• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 29
  • 16
  • 10
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 171
  • 39
  • 30
  • 27
  • 23
  • 23
  • 22
  • 18
  • 18
  • 18
  • 18
  • 18
  • 18
  • 18
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estratégias analíticas para análise de especiação de arsênio, antimônio e selênio em amostras ambientais usando amostragem por suspensão e HG AAS

Macedo, Samuel Marques January 2010 (has links)
101 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-05T14:35:00Z No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-09T12:37:12Z (GMT) No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) / Made available in DSpace on 2013-05-09T12:37:12Z (GMT). No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) Previous issue date: 2010 / CNPq / Um procedimento analítico simples e rápido foi desenvolvido para a determinação de As em amostras de sedimento e determinação de As, Sb e Se em amostras de material particulado atmosférico por geração de hidreto acoplado ao espectrômetro de absorção atômica (HG-AAS). Procedimentos de amostragem de suspensão foram avaliados quanto a determinação de As, Sb e Se inorgânicos por geração de hidreto acoplado a AAS, usando HCl e sonicação por 30 min. As amostras foram preparadas com KI e ácido ascórbico para determinação de As e Sb total e com HCl 8 mol L-1 em banho de ultra-som para a determinação de Se total. Para a determinação seletiva de As (III) foi usado tampão ácido cítrico/citrato, para Sb (III) foi usado ácido cítrico e Se (IV) foi determinado considerando que Se (VI) não forma hidreto. Suspensões das amostras foram tratadas com NaBH4 para obter o hidreto correspondente. O procedimento foi otimizado para taxa de fluxo de NaBH4, concentração de NaBH4 e HCl usando planejamento fatorial dois níveis completo e também um planejamento Box-Behnken para As e Sb e usando planejamento fatorial dois níveis completo para Se. A preparação das suspensões com HCl em ultra-som permitiu a determinação de As, Sb e Se total com limites de detecção de 0,1, 0,05 e 0,1 μg L−1, respectivamente e As (III), Sb (III) e Se (IV) com limites de detecção de 0,3, 0,1 e 0,3 μg L−1 respectivamente. A exatidão do método foi confirmada pela análise de materiais de referência certificado de sedimento marinho (MESS-2 e MESS-3) e poeira urbana (1649a), ao passo que o procedimento permite a calibração com padrões aquosos. Concentrações encontradas nas amostras variaram de 2,81 a 5,38 mg kg−1 para As total (RSD < 5 %), de 0,59 a 1,25 mg kg−1 para As (III) (RSD < 8%), em material particulado atmosférico variaram de 9,1 a 19,0 ng m−3 para As total (RSD < 4 %), de 2,7 a 11,0 ng m−3 As (III) (RSD < 5 %) e para Sb total variaram de 0,49 a 0,63 ng m−3 (RSD < 9 %). Nas amostras analisadas de material particulado atmosférico, as concentrações de Sb (III) ficaram abaixo do limite de quantificação. O selênio foi determinado somente no SRM 1649a. / Salvador
42

Adequação e verificação de procedimentos para determinação de mercúrio em amostras de fígado e rim de rato utilizando a técnica CV-GF AAS

SANTOS, A. E. 25 August 2014 (has links)
Made available in DSpace on 2016-08-29T15:35:36Z (GMT). No. of bitstreams: 1 tese_8105_André Eliziário dos Santos.pdf: 1636286 bytes, checksum: c6a5766e7cd00151e9c2336f4121dcd9 (MD5) Previous issue date: 2014-08-25 / O mercúrio é um elemento que ainda necessita constante monitoramento devido sua capacidade tóxica em concentrações em níveis de traço com possibilidade de contaminação e exposição por uma variedade de formas e compostos presentes no ambiente. Esse estudo possuiu como objetivo a obtenção de um procedimento simplificado e eficiente para a determinação de teores de mercúrio em tecidos de rato Wistar a partir da otimização de um método de determinação, utilizando um sistema de geração de vapor frio acoplado a espectrometria de absorção atômica com forno de grafite (CV-GF AAS). Houve a comparação entre métodos de digestão, comparação de métodos de amalgamação, otimização, verificação do método a partir da obtenção de figuras de mérito e análise de amostras de fígado e rins de ratos tratados com exposição crônica ao mercúrio. Os resultados comprovaram que o método de digestão em bloco digestor, a utilização de amalgamação por recobrimento de tubo em ouro em conjunto com rede de ouro e adição pré-análise à solução de simeticona e isopropanol apresentou os melhores resultados, com teores de recuperação médios entre 92 e 114 %, viabilizando a utilização do procedimento proposto.
43

