto, por apresentar uma
melhor modelagem matemática das incertezas, o sistema de inferência fuzzy
tipo-2 vem ganhando destaque ao longo dos anos. Esta melhora modelagem
vem também acompanhada de um aumento do esforço matemático e computacional.
Visando reduzir tais pontos para solucionar problemas de classificação,
este trabalho apresenta o desenvolvimento e a comparação de duas funções de
pertinência Gaussiana para um sistema de inferência fuzzy tipo-2 intervalar
usando o método superior e inferior. São utilizadas as funções de pertinência
Gaussiana com incerteza na média e com incerteza no desvio padrão. Ambos os
modelos fuzzy abordados neste trabalho são treinados por algoritmos baseados
em informações de primeira ordem. Além disso, este trabalho propõe a extensão
dos modelos fuzzy tipo-2 intervalar para apresentarem múltiplas saídas,
reduzindo significativamente o custo computacional na solução de problemas
de classificação multiclasse. Finalmente, visando contextualizar a utilização
desses modelos em aplicações de engenharia mecânica, este trabalho apresenta
a solução de um problema de detecção de falhas em turbinas a gás, utilizadas
em aeronaves. / [en] Fuzzy logic systems are machine learning techniques that can model
mathematically uncertainties. They are divided into type-1 fuzzy, and type-2
fuzzy logic systems. The type-1 fuzzy logic system has been widely applied to
solve several problems related to machine learning, such as control, classification,
clustering, prediction, among others. However, as it presents a better
mathematical modeling of uncertainties, the type-2 fuzzy logic system has
received much attention over the years. This modeling improvement is also
accompanied by an increase in mathematical and computational effort. Aiming
to reduce these issues to solve classification problems, this work presents
the development and comparison of two Gaussian membership functions for a
type-2 interval fuzzy logic system using the upper and lower method. Gaussian
membership functions with uncertainty in the mean and with uncertainty
in the standard deviation are used. Both fuzzy models covered in this work
are trained by algorithms based on first order information. Furthermore, this
work proposes the extension of interval type-2 fuzzy models to present multiple
outputs, significantly reducing the computational cost in solving multiclass
classification problems. Finally, aiming to contextualize the use of these models
in mechanical engineering applications, this work presents the solution of
a problem of fault detection in aircraft gas turbines.
|
19 |
[en] METHODOLOGY FOR DETERMINING THE POTENTIAL MARKET OF A MICROTURBINE BASED COGENERATION SYSTEM FOR ELECTRIC ENERGY AND HOT WATER PRODUCTION / [pt] METODOLOGIA PARA DETERMINAÇÃO DO MERCADO POTENCIAL DE UM SISTEMA DE COGERAÇÃO COM MICROTURBINA PARA PRODUÇÃO DE ENERGIA ELÉTRICA E ÁGUA QUENTEJOAO VIEIRA DE ARAUJO 11 October 2007 (has links)
[pt] O uso seqüencial de energia elétrica e energia térmica a
partir da energia química
do mesmo combustível tem sido estudado para melhorar o
custo benefício de uma
geração distribuída. O objetivo deste estudo é determinar
o mercado potencial desta
tecnologia na região de influência da concessionária local
de energia elétrica. Para
alcançar este objetivo, foi necessário avaliar o
desempenho de um sistema de cogeração
com uma microturbina fornecendo potência elétrica e
energia térmica através dos gases
de exaustão que aquecem água para o ginásio esportivo da
PUC-Rio. O sistema está
configurado por uma microturbina, uma caldeira de
recuperação, um reservatório térmico
(boiler) e uma caixa para alimentação de água fria.
Resultados obtidos de testes de curta
duração, através de uma metodologia desenvolvida, para a
avaliação do desempenho do
sistema de cogeração na produção de energia elétrica e
térmica, são apresentados. Os
testes foram realizados para potências elétricas de 100,
75, 50 e 25 % da carga máxima da
microturbina. Em adição, testes para avaliação do
desempenho ao longo do tempo em
função das variações da carga e das condições ambientais
foram estudados. Além disso,
através de uma metodologia desenvolvida, mostram-se os
resultados nos cálculos de
incerteza dos parâmetros analisados. Dados de consumo de
energia elétrica em janeiro de
2003, de cerca de 8000 consumidores na área de concessão
da LIGHT SESA, em
diferentes classes tarifárias, atualizadas para 2007,
foram utilizados com a metodologia
desenvolvida para estimar o mercado potencial de energia
elétrica na região de influência
da concessionária local de energia elétrica em 384,5 MW e
20415 MWh/mês,
considerando uma taxa interna de retorno mínimo de 15%
a.a. Foi mostrado que o
elevado custo da microturbina é uma barreira para sua
introdução no mercado. Entretanto,
a cogeração pode colaborar substancialmente para melhorar
o custo benefício. Estas
conclusões foram obtidas a partir do tempo de retorno do
investimento no sistema pelos
consumidores analisados. / [en] The sequential use of electric energy and thermal energy
from the chemical energy
of the same fuel has been studied to improve the cost
benefit of a distributed generation.
