• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 248
  • 133
  • 42
  • 36
  • 36
  • 10
  • 10
  • 7
  • 7
  • 5
  • 4
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 648
  • 84
  • 60
  • 59
  • 55
  • 46
  • 40
  • 36
  • 35
  • 33
  • 32
  • 32
  • 32
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

[en] EXTENSION OF THE MISME AND FIMBEL MODEL FOR THE DETERMINATION OF THE CUMULATIVE DISTRIBUTION OF THE RAIN DIFFERENTIAL ATTENUATION BETWEEN TWO CONVERGING LINKS / [pt] EXTENSÃO DO MODELO DE MISME E FIMBEL PARA A DETERMINAÇÃO DA DISTRIBUIÇÃO CUMULATIVA DA ATENUAÇÃO DIFERENCIAL DEVIDA À CHUVA ENTRE DOIS ENLACES CONVERGENTES

HENRIQUE GRYNSZPAN 07 November 2008 (has links)
[pt] Neste trabalho, desenvolveremos um modelo teórico baseado em extensão do modelo de Misme e Fimbel para a determinação da distribuição cumulativa da atenuação diferencial devida à chuva entre dois enlaces convergentes. Resultados do modelo desenvolvido serão comparados com medidas realizadas na cidade de São Paulo e no Japão. Adicionalmente, apresentaremos previsões do modelo para os efeitos das variações do ângulo entre os enlaces, assim como dos seus comprimentos, sobre a distribuição cumulativa da atenuação diferencial. Em seguida, calcularemos a indisponibilidade do enlace desejado sujeito à interferência de outro enlace convergente, indicando que a consideração da atenuação simultânea nos dois enlaces permite um dimensionamento capaz de utilizar o espectro eletromagnético de forma mais eficiente. / [en] In this work, we will develop a theoretical model based on an extension of the Misme and Fimbel model for the determination of the cumulative distribution of the rain differential attenuation between two converging links. Results from the developed model will be compared with measurements performed in the City of São Paulo and in Japan. Additionally, we will present model predictions for the effects of variations in the angle between the links and in the path lengths on the cumulative distribution of the rain differential attenuation. Next, we will determine the unavailability of a link in the presence of interference from another converging link. It will be indicated that consideration of the possibility of simultaneous attenuation on both links leads to a more efficient use of the electromagnetic spectrum.
362

Aplicação de exame de resposta auditiva de estado estável para avaliação da atenuação de protetores auriculares /

Queiroz, James Luizar de. January 2009 (has links)
Orientador: João Candido Fernandes / Banca: Edson Antonio Capello Sousa / Banca: Andrea Cintra Lopes / Resumo: O objetivo desta pesquisa foi determinar os níveis de atenuação de Dispositivos de Proteção Auditivos (DPAs), usando um teste chamado Resposta Auditiva de Estado Estável (RAEE). O teste RAEE é um exame eletrofisiológico que usa elétrodos para captar a atividade elétrica do tronco encefálico, sem depender da resposta do indivíduo, eliminando a subjetividade, assim como aspectos ligados à atenção, tempo de resposta, níveis de audição, etc. Neste método foram avaliados dez indivíduos, por meio da RAEE, estimulando-se o sistema de audição, primeiro sem protetor e, subsequentemente, com dois tipos de protetores auditivos, a saber um de inserção intra-auricular outro circunauricular de uso comum no mercado. Os resultados evidenciaram valores inferiores àqueles expressos no Certificado de Aprovação: para o plug, uma diferença de 10,3 dB, e para a concha, 4,3 dB. Na repetição dos testes, encontrou-se uma boa repetitividade, com diferença entre zero e 5 dB para 75% das frequências testadas. / Abstract: The purpose of this research was to determine the levels of attenuation of Hearing Protection Devices (HPDs) using a test called Auditory Steady-State Response (ASSR). The ASSR test is an electrophysiological examination that uses electrodes to capture the electrical activity of the auditory nerve and the brainstem without depending on the individual's response, thus eliminating the subjectivity of personal factors such as attention, response time, hearing ability, etc. This paper presents the results of a ten test which evaluated the hearing threshold of individuals, by first stimulating the hearing system without a protector and subsequently with a hearing protector. The results of this study were lower than those expressed in the Certificate of Approval: to plug a gap of 10.3 dB and dB the ear mufflers. The repetition of tests found a good repeatability with a difference between zero and 5 dB for 75% of the frequencies tested. / Mestre
363