Adequação e verificação de procedimentos para determinação de mercúrio em amostras de fígado e rim de rato utilizando a técnica CV-GF AAS

Santos, André Eliziário dos 25 July 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2014-12-12T19:36:28Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Andre Elizario dos Santos.texto completo.pdf: 1636329 bytes, checksum: 2a6ae08a2a5db20270e59c8548e445a5 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2014-12-19T18:08:25Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Andre Elizario dos Santos.texto completo.pdf: 1636329 bytes, checksum: 2a6ae08a2a5db20270e59c8548e445a5 (MD5) / Made available in DSpace on 2014-12-19T18:08:25Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Andre Elizario dos Santos.texto completo.pdf: 1636329 bytes, checksum: 2a6ae08a2a5db20270e59c8548e445a5 (MD5) Previous issue date: 2014 / O mercúrio é um elemento que ainda necessita constante monitoramento devido sua capacidade tóxica em concentrações em níveis de traço com possibilidade de contaminação e exposição por uma variedade de formas e compostos presentes no ambiente. Esse estudo possuiu como objetivo a obtenção de um procedimento simplificado e eficiente para a determinação de teores de mercúrio em tecidos de rato Wistar a partir da otimização de um método de determinação, utilizando um sistema de geração de vapor frio acoplado a espectrometria de absorção atômica com forno de grafite (CV-GF AAS). Houve a comparação entre métodos de digestão, comparação de métodos de amalgamação, otimização, verificação do método a partir da obtenção de figuras de mérito e análise de amostras de fígado e rins de ratos tratados com exposição crônica ao mercúrio. Os resultados comprovaram que o método de digestão em bloco digestor, a utilização de amalgamação por recobrimento de tubo em ouro em conjunto com rede de ouro e adição pré-análise à solução de simeticona e isopropanol apresentou os melhores resultados, com teores de recuperação médios entre 92 e 114 %, viabilizando a utilização do procedimento proposto. / Mercury is an element that still needs constant monitoring because it is highly toxic at trace-level concentrations, with possibility exposure and contamination by a variety of forms present in the environment. Thus, the aim of this work was adapt and verify a simple and efficient procedure for mercury determination in Wistar rat tissues using cold vapor generation, pre-concentration in graphite furnace and analysis by atomic absorption spectrometry (CV-GF AAS). They were made comparison of amalgamation methods, procedure optimization, verification of merit figures and analysis of liver and kidneys of chronically treated rat. The best results were obtained using the hot block digestion method as sample pre-treatment and gold coated tube combined with and net of gold for amalgamation. It was necessary to use dichromate, isopropanol and simeticone pre-analysis. Procedure accuracy was verified through recovery tests at five concentration (between 92 and 114 %), enabling the use of the proposed procedure.
44

Bioackumulering av tungmetaller i vildsvin (Sus scrofa) : -analys av biotillgängligheten av bly och kadmium i vildsvinslever

Axelsson, Helena, Spångberg, Annica January 2018 (has links)
As the wild boar population increases, so does the consuming of wild boar meat. Often with the belief that this is much healthier than conventional meat. International studies have shown that wild boar meat is more likely to contain higher concentrations of soil pollutions than other game meat. The aim of this study was therefore to analyze the concentrations of lead (Pb) and cadmium (Cd) in the liver of free living wild boars (Sus scrofa), located in the south of Sweden. Samples were taken from 10 wild boars during the hunting season of spring, 2018. The lead and cadmium concentrations in wild boar livers were determined by AAS- atomic absorption spectroscopy. Our result shows a higher uptake for cadmium than lead. Cadmium also seem to increase with age in wild boars due to bioaccumulation. However, 7 out of 10 livers exceeded the maximum limit for food safety standards regarding lead (0,10 mg/kg) and 2 out of 10 for cadmium (0,50 mg/kg). Therefore, the consumer should practice vigilance, especially for wild boar meat originating from areas known to be contaminated.
45