The objective of this study is to evaluate the potential
market of this technology in the
region of influence of the local utility of electric
energy.utility company (LIGHT). In
order to attain this objective, it was necessary to
evaluate the performance of a micro
turbine based cogeneration system used for supplying
electrical and thermal energy to
PUC-RIO´S Gymnasium. The system consists of a
microturbine, a heat recovery boiler,
and a cold water feeding reservoir. The short duration
test results are presented for the
evaluation of the cogeneration system performance for the
production of electric and
thermal energy. The tests were carried on for 100, 75, 50
and 25% micro turbine electric
energy generation loads. Time performance of the micro
turbine was also studied.
Moreover, a methodology was shown to calculate the
uncertainty of measurements of
several performance parameters. The micoturbine marked
potential was estimated by
analyzing the consumption of about 8000 clients in January
2003, updating the tariffs to
2007, resulting in 384,5 MW and 20415 MWh/month,
considering a minimum internal
rate of return of investiment of 15% per year, during a 15
year period. It was concluded
that the microturbine cost is still a barrier to its
market penetration. Cogeneration can be
used to improve the cost benefit of the system.
|
20 |
[en] CONTRIBUTIONS FOR THE STRENGTHENING OF THE BRAZILIAN NATIONAL LABORATORY OF TIME AND FREQUENCY / [pt] CONTRIBUIÇÕES PARA O FORTALECIMENTO DO LABORATÓRIO NACIONAL BRASILEIRO DE METROLOGIA DE TEMPO E FREQÜÊNCIAJOSE LUIZ MACHADO KRONENBERG 13 December 2007 (has links)
[pt] Objetivos: três são os objetivos centrais da presente
pesquisa de mestrado em
metrologia: (i) no âmbito da missão institucional da
Divisão Serviço da Hora (DSHO)
do Observatório Nacional (ON), desenvolver um diagnóstico
da melhor capacidade de
medição e do sistema da qualidade do Laboratório Primário
de Tempo e Freqüência
(LPTF); (ii) à luz das práticas internacionais, calcular e
expressar as incertezas de
medição associadas à realização e disseminação das
unidades de tempo e freqüência em
âmbito nacional; (iii) em atendimento às exigências do
Acordo de Reconhecimento
Mútuo celebrado pelo Brasil no âmbito da Convenção do
Metro, preparar e
disponibilizar a declaração da melhor capacidade de
medição (CMC) do LPTF, na base
de dados do Bureau International des Poids et Mesures
(BIPM).
Motivação: a presente pesquisa de mestrado foi motivada
pela necessidade de
se: (i) formalizar a melhor capacidade de medição na base
internacional de dados Key
Comparison Data Base (KCDB) do Bureau International des
Poids et Mesures (BIPM);
(ii) adequar a nova estrutura do DSHO/ON às instalações da
recém-construída infraestrutura
laboratorial; (iii) estabelecer a rastreabilidade nacional
em TF para atender à
nova formulação introduzida pelo BIPM (método AV); (iv)
implementar o Plano de
Ações para melhoria do Sistema da Qualidade da DSHO, pré-
condição ao
reconhecimento nacional e internacional da metrologia
brasileira em TF.
Contextualização: em Metrologia, as comparações
interlaboratoriais
constituem-se em prática e exigências para se garantir
padronização e a confiança mútua
nos processos de desenvolvimento e aprimoramento de
métodos e processos de
medição. A medição e difusão da grandeza tempo (data-hora)
necessitam rastreabilidade
permanente e contínua ao padrão mundial, impondo aos
laboratórios que participam da
cadeia de rastreabilidade uma responsabilidade e
dificuldade operacional para
manutenção ininterrupta deste serviço. A melhoria e
manutenção do Sistema da
Qualidade, a caracterização das incertezas de medição e a
divulgação desses dados junto aos foros internacionais por
meio do BIPM constituem responsabilidades da missão
institucional do Laboratório Primário de Tempo e
Freqüência.