[en] PLANNING OF OUTDOOR BROADBAND FIXED WIRELESS ACCESS SYSTEMS OPERATING AT 10-66 GHZ BAND / [pt] PLANEJAMENTO DE SISTEMAS FIXOS PARA ACESSO SEM FIO EM FAIXA LARGA OPERANDO EM AMBIENTES ABERTOS EM FREQÜÊNCIAS ENTRE 10 E 66 GHZ

FERNANDO JOSE DE ALMEIDA ANDRADE 25 October 2006 (has links)
[pt] O projeto de sistemas fixos de acesso sem fio em banda larga operando em ambientes abertos em frequências entre 10 e 66 GHz requer um planejamento criterioso devido à necessidade de maximizar a utilização da largura de banda disponível, maximizar a capacidade da rede, garantir requisitos mínimos de disponibilidade e minimizar os custos em um tipo de ambiente e em uma faixa de frequências em que as ondas eletromagnéticas são sujeitas a fenômenos específicos durante a propagação. Este trabalho apresenta os aspectos envolvidos no planejamento de sistemas deste tipo que utilizam topologia ponto-multiponto e atendem à recomendação IEEE 802.16. São apresentados modelos para previsão de cobertura, cálculo da atenuação diferencial por chuvas e previsão da atenuação por chuvas considerando a não-homogeneidade das chuvas em duas dimensões horizontalmente. Os efeitos das interferências no desempenho dos sistemas são analisados em conjunto com alguns exemplos de planejamento das células. Os aspectos importantes para o planejamento da capacidade são descritos e técnicas que permitem maximizar a capacidade são apresentadas. Com o objetivo de organizar todas as informações para ajudar em situações reais uma metodologia de planejamento é proposta incluindo considerações técnicas, mercadológicas e financeiras. / [en] The development of outdoor fixed broadband wireless access (BWA) systems operating at 10-66 GHz frequency requires a carefully planning in order to maximizing the use of the bandwidth, maximizing network capacity, assuring minimum requirements of availability and minimizing costs in an environment and in a frequency band where the propagation of electromagnetic waves are subjected to specific issues. This work presents the aspects related to the development of this kind of system in a point-to- multipoint architecture standardized by the IEEE 802.16 recommendation. Models to predict coverage, estimate differential rain attenuation and predict rain attenuation considering the un-homogeneity of the rain in horizontal plane. The effects of interference in the system performance are discussed with some examples of cell planning. The main aspects of capacity planning are described and techniques to maximize capacity are presented. In order to helping the planners in practical situations the information are organized in a proposal of planning methodology that includes technical, business and marketing issues.
364

Métodos Analíticos e Experimentais para Determinação do Número Atômico Efetivo / Analitic and Experimental Methods for Determination of Effective Atomic Number

