291

Utvärdering av Skvallertorget i Norrköping / Evaluation of Skvallertorget in Norrköping

Jaredson, Sofia January 2002 (has links)
<p>This thesis is an evaluation of the new traffic solution at “Skvallertorget”. The innovative theory behind it is to increase traffic-safety by introducing insecurity feelings for road-users. </p><p>The conclusion of the evaluation is that the newtraffic solution is well adjusted according to guidelines for municipal traffic planning. The evaluation also illustrates the conflict between traffic planners deliberate attempt to avoid clear information and the road users wish to get it. The paradoxical situation is that the forced insecurity feelings on the road users seems to be required to increase the attention and thus the traffic safety.</p>
292

Byggprojektstyrning med hjälp av dator -Studie utförd vid byggföretaget NCC / Construction project management by help from computor -A study made at the constuction company NCC

Hellman, Pär January 2002 (has links)
<p>Styr is a computer program that the construction company NCC use in their construction projects. The program is used to keep the economy of their projects in a good order and things for the best in an early phase. </p><p>The problem is a low extent of utilization. During the latest decade NCC has put a lot of job and money trying to develop the program. The question is how to get the employees to use the program in a greater extent. </p><p>The aim of this graduationwork is to examine how to make the employees to utilize Styr better than they do today. My work contains specification from inquiry made by NCC and an inquiry made by my self. My inquiry was sent to productions employees. My work also contains a study literature about arrangement of projects and interviews with persons who are responsible for the program. </p><p>The study has shown that the low extent of utilization do not depends on the single user but the whole company, from managing director down to production manager.</p>
293

Sund inomhusmiljö Studie av betonggolv och dess ytskikt / Healthy indoor environment Study of concrete floors

Linnersund, Malin, Litzleäng, Elin January 2002 (has links)
<p>Detta examensarbete behandlar ämnet sunda hus. Vi har studerat betongplattan med dess ytskikt för att se dess påverkan på inomhusmiljön. Anledningen till att denna rapport har skrivits är att NCC, i samarbete med Stångåstaden AB, är intresserade av att få reda på materials påverkan på inomhusmiljön. Studien har utförts i Linköping på Kv. Irrblosset vilket uppförs som ett sunt studentboende. </p><p>Vi har delat upp examensarbetet i två studier, betongstudie och en studie av betonggolvens ytskikts. För att öka förståelsen för ämnet har vi gjort en grundlig teoretisk referensram. </p><p>Betongstudien har utförts med hjälp av studiebesök och intervjuer. För att påskynda uttorkningstiden hos betongen anser vi att vibreringsfri och snabbtorkande betong är lämpliga val för att åstadkomma en sund inomhusmiljö. </p><p>Valda ytskikt på Kv. Irrblosset har utifrån miljö, kvalitet och hälsa studerats. Vi har sedan angett förslag på alternativa ytskikt som kan användas för att öka inomhuskomforten. Exempel på ytskikt som är speciellt lämpade för en sund inomhusmiljö är löslagda trägolv och linoleum som är valt på Kv. Irrblosset. </p><p>Efter våra intervjuer har vi kommit fram till att ett kvalitetsarbete är viktigt för att uppnå en sund inomhusmiljö. Kvalitetsarbete måste genomsyra hela företaget från ledning till produktion. Kvalitet kan definieras som en ständig strävan för att bli bättre. </p> / <p>This graduate work discusses the subject healthy buildings. We have studied concrete floor and floor materials to find out their influence on the indoor environment. The reason that this graduate work was written is that NCC in corporation with Stångåstaden AB are interested in materials influence on the indoor environment. The study has been accomplished in Linköping at Kv. Irrbloset, which is built as a healthy building for students. </p><p>Our graduate work contains two different studies, a study about concrete and a study about concrete floor’s material. We have done a thorough literature study to enlarge our comprehension about the subject. </p><p>The study that discusses concrete has been accomplished by interviews and educational visits. To speed up the time of desiccation in concrete structures a use of vibration free concrete and fast drying concrete are suitable choices to get a healthy indoor environment. </p><p>Chosen floor materials at Kv. Irrblosset have been studied from an environmental, quality and health kind of view. We have recommended alternative materials that can be used to increase the quality of the indoor environment. Floor materials that are especially suitable for a healthy indoor environment are wooden floors with no glue and linoleum. </p><p>After several interviews we figured out that quality work is very important to reach a healthy indoor environment. Quality work must be a part of the whole company and a definition of quality can be a permanent aspiration to become better.</p>
294

