• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 301
  • 56
  • 10
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 425
  • 425
  • 230
  • 136
  • 95
  • 94
  • 92
  • 84
  • 78
  • 75
  • 71
  • 71
  • 71
  • 62
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Use of a Synthetic Substrate for Orthodontic Bond Strength Testing

Saikaly, Elijah B. 01 January 2006 (has links)
In vitro bond strength studies are of great importance and interest since they allow the prediction of clinical success of orthodontic adhesives. There are many studies that have investigated bond strength values of bonding systems. However, due to the variation in the materials and methods employed, it is very difficult and often impossible to make comparisons among data. The use of a substrate as an alternate to enamel for mechanical tests would minimize these variables and reduce the challenges faced with in vitro bond strength tests. The purpose of this study was to investigate the suitability of Macor as a substrate for bond strength testing of orthodontic adhesives. Macor samples were custom prepared in a shape similar to that of a human maxillary premolar. The groups tested were: Group 1: acid-etched with 9.6% hydrofluoric acid (HFA) for 60 seconds; Group 2: acid-etched with 9.6% HFA for 90 seconds; Group 3: acid-etched with 9.6% HFA for 120 seconds; Group 4: surface roughened with silicon carbide (Sic); and control group: human premolars etched with 37% phosphoric acid. Following surface preparation, samples were primed and brackets were bonded using Transbond XT (3MlUnitek). Mounted samples were stored in water for 24 hours at 37OC until mechanical testing. Brackets were debonded in the shear mode using an Instron Universal Testing Machine and the force at debond was recorded. The nature of adhesive bond failure among the groups was also compared using an adhesive remnant index (ARI). One-way ANOVA and Weibull analysis statistical tests were used to evaluate and compare the groups. Sample surfaces were analyzed under the light microscope to determine the mode of bond failure for ARI. The Kruskall-Wallis test was used to determine differences in the ARI scores. There were statistically significant differences in shear bond strengths among the enamel and Macor groups (p 0.05). The shear bond strength values of the Macor groups were significantly lower than those of the enamel control group, (p < 0.05). ARI scores were significantly different between the groups (p 10.0001); Macor samples treated with hydrofluoric acid had more adhesive remaining on their surfaces than those in the control and Sic groups. Based on the results of this study, Macor may not be a suitable substrate for bond strength testing in orthodontics.
62

Influência da geometria da ponta ativa de carga na resistência de união de contenção intrarradicular à parede dentinária em canais radiculares achatados de raízes distais de molares inferiores / Influence of the load tip geometry on the bond strength of the intraradicular core to dentin walls in distal flattened root canals of mandibular molars