Gobo, Michel Stephani da Silva 07 December 2017 (has links)
Um material composto, formado pela mistura de muitos elementos, pode ser convenientemente descrito, a partir da forma com que a radiação interage com ele, como se fosse formado por um elemento ctício com um número atômico efetivo, Zef. Esse parâmetro não é constante com a energia, entretanto, pode ser considerado uma ferramenta útil na caracterização de tecidos biológicos, materiais tecido-equivalentes e dosímetros. Várias formas de determinação do Zef foram propostas na literatura, dentre elas, estão os métodos de atenuação que se baseiam no uso da seção de choque total (obtido a partir do coeciente de atenuação linear mássico (µ/)) e os métodos de espalhamento que se baseiam na razão entre as seções de choque diferenciais Rayleigh e Compton. Neste trabalho, buscou-se estudar métodos de obter Zef de forma experimental e teórica, por dois métodos (atenuação e espalhamento) para completar lacunas existentes na literatura. No método de atenuação, foi utilizado o (µ/) como grandeza de interação que, no conhecimento dos autores, ainda não foi utilizado. Para isso, arranjos experimentais que permitam determinar a densidade, , e o coeciente de atenuação linear, µ, foi construído. O µ (de materiais tecido-equivalentes e tecidos biológicos) foi determinado tanto para energia de 59.54 keV (fonte 241Am) com detector CdTe, quanto para faixa de energia entre 15 e 45 keV (tubo de raios X com alvo de W) com detector SDD. Um novo programa computacional para determinar o número atômico efetivo a partir do µ/ foi implementado e validado. A sensibilidade do método foi estudada de forma a determinar Zef de forma adequada. No método de espalhamento, arranjo experimental para detectar os fótons espalhados Rayleigh e Compton (utilizando fonte de 241Am e detector CdTe) foi construído, otimizado e validado. Um programa computacional para determinação de Zef através da razão Rayleigh/Compton, R/C, foi elaborado e validado . A sensibilidade do método foi estudada e analisada de forma a determinar Zef de maneira adequada. No método de atenuação, o arranjos para determinação do µ/ possibilitaram determiná-lo com diferenças menores que 6% quando comparados com a literatura e incertezas de 3.8% para 59.54 keV e até 7% na faixa de 15 à 45 keV. Também foi vericado que o método é adequado para determinar Zef para energias de até 60 keV, pois a partir deste valor, as incertezas em Zef aumentam (para mais de 10%). No método de espalhamento, o arranjo para determinação da razão Rayleigh/Compton possibilitaram obter medidas de R/C com menos de 10% de diferença com a literatura e incertezas de 7% e foi vericado ainda, que a faixa de momento transferido entre 1 Å1 e 2 Å1 é adequada para determinar Zef (incertezas menores que 3% de incerteza) / A composite material, formed by the mixture of several elements, can be conveniently described by, from the way the radiation interacts with it, as if it were formed by a factitious element with an eective atomic number (Zef). This parameter is not constant with the energy, however, can be considered as an useful tool for characterization of biological tissues, tissue-equivalent materials and dosimeters. Several ways for the determination of Zef were proposed by the literature, among them, are the attenuation methods which are based on the total cross section (derived form the mass attenuation coecient (µ/)) and the scatter methods which are based on the ratio between the Rayleigh and Compton dierential cross sections. In this work, were study ways to obtain Zef experimentally and theoretically by two methods (attenuation and scattering) to ll the gaps in the literature. In the attenuation method µ/ was used as interaction coecient which, in the authors knowledge, it hasnt been used. For this purpose, experimental arrangements to determine the density () and the linear attenuation coecient (µ) were built. The µ (of tissue-equivalent material and biological tissues) were determined both for 59.54 keV (241Am source) with a CdTe detector and for the energy rage between 15 and 45 keV (X ray tube, W target) with a SDD detector. A new computational program for determining Zef through µ/ was implemented and validated. The method sensibility was studied in the way to determine Zef properly. In the scattering method, an experimental arrangement to detect the Rayleigh and Compton scattered photons (with 241Am source and a CdTe detector) was built, optimized and validated. A computational program to determine Zef through Rayleigh to Compton ratio, R/C, was elaborated and validated. The methods sensibility was studied and analyzed to determine Zef properly. In the attenuation method, the arrangements for determining µ/ allowed to determine it with dierences smaller than 6% when compared with the literature and uncertainties of 3.8% for 59.54 keV and up to 7% in the range of 15 to 45 keV. It has also been found that the method is suitable for determining Zef for energies of up to 60 keV, because above that energy, the uncertainties in Zef increases (more than 10%). In the scattering method, the arrangement for determining R/C made it possible to obtain measurements of R/C with less than 10% dierence with the literature and uncertainties of 7% and it was veried that the momentum transfer range between 1 Å1 and 2 Å1 is suitable for determining Zef (uncertainties less than 3 % uncertainty)
365

Comparação da atenuação da radiação solar e dos fatores que determinam o clima de radiação solar subaquática em lagos e reservatórios do Brasil / Comparison of solar radiation attenuation and factors that determine underwater solar radiation climate in lakes and reservoirs of Brazil