Pålade plattor för stora laster : En jämförelse mellan nätarmerade och fiberarmerade betong plattor / Piled Slabs for Heavy Loading : A comparison between mesh reinforced and fiber reinforced concrete slabs

Simmons, Gustav January 2002 (has links)
<p>Funktionskraven på industrigolv har under senare år ökat. Ett industrigolv skall klara att överföra laster till underlaget samt utgöra ett fast och plant underlag. I denna rapport har två utföranden av påldäck för golv i lagerlokaler jämförts. Den traditionella metoden med armeringsnät har jämförts med en något nyare metod med stålfiberarmerad betong. Jämförelserna har gjorts under förutsättning att golvet skall belastas med 3 ton per kvadratmeter. Kostnader, tidsåtgång såväl som produktionstekniska egenskaper har undersökts. En undersökning av förhållandet mellan pålavstånd och plattutformning har också gjorts. </p><p>Ett referensobjekt har valts och dess förutsättningar har legat till grund för jämförelsen. Information från arbetsplatser, underentreprenörer och kalkyler har sammanställts för de två metoderna. Kalkyler och tidplaner har sedan upprättats och jämförts. </p><p>Fiberarmerad betong är dyrare än nätarmerad betong. Med avseende på tid är fiberbetongen det klart bättre alternativet. Ur produktionssynpunkt är fiberbetongen att föredra förutom vid de fall då golvvärme önskas. Resultaten visar att fiberbetong kan vara en lönsam lösning för golv med krav på stora laster då man vill komma in i byggnaden i ett tidigt skede. </p><p>Resultatet av jämförelsen mellan pålavstånd och plattutformning bör utredas närmare för att säkerställa att bästa plattutformning används. </p> / <p>The demands on industrial flooring have increased. The floor has to be able to transfer load to the substructure and function as a plain solid surface. This report compares two different methods of the construction of piled slabs. The traditional method with mesh reinforced concrete is compared with a method using concrete reinforced with steel fibers. The comparison is made under condition of a 30 kN/m2 load. The investigation includes cost, time consumption and production factors. An investigation of the relation between pile distance and slab design will also be done. </p><p>A reference object has been chosen. Both construction methods have been investigated using the current conditions connected to the object. Information from construction sites, subcontractors and cost estimates has been put together. Updated cost estimates and time plans have been created and compared. </p><p>The fiber reinforced concrete is more expensive than mesh reinforced concrete. Fiber reinforced concrete consumes less time than mesh reinforced concrete and is more favorable when production factors are compared. Fiber reinforced concrete can’t be used together with under-floor heating. </p><p>The result states that fiber reinforced concrete can be a profitable solution for slabs with heavy loads and demands for an early entrance to the building. The result from the relation between pile distance and slab design should be investigated further to make sure the most favorable slab design is used.</p>
295

Dataprogram för beräkning av pålfundament och felslagning av pålar / Computer program to calculate piling foundation and mispiling

Dahlqvist, Thomas, Parbrand, Mårten January 2002 (has links)
<p>Syftet med detta examensarbete är att producera ett dataprogram som dimensionerar pålfundament samt beräknar felslagning av pålar. Ett pålfundaments funktion är att via pålar överföra laster till berg eller fasta jordlager. Felslagning inträffar då pålar inte hamnat på rätt koordinater eller glidit snett ned i marken och ej kan användas. Med hjälp av felslagningsprogrammet erhålles nya påkoordinater för nästkommande påle, vilken måste placeras ut så att tyngdpunkten för hela pålsystemet skall hamna rätt. Programmeringsspråket vi använt oss av är Visual Basic, där vi har omvandlat teoretiska beräkningar till databeräkningar. Detta har resulterat i ett dataprogram som beräknar 2-, 3- och 4-pålsfundament samt tar fram en ny påles koordinater vid felslagning. Vid beräkning av pålfundament tas hänsyn till armeringsmängd, förankring, sprickbildning samt spjälkning.</p>
296

