• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • 1
  • Tagged with
  • 7
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigation on the Adsorption of Mercury Chloride by Powdered Activated Carbon¡GOperation Parameters and Adsorption Isotherm

Liu, Ming-Han 14 September 2001 (has links)
The objective of this study was to investigate the removal of mercury chloride in flue gas emitted from municipal waste incinerator (MWI) by the adsorption of powdered activated carbon derived from the pyrolysis of waste tires (PAC-T). This study focused on the removal efficiency of mercury chloride and the adsorption capacity of PAC-T. The operation parameters investigated included temperature (30¢J and 150¢J) and powdered activated carbon injection rate (0.1, 0.2 and 0.3 g/hr). Experimental tests were conducted by the following three steps¡G the adsorption column test, the adsorption isotherm simulation, and the removal efficiency test in a pilot plant. The adsorption capacity of PAC-T for various inlet mercury chloride concentrations (55~215£gg/m3) at room temperature (30¢J) were 811~2,188£gg-HgCl2/g-PAC, while the absorption capacity of PAC-T at 150¢J were 214~700£gg-HgCl2/g-PAC which were lower than those at room temperature. It suggested that the adsorption capacity of PAC-T decreased as adsorption temperature increased. Furthermore, the adsorption of mercury chloride by PAC-T was an unfavorable adsorption isotherm. The adsorption column tests were performed to assess the rate of mercury chloride uptake by PAC-T at 30 and 150¢J. Results from the adsorption isotherm simulation indicated that mercury chloride at room temperature (30¢J) can be simulated by the Redlich and Peterson isotherm. However, the adsorption of mercury chloride at 150¢J can be simulated by the Langmuir isotherm. Experimental results from the pilot tests indicated that the removal efficiency of mercury chloride increased gradually with retention time and then leveled off as retention time was higher than thirty minutes. Moreover, the removal efficiency of mercury chloride increased dramatically as PAC-T injection rate increased from 0.1 to 0.3 g/hr. The highest removal efficiency of mercury chloride which can be achieved by waste-tire derived powdered activated carbon (PAC-T) and commercial powdered activated carbon (PAC-C) were 86.5% and 98.9%, respectively. In general, PAC-T was comparative to PAC-C for the removal of mercury chloride from flue gas on the basis of both physical and chemical properties and removal efficiency of mercury chloride.
2

Determinação de mercúrio em amostras ambientais por espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite com superfície modificada / Determination of mercury in environmental samples by atomic absorption spectrometry with electrothermal atomization in graphite furnace with modified surface