Rodrigues, Sonia Luiz 26 March 2003 (has links)
O estudo da penetração da radiação solar no meio aquático foi desenvolvido em quatro partes. Na primeira delas, voltada para a atenuação da radiação solar na coluna d’água, foram discutidos fatores de interferência e suas inter-relações. Neste sentido, foi feita uma comparação da penetração da radiação solar em ecossistemas continentais naturais e artificiais, analisando as diferenças e similaridades. O estudo comparativo da atenuação da radiação solar subaquática em toda extensão de reservatórios constituiu a segunda parte deste trabalho. A comparação foi feita entre reservatórios que apresentam proximidades de localização, mas com diferenças marcantes nos usos e ocupações nas regiões em que os mesmos estão inseridos. Na terceira parte foram apresentados dois recursos de grande utilização na obtenção das respostas imediatas do ambiente aquático, do ponto de vista óptico, diante dos impactos sofridos. O primeiro recurso foi a determinação do espectrograma da radiação solar, indicando a atenuação da radiação solar subaquática na faixa fotossinteticamente ativa (400 nm - 700 nm). O outro recurso foi a obtenção do espectro de absorção da água superficial, que permitiu o estabelecimento do “Índice de Absorção Espectral da Água", I.A.E.A., que facilmente possibilita a detecção de fontes pontuais de poluição e contaminação. Como quarta e última parte foi proposto o desenvolvimento de um aparelho a partir da reconstrução do hidrofotômetro (Modelo Nº 268 WA 310 GM MFG & Instrument Corp. Bronx. N.Y. 10 451), onde foi introduzido e adaptado o detector fotocondutivo (PIN - 250DP) em substituição às fotocélulas anteriormente danificadas. Durante o trabalho de campo, este aparelho foi testado e foi feita a comparação com os obtidos do Quanta-meter LI-COR (LI - 185A) também utilizado neste trabalho. / The study of solar radiation penetration in aquatic environment was developed in four parts. The first one, directed to solar radiation attenuation in the water column, interference factors and their inter-relations were discussed. In this sense, a penetration comparison of the solar radiation in natural and artificial continental ecosystems was carried out, analyzing differences and similarities. The second part of this work consisted of a comparative study of underwater solar radiation in the entire reservoir. The comparison was done between reservoirs that are near to one another, but with marked differences in use and occupation within the regions where they are located. In the third part, two resources of great utilization in obtaining immediate response from the aquatic environment, from an optical point of view of the impacts experienced, were presented. The first resort was the spectrogram determination of solar radiation, which indicated the underwater solar radiation attenuation in the active photosynthetic range (400 nm - 700 nm). The other resort was the superficial water absorption spectrum, which allowed establishing the “Water Spectral Absorption Index", I.A.E.A. that easily makes possible detection of accurate sources of pollution and contamination. The fourth and last part proposed to develop an apparatus from the construction of an underwater hydrophotometer (Model 268 WA 310 GM MFG & Instrument Corp. Bronx N.Y. 10451), where the photoconductor detector was adapted and introduced (PIN - 250DP) substituting the previously damaged photocells. During field work, this apparatus was tested and comparison was performed with data obtained from Quanta-meter LI-COR (LI - 185A), also used in this work.
366

Evaluation des composants organiques d'un sol de cokerie en contexte d'atténuation naturelle / Evolution of coking plant soil components in a natural attenuation context

