• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 29
  • 16
  • 10
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 171
  • 39
  • 30
  • 27
  • 23
  • 23
  • 22
  • 18
  • 18
  • 18
  • 18
  • 18
  • 18
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Utilização do Lodo Gerado no Tratamento Por Eletrocoagulação de Chorume Como Fonte de Nutrientes no Crescimento Inicial de Milho (zea Mays L.)

BETIM, F. S. 28 March 2016 (has links)
Made available in DSpace on 2016-08-29T15:35:42Z (GMT). No. of bitstreams: 1 tese_9764_Fernando Silva Betim.pdf: 1495331 bytes, checksum: b41448f270e426dc58753a0014c5f3ab (MD5) Previous issue date: 2016-03-28 / Os resíduos sólidos urbanos (RSU) em grandes lixões são um dos maiores problemas urbanos atuais. Dentre os produtos gerados, há o chorume, um contaminante derivado de processos físicos, químicos e bioquímicos da decomposição do RSU, que, no geral, é composto de matéria orgânica dissolvida, compostos orgânicos xenobióticos, macrocomponentes inorgânicos e metais altamente tóxicos. Dentre os possíveis tratamentos, destaca-se a eletrocoagulação. Após este tratamento, resta-se um lodo, no qual há matéria orgânica e diversos nutrientes, altamente importantes para a agricultura. O presente trabalho avaliou a utilização do lodo gerado nesse tratamento como fonte de nutrientes no crescimento inicial de milho. Dose equivalentes a 0, 5, 10, 20, 30 e 40 t ha-1 foram aplicadas em um latossolo e, após 30 dias, o milho foi semeado, sendo colhido após 30 dias. Utilizando-se as técnicas de ICP-OES e FAAS, foi verificado o aumento da disponibilidade de Na, K, Ca, Mg, Mn, Fe, Cu e Zn, no solo, e redução da fração tóxica do Al no mesmo. Já nas folhas de milho, observou-se aumento nos teores de Na, K, Mn e Fe, e redução do Ca e Mg. Não foram observados aumentos significativos na massa seca e altura das plantas. Também verificou-se bom linearidade, exatidão e LD e LQ adequados em ambas as técnicas de análise.
12

Obsah rtuti v houbách rostoucích poblíž Horního Slavkova. / Mercury contents in mushrooms growing nearby Horní Slavkov.

BAŽILOVÁ, Štěpánka January 2008 (has links)
Contents of mercury were determined using AAS method (instrument AMA-254) in 130 fruiting body samples of 13 edible mushroom species. The mushrooms were collected from a forest of a historical area of tin mining. The highest mercury accumulation was observed in samples of Boletus edulis and Calocybe gambosa. Mercury content was highly comparable with concentrations observed in unpolluted sites.
13

Obsah rtuti v houbách z území poblíž závodu na výrobu střeliva a průmyslové střelnice / Mercury contents in mushrooms growing nearby a factory producing ammunition and an industrial shooting-range

BRÁZDOVÁ, Lenka January 2008 (has links)
Contents of mercury were determined using AAS method (instrument AMA-254) in 119 fruiting body samples of 41 mostly edible mushroom species. The mushrooms were collected from a forest near by the ammunition factory and its industrial shooting-range (fy Sellier & Bellot, Vlašim, Czech Republic). The highest mercury accumulation was observed in samples of Agaricus arvensis, Lepista nuda, Calocybe gambosa and Russu-la nigricans. Mercury content was highly comparable with concentrations observed in unpolluted sites.
14

Obsah rtuti v hubách z území poblíž nádrže Skalka / Mercury contents in mushrooms growing nearby a reservoir Skalka

SZABOVÁ, Martina January 2010 (has links)
Contents of mercury were determined using AAS method (instrument AMA-254) in 64 fruiting body samples of 15 edible mushroom species. The mushrooms were collected from a forest nearby a reservoir Skalka. The highest mercury accumulation was observed in a sample of Boletus edulis (15.5 mg/ kg dry matter). Mercury contents were highly comparable with concentrations observed in unpolluted sites. It can be therefore concluded that mercury contents in mushroom from the observed area do not represent any health risk.
15

Investigação de diferentes estratégias de preparo de amostras de sedimentos de rio para determinação de elementos-traço por espectrometria de absorção atômica