Ruben Gregorio Moreno Moreno 29 March 2001 (has links)
Um procedimento eletroquímico para deposição de paládio no interior de um tubo de grafite para modificação química permanente e um sistema de geração de vapor frio para a determinação de níveis traços de mercúrio em água e sedimento através de espectrometria de absorção atômica é proposto. A célula eletroquímica tubular para as deposições de paládio em fluxo foi construída aproveitando a estrutura original do tubo de grafite o qual opera como eletrodo de trabalho. Um tubo de aço inoxidável, posicionado na saída da célula, é usado como o eletrodo auxiliar. O valor do potencial aplicado no eletrodo de grafite é medido contra um micro eletrodo de referência de Ag/AgCl inserido sobre o eletrodo auxiliar. Soluções de paládio em tampão de acetato (100 milimol L-1, pH=4,70), numa vazão de 0,5 mL min-1 foram usados para executar a deposição eletroquímica durante o intervalo de tempo de 60 min. O sistema de geração de vapor frio consiste de um micro-reator de polietileno e frasco separador líquido-gás, volume total de 4,0 ml, que é descartado depois de cada amostragem para evitar inter-contaminação das amostras. Volumes de 1,0 ml de reagente (2,0% m/v NaBH4 em 0,10 mol L-1 de NaOH) e 1,0 ml de soluções analíticas ou amostras em 0,25 mol L-1 de HNO3 são levados para o reator e separador líquido-gás usando uma bomba peristáltica. O vapor de mercúrio é transportado ao tubo de grafite modificado eletroquimicamente com fluxo de argônio de 212 ml min-1 e pré-concentrado durante 120 s. O limite de detecção obtido foi 93 ng L-1 (n=20, 3δ). O desempenho deste sistema foi testado para determinação de mercúrio em água potável, água não potável e sedimentos de lagoa. A confiança de todo procedimento foi confirmada através de testes de recuperação. / An electrochemical procedure for palladium deposition on the inner of a graphite tube for permanent chemical modification and a cold vapor generation system for the determination of trace levels of mercury in water and sediment by atomic absorption spectrometry are proposed. The tubular electrochemical cell for the deposition of palladium was assembled on the original geometry of a graphite tube that operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, is used as the auxiliary electrode. The potential value applied on the graphite electrode is measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 milimol L-1, pH=4.70), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical deposition. A cold vapor generation system consist of a micro polyethylene reactor and gas-liquid separator flask, total volume of 4.0 mL, that is discarded after each sampling to avoid intercontamination of the samples. Volumes of 1.0 mL of reagent (2.0% m/v NaBH4 in 0.10 mol L-1 of NaOH) and 1.0 mL of reference or sample solutions in 0.25 mol L-1 of HNO3 are carried out to the reactor and gas-liquid separator by using a peristaltic pump. The mercury vapor is transported to the graphite tube electrochemically modified with argon flow (200 mL min-1) and pre-concentrated during 120 s. The detection limit obtained was 93 ng L-1 (n=20, 3δ). The performance of these system was tested for determination of mercury in potable and non-potable water and lake sediments. The reliability of the entire procedure was confirmed by recovery tests.
3

Determinação de mercúrio em amostras ambientais por espectrometria de absorção atômica com atomização eletrotérmica em forno de grafite com superfície modificada / Determination of mercury in environmental samples by atomic absorption spectrometry with electrothermal atomization in graphite furnace with modified surface