Plotegher, Fernanda 04 July 2018 (has links)
O objetivo deste estudo foi avaliar a influência da ponta ativa de carga circular e achatada na resistência de união (RU) da contenção intrarradicular à parede dentinária de canais radiculares achatados, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (CT), bem como avaliar os padrões de falhas em estereomicroscópio (EM) e microscopia confocal a laser (MCL) e a distribuição de tensão pelo método de elementos finitos. Raízes distais de molares inferiores com secção transversal achatada foram preparadas endodonticamente e armazenadas em 100% de umidade à 37°C por 7 dias. Após este período, as raízes foram submetidas ao preparo do espaço para o PFV Exacto #1 no comprimento de 8,0 mm, correspondente à dois terços do comprimento total da raiz, com brocas Largo #1,0, e complementadas com Brocas Exacto #1. O tratamento da superfície do PFV foi realizada de acordo com a recomendação do fabricante. O PFV foi cimentado com RelyX U200, por meio da seringa Centrix®. As raízes foram armazenadas em 100% de umidade à 37° C durante 7 dias. Para a execução do teste push-out foram confeccionadas pontas ativa de carga com secções transversais achatada e circular. A determinação da secção das pontas foi realizada a partir da proporção de 85% das médias do diâmetro maior e menor de raízes preparadas e restauradas com PFV, obtidos por meio de imagens em CT . Foram fabricadas pontas achatadas de aço inoxidável por meio de micro usinagem e eletroerosão a fio, com 4 secções diferentes, sendo: A-2,89 mm x 1,96 mm; B-2,05 mm x 1,50 mm; C-1,50 mm x 0,84 mm e D-1,20 mm x 0,64 mm. Para a confecção das pontas circulares, a mesma proporção foi calculada, e foram fabricadas de aço inoxidável por meio de usinagem, com 4 diâmetros diferentes, sendo: a-1,2 mm; b-0,90 mm; c-0,70 mm e d-0,50 mm. Para o correto alinhamento das amostras, foram fabricadas dispositivos de poliuretano com orifício central de 2,5 mm; 1,5 mm e 1,0 mm de diâmetro. As raízes foram seccionadas para obtenção de dois slices (1 mm ± 0,2) dos terços cervical e médio (n=64). Um slice de cada terço de um mesmo espécime foi submetido ao teste de push-out com pontas ativas de carga circular (n=32) e achatada (n=32), por meio de dispositivo mecânico MTS acoplado ao CT SkyScan 1174 (50kV, 80mA). Os tipos de falhas foram avaliados por EM e MCL. Para gerar modelo 3D de elementos finitos 2 elementos aleatórios foram escaneados em CT 1146 com 90 kv e 237 mA (filtro de Cu de 0.1 mm) com resolução isotrópica de 9 m e rotação de 360°, para obter imagens do terço cervical e médio, do mesmo elemento. Os dados foram analisados por testes estatísticos paramétricos (p>0,05). Para avaliar a influência do fator tipo de ponta ativa de carga e terço radicular foi utilizado o teste ANOVA. O teste qui-quadrado foi utilizado para avaliar o tipo de falha ocorrida após o teste de RU. As pontas ativas de carga circular (4,39 ± 1,52 Mpa) apresentaram maiores valores de RU (p=0,015) em relação as pontas achatadas (3,60 ± 1,10 Mpa). A análise dos terços radiculares (p=0,032) apresentou maior RU no terço médio (4,34 ± 1,62 Mpa) comparado ao terço cervical (3,65 ± 0,99 Mpa). A interação tipo de ponta de carga ativa x terço não houve diferença estatística (p=0,058). Na análise do padrão de falha em relação ao tipo de ponta (p=0,005), o teste qui-quadrado apresentou maior percentual de falha adesiva à dentina nas pontas achatadas, e nas pontas circulares maior ocorrência de falhas mistas (p=0,005). Na interação terços x padrão de falha, o terço cervical apresentou maior percentual de falhas mistas em relação ao terço médio (p=0,003). E o terço médio apresentou maior percentual de falhas mistas adesivas (p=0,003). No modelo 3D dos slices testados com as pontas achatadas, a interface de união mostrou maior concentração de tensões von misses. Enquanto que as pontas circulares apresentaram concentração de tensão na interface da ponta ativa e o cimento resinoso. Análise de Tensão Máxima confirmou maior quantidade de tensões na interface adesiva dos slices testados com a ponta achatada. Conclui-se que a ponta achatada apresentou melhor comportamento ao apresentarem menores valores de resistência de união da interface adesiva do pino de fibra de vidro e cimento resinoso à parede dentinária de canais distais achatados em molares inferiores / The objective of this study was to evaluate the influence of circular and flattened load active tips on the bond strength (BS) of intraradicular core to dentin walls of flattened root canals of mandibular molars, using the material testing stage (MTS) coupled to a micro-computed tomography (CT) scanner, as well as to analyze the failure patterns using stereomicroscopy (SM) and confocal laser microscopy (CLM) and the stress distribution by the finite element method. Distal flattened root canals of mandibular molars were prepared endodontically and stored in 100% humidity at 37 °C for 7 days. After this period, the post space was prepared with a #1.0 Largo bur and complemented with #1 Exact drills to receive a #1 Exact glass fiber post (GFP) at 8.0 mm length, corresponding to two thirds of the total root length. The GFP surface was treated according to the manufacturer\'s recommendation and the GFP was cemented with RelyX U200, applied with the syringe Centrix®. The roots were stored in 100% humidity at 37 ºC for 7 days. For the push out test, load active tips with flat and circular cross section were provided at 85% ratio of the largest and smallest diameter of the roots prepared and restored with GFP, using CT images. The flattened load tips were fabricated by micromachining and electrical discharging machine, with 4 different cross sections: A-2.89 mm x 1.96 mm; B-2.05 mm x 1.50 mm; C-1.50 mm x 0.84 mm and D-1.20 mm x 0.64 mm. To fabricate the circular load tips, the same proportion was calculated, and were made by machining, with 4 different diameters, being: a-1.2 mm; b-0.90 mm; c-0.70 mm and d-0.50 mm. For the correct alignment of the samples, were manufactured polyurethane devices with central orifice of 2.5 mm; 1.5 mm and 1.0 mm diameter. The roots were sectioned to obtain two slices (1 mm ± 0,2) of cervical and middle thirds (n = 64). One slice of each third of the same specimen was submitted to a push-out test with active circular (32) and flattened (32) load tips, by MTS mechanical device coupled to CT SkyScan 1174 (50kV, 80mA). The failures modes were analyzed by SM and CLM. To create 3D finite element model, 2 random elements were scanned with 1146 CT scan with 90 kV and 237 mA (0.1 mm Cu filter) with 9 m isotropic resolution and 360° rotation to obtain images of cervical and middle root canal thirds of the same tooth. Data were analyzed by parametric statistical tests (p>0.05). The ANOVA test was used to evaluate the influence of the load active tip and root third. The chisquare test was used to evaluate the failure modes occurred after the BS test. The circular load active tips (4.39 ± 1.52 MPa) showed higher BS values (p = 0.015) than the flattened tips (3.60 ± 1.10 MPa). Analysis of the root thirds (p = 0.032) presented higher BS of middle third (4.34 ± 1.62 Mpa) than the cervical third (3.65 ± 0.99 Mpa). The load active tip and root canal third interaction was not statistically significant (p = 0.058). The chi-square test showed (p = 0.005) higher percentage of adhesive failure in the flattened load tip, while the circular load tip showed a higher percentage of mixed failures (p = 0.005). In the root canal third x failure interaction, the cervical third presented higher percentage of mixed failures than middle third (p = 0.003) and the middle third showed higher percentage of adhesive failures (p = 0.003). The 3D model showed higher concentration of von misses stress at the adhesive interface of slices tested with flattened tips, while the circular tips showed stress concentration at interface between active load tip and resin cement. Maximum Voltage analysis confirmed the occurrence of more stresses at the adhesive interface of the slices tested with the flattened load tip. It may be concluded that the flattened load active tip had a better performance with lower bond strength at the adhesive interface between the GFP and resin cement to dentin wall distal flat oval root canals of mandibular molars
63