Mimura, Aparecida Maria Simões 27 February 2013 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2016-08-08T15:32:55Z No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-08-09T11:53:07Z (GMT) No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5) / Made available in DSpace on 2016-08-09T11:53:07Z (GMT). No. of bitstreams: 1 aparecidamariasimoesmimura.pdf: 1278299 bytes, checksum: 673e59e18120184eda18db151df38037 (MD5) Previous issue date: 2013-02-27 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / A determinação de elementos-traço em sedimentos tem recebido especial atenção no campo da ecologia e química ambiental. Tais espécies não são biodegradáveis e possuem a tendência de se acumular em organismos vivos e sedimentos, contaminando assim todo o ecossistema. Assim, os sedimentos podem atuar como um reservatório destas espécies e ser utilizados para investigar o histórico de poluição em certas áreas. Dentro deste contexto, o objetivo deste estudo foi desenvolver e otimizar um método de extração assistida por ultrassom para a determinação de Cr, Cu, Zn, Cd e Pb em sedimentos por espectrometria de absorção atômica. Vários procedimentos de extração foram estudados. Para otimizar as condições do procedimento de extração foi utilizado um planejamento fatorial fracionário. As condições ótimas para a extração foram: 0,1 g de sedimento, 7,0 mL de HF concentrado, 3,0 mL de HCl concentrado, 3 h de sonicação e temperatura do banho de ultrassom igual a 60 º C. Os resultados obtidos pela calibração externa e por adição de padrão foram concordantes a 95% de confiança para todos os analitos. As temperaturas de pirólise e atomização para as determinações de Cd e Pb por GF AAS foram estudadas. Na determinação de Pb foi utilizada a mistura de modificadores químicos (Pd e Mg). O método de extração proposto apresentou resultados adequados em relação à precisão (RSD < 10% com F AAS e < 20% com GF AAS). A exatidão foi confirmada através de estudos de adição e recuperação (com resultados de 89 a 107% de recuperação) e análise dos materiais de referência certificados Buffalo River e Marine Sediment (com recuperações na faixa de 74 a 106%). Comparado ao método oficial para a digestão de amostras de sedimentos, o tempo de preparo foi menor, favorecendo assim a frequência analítica, além do uso de menor volume de ácido, reduzindo os gastos e minimizando a geração de resíduos químicos. O método foi aplicado para a análise de amostras provenientes do Rio Doce e do Córrego Igrejinha. Foram encontrados resultados abaixo do máximo permitido pela legislação para as amostras do Rio Doce para todos os analitos, com exceção do Cr, que apresentou valores próximos ao nível máximo aceitável (90 mg kg-1). Já para as amostras do Córrego Igrejinha, todos os valores encontrados foram elevados, indicando um forte impacto ambiental na região. / The determination of trace elements in sediments has being receiving special attention in the field of ecology and environmental chemistry. Such species are not biodegradable and have a tendency to accumulate in living organisms and sediments, thus contaminating the entire ecosystem. Thus, sediment may act as a reservoir of these species and can be used to investigate the history of pollution in certain areas. Within this context, the aim of this study was to develop and optimize a method of ultrasound-assisted extraction for the determination of Cr, Cu, Zn, Cd and Pb in sediments by atomic absorption spectrometry. Several extraction procedures were studied. To optimize the extraction conditions a fractional factorial design were used. The optimum conditions for extraction were: 0.1 g of sediment, 7.0 mL concentrated HF, 3.0 mL concentrated HCl, 3 h of sonication time and ultrasound bath temperature equal to 60 ° C. The results obtained by external calibration and standard additions were consistent at 95% confidence level for all analytes. The pyrolysis and atomization temperatures for the determination of Cd and Pb by GF AAS were studied. In the determination of Pb was used the chemical modifiers (Pd and Mg). The proposed extraction method showed adequate results in terms of precision (RSD < 10% with F AAS and < 20% with GF AAS). The accuracy was confirmed by spike tests (with recoveries between 89107%) and by analyzing the certified reference materials Buffalo River and Marine Sediment (with recoveries in the range of 74 to 106%). Compared to the official method for the digestion of sediment samples, the preparation time was lower, thus favoring the analytical frequency, and the use of lower volume of acid, reducing costs and minimizing the generation of waste chemicals. The method was applied to the analysis of samples from the Rio Doce and Córrego Igrejinha. About the Rio Doce samples, the results were below those maximum permitted by legislation for all analytes, with the exception of Cr, which showed alarming values, very close to the maximum acceptable level (90 mg kg-1). About the samples from Córrego Igrejinha, all values were high, indicating a strong environmental impact in the region.
16