Biache, Coralie 01 July 2010 (has links)
Les sols de cokerie sont très hétérogènes, composés de matériaux de construction et de diverses phases organiques telles que du coke, du charbon, du goudron de houille et du bitume routier, jouant un rôle majeur sur les propriétés de ces sols. Leur nature et leur état de dégradation vont influencer la mobilité des différents contaminants. Cette thèse porte sur l’étude du vieillissement d’un sol de cokerie et ses conséquences sur le devenir des polluants organiques et métalliques. Elle intègre des études réalisées à différentes échelles permettant de considérer différents degrés de complexité, par l’utilisation (i) de composés purs, de matériaux organiques isolés (charbon, goudron de houille)et de sols et (ii) de dispositifs intégrant progressivement les différents processus intervenant lors de l’atténuation naturelle : expériences d’oxydation et de biodégradation en laboratoire, dispositif simplifié permettant de suivre l’évolution naturelle de quelques grammes d’échantillon, parcelles lysimétriques du GISFI permettant un suivi à l’échelle du terrain. Deux schémas de dégradation ont été identifiés au cours des expériences en laboratoire : (i) l’oxydation conduit à un phénomène de condensation qui suggère une stabilisation du compartiment organique ; (ii) la biodégradation induit la formation de plus petites unités moléculaires et la libération de composés organiques présents dans la fraction organique insoluble. Si des tendances sont identifiées au cours des expériences d’atténuation naturelle, elles suggèrent plutôt que le processus majeur impliqué est la biodégradation. La sorption du cuivre est variable selon les constituants organiques considérés, et augmente significativement après les expériences d’altération / Coking plant soils are highly heterogeneous and are made of building materials and various organic constituents such as coke, coal, coal –tar and road asphalt. Those materials can strongly influence soil properties. Thus, the retention of the various contaminants will depend on the nature and the degradation of the soil organic constituents. This work deals with the ageing of a coking plant soil and its consequences on the fate of both organic and metallic pollutants. The multi-scale approach applied in this study allows to consider the different levels of complexity through the use of (i) pure compounds, isolated organic fraction of soils such as coal tar and coal and a soil with its mineral fraction, and (ii) experimental devices gradually integrating the processes involved in natural attenuation : laboratory oxidation and biodegradation experiments, simplified device allowing the study of few grams of samples exposed to natural attenuation, and the GISFI (French Scientific Interest Group – Industrial Wasteland) lysimeter plots allowing the study at field scale). Two major evolutions were evidenced: (i) the oxidation led to a condensation suggesting a stabilization process of the organic compartment; (ii) the biodegradation induce the formation of smaller molecular units and the release of organic compounds from the non extractable part of the organic matter. The trends identified during the natural attenuation experiments suggest that the biodegradation is the major process involved in our ageing experiments. The sorption of copper varied according to the different organic constituents that were tested but was clearly enhanced by the degradation of these constituents
367

Avaliação da tensão superficial, parâmetros reológicos e atenuação acústica de suspensões de açaí / Analysis of surface tension, ultrasound attenuation and rheological parameters of açai\' suspensions