Avaliação da influência do tratamento superficial e do condicionador sobre a resistência ao cisalhamento da união entre uma liga de Co-Cr-Mo e reparos em resina composta

Freitas, Anderson Pinheiro de 04 July 2005 (has links)
Para avaliar o efeito de diferentes tratamentos superficiais sobre a resistência ao cisalhamento da união entre uma liga metálica (Co-Cr-Mo - Remanium CD) e uma resina composta (Z-250) e analisar o tipo de fratura durante a separação dos espécimes, sessenta discos metálicos foram fundidos, regularizados e polidos, submetidos a quatro ciclos térmicos (vácuo, 960ºC, 8 minutos) e divididos aleatoriamente em seis grupos. Cada grupo recebeu um tipo de tratamento: Grupo ASB: Asperização com ponta diamantada (No 3118); Grupo ASI: Asperização e aplicação do silano (3M); Grupo AAP: Asperização e aplicação do Alloy Primer (Kuraray); Grupo JSB: Jateamento com óxido de alumínio (50µm, 75lib/pol2); Grupo JSI: Jateamento e aplicação do silano; Grupo JAP: Jateamento e aplicação do Alloy Primer. Todos os espécimes receberam aplicação do adesivo Single Bond e da resina Z-250 (3M), foram armazenados em água deionizada a 37ºC por 24 horas e separados em ensaio de cisalhamento. Os resultados e desvio-padrão de cada grupo, expressos em MPa foram: ASB: 12,708±2,962; ASI: 16,343±2,714 e AAP: 16,723±2,666; JSB: 25,958±5,650; JSI: 28,185±3,322; JAP: 28,670±3,246. Os maiores valores foram produzidos pelos grupos jateados (JSB, JSI e JAP); o silano e o Alloy primer aumentaram a retentividade entre a resina Z-250 e a liga de Co-Cr-Mo, independente da textura superficial e sem apresentar diferença entre os mesmos; todos os espécimes apresentaram falha adesiva na interface testada. / To evaluate the effect of different surface treatments on shear bond strength between a metallic alloy (Co-Cr-Mo - Remanium CD) and a composite resin (Z-250) and to evaluate the fracture mode after testing, sixty disks were casted, polished, submitted to four thermal cycles (960ºC/8min) and divided randomly in six groups. Each group received a different type of treatment: Group ASB: roughen with diamond bur (No 3118); Group ASI: roughen and application of a ceramic Primer; Group AAP: roughen and application of a metallic Primer; Group JSB: Sandblasting with 50 µm aluminum oxide (75lib/pol2); Group JSI: Sandblasting and application of a ceramic Primer; Group JAP: Sandblasting and application of a metallic Primer. All the specimens received the application of an adhesive (Single Bond) and a composite resin (Z-250 /3M). The groups were stored in distilled water at 37ºC during 24 hours and submitted to shear bond strength test. The results and the standard deviation of each group (expressed in MPa) were: JSB: 25,958±5,650; JSI: 28,185±3,322; JAP: 28,670±3,246; ASB: 12,708±2,962; ASI: 16,343±2,714 and AAP: 16,723±2,666. The highest values were obtained by the sandblasted groups (JSB, JSI e JAP). In spite of the surface, ceramic primer and alloy primer increased the retention between the composite resin Z-250 and the Co-Cr-Mo alloy without statistical differences on the results; all of the specimens showed adhesive failures.
64

Ação triboquímica do ciclo mastigatório na resistência ao cisalhamento de resinas compostas / Tribocorrosion effects of masticatory cycle on the composite resins shear bond strength