Avaliação e tratamento dos contaminantes emergentes ( Ácido Acetilsalicílico, Diclofenaco e Paracetamol ) utilizando processos oxidativos avançados

NAPOLEÃO, Daniella Carla 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T18:01:36Z (GMT). No. of bitstreams: 2 arquivo116_1.pdf: 1394719 bytes, checksum: 139c388c8b366e90a503d871c7e50d00 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O interesse da comunidade científica no estudo de micropoluentes é muito recente e tem aumentado a cada dia, uma vez que estas substâncias vêm causando alterações importantes no meio ambiente, interferindo no sistema endócrino de animais e de seres humanos. Logo, foi necessário classificar essas substâncias que receberam o nome de contaminantes emergentes, dentre os quais estão os fármacos de diferentes classes como: analgésicos, antiinflamatórios, drogas psiquiátricas, antilipêmicos, antibióticos além de outras substâncias largamente utilizadas no consumo doméstico. Pesquisadores do mundo todo buscam verificar a presença desses compostos em matrizes ambientais, como estações de tratamento de efluentes e rios, e propor tratamento para os mesmos. O uso de processos oxidativos avançados (POA) surge nesse cenário como uma tecnologia capaz de remover estes micropoluentes dos meios contaminados. O presente trabalho tem por objetivo avaliar, quantificar e tratar soluções aquosas com os contaminantes emergentes (CE): Ácido Acetilsalicílico (AAS), Diclofenaco e Paracetamol. Planejamento Fatorial 23 com ponto central foi utilizado para determinar a melhor condição de operacionalização. Soluções sintéticas foram preparadas com o princípio ativo dos três fármacos em estudo, quantificadas antes e após a aplicação do POA, através de análise por LC/MS IT-TOF. Para que fossem obtidos resultados consistentes, a metodologia utilizada para quantificação dos fármacos por análise cromatográfica acoplada a espectrometria de massas foi validada utilizando normas exigidas pelos órgãos competentes (ANVISA E INMETRO). Análise de Carbono Orgânico Total foi também realizada, contribuindo na determinação da cinética apresentada no processo de degradação. O Processo de Fotólise e os Processos Foto-Fenton e UV/H2O2 foram utilizados e comparados os seus resultados. O processo de Fotólise não apresentou um percentual de degradação significativa para os fármacos estudados, enquanto que o Processo Foto-Fenton conseguiu degradar de modo eficiente todos os fármacos alcançando percentuais de degradação superiores a 90,00%. Após submissão das amostras aos POA, foi realizada análise da concentração de peróxido residual não detectando presença de peróxido. A análise da conversão de carbono orgânico total apresentou melhor resultado (84,84%) para o processo UV/H2O2, o qual também conseguiu obter 100,00% de degradação dos compostos estudados. Portanto, a modelagem cinética foi elaborada para o processo UV/H2O2, que se comportou de modo eficiente tanto para a remoção dos compostos estudados, bem como para a conversão de carbono orgânico total. O modelo cinético agrupado em dois grupos de compostos, refratários e não refratários, foi adotado para descrever o perfil da concentração de COT residual, conseguindo representar de modo satisfatório o perfil da fração residual dos compostos orgânicos analisados
17

Speciační analýza toxikologicky významných forem arsenu: rozvoj a porovnání technik využívajících generování těkavých hydridù, s detekcí ICP MS / Speciation analysis of toxicologocally important forms of arsenic: development and comparison of hydride generation based methods with ICP-MS detection