Trevisan, Bruno Peruchi 14 October 2011 (has links)
Nesta pesquisa teve-se como objetivo estudar as propriedades físicas de polpas de açaí disponíveis comercialmente, tais como: pH, condutividade, viscosidade, tensão superficial e atenuação acústica, em função da temperatura e de particulados presentes na suspensão de açaí. Foram selecionadas quatro marcas comerciais de polpa de açaí originárias da região norte do Brasil. As amostras foram estudadas na forma pura (sem diluição) e diluídas. As análises de tensão superficial foram conduzidas utilizando o tensiômetro da Sensadyne (modelo QC6000) na faixa de temperatura de 15ºC a 60ºC. Observou-se uma variação da tensão superficial entre as marcas estudadas e em todos os casos a polpa de açaí diluída apresentou tensão superficial superior à polpa pura. Para valores de temperatura maiores que 45ºC, a tensão superficial aumentou com a temperatura para duas marcas estudadas. A verificação da atenuação e do tamanho de partículas foi realizada utilizando a técnica de espectroscopia de atenuação acústica com o equipamento APS-100 (Matec Applied Science, Northborough, USA). A polpa diluída apresentou uma menor atenuação com relação à polpa pura. As polpas de açaí, pura e diluída, apresentaram partículas com tamanho inferior a 0,6 µm de diâmetro, sendo que a polpa pura apresentou partículas com diâmetros maiores. Na investigação reológica foram utilizados reômetros rotacionais (Modelo DVIII+) da marca Brookfield com geometrias de cone-placa e cilindros concêntricos na faixa de temperatura de 15ºC a 60ºC. Os reogramas obtidos foram ajustados aos modelos de Ostwald-de-Waale (Lei da Potência) e Herschel-Bulkley, sendo que o melhor ajuste foi obtido com o modelo de Lei da Potência. Todas as amostras estudadas apresentaram comportamento reológico não-Newtoniano, com características de fluidos tixotrópicos. Foi investigado também o comportamento reológico de polpas de açaí tratadas enzimaticamente para posterior processamento por microfiltração tangencial. As enzimas comerciais Pectinex Ultra SP-L, Biopectinase KK Plus e Ultrazym AFPL foram avaliadas separadamente e a respectiva eficiência foi analisada pela redução da viscosidade no reômetro rotacional com a geometria de cone-plana. A enzima comercial Ultrazym foi mais eficiente na redução da viscosidade aparente da polpa de açaí, sendo que as enzimas Pectinex e Biopectinase não apresentaram alteração significativa da viscosidade. A análise da viscosidade aparente dos produtos (permeado e retentado) da microfiltração utilizando membranas cerâmicas comerciais de 0,8 e 0,2 \'mü\'m foi feita utilizando o reômetro rotacional com a geometria de cone-placa, na temperatura de 25ºC. Para o processamento por microfiltração sem tratamento enzimático, o retentado apresentou valores de viscosidade aparente superior ao permeado e à polpa diluída, enquanto que a polpa diluída apresentou viscosidade aparente superior ao permeado. Na microfiltração com tratamento enzimático a polpa diluída apresentou viscosidade aparente inferior ao permeado, comportamento observado para as duas membranas estudadas (0,8 e 0,2 \'mü\'m). Com os resultados obtidos foi possível verificar a grande variação nas propriedades físicas de polpas comerciais de açaí e com isso, a importância de se realizar tais medidas para a otimização de processos como a microfiltração tangencial. / The main objective of this research was the study of physical properties of commercial types of açaí pulp; including pH, electric conductivity, viscosity, surface tension and acoustic attenuation as a function of temperature and particulates of açaí suspension. Four types of açaí pulp from north region of Brazil were selected. The samples were analyzed in pure (undiluted) and diluted form. Surface tension was measured with Sensadyne tensiometer (model QC6000) in the temperature range: 15º to 60º Celsius. In all types of pulp studied the surface tension of diluted sample was higher than pure sample. For temperatures above 45º Celsius surface tension increased for two types of açai pulp studied. Acoustic attenuation and particle size of samples were analyzed with the equipment APS-100 from Matec Applied Science, Northborough, USA. Acoustic attenuation of diluted samples is smaller for pure samples; the açaí pulp (pure and diluted) has particle sizes below 0,6 µm and the particle sizes of the pure samples were larger than the diluted samples. Brookfield/USA rotational rheometers (Model DVIII+) was employed for rheological analysis with two geometries: cone-plate and concentric cylinders in the temperature range: 15º to 60º Celsius. The rheological behavior was adjusted by Ostwald-de-Waale model (or Power-law model) and Herschel-Bulkley model; the Ostwald-de-Waale model showed a better fit. All brands of pulp studied presented non-Newtonian behavior with tixotropic characteristics. It also investigated the rheological behavior of açaí pulp treated enzymatically for later processing by tangential microfiltration. The commercial enzymes: Pectinex Ultra SP-L (Novozymes - Bagsvaerd, Dinamarca), Biopectinase KK Plus (Kerry Bio-Science) and Ultrazym AFPL (Novozymes - Bagsvaerd, Dinamarca), were utilized to reduce viscosity and the effect was evaluated with the cone-plate geometry of the Brookfield/USA rheometer (Model DVIII+). The data shows that the Ultrazym enzyme was the best option for viscosity reduction of açaí pulp, and the other presented no changes in the viscosity. The viscosity of the retentate and permeate from the microfiltration process (membranes with cut-off 0,8 and 0,2 µm) was determined with the cone-plate geometry of the Brookfield/USA rheometer (Model DVIII+) at 25º Celsius. In microfiltration process without enzymatic action, the apparent viscosity of retentate was always higher than the retentate from diluted pulp. With the results we observed the large variation in physical properties of commercial açaí pulp and thus, the importance of carrying out such measures for the optimization of processes such as tangential microfiltration.
368