Fuktsäkerhetsbedömning med Wufi / Moisture safety assessment with Wufi

Fredriksson, Eric, Svensson, Mattias January 2009 (has links)
Fuktsäkerhet är ett växande begrepp inom byggbranschen och det läggs ner mer och mer tid på att konstruktioner ska bli fuktsäkra. Fukt är komplicerat att beräkna och det kan därför underlätta att använda ett beräkningsprogram som hjälpmedel. Wufi är ett tyskt fuktberäkningsprogram som nyligen har utkommit i en svensk version. Detta program har WSP investerat i för att lättare kunna bedöma fuktsäkerheten i konstruktioner. WSP var intresserade av en studie av Wufi för att underlätta introduktionen av programmet i företaget. Målet med rapporten är att klargöra hur grundläggande parametrar ska beaktas i programmet och hur tillförlitligt programmet är.   För att möjliggöra en bedömning av programmet inleddes arbetet med självstudie av programmet, som avslutades med en kort utbildning i programmet. Efter detta utfördes ett antal parametertester i programmet för att få svar på hur dessa skall hanteras. För bedömningen av tillförlitligheten i programmet utfördes därefter en större studie på putsväggar med olika putssystem. Beräkningsresultaten från programmet jämfördes med de problem som har uppstått på dessa konstruktioner.   Parametertesterna visar att materialegenskaperna har stor påverkan på resultatet och det är således viktigt att använda material på rätt sätt och med rätt värden. Val av tidssteg för beräkningarna ger ingen större skillnad i resultat. Beräkningar i programmet kan därav utföras med en timmes tidssteg och på så sätt minimera beräkningstiden.   Används Wufi och dess parametrar på rätt sätt ger programmet tillförlitliga resultat. Resultaten från de beräknade putsväggarna i Wufi följer de problem och diskussioner som har uppkommit kring puts på träregelväggar. Programmet är dock helt beroende av vad man väljer för indata och materialegenskaper. Kontrollerar man inte dessa noga finns det risk för att resultatet blir felaktigt och då försvinner även tillförlitligheten till programmet.   För att programmet skall få en slagkraft i en organisation som WSP, bör en genomarbetning av materialdatabasen att utföras. Detta ökar användarvänligheten betydligt och projektörer som normalt inte jobbar med byggnadsfysik skulle då kunna bedöma fuktsäkerheten i ett aktuellt projekt. För att bibehålla kontrollen över fuktsäkerheten bör det dock finnas tydliga föreskrifter för hur programmet skall användas. / Moisture safety is a rising concept in the construction industry and building designers spent more and more time on the moisture safety designs. Moisture is complicated to calculate and the use of a calculation program could make the process easier. Wufi is a German moisture calculation program that recently has been presented in a Swedish version. WSP has invested in the program to better assess the moisture safety in structures. WSP was interested in a study of Wufi to facilitate the introduction of the program in the company. The objective of this report is to clarify how the basic parameters are to be considered in the program and how reliable the program is.   In order to make an evaluation possible the process started with self-study of the program, and ended with a short education in the program. After this a number of parametric tests were conducted in the program to answer how these should be dealt with. For the assessment of the reliability of the program a major study on plaster walls with different plaster system was made. The results were compared with the problems that have occurred on these structures.   The parameter tests shows that material properties have a major impact on the outcome and it is therefore important to use materials in the right way and with the right values. The test of time steps indicates small difference in outcome. Calculations in the program can therefore be carried out with an hour time step and thus minimizing the calculation time.   Used correctly, the Wufi program and its parameters provides reliable results. The result from the plaster walls in Wufi follows the implications and discussions that have aroused about the plaster on wood frame. However, the application is entirely dependent on what you choose for input and material properties. If these are not carefully controlled, there is a risk that the results are wrong and the reliability of the program is then gone.   For the program to reach a useful position in an organization such as WSP, an update of the material database ought to be done. This increases the usability significantly and building designers who do not normally work with building physics could then be able to determine the moisture safety in a construction. In order to maintain control over moisture safety, however, there should be clear policies for how the program should be used.
297