Trojánková, Nikola January 2012 (has links)
Nowadays, arsenic is becoming an important pollutant in the environment. Chronic exposure to arsenic can cause number of serious diseases. Therefore, a development of analytical methods for trace and ultratrace speciation analysis- analysis of individual forms or phases in which As is found in the sample - is fully in place. This Thesis compares four methods of trace speciation analysis, with focus on limits of detection and quantification, and on comparison of results of analysis of river and sea water reference materials. Methods based on hydride generation with preconcentration by cryotrapping and AAS or ICP-MS detection, with limits of detection in ng or tenths of ng·dm-3 , are compared with procedures employing HPLC, with ICP-MS detection. The Thesis includes development and optimization of a pre-reduction step of postcolumn hydride generation with on-line pre-reduction of pentavalent arsenic species, in order to improve sensitivity of this method. Limits of detection around 10 ng·dm-3 are achieved. The results of analyses obtained by individual methods are in excellent agreement. Keywords: Arsenic, speciation analysis, hydride generation, atomic absorption spectrometry, inductively coupled plasma- mass spectrometry, high efficiency liquid chromatography, limits of detection.
18

Avaliação da concentração de metais e elementos traço em amostras de sedimento do reservatório Guarapiranga, Bacia do Alto Tietê, São Paulo, Brasil / Metal and trace element sediment assessment from Guarapiranga reservoir, alto tietê basin, São Paulo, Brasil

Guimarães, Guilherme Moura 15 June 2011 (has links)
O reservatório Guarapiranga está localizado na região metropolitana de São Paulo, Brasil, e é responsável pelo abastecimento de cerca de 20% das necessidades de água da população dessa região, aproximadamente 3,7 milhões de pessoas. Contudo, esse sistema tem apresentado significante degradação em sua qualidade de água, devido ao recebimento de esgotos domésticos não tratados e efluentes industriais. Nesse estudo amostras de sedimentos foram coletadas em cinco pontos ao longo do reservatório e a concentração total de alguns elementos maiores (Fe, K e Na), traço (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U, V e Zn) e terras raras (Ce, Eu, La, Lu, Nd, Sm, Tb e Yb) foram determinadas pela técnica de Análise por Ativação Neutrônica Instrumental (INAA). Utilizando-se a técnica de Espectrometria de Emissão Ótica com Plasma Acoplado Indutivamente (ICP OES) as concentrações dos elementos Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn foram determinadas após a digestão ácida dos sedimentos de acordo com a metodologia US EPA 3051. As determinações dos metais Cd e Pb foram feitas por espectrometria de absorção atômica com forno de grafite (GFAAS) e a de Hg total, por espectrometria de absorção atômica com geração de vapor frio (CVAAS). A validação das três metodologias analíticas, em termos de precisão e exatidão, foi feita por meio da análise de materiais de referência certificados. Os resultados obtidos por INAA foram comparados aos valores de referência do NASC (North American Shale Composite), UCC (Upper Continental Crust) e de solos coletados na região do parque da Guarapiranga. O fator de enriquecimento (FE) e o índice de geoacumulação (Igeo) foram calculados para esses dados. As concentrações dos metais obtidos por ICP OES e AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotados pela CETESB. Os resultados foram também comparados aos valores de referência regionais (VRR) de sedimentos límnicos da Bacia do Alto Tietê. A partir desses dados foi possível realizar uma avaliação do acúmulo de metais e elementos traço nos sedimentos do reservatório e verificar a possibilidade desses elementos interferirem, adversamente, na biota e na qualidade da água desse ambiente. / The Guarapiranga Reservoir, located in São Paulo metropolitan region, Brazil, is responsible for supplying about 20% of the entire populations water needs of this region or approximately 3.7 million people. However, this system has shown significant degradation in water quality, due to untreated domestic sewage and industrial effluents. In this study sediment samples were collected at five points along the reservoir and total concentration of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U, V and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements were determined by instrumental neutron activation analysis (INAA). By inductively coupled plasma optical emission spectrometry (ICP OES) the concentrations of Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn were determined after digestion procedure following US EPA 3051 methodology. The concentrations of metals Cd and Pb were determined by graphite furnace atomic absorption spectrometry (GFAAS) and total Hg by cold vapor atomic absorption spectrometry (CVAAS). Methodology validation according to precision and accuracy was performed by reference materials analyses for the three different analytical techniques used. Multielemental results obtained by INAA were compared to NASC (North American Shale Composite), Upper Continental Crust (UCC) and soil from Guarapiranga park values. The Enrichment Factor (EF) and Geoaccumulation Index (Igeo) were also evaluated for these data. Metal concentration results by ICP OES and AAS in the samples were compared to the TEL and PEL oriented values established by the Canadian Council of Ministers of the Environment and also adopted by CETESB (Environmental Protection Agency of the São Paulo State). The results were also compared to regional reference values (VRR) of limnic sediments from the Alto Tietê Basin. From these data an assessment of metal and trace element accumulated in the sediments from the reservoir was carried out and the possibility of these elements interfering adversely on biota and water quality of this environment.
19