Metodologia: o trabalho desenvolveu-se em conformidade aos
seguintes
preceitos metodológicos: (i) diagnóstico e caracterização
dos padrões (primários e
secundários), equipamentos e sistemas de medição
disponíveis; (ii) identificação das
variáveis críticas dos sistemas de medição, com vistas à
determinação das incertezas a
elas associadas, tendo como referência o Guide to the
Expression of Uncertainty in
Measurement (GUM) e a Variância de Allan (avaliação da
estabilidade de osciladores);
(iii) caracterização da estrutura da rastreabilidade
brasileira em tempo e freqüência e
definição do seu status junto ao BIPM (formalizado
mensalmente pela sua Circular-T);
(iv) caracterização da melhor capacidade de medição do
LPTF, para torná-la disponível
na base de dados KCDB do BIPM.
Resultados: à luz das práticas internacionais, os
seguintes resultados foram
consolidados: (i) expressão das incertezas de medição
associadas à realização e
disseminação das unidades de Tempo e Freqüência do LPTF do
Brasil; (ii) expressão e
padronização da melhor capacidade de medição em TF do LPTF
para inclusão na base
de dados internacional KCDB do BIPM; (iii) caracterização
e equacionamento de
questões críticas dos processos de calibração que afetam a
melhor capacidade de
medição e do Sistema da Qualidade da DSHO.
Conclusões: com base numa avaliação crítica do sistema
instalado, o presente
trabalho contribuiu para a consolidação de um sistema de
metrologia primária de TF
mais robusto no Brasil, viabilizando a implementação
operacional de novos padrões e
equipamentos, rotinas de monitorament / [en] Objectives: the three main objectives of the present
research project are as
follows: (i) to develop a diagnosis of the best
calibration and measuring capability and
the quality system of the Brazilian National Time and
Frequency Primary Laboratory (
LPTF ) of the Time Service Division ( DSHO ) of the
National Observatory (ON) ; (ii)
to calculate and express, in accordance with international
practices, the measuring
uncertainties associated with the achievement and
dissemination of the time and
frequency units within the country and (iii) to prepare
and make available the
declaration of the best calibration and measurement
capability (CMC) of the LPTF
according to the database of the Bureau International des
Poids et Measures (BIPM) as
required by the Mutual Recognition Agreement (signed by
Brazil within the scope of
the Convention of the Metre).
Motivation: several factors motivated this master´s degree
research project: (i)
the necessity of making available the best calibration and
measurement capability
according with the international Key Comparison Data Base
(KCDB ) of the Bureau
International de Poids et Measures (BIPM); (ii) the need
to adapt the new structure of
the Time Service Division (DSHO) of the National
Observatory (ON) to the recently
built laboratory infrastructure; (iii) the necessity of
establishing a national traceability of
TF according to the new format introduced by the BIPM (AV
method) and (iv) the
urgent need to implement the Action Plan to improve the
Quality System of the
DSHO, a pre-established condition to both, national and
international recognition.
Context: In metrology, interlaboratory comparisons are
common practice. This
is the recommended procedure to guarantee standardization
and mutual recognition in
the development and improvement of methods of measurement.
Measurement and
dissemination of time (date-hour), in particular, requires
continuous and permanent
traceability to international standards as they impose to
time and frequency laboratories
an uninterrupted provision of this service. The
improvement and surveillance of the
Quality System, the characterization of the measuring
uncertainties and dissemination of time and frequency data
to the relevant international fora to meet BIPM
requirements
constitute responsibilities of the institutional mission
of any Primary Time and
Frequency Laboratory.
Methodology: the present work was developed in accordance
with the
following methodological principles: (i) diagnosis and
characterization of the standards
(primary and secondary), equipment and measuring systems
available at the LPTF; (ii)
identification of the critical variables of the measuring
systems to determine the
uncertainties associated with the measuring of time and
frequency, having the Guide to
the Expression of Uncertainty in Measurement (GUM) and the
Allan Variance
(oscillators stability evaluation) as reference; (iii)
characterization of the Brazilian time
and frequency traceability structure and its formalization
in accordance with the
monthly formalized BIPM Circular-T; (iv) characterization
of the CMC of the LPTF to
make it available at the KCDB of the BIPM.
Results: according to international practices, the
following results were
consolidated: (i) expression of the measuring
uncertainties associated to the realization
and dissemination of time and frequency; (ii) expression
and standardization of the best
calibration and measuring capability in time and frequency
of the LPTF to be included
in the BIPM Key Comparison Data Base; (iii)
characterization and understanding of
critical issues inherent to calibration processes which
directly affect the best
measurement capability and the Quality System of the DSHO.
Conclusion: based on a critical evaluation of the
metrological system in place,
the present work has contributed to the consolidation of a
more robust primary system
of time and frequency in Brazil. Such system allows for
the
|
Page generated in 0.0464 seconds