Moreno, Ruben Gregorio Moreno 29 March 2001 (has links)
Um procedimento eletroquímico para deposição de paládio no interior de um tubo de grafite para modificação química permanente e um sistema de geração de vapor frio para a determinação de níveis traços de mercúrio em água e sedimento através de espectrometria de absorção atômica é proposto. A célula eletroquímica tubular para as deposições de paládio em fluxo foi construída aproveitando a estrutura original do tubo de grafite o qual opera como eletrodo de trabalho. Um tubo de aço inoxidável, posicionado na saída da célula, é usado como o eletrodo auxiliar. O valor do potencial aplicado no eletrodo de grafite é medido contra um micro eletrodo de referência de Ag/AgCl inserido sobre o eletrodo auxiliar. Soluções de paládio em tampão de acetato (100 milimol L-1, pH=4,70), numa vazão de 0,5 mL min-1 foram usados para executar a deposição eletroquímica durante o intervalo de tempo de 60 min. O sistema de geração de vapor frio consiste de um micro-reator de polietileno e frasco separador líquido-gás, volume total de 4,0 ml, que é descartado depois de cada amostragem para evitar inter-contaminação das amostras. Volumes de 1,0 ml de reagente (2,0% m/v NaBH4 em 0,10 mol L-1 de NaOH) e 1,0 ml de soluções analíticas ou amostras em 0,25 mol L-1 de HNO3 são levados para o reator e separador líquido-gás usando uma bomba peristáltica. O vapor de mercúrio é transportado ao tubo de grafite modificado eletroquimicamente com fluxo de argônio de 212 ml min-1 e pré-concentrado durante 120 s. O limite de detecção obtido foi 93 ng L-1 (n=20, 3δ). O desempenho deste sistema foi testado para determinação de mercúrio em água potável, água não potável e sedimentos de lagoa. A confiança de todo procedimento foi confirmada através de testes de recuperação. / An electrochemical procedure for palladium deposition on the inner of a graphite tube for permanent chemical modification and a cold vapor generation system for the determination of trace levels of mercury in water and sediment by atomic absorption spectrometry are proposed. The tubular electrochemical cell for the deposition of palladium was assembled on the original geometry of a graphite tube that operates as the working electrode. A stainless steel tube, positioned downstream from the working electrode, is used as the auxiliary electrode. The potential value applied on the graphite electrode is measured against a micro reference electrode (Ag/AgCl) inserted into the auxiliary electrode. Palladium solutions in acetate buffer (100 milimol L-1, pH=4.70), flowing at 0.5 mL min-1 for 60 min was used to perform the electrochemical deposition. A cold vapor generation system consist of a micro polyethylene reactor and gas-liquid separator flask, total volume of 4.0 mL, that is discarded after each sampling to avoid intercontamination of the samples. Volumes of 1.0 mL of reagent (2.0% m/v NaBH4 in 0.10 mol L-1 of NaOH) and 1.0 mL of reference or sample solutions in 0.25 mol L-1 of HNO3 are carried out to the reactor and gas-liquid separator by using a peristaltic pump. The mercury vapor is transported to the graphite tube electrochemically modified with argon flow (200 mL min-1) and pre-concentrated during 120 s. The detection limit obtained was 93 ng L-1 (n=20, 3δ). The performance of these system was tested for determination of mercury in potable and non-potable water and lake sediments. The reliability of the entire procedure was confirmed by recovery tests.
4