Biodostupnost kovových spécií ve vodním ekosystému / Bioavailability of metals species in water ecosystem

Tandler, Ágnes January 2012 (has links)
Koncentrace volných kovových iontů je často jen malou částí celkové koncentrace kovu v prostředí. Přes tento malý obsah, je ve většině případů koncentrace volných kovových iontů klíčovým faktorem při určování biodostupnosti a toxicity pro organizmus. Membránová technika Donnan se používá k měření koncentrace volných kovových iontů a v této diplomové práci je ověřena pro směsi kovů (Pb + Cu) při absenci a přítomnosti malých organických ligandů. Olovo a měď jsou environmentálně důležité kovy díky své toxicitě a rozdílným vazebným vlastnostem ve vztahu ke studovaným ligandům.
46

[en] TOTAL SELENIUM IN TISSUES OF FOUR DIFFERENTS MARINE ORGANISMS FROM GUANABARA BAY, RJ, BRAZIL / [pt] SELÊNIO TOTAL EM TECIDOS DE QUATRO DIFERENTES ORGANISMOS MARINHOS DA BAÍA DE GUANABARA, RJ, BRASIL

TERCIA GUEDES SEIXAS 03 January 2005 (has links)
[pt] Neste estudo foram determinadas as concentrações de selênio total (TSe) no músculo, fígado e gônada de três espécies de peixe (Mugil liza - tainha, peixe planctívoro; Bagre spp. - bagre, peixe onívoro e Micropogoni as furnieri - corvina, peixe carnívoro) e também, nos tecidos moles de uma espécie de mexilhão (Perna perna) coletados na Baía de Guanabara. TSe foi determinado por GF-AAS equipado com corretor Zeeman. O modificador químico foi o Pd. A metodologia analítica apresentou ótima precisão e exatidão quando comparada com amostras certificadas, DORM-2 e NIST 2976 e também, através de uma intercalibração laboratorial com amostras de peixe realizada entre dois laboratórios: Radioisótopos na UFRJ e um de referência na Finlândia. Dentre todos os tecidos, o fígado foi o que apresentou as maiores TSe em todas as espécies de peixe. Os peixes carnívoros e planctívoros apresentaram concentrações similares no fígado. O peixe carnívoro foi a espécie que apresentou as maiores TSe no músculo. O músculo parece ser o único tecido que sofreu influência direta do hábito alimentar. Nos peixes, TSe no músculo apresentou uma correlação significativa e positiva com o comprimento total, idade e conseqüentemente, com o tempo de exposição ao meio ambiente. Os mexilhões apresentaram uma correlação significativa entre TSe nos tecidos moles e o índice de condição (IC). Segundo a literatura científica, este trabalho é o segundo do gênero a ser realizado no Brasil. Sendo que este correspondeu ao primeiro trabalho em que se comparou TSe entre os diversos órgãos e tecidos da biota aquática com diferentes hábitos alimentares. / [en] This study assessed total selenium concentrations (TSe) in the muscle tissues, liver and gonads samples of three fish species (Mugil liza - mullet, planktivorous fish; Bagre spp. - catfish, omnivorous fish and Micropogonias furnieri - Atlantic croaker, carnivorous fish) and also in the soft tissues of a mussel (Perna perna) from Guanabara Bay. TSe in the digested samples was analyzed by GF-AAS using Zeeman background correction. Pd was the chemical modifier. The analytical methodology presented high precision and accuracy when tested with certified reference materials, DORM-2 and NIST 2976, and also through intercomparison between two laboratories, Laboratório de Radioisótopos (UFRJ) and a reference laboratory from a Finish National Public Health Institute, using fish samples. The liver samples of all studied fish species presented the highest TSe. Carnivorous and planktivorous fishes presented similar TSe in their liver. Carnivorous fish showed the highest TSe in the muscle. The muscle was the only tissue that presented a direct influence of the feeding habits. Carnivorous and planktivorous fishes showed high positive correlations between TSe in the muscle and their total length, age and consequently, with the exposure time at environment. A significant correlation was observed between the selenium concentration in the mussel soft tissues and the condition index (IC). We verified in the scientific literature that our study was the second one conducted in Brazil. Furthermore it was the first one that compared the total selenium concentrations in organs and tissues of several aquatic organisms with different feeding habits.
47