Laser induced breakdown spectroscopy (LIBS) applied to the quantification of elements in fertilizers / Laser Induced Breakdown Spectroscopy (LIBS) applied to the quantification of elements in fertilizer

Cervantes, Cesar 16 February 2017 (has links)
A capacidade do instrumento Laser Induced Breakdown Spectroscopy (LIBS) foi investigada para a possibilidade de atuar como uma ferramenta de quantificação. Um instrumento de baixo custo fechado do dispositivo de acoplamento de cargas (CCD) foi utilizado a fim de quantificar (K), (Ca), (Mn), (Mg), e (Cu) presente em 26 amostras de fertilizantes constituídos de diferentes matrizes, alguns fosfato de organo-mineral e outros de material inorgânico (quantificação de elementos presentes em fertilizante organominerais nunca tinha acontecido). Duas técnicas de referências foram utilizadas para validar as habilidades de quantificação: Plasma Acoplado Indutivo-Espectroscopia de Emissão Ótica (ICP-OES) e Espectroscopia de Absorção Atômica (AAS). O melhor pico representando cada elemento foi encontrado para produzir a melhor correlação entre cada pixel CCD e a concentração de elementos obtidos a partir das técnicas de referência. O pico mais adequado de LIBS foi tratado com um procedimento de normalização, a fim de corrigir os efeitos de matriz e as pequenas flutuações no plasma. Após o pico produzido por LIBS ser normalizado, foi linearmente montado contra os dados das duas técnicas de referência e duas curvas de calibração para cada um dos elementos foram construídas. Quando o procedimento de normalização não foi aplicado, valores de R-quadrado diminuiu entre 0,1-0,2 em quase todos os elementos. No entanto, entre os resultados produzidos pelas duas curvas de calibração, após o procedimento de normalização ser aplicado, os valores de correlação R-quadrado variaram de 0,8-0,98, o que foi considerado adequado para os elementos de interesse. O LOD para LIBS também foi calculado e verificou-se que quando os valores estavam abaixo do limite de determinação, a validade de LIBS como uma ferramenta de quantificação diminuiu. Além disso, uma análise de erro de validação cruzada foi feita com LIBS-ICP e LIBS-AAS, o que originou valores de erro de 22% - 28% para alguns dos elementos, quando todas as amostras foram incluídas. Mas quando as amostras abaixo do LOD foram excluídas, aqueles valores de erro desceram significativamente, e resultou na gama de 7% - 20%. Uma análise de validação cruzada também foi feita para as concentrações dos elementos determinados pelas técnicas de referência e esses resultados produziram valores de erro variando de 9% - 23%. As semelhanças entre os valores de erro LIBS e os valores de erro das técnicas de referência, dá credibilidade para a capacidade de LIBS para atuar como uma ferramenta para a quantificação de elementos presentes em fertilizantes compostos de diferentes matrizes. / The ability of the instrument Laser Induced Breakdown Spectroscopy (LIBS) was investigated for the possibility of acting as a quantification tool of analysis. A low-cost gated charged coupled device (CCD) was used in order to quantify (K), (Ca), (Mn), (Mg), and (Cu) present in 26 fertilizer samples made up of different matrixes, some of organic-mineral phosphate and others of inorganic material; evaluation of elements in organomineral fertilizers had never been done by LIBS. Two reference techniques were used in order to validate the quantification abilities: Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) and Atomic Absorption Spectroscopy (AAS). The best peak representing each element was found by finding the best correlation between each CCD pixel and the element concentration obtained from the reference techniques. The most appropriate peak from LIBS was treated with a normalization procedure in order to correct for physical matrix effects and small plasma fluctuations. After the LIBS peak was normalized, it was linearly fitted against the data from the two reference techniques, thus two calibration curves for each element were built. When the normalization procedure was not applied, R-squared values decreased between 0.1 - 0.2 in almost all the elements. However, amongst the results of the two calibration curves after the normalization procedure was applied, R-squared correlation values ranged from 0.8-0.98, which were considered adequate for the elements of interest. The LOD for LIBS was also calculated and it was found that when values were below the LOD, the validity of LIBS as a quantification tool decreased. Moreover, a cross-validation error analysis was done with LIBS-ICP and LIBS-AAS, which yielded error values of 22% - 28% for some of the elements when all samples were included, but when samples below the LOD were excluded, those error values went down significantly, and resulted within the range of 7% - 20%. A cross-validation analysis was also done for the element concentrations determined by the reference techniques and those results yielded error values ranging from 9%- 23%. The similarities between the LIBS error values and the reference techniques error values, gives credibility to the ability of LIBS to act as a tool for quantifying elements in fertilizers composed of different matrixes.
20