Metais presentes nas águas e em tecidos de peixes da represa Billings: uma avaliação temporal / Metals in water and fish tissue from Billings Dam: a temporal evaluation

Oliveira, Talita Aparecida de 19 December 2012 (has links)
A represa Billings é o maior reservatório de água que abastece o estado de São Paulo. Está localizada na bacia do Alto Tietê na região metropolitana de São Paulo, em uma área de proteção ambiental. Contudo, desde o início da sua inundação, vem sofrendo sérias agressões ambientais. Entre elas, o fluxo de entrada de água do rio Pinheiros, usado para controle de enchentes na região metropolitana de São Paulo. A constante entrada de contaminantes na represa se torna preocupante, considerando que, no seu entorno, há diferentes tipos de assentamentos, entre os quais de famílias de pescadores, que usam estas águas sem tratamentos convencionais para consumo doméstico e pesca artesanal para subsistência. Portanto, este estudo teve como objetivo realizar uma avaliação temporal dos níveis de metais presentes na água e em tecidos dos peixes da represa, correlacionando estes valores com o fluxo de entrada de água do rio Pinheiros e do índice pluviométrico na região. Durante o período de um ano, cerca de 800 indivíduos, dentre as principais espécies de peixes consumidas na região Geophagus brasiliensis (acará), Hoplias malabaricus (traíra), Tilapia rendalli (tilápia) e Astyanax ssp (lambari), de sete pontos de pesca, foram coletadas e analisados. Amostras de águas foram coletadas em 13 pontos sugeridos pelos pescadores locais. Considerando cada espécie de peixe analisada, os níveis de metais estão na mesma ordem de magnitude, independentemente da região de captura. Os níveis de Cr, em cerca de 60% dos acarás, 98% dos lambaris, 67% dos traíras e 100% de tilápia não atenderam ao limite estabelecido pela ANVISA. Cu e Hg, em todas as amostras atenderam aos limites estabelecidos pela legislação nacional. A inserção das águas do rio Pinheiros claramente afeta a qualidade da água da represa. As regiões mais contaminadas são: Pedreira, Margem do Bororé, Alvarenga, Barragem Taquacetuba, Casa Caída e Ilha do Biguá. Observou-se também que 100% de amostras não atendem ao limite estabelecido pelo CONAMA; para Cu, Mn, Ni, cerca de 50% não cumprem o limite estipulado para Cd e 20% para Zn. Em linhas gerais, observou-se que esta inserção altera todo o regime natural da represa, mas que ainda assim é possível absorver a contaminação recebida. / The Billings Dam is the largest reservoir of water that supplies in the state of São Paulo. It is part of the Alto Tiete basin, which is located in the metropolitan region of São Paulo in an environmentally protected area. In spite of that, since the beginning of its flooding, several environmental aggressions were observed. Among them the inflow of water from Pinheiros river, used to control floods in the metropolitan region of Sao Paulo .The constant input of contaminants in the dam becomes worrisome, considering that, in its surroundings, there are different kinds of settlements, among them families of fishermen, who use these waters without conventional treatments for domestic consumption and artisanal fishing for livelihood. Therefore, this study aimed to carry out a temporal evaluation of metal levels present in dam\'s water and fish tissue, correlating these values with the water input flow of Pinheiros River and pluviometric index in the region. During a period of one year, circa of 800 individuals among the main consumed fish species in the region Geophagus brasiliensis (acará), Hoplias malabaricus (traíra), Tilapia rendalli (tilápia) e Astyanax ssp (lambari), from seven fishing places were collected and analysed. It was also collected water from thirteen places chosen by local fishermen. Considering each fish specimen analyzed, the levels of metals are in the same order of magnitude regardless of the region of capture. The levels of Cr in circa of 62% of acarás, 98% of lambaris, 67% of traíras and 100% of tilapia do not meet the limit stipulated by ANVISA. Cu and Hg, in all samples meet the limits set by national legislation. The Pinheiros river water clearly affects the quality of dam\'s water. The most contaminated regions were: Pedreira, Margem do Bororé, Alvarenga, Barragem Taquacetuba, Casa Caída and Ilha do Biguá. It was observed that 100% of samples do not meet the limits established for water quality by CONAMA for Cu, Mn and Ni, 50% do not meet the limit for Cd and 20% for Zn . In general, we can observe the entry of to the waters of Pinheiros River during operation of the flotation system and even during the flood control changes the whole natural scheme of the dam, although the dam still manages to absorb the contamination that is received.
5