Aplicação da análise do sinal do GPR na definição de ambientes costeiros

Leandro, Carolina Gonçalves January 2018 (has links)
Na barreira regressiva da Pinheira, são reconhecidos quatro ambientes deposicionais costeiros, caracterizados por parâmetros geológicos como a análise de litofácies, estruturas sedimentares, grau de compactação e conteúdo de moluscos. Informações que são analisadas em conjunto com imagens de dados geofísicos obtidas com o método do Radar de Penetração no Solo (GPR – Ground Penetrating Radar) para determinar esses ambientes. O presente trabalho visa a caracterização destes ambientes deposicionais através da análise da amplitude do sinal em traços de antenas com frequências centrais de 80, 100, 200 e 400 MHz em conjunto com os dados de compactação e litológicos de um furo de sondagem. E também mostra o comportamento da atenuação do sinal em relação a umidade presente no ambiente. A análise dos traços permitiu a identificação dos contatos entre os ambientes já descritos para barreiras regressivas, mostrando variação no valor das amplitudes (decréscimo ou aumento) em conjunto com a variação no grau de compactação, que evidenciam em subsuperfície a mudança entre os ambientes de cordões litorâneos, backshore/foreshore e shoreface superior e inferior. A interferência da umidade na atenuação do sinal nos dados analisados pode ser observada apenas nos primeiros 0,5 m. Demonstrando que a pluviosidade não é um fator de relevância para atenuação do sinal em ambientes arenosos onde o nível da água é próximo a superfície. A análise dos radargramas para todas as antenas, permitiu a identificação dos padrões de refletores já descritos para os ambientes da área de estudo e a antena com frequência central de 200 MHz apresentou maior resolução para a definição de todos os ambientes. / In the Pinheira regressive barrier, four coastal depositional environments are recognized, characterized by geological parameters such as lithofacies analysis, sedimentary structures, compaction degree and set of mollusks. Information that is analyzed together with images of geophysical data obtained with the Ground Penetrating Radar (GPR) method to determine these environments. The present work aims to characterize these depositional environments by analyzing the signal amplitude in traces with central frequencies antennas of 80, 100, 200 and 400 MHz in conjunction with the compaction and lithological data of a drill hole. It also shows the behavior of signal attenuation in relation to the humidity present in the environment. The analysis of the traces allowed the identification of the contacts between the environments already described for regressive barriers, showing variation in the value of the amplitudes (decrease or increase), together with the variation in the degree of compaction, which evidences in subsurface the change between the environments of foredune ridges, backshore/foreshore and upper and lower shoreface. The interference of humidity in attenuation of the signal in the studied data can be observed only in the first 0.5 m. Rainfall was not relevant for signal attenuation in the studied sandy deposits with water level close to the surface. The analysis of the radargrams for all the antennas allowed the identification of the patterns of reflectors already described for the environments of the study area and the central frequency antenna of 200 MHz showed the highest resolution for the definition of all the environments.
369

Imagerie tri-dimensionnelle de l'atténuation sismique du manteau terrestre / 3-D Mapping of the Seismic Attenuation in the Upper Mantle

Adenis, Alice 06 July 2017 (has links)
L'objectif de cette thèse est de construire un modèle d'atténuation sismique du manteau supérieur dela Terre en utilisant un jeu de données original construit par Debayle et Ricard (2012). Ce jeu dedonnées est l'un des plus complet au monde (plus de 375 000 sismogrammes analysés pour extrairel'atténuation et la vitesse de phase du mode fondamental et des cinq premiers harmoniques des ondesde Rayleigh).Les mesures d'atténuation sont tout d'abord traitées pour extraire les effets de l'expansion géométriqueet de la focalisation, minimiser les effets d'erreurs sur la source, écarter les mesures incertaines etregrouper les mesures redondantes. Elles sont ensuite régionalisées pour obtenir des cartes desvariations latérales de l'atténuation des ondes de Rayleigh pour chaque mode et chaque période. Ladernière étape est l'inversion en profondeur des cartes. Elle permet d'obtenir QsADR17, un modèle 3Dde l'atténuation des ondes S dans le manteau supérieur.QsADR17 est corrélé avec la tectonique de surface jusqu'à 200 km de profondeur, avec une faibleatténuation sous les continents et une forte atténuation sous les océans. Des anomalies de forteatténuation sont observées jusqu'à 150~km de profondeur sous les rides océaniques, et persistent à plusgrande profondeur jusque dans la zone de transition sous la plupart des points chauds. La présence delarges anomalies atténuantes situées à 150 km de profondeur sous l'océan Pacifique suggère queplusieurs panaches thermiques viennent s'étaler dans l'asthénosphère. Nous avons également détecté laprésence d'hétérogénéités de composition à la base des cratons et dans un certain nombre de régionsactives. / The aim of this study is to build a 3-D attenuation model of Earth's upper-mantle using a unique datasetbuilt by Debayle & Ricard (2012). This dataset is among the largest in the world: more than 375,000seismograms were analyzed to extract Rayleigh-wave attenuation and velocity measurements for thefondamental mode and the five first harmonics between 40 and 240 s periods.First, attenuation measurements are processed to extract the effects of geometrical attenuation and offocusing and defocusing, in order to minimize the influence of errors on the seismic source, to avoidpotentially incorrect data, and to cluster redondant measurements. Then, measurements are regionalizedto obtain Rayleigh-wave maps for each mode and each period. The last step is the inversion of thesemaps to obtain the depth dependent attenuation. Eventually, we obtain QsADR17, a 3-D model of Swaveattenuation in the upper mantle.QsADR17 is correlated with surface tectonics down to 200 km depth, with low attenuation under thecontinents and high attenuation under the oceans. High-attenuation anomalies are found under oceanicridges down to 150~km depth, and under most of the hotspots at larger depth down to the transitionzone. A large high-attenuation anomaly at 150~km depth under the Pacific ocean suggest that thermalplumes pound into the asthenosphere. We also detect compositional heterogeneities at the base of thecratons and in active areas.
370