Contente, Marta Maria Martins Giamatei 07 October 2013 (has links)
Este trabalho avaliou in vitro a ação de estímulos triboquímicos que simulam o ciclo mastigatório na resistência ao cisalhamento de duas resinas compostas Filtek P90®- 3M ESPE (P) e Z250®-3M ESPE (Z) com e sem presença de contaminação salivar, assim como a liberação de íons e a qualidade e a quantidade do desgaste produzido. A amostra foi composta por 12 grupos experimentais (n=5): P1 e Z1, sem contaminação/contra dente decíduo; P2 e Z2, com contaminação/contra dente decíduo; P3 e Z3, sem contaminação/contra dente permanente; P4 e Z4, com contaminação/contra dente permanente; P5 e Z5 sem contaminação (controle); P6 e Z6 com contaminação (controle). Ensaios de tribocorrosão foram efetuados na configuração pino-placa de deslizamento linear alternativo, na presença da solução de saliva artificial, carga de 3N e frequência de 1Hz, totalizando 900 ciclos de desgaste durante 15 minutos. As pistas de desgaste foram caracterizadas por MEV, EDX e XRD e o volume de desgaste por análise da variação de massa. A MEV demonstrou que os grupos Z apresentaram maior quantidade de desgaste quando comparados aos grupos P e que os antagonistas de dente permanente apresentaram maior quantidade de resíduos do material desgastado que os antagonistas em dentes decíduos. A análise por XRD não apresentou variação na caracterização de nenhuma das amostras quando se comparou os espécimes antes e após a realização dos experimentos. Na análise por EDX observou-se picos correspondentes aos elementos Ítrio e Silício para os antagonistas dos grupos P e de Zircônia para os dos grupos Z. Os dados obtidos pelo ensaio de nanoendentação não apresentaram diferença estatisticamente significante para nenhum dos grupos estudados (ANOVA e Teste de Duncan p&le;0,05). Nenhuma diferença estatisticamente significante foi encontrada pelos corpos de prova em resina composta ou antagonistas em nenhum dos grupos estudados quando da análise da variação de massa. Os valores de resistência ao cisalhamento foram: P1 11,20 (±1,44); P2 9,28 (±1,88); P3 8,94 (±1,03); P4 5,76 (±1,47); P5 17,50 (±3,28); P6 15,31 (±1,19); Z1 12,17 (±1,56); Z2 9,60 (±1,56); Z3 10,79 (±3,33); Z4 9,14 (±2,06); Z5 9,77 (±2,27) e Z6 9,22 (±1,98). Os valores de resistência ao cisalhamento foram menores para os grupos P submetidos à contaminação salivar. Na análise de ICP-MS maior liberação de íons Cálcio foi constatada em todos os grupos. A liberação de íons Fosfato foi observada na solução resultante do ensaio tribológico do corpo de prova em resina composta P90 contra antagonista dente permanente. Conclui-se que não há alterações químicas na superfície das resinas após o ensaio mecânico de desgaste e a resina composta P90 apresentou os menores valores de resistência ao cisalhamento em comparação com a resina Z250. A contaminação salivar interferiu negativamente nos valores de resistência ao cisalhamento quando a resina composta P90 foi avaliada. Dente utilizado como contra corpo não teve sua superfície alterada pela incorporação de resíduos de desgaste da resina composta, mantendo o módulo de elasticidade e a nanodureza, sendo que o desgaste ocorreu de forma mais acentuada nas restaurações de resina composta Z250. A liberação de íons Cálcio foi maior que a de íons Fosfato em todas as situações analisadas e a liberação de íons Fosfato foi maior na situação em que o corpo de prova em resina composta P90 foi submetido ao ensaio tribológico contra antagonista dente permanente. O ciclo mastigatório interferiu na resistência ao cisalhamento da resina composta P90. / This study evaluated in vitro the action of tribochemical stimuli simulating the masticatory cycle on the shear bond strength of two composite resins Filtek P90®- 3M ESPE (P) and Z250®-3M ESPE (Z) - with and without salivary contamination, as well as the release of ions and the quality and amount of composite resin/tooth wear. Twelve experimental groups (n=5) were formed: P1 and Z1, without contamination/against primary tooth; P2 and Z2, with contamination/against primary tooth; P3 and Z3, without contamination/against permanent tooth; P4 and Z4, with contamination/against permanent tooth; P5 and Z5, without contamination (control); P6 and Z6, with contamination (control). Tribocorrosion assays were performed using the pin-on-plate configuration under linear reciprocating sliding, in the presence of an artificial saliva solution and under 3 N load and 1 Hz frequency, totalizing 900 wear cycles during 15 minutes. The wear was characterized by SEM, EDX and XRD analyses and the wear volume was determined by mass variation analysis. The SEM analysis showed that the Z groups presented less wear than the P groups, and that the permanent tooth antagonists presented more worn material residues than the primary tooth antagonists. The XRD analysis did not reveal variation in the characterization of any of the samples, comparing the specimens before and after the experiments. The EDX analysis revealed peaks corresponding to the elements yttrium and silicon for the P groups\' antagonists and zircon for the Z groups\' antagonists. Data from the nanoindentation test did not show statistically significant difference for any of the groups (ANOVA and Duncan test p&le;0.05). For the mass variation analysis, no statistically significant difference was found between the composite resin specimens or antagonists in any of the groups. The shear bond strength results were: P1 11.20 (±1.44); P2 9.28 (±1.88); P3 8.94 (±1.03); P4 5.76 (±1.47); P5 17.50 (±3,28); P6 15,31 (±1.19); Z1 12.17 (±1.56); Z2 9,60 (±1.56); Z3 10.79 (±3.33); Z4 9.14 (±2.06); Z5 9.77 (±2.27) and Z6 9.22 (±1.98). The shear bond strength values were lower in the P groups subjected to salivary contamination. The ICP-MS analysis revealed greater calcium ion release in all groups. Regarding phosphate ion, greater release was observed in the solution resulting from the tribological assay when the P90 composite resin specimens were tested against permanent tooth antagonists. In conclusion, there were no chemical alterations on resin surface after the mechanical wear assay and P90 composite resin presented lower shear bond strength values than Z250 composite resin. Salivary contamination affected negatively in the shear bond strength values when P90 resin composite was evaluated. Teeth used as counterbody did not have their surface altered by the incorporation of composite resin wear residues, maintaining the modulus of elasticity and nano-hardness, and the wear was more accentuated in the Z250 composite resin restorations. There was greater release of calcium ions compared with phosphate ions in all analyzed situations and the release of phosphate ions increased when P90 was subjected to tribological assay against a permanent tooth antagonist. Tribochemical stimuli simulating the masticatory cycle interfered with the shear strength of composite resin P90.
65