Preparação e caracterização de um material de referência de peixe / Preparation and characterization of the fish reference material

Ulrich, João Cristiano 01 March 2011 (has links)
Os materiais de referência certificados (MRCs) desempenham importante papel na obtenção de resultados de medições rastreáveis ao Sistema Internacional de Unidades (SI), por meio de uma cadeia contínua de comparações. Dessa forma, a demanda por novos materiais de referência certificados (MRC) aumenta a cada dia em todas as áreas do conhecimento. A disponibilidade de materiais de referência, principalmente no Brasil, ainda é incipiente, face a demanda que excede em muito a variedade disponível desses materiais. Entre as diversas áreas carentes de materiais de referência, destaca-se a área de alimentos pela importância desses produtos na balança comercial do país. A certificação de produtos alimentícios, destinados tanto para exportação como para o consumo interno, requer metodologias de análise que ofereçam resultados precisos e exatos a fim de assegurar a qualidade do produto. Este trabalho descreve a produção e certificação de um material de referência na matriz peixe em mercúrio e metilmercúrio. O estudo reúne desde a etapa de seleção do material, preparação, desenvolvimento dos estudos de homogeneidade e estabilidade e a caracterização. A certificação foi realizada por meio de medições utilizando duas técnicas analíticas, a Espectrofotometria de Absorção Atômica (AAS) com sistema de injeção em fluxo e geração de vapor frio (FIA-CV-AAS) e a Diluição Isotópica aplicada a Espectrometria de Massas (IDMS), sendo este um método primário. Neste trabalho as normas da série ISO 30 (ABNT 3034) e ISO Guide 35 foram utilizadas como base para a preparação e caracterização do material. Para o cálculo de incertezas foi utilizado o GUM e o guia Eurachem. Como resultado, foi produzido e certificado um lote do material em relação ao teor de mercúrio (Hg = 0,271±0,057 &mu;g g-1) e metilmercúrio (MeHg = 0,245±0,038 &mu;g g-1), além de valores informativos de chumbo e arsênio. / The certified reference materials (CRMs) play an important role in obtaining measurement results traceable to the International System of Units, through an unbroken chain of comparisons. Thus, the demand for new certified reference materials (CRMs) increases every day in all areas of knowledge. The availability of reference materials, mainly in Brazil is still incipient, given that the demand far exceeds the available variety of these materials. The amount of certified reference materials available in the country is insufficient to meet the need of the scientific community and demands for development of new methodologies. Among the many areas in need of reference materials, we highlight the importance for the food trade balance for these products within the country. The certification of food products, intended both for export and for domestic consumption, requires analysis methods that provide precise and accurate results to ensure product quality. This paper describes the preparation and certification of a reference material in the fish matrix in mercury and methylmercury. The study brings together since the stage of material selection, preparation, development of homogeneity and stability studies and characterization. The certification was performed by means of measurements using two analytical techniques, flow injection analysis - cold vapor atomic absorption spectrometry (FIA-CV-AAS) and isotope dilution applied to mass spectrometry (IDMS), which is a primary method. In this work the standards of the ISO 30 (ABNT 30-34) and ISO Guide 35 was used as the basis for the preparation and characterization of the material. For the calculation of uncertainties was used the GUM and Eurachem guide. As a result, was produced and certified a lot of material in relation to the concentration of mercury (Hg = 0.271 ± 0.057 mg g-1) and methylmercury (MeHg = 0.245 ± 0.038 mg g-1), and informational values of lead and arsenic .

Page generated in 0.0301 seconds