Atténuation et dispersion des ondes P en milieu poreux partiellement saturé : approche expérimentale / Attenuation and dispersion of P-wave in partially saturated porous medium : an experimental approach

Barrière, Julien 16 December 2011 (has links)
Afin d'analyser le rôle de la saturation partielle sur la vitesse de phase et l'atténuation des ondes P directes, nous avons élaboré une expérience en laboratoire dans la gamme du kiloHertz. Celle-ci permet une corrélation avec les mesures de terrain et limite les effets d'échelle induits par l'utilisation des traditionnelles mesures ultrasoniques. Le montage expérimental est composé d'un container rempli de sable, équipé d'accéléromètres et de sondes de teneur en eau. Une propagation d'onde est générée par une source mécanique constituée d'une bille en métal frappant une plaque de granite. Plusieurs cycles d'imbibition/drainage sont réalisés entre les saturations résiduelles en eau et en air. Une transformée continue en ondelette a été choisie pour le traitement des données sismiques et validée numériquement par une simulation de propagation d'ondes dans un milieu viscoélastique 2D (code Specfem2D). En imbibition et en drainage, la vitesse de phase décroît avec l'augmentation de la saturation, ce qui peut être expliqué par la limite Biot-Gassmann-Wood (BGW) de la théorie de Biot. Ce comportement, typique des mesures de terrain, indique qu'il est possible de considérer le mélange de fluides (eau et air) comme un fluide effectif. L'interprétation de l'atténuation est plus complexe et ne peut être expliquée par le mécanisme de relaxation de flux macroscopique de la théorie de Biot. Il est nécessaire d'introduire une contribution viscoélastique reliée aux pertes frictionelles grain-à-grain et décrite par un modèle à Q constant. De plus, un hystérésis entre imbibition et drainage est observé et expliqué en introduisant une perméabilité effective du mélange, dépendante des perméabilités relatives à l'eau et à l'air. / In order to analyse the role of partial saturation on direct P-waves phase velocity and attenuation, we performed a laboratory experiment in the kiloHertz range to avoid scale effects between field studies and traditional ultrasonic laboratory measurements. This experiment consists in a sand-filled tank equiped with accelerometers and water capacitance probes, were seismic propagation is generated by hitting a steel ball on a granite plate. Several imbibition/drainage cycles were performed between the water and gas residual saturations. Seismic data were processed by a Continuous Wavelet Transform using the complex Morlet wavelet which was numerically validated using a viscoelastic 2D code for wave propagation (Specfem2D). Phase velocity of direct P-wave decreases with the increase of water content, which is quite consistent with Biot-Gassmann-Wood (BGW) limit of the Biot's theory for both imbibition and drainage. This behaviour indicates that the fluid mixture (gaz and water) can be considered as an effective fluid, which is typical of field seismic applications. In this experiment, attenuation is very strong and cannot be fully explained by the macroscopic fluid flow of Biot's theory. It is necessary to introduce a viscoelastic contribution linked to the grain to grain overall losses, which are described by a constant Q-model. Moreover, hysteresis between imbibition and drainage are observed and explained by introducing an effective permeability of the mixture depending on water and gas relative permeabilities.

Page generated in 0.0336 seconds