Caracterização química elementar e proteica da polpa de graviola / Elemental and protein determinations in graviola pulp

Kelmer, Gislayne Aparecida Rodrigues 27 April 2012 (has links)
No presente trabalho foram desenvolvidos métodos para a determinação de Al, B, Ba, Ca, Co, Cu, Cr, Fe, K, Li, Mg, Mn, P, S, Si, Sn, Sr, Ti, V e Zn por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e As, Cd, Pb e Se por espectrometria de absorção atômica com forno de grafite e detecção simultânea (SIMAAS) em polpa de graviola (Annona muticata L.). A determinação de proteínas bem como a estimativa da presença de Fe, Cu, Mn e Zn a elas associados também foram investigados. Para as determinações elementares foi utilizada polpa de graviola, seca em estufa a 50° C, digeridas com mistura oxidante diluída (2 mL HNO3 + 1 mL H2O2 + 3 mL H2O) e aquecimento em forno de micro-ondas com frasco fechado. A avaliação da exatidão dos métodos foi feita a partir da análise de material de referência certificado (Citrus Leaves SRM 1572, NIST) e os resultados concordaram, para maioria dos elementos, em 95% como intervalo de confiança, quando aplicado o teste t-Student. A polpa também foi submetida a diferentes pré-tratamentos: 1) secagem por liofilização e moagem em moinho criogênico; 2) homogeneização da polpa in natura em moinho de facas; e 3) secagem em estufa a 50 °C e moagem em almofariz e pistilo. Nessa etapa, o objetivo foi avaliar a influência dos procedimentos de pré-tratamento nas extrações de proteínas. Massas de amostra (~5 g), após extração lipídica, foram submetidas à agitação (1 h) com 0,5 mol L-1 NaOH, tampão Tris-HCl (pH 7,5), 0,5 mol L-1 HCl e tampão CO32-/HCO31- (pH 10) para extração de proteínas. Os extratos foram analisadas por ICP OES para determinação de Cu, Fe, Mn e Zn e proteínas pelo método de Bradford. Alíquotas dos extratos foram submetidas à etapa de limpeza (clean up) utilizando acetona em banho de gelo, 0,5 mol L-1 HCl e 20% m v-1 de TCA para precipitação de proteínas. Somente acetona em banho de gelo foi eficiente na precipitação das proteínas. Os precipitados foram redissolvidos em tampão Tris-HCl e submetidos a separação por cromatografia de exclusão por tamanho e detecção por espectrofotometria UV (SEC-UV), a 280 nm. As proteínas totais nas amostras foram estimadas por análise elementar (CHN) e, em solução, pelo método de Bradford. Independente da solução extratora utilizada, o processo de liofilização e moagem criogênica foi o que proporcionou maior quantidade de proteínas extraídas. Porém, após a precipitação com 80 % v v-1 de acetona, maior quantidade de proteínas foram precipitadas da amostra in natura, indicando possíveis alterações durante a liofilização e secagem. Em todos os extratos submetidos a análises por SEC-UV foi observado maior quantidade de compostos de baixo peso molecular (< 6,5 kDa). Melhor eficiência de extração de proteínas e dos elementos Cu, Fe, Mn e Zn foi observada na extração com NaOH. Maiores concentrações dos elementos extraídos foram encontradas nas amostras in natura e menores nas amostras secas em estufa com moagem em almofariz e pistilo. / In this work methods for the determination of Al, B, Ba, Ca, Co, Cu, Cr, Fe, K, Li, Mg, Mn, P, S, Si, Sn, Sr, Ti, V and Zn by inductively coupled plasma optical emission spectrometry (ICP OES) and As, Cd, Pb e Se by simultaneous graphite furnace atomic absorption spectrometry (SIMAAS) in graviola pulp (Annona Muricata L.) were developed. The determination of proteins and the possible presence of Fe, Cu, Mn and Zn associated to them were also investigated. For elements determination, graviola pulp was dry in wood stove at 50%C and digested using diluted oxidant mixture (2 mL HNO3 + 1 mL H2O2 + 3 mL H2O) in closed-vessel microwave oven. The accuracy and precision of the methods were done by certified reference material analysis (Citrus Leaves SRM 1572, NIST), and the obtained results were in accordance at 95%, according Student-t test. The graviola pulp was also submitted to different pretreatments: 1) lyophilization and cryogenic grinding; 2) homogenization of the in natura sample in a knife mill; and 3) drying in wood stove at 50%C and grinding in a mortar. The objective of this step was to evaluate the influence of sample pretreatment on the protein extractions. After lipid extraction, sample masses (~5 g) were shacked (1 h) with 0.5 mol L-1 NaOH, Tris-HCl buffer (pH 7.5), 0.5 mol L-1 HCl and CO32-/HCO31- buffer (pH 10) for protein extraction. The extractants solutions were analyzed for Cu, Fe, Mn and Zn determinations by ICP OES and for protein determinations by Bradford method. A clean up step, using acetone in ice-bath, 0.5 mol L-1 of HCl and 20% m v-1 of TCA was used for protein precipitation. In this way, only acetone in ice-bath was efficient for precipitation. After that, precipitates were dissolved in Tris-HCl buffer and analyzed by size exclusion chromatography with UV detection (SEC-UV), at 280 nm. Total protein contents in the sample and in the extracting solutions were determined by elemental analysis (CHN) and Bradford method, respectively. For all extracting solutions, the lyophylization and cryogenic grinding procedure showed the best efficiency for proteins extraction. However, after precipitation with acetone 80 v v-1, higher amount of proteins were observed for in natura sample, indicating some structure protein modification during the lyophylization or drying pretreatment steps. In general, low molecular weight compounds (< 6,5 kDa) were observed for all extracting solutions. The NaOH extractor showed much better efficiency for proteins and Cu, Fe, Mn and Zn extraction. Higher concentration of the extracting elements were found for in natura samples and lower for drying in wood stove at 50%C and grinding in a mortar.
48