Energibesparing åt Klövern AB : Förslag på åtgärder för minskad driftkostnad för Klövern AB’s fastigheter / Energy saving för Klövern AB : Proposed measures to reduce operating costs

Eriksson, Per, Trygg-Svensson, Sebastian, Österbring, Magnus January 2010 (has links)
Fastighetsbolaget Klövern AB förvaltar 45 fastigheter i Karlstad kommun. Med stigande energipriser ökar behovet för Klövern att energieffektivisera sina fastigheter för att minska kostnaderna. Rapportens syfte är att undersöka tre av Klövern utvalda fastigheter med hög energiförbrukning. Målet är att presentera energibesparande åtgärder för Klövern att använda som beslutsunderlag för framtida investeringar. För åtgärdsförslagen görs LCC-analyser för att undersöka om de är lönsamma. Därefter görs känslighetsanalys för de mest lönsamma alternativen för att tydliggöra osäkerheten i beräkningsunderlaget. De åtgärder som rekommenderas har ett positivt nuvärde efter livslängd, rangordning av dessa alternativ görs sedan efter avkastning. De tre fastigheterna är Gripen 11, Blåsten 4, Styrmannen 5.   För Gripen 11 undersöktes möjligheterna att installera solfångare, åtgärda ventilationssystem och att tilläggsisolera vissa delar av fastigheten. Resultatet visar att de bästa energibesparingsåtgärderna är att öka temperaturverkningsgraden för värmeväxlare i system 1 vilket ger en besparing på ca 135000 kWh/år samt att optimera drifttiden för system 2 vilket ger en besparing på ca 17000 kWh/år. Installation av 110 kvm solfångare ger en årlig energibesparing på ca 48000 kWh/år.   Blåsten 4 består av en huvudbyggnad med fyra ventilationssystem samt en lagerlokal med luftvärmepumpar. För fastigheten undersöktes effekten av att ersätta ventilationssystem 2, 3 och 4 med ett nytt gemensamt ventilationssystem med värmeväxlare. Undersökningar har gjorts för hur lönsamheten ser ut för att byta uppvärmningssystem från, i dagsläget, direktverkande el. Nya system som undersöktes är bergvärme, fjärrvärme, en kombination av dessa samt luft/vatten-värmepump. Vid byte av uppvärmningssystem inkluderas installation av radiatorsystem. Analys av lönsamhet för tilläggsisolering, solceller och solfångare har genomförts. Resultatet visar att åtgärda ventilationssystemen enligt ovan ger en energibesparing på ca 235000 kWh/år. Att byta uppvärmningssystem till fjärrvärme ökar energikonsumtionen med ca 70000 kWh/år men ger en besparing på ca 130000 kr/år då fjärrvärme är ett billigare alternativ än direktverkande el (kr/kWh). Installation av solfångare med bidrag från Boverket är lönsamt och ger en energibesparing på ca 8800 kWh/år.   Styrmannen 5 består av två byggnader med kontorsverksamhet. Fastigheterna är fristående men binds ihop av ett garage under marken som värms upp till 12 grader. Tre ventilationssystem med värmeväxling finns i byggnaderna samt frånluftssystem. Liknande förutsättningar gäller för båda fastigheterna, stora delar av fasaderna består av fönster och FTX-systemen har relativt hög verkningsgrad. Mellan husen finns en park som i dagsläget är uppvärmt med markvärme under vinterhalvåret för att hålla den snöfri. De åtgärdsförslag som undersökts för att minska energianvändningen är dels att installera ventilationssystem med högre verkningsgrad än vad som idag finns, bygga om ett ventilationssystem för att värma garaget med frånluft, helt stänga av uppvärmningen av garaget samt att snöröja parken manuellt istället för med markvärme. Resultatet visar att installation av nya ventilationssystem inte klarar lönsamhetskraven, åtgärder medför en energibesparing för hus A på ca 24000 kWh/år och för hus B ca 15500kWh/år. Däremot klarar ombyggnationen av ventilationssystemet för att värma garaget lönsamhetskravet och sparar ca 140000 kWh/år. Då åtgärderna att snöröja istället för markvärme samt att helt stänga av uppvärmningen av garaget inte har någon investeringskostnad kan avkastning inte beräknas, dessa åtgärder skulle dock spara ca 180000 kWh/år respektive ca 95000 kWh/år. / The real estate company Klövern LTD manages 45 properties