Resistência à degradação de restaurações em dentina sadia e afetada por cárie de dentes decíduos submetidas a desafios mecânico e cariogênico / Resistance to degradation of restorations on sound and affected dentin of primary teeth submitted to mechanical and carious challenges

Marquezan, Marcela 30 June 2008 (has links)
Este estudo objetivou investigar a resistência à degradação de restaurações de cimento de ionômero de vidro modificado por resina (CIVMR) e adesivo/resina composta sobre dentina sadia e afetada por cárie de dentes decíduos submetidas a desafio cariogênico e ciclagem mecânica, por meio de teste de microtração e nanoinfiltração. Cavidades oclusais tipo Classe I foram preparadas em 60 molares decíduos esfoliados. Metade dos dentes foi submetida ao processo de indução de cárie artificial, por meio de ciclagem de pH. Os dentes foram aleatoriamente restaurados com um dos dois materiais: um CIVRM (Vitremer®) e um sistema adesivo de condicionamento total (Adper Single Bond 2®) seguido de resina composta (Filtek Z100®). Após 24 horas de armazenagem em água a 37°C, as amostras dos grupos controle seguiram para os procedimentos de teste, enquanto as demais foram re-divididas e submetidas a dois métodos de desafio: desafio cariogênico (ciclagem de pH) e ciclagem mecânica (50.000 ciclos, 90 N, 3 Hz). Para os testes, os dentes foram seccionados em fatias seriadas de aproximadamente 1mm de espessura, das quais uma foi separada para o teste de nanoinfiltração e as demais foram seccionadas no sentido perpendicular de forma a obter espécimes em formato de palito com 1 mm2 de área, que foram fixados a uma máquina de ensaios universal e submetidos ao teste de microtração. Os valores nominais de resistência de união foram registrados em MPa e analisados por meio de ANOVA e testes de comparações múltiplas de Games-Howel (=0,05). As fatias designadas para o teste de nanoinfiltração foram impermeabilizadas com esmalte exceto nas interfaces e imersos em nitrato de prata amoniacal por 24 horas para evidenciação dos espaços nanométricos e sinais de degradação nas interfaces. Após a imersão em solução reveladora, essas fatias foram preparadas e observadas em MEV, utilizando modo de elétrons retroespalhados. A nanoinfiltração nas interfaces foi mensurada com o programa Leica QWin, registradas em m2 e analisadas por meio de ANOVA e teste de comparações múltiplas de Tukey-Kramer. A resistência de união do Vitremer não foi comprometida pela condição da dentina (sadia ou afetada). Contrariamente, o adesivo Single Bond 2® apresentou valores de resistência adesiva significativamente menores quando aderido à dentina afetada por cárie. A ciclagem mecânica não influenciou a resistência de união para ambos os materiais, enquanto o desafio cariogênico resultou em um decréscimo significativo na resistência adesiva do Adper Single Bond 2®, mas não para as restaurações de Vitremer®. O padrão de falha misto foi predominante em todos os grupos. Em relação à nanoinfiltração, o Vitremer® não apresentou diferença no padrão de infiltração em função do substrato sadio ou cariado. Em contrapartida, o adesivo Adper Single Bond 2® apresentou maiores áreas de infiltração de prata nas interfaces com dentina cariada em comparação à dentina sadia. Os desafios cariogênico e mecânico, por sua vez, não influenciaram a infiltração de prata para nenhum dos materiais e substratos. Em conclusão, o substrato cariado e o desafio cariogênico negativamente afetam o comportamento das restaurações de adesivo/resina composta, mas não afetam para as restaurações de CIVRM. / This study aimed to investigate the resistance to degradation of resin modified glass ionomer cement (RMGIC) and adhesive/composite restorations on sound and caries-affected dentin of primary teeth subjected to carious challenge and load-cycling, by means of microtensile test and nanoleakage. Occlusal class I cavities were prepared on sixty sound exfoliated second primary molars. Half teeth were submitted to pH-cycling to induce artificial caries lesion. Teeth were randomly restored with one of the two materials: (1) a RMGIC (Vitremer®) and a (2) a total-etch adhesive system (Adper Single Bond 2®) followed by composite resin (Filtek Z100®). After storage in distilled water 37°C for 24 hours, sample from control groups followed to test procedures while the other ones were re-divided and submitted to two different aging methods: carious challenge (pH-cycling) and load-cycling (50 000 cycles, 90N, 3Hz). For testing, teeth were sectioned into about 1mm slabs, from which, one was separated for nanoleakage testing and the others were perpendicularly sectioned into 1mm2 beams that were tested to failure in tension in a universal testing machine. Data on microtensile bond strengths were registered in MPa and analyzed by ANOVA and Games-Howell multiple-comparisons tests (=0.05). Slabs meant for nanoleakage testing were coated with nail varnish except for the bonded interfaces, and immersed in ammoniacal AgNO3 for 24 hours in order to disclose nanometer-sized spaces and degradation signs within interfaces. After immersion in photodeveloping solution, bonded sections were prepared and observed under SEM using the backscattered electron mode. Nanoleakage patterns at interfaces were measured using Leica QWin, registered in m2 and analyzed by ANOVA and Tukey-Kramers multiple-comparisons tests. Vitremer bond strength was not affected by dentin condition (sound or affected). Conversely, Adper Single Bond 2® showed significantly lower bond strength values when bonded to caries-affected dentin. Load-cycling did not influence bond strength for both materials. While carious challenge resulted in a significant decrease in microtensile bond strengths of Adper Single Bond 2®, but did not for Vitremer restorations. The mixed failure pattern was predominant in all groups. Concerning nanoleakage, Vitremer® did not show difference in leakage pattern between sound and caries-affected dentins. In contrast, the adhesive Adper Single Bond 2®, presented greater leakage areas at affected dentin interfaces than sound ones. The cariogenic and mechanical challenges did not influence silver penetration for none of the materials and substrates. In conclusion, the caries-affected substrate and the cariogenic challenge negatively affected the behavior of the adhesive/composite restorations, but did not affect for RMGIC restorations.
66

Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva / In vitro evaluation of systems on microtensile bond strength to orrogated dentin with endodontic solutions. Adhesive interface degradation influence

Galafassi, Daniel 27 January 2009 (has links)
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado. / The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.
67

Influência da delimitação da área adesiva no ensaio mecânico de microcisalhamento / Evaluation of adhesive area delimitation on microshear test

Shimaoka, Angela Mayumi 26 June 2007 (has links)
Este estudo teve como objetivos avaliar se a delimitação da área adesiva a ser testada no ensaio mecânico de microcisalhamento é capaz de alterar os resultados de resistência de união obtidos; determinar se a delimitação da área adesiva do ensaio mecânico de microcisalhamento pode alterar o ranqueamento dos sistemas adesivos analisados e correlacionar os tipos de fratura encontrados com valores de resistência adesiva obtidos em cada um dos grupos experimentais. As unidades experimentais foram confeccionadas sobre 18 superfícies de dentina obtidas a partir de incisivos bovinos distribuídas aleatoriamente em 3 grupos, segundo o sistema adesivo a ser utilizado (Adper Single Bond 2, Clearfil Se Bond, Clearfil S3 Bond). Desta forma foram compostos 6 grupos experimentais segundo os dois fatores de variação a serem estudados: sistema adesivo e delimitação da área adesiva. Sobre cada superfície dentinária foram confeccionados 4 cilindros em resina composta, sendo 2 com delimitação da área adesiva e 2 sem a delimitação desta área, totalizando n=12. Após 24 horas de armazenamento os espécimes foram submetidos ao ensaio mecânico de microcisalhamento. O teste estatístico ANOVA (p<0,01) e o teste auxiliar de Tukey determinaram que todos os grupos experimentais em que a delimitação da área adesiva foi realizada apresentaram menores valores de resistência adesiva quando comparados aos seus respectivos grupos controle (sem delimitação da área adesiva). Para os grupos em que não foi realizada a delimitação da área não foram observadas diferenças estatisticamente significantes entre os adesivos empregados. Em contrapartida, quando não foi realizada a delimitação, o sistema adesivo Clearfil S3 Bond mostrou maiores valores de resistência adesiva quando comparado aos sistemas Adper Single Bond 2 e Clearfil SE Bond, que por sua vez não se mostraram estatisticamente diferentes entre si. Concluiu-se que a delimitação da área adesiva no ensaio de microcisalhamento alterou os resultados de resistência adesiva obtidos, e que a modificação da metodologia do ensaio mecânico de microcisalhamento foi capaz de alterar o ranqueamento dos sistemas adesivos analisados. / This study had as objectives to evaluate if the delimitation of adhesive area on microshear test is capable to modify the values of shear bond strength; to determine if this delimitation can modify the ranking of the analyzed adhesive systems and to correlate the found types of failure with the values of bond strength in each experimental group. The specimens were confectioned on 18 incisors bovine dentine surfaces randomly distributed into 3 groups, according to adhesive system used (Adper Single Bond 2, Clearfil If Bond, Clearfil S3 Bond). In such a way, 6 experimental groups were designed according to two factors of variation to be studied: adhesive system and delimitation of the adhesive area. Over each dentin surface were confectioned 4 composite resin cylinders, being 2 with delimitation of the adhesive area and 2 without the delimitation of this area, totalizing n=12. After 24 hours of storage the specimens were submitted to microshear test Statistical test ANOVA (p<0,01) and Tukey?s test determined that all the experimental groups where the delimitation of the adhesive area was carried through presented lesser values of shear bond strength when compared with its respective control groups (without delimitation of adhesive area). Groups without area delimitation did not been demonstrate statistical significant differences between adhesives. On the other hand, when such delimitation was not carried through, the adhesive system Clearfil S3 Bond demonstrates greater values of shear bond strength compared to Adper Single 2 Bond and Clearfil SE Bond, which did not showed statistical difference between them. It was concluded that the delimitation of the adhesive area in the microshear test altered the obtained results of adhesive resistance, and that the modification of microshear test methodology was capable to modify the ranking of the analyzed adhesive systems.
68