Propostas de métodos para determinações de As, Cd, Cr(III), Cr(VI), Hg, Ni, Pb e Se em fertilizantes minerais por AAS e ICP OES / Proposed of methods for the determination of As, Cd, Cr(III) Cr(VI), Hg, Ni, Pb and Se in mineral fertilizers by AAS and ICP OES

Kelmer, Gislayne Aparecida Rodrigues 18 November 2016 (has links)
O objetivo deste trabalho foi o desenvolvimento de métodos visando às determinações de As, Cd, Cr(III), Cr(VI), Hg, Ni, Pb e Se em fertilizantes minerais por espectrometria de absorção atômica com atomização em forno de grafite (GF AAS) e espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Foi empregado Material de Referência Certificado de fertilizante inorgânico (SRM® 695, NIST) e amostra de candidato a Material de Referência Rastreado (MRR), mix-micro, cedida pelo LANAGRO de Goiânia. A análise da amostra MRR, obtida por fluorescência de Raios-X (XRF), mostrou a complexidade dessa matriz devido, principalmente à presença de elevados teores de Al, Si, Fe, Ti, Mn e Ca. Foram feitas otimizações do ICP OES visando condições robustas para determinações de As, Cd, Cr, Ni e Pb em soluções com nebulização direta e As, Hg e Se com nebulização combinada com geração de vapor. Foi verificado que os métodos de preparo de amostras, 3051 e 3052 recomendados pela USEPA (Agência de Proteção Ambiental dos Estados Unidos), podem ser aplicados apenas para determinação de As, Cd e Pb. Elementos fortemente ligados a matriz, como Cr e Ni, não foram quantitativamente extraídos. A digestão pelo método 3052 na presença de H3BO3 alterou o erro relativo de -36% para -15% para o Cr e a concentração de Ni também foi maior nesse caso. Para a determinação simultânea de As, Hg e Se no ICP OES por geração de vapor (VG-ICP OES), foi utilizado um procedimento de pré-redução para Se(VI), envolvendo aquecimento a 90°C das soluções em meio de HCl 6 mol L-1. A etapa adicional para redução de Se não prejudicou as determinações de As e Hg. A geração de vapor para a determinação simultânea dos elementos ocorreu com a separação gás-líquido dentro da câmara ciclônica. A extração usando banho e sonda ultrassônica, na presença de ácidos diluídos (HCl, HNO3, H3PO4), não influenciou consideravelmente as determinações de As, Cd, Cr, Ni e Pb por ICP OES e Se por GF AAS. O borbulhamento de ar atmosférico foi suficiente para uma eficiência de extração comparável aos dispositivos ultrassônicos. A utilização de pequenos volumes de ácidos concentrados mostrou ser adequada para melhorar a eficiência de extração, principalmente para o Ni. O HCl concentrado foi a condição mais adequada para a extração. Com relação à determinação de Cr(VI), foram estudadas diferentes soluções extratoras alcalinas e, além do uso do banho termostático, foi avaliada a extração utilizando ultrassom. Devido à complexidade das amostras de fertilizantes, estratégias foram adotadas para adequar o método da difenilcarbazida a essa matriz. Além da espectrofotometria de absorção molecular na região do visível, a determinação do teor de Cr(VI) nos extratos foi feita por GF AAS e as concentrações de Cr(VI) estavam