in Karlstad. With rising energy prices the necessity to be more energy efficient in their properties to reduce costs, increases. The reports purpose is to examine three of Klöverns worst properties concerning high energy consumption. The goal is to introduce energy saving measures to Klövern which will be used as a basis for future investments. LCC-analyses are made to examine whether or not different modifications and installations are profitable. Sensitivity analysis is done for the most viable options to clarify the uncertainty in the calculations e.g. investment cost, inflation. The recommended actions have a positive LCC-value under their life-span, the ranking of these alternatives are then made after how much they yield under their life-span. The three properties that are examined are Gripen 11, Blåsten 4, Styrmannen 5. For Gripen 11 surveys where made for the possibility of installing solar panels, installation of  new heat exchangers to some of the ventilation system and to put in additional insulation in certain parts of the property. Results show that the best energy saving measures is to increase the temperature efficiency of heat exchangers in system one which gives a saving of approximately 135 000 kWh/year, and to optimize the operating time of system two resulting in a saving of approximately 17 000 kWh/year. Installation of 110 square meters of solar collectors provide an annual energy saving of approximately 48 000 kWh/year. Blåsten 4 consists of a main building with four ventilation systems and a warehouse with heat pumps. For this property, studies where made as to the effect of replacing three ventilation systems (2, 3 and 4) with one new ventilation system with a heat exchanger. Studies have been undertaken for the profitability of changing the heating system from, the current situation, heating by electricity. New heating systems that were investigated where geothermal heating, district heating, a combination thereof, and air/water heat pump. The replacing of the heating system includes an installation of radiator systems. Analyses of the profitability of solar cells and solar panels have also been made. The results show that to modify the ventilation systems, as described above, provides an energy saving of approximately 235 000 kWh/year. Replacing the heating system with district heating will increase the energy consumption by about 70 000 kWh/year, but will give a saving of approximately 130 000 SEK/year because district heating is a cheaper alternative than heating with electricity (SEK/kWh). Installation of solar panels, with grants from Boverket, is profitable and provides an energy saving of about 8800 kWh/year. Styrmannen 5 consists of two office buildings. The buildings are independent but bound together by an underground garage which is heated to 12 degrees. Three ventilation systems with heat exchange and one exhaust system without exists in the buildings. Similar conditions apply to both buildings, large parts of the facades are made up of windows and the heat exchangers in the ventilation systems have a rather high efficiency. Between the houses there is a park which is heated by ground heat in the winter to keep it free from snow. Studies were made to examine the effects of installing a new heat exchange system with high efficiency to reduce energy use, rebuild one of the ventilation systems in order to use the exhaust air to heat the garage, al together turn off the heating of the garage and to remove the snow manually instead of using ground heat. The results show that installing a new heat exchange systems will not be profitable. Rebuilding one of the ventilation systems to heat the garage is profitable and saves approximately 140 000 kWh/year. The measures to manually remove snow in the winter instead of ground heat, and turning of the heating of the garage would save about 180 000 kWh/year respectively approximately 95 000 kWh/year.
298

Framtidens energieffektiva flerbostadshus / Future energy effective multi-dwelling buildings