Resistência adesiva ao cisalhamento de reparos em porcelana condicionada com laser / Shear bond strenght of porcelain repairs etched with laser

Pedrazzi, Hamilton 26 November 2007 (has links)
O objetivo foi avaliar in vitro a resistência ao cisalhamento de reparos em porcelana condicionada com laser e compará-la aos tradicionais métodos de reparo condicionados com ácido hidrofluorídrico e ácido fosfórico. Neste estudo, foram utilizados dois condicionadores químicos de porcelana (ácido hidrofluorídrico a 10% - Dentsply; ácido fosfórico a 37% - 3M ESPE), um agente silano (Rely X Silano - 3M ESPE), um sistema adesivo (Scotchbond Multi-uso - 3M ESPE), um compósito restaurador (Filtek Z250 - 3M ESPE), uma porcelana odontológica (Ceramco 3 - Dentsply) e um laser de alta potência em regime de femtosegundo (Ti:Safira - Libra- S, Coherent). Sessenta pastilhas em porcelana foram confeccionadas e incluídas e anéis de PVC com resina acrílica quimicamente ativada. As pastilhas de porcelana foram polidas com lixas abrasivas em ordem decrescente de abrasividade para o aplainamento da superfície. Foram formados 6 Grupos (n=10) assim divididos: G1 - condicionamento com laser com potência 760mW; G2 - condicionamento com laser com potência de 760mW e aplicação de ácido fosfórico a 37% por 15s; G3: condicionamento com laser com potência de 900mW; G4 - condicionamento com laser com potência de 900mW e aplicação de ácido fosfórico a 37% por 15s; G5 - aplicação de ácido fosfórico 37% por 15s (grupo controle) e G6 - aplicação de ácido fluorídrico a 10% por dois minutos. Após o condicionamento da porcelana, foi aplicado agente silano para todos os corpos de prova, seguido da aplicação do sistema adesivo e polimerização por 20s. Foram confeccionados corpos de prova de resina composta na superfície da porcelana com a inserção de camadas através de matriz bipartida e de maneira incremental (2 incrementos), com fotopolimerização de 20 segundos por incremento, utilizando aparelho fotopolimerizador (XL 3000, 3M Dental Products). Em seguida a matriz foi removida e os anéis de resina com os corpos-de-prova confeccionados removidos do porta matriz e submetidos à nova fotopolimerização por mais 20 segundos. Depois de confeccionados os corpos-deprova foram levados á máquina de termociclagem por 1000 ciclos de 30 segundos em cada banho com temperatura entre 5ºC e 55ºC. Após a termociclagem os corpos-de-prova foram submetidos ao ensaio de cisalhamento. Os resultados foram avaliados estatisticamente por análise de variância (ANOVA 1 fator de variação) e teste de Tuckey (alfa=0,05). As médias e desvio padrão foram: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (letras iguais demonstram não haver diferença entre grupos). / The aim of this study was to evaluate in vitro the shear bond strength of repairs in porcelain conditioned with laser and to compare it to the traditional repair methods conditioned with hydrofluoric acid and phosphoric acid. In this study, were used two conditioning porcelain (10% hydrofluoric acid - Dentsply; 37% phosphoric acid - 3M ESPE), a silane agent (Rely X Silano - 3M ESPE), an adhesive system (Scotchbond Multi-uso - 3M ESPE), a composite resin (Filtek Z250 - 3M ESPE), a porcelain (Ceramco 3 - Dentsply) and a laser of high potency in femtosecond (Ti:Safira Libra-S, Coherent). Sixty porcelain discs were made and embedded in PVC rings using a polymethyl methacrylate resin. All specimen were smoothed with abrasive sandpapers in decreasing order of abrasiveness for the leveling of the surface. Six Groups were formed (n=10) being divided: G1 - conditioning with laser with potency 760mW; G2 - conditioning with laser with potency of 760mW and application of 37% phosphoric acid for 15s; G3: conditioning with laser with potency of 900mW; G4 - conditioning with laser with potency of 900mW and application of 37% phosphoric acid for 15s; G5 - application of 37% phosphoric acid for 15s (group control) and G6 - application of 10% hydrofluoric acid for two minutes. After the conditioning of the porcelain, silane agent was applied for all of the specimens, following by the application of the adhesive system and photoactivation for 20s. Specimens of composed resin were made in the surface of the porcelain aided with a metal matrix and insert of incremental layers (2 increments) with photoactivation of 20 seconds for increment. The photoactivation was performed with a visible light unit (XL 3000, 3M Dental Products). Afterwards the metal matrix was removed and the specimens were submitted to the new photoactivation for more 20 seconds. The specimens were submitted a thermal cycling by 1000 cycles of 30 seconds in each bath with temperature between 5ºC and 55ºC. After the thermal cycling , specimens were submitted to the shear bond strength. The results were evaluated statistically through analysis of variance - ANOVA One Way and Tuckey test (alfa=0,05). The averages and standard deviation: G1 - 11,25 ± 3,10(ab); G2 - 12,32 ± 2,65(ab); G3 - 14,02 ± 2,38(a); G4 - 13,44 ± 2,07(a); G-5 - 9,91 ± 2,18(b); G6 - 12,74 ± 2,67(ab), (same letters demonstrate there not to be difference among groups).
69