abaixo do limite de detecção do método. / The aim of this work was the development of methods for the determination of As, Cd, Cr(III) Cr(VI), Hg, Ni, Pb and Se in mineral fertilizers by graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was employed a Certified Reference Material (SRM® 695 - Trace elements in multi-nutrient fertilizer) from the National Institute of Standards and Technology (NIST) and an in-lab candidate of Reference Material (MR), mix-micro sample (raw material used in formulation of mineral fertilizers to improve micronutrient content) provided by LANAGRO (Laboratório Nacional Agropecuário, Goiania, Brazil). The analysis of MR sample by X-ray fluorescence (XRF) showed the matrix complexity, mainly due to the presence of high levels of Al, Si, Fe, Ti, Mn and Ca. The ICP OES optimization was carried out aiming rubust conditions for As, Cd, Cr, Ni and Pb determination by direct nebulization solutions, and As, Hg and Se with nebulization combined with vapor generation. It was found that the methods of sample preparation, USEPA 3051 and 3052 (US Environmental Protection Agency), can be applied only for the determination of As, Cd and Pb. Elements that are strongly bound to the matrix, such as Cr and Ni were not quantitatively extracted. Digestion by method USEPA 3052 in the presence of H3BO3 alter the relative error from -36% to -15% for Cr and Ni concentration was also higher in this case. For the simultaneous determination of As, Hg and Se by ICP OES vapor generation (VG-ICP OES), a pre-reduction procedure for Se (VI) was necessary, involving heating at 90 °C of the solutions in HCl 6 mol L-1. The additional step for Se reduction did not impair Hg and As determination. The vapor generation for simultaneous elements determination with the gas-liquid separation occurring within the cyclonic spray chamber. The extraction using bath and ultrasonic probe in the presence of dilute acids (HCl, HNO3, H3PO4) did not influence considerably the determination of As, Cd, Cr, Ni and Pb by ICP OES and Se by GF AAS. Only atmospheric air bubbling was enough for an efficient extraction providing results comparable to ultrasonic devices. The use of small volumes of concentrated acids proved to be suitable for improving extraction efficiency, particularly for Ni. Concentrated HCl was the most suitable condition for extraction. For Cr(VI) determination, various solutions and alkaline extractant was studied, and the use of the thermostatic bath and ultrasound bath was evaluated. Due to the complexity of fertilizer samples, strategies were adopted to adapt diphenylcarbazide method to this matrix. Besides Cr(VI) determination in extracts by molecular absorption spectrophotometry in the visible region, it was also performed by GF AAS and Cr(VI) concentration was below limit of detection of the method.
49

Propostas de métodos para determinações de As, Cd, Cr(III), Cr(VI), Hg, Ni, Pb e Se em fertilizantes minerais por AAS e ICP OES / Proposed of methods for the determination of As, Cd, Cr(III) Cr(VI), Hg, Ni, Pb and Se in mineral fertilizers by AAS and ICP OES