Bäckström, Carolin, Gauffin, Emma January 2010 (has links)
The housing sector of today represents for almost 40% of the energy consumption, an energy consumption of which the major part consists of non-renewable energy sources. This is not sustainable and utilization of new energy-efficient technologies in buildings can be a step in the right direction, towards a sustainable energy society. This report has been made on behalf of and in cooperation with Älvstranden Utveckling AB in Gothenburg to examine how future energy-efficient technologies can affect the energy demand in energy-efficient multi-dwelling buildings. The report is based on Älvstrandens passive house, Hamnhuset, a house whose energy consumption is far below the BBR's requirements. The report looks at the opportunities for improvement within windows, insulation, solar energy technologies, as well as white goods. Computer simulations are then made to apply the selected technologies into a reference building. Technologies are selected from an energy efficient perspective and no account has been taken of other aspects such as the economy. They must also be available on the market within a ten-year period. Information has been gathered through interviews and contacts with experts in their respective fields, as well as representatives of the various technologies. By using high-efficient insulation and smart windows, heat transmission losses and thus the heat demand can be reduced. Increased solar irradiation through the windows during the winter months also contributes to a reduction in need of purchased energy during the coldest part of the year, when the supply of renewable energy is minimal. A large part of the needed electricity may be covered by electricity from solar cells mounted on the roof, balcony fronts and facades. A reduction of purchased electricity has a major impact on the building's stress on the environment and carbon dioxide emissions from a life cycle perspective. That is also why electricity heated white goods are exchanged into appliances on district heating. By installing a larger amount of and more efficient solar collectors which also has a smoother heat production over the year, the need for heating domestic hot water is reduced. The calculations are made in two stages, the first sets out the various technologies effectiveness and potential individually; several simulations have been made for one and the same technology to provide different variations depending on the situation it is used. For example, several combinations of windows are tested in different orientations. In step two, the techniques with the greatest energy saving potential are selected in order to jointly result in a final house. To see how a future streamlining of household technology and lighting affects the energy balance of a building, a simulation is also made where household electricity is reduced by 40%. The result of selected energy efficiency measures shows a reduction of the specific energy demand by 70 % compared to the BBR's requirements and 50 % compared to the reference house. In addition the environmental impact of the building reduces from a CO2 perspective with 85 % compared to the reference house. However, there is an uncertainty of the results as they are based on speculations in the technologies future capacity. Results should therefore be seen as an inspiration for how high the objectives can be set in the construction of energy-efficient buildings. Still, in the light of this report, there are great opportunities to within a ten-year period build multi-dwelling buildings that are way more energy efficient than today.
299

Knäckning av träreglar

Sadic, Damir, Gröndahl, Max January 2010 (has links)
<p>En stor andel av Sveriges enfamiljshus byggs i trä. Väggen i ett sådant hus är typiskt en skivbeklädd regelvägg. Målet med detta examensarbete är att studera lastkapaciteten hos träreglar i sådana väggar. Olika randvillkor gäller i de tre olika uppställningarna som studerats. Genom att variera randvillkoren undersöks vilken inverkan en syll och en skiva har för att styva av knäckning i veka riktningen. Detta görs genom tre olika uppställningar. Första uppställningen omfattar endast en regel. Regeln kommer att vara ledad i överkant och underkant. I uppställning 2 byts leden i underkant ut mot en syll, och i uppställning 3 tillkommer förutom syll även en gipsskiva som skruvas fast i regeln och i syllen i underkant.</p><p>Resultaten ska ge förståelse för hur reglar med olika randvillkor beter sig vid successivt ökande last. Även ge information som kan användas för praktiska och teoretiska modeller.           </p><p>Resultaten visade att en regel som sägs vara stagad i veka riktningen, där brott väntas i styva riktningen, inte alltid är ett korrekt antagande. Uppställningarna som testades i detta experiment knäckte i veka riktningen. Reglarna i uppställning 3 knäckte i veka riktningen vid en last som var ca 11 % högre än vad som beräknats för knäckning i styva riktningen. Utifrån dessa experiment är det en acceptabel approximation att räkna att kapaciteten är minst då knäckning sker i styva riktningen.</p>
300

Digitalt byggande

Molin, Olof January 2010 (has links)
No description available.