Metais presentes nas águas e em tecidos de peixes da represa Billings: uma avaliação temporal / Metals in water and fish tissue from Billings Dam: a temporal evaluation

Talita Aparecida de Oliveira 19 December 2012 (has links)
A represa Billings é o maior reservatório de água que abastece o estado de São Paulo. Está localizada na bacia do Alto Tietê na região metropolitana de São Paulo, em uma área de proteção ambiental. Contudo, desde o início da sua inundação, vem sofrendo sérias agressões ambientais. Entre elas, o fluxo de entrada de água do rio Pinheiros, usado para controle de enchentes na região metropolitana de São Paulo. A constante entrada de contaminantes na represa se torna preocupante, considerando que, no seu entorno, há diferentes tipos de assentamentos, entre os quais de famílias de pescadores, que usam estas águas sem tratamentos convencionais para consumo doméstico e pesca artesanal para subsistência. Portanto, este estudo teve como objetivo realizar uma avaliação temporal dos níveis de metais presentes na água e em tecidos dos peixes da represa, correlacionando estes valores com o fluxo de entrada de água do rio Pinheiros e do índice pluviométrico na região. Durante o período de um ano, cerca de 800 indivíduos, dentre as principais espécies de peixes consumidas na região Geophagus brasiliensis (acará), Hoplias malabaricus (traíra), Tilapia rendalli (tilápia) e Astyanax ssp (lambari), de sete pontos de pesca, foram coletadas e analisados. Amostras de águas foram coletadas em 13 pontos sugeridos pelos pescadores locais. Considerando cada espécie de peixe analisada, os níveis de metais estão na mesma ordem de magnitude, independentemente da região de captura. Os níveis de Cr, em cerca de 60% dos acarás, 98% dos lambaris, 67% dos traíras e 100% de tilápia não atenderam ao limite estabelecido pela ANVISA. Cu e Hg, em todas as amostras atenderam aos limites estabelecidos pela legislação nacional. A inserção das águas do rio Pinheiros claramente afeta a qualidade da água da represa. As regiões mais contaminadas são: Pedreira, Margem do Bororé, Alvarenga, Barragem Taquacetuba, Casa Caída e Ilha do Biguá. Observou-se também que 100% de amostras não atendem ao limite estabelecido pelo CONAMA; para Cu, Mn, Ni, cerca de 50% não cumprem o limite estipulado para Cd e 20% para Zn. Em linhas gerais, observou-se que esta inserção altera todo o regime natural da represa, mas que ainda assim é possível absorver a contaminação recebida. / The Billings Dam is the largest reservoir of water that supplies in the state of São Paulo. It is part of the Alto Tiete basin, which is located in the metropolitan region of São Paulo in an environmentally protected area. In spite of that, since the beginning of its flooding, several environmental aggressions were observed. Among them the inflow of water from Pinheiros river, used to control floods in the metropolitan region of Sao Paulo .The constant input of contaminants in the dam becomes worrisome, considering that, in its surroundings, there are different kinds of settlements, among them families of fishermen, who use these waters without conventional treatments for domestic consumption and artisanal fishing for livelihood. Therefore, this study aimed to carry out a temporal evaluation of metal levels present in dam\'s water and fish tissue, correlating these values with the water input flow of Pinheiros River and pluviometric index in the region. During a period of one year, circa of 800 individuals among the main consumed fish species in the region Geophagus brasiliensis (acará), Hoplias malabaricus (traíra), Tilapia rendalli (tilápia) e Astyanax ssp (lambari), from seven fishing places were collected and analysed. It was also collected water from thirteen places chosen by local fishermen. Considering each fish specimen analyzed, the levels of metals are in the same order of magnitude regardless of the region of capture. The levels of Cr in circa of 62% of acarás, 98% of lambaris, 67% of traíras and 100% of tilapia do not meet the limit stipulated by ANVISA. Cu and Hg, in all samples meet the limits set by national legislation. The Pinheiros river water clearly affects the quality of dam\'s water. The most contaminated regions were: Pedreira, Margem do Bororé, Alvarenga, Barragem Taquacetuba, Casa Caída and Ilha do Biguá. It was observed that 100% of samples do not meet the limits established for water quality by CONAMA for Cu, Mn and Ni, 50% do not meet the limit for Cd and 20% for Zn . In general, we can observe the entry of to the waters of Pinheiros River during operation of the flotation system and even during the flood control changes the whole natural scheme of the dam, although the dam still manages to absorb the contamination that is received.
6