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Serrano, Luisa Julieth Parra 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.
70

Estudo da resistência adesiva de cimentos de ionômero de vidro à dentina: microtração x microcisalhamento / Bond stregth of glass-ionomer cements to dentin: microtensile x microshear

Bonifacio, Clarissa Calil 29 October 2008 (has links)
Este estudo objetivou avaliar quantitativamente e qualitativamente a resistência adesiva de três diferentes tipos de cimentos de ionômero de vidro (CIV) por meio dos ensaios mecânicos de microtração e microcisalhamento. Quarenta superfícies planas de dentina foram divididas aleatoriamente em dois grupos, segundo o ensaio mecânico: microtração (n=24) e microcisalhamento (n=16). Posteriormente, cada grupo foi novamente dividido em quatro subgrupos, segundo o material restaurador utilizado: CIV de alta viscosidade (Ketac Molar Aplicap - 3M/ESPE), CIV modificado por resina (Fuji II LC encapsulado - CG Corporation), nano-ionômero (Ketac N100 - 3M/ESPE) e resina composta (Z100 - 3M/ESPE). Para o teste de microtração os dentes foram seccionados perpendicularmente a interface de união obtendo-se espécimes com área de superfície aderida de aproximadamente 1mm2. Para o teste de microcisalhamento foram confeccionados três cilindros de material restaurador em cada superfície de dentina. Todos os grupos foram armazenados em água destilada por 24h. Os ensaios foram realizados em Mini Instron a velocidade de 1mm/min. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p<0,05) e o método de comparações múltiplas LSD. Foi encontrada diferença estatisticamente significante entre testes e entre materiais, demonstrando que o comportamento dos valores de resistência adesiva dos quatro tipos de materiais estudados depende do tipo de ensaio mecânico utilizado. A análise qualitativa dos padrões de fratura em lupa estereoscópica revelou fraturas predominantemente adesivas e mistas quando da utilização do microcisalhamento para todos os materiais estudados, enquanto para a microtração, observou-se um grande número de fraturas coesivas em material para o Ketac Molar e para o Fuji II LC. Os valores de resistência adesiva do Ketac Molar e do Fuji II LC são semelhantes aos encontrados à resina Z100, quando o teste utilizado foi o microcisalhamento. Com o teste de microtração houve diferença entre os grupos, sendo que Ketac Molar se comportou de maneira semelhante a N100 que foram estatisticamente inferiores a Fuji II LC, que por sua vez também foi inferior a Z100. Com base nesses resultados conclui-se que o ensaio mecânico de microcisalhamento foi o que melhor avaliou a resistência adesiva dos materiais ionoméricos. / The present study aim to quantitatively and qualitatively evaluate the adhesive resistance of three types of Glass Ionomer Cements (GIC) through microtensile and microshear tests. Forty flat dentine surfaces were randomly divided between the two types of mechanical test: microtensile (n=24) and microshear (n=16). Furthermore, each group was divided into four subgroups, according the material used: High Viscosity GIC (Ketac Molar Aplicap - 3M/ESPE), Resin Modified GIC (Fuji II LC encapsulated - CG Corporation), nano-ionomer (Ketac N100 - 3M/ESPE) and composite resin (Z100 -3M/ESPE) resin. For the microtensile test, the teeth were sectioned perpendicularly to the adhesive interface so 1mm2 surface specimens could be obtained. For the microshare test three cylinder shaped restorative material were produced per each dentine surface. All groups were stored in distillated water for 24h. All tests were performed with a Mini Instron machine at a crosshead speed of 1mm/min. The results obtained, expressed in MPa, were submitted to variance - ANOVA (p<0,05) and least significant differences (LSD) analysis. Test and materials were statistically different, indicating that the values for adhesive resistance obtained per material depend on the test used. The qualitative analysis of the fractures, carried out by light microscope at 40x magnification, revealed that fracture produced by the microshear test were mainly adhesives or mixed. Microtensile fractures were mainly cohesive within the material for Ketac Molar and for Fuji II LC. According to the microshear test, the adhesive resistance figures found for Ketac Molar and for Fuji II LC were similar to the ones found in Z100 resin. Nevertheless, the microtensile test demonstrated that there was difference between the groups, as Ketac Molar behaved in line with N100, which were statistically inferior to Fuji II LC that was poorer than Z100. The conclusion, base on these results, was that the microshear was the mechanical test that better evaluated the adhesive resistance of the studied ionomer-based materials.

Page generated in 0.0641 seconds