Gislayne Aparecida Rodrigues Kelmer 18 November 2016 (has links)
O objetivo deste trabalho foi o desenvolvimento de métodos visando às determinações de As, Cd, Cr(III), Cr(VI), Hg, Ni, Pb e Se em fertilizantes minerais por espectrometria de absorção atômica com atomização em forno de grafite (GF AAS) e espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Foi empregado Material de Referência Certificado de fertilizante inorgânico (SRM® 695, NIST) e amostra de candidato a Material de Referência Rastreado (MRR), mix-micro, cedida pelo LANAGRO de Goiânia. A análise da amostra MRR, obtida por fluorescência de Raios-X (XRF), mostrou a complexidade dessa matriz devido, principalmente à presença de elevados teores de Al, Si, Fe, Ti, Mn e Ca. Foram feitas otimizações do ICP OES visando condições robustas para determinações de As, Cd, Cr, Ni e Pb em soluções com nebulização direta e As, Hg e Se com nebulização combinada com geração de vapor. Foi verificado que os métodos de preparo de amostras, 3051 e 3052 recomendados pela USEPA (Agência de Proteção Ambiental dos Estados Unidos), podem ser aplicados apenas para determinação de As, Cd e Pb. Elementos fortemente ligados a matriz, como Cr e Ni, não foram quantitativamente extraídos. A digestão pelo método 3052 na presença de H3BO3 alterou o erro relativo de -36% para -15% para o Cr e a concentração de Ni também foi maior nesse caso. Para a determinação simultânea de As, Hg e Se no ICP OES por geração de vapor (VG-ICP OES), foi utilizado um procedimento de pré-redução para Se(VI), envolvendo aquecimento a 90°C das soluções em meio de HCl 6 mol L-1. A etapa adicional para redução de Se não prejudicou as determinações de As e Hg. A geração de vapor para a determinação simultânea dos elementos ocorreu com a separação gás-líquido dentro da câmara ciclônica. A extração usando banho e sonda ultrassônica, na presença de ácidos diluídos (HCl, HNO3, H3PO4), não influenciou consideravelmente as determinações de As, Cd, Cr, Ni e Pb por ICP OES e Se por GF AAS. O borbulhamento de ar atmosférico foi suficiente para uma eficiência de extração comparável aos dispositivos ultrassônicos. A utilização de pequenos volumes de ácidos concentrados mostrou ser adequada para melhorar a eficiência de extração, principalmente para o Ni. O HCl concentrado foi a condição mais adequada para a extração. Com relação à determinação de Cr(VI), foram estudadas diferentes soluções extratoras alcalinas e, além do uso do banho termostático, foi avaliada a extração utilizando ultrassom. Devido à complexidade das amostras de fertilizantes, estratégias foram adotadas para adequar o método da difenilcarbazida a essa matriz. Além da espectrofotometria de absorção molecular na região do visível, a determinação do teor de Cr(VI) nos extratos foi feita por GF AAS e as concentrações de Cr(VI) estavam abaixo do limite de detecção do método. / The aim of this work was the development of methods for the determination of As, Cd, Cr(III) Cr(VI), Hg, Ni, Pb and Se in mineral fertilizers by graphite furnace atomic absorption spectrometry (GF AAS) and inductively coupled plasma optical emission spectrometry (ICP OES). It was employed a Certified Reference Material (SRM® 695 - Trace elements in multi-nutrient fertilizer) from the National Institute of Standards and Technology (NIST) and an in-lab candidate of Reference Material (MR), mix-micro sample (raw material used in formulation of mineral fertilizers to improve micronutrient content) provided by LANAGRO (Laboratório Nacional Agropecuário, Goiania, Brazil). The analysis of MR sample by X-ray fluorescence (XRF) showed the matrix complexity, mainly due to the presence of high levels of Al, Si, Fe, Ti, Mn and Ca. The ICP OES optimization was carried out aiming rubust conditions for As, Cd, Cr, Ni and Pb determination by direct nebulization solutions, and As, Hg and Se with nebulization combined with vapor generation. It was found that the methods of sample preparation, USEPA 3051 and 3052 (US Environmental Protection Agency), can be applied only for the determination of As, Cd and Pb. Elements that are strongly bound to the matrix, such as Cr and Ni were not quantitatively extracted. Digestion by method USEPA 3052 in the presence of H3BO3 alter the relative error from -36% to -15% for Cr and Ni concentration was also higher in this case. For the simultaneous determination of As, Hg and Se by ICP OES vapor generation (VG-ICP OES), a pre-reduction procedure for Se (VI) was necessary, involving heating at 90 °C of the solutions in HCl 6 mol L-1. The additional step for Se reduction did not impair Hg and As determination. The vapor generation for simultaneous elements determination with the gas-liquid separation occurring within the cyclonic spray chamber. The extraction using bath and ultrasonic probe in the presence of dilute acids (HCl, HNO3, H3PO4) did not influence considerably the determination of As, Cd, Cr, Ni and Pb by ICP OES and Se by GF AAS. Only atmospheric air bubbling was enough for an efficient extraction providing results comparable to ultrasonic devices. The use of small volumes of concentrated acids proved to be suitable for improving extraction efficiency, particularly for Ni. Concentrated HCl was the most suitable condition for extraction. For Cr(VI) determination, various solutions and alkaline extractant was studied, and the use of the thermostatic bath and ultrasound bath was evaluated. Due to the complexity of fertilizer samples, strategies were adopted to adapt diphenylcarbazide method to this matrix. Besides Cr(VI) determination in extracts by molecular absorption spectrophotometry in the visible region, it was also performed by GF AAS and Cr(VI) concentration was below limit of detection of the method.
50