DETERMINATION OF MERCURY IN <i>MAGICICADA</i>

HECKEL, PAMELA FUNDERBURG January 2007 (has links)
No description available.
7

Estratégias analíticas para determinação de espécies inorgânicas em medicamentos utilizados no tratamento de anemia ferropriva

Barbosa, Uenderson Araújo 28 September 2015 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-02-25T13:31:28Z No. of bitstreams: 1 Tese Uenderson Araujo Barbosa -final.pdf: 2006362 bytes, checksum: 7f8502d02bb06b7f75032fb7a79d79bc (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-05-10T17:54:24Z (GMT) No. of bitstreams: 1 Tese Uenderson Araujo Barbosa -final.pdf: 2006362 bytes, checksum: 7f8502d02bb06b7f75032fb7a79d79bc (MD5) / Made available in DSpace on 2016-05-10T17:54:24Z (GMT). No. of bitstreams: 1 Tese Uenderson Araujo Barbosa -final.pdf: 2006362 bytes, checksum: 7f8502d02bb06b7f75032fb7a79d79bc (MD5) / CAPES e CNPq / Neste trabalho foram propostas estratégias analíticas visando à avaliação toxicológica de metais e metaloides em medicamentos utilizados no tratamento da anemia ferropriva, empregando técnicas cromatográficas e não cromatográficas. Na primeira parte desta tese determinou-se chumbo nos medicamentos aplicando espectrometria de absorção atômica com atomização eletrotérmica (ETAAS). O preparo da amostra foi realizado fazendo uso de digestão ácida em bloco digestor com sistema de refluxo “dedo frio” usando 3 mL de HNO3 (69% v/v) e 1 mL de H2O2 (30% v/v). Foram otimizadas as temperaturas de pirólise e atomização usando uma mistura de paládio e magnésio como modificador químico convencional, obtendo-se 1100ºC e 2000ºC para pirólise e atomização, respectivamente. Com uma massa característica de 21,3 pg e 0,25 e 0,82 µg L-1, para os limites de detecção (LD) e de quantificação (LQ), respectivamente. A precisão, expressa pelo desvio padrão relativo de 5.92% para uma amostra com concentração de chumbo igual a 2,98 µg g-1. A exatidão foi estimada por comparação entre os resultados obtidos por ETAAS e espectrometria de massas com plasma indutivamente acoplado (ICP-MS). As concentrações de chumbo nas amostras variaram entre 0,096 e 7,068 µg g-1. Na segunda parte deste trabalho, foi efetuada a determinação de mercúrio através de amostragem em suspensão e espectrometria de absorção atômica com alta resolução e fonte contínua com geração de vapor frio (HR-CS CVAAS). As condições ótimas de preparo das suspensões (1,5 mol L-1 de HCl, 1,25% (m/v) de tioureia e 15 minutos de sonicação) foram otimizadas por planejamento fatorial completo. Os limites de detecção e quantificação foram 0,63 ng g-1 e 2,11 ng g-1, respectivamente. O desvio padrão relativo para avaliação da precisão foi calculado usando duas amostras com concentrações 4,82 e 9,61 ng g-1 com resultados 10,89 e 6,84%, respectivamente. Foi estimada a possível perda de mercúrio durante o procedimento proposto e a exatidão, mediante testes de adição e recuperação, variando entre 85,0 e 106,0%. As concentrações de mercúrio ficaram entre 3,17 e 34,86 ng g-1. A terceira parte deste trabalho descreve a determinação de macro e microelementos e o estudo in vitro da bioacessibilidade de ferro em medicamentos usados no tratamento da anemia ferropriva. Foi escolhida a espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES) como técnica analítica de medida. Foi efetuada digestão ácida para tratamento das amostras e o método foi validado, demonstrando boa sensibilidade, com limites de quantificação (mg L-1) 0,52 para Ca, 0,14 para K, 0,03 para Mg, 0,07 para Mn, 0,40 para Na, 0,36 para P e 0,24 para Zn. A precisão do método foi reconhecida mediante experimentos repetitivos intradia e interdia com resultados abaixo de 20%. Durante estudo da exatidão, testes de adição e recuperação foram executados em diferentes concentrações com resultados entre 81,85 e 114,97%. A robustez do plasma foi calculada mediante uma razão entre as linhas iônica e atômica de magnésio, Mg(II)/Mg(I) e os resultados, mediante análise componentes principais (PCA) e análise por agrupamentos hierárquicos (HCA). O estudo de bioacessibilidade in vitro de Fe demonstrou que alguns medicamentos são melhores bioacessíveis, sendo portanto, mais recomendados para o tratamento da anemia, comprovando dados da literatura farmacológica. Na quarta parte deste trabalho descreve-se o estudo da determinação e especiação simultânea de arsênio e cromo por 11 cromatografia líquida de alta eficiência acoplada à ICP-MS (HPLC-ICP-MS). A determinação total de arsênio e cromo foi realizada usando uma digestão ácida em forno de micro-ondas, uma mistura de 4 mL HNO3 (69% v/v) e 1 mL de H2O2 (30% v/v) e análise por ICP-MS. Para o estudo de especiação foi elaborado um estudo com três possíveis procedimentos para extração das espécies, sendo selecionado um procedimento com água a 80ºC por 30 minutos em energia de micro-ondas. Usando uma fase móvel contendo 1,0 mM de hidróxido de tetrabutilamônio (TBAH), 0,7 mM de ácido etilenodiaminotetracético (EDTA) e 5% de metanol (v/v) em pH 7,2 foi possível separar as espécies presentes com tempo de retenção de 5 minutos com separação de As(III), As(V), Cr(III) e Cr(VI), com limites de detecção de 0,002, 0,003, 0,140 e 0,042 µg g-1, respectivamente. A exatidão do método foi avaliada conforme testes de adição e recuperação, entre 80,64 e 109,36%. O método foi aplicado em amostras do Brasil e Espanha, com concentrações entre 0,1-1,3 e 0,18-62,27 µg g-1 para As e Cr, respectivamente. / In this thesis work analytical strategies have been proposed for toxicological assessment of metals and metalloids in medicines used to treat iron deficiency anemia, using chromatographic and non-chromatographic techniques. In the first part of this thesis, lead was determined in drugs using electrothermal atomic absorption spectrometry (ETAAS). Sample preparation was performed using acid digestion in digester block with reflux system "cold finger" using 3 mL of HNO3 (69% v / v) and 1 mL of H2O2 (30% v / v). Pyrolysis and atomization temperatures were optimized using a mixture of palladium and magnesium as conventional chemical modifier, yielding 1100°C and 2000°C for pyrolysis and atomization, respectively. With a characteristic mass of 21.3 pg and 0.25 and 0.82 µg g-1, for limit of detection (LOD) and limit of quantification (LOQ), respectively. The accuracy, expressed as relative standard deviation was 5.92% for a sample with lead concentration of 2.98 µg g-1. The accuracy was evaluated by comparing the results obtained by ETAAS and inductively coupled plasma mass spectrometry (ICP-MS). Lead concentrations found in samples ranged between 0.096 and 7.068 µg g-1. In the second part of this work, the determination of mercury using slurry sampling and high resolution continuous source cold vapor atomic absorption spectroscopy (HR-CS CVAAS) was performed. The optimum conditions for preparation of slurries (1.5 mol L-1 HCl, 1.25% (w / v) thiourea and 15 minutes sonication) were optimized using a two level full factorial design. The limits of detection and quantification were 0.63 ng g-1 and 2.11 ng g-1, respectively. The relative standard deviation for accuracy evaluation was calculated using two samples with concentrations 4.82 and 9.61 ng g-1 from which was obtained as results 10.89 and 6.84%, respectively. The possible loss of mercury was evaluated for the proposed procedure and the accuracy was studied by addition/recovery test, with recoveries ranging from 85.0 to 106.0%. Mercury concentrations ranged between 3.17 and 34.86 ng g-1. The third part of this work describes the determination of macro and micro elements and the in vitro study of iron bioaccessibility in medicines used to treat iron deficiency anemia. It was used inductively coupled plasma optical emission spectrometry (ICP OES) measured as an analytical technique. Acid digestion treatment was conducted to the samples and the method was fully validated by demonstrating good sensitivity with quantification limits (mg L-1) 0.52 for Ca, 0.14 for K, 0.03 for Mg, 0.07 for Mn, 0.40 for Na, 0.36 for P and 0.24 for Zn. The precision of the method was evaluated by intraday and interday repetitive experiments with results below 20%. During accuracy evaluation, addition/recovery tests were performed at different concentrations with results between 81.85 and 114.97%. The robustness of plasma was evaluated by a ratio between magnesium atomic and ionic lines, Mg(II)/Mg(I). The results were evaluated by multivariate analysis tools, principal component analysis (PCA) and hierarchical cluster analysis (HCA). The study of in vitro bioaccessibility of Fe showed that some drugs are better bioaccessible, being therefore more recommended for anemia treatment, confirming data of pharmacological literature. The fourth part of this work describes the simultaneous determination of arsenic and chromium speciation using high-performance liquid chromatography coupled to ICP-MS (HPLC-ICP- MS). The total arsenic and chromium determination was carried out using an acid digestion in microwave oven, using a mixture of 4 mL HNO3 (69% v / v) 9 and 1 mL of H2O2 (30% v / v) and analyzed by ICP-MS. For speciation, a study was performed with three possible procedures for extraction of species, being employed a procedure with water at 80 °C for 30 minutes in microwave energy. Using a mobile phase containing 1.0 mM tetrabutylammonium hydroxide (TBAH), 0.7 mM ethylenediaminetetraacetic acid (EDTA) and 5% methanol (v / v) under pH 7.2 was possible the separation of the species present with retention time of 5 minutes with separation of As(III) As(V), Cr(III) and Cr(VI), with a LOD of 0.002, 0.003, 0.140 and 0.042 µg g-1, respectively. The accuracy was assessed using addition/recovery tests, ranging between 80.64 and 109.36%. The method was applied in samples from Brazil and Spain.

Page generated in 0.0134 seconds