Uma metodologia automatizada por fluxo-batelada para a preparação de microemulsões de gasolina e de nafta para a determinação de íons metálicos por espectrometria de absorção atômica em forno de grafite / An automated methodology for flow-batch for the preparation of microemulsions of gasoline and naphtha for the determination of metals ions by graphite furnace atomic absorption spectrometry

Cunha, Francisco Antonio da Silva 21 March 2011 (has links)
Made available in DSpace on 2015-05-14T13:21:11Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2503826 bytes, checksum: efc2f2118eacd06235948cf7c3c38d1f (MD5) Previous issue date: 2011-03-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work we have developed an automated methodology for the analysis of metals in gasoline and naphtha in the form of microemulsions using a flow-batch analyzer with piston propulsion for the preparation of microemulsions and quantification of analytes by GF AAS. Three studies were conducted, the first concerning the study of optimal composition of microemulsions made through the construction of phase diagrams for gasoline and naphtha. The second study sought to improve all operational parameters of the automatic system for the production of solutions and also in relation to their coupling to the instrument for analysis. Finally it was done to optimize the operating parameters of the GF AAS for the quantification of metals which have been quantized in two ways, the first quantification by a procedure manual preparation of microemulsions and the second by the same automatic preparation. The two results were then compared by paired t test at a 95% level of confidence, no significant differences between the two relevant procedures. Furthermore, recovery tests performed showed acceptable accuracy for the two methods investigated, with average recoveries in the ranges from 88 to 93% for the automatic method and between 86 to 92% without significant differences in both a 95% level of confidence. The characteristic masses obtained were 0.36pg for Cu, 0.29pg for Cr and 0.87pg for Pb, with limits of detection and quantification respectively of 0.073 and 0.22 for Cu, 0.024 and 0.72 for Cr and 0.115 and 0.346 for Pb. / Neste trabalho foi desenvolvida uma metodologia automática para a análise de metais em gasolina e nafta na forma de microemulsões utilizando um analisador em fluxo-batelada com propulsão a pistão para a preparação das soluções e posterior quantificação dos analitos por GF AAS. Três estudos foram realizados, sendo o primeiro referente ao estudo da composição ótima das microemulsões feito através da construção de diagramas de fases para a gasolina e para a nafta. O segundo estudo tratou de aperfeiçoar todos os parâmetros operacionais do sistema automático para a produção das soluções e também em relação ao seu acoplamento ao instrumento de análise. Por fim foi realizado a otimização dos parâmetros operacionais do GF AAS para a quantificação dos metais, que foram quantizados de dois modos, sendo a primeira quantificação através de um procedimento de preparação manual das microemulsões e a segunda pela preparação automática das mesmas. Os dois resultados obtidos foram então comparados através do teste t pareado a um nível de 95% de confiança, sem diferenças estatísticas relevantes entre os dois procedimentos. Além disso, testes de recuperação realizados indicaram precisão satisfatória para as duas metodologias investigadas, com recuperações médias nas faixas de 88 a 93% para o método automático e entre 86 a 92% ambos sem diferenças significativas a um nível de 95% de confiança. As massas características obtidas foram de 0,36pg para Cu, 0,29pg para Cr e 0,87pg para Pb, com limites de detecção e quantificação respectivamente de 0,073 e 0,22 para Cu, 0,024 e 0,72 para Cr e 0,115 e 0,346 para Pb.

Page generated in 